2015 mvp bro - j-drain.com · mvp i mvp ii 292 s. main st., suite 200 alpharetta, ga 30009...

2
PHYSICAL PROPERTIES [email protected] www.j-drain.com Fabric 2 2 2 2 Flow (ASTM D-4491) 140 gpm/ft (5704 lpm/m ) 95 gpm/ft (3870 lpm/m ) CBR Puncture (ASTM D-6241) 250 lbs. (1.11 kN) 225 lbs. (1.0 kN) AOS (ASTM D-4751) 70 U.S. Sieve (.212 mm) 50 U.S. Sieve (.30 mm) Grab Tensile (ASTM D-4632) 100 lbs. (.45 kN) 110 lbs. (.495 kN) Mullen Burst (ASTM D-3786) 210 PSI (1447 KpA) 90 PSI (620 KpA) U.V. Resistance (ASTM D-4355) 70% @500 hrs. 70% @500hrs. Core 2 Compressive Strength (ASTMD-1621) 12,500 psf (598 kN/m ) Thickness (ASTM-1777) 1 In. (2.54 cm.) In-Plane Flow (ASTMD-4716) 30 gpm/ft width (372 lpm/m) (Q&518 psf & Hydraulic gradient = .1) Roll Weight: 38 or 68 lbs. (17 or 30.5 kgs.) Roll Width: 6”,12”,& 18” (15,30, & 45 cm.) Roll Length: 165 ft. (50.29 meters) Roll Grey Spun-Bonded Black Non-Woven The information contained herein is believed by JDR Enterprises, Inc. to be accurate and is offered solely for the customer’s consideration, investigation and verification. Determination of suitability for use is the responsibility of the user. JDR’s Limitiations, Limited Warranty, & Disclaimer along with Standard Terms & Conditions apply. See www.j-drain.com for more info. Limitations: J-DRain is resistant to chemicals in normal soil environments. However, some reagents may affect the performance of J-DRain. A JDR representative should be contacted for further information to determine the suitability of use of J-DRain in unusual soil environments. J-DRain should be limited to its exposure to ultra-violet sunlight. J-DRain should be backfilled or covered within seven days of installation. Disclaimer: All information, drawings and specifications are based on the latest published information at the time of printing. JDR reserves the right to make changes due to manufacturing improvements and engineering at any time. All physical properties are minimum average roll values (MARV). Standard variations of 10% in mechanical properties and 15% in hydraulic properties are normal. MVP I MVP II 292 S. Main St., Suite 200 Alpharetta, GA 30009 (800) 843-7569 (770) 442-1461 Enterprises, Inc. LANDSCAPE GOLF COURSES ATHLETIC FIELDS APPLICATIONS NOTE: JDRAIN MVP-12 is placed horizontally across playing field and sloped to sideline trenches thus eliminating cross field trenching. TYPICAL SYNTHETIC TURF DETAIL J-DRain MVP-12 GRAVEL TURF AND PAD JDRAIN MVP-6 12” MIN. 2”-3” WIDTH SAND BACK FILL TYPICAL NATURAL TURF DETAIL NOTE: JDRAIN MVP-6 is placed vertically in narrow trenches and sloped to sidelines. Narrow trenches are less intrusive to playing field. MVP I MVP II BRO-MVPCS-0316 Maximum Velocity & Perfomance MVP ENDOUT T CONNECTOR (6” only) END CAP SPLICE JDRAIN MVP is a 3-dimensional, high-flow, polyethylene/polypropylene blend drainage core which is wrapped with either non-woven filter fabric (MVP I) or spun-bounded filter fabric(MVP II). It is designed to retain soil particles while allowing water to pass through the drain core for easy removal of water. JDRAIN MVP-6 is placed vertically in narrow, less intrusive trenches and sloped to collection drains in natural turf applications. JDRAIN MVP-12 is placed horizontally across the field toward the sideline trench in synthetic turf applications. ENDZONE 6 IN. COLLECTOR PIPE 1 % SLOPE 45° JDRAIN MVP-6 or MVP-12 (Laterals to be placed 12’ - 15’ on center) 1 % SLOPE TO DISCHARGE ENDZONE 6 IN. SLOPE SLOPE COLLECTOR PIPE 1 % SLOPE TO DISCHARGE 1 % SLOPE CROWN

Upload: others

Post on 22-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 2015 MVP bro - j-drain.com · MVP I MVP II 292 S. Main St., Suite 200 Alpharetta, GA 30009 Enterprises, Inc. (800) 843-7569 (770) 442-1461 LANDSCAPE GOLF COURSES ATHLETIC FIELDS APPLICATIONS

PHYSICAL PROPERTIES

[email protected] www.j-drain.com

Fab

ric

2 2 2 2Flow (ASTM D-4491) 140 gpm/ft (5704 lpm/m ) 95 gpm/ft (3870 lpm/m )

CBR Puncture (ASTM D-6241) 250 lbs. (1.11 kN) 225 lbs. (1.0 kN)

AOS (ASTM D-4751) 70 U.S. Sieve (.212 mm) 50 U.S. Sieve (.30 mm)

Grab Tensile (ASTM D-4632) 100 lbs. (.45 kN) 110 lbs. (.495 kN)

Mullen Burst (ASTM D-3786) 210 PSI (1447 KpA) 90 PSI (620 KpA)

U.V. Resistance (ASTM D-4355) 70% @500 hrs. 70% @500hrs.

Cor

e 2Compressive Strength (ASTMD-1621) 12,500 psf (598 kN/m )

Thickness (ASTM-1777) 1 In. (2.54 cm.)In-Plane Flow (ASTMD-4716) 30 gpm/ft width (372 lpm/m) (Q&518 psf & Hydraulic gradient = .1)

Roll Weight: 38 or 68 lbs. (17 or 30.5 kgs.)Roll Width: 6”,12”,& 18” (15,30, & 45 cm.) Roll Length: 165 ft. (50.29 meters)R

oll

Grey Spun-BondedBlack Non-Woven

The information contained herein is believed by JDR Enterprises, Inc. to be accurate and is offered solely for the customer’s consideration, investigation and verification. Determination of suitability for use is the responsibility of the user. JDR’s Limitiations, Limited Warranty, & Disclaimer along with Standard Terms & Conditions apply. See www.j-drain.com for more info. Limitations: J-DRain is resistant to chemicals in normal soil environments. However, some reagents may affect the performance of J-DRain. A JDR representative should be contacted for further information to determine the suitability of use of J-DRain in unusual soil environments. J-DRain should be limited to its exposure to ultra-violet sunlight. J-DRain should be backfilled or covered within seven days of installation. Disclaimer: All information, drawings and specifications are based on the latest published information at the time of printing. JDR reserves the right to make changes due to manufacturing improvements and engineering at any time. All physical properties are minimum average roll values (MARV). Standard variations of 10% in mechanical properties and 15% in hydraulic properties are normal.

MVP I MVP II

292 S. Main St., Suite 200 Alpharetta, GA 30009

(800) 843-7569 (770) 442-1461Enterprises, Inc.

LANDSCAPE

GOLF COURSES

ATHLETIC FIELDS

APPLICATIONS

NOTE: J•DRAIN MVP-12 is placed horizontally across playing fieldand sloped to sideline trenches thus eliminating cross fieldtrenching.

TYPICAL SYNTHETIC TURF DETAIL

J-DRain MVP-12

GRAVEL

TURF AND PAD

J•DRAIN MVP-6

12”MIN.

2”-3”WIDTH

SAND BACK FILL

TYPICAL NATURAL TURF DETAIL

NOTE: J•DRAIN MVP-6 is placed vertically in narrow trenches and sloped to sidelines. Narrowtrenches are less intrusive to playing field.

MVP I MVP II

BRO-MVPCS-0316

Maximum Velocity & Perfomance

MVP

ENDOUT

T CONNECTOR (6” only)

END CAP

SPLICE

J•DRAIN MVP is a 3-dimensional, high-flow, polyethylene/polypropylene blend drainage core which is wrapped with either non-woven filter fabric (MVP I) or spun-bounded filter fabric(MVP II). It is designed to retain soil particles while allowing water to pass through the drain core for easy removal of water. J•DRAIN MVP-6 is placed vertically in narrow, less intrusive trenches and sloped to collection drains in natural turf applications. J•DRAIN MVP-12 is placed horizontally across the field toward the sideline trench in synthetic turf applications.

EN

DZ

ON

E

6 IN. COLLECTOR PIPE

1 %

SLO

PE

45°

J•DRAIN MVP-6 or MVP-12(Laterals to be placed 12’ - 15’ on center)

1 % SLOPE TO DISCHARGE

EN

DZ

ON

E

6 IN.

SLO

PE

SLO

PE

COLLECTOR PIPE

1 % SLOPE TO DISCHARGE

1 % SLO

PE

CROWN

Page 2: 2015 MVP bro - j-drain.com · MVP I MVP II 292 S. Main St., Suite 200 Alpharetta, GA 30009 Enterprises, Inc. (800) 843-7569 (770) 442-1461 LANDSCAPE GOLF COURSES ATHLETIC FIELDS APPLICATIONS

[email protected] www.j-drain.com

Synthetic Turf Applications

Natural Turf Applications

292 S. Main St., Suite 200 Alpharetta, GA 30009