2016 / 17 price list

76
PRICE LIST » COMMITTED TO PEOPLE; COMMITTED TO THE FUTURE « 2016 / 17 Airconditioning systems

Upload: others

Post on 21-Nov-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

PRICE LIST

» COMMIT TED TO PEOPLE; COMMIT TED TO THE FUTURE «

2016 / 17Airconditioning systems

TERMS OF BUSINESS

GeneralAs far as nothing else has been declared, the general terms of business and the agreed

purchase conditions including the sales discounts are valid. Arrangements that differ from our

terms are only valid on condition that we confirm this explicit and in writing.

JurisdictionJurisdiction for both partners is the «Landes- als Handelsgericht» Graz. Austrian law is valid.

QuotationOur prices are quoted inclusively normal packaging ex loading platform of the forwarding

agency Gebrüder Weiss Maria Lanzendorf, without loading. Costs incurred due to special requests

are met by the purchaser. Incoterms are valid in the version of 2010. Separate agreements for

pricing are noted on the purchase conditions.

Passing of the riskThe risk goes over the purchaser as soon as the goods have left the loading platform on which

they had been prepared for collection. The risk of loading is taken by the purchaser.

Take-over of the goodsWhen taking over the goods, the forwarding agency organised by the purchaser or the collector

has the duty to check the delivery according to the order. Any damages noticed on the carton

box or on the unit itself have to be noted on the delivery note when taking over and immediately

reported to the forwarding agency and Air-Cond. Latent defects have to be notified in Austria

within 7 days and in export countries 10 days from date of collection, otherwise claims/liability

will not be accepted by the insurance company. In case of transport damages a written reclamation

for visible damages is necessary immediately, at the latest within 7 days.

Reservation of ownershipThe delivered or otherwise transferred goods remain our property until full payment.

Wrong deliveriesAll costs that result from wrong deliveries cannot be asserted

Material warrantyClaims for material warranty can be asserted from the purchaser within 36 months from date

of delivery and date of invoice using our provided form for material warranty claims and against

returning the faulty part if we ask for this. The material warranty only contains the replacing of

spare parts ex our warehouse. We clearly mention that the material warranty does not include

the refund of costs for wages, travel costs etc. Condition for accepting the material warranty

claim is the proper installation by a specialist according to the TOSHIBA installation rules,

permitted operating conditions and the periodical service following the TOSHIBA maintenance

guidelines. In case of an improper installation or non-compliance of the permitted operation

conditions and maintenance guidelines resp. wrong dimensioning, claims for material warranty

will be refused.

Advanced Material warranty for VRF-products: Under the assumption that there is a VRF project,

a commissioning report has been completed and a AIRS design is concerned, there is the

possibility of extending the period of material warranty from 3 to 5 years, after checked all the

documents. This is confirmed by a certificate.

Cancellation feeFor the cancellation of orders we allow us to charge in general the amount of € 60,--. When

receiving the cancellation after the preparation of the goods and invoice or after issuing export

documents we charge the amount of € 120,--. In case of already delivered goods all costs

incurred of removal, preparation of papers, any transportation costs and expenses for restocking

will be charged.

Delay in payment / Default interestsIn case of a delay in payment by the principal, we reserve the right to retain all future services

till full settlement of the delayed payment. As far as this delay is not limited to a small amount

Air-Cond is entitled for all subsequent orders, which already have been confirmed, to demand

payment in advance.

On delay the client has to pay on the amount due interests to the extent of 8% points on top

of the base rate annually.

Any rights of Air-Cond to request additional delay damages shall remain unaffected.

Export declaration (valid for Non-EU member states)The purchaser commits himself to send us the export declaration (customs‘ confirmation that

the goods left the EU) within 14 days after the collection under registered mail. In case of

omission we charge 20% VAT, customs duty and a fine of the customs authorities.

Validity of the price list: 1st March 2016 until 28th February 2017The price list is subject to the general terms of business of company Air-Cond Klimaanlagen-Handelsgesellschaft m.b.H in the version of 25th February 2016.

Subject to changes without notice! All specifications, model names and figures are subject to typing and printing errors.

LIGHT COMMERCIAL RAV overview - indoor units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Hi-wall (DI, S-DI). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Compact 4-way cassette (DI, S-DI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Standard 4-way cassette (DI, S-DI). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20-21Ceiling (DI, S-DI). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Standard Duct (DI, S-DI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Ultra-slim Duct (DI, S-DI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24High-pressure Duct (DI BIG) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Valve kit (DI, S-DI, DI BIG). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25RAV split solutions for one temperature zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Joints for RAV Multi installations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Air Curtain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Compatible outdoor units to air curtains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

COMMERCIAL Indoor units range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30-31VRF systems overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32SMMS-i /SMMS-e outdoor units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33-35MiNi SMMS-i / MiNi SMMS-e . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36SHRM-i outdoor units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37SHRM-i refrigerant distributor sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37VRF Hi-wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38-39VRF Ceiling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40VRF Duct . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41-43VRF Cassette . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44-46VRF Chassis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46VRF Console/Floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47VRF Valve kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Ventilation system with heat recovery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49VRF Hot water module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49VRF Joints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

CONTROLS Locale Remote Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53Central Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54Building Management Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55Control options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56Special accessories RAV/VRF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56TOSHIBA service programs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Airpatrol / Intesis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

ESTIA ESTIA series 4 outdoor units / Hydro Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58ESTIA HiPower outdoor units / Hydro Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59ESTIA hot water tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60ESTIA accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

RESIDENTIAL RAS overview - indoor units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6MIRAI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7AvAnt Inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Suzumi Plus. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Super Daiseikai 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Inverter Multi systems indoor units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Accessories Multi. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Inverter Multi systems outdoor units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Overview of basic features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14-15

ADDITIONAL INFORMATION Additional information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62-63Information for air conditioning at low outside temperatures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64-65Power consumption and hedging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66-67Sound power / sound pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68-69 VRF performance tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70-71Measuring conditions for TOSHIBA air-conditioners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72Glossar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

6 I TOSHIBA

P R I C E L I S T – RESIDENTIALR

ESID

ENTI

AL

Model type size 10 13 16 18 22

HI-WALL

AvAnt

RAS-xxxSKV-E7

MIRAI

RAS-xxBKV-ERAS-xxBKVG-E

Suzumi Plus

RAS-BxxN3KV2-E1

Super Daiseikai 8

RAS-xxG2KVP-E

CHASSIS

Console

RAS-BxxUFV-E(1)

BUILT-IN UNITS

60×60 4-way cassette

RAS-MxxSMUV-E

Duct unit

RAS-MxxG3DV-E

Indoor units

TOSHIBA I 7

RES

IDEN

TIA

L

TypeCapacity (kW) Energy label Efficiency Dimensions

(H × W × D) (mm)

Power consumption (kW) Sound power level (dB(A)) ❄ /

Single price Set price

❄ ❄ / SEER SCOP ❄ excl. VAT (EUR)

MIRAI (Standard infrared remote control included)

RAS-10BKV-E 2,50(0,67 - 3,10)

3,20(0,70 - 3,90)

A+ / A+ 5,60 4,00293 × 798 × 230

0,16 - 1,19 0,15 - 1,0655 / 56 270,–

900,–RAS-10BAV-E 530 × 660 × 240 63 / 65 630,–

RAS-13BKV-E 3,10(0,75 - 3,50)

3,70(0,70 - 4,50)

A+ / A+ 5,70 4,00293 × 798 × 230

0,18 - 1,33 0,15 - 1,2456 / 57 270,–

980,–RAS-13BAV-E 530 × 660 × 240 63 / 65 710,–

RAS-16BKV-E 4,40(1,10 - 5,00)

5,20(1,00 - 6,20)

A+ / A 5,80 3,80293 × 798 × 230

0,26 - 1,90 0,19 - 1,8160 / 60 305,–

1.275,–RAS-16BAV-E 550 × 780 × 290 64 / 65 970,–

MIRAI R410A‘‘CLASSIC‘‘-Model

TypeCapacity (kW) Energy label Efficiency Dimensions

(H × W × D) (mm)

Power consumption (kW) Sound power level (dB(A)) ❄ /

Single price Set price

❄ ❄ / SEER SCOP ❄ excl. VAT (EUR)

MIRAI (Standard infrared remote control included)

RAS-10BKVG-E 2,50(067 - 3,10)

3,20(0,70 - 3,90)

A+ / A+ 5,60 4,00293 × 798 × 205

0,16 - 1,19 0,15 - 1,0655 / 56 270,–

900,–RAS-10BAVG-E 530 × 660 × 240 63 / 65 630,–

RAS-13BKVG-E 3,10(0,75 - 3,50)

3,60(0,70 - 4,50)

A+ / A+ 5,70 4,00293 × 798 × 230

0,18 - 1,33 0,15 - 1,2456 / 57 270,–

980,–RAS-13BAVG-E 530 × 660 × 240 63 / 65 710,–

RAS-16BKVG-E 4,60(1,10 - 5,30)

5,40(1,00 - 6,50)

A++ / A+ 6,10 4,20293 × 798 × 230

0,26 - 1,80 0,16 - 1,9060 / 60 305,–

1.275,–RAS-16BAVG-E 550 × 780 × 290 64 / 65 970,–

❄ Cooling Heating

Accessories

Type Single price excl. VAT (EUR)

818F0023 Optional filter strips for the MIRAI series 23,–

RB-RXS30-E Optional infrared remote control including weekly timer and 8 ° C frost protection function 75,–

RBC-Combi Control Control of the main functions via SMS or an app (for iOS and Android) as on / off, mode, temperature, fan speed and alarm in case of power failureor too high / too low temperature (Sim card required)

550,–

AP-IR-WIFI-1 WIFI control the air conditioning via smartphones (for iOS and Android), tablet or PC 275,–

MIRAI R32‘‘CLASSIC‘‘-Model

■ Modern, sleek design

■ Energy label A+

■ Very quiet operation

■ Refrigerant R32

■ Modern, sleek design

■ Energy label A+

■ Very quiet operation

8 I TOSHIBA

P R I C E L I S T – RESIDENTIALR

ESID

ENTI

AL

TypeCapacity (kW) Energy label Efficiency Dimensions

(H × W × D) (mm)

Power consumption (kW) Sound power level (dB(A)) ❄ /

Single price Set price

❄ ❄ / SEER SCOP ❄ excl. VAT (EUR)

Suzumi Plus (Standard infrared remote control included)

RAS-B10N3KV2-E1 2,50(1,10 - 3,00)

3,20(0,90 - 4,80)

A++ / A+ 6,70 4,30275 × 790 × 217

0,25 - 0,91 0,19 - 1,4053 / 54 365,–

1.025,–RAS-10N3AV2-E1 550 × 780 × 290 61 / 62 660,–

RAS-B13N3KV2-E1 3,50(1,10 - 4,05)

4,20(1,00 - 5,30)

A++ / A+ 6,50 4,00275 × 790 × 217

0,26 - 1,55 0,19 - 1,6454 / 55 395,–

1.195,–RAS-13N3AV2-E1 550 × 780 × 290 63 / 65 800,–

RAS-B16N3KV2-E1 4,50(0,80 - 5,00)

5,50(0,90 - 6,90)

A++ / A 6,10 3,90275 × 790 × 217

0,15 - 1,72 0,15 - 1,9860 / 60 435,–

1.420,–RAS-16N3AV2-E 550 × 780 × 290 64 / 65 985,–

RAS-18N3KV2-E1 5,00(1,10 - 6,00)

5,80(0,80 - 6,30)

A++ / A+ 7,00 4,10320 × 1050 × 229

0,18 - 2,00 0,14 - 1,7059 / 59 450,–

1.685,–RAS-18N3AV2-E 550 × 780 × 290 64 / 65 1.235,–

RAS-B22N3KV2-E1 6,00(1,20 - 6,70)

7,00(1,00 - 7,50)

A++ / A+ 6,50 4,00320 × 1050 × 229

0,20 - 2,65 0,18 - 2,2160 / 60 545,–

1.895,–RAS-22N3AV2-E 550 × 780 × 290 65 / 65 1.350,–

Accessories

Type Single price excl. VAT (EUR)

43T09485 Panel in silver, compatible with Suzumi Plus size 10-16 55,–

43T09486 Panel in silver, compatible with Suzumi Plus size 18, 22 65,–

818F0023 Optional filter strips for the Avant series 23,–

818F0036 Replacement filter strips for the Suzumi Plus series 30,–

RB-RXS30-E Optional infrared remote control including weekly timer and 8 ° C frost protection function 75,–

RBC-Combi Control Control of the main functions via SMS or an app (for iOS and Android) as on / off, mode, temperature, fan speed and alarm in case of power failureor too high / too low temperature (Sim card required)

550,–

AP-IR-WIFI-1 WIFI control the air conditioning via smartphones (for iOS and Android), tablet or PC 275,–

TCB-IFCB5-PE P.C. board for external on / off of air conditioner 50,–

Suzumi Plus‘‘COMFORT‘‘-Model

■ New design with clean lines

■ Compact design with lower unit depth

■ Optional infrared remote control including weekly timer and 8 ° C frost protection function

❄ Cooling Heating

TypeCapacity (kW) Energy label Efficiency Dimensions

(H × W × D) (mm)

Power consumption (kW) Sound power level (dB(A)) ❄ /

Single price Set price

❄ ❄ / SEER SCOP ❄ excl. VAT (EUR)

AvAnt Inverter (Standard infrared remote control included)

RAS-107SKV-E7 2,50(1,20 - 3,00)

3,20(0,90 - 3,50)

A / A 5,10 3,80275 × 790 × 205

0,29 - 1,05 0,21 - 0,9755 / 56 260,–

850,–RAS-107SAV-E6 530 × 660 × 240 63 / 65 590,–

RAS-137SKV-E7 3,15(1,20 - 3,60)

3,60(0,95 - 4,00)

A / A 5,10 3,80275 × 790 × 205

0,28 - 1,50 0,21 - 1,1856 / 57 260,–

940,–RAS-137SAV-E6 530 × 660 × 240 63 / 65 680,–

RAS-167SKV-E7 4,40(1,10 - 5,00)

5,20(1,00 - 6,20)

A+ / A 5,80 3,80275 × 790 × 205

0,26 - 1,90 0,19 - 1,8160 / 60 295,–

1.220,–RAS-167SAV-E5 550 × 780 × 290 64 / 65 925,–

AvAnt Inverter‘‘CLASSIC‘‘-Model

■ Optional infrared remote control including weekly timer and 8 ° C frost protection function

■ As long as stock lasts

TOSHIBA I 9

RES

IDEN

TIA

L

TypeCapacity (kW) Energy label Efficiency Dimensions

(H × W × D) (mm)

Power consumption (kW) Sound power level (dB(A)) ❄ /

Single price Set price

❄ ❄ / SEER SCOP ❄ excl. VAT (EUR)

Super Daiseikai 8 (Infrared remote control included)

RAS-10G2KVP-E 2,50(0,55 - 3,50)

3,20(0,45 - 5,80)

A+++/A+++ 9,10 5,20293 x 831 x 270

0,11 - 0,90 0,09 - 1,6557 / 58 535,–

1.730,–RAS-10G2AVP-E 630 x 800 x 300 61 / 61 1.195,–

RAS-13G2KVP-E 3,50(0,63 - 4,10)

4,00(0,65 - 6,30)

A+++/A+++ 8,90 5,10293 x 831 x 270

0,17 - 1,10 0,14 - 1,8058 / 59 565,–

1.905,–RAS-13G2AVP-E 630 x 800 x 300 63 / 64 1.340,–

RAS-16G2KVP-E 4,50(0,63 - 5,00)

5,50(0,65 - 6,80)

A++/A++ 7,30 4,60293 x 831 x 270

0,17 - 1,75 0,14 - 2,1259 / 60 640,–

2.435,–RAS-16G2AVP-E 630 x 800 x 300 64 / 64 1.795,–

❄ Cooling Heating

Accessories

Type Single price excl. VAT (EUR)

RBC-Combi Control Control of the main functions via SMS or an app (for iOS and Android) as on / off, mode, temperature, fan speed and alarm in case of power failureor too high / too low temperature (Sim card required)

550,–

AP-IR-WIFI-1 WIFI control the air conditioning via smartphones (for iOS and Android), tablet or PC 275,–

TCB-IFCB5-PE P.C. board for external on / off of air conditioner 50,–

Super Daiseikai 8‘‘PREMIUM‘‘-Model

■ PREMIUM model with excellent efficiency values, A+++

■ Elegant design with color LED and high-quality panel surface

■ Powerful filter system including plasma filter and Super ionizer

■ Convenient infrared remote control with weekly timer, 8 ° C frost protection function and many wellbeing functions

■ Very quiet

A+ + +

10 I TOSHIBA

P R I C E L I S T – RESIDENTIALR

ESID

ENTI

AL

TypeCapacity (kW) Energy label Efficiency Dimensions

(H × W × D) (mm)

Power consumption (kW) Sound power level (dB(A)) ❄ /

Single price Set price

❄ ❄ / SEER SCOP ❄ excl. VAT (EUR)

Console (Infrared remote control included)

RAS-B10UFV-E(1) 2,50(1,10 - 3,10)

3,20(1,00 - 4,80)

A++ / A+ 6,60 4,00600 × 700 × 220

0,23 - 0,82 0,18 - 1,4054 / 54 850,–

1.510,–RAS-10N3AV2-E1 550 × 780 × 290 59 / 60 660,–

RAS-B13UFV-E(1) 3,50(1,10 - 4,10)

4,20(1,00 - 5,40)

A++ / A 6,20 3,90600 × 700 × 220

0,23 - 1,35 0,18 - 1,7055 / 55 930,–

1.730,–RAS-13N3AV2-E1 550 × 780 × 290 61 / 63 800,–

RAS-B18UFV-E1 5,00(1,00- 5,70)

5,80(1,10 - 6,30)

A+ / A 5,70 3,80600 × 700 × 220

0,20 - 1,95 0,20 - 2,2060 / 60 1.120,–

2.355,–RAS-18N3AV2-E 550 × 780 × 290 64 / 64 1.235,–

❄ Cooling ● Heating

Accessories

Type Single price excl. VAT (EUR)

818F0036 Replacement filter strips for console 30,–

RB-RXS30-E Optional infrared remote control including weekly timer and 8 ° C frost protection function for indoor unit models in E1 75,–

RBC-Combi Control Control of the main functions via SMS or an app (for iOS and Android) as on / off, mode, temperature, fan speed and alarm in case of power failureor too high / too low temperature (Sim card required)

550,–

AP-IR-WIFI-1 WIFI control the air conditioning via smartphones (for iOS and Android), tablet or PC 275,–

TCB-IFCB5-PE P.C. board for external on / off of air conditioner 50,–

Console‘‘COMFORT‘‘-Model

■ Bi-flow console with variable possibilities of air outlet

■ Floor-heating-effect

■ Large radial fan for extra quiet operation

TOSHIBA I 11

RES

IDEN

TIA

L

TypeCapacity (kW) Efficiency Dimensions

(H × W × D) (mm)

Sound power level (dB(A)) ❄ /

Single priceexcl. VAT (EUR)

❄ SEER SCOP

Suzumi Plus Hi-wall indoor units (Standard infrared remote control included)

RAS-B10N3KV2-E1 2,50 (1,10 - 3,00) 3,20 (0,90 - 4,80) – – 275 × 790 × 217 53 / 54 365,–

RAS-B13N3KV2-E1 3,50 (1,10 - 4,05) 4,20 (1,00 - 5,30) – – 275 × 790 × 217 54 / 55 395,–

RAS-B16N3KV2-E1 4,50 (0,80 - 5,00) 5,50 (0,90 - 6,90) – – 275 × 790 × 217 60 / 60 435,–

RAS-B22N3KV2-E1 6,00 (1,20 - 6,70) 7,00 (1,00 - 7,50) – – 320 × 1050 × 229 60 / 60 545,–

Super Daiseikai 6.5 (Standard infrared remote control included)

RAS-B10N3KVP-E 2,51 (0,80 - 3,50) 3,21 (0,80 - 5,80) – – 275 × 790 × 225 57 / 58 440,–

RAS-B13N3KVP-E 3,52 (0,90 - 4,10) 4,22 (0,80 - 5,90) – – 275 × 790 × 225 58 / 59 470,–

RAS-B16N3KVP-E 4,53 (0,90 - 5,00) 5,53 (0,80 - 6,70) – – 275 × 790 × 225 60 / 60 515,–

Console (Standard infrared remote control included)

RAS-B10UFV-E(1) 2,50 (1,10 - 3,10) 3,20 (1,00 - 4,80) – – 600 × 700 × 220 54 / 54 850,–

RAS-B13UFV-E(1) 3,50 (1,10 - 4,10) 4,20 (1,00 - 5,40) – – 600 × 700 × 220 55 / 55 930,–

RAS-B18UFV-E1 5,00 (1,00 - 5,70) 5,80 (1,10 - 6,30) – – 600 × 700 × 220 60 / 60 1.120,–

60×60 4-way cassette (Infrared remote control included)

RAS-M10SMUV-E 2,50 (1,10 - 3,20) 3,20 (0,70 - 5,20) – – 268 × 575 × 575 52 / 52 940,–

RAS-M13SMUV-E 3,50 (1,10 - 4,40) 4,20 (0,70 - 6,50) – – 268 × 575 × 575 53 / 53 985,–

RAS-M16SMUV-E 4,50 (1,40 - 4,90) 5,50 (0,80 - 6,90) – – 268 × 575 × 575 55 / 55 1.020,–

RB-B11MC(W)-E, Paneel – – – – 27 × 700 × 700 – 200,–

Duct (Infrared remote control included, drain pump included, cable remote control optional)

RAS-M10G3DV-E 2,70 4,00 – – 210 × 700 × 450 50 / 50 1.150,–

RAS-M13G3DV-E 3,70 5,00 – – 210 × 700 × 450 52 / 52 1.200,–

RAS-M16G3DV-E 4,50 5,50 – – 210 × 900 × 450 50 / 50 1.280,–

❄ Cooling Heating Documented efficiencies in detail on the Web at www.toshiba-aircondition.com

RAS Inverter Multi systems >>Indoor units<<

■ 2-, 3-, 4- and 5-room systems

■ Space-saving installation

■ Reduced installation time

12 I TOSHIBA

P R I C E L I S T – RESIDENTIALR

ESID

ENTI

AL

Accessories Multi

Accessories: Hi-wall

Type Single price excl. VAT (EUR)

43T09485 Panel in silver, compatible with Suzumi Plus size 10-16 55,–

43T09486 Panel in silver, compatible with Suzumi Plus size 18, 22 65,–

43T09487 Panel in silver, compatible with Super Daiseikai 6.5 all sizes 55,–

818F0036 Replacement filter strips for series Suzumi Plus and Super Daiseikai 6.5 30,–

RB-RXS31-E Optional infrared remote control including weekly timer and 8 ° C frost protection function for indoor unit models in E1 75,–

RBC-Combi Control Control of the main functions via SMS or an app (for iOS and Android) as on / off, mode, temperature, fan speed and alarm in case of power failureor too high / too low temperature (Sim card required)

550,–

AP-IR-WIFI-1 WIFI control the air conditioning via smartphones (for iOS and Android), tablet or PC 275,–

TCB-IFCB5-PE P.C. board for external on / off of air conditioner 50,–

Accessories: Console

Type Single price excl. VAT (EUR)

818F0036 Replacement filter strips for console 30,–

RB-RXS30-E Optional infrared remote control including weekly timer and 8 ° C frost protection function for indoor unit models in E1 75,–

RBC-Combi Control Control of the main functions via SMS or an app (for iOS and Android) as on / off, mode, temperature, fan speed and alarm in case of power failureor too high / too low temperature (Sim card required)

550,–

AP-IR-WIFI-1 WIFI control the air conditioning via smartphones (for iOS and Android), tablet or PC 275,–

TCB-IFCB5-PE P.C. board for external on / off of air conditioner 50,–

Accessories: Duct

Type Single price excl. VAT (EUR)

RB-RWS20-E Cable remote control with week timer, especially for RAS multi duct units 300,–

TCB-IFCB5-PE P.C. board for external on / off of air conditioner 50,–

AP-IR-WIFI-1 WIFI control the air conditioning via smartphones (for iOS and Android), tablet or PC 275,–

TCB-DUCEX10M Extension cable for infrared receiver board 10 m 70,–

Accessories: 4-way cassette

Type Single price excl. VAT (EUR)

TCB-IFCB5-PE P.C. board for external on / off of air conditioner 50,–

AP-IR-WIFI-1 WIFI control the air conditioning via smartphones (for iOS and Android), tablet or PC 275,–

Table of combinations RAS Multi outdoor units

RAS-2M14S3AV-E

1 indoor unit 10 13

2 indoor units10 10 13

10 13 13

RAS-2M18S3AV-E

1 indoor unit 10 13 16

2 indoor units10 10 10 13 13 16

10 13 16 13 16 16

RAS-3M18S3AV-E

1 indoor unit 10 13 16

2 indoor units10 10 10 13 13 16

10 13 16 13 16 16

3 indoor units

10 10 10 10

10 10 10 13

10 13 16 13

TOSHIBA I 13

RES

IDEN

TIA

L

RAS Inverter Multi systems >>Outdoor units<<

Table of combinations RAS Multi outdoor units

RAS-3M26S3AV-E

1 indoor unit 10 13 16 18 22

2 indoor units10 10 10 10 10 13 13 13 13 16 16 16 18 18

10 13 16 18 22 13 16 18 22 16 18 22 18 22

3 indoor units

10 10 10 10 10 10 10 10 10 10 10 10 13 13 13 13 13 13 13 16 16 16

10 10 10 10 10 13 13 13 13 16 16 16 13 13 13 13 16 16 16 16 16 16

10 13 16 18 22 13 16 18 22 16 18 22 13 16 18 22 16 18 22 16 18 22

RAS-4M27S3AV-E

1 indoor unit 10 13 16 18 22

2 indoor units10 10 10 10 10 13 13 13 13 16 16 16 18 18

10 13 16 18 22 13 16 18 22 16 18 22 18 22

3 indoor units

10 10 10 10 10 10 10 10 10 10 10 10 10 10 13 13 13 13 13 13 13 13 13 16 16

10 10 10 10 10 13 13 13 13 16 16 16 18 18 13 13 13 13 16 16 16 18 18 16 16

10 13 16 18 22 13 16 18 22 16 18 22 18 22 13 16 18 22 16 18 22 18 22 16 22

4 indoor units

10 10 10 10 10 10 10 10 10 10 10 10 10 13

10 10 10 10 10 10 10 10 10 10 13 13 13 13

10 10 10 10 10 13 13 16 13 16 13 13 13 13

10 13 16 18 22 13 16 16 18 18 13 16 18 13

RAS-5M34S3AV-E

1 indoor unit 10 13 16 18 22

2 indoor units10 10 10 10 10 13 13 13 13 16 16 16 18 18 22

10 13 16 18 22 13 16 18 22 16 18 22 18 22 22

3 indoor units

10 10 10 10 10 10 10 10 10 10 10 10 10 13 13 13 13 13 16 13 13 13 10 13 10

10 10 10 10 10 13 13 13 13 16 16 16 18 13 13 13 13 16 16 16 16 18 18 18 22

10 13 16 18 22 13 16 18 22 16 18 22 18 13 16 18 22 16 16 18 22 18 22 22 22

4 indoor units

10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 13 13 13 13 13 13 13 13 13

10 10 10 10 10 10 10 10 10 10 10 10 10 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13

10 10 10 10 10 13 13 16 16 13 16 16 18 13 13 13 16 16 13 16 18 18 13 13 13 13 16 16 16 18 18

10 13 16 18 22 13 16 22 16 18 22 18 22 13 16 22 16 22 18 18 18 22 13 16 18 22 16 18 22 18 22

5 indoor units

10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 13 13 10 10 10

10 10 10 10 10 10 10 10 10 10 10 10 13 13 13 13 13 13 10 10 10

10 10 10 10 10 10 10 10 13 13 13 13 13 13 13 13 13 13 10 10 13

10 10 10 10 13 13 13 16 13 13 13 16 13 13 13 16 13 13 10 13 13

10 13 16 18 13 16 18 16 13 16 18 16 13 16 18 16 13 16 22 22 22

Table of combinations RAS Multi outdoor units

RAS-2M14S3AV-E

1 indoor unit 10 13

2 indoor units10 10 13

10 13 13

RAS-2M18S3AV-E

1 indoor unit 10 13 16

2 indoor units10 10 10 13 13 16

10 13 16 13 16 16

RAS-3M18S3AV-E

1 indoor unit 10 13 16

2 indoor units10 10 10 13 13 16

10 13 16 13 16 16

3 indoor units

10 10 10 10

10 10 10 13

10 13 16 13

TypeCapacity (kW) Efficiency Dimensions

(H × W × D) (mm)

Power consumption (kW) Sound power level (dB(A)) ❄ /

Single priceexcl. VAT (EUR)

❄ SEER SCOP ❄

Hybrid Inverter Multi outdoor units

RAS-2M14S3AV-E 4,00 (1,60 - 4,90) 4,40 (1,30 - 5,20) 6,73 4,41 630 × 800 × 300 0,83 0,85 42 / 43 1.290,–

RAS-2M18S3AV-E 5,20 (1,70 - 6,20) 5,60 (1,30 - 7,20) 6,90 4,60 630 × 800 × 300 1,34 1,19 45 / 47 1.450,–

RAS-3M18S3AV-E 5,20 (2,40 - 6,50) 6,80 (1,90 - 8,00) 6,80 4,60 630 × 800 × 300 1,17 1,58 45 / 47 1.850,–

RAS-3M26S3AV-E 7,50 (4,10 - 9,00) 9,00 (2,00 - 11,20) 6,19 4,44 890 × 900 × 320 2,00 2,20 63 / 64 2.115,–

RAS-4M27S3AV-E 8,00 (4,20 - 9,30) 9,00 (2,90 - 11,70) 6,11 4,26 890 × 900 × 320 2,29 1,93 63 / 64 2.445,–

RAS-5M34S3AV-E 10,00 (3,70 - 11,00) 12,00 (2,70 - 14,00) 6,31 4,08 890 × 900 × 320 2,98 2,83 66 / 68 2.825,–

❄ Cooling Heating Documented efficiencies in detail on the Web at www.toshiba-aircondition.com

2M14 / 2M18 / 3M18 3M26 / 4M27 / 5M34

14 I TOSHIBA

P R I C E L I S T – RESIDENTIALR

ESID

ENTI

AL

CLASSIC MODEL COMFORT MODEL PREMIUM MODEL PREMIUM MODEL COMFORT MODEL COMFORT MODEL COMFORT MODEL

Model name Mirai Suzumi Plus Super Daiseikai 8 Super Daiseikai 6.5 Console Duct 60 × 60 4-way cassette Model name

Cooling ● ● ● ● ● ● ● Cooling

Heating ● ● ● ● ● ● ● Heating

Hybrid inverter control ● ● ● ● ● ● ● Hybrid inverter control

Rotary compressor ● ● 10/13 ● 10/13 Rotary compressor

Twin-Rotary compressor ● 16/18/22 ● ● ● 18 ● ● Twin-Rotary compressor

Dust filter ● ● ● ● ● ● Dust filter

IAQ filter ● ● ● IAQ filter

Active carbon-catechin filter optional Active carbon-catechin filter

Plasma filter (pure mode) ● ● Plasma filter (pure mode)

Air ionizer ● Air ionizer

SUPER ionizer ● SUPER ionizer

Self-cleaning function ● ● ● ● ● ● ● Self-cleaning function

Automatic mode ● ● ● ● ● ● ● Automatic mode

Hi Power ● ● ● ● ● ● ● Hi Power

Automatic diagnostic ● ● ● ● ● ● ● Automatic diagnostic

Eco mode ● ● ● ● ● ● ● Eco mode

Quiet mode ● ● ● ● Quiet mode

Comfort sleep ● ● ● ● ● Comfort sleep

Power selection * ● ● Series E1* Power selection

WIFI - capable ● ● ● ● ● ● ● WIFI - capable

Weekly timer ● Series E1 Weekly timer

Timer ● ● ● ● ● Timer

Off Timer ● Off Timer

Automatic restart ● ● ● ● ● ● ● Automatic restart

8 °C setting * ● Series E1* 8 °C setting

Floor mode ● Floor mode

Preset mode ● ● ● ● ● ● Preset mode

One Touch mode ● ● ● One Touch mode

Single model ● ● ● ● Single model

Multi model ● ● ● ● ● Multi model

● Standard version Only in combination with optional remote control * Feature only available in the single version

Residential Air ConditionersProduct overview

TOSHIBA I 15

RES

IDEN

TIA

L

CLASSIC MODEL COMFORT MODEL PREMIUM MODEL PREMIUM MODEL COMFORT MODEL COMFORT MODEL COMFORT MODEL

Model name Mirai Suzumi Plus Super Daiseikai 8 Super Daiseikai 6.5 Console Duct 60 × 60 4-way cassette Model name

Cooling ● ● ● ● ● ● ● Cooling

Heating ● ● ● ● ● ● ● Heating

Hybrid inverter control ● ● ● ● ● ● ● Hybrid inverter control

Rotary compressor ● ● 10/13 ● 10/13 Rotary compressor

Twin-Rotary compressor ● 16/18/22 ● ● ● 18 ● ● Twin-Rotary compressor

Dust filter ● ● ● ● ● ● Dust filter

IAQ filter ● ● ● IAQ filter

Active carbon-catechin filter optional Active carbon-catechin filter

Plasma filter (pure mode) ● ● Plasma filter (pure mode)

Air ionizer ● Air ionizer

SUPER ionizer ● SUPER ionizer

Self-cleaning function ● ● ● ● ● ● ● Self-cleaning function

Automatic mode ● ● ● ● ● ● ● Automatic mode

Hi Power ● ● ● ● ● ● ● Hi Power

Automatic diagnostic ● ● ● ● ● ● ● Automatic diagnostic

Eco mode ● ● ● ● ● ● ● Eco mode

Quiet mode ● ● ● ● Quiet mode

Comfort sleep ● ● ● ● ● Comfort sleep

Power selection * ● ● Series E1* Power selection

WIFI - capable ● ● ● ● ● ● ● WIFI - capable

Weekly timer ● Series E1 Weekly timer

Timer ● ● ● ● ● Timer

Off Timer ● Off Timer

Automatic restart ● ● ● ● ● ● ● Automatic restart

8 °C setting * ● Series E1* 8 °C setting

Floor mode ● Floor mode

Preset mode ● ● ● ● ● ● Preset mode

One Touch mode ● ● ● One Touch mode

Single model ● ● ● ● Single model

Multi model ● ● ● ● ● Multi model

● Standard version Only in combination with optional remote control * Feature only available in the single version

16 I TOSHIBA

P R I C E L I S T – LIGHT COMMERCIALLI

GH

T CO

MM

ERCI

AL

TOSHIBA I 17

LIG

HT

COM

MER

CIA

L

Model type HP 2,0 3,0 4,0 5,0 6,0 8,0 10,0

Model type kW 2,5 3,0 3,6 4,0 5,0 5,3 6,0 6,7 6,9 7,1 8,0 10,0 11,2 12,0 12,1 12,5 14,0 16,0 20,0 23,0

HI-WALL

RAV-SM(...)KRT(P)-E

DISDIBIG

CEILING

RAV-SM(…)CTP-EDISDIBIG

CASSETTE

60×60 4-way Cassette

RAV-SM(...)MUT-E

DISDIBIG

4-way Cassette

RAV-SM(...)UTP-E

DISDIBIG

DUCT

Standard Duct

RAV-SM(...)BTP-E

DISDIBIG

Slim Duct

RAV-SM(...)SDT-E

DISDIBIG

High Static Pressure Duct

RAV-SM(...)DT-E

DISDIBIG

AIR CURTAIN

Free-hanging unit

RAV-CT(...)CH-M/L

Cassette

RAV-CT(...)UH-M/L

Built-in unit

RAV-CT(...)BH-M/L

VALVE KIT

RAV-DXC010 / RBC-DXC031

Indoor units

18 I TOSHIBA

P R I C E L I S T – LIGHT COMMERCIALLI

GH

T CO

MM

ERCI

AL

TypeCapacity (kW) Energy label Efficiency Dimensions

(H × W × D) (mm)

Power consumption (kW) Sound power level (dB(A))

❄ /

Single price Set price

❄ ❄ / SEER SCOP ❄ excl. VAT (EUR)

Digital Inverter Hi-wall (Infrared remote control included, cable remote control optional)

RAV-SM307KRTP-E 2,50(0,90 - 3,00)

3,40(0,80 - 4,50)

A+ / A+ 5,90 4,00275 × 790× 217

0,61 0,8555 / 44 450,–

1.310,–RAV-SM304ATP-E 550 × 780 × 290 61 / 62 860,–

RAV-SM407KRTP-E 3,60(0,90 - 4,00)

4,00(0,80 - 5,00)

A / A+ 5,40 4,12275 × 790 × 217

1,13 1,1256 / 45 480,–

1.530,–RAV-SM404ATP-E 550 × 780 × 290 64 / 65 1.050,–

RAV-SM566KRT-E 5,00(1,50 - 5,60)

5,30(1,50 - 6,30)

A+ / A+ 5,77 4,00320 × 1050 × 228

0,30 - 1,86 0,31 - 2,8557 / 51 530,–

1.730,–RAV-SM564ATP-E 550 × 780 × 290 63 / 65 1.200,–

RAV-SM806KRT-E 6,70(1,50 - 7,00)

7,70(1,50 - 9,00)

A+ / A+ 5,62 4,01320 × 1050 × 228

0,31 - 2,85 0,31 - 3,3062 / 51 550,–

2.090,–RAV-SM804ATP-E 550 × 780 × 290 65 / 69 1.540,–

Super Digital Inverter Hi-wall (Infrared remote control included, TCC-Link remote control optional)

RAV-SM566KRT-E 5,00(1,20 - 5,60)

5,60(0,90 - 7,30)

A+ / A+ 5,82 4,01320 × 1050 × 228

0,21 - 2,05 0,17 - 2,5757 / 51 530,–

1.980,–RAV-SP564ATP-E 550 × 780 × 290 63 / 64 1.450,–

RAV-SM806KRT-E 7,10(1,90 - 8,00)

8,00(1,30 - 10,60)

A+ / A 5,88 3,87320 × 1050 × 228

0,30 - 2,88 0,27 - 3,8762 / 61 550,–

2.490,–RAV-SP804ATP-E 890 × 900 × 320 64 / 65 1.940,–

Accessories

Type Single price excl. VAT (EUR)

818F0036 Optional filter strips 30,–

Digital Inverter & Super Digital InverterHi-wall

■ NEW: Smaller sizes available

■ Precise temperature control in cooling and heating

■ Filter system for clean air

■ Low noise level, 3-stage fan

■ Large air conducting strip for optimum air distribution

■ Auto restart after power failure programmable

RAV-SM307KRTP-ERAV-SM407KRTP-E

RAV-SM566KRT-ERAV-SM806KRT-E

TOSHIBA I 19

LIG

HT

COM

MER

CIA

L

Digital Inverter & Super Digital Inverter60 × 60 4-way Cassette

■ Compact indoor unit: suitable for all euro-grid ceilings

■ Low unit height of only 268 mm

■ Four air louvers for optimal air distribution

■ Fresh air intake possible with external fan to 15% of the nominal amount of air in the indoor unit

■ Drain pump with 850 mm lifting height installed (measured from the bottom edge of the unit)

■ Auto restart after power failure programmable

TypeCapacity (kW) Energy label Efficiency Dimensions

(H × W × D) (mm)

Power consumption (kW) Sound power level (dB(A))

❄ /

Single price Set price

❄ ❄ / SEER SCOP ❄ excl. VAT (EUR)

Digital Inverter 60 × 60 euro-grid 4-way cassette

RAV-SM304MUT-E

2,50(0,90 - 3,00)

3,40(0,80 - 4,50)

A / A+ 5,53 4,27

268 × 575 × 575

0,59 0,76

55 / 46 880,–

2.145,–RBC-UM11PG(W)-E 27 × 700 × 700 – 310,–

RAV-SM304ATP-E 550 × 780 × 290 61 / 62 860,–

RBC-AMT32E – – 95,–

RAV-SM404MUT-E

3,60(0,90 - 4,00)

4,00(0,80 - 5,00)

A / A+ 5,35 4,27

268 × 575 × 575

0,90 0,95

55 / 46 900,–

2.355,–RBC-UM11PG(W)-E 27 × 700 × 700 – 310,–

RAV-SM404ATP-E 550 × 780 × 290 64 / 65 1.050,–

RBC-AMT32E – – 95,–

RAV-SM564MUT-E

5,00(1,50 - 5,60)

5,30(1,50 - 6,30)

A / A+ 5,48 4,16

268 × 575 × 575

0,30 - 1,86 0,30 - 2,40

58 / 49 910,–

2.515,–RBC-UM11PG(W)-E 27 × 700 × 700 – 310,–

RAV-SM564ATP-E 550 × 780 × 290 63 / 65 1.200,–

RBC-AMT32E – – 95,–

Super Digital Inverter 60 × 60 euro-grid 4-way cassette

RAV-SM564MUT-E

5,00(1,20 - 5,60)

5,60(0,90 - 7,40)

A+ / A+ 5,61 4,20

268 × 575 × 575

0,21 - 2,29 0,17 - 2,37

58 / 58 910,–

2.765,–RBC-UM11PG(W)-E 27 × 700 × 700 – 310,–

RAV-SP564ATP-E 550 × 780 × 290 63 / 64 1.450,–

RBC-AMT32E – – 95,–

❄Cooling Heating

20 I TOSHIBA

P R I C E L I S T – LIGHT COMMERCIALLI

GH

T CO

MM

ERCI

AL

Digital Inverter4-way Cassette

■ Beautiful design with two ceiling panels to choose from (wider or direct airflow)

■ Deodorising Ag+ ion capsule

■ Fresh air intake possible with external fan to 15% of the nominal amount of air in the indoor unit

■ Drain pump with 850 mm lifting height installed (measured from the bottom edge of the unit)

■ Auto restart after power failure programmable

■ Night Operation: particularly quiet operation of the outdoor unit in conjunction with RBC AMS51E-ES

TypeCapacity (kW) Energy label Efficiency Dimensions

(H × W × D) (mm)

Power consumption (kW) Sound power level (dB(A))

❄ /

Single price Set price

❄ ❄ / SEER SCOP ❄ excl. VAT (EUR)

Digital Inverter Cassette

RAV-SM564UTP-E

5,00(1,50 - 5,60)

5,30(1,50 - 6,30)

A++ / A+ 6,14 4,51

256 × 840 × 840

0,26 - 1,86 0,26 - 2,08

47 / 43 840,–

2.415,–RBC-U31PGP(W)-E 30 × 950 × 950 – 280,–

RAV-SM564ATP-E 550 × 780 × 290 63 / 65 1.200,–

RBC-AMT32E – – 95,–

RAV-SM804UTP-E

6,70(1,50 - 8,00)

7,70(1,50 - 9,00)

A+ / A+ 5,81 4,05

256 × 840 × 840

0,26 - 2,60 0,26 - 3,03

50 /43 960,–

2.875,–RBC-U31PGP(W)-E 30 × 950 × 950 – 280,–

RAV-SM804ATP-E 550 × 780 × 290 65 / 69 1.540,–

RBC-AMT32E – 95,–

RAV-SM1104UTP-E

10,00(3,00 - 11,20)

11,20(3,00 - 13,00)

A+ / A+ 5,87 4,28

319 × 840 × 840

0,60 - 4,10 0,60 - 4,30

58 / 48 1.180,–

3.575,–RBC-U31PGP(W)-E 30 × 950 × 950 – 280,–

RAV-SM1104ATP-E 890 × 900 × 320 70 / 71 2.020,–

RBC-AMT32E – – 95,–

RAV-SM1404UTP-E

12,00(3,00 - 13,20)

12,80(3,00 - 16,00)

A / A+ 5,36 4,19

319 × 840 × 840

0,60 - 4,71 0,60 - 4,50

59 / 49 1.320,–

3.865,–RBC-U31PGP(W)-E 30 × 950 × 950 – 280,–

RAV-SM1404ATP-E 890 × 900 × 320 70 / 71 2.170,–

RBC-AMT32E – – 95,–

RAV-SM1604UTP-E

14,00(3,00 - 16,00)

16,00(3,00 - 18,00)

B / B – –

319 × 840 × 840

0,65 - 5,70 0,65 - 6,51

60 / 51 1.490,–

4.715,–RBC-U31PGP(W)-E 30 × 950 × 950 – 280,–

RAV-SM1603AT-E 1340 × 900 × 320 68 / 70 2.850,–

RBC-AMT32E – – 95,–

❄ Cooling Heating

RBC-U31PGP(W)-E Panel for wide airflow 280,–

RBC-U31PGSP(W)-E Panel for direct airflow 300,–

Panel RBC-U31PGP(W)-E The special fin shapeensures a perfect airdistribution within aradius of 360°.This is a TOSHIBAexclusive preference!

Panel RBC-U31PGSP(W)-E The design of the louversensures that the air currentsare blown out in a straightline.

TOSHIBA I 21

LIG

HT

COM

MER

CIA

L

TypeCapacity (kW) Energy label Efficiency Dimensions

(H × W × D) (mm)

Power consumption (kW) Sound power level (dB(A))

❄ /

Single price Set price

❄ ❄ / SEER SCOP ❄ excl. VAT (EUR)

Super Digital Inverter Cassette

RAV-SM564UTP-E

5,30(1,20 - 5,60)

5,60(0,90 - 8,10)

A++ / A+ 6,17 4,58

256 × 840 × 840

0,20 - 1,95 0,15 - 2,40

47 / 47 840,–

2.665,–RBC-U31PGP(W)-E 30 × 950 × 950 – 280,–

RAV-SP564ATP-E 550 × 780 × 290 63 / 64 1.450,–

RBC-AMT32E - – 95,–

RAV-SM804UTP-E

7,10(1,90 - 8,00)

8,00(1,30 - 11,30)

A++ / A+ 6,39 4,19

256 × 840 × 840

0,30 - 2,52 0,25 - 3,52

50 / 50 960,–

3.275,–RBC-U31PGP(W)-E 30 × 950 × 950 – 280,–

RAV-SP804ATP-E 890 × 900 × 320 64 / 65 1.940,–

RBC-AMT32E - – 95,–

RAV-SM1104UTP-E

10,00(2,60 - 12,00)

11,20(2,40 - 13,00)

A++ / A+ 6,60 4,28

319 × 840 × 840

0,64 - 3,60 0,52 - 4,20

58 / 58 1.180,–

4.185,–RBC-U31PGP(W)-E 30 × 950 × 950 – 280,–

RAV-SP1104AT-E 1340 × 900 × 320 66 / 67 2.630,–

RBC-AMT32E - – 95,–

RAV-SM1104UTP-E

10,00(2,60 - 12,00)

11,20(2,40 - 15,60)

A++ / A+ 6,57 4,28

319 × 840 × 840

0,66 - 3,60 0,53 - 4,30

58 / 58 1.180,–

4.605,–RBC-U31PGP(W)-E 30 × 950 × 950 – 280,–

RAV-SP1104AT8-E * 1340 × 900 × 320 66 / 67 3.050,–

RBC-AMT32E - – 95,–

RAV-SM1404UTP-E

12,50(2,60 - 14,00)

14,00(2,40 - 16,50)

A / A – –

319 × 840 × 840

0,64 - 4,40 0,52 - 4,50

59 / 59 1.320,–

4.635,–RBC-U31PGP(W)-E 30 × 950 × 950 – 280,–

RAV-SP1404AT-E 1340 × 900 × 320 68 / 69 2.940,–

RBC-AMT32E - – 95,–

RAV-SM1404UTP-E

12,50(2,60 - 14,00)

14,00(2,40 - 18,00)

A / A – –

319 × 840 × 840

0,66 - 4,40 0,53 - 5,50

59 / 59 1.320,–

4.875,–RBC-U31PGP(W)-E 30 × 950 × 950 – 280,–

RAV-SP1404AT8-E * 1340 × 900 × 320 68 / 69 3.180,–

RBC-AMT32E - – 95,–

RAV-SM1604UTP-E

14,00(2,60 - 16,00)

16,00(2,40 - 19,00)

B / A – –

319 × 840 × 840

0,66 - 5,70 0,53 - 6,51

60 / 60 1.490,–

5.515,–RBC-U31PGP(W)-E 30 × 950 × 950 – 280,–

RAV-SP1604AT8-E * 1340 × 900 × 320 68 / 70 3.650,–

RBC-AMT32E - – 95,–

❄ Cooling Heating * 3-phase outdoor unit

RBC-U31PGP(W)-E Panel for wide airflow 280,–

RBC-U31PGSP(W)-E Panel for direct airflow 300,–

Super Digital Inverter 4-way Cassette

■ Excellent efficiency

■ Beautiful design with two ceiling panels to choose from (wider or direct airflow)

■ Deodorising Ag+ ion capsule

■ Fresh air intake possible with external fan to 15% of the nominal amount of air in the indoor unit

■ Drain pump with 850 mm lifting height installed (measured from the bottom edge of the unit)

■ Auto restart after power failure programmable

■ Night Operation: particularly quiet operation of the outdoor unit in conjunction with RBC AMS51E-ES

22 I TOSHIBA

P R I C E L I S T – LIGHT COMMERCIALLI

GH

T CO

MM

ERCI

AL Type

Capacity (kW) Energy label Efficiency Dimensions(H × W × D) (mm)

Power consumption (kW) Sound power level (dB(A))

❄ /

Single price Set price

❄ ❄ / SEER SCOP ❄ excl. VAT (EUR)

Digital Inverter Ceiling

RAV-SM407CTP-E3,60

(0,90 - 4,00)

4,00(0,80 - 5,00)

A+ / A++ 5,96 4,98

235 × 950 × 690

0,38 0,78

52 / 43 880,–

2.025,–RAV-SM404ATP-E 550 × 780 × 290 64 / 65 1.050,–

RBC-AMT32E – – 95,–

RAV-SM567CTP-E5,00

(1,50 - 5,60)

5,30(1,50 - 6,30)

A / A+ 5,41 4,21

235 × 950 × 690

0,29 - 1,95 0,29 - 2,40

52 / 43 930,–

2.225,–RAV-SM564ATP-E 550 × 780 × 290 63 / 65 1.200,–

RBC-AMT32E – – 95,–

RAV-SM807CTP-E6,90

(1,50 - 7,40)

7,70(1,50 - 9,00)

A+ / A+ 5,62 4,01

235 × 1270 × 690

0,29 - 2,76 0,29 - 3,20

56 / 44 1.050,–

2.685,–RAV-SM804ATP-E 550 × 780 × 290 65 / 69 1.540,–

RBC-AMT32E – – 95,–

RAV-SM1107CTP-E10,00

(3,00 - 11,20)

11,20(3,00 - 12,50)

A+ / A+ 5,79 4,27

235 × 1586 × 690

0,60 - 4,10 0,60 - 4,10

59 / 47 1.170,–

3.285,–RAV-SM1104ATP-E 890 × 900 × 320 70 / 71 2.020,–

RBC-AMT32E – – 95,–

RAV-SM1407CTP-E12,10

(3,00 - 13,20)

12,80(3,00 - 16,00)

D / A – –

235 × 1586 × 690

0,60 - 4,71 0,65 - 4,60

61 / 50 1.320,–

3.585,–RAV-SM1404ATP-E 890 × 900 × 320 70 / 71 2.170,–

RBC-AMT32E – – 95,–

RAV-SM1607CTP-E14,00

(3,00 - 16,00)

16,00(3,00 - 18,00)

B / A – –

235 × 1586 × 690

0,65 - 6,33 0,65 - 6,89

61 / 51 1.400,–

4.345,–RAV-SM1603AT-E 1340 × 900 × 320 68 / 70 2.850,–

RBC-AMT32E – – 95,–

Super Digital Inverter Ceiling

RAV-SM567CTP-E5,00

(1,20 - 5,60)

5,60(0,90 - 7,40)

A / A+ 5,45 4,28

235 × 950 × 690

0,21 - 2,26 0,17 - 2,34

52 / 52 930,–

2.475,–RAV-SP564ATP-E 550 × 780 × 290 63 / 64 1.450,–

RBC-AMT32E – – 95,–

RAV-SM807CTP-E7,10

(1,90 - 8,00)

8,00(1,30 - 10,60)

A++/ A+ 6,21 4,10

235 × 1270 × 690

0,30 - 2,88 0,27 - 3,50

56 / 56 1.050,–

3.085,–RAV-SP804ATP-E 890 × 900 × 320 64 / 65 1.940,–

RBC-AMT32E – – 95,–

RAV-SM1107CTP-E10,00

(2,60 - 12,00)

11,20(2,40 - 13,00)

A++/ A+ 6,18 4,27

235 × 1586 × 690

0,64 - 3,70 0,52 - 4,00

59 / 59 1.170,–

3.895,–RAV-SP1104AT-E 1340 × 900 × 320 66 / 67 2.630,–

RBC-AMT32E – – 95,–

RAV-SM1107CTP-E10,00

(2,60 - 12,00)

11,20(2,40 - 16,50)

A++/ A+ 6,35 4,41

235 × 1586 × 690

0,66 - 3,81 0,53 - 4,26

59 / 59 1.170,–

4.315,–RAV-SP1104AT8-E * 1340 × 900 × 320 66 / 67 3.050,–

RBC-AMT32E – – 95,–

RAV-SM1407CTP-E12,50

(2,60 - 14,00)

14,00(2,40 - 16,50)

B / A – –

235 × 1586 × 690

0,64 - 4,47 0,52 - 4,60

61 / 61 1.320,–

4.355,–RAV-SP1404AT-E 1340 × 900 × 320 68 / 69 2.940,–

RBC-AMT32E – – 95,–

RAV-SM1407CTP-E12,50

(2,60 - 14,00)

14,00(2,40 - 18,00)

A / A – –

235 × 1586 × 690

0,66 - 4,85 0,53 - 5,95

61 / 61 1.320,–

4.595,–RAV-SP1404AT8-E * 1340 × 900 × 320 68 / 69 3.180,–

RBC-AMT32E – – 95,–

RAV-SM1607CTP-E14,00

(2,60 - 16,00)

16,00(2,40 - 19,00)

A / A – –

235 × 1586 × 690

0,66 - 6,33 0,53 - 6,96

61 / 61 1.400,–

5.145,–RAV-SP1604AT8-E * 1340 × 900 × 320 68 / 70 3.650,–

RBC-AMT32E – – 95,–

❄ Cooling Heating * 3-phase outdoor unit

Accessories RAV Ceiling models

Type Description CompatiblePrices

excl. VAT (EUR)

TCB-DP31CE Drain pump 290,–

TCB-KP13CE Elbow piping kit (is required for drain pump) Size 567 80,–

TCB-KP23CE Elbow piping kit (is required for drain pump) Size 807-1607 95,–

TCB-PCUC1E Optional control kit Functions: Analog inputs and digital inputs / outputs for external control, alarms andmessages

130,–

Digital Inverter & Super Digital InverterCeiling

■ Attractive design with improved energy efficiency

■ Low noise level

■ Large air conducting strip for optimum air distribution

TOSHIBA I 23

LIG

HT

COM

MER

CIA

L

TypeCapacity (kW) Energy label Efficiency Dimensions

(H × W × D) (mm)

Power consumption (kW) Sound power level (dB(A))

❄ /

Single price Set price

❄ ❄ / SEER SCOP ❄ excl. VAT (EUR)

Digital Inverter Duct

RAV–SM566BTP–E5,00

(1,50 - 5,60)

5,30(1,50 - 6,30)

B / A 4,80 3,98

275 × 700 × 750

0,31 - 2,05 0,31 - 2,47

48 / 40 940,–

2.235,–RAV-SM564ATP-E 550 × 780 × 290 63 / 65 1.200,–

RBC-AMT32E – – 95,–

RAV-SM806BTP-E6,70

(1,50 - 7,40)

7,70(1,50 - 9,00)

B / A 5,04 3,83

275 × 1000 × 750

0,31 - 2,76 0,31 - 3,18

49 / 41 1.070,–

2.705,–RAV-SM804ATP-E 550 × 780 × 290 65 / 69 1.540,–

RBC-AMT32E – – 95,–

RAV-SM1106BTP-E10,00

(3,00 - 11,20)

11,20(3,00 - 12,50)

B / A+ 5,03 4,14

275 × 1400 × 750

0,60 - 4,50 0,60 - 4,00

55 / 48 1.320,–

3.435,–RAV-SM1104ATP-E 890 × 900 × 320 70 / 71 2.020,–

RBC-AMT32E – – 95,–

RAV-SM1406BTP-E12,10

(3,00 - 13,20)

12,80(3,00 - 16,00)

D / B – –

275 × 1400 × 750

0,60 - 4,71 0,60 - 4,55

55 / 48 1.370,–

3.635,–RAV-SM1404ATP-E 890 × 900 × 320 70 / 71 2.170,–

RBC-AMT32E - – 95,–

RAV-SM1606BTP-E14,00

(3,00 - 16,00)

16,00(3,00 - 18,00)

D / C – –

275 × 1400 × 750

0,65 - 6,50 0,65 - 6,89

55 / 48 1.480,–

4.425,–RAV-SM1603AT-E 1340 × 900 × 320 68 / 70 2.850,–

RBC-AMT32E – – 95,–

Super Digital Inverter Duct

RAV-SM566BTP-E5,00

(1,20 - 5,60)

5,60(0,90 - 7,40)

B / A+ 4,88 4,01

275 × 700 × 750

0,21 - 2,05 0,17 - 2,51

48 / 40 940,–

2.485,–RAV-SP564ATP-E 550 × 780 × 290 63 / 64 1.450,–

RBC-AMT32E – – 95,–

RAV-SM806BTP-E7,10

(1,90 - 8,00)

8,00(1,30 - 10,60)

A+ / A+ 5,88 4,00

275 × 1000 × 750

0,30 - 2,88 0,27 - 3,50

49 / 41 1.070,–

3.105,–RAV-SP804ATP-E 890 × 900 × 320 64 / 65 1.940,–

RBC-AMT32E – – 95,–

RAV-SM1106BTP-E10,00

(2,60 - 12,00)

11,20(2,40 - 13,00)

A+ / A 5,65 3,87

275 × 1400 × 750

0,64 - 3,80 0,52 - 4,00

55 / 48 1.320,–

4.045,–RAV-SP1104AT-E 1340 × 900 × 320 66 / 67 2.630,–

RBC-AMT32E – – 95,–

RAV-SM1106BTP-E10,00

(2,60 - 12,00)

11,20(2,40 - 15,60)

A+ / A 5,65 3,87

275 × 1400 × 750

0,66 - 4,01 0,53 - 4,42

55 / 48 1.320,–

4.465,–RAV-SP1104AT8-E * 1340 × 900 × 320 66 / 67 3.050,–

RBC-AMT32E – – 95,–

RAV-SM1406BTP-E12,50

(2,60 - 14,00)

14,00(2,40 - 16,50)

B / A – –

275 × 1400 × 750

0,64 - 4,47 0,52 - 4,50

55 / 48 1.370,–

4.405,–RAV-SP1404AT-E 1340 × 900 × 320 68 / 69 2.940,–

RBC-AMT32E – – 95,–

RAV-SM1406BTP-E12,50

(2,60 - 14,00)

14,00(2,40 - 18,00)

B / A – –

275 × 1400 × 750

0,66 - 4,89 0,53 - 5,71

55 / 48 1.370,–

4.645,–RAV-SP1404AT8-E * 1340 × 900 × 320 68 / 69 3.180,–

RBC-AMT32E – – 95,–

RAV-SM1606BTP-E14,00

(2,60 - 16,00)

16,00(2,40 - 19,00)

C / A – –

275 × 1400 × 750

0,66 - 6,50 0,53 - 6,96

55 / 48 1.480,–

5.225,–RAV-SP1604AT8-E * 1340 × 900 × 320 68 / 70 3.650,–

RBC-AMT32E – – 95,–

❄ Cooling Heating * 3-phase outdoor unit

Digital Inverter & Super Digital InverterDuct

■ Compact dimensions for installation in suspended ceilings

■ Height of only 275 mm

■ External static pressure up to 120 Pa

■ Drain pump with 850 mm lifting height included (measured from the bottom edge of the unit)

Accessories Duct units

Type Single price excl. VAT (EUR)

TCB-SF56C6BPE Flange for RAV-SM566BTP-E (2 × Ø 200 mm) 120,–

TCB-SF80C6BPE Flange for RAV-SM806BTP-E (3 × Ø 200 mm) 145,–

TCB-SF160C6BPE Flange for RAV-SM1106/1406/1606BTP-E (4 × Ø 200 mm) 180,–

24 I TOSHIBA

P R I C E L I S T – LIGHT COMMERCIALLI

GH

T CO

MM

ERCI

AL

TypeCapacity (kW) Energy label Efficiency Dimensions

(H × W × D) (mm)

Power consumption (kW) Sound power level (dB(A))

❄ /

Single price Set price

❄ ❄ / SEER SCOP ❄ excl. VAT (EUR)

High-pressure Duct – combination only with Digital Inverter BIG

RAV-SM2242DT-E1)

20,00(9,80 - 22,40)

22,40(9,80 - 25,00)

D / B – –

470 × 1380 × 1250

3,26 - 9,09 2,57 - 7,45

74 / 74 4.190,–

8.675,–RAV-SM2244AT8-E * 1540 × 900 × 320 72 / 74 4.390,–

RBC-AMT32E - – 95,–

RAV-SM2802DT-E1)

23,00(9,80 - 27,00)

27,00(9,80 - 31,50)

D / C – –

470 × 1380 × 1250

3,36 - 12,76 2,57 - 11,01

75 / 75 4.500,–

9.405,–RAV-SM2804AT8-E * 1540 × 900 × 320 74 / 75 4.810,–

RBC-AMT32E - – 95,–

1) Model change on Series 4 during the summer 2016

TypeCapacity (kW) Energy label Efficiency Dimensions

(H × W × D) (mm)

Power consumption (kW) Sound power level (dB(A))

❄ /

Single price Set price

❄ ❄ / SEER SCOP ❄ excl. VAT (EUR)

Digital Inverter Slim Duct

RAV-SM304SDT-E2,50

(0,90 - 3,00)

3,40(0,80)

A++ / A+ 6,10 4,48

210 × 845 × 645

0,56 0,86

54 / 48 1.000,–

1.955,–RAV-SM304ATP-E 550 × 780 × 290 61 / 62 860,–

RBC-AMT32E – – 95,–

RAV-SM404SDT-E3,60

(0,90 - 4,00)

4,00(4,50)

A / A 5,55 3,88

210 × 845 × 645

0,93 0,97

54 / 48 1.030,–

2.175,–RAV-SM404ATP-E 550 × 780 × 290 64 / 65 1.050,–

RBC-AMT32E – – 95,–

RAV-SM564SDT-E5,00

(1,50 - 5,60)

5,30(1,50 - 6,30)

B / A+ 5,06 4,06

210 × 845 × 645

0,32 - 2,75 0,32 - 2,40

60 / 51 1.050,–

2.345,–RAV-SM564ATP-E 550 × 780 × 290 63 / 65 1.200,–

RBC-AMT32E – – 95,–

Super Digital Inverter Slim Duct

RAV-SM564SDT-E5,00

(1,20 - 5,60)

5,60(0,90 - 7,40)

A / A 5,10 3,83

210 × 845 × 645

0,21 - 2,29 0,17 - 2,37

60 / 60 1.050,–

2.595,–RAV-SP564ATP-E 550 × 780 × 290 63 / 64 1.450,–

RBC-AMT32E – – 95,–

Digital Inverter & Super Digital InverterSlim Duct

Digital Inverter BIGHigh-pressure Duct

■ Low unit height of only 210 mm

■ Suitable for installation in suspended ceilings

■ Energy-saving mode possible

■ Drain pump with 850 mm lifting height installed (measured from the bottom edge of the unit)

■ High-pressure model for single-application

■ Combination with Digital Inverter BIG

■ External static pressure up to 196 Pa

❄ Cooling Heating * 3-phase outdoor unit

TOSHIBA I 25

LIG

HT

COM

MER

CIA

L

TypeCapacity (kW) Dimensions

(H × W × D) (mm)

Power consumption (kW) Sound power level (dB(A))

Single priceexcl. VAT (EUR)

❄ ❄

Digital Inverter outdoor unit 1-phase

RAV-SM1104ATP-E 10,00 11,20 890 × 900 × 320

depending on

combination with

indoor unit

70 / 71 2.020,–

RAV-SM1404ATP-E 12,10 12,80 890 × 900 × 320 70 / 71 2.170,–

RAV-SM1603AT-E 14,00 16,00 1340 × 900 × 320 68 / 70 2.850,–

Super Digital Inverter outdoor unit 1-phase

RAV-SP1104AT-E 10,00 11,20 1340 × 900 × 320 66 / 67 2.630,–

RAV-SP1404AT-E 12,50 14,00 1340 × 900 × 320 68 / 69 2.940,–

Super Digital Inverter outdoor unit 3-phase

RAV-SP1104AT8-E 10,00 11,20 1340 × 900 × 320 66 / 67 3.050,–

RAV-SP1404AT8-E 12,50 14,00 1340 × 900 × 320 68 / 69 3.180,–

RAV-SP1604AT8-E 14,00 16,00 1340 × 900 × 320 68 / 70 3.650,–

DI – Big outdoor unit

RAV-SM2244AT8-E 20,00 22,40 1540 × 900 × 320 3,26 - 9,09 2,57 - 7,45 72 / 74 4.390,–

RAV-SM2804AT8-E 23,00 27,00 1540 × 900 × 320 3,36 - 12,76 2,57 - 11,01 74 / 75 4.810,–

Table of combinations – Digital Inverter BIG

System (kW) Indoor unit (kW) **

❄ Twin Triple Double-Twin

20,00 kW 22,40 kW 11,20 + 11,20 kW 8,00 + 8,00 + 8,00 kW 5,60 + 5,60 + 5,60 + 5,60 kW

23,00 kW 27,00 kW 14,00 + 14,00 kW 8,00 + 8,00 + 8,00 kW 8,0 0+ 8,00 + 8,00 + 8,00 kW

Table of combinations – Digital Inverter, Super Digital Inverter

System Indoor unit (kW) **

❄ Twin Triple

10,00 kW 11,20 kW 5,60 + 5,60 kW –

12,50 kW 14,00 kW 8,00 + 8,00 kW –

14,00 kW 16,00 kW 8,00 + 8,00 kW 5,60 + 5,60 + 5,60 kW

❄ Cooling Heating ** Indoor unit types have to be identical

RAV SPLIT SOLUTIONS for one temperature zone

■ Affordable multi-solutions for one temperature zone

■ Twin, Triple and Double Twin Split combinations in conjunction with a wired remote control possible

■ Indoor unit have to be identical for multi-solutions (same construction and capacity)

Valve kit for Digital Inverter, Super Digital Inverter,Digital Inverter Big

■ DX Kit with PC board, transformer, terminal strips and installation instructions

■ Remote control must be ordered separately

■ Applicable in conjunction with ventilation systems and air-curtains

■ Available in two different versions for exhaust air temperature control or 0-10V control

Type Single price excl. VAT (EUR)

Exhaust temperature control

RAV-DXC010 Cooling and heating operation, for all Super Digital and Digital Inverter as well as DI BIG 1.050,–

Power control

RBC-DXC031 Control unit for power control via 0-10V signal 1.150,–

26 I TOSHIBA

P R I C E L I S T – LIGHT COMMERCIALLI

GH

T CO

MM

ERCI

AL

TypeSingle price

excl. VAT (EUR)

Digital Inverter BIG

RBC-TWP101E Twin Kit 22,40 and 27,00 kW 195,–

RBC-TRP100E Triple Kit 22,40 and 27,00 kW 270,–

RBC-DTWP101E Double Twin Kit 22,40 and 27,00 kW 280,–

Digital Inverter / Super Digital Inverter

RBC-TWP30E2 Twin Kit 11,20 kW 90,–

RBC-TWP50E2 Twin Kit 14,00 kW 95.–

RBC-TRP100E Triple Kit 16,00 kW 270,–

Joints for Multi installations

TOSHIBA I 27

LIG

HT

COM

MER

CIA

L

DIGITAL INVERTERAir Curtain

■ Three standard versions, each in two versions with different pressure

■ Customized solutions on request

■ Compatible with Digital Inverter and Super Digital Inverter

■ Rapid installation

■ Uncomplicated access for maintenance

TypeCapacity (kW) Dimensions

(H × W × D) (mm)Air flow(m3/h)

Room heightin m

Sound pressure(dB(A))

Single price

Code (HP) Heating capacity (kW) excl. VAT (EUR)

Free-hanging unit

RAV-CT101CH-M 3 8,00 260 × 1210 × 490 1600 3,00 54 7.315,–

RAV-CT101CH-L 3 8,00 260 × 1210 × 490 2210 3,20 55 7.500,–

RAV-CT151CH-M 4 11,20 260 × 1710 × 490 2400 3,00 55 8.565,–

RAV-CT151CH-L 4 11,20 260 × 1710 × 490 2950 3,20 56 8.740,–

RAV-CT201CH-M 5 14,00 260 × 2210 × 490 3200 3,00 56 9.625,–

RAV-CT201CH-L 5 14,00 260 × 2210 × 490 4420 3,20 57 10.500,–

RAV-CT251CH-M 6 16,00 260 × 2710 × 490 4000 3,00 57 10.875,–

RAV-CT251CH-L 6 16,00 260 × 2710 × 490 5160 3,20 58 11.440,–

Cassette

RAV-CT101UH-M 3 8,00 260 × 1050 × 755 1600 3,00 54 7.690,–

RAV-CT101UH-L 3 8,00 260 × 1050 × 755 2210 3,20 55 8.025,–

RAV-CT151UH-M 4 11,20 260 × 1550 × 755 2400 3,00 55 8.625,–

RAV-CT151UH-L 4 11,20 260 × 1550 × 755 2950 3,20 56 9.000,–

RAV-CT201UH-M 5 14,00 260 × 2050 × 755 3200 3,00 56 9.750,–

RAV-CT201UH-L 5 14,00 260 × 2050 × 755 4420 3,20 57 10.565,–

RAV-CT251UH-M 6 16,00 260 × 2550 × 755 4000 3,00 57 11.600,–

RAV-CT251UH-L 6 16,00 260 × 2550 × 755 5160 3,20 58 12.375,–

Built-in unit

RAV-CT101BH-M 3 8,00 405 - 485 × 1105 × 720 1600 3,00 54 8.065,–

RAV-CT101BH-L 3 8,00 405 - 485 × 1105 × 720 2210 3,20 55 8.315,–

RAV-CT151BH-M 4 11,20 405 - 485 × 1605 × 720 2400 3,00 55 9.565,–

RAV-CT151BH-L 4 11,20 405 - 485 × 1605 × 720 2950 3,20 56 9.750,–

RAV-CT201BH-M 5 14,00 405 - 485 × 2105 × 720 3200 3,00 56 10.815,–

RAV-CT201BH-L 5 14,00 405 - 485 × 2105 × 720 4420 3,20 57 11.625,–

RAV-CT251BH-M 6 16,00 405 - 485 × 2605 × 720 4000 3,00 57 12.165,–

RAV-CT251BH-L 6 16,00 405 - 485 × 2605 × 720 5160 3,20 58 12.625,–

28 I TOSHIBA

P R I C E L I S T – LIGHT COMMERCIALLI

GH

T CO

MM

ERCI

AL

Compatible outdoor units to the air curtains

TypeCapacity (kW) Dimensions

(H × W × D) (mm)

Power consumption (kW) Sound power level (dB(A)) Single priceexcl. VAT (EUR)

RAV-SM804ATP-E 7,70 550 × 780 × 290 0,31 - 3,18 69 1.540,–

RAV-SM1104ATP-E 11,20 890 × 900 × 320 0,60 - 4,00 71 2.020,–

RAV-SM1404ATP-E 12,80 890 × 900 × 320 0,60 - 4,55 71 2.170,–

RAV-SM1603AT-E 16,00 1340 × 900 × 320 0,65 - 6,89 70 2.850,–

RAV-SP804ATP-E 8,00 890 × 900 × 320 0,27 - 3,50 65 1.940,–

RAV-SP1104AT-E 11,20 1340 × 900 × 320 0,52 - 4,00 67 2.630,–

RAV-SP1104AT8-E* 11,20 1340 × 900 × 320 0,53 - 4,42 67 3.050,–

RAV-SP1404AT-E 14,00 1340 × 900 × 320 0,52 - 4,50 69 2.940,–

RAV-SP1404AT8-E* 14,00 1340 × 900 × 320 0,53 - 5,71 69 3.180,–

RAV-SP1604AT8-E* 16,00 1340 × 900 × 320 0,53 - 6,96 70 3.650,–

Heating

* 3-phase outdoor unit

Example of calculation: Built-in model with 8 kW in combination with a Digital Inverter outdoor unit

TypeCapacity (kW) Dimensions

(H × W × D) (mm)Air flow(m3/h)

Sound pressure(dB(A))

Single price Set price

Code (HP) Heating capacity (kW) excl. VAT (EUR)

Built-in unit

RAV-CT101BH-M

3 8,00

405 - 485 × 1105 × 720 1520 54 8.065,–

9.700,–RAV-SM804ATP-E 550 × 780 × 290 – 48 / 52 1.540,–

RBC-AMT32E – – – 95,–

TOSHIBA I 29

LIG

HT

COM

MER

CIA

L

30 I TOSHIBA

P R I C E L I S T – COMMERCIALCO

MM

ERCI

AL

Indoor units

Model typeHP 0,6 0,8 1,0 1,3 1,7 2,0 2,5 3,0 3,2 4,0 5,0 6,0 8,0 10,0

kW 1,7 2,2 2,8 3,6 4,5 5,6 7,1 8,0 9,0 11,2 14,0 16,0 22,4 28

HI-WALL

Series 4

MMK-AP(...)4MH-E

Series 3

MMK-AP(...)3H

CEILING MMC-AP(...)HP-E

CASSETTE

60 × 60 4-way Cassette

MMU-AP(...)MH-E

4-way Cassette

MMU-AP(...)HP-E

2-way Cassette

MMU-AP(...)WH

1-way Cassette

MMU-AP(...)YH/SH-E

DUCT

Slim Duct

MMD-AP(...)SPH-E

Standard Duct

MMD-AP(...)BH(P)-E

High Static Pressure Duct - Series 4

MMD-AP(...)4H-E

High Static Pressure Duct - Series 6

MMD-AP(...)6H-E

Duct with fresh air intake

MMD-AP(...)HFE

TOSHIBA I 31

COM

MER

CIA

L

HP 0,6 0,8 1,0 1,3 1,7 2,0 2,5 3,0 3,2 4,0 5,0 6,0 8,0 10,0

kW 1,7 2,2 2,8 3,6 4,5 5,6 7,1 8,0 9,0 11,2 14,0 16,0 22,4 28

CHASSIS

Chassis

MML-AP(...)BH-E

Floor

MMF-AP(...)H-E

Console

MML-AP(...)NH-E

Hot Water Module

Valve kit exhaust temperature control

Valve kit 0-10V power control

32 I TOSHIBA

P R I C E L I S T – COMMERCIALCO

MM

ERCI

AL

VRF SYSTEMS

MiNi-Super Multi System (MiNi SMMS) ■ 1-phase

■ 2-pipe heat pump system with very high efficiency up to 4,29

■ 3 compact outdoor units available in the performances from 12,1 to 15,5 kW

■ Depending on the outdoor unit up to 9 indoor units can be used

■ Very lightweight outdoor units

MiNi-Super Multi System e (MiNi SMMS-e) ■ 3-phase

■ 2-pipe heat pump system with excellent efficiencies: SEER up to 10,99, SCOP up to 7,19

■ 3 compact outdoor units available in the performances from 12,1 to 15,5 kW

■ Depending on the outdoor unit up to 13 indoor units can be used

■ Cooling to + 46°C outdoor temperature

Super Heat Recovery System i (SHRM-i) ■ 3-pipe system which enables simultaneous and independent cooling and heating

■ Very high energy efficiency (EER up to 3,7 / COP up to 4,0) by heat recovery

■ Capacity range: 8 to 42 HP (22,4 to 118 kW)

■ Maximum energy savings

■ High plant flexibility

Super Modular Multi System i (SMMS-i) ■ 2-pipe system in heat pump version

■ Capacity range: 22,4 kW (8 HP) up to 135 kW (48 HP); outdoor units with 8, 10, 12, 14 and 16 HP

■ Up to 48 indoor units can be used

■ Excellent efficiency at part load

■ Low noise level

Super Modular Multi System e (SMMS-e) ■ 2-pipe system in heat pump version

■ Capacity range: 22,4 kW (8 HP) up to 168 kW (60 HP); outdoor units 8 - 22 HP

■ Up to 64 indoor units can be used

■ Excellent efficiencies in all areas

■ Optimised Heating: more comfort in heating mode

■ IFT-Technology: the perfect refrigerant management for maximum energy savings

■ Wave Tool: wireless NFC connection for reading data on Android phone and tablet

TOSHIBA I 33

COM

MER

CIA

L

Super Modular Multi System i (SMMS-i)Outdoor units

TypeCapacity (kW) Dimensions

(H × W × D) (mm)Weight

(kg)Sound pressure (dB(A))

❄ / Price

excl. VAT (EUR)❄

Outdoor units „Heat pump“

MMY-MAP0804HT8P-E 22,40 25,00 1830 × 990 × 780 242 55 / 56 8.620,–

MMY-MAP1004HT8P-E 28,00 31,50 1830 × 990 × 780 242 57 / 58 8.990,–

MMY-MAP1204HT8P-E 33,50 37,50 1830 × 990 × 780 242 59 / 62 9.960,–

MMY-MAP1404HT8P-E 40,00 45,00 1830 × 1210 × 780 329 60 / 62 12.100,–

MMY-MAP1604HT8P-E 45,00 50,00 1830 × 1210 × 780 329 62 / 64 12.990,–

❄Cooling Heating

■ Excellent efficiencies at partial load

■ 2-pipe System

■ Highest reliability

■ Low noise level

■ Flexible scheduling options

Super Modular Multi System e (SMMS-e)Outdoor units

TypeCapacity (kW) Dimensions

(H × W × D) (mm)Weight

(kg)Sound pressure (dB(A))

❄ / Price

excl. VAT (EUR)❄

Outdoor units „Heat pump“

MMY-MAP0806HT8P-E 22,40 25,00 1830 × 990 × 780 242 55 / 56 8.990,–

MMY-MAP1006HT8P-E 28,00 31,50 1830 × 990 × 780 242 57 / 58 9.390,–

MMY-MAP1206HT8P-E 33,50 37,50 1830 × 990 × 780 242 59 / 61 10.350,–

MMY-MAP1406HT8P-E 40,00 45,00 1830 × 1210 × 780 300 60 / 62 12.640,–

MMY-MAP1606HT8P-E 45,00 50,00 1830 × 1210 × 780 300 62 / 64 13.560,–

MMY-MAP1806HT8P-E 50,40 56,00 1830 × 1600 × 780 371 60 / 61 14.750,–

MMY-MAP2006HT8P-E 56,00 63,00 1830 × 1600 × 780 371 61 / 62 15.800,–

MMY-MAP2206HT8P-E 61,50 64,00 1830 × 1600 × 780 371 61 / 62 16.850,–

❄Cooling Heating

■ ESEER values for all units over 7

■ 2-pipe System

■ Up to 64 units can be connected

■ Capacity to 22 HP with only one outdoor unit module

■ Optimized Heating

■ Wave Tool

34 I TOSHIBA

P R I C E L I S T – COMMERCIALCO

MM

ERCI

AL

Model nameCapacity (kW)

Quantity of outdoor units Max. number of indoor unitsPrice

excl. VAT (EUR)❄

MMY-MAP0804HT8P-E 22,40 25,00 1 13 8.620,–

MMY-MAP1004HT8P-E 28,00 31,50 1 16 8.990,–

MMY-MAP1204HT8P-E 33,50 37,50 1 20 9.960,–

MMY-MAP1404HT8P-E 40,00 45,00 1 23 12.100,–

MMY-MAP1604HT8P-E 45,00 50,00 1 27 12.990,–

MMY-AP1814HT8P-E 50,40 56,50 2 30 17.610,–

MMY-AP2014HT8P-E 56,00 63,00 2 33 17.980,–

MMY-AP2214HT8P-E 61,50 69,00 2 37 18.950,–

MMY-AP2414HT8P-E 68,00 76,50 2 40 19.920,–

MMY-AP2614HT8P-E 73,00 81,50 2 43 21.980,–

MMY-AP2814HT8P-E 78,50 88,00 2 47 22.950,–

MMY-AP3014HT8P-E 85,00 95,00 2 48 25.090,–

MMY-AP3214HT8P-E 90,00 100,00 2 48 25.980,–

MMY-AP3414HT8P-E 96,00 108,00 3 48 28.910,–

MMY-AP3614HT8P-E 101,00 113,00 3 48 29.880,–

MMY-AP3814HT8P-E 106,50 119,50 3 48 31.940,–

MMY-AP4014HT8P-E 112,00 127,00 3 48 32.910,–

MMY-AP4214HT8P-E 118,00 132,00 3 48 35.050,–

MMY-AP4414HT8P-E 123,50 138,00 3 48 35.940,–

MMY-AP4614HT8P-E 130,00 145,00 3 48 38.080,–

MMY-AP4814HT8P-E 135,00 150,00 3 48 38.970,–

High efficient models

MMY-AP1624HT8P-E 45,00 50,00 2 27 17.240,–

MMY-AP2424HT8P-E 68,00 76,50 3 40 25.860,–

MMY-AP2624HT8P-E 73,00 81,50 3 43 26.230,–

MMY-AP2824HT8P-E 78,50 88,00 3 47 26.600,–

MMY-AP3024HT8P-E 85,00 95,00 3 48 26.970,–

MMY-AP3224HT8P-E 90,00 100,00 4 48 34.480,–

MMY-AP3424HT8P-E 96,00 108,00 4 48 34.850,–

MMY-AP3624HT8P-E 101,00 113,00 4 48 35.220,–

MMY-AP3824HT8P-E 106,50 119,50 4 48 35.590,–

MMY-AP4024HT8P-E 112,00 127,00 4 48 35.960,–

MMY-AP4224HT8P-E 118,00 132,00 4 48 36.930,–

MMY-AP4424HT8P-E 123,50 138,00 4 48 37.900,–

MMY-AP4624HT8P-E 130,00 145,00 4 48 38.870,–

MMY-AP4824HT8P-E 135,00 150,00 4 48 39.840,–

❄ Cooling Heating

SMMS-i outdoor unit combinations

TOSHIBA I 35

COM

MER

CIA

L

Model nameCapacity (kW)

Quantity of outdoor units Max. number of indoor unitsPrice

excl. VAT (EUR)❄

MMY-MAP0806HT8P-E 22,40 25,00 1 18 8.990,–

MMY-MAP1006HT8P-E 28,00 31,50 1 22 9.390,–

MMY-MAP1206HT8P-E 33,50 37,50 1 27 10.350,–

MMY-MAP1406HT8P-E 40,00 45,00 1 31 12.640,–

MMY-MAP1606HT8P-E 45,00 50,00 1 36 13.560,–

MMY-MAP1806HT8P-E 50,40 56,00 1 40 14.750,–

MMY-MAP2006HT8P-E 56,00 63,00 1 45 15.800,–

MMY-MAP2206HT8P-E 61,50 64,00 1 49 16.850,–

MMY-AP2416HT8P-E 67,00 75,00 2 54 20.700,–

MMY-AP2616HT8P-E 73,50 82,50 2 58 22.990,–

MMY-AP2816HT8P-E 78,50 87,50 2 63 23.910,–

MMY-AP3016HT8P-E 85,00 95,00 2 64 26.200,–

MMY-AP3216HT8P-E 90,00 100,00 2 64 27.120,–

MMY-AP3416HT8P-E 95,40 106,00 2 64 28.310,–

MMY-AP3616HT8P-E 101,00 113,00 2 64 29.360,–

MMY-AP3816HT8P-E 106,50 114,00 2 64 30.410,–

MMY-AP4016HT8P-E 112,00 126,00 2 64 31.600,–

MMY-AP4216HT8P-E 117,50 127,00 2 64 32.650,–

MMY-AP4416HT8P-E 123,00 128,00 2 64 33.700,–

MMY-AP4616HT8P-E 130,00 145,00 3 64 39.760,–

MMY-AP4816HT8P-E 135,00 150,00 3 64 40.680,–

MMY-AP5016HT8P-E 140,40 156,00 3 64 41.870,–

MMY-AP5216HT8P-E 146,00 163,00 3 64 42.920,–

MMY-AP5416HT8P-E 151,50 164,00 3 64 43.970,–

MMY-AP5616HT8P-E 157,00 176,00 3 64 45.160,–

MMY-AP5816HT8P-E 162,50 177,00 3 64 46.210,–

MMY-AP6016HT8P-E 168,00 178,00 3 64 47.260,–

High efficient models

MMY-AP2026HT8P-E 56,00 63,00 2 45 18.780,–

MMY-AP2226HT8P-E 61,50 69,00 2 49 19.740,–

MMY-AP3626HT8P-E 100,50 112,50 3 64 31.050,–

MMY-AP3826HT8P-E 107,00 120,00 3 64 33.340,–

MMY-AP4026HT8P-E 113,50 127,50 3 64 35.630,–

MMY-AP4226HT8P-E 120,00 135,00 3 64 37.920,–

MMY-AP4426HT8P-E 125,00 140,00 3 64 38.840,–

MMY-AP5426HT8P-E 152,00 171,00 3 64 44.240,–

❄ Cooling Heating

SMMS-e outdoor unit combinations

36 I TOSHIBA

P R I C E L I S T – COMMERCIALCO

MM

ERCI

AL

MiNi SMMS-i 1-phase

TypeCapacity (kW) Dimensions

(H × W × D) (mm)Weight

(kg)Sound pressure

[dB(A)]Single price

excl. VAT (EUR)❄ Code (HP)

Outdoor units MiNi SMMS-i

MCY-MAP0401HT 1) 12,10 12,50 4 1340 × 900 × 320 117 67 4.100,–

MCY-MAP0501HT 2) 14,00 16,00 5 1340 × 900 × 320 117 69 4.200,–

MCY-MAP0601HT 3) 15,50 18,00 6 1340 × 900 × 320 117 70 4.600,–

1) max. 6 indoor units 2) max. 8 indoor units 3) max. 9 indoor units

■ Compact inverter operated outdoor units

■ Low noise level

■ 230 V power supply

■ Diversity 80 – 130 %

■ PMV-kit optional for noise-sensitive applications

MiNi SMMS-e 3-phase

TypeCapacity (kW) Dimensions

(H × W × D) (mm)Weight

(kg)Sound pressure[dB(A)] ❄ /

Single priceexcl. VAT (EUR)

❄ Code (HP)

Outdoor units MiNi SMMS-e

MCY-MHP0404HS8-E 1) 12,10 12,50 4 1235 × 990 × 390 125 49/52 4.400,–

MCY-MHP0504HS8-E 2) 14,00 16,00 5 1235 × 990 × 390 125 50/53 4.500,–

MCY-MHP0604HS8-E 3) 15,50 18,00 6 1235 × 990 × 390 125 51/54 4.900,–

1) max. 8 indoor units 2) max. 10 indoor units 3) max. 13 indoor units

■ Power supply 380-415V / 3Ph / 50Hz

■ Combinable up to 13 indoor units

■ ESEER values up to 10,99

■ SCOP values up to 7,19

■ VN / HEX heat exchanger and new 0,6 HP units can be connected

Optional PMV-KIT

Type Single price excl. VAT (EUR)

RBM-PMV0362E Optional valve kit for extra quiet operation, indoor unit types 007, 009, 012 215,–

RBM-PMV0902E Optional valve kit for extra quiet operation, indoor unit types 015, 018, 024 240,–

TOSHIBA I 37

COM

MER

CIA

L

Super-Heat Recovery Multi System i (SHRM-i)Outdoor units

TypeCapacity (kW) Dimensions

(H × W × D) (mm)Weight

(kg)Sound pressure

[dB(A)]Single price

excl. VAT (EUR)❄ Code (HP)

Outdoor units SHRM-i

MMY-MAP0804FT8-E 22,40 25,00 8 1830 × 990 × 780 259 55/57 10.800,–

MMY-MAP1004FT8-E 28,00 31,50 10 1830 × 990 × 780 259 57/59 12.150,–

MMY-MAP1204FT8-E 33,50 37,50 12 1830 × 1210 × 780 334 60/62 16.450,–

MMY-MAP1404FT8-E 40,00 45,00 14 1830 × 1210 × 780 334 62/64 17.550,–

❄ Cooling Heating

■ 3-pipe heat recovery system

■ Simultaneous heating and cooling

■ Indoor units and control systems for SHRM-i are identical with those of SMMS-i systems

SHRM-i outdoor unit combinations

Model nameCapacity (kW)

Quantity of outdoor units Max. number of indoor unitsPrice

excl. VAT (EUR)❄

MMY-AP1614FT8-E 45,00 50,00 2 27 21.600,–

MMY-AP1814FT8-E 50,40 56,50 2 30 22.950,–

MMY-AP2014FT8-E 56,00 63,00 2 33 24.300,–

MMY-AP2214FT8-E 61,50 69,00 2 37 28.600,–

MMY-AP2414FT8-E 68,00 76,50 2 40 29.700,–

MMY-AP2614FT8-E 73,00 81,50 2 43 34.000,–

MMY-AP2814FT8-E 78,50 88,00 2 47 35.100,–

MMY-AP3014FT8-E 85,00 95,00 3 48 36.450,–

MMY-AP3214FT8-E 90,00 100,00 3 48 40.750,–

MMY-AP3414FT8-E 96,00 108,00 3 48 41.850,–

MMY-AP3614FT8-E 101,00 113,00 3 48 46.150,–

MMY-AP3814FT8-E 106,50 119,50 3 48 47.250,–

MMY-AP4014FT8-E 112,00 127,00 3 48 51.550,–

MMY-AP4214FT8-E 118,00 132,00 3 48 52.650,–

SHRM-i refrigerant flow selectors

TypeConnectable indoor

unit typesDimensions

(H × W × D) (mm)Weight

(kg)Single price

excl. VAT (EUR)

RBM-Y1123FE 007 - 030 190 × 250 × 160 5 750,–

RBM-Y1803FE 036 - 056 190 × 250 × 160 5 800,–

RBM-Y2803FE 072 - 096 200 × 377 × 200 8 1.400,–

RBC-FSEX15 Conncetion cable, 15 m (not in stock) 100,–

❄ Cooling Heating

38 I TOSHIBA

P R I C E L I S T – COMMERCIALCO

MM

ERCI

AL

VRF Hi-wall – Series 3

TypeCapacity (kW)* Dimensions

(H × W × D) (mm)Air flow volume (max.) (m³/h)

Sound pressure**[dB(A)]

Single priceexcl. VAT (EUR)

❄ Code (HP)

Hi-wall

MMK-AP0073H 2,20 2,50 0,8 320 × 1050 × 228 570 35 / 28 780,–

MMK-AP0093H 2,80 3,20 1 320 × 1050 × 228 600 37 / 28 790,–

MMK-AP0123H 3,60 4,00 1,25 320 × 1050 × 228 600 37 / 28 800,–

MMK-AP0153H 4,50 5,00 1,7 320 × 1050 × 228 840 41 / 33 895,–

MMK-AP0183H 5,60 6,30 2,0 320 × 1050 × 228 840 41 / 33 920,–

MMK-AP0243H 7,10 8,00 2,5 320 × 1050 × 228 1020 46 / 34 930,–

❄ Cooling Heating

* Standard cable lengths 5 m main lines, branch lines 2,5 m, 0 m height difference ** Specification with the highest / lowest fan speed

■ Simple, elegant design with a flat panel

■ Same dimensions for all types

■ Infrared remote control included

VRF Hi-wall – Series 3 with external PMV kit

TypeCapacity (kW)* Dimensions

(H × W × D) (mm)Air flow volume (max.) (m³/h)

Sound pressure**[dB(A)]

Single price excl. VAT (EUR)

Set priceexcl. VAT (EUR)

❄ Code (HP)

Hi-wall

MMK-AP0073HP-E1 2,20 2,50 0,8 320 × 1050 × 228 570 35 / 28 780,–995,–

RBM-PMV0363E 215,–

MMK-AP0093HP-E1 2,80 3,20 1 320 × 1050 × 228 600 37 / 28 790,–1.005,–

RBM-PMV0363E 215,–

MMK-AP0123HP-E1 3,60 4,00 1,25 320 × 1050 × 228 600 37 / 28 800,–1.015,–

RBM-PMV0363E 215,–

MMK-AP0153HP-E1 4,50 5,00 1,7 320 × 1050 × 228 840 41 / 33 895,–1.135,–

RBM-PMV0903E 240,–

MMK-AP0183HP-E1 5,60 6,30 2,0 320 × 1050 × 228 840 41 / 33 920,–1.160,–

RBM-PMV0903E 240,–

MMK-AP0243HP-E1 7,10 8,00 2,5 320 × 1050 × 228 1020 46 / 34 930,–1.170,–

RBM-PMV0903E 240,–

❄ Cooling Heating

* Standard cable lengths 5 m main lines, branch lines 2,5 m, 0 m height difference ** Specification with the highest / lowest fan speed

■ Series E1 without built-in Pulse motor valve

■ Extremely quiet

■ Must be installed exclusively in connection with the PMV kit!

■ Especially for noise-sensitive applications

TOSHIBA I 39

COM

MER

CIA

L

VRF Hi-wall – Series 4

TypeCapacity (kW)* Dimensions

(H × W × D) (mm)Air flow volume (max.) (m³/h)

Sound pressure**[dB(A)]

Single priceexcl. VAT (EUR)

❄ Code (HP)

Hi-wall

MMK-AP0054MHP-E* 1,70 1,90 0,6 275 × 790 × 208 445 33 / 29 760,–

* Combinable only with outdoor units of Series-e!

MMK-AP0074MH-E 2,20 2,50 0,8 275 × 790 × 208 480 35 / 29 780,–

MMK-AP0094MH-E 2,80 3,20 1 275 × 790 × 208 510 36 / 29 790,–

MMK-AP0124MH-E 3,60 4,00 1,25 275 × 790 × 208 540 37 / 29 800,–

■ Modern design

■ Very compact dimensions

■ Infrared remote control with a 24-hours timer included

VRF Hi-wall – Series 4with external PMV kit

TypeCapacity (kW)* Dimensions

(H × W × D) (mm)Air flow volume (max.) (m³/h)

Sound pressure**[dB(A)]

Single price excl. VAT (EUR)

Set priceexcl. VAT (EUR)

❄ Code (HP)

Hi-wall

MMK-AP0054MHP-E1* 1,70 1,90 0,6 275 × 790 × 208 445 33 / 29 760,–975,–

RBM-PMV0363E 215,–

* Combinable only with outdoor units of Series-e!

MMK-AP0074MHP-E1 2,20 2,50 0,8 275 × 790 × 208 480 35 / 29 780,–995,–

RBM-PMV0363E 215,–

MMK-AP0094MHP-E1 2,80 3,20 1 275 × 790 × 208 510 36 / 29 790,–1.005,–

RBM-PMV0363E 215,–

MMK-AP0124MHP-E1 3,60 4,00 1,25 275 × 790 × 208 540 37 / 29 800,–1.015,–

RBM-PMV0363E 215,–

❄ Cooling Heating

■ Series E1 without built-in Pulse motor valve

■ Extremely quiet

■ Must be installed exclusively in connection with the PMV kit!

■ Especially for noise-sensitive applications

40 I TOSHIBA

P R I C E L I S T – COMMERCIALCO

MM

ERCI

AL

VRF Ceiling

■ New, elegant design with large air conducting strip for optimum air distribution in the room

■ Higher efficiency through the use of a new heat exchanger

■ More air volume with simultaneous noise reduction

■ Easy installation

TypeCapacity (kW)* Dimensions

(H × W × D) (mm)Air flow volume (max.) (m³/h)

Sound pressure**[dB(A)]

Single priceexcl. VAT (EUR)

❄ Code (HP)

Ceiling

MMC-AP0157HP-E 4,50 5,00 1,7 235 × 950 × 690 840 36 / 28 1.290,–

MMC-AP0187HP-E 5,60 6,30 2 235 × 950 ×690 960 37 / 28 1.360,–

MMC-AP0247HP-E 7,10 8,00 2,5 235 × 1270 × 690 1.440 41 / 29 1.430,–

MMC-AP0277HP-E 8,00 9,00 3 235 × 1270 × 690 1.440 41 / 29 1.540,–

MMC-AP0367HP-E 11,20 12,50 4 235 × 1586 × 690 1.860 44 / 32 1.690,–

MMC-AP0487HP-E 14,00 16,00 5 235 × 1586 × 690 1.860 44 / 35 1.890,–

MMC-AP0567HP-E 16,00 18,00 6 235 × 1586 × 690 2.040 46 / 36 1.990,–

TCB-DP31CE Drain pump; Lift 600 mm, measured from the bottom edge of the unit 290,–

TCB-KP13CE Elbow piping kit; MMC-AP0157/0187HP-E 80,–

TCB-KP23CE Elbow piping kit; MMC-AP0247 - 0567HP-E 95,–

TCB-PCUC1E Control kit (Functions: Analog inputs and digital inputs / outputs for external control, alarms and messages) 130,–

❄ Cooling Heating

* Standard cable lengths 5 m main lines, branch lines 2,5 m, 0 m height difference ** Specification with the highest / lowest fan speed

Accessories

Type Single price excl. VAT (EUR)

TCB-FF101URE2 Spigot for fresh air intake Ø 100 mm 55,–

TOSHIBA I 41

COM

MER

CIA

L

VRF Slim Duct

VRF Standard Duct

TypeCapacity (kW)* Dimensions

(H × W × D) (mm)Air flow volume (max.) (m³/h)

Sound pressure (dB(A))** Single priceexcl. VAT (EUR)

❄ Code (HP) lower air intake upper air intake

Slim Duct

MMD-AP0054SPH-E* 1,70 1,90 0,6 210 × 845 × 645 490 35 / 30 27 / 24 1.260,–

* Combinable only with outdoor units of Series-i!

MMD-AP0056SPH-E* 1,70 1,90 0,6 210 × 845 × 645 435 33 / 30 26 / 24 1.260,–

* Combinable only with outdoor units of Series-e!

MMD-AP0074SPH-E 2,20 2,50 0,8 210 × 845 × 645 540 36 / 30 28 / 24 1.300,–

MMD-AP0094SPH-E 2,80 3,20 1 210 × 845 × 645 540 36 / 30 28 / 24 1.330,–

MMD-AP0124SPH-E 3,60 4,00 1,25 210 × 845 × 645 600 38 / 32 29 / 25 1.400,–

MMD-AP0154SPH-E 4,50 5,00 1,7 210 × 845 × 645 690 39 / 33 32 / 28 1.460,–

MMD-AP0184SPH-E 5,60 6,30 2 210 × 845 × 645 780 40 / 36 33 / 29 1.530,–

MMD-AP0244SPH-E 7,10 8,00 2,5 210 × 1140 × 645 1080 49 / 44 38 / 33 1.650,–

MMD-AP0274SPH-E 8,00 9,00 3 210 × 1140 × 645 1080 49 / 44 38 / 33 1.780,–

* Standard cable lengths 5 m main lines, branch lines 2,5 m, 0 m height difference ** Specification with the highest / lowest fan speed

TypeCapacity (kW)* Dimensions

(H × W × D) (mm)Air flow volume (max.) (m³/h)

Sound pressure**[dB(A)]

Single priceexcl. VAT (EUR)

❄ Code (HP)

Standard Duct

MMD-AP0076BHP-E 2,20 2,50 0,8 275 × 700 × 750 540 29 / 23 1.230,–

MMD-AP0096BHP-E 2,80 3,20 1 275 × 700 × 750 570 30 / 23 1.240,–

MMD-AP0126BHP-E 3,60 4,00 1,25 275 × 700 × 750 570 30 / 23 1.260,–

MMD-AP0156BHP-E 4,50 5,00 1,7 275 × 700 × 750 800 33 / 25 1.300,–

MMD-AP0186BHP-E 5,60 6,30 2 275 × 700 × 750 800 33 /25 1.350,–

MMD-AP0246BHP-E 7,10 8,00 2,5 275 × 1000 × 750 1200 36 /27 1.500,–

MMD-AP0276BHP-E 8,00 9,00 3 275 × 1000 × 750 1200 36 / 27 1.560,–

MMD-AP0306BHP-E 9,00 10,00 3,2 275 × 1000 × 750 1260 36 / 27 1.700,–

MMD-AP0366BHP-E 11,20 12,50 4 275 × 1400 × 750 1920 40 / 33 1.860,–

MMD-AP0486BHP-E 14,00 16,00 5 275 × 1400 × 750 2100 40 / 33 2.000,–

MMD-AP0566BHP-E 16,00 18,00 6 275 × 1400 × 750 2100 40 / 33 2.200,–

❄ Cooling Heating

* Standard cable lengths 5 m main lines, branch lines 2,5 m, 0 m height difference ** Specification with the highest / lowest fan speed

Accessories

Type Compatible Single price excl. VAT (EUR)

TCB-SF56C6BPE Flange MMD-AP0076/0096/0126/0156/0186BH-E (2 × Ø 200 mm) 120,–

TCB-SF80C6BPE Flange MMD-AP0246/0276/0306BH-E (3 × Ø 200 mm) 145,–

TCB-SF160C6BPE Flange MMD-AP0366/0486/0566BH-E (4 × Ø 200 mm) 180,–

TCB-FF101URE2 Spigot for fresh air intake Ø 100 mm (for Slim Duct and Standard Duct) 55,–

■ Height of only 210 mm

■ Drain pump with 850 mm lifting height included (measured from bottom edge of unit)

■ Air supply from below or behind possible, filter for rear air supply including

■ Air supply from below or behind possible, filter for rear air supply including

■ Drain pump with 850 mm lifting height included (measured from bottom edge of unit)

■ Easy installation

42 I TOSHIBA

P R I C E L I S T – COMMERCIALCO

MM

ERCI

AL

VRF High Static Pressure Duct

TypeCapacity (kW)* Dimensions

(H × W × D) (mm)Air flow volume

(Standard) (m³/h)Sound pressure

[dB(A)]Single price

excl. VAT (EUR)❄ Code (HP)

High Static Pressure Duct

MMD-AP0184H-E 5,60 6,30 2 380 × 850 × 660 900 37 1.790,–

MMD-AP0244H-E 7,10 8,00 2,5 380 × 850 × 660 1320 40 1.955,–

MMD-AP0274H-E 8,00 9,00 3 380 × 850 × 660 1320 40 2.040,–

MMD-AP0364H-E 11,20 12,50 4 380 × 850 × 660 1600 40 2.130,–

MMD-AP0484H-E 14,00 16,00 5 380 × 1200 × 660 2100 40 2.235,–

MMD-AP0724H-E 22,40 25,00 8 470 × 1380 × 1250 3600 49 4.890,–

MMD-AP0964H-E 28,00 31,50 10 470 × 1380 × 1250 4200 50 5.100,–

* Standard cable lengths 5 m main lines, branch lines 2,5 m, 0 m height difference

Accessories

Type Single price excl. VAT (EUR)

TCB-DP31DE Drain pump for size 184-484 1.200,–

TCB-DP32DE Drain pump for size 724-964 1.200,–

■ Small design

■ Low weight

■ Drain pump with 850 mm lifting height included (measured from bottom edge of unit)

TypeCapacity (kW)* Dimensions

(H × W × D) (mm)Air flow volume

(Standard) (m³/h)Sound pressure

[dB(A)]Single price

excl. VAT (EUR)❄ Code (HP)

High Static Pressure Duct

MMD-AP0186HP-E 5,60 6,30 2 298 × 1000 × 750 800 37 1.790,–

MMD-AP0246HP-E 7,10 8,00 2,5 298 × 1000 × 750 1200 38 1.955,–

MMD-AP0276HP-E 8,00 9,00 3 298 × 1000 × 750 1200 38 2.040,–

MMD-AP0366HP-E 11,20 12,50 4 298 × 1400 × 750 1920 41 2.130,–

MMD-AP0486HP-E 14,00 16,00 5 298 × 1400 × 750 2100 42 2.235,–

MMD-AP0566HP-E 16,00 18,00 6 298 × 1400 × 750 2400 45 2.400,–

MMD-AP0726HP-E 22,40 25,00 8 448 × 1400 × 900 3800 44 4.890,–

MMD-AP0966HP-E 28,00 31,50 10 448 × 1400 × 900 4800 46 5.100,–

■ External static pressure up to 196 Pa

■ Inspection hole for easier maintenance

■ Perfect air distribution over multiple air outlets possible

❄ Cooling Heating

Series 6

Series 4 (Discontinued model - while stocks last)

TOSHIBA I 43

COM

MER

CIA

L

VRF Duct with fresh air intake

TypeCapacity (kW)* Dimensions

(H × W × D) (mm)Air flow volume (max.)

(m³/h)Sound pressure**

[dB(A)]Single price

excl. VAT (EUR)❄ Code (HP)

Duct with fresh air intake

MMD-AP0481HFE 14,00 8,90 5 492 × 1392 × 1262 1080 45 / 41 2.550,–

MMD-AP0721HFE 22,40 13,90 8 492 × 1392 × 1262 1680 46 / 44 5.100,–

MMD-AP0961HFE 28,00 17,40 10 492 × 1392 × 1262 2100 46 / 44 5.500,–

❄ Cooling Heating

Accessories

Type Single price excl. VAT (EUR)

TCB-DP32DFE Drain pump 680,–

* Standard cable lengths 5 m main lines, branch lines 2,5 m, 0 m height difference

Nominal conditions:Cooling: Outdoor temperature 33°C DB / 28°C WB, Setpoint temperature 18°CHeating: Outdoor temperature 0°C DB / -2,9°C WB, Setpoint temperature 25°CRefrigerant pipe: Length 7,5 m / Height 0 m

** Specification with the highest / lowest fan speed

■ Perfect solution for an increased need for fresh air

■ Preheating and precooling

■ Unit can only be used in combination with other VRF master indoor units!

44 I TOSHIBA

P R I C E L I S T – COMMERCIALCO

MM

ERCI

AL

VRF 60×60 4-way Cassette

VRF 4-way Cassette – Standard

TypeCapacity (kW)* Dimensions

(H × W × D) (mm)Air flow volume (max.) (m³/h)

Sound pressure** [dB(A)]

Single priceexcl. VAT (EUR)

❄ Code (HP)

Compact 4-way Cassette 60 × 60

MMU-AP0054MH-E* 1,70 1,90 0,6 268 × 575 × 575 486 35 / 28 1.250,–* Combinable only with outdoor units of Series-i!

MMU-AP0056MH-E* 1,70 1,90 0,6 268 × 575 × 575 430 32 / 28 1.250,–* Combinable only with outdoor units of Series-e!

MMU-AP0074MH-E 2,20 2,50 0,8 268 × 575 × 575 552 36 / 38 1.290,–

MMU-AP0094MH-E 2,80 3,20 1 268 × 575 × 575 570 37 / 28 1.390,–

MMU-AP0124MH-E 3,60 4,00 1,25 268 × 575 × 575 594 37 / 29 1.450,–

MMU-AP0154MH-E 4,50 5,00 1,7 268 × 575 × 575 660 40 / 30 1.530,–

MMU-AP0184MH-E 5,6 6,30 2 268 × 575 × 575 762 44 / 34 1.590,–

Panel

RBC-UM11PG(W)-E – – – 27 × 700 × 700 – – 310,–

TypeCapacity (kW)* Dimensions

(H × W × D) (mm)Air flow volume (max.) (m³/h)

Sound pressure**[dB(A)]

Single priceexcl. VAT (EUR)

❄ Code (HP)

4-way Cassette

MMU-AP0094HP-E 2,80 3,20 1 256 × 840 × 840 800 30 / 27 1.150,–

MMU-AP0124HP-E 3,60 4,00 1,25 256 × 840 × 840 800 30 / 37 1.190,–

MMU-AP0154HP-E 4,50 5,00 1,7 256 × 840 × 840 930 31 / 27 1.240,–

MMU-AP0184HP-E 5,60 6,30 2 256 × 840 × 840 1050 32 / 27 1.280,–

MMU-AP0244HP-E 7,10 8,00 2,5 256 × 840 × 840 1290 35 / 28 1.340,–

MMU-AP0274HP-E 8,00 9,00 3 256 × 840 × 840 1290 35 / 28 1.410,–

MMU-AP0304HP-E 9,00 10,00 3,2 256 × 840 × 840 1320 38 / 30 1.490,–

MMU-AP0364HP-E 11,20 12,50 4 319 × 840 × 840 1970 43 / 32 1.750,–

MMU-AP0484HP-E 14,00 16,00 5 319 × 840 × 840 2130 46 / 33 1.920,–

MMU-AP0564HP-E 16,00 18,00 6 319 × 840 × 840 2130 46 / 33 2.000,–

Panels

RBC-U31PGP(W)-E for wide airflow 30 × 950 × 950 – – 280,–

RBC-U31PGSP(W)-E for direct airflow 30 × 950 × 950 – – 300,–

❄ Cooling Heating

* Standard cable lengths 5 m main lines, branch lines 2,5 m, 0 m height difference ** Specification with the highest / lowest fan speed

■ Designed for euro-grid suspended ceilings

■ Drain pump with 850 mm lifting height included (measured from bottom edge of unit)

■ Height of only 268 mm

■ Fresh air intake possible with external fan to 15% of the nominal amount of air in the indoor unit

■ Choice of 2 different panels

■ Drain pump with 850 mm lifting height included (measured from bottom edge of unit)

■ Fresh air intake possible with external fan to 15% of the nominal amount of air in the indoor unit

■ Individual air flow for optimal, draft-free air distribution

Accessories

Type Single price excl. VAT (EUR)

TCB-FF101URE2Spigot for fresh air intake Ø 100 mm

(for 60×60 4-way cassette and 4-way cassette - Standard)55,–

TOSHIBA I 45

COM

MER

CIA

L

VRF 2-way Cassette

■ Small sizes available (from 2,2 kW upwards)

■ Very quiet operation

■ Fresh air intake possible with external fan to 15% of the nominal amount of air in the indoor unit

■ Drain pump with 850 mm lifting height included (measured from bottom edge of unit)

TypeCapacity (kW)* Dimensions

(H × W × D) (mm)Air flow volume (max.) (m³/h)

Sound pressure** [dB(A)]

Single priceexcl. VAT (EUR)

❄ Code (HP)

2-way Cassette

MMU-AP0072WH 2,20 2,50 0,8 295 × 815 × 570 558 34 / 30 1.300,–

MMU-AP0092WH 2,80 3,20 1,0 295 × 815 × 570 558 34 / 30 1.350,–

MMU-AP0122WH 3,60 4,00 1,25 295 × 815 × 570 558 34 / 30 1.380,–

MMU-AP0152WH 4,50 5,00 1,7 295 × 815 × 570 600 35 / 30 1.420,–

MMU-AP0182WH 5,60 6,30 2,0 345 × 1180 × 570 900 35 / 30 1.460,–

MMU-AP0242WH 7,10 8,00 2,5 345 × 1180 × 570 1050 38 / 33 1.550,–

MMU-AP0272WH 8,00 9,00 3,0 345 × 1180 × 570 1050 38 / 33 1.600,–

MMU-AP0302WH 9,00 10,00 3,2 345 × 1180 × 570 1260 40 / 34 1.730,–

MMU-AP0362WH 11,20 12,50 4,0 345 × 1600 × 570 1740 42 / 36 2.070,–

MMU-AP0482WH 14,00 16,00 5,0 345 × 1600 × 570 1800 43 / 37 2.250,–

MMU-AP0562WH 16,00 18,00 6,0 345 × 1600 × 570 2040 46 / 39 2.490,–

Panels

RBC-UW283PG(W)-E MMU-AP0072 - 0152WH 20 × 1050 × 680 – – 390,–

RBC-UW803PG(W)-E MMU-AP0182 - 0302WH 20 × 1415 × 680 – – 520,–

RBC-UW1403PG(W)-E MMU-AP0362 - 0562WH 20 × 1835 × 680 – – 600,–

❄ Cooling Heating

* Standard cable lengths 5 m main lines, branch lines 2,5 m, 0 m height difference ** Specification with the highest / lowest fan speed

Accessories

Type Single price excl. VAT (EUR)

TCB-FF151US-E Spigot for fresh air intake Ø 150 mm 60,–

46 I TOSHIBA

P R I C E L I S T – COMMERCIALCO

MM

ERCI

AL

VRF 1-way Cassette

VRF Chassis

■ Small sizes available (from 2,2 kW upwards)

■ Very quiet operation

■ Drain pump with 850 mm lifting height included (measured from bottom edge of unit)

■ Fresh air intake possible with external fan to 15% of the nominal amount of air in the indoor unit

TypeCapacity (kW)* Dimensions

(H × W × D) (mm)Air flow volume (max.) (m³/h)

Sound pressure**[dB(A)]

Single priceexcl. VAT (EUR)

❄ Code (HP)

1-way Cassette

MMU-AP0074YH-E 2,20 2,50 0,8 235 × 850 × 400 540 42 / 34 1.480,–

MMU-AP0094YH-E 2,80 3,20 1 235 × 850 × 400 540 42 / 34 1.500,–

MMU-AP0124YH-E 3,60 4,00 1,25 235 × 850 × 400 540 42 / 34 1.530,–

MMU-AP0154SH-E 4,50 5,00 1,7 200 × 1000 × 710 750 37 / 32 1.420,–

MMU-AP0184SH-E 5,60 6,30 2 200 × 1000 × 710 780 38 / 34 1.580,–

MMU-AP0244SH-E 7,10 8,00 2,5 200 × 1000 × 710 1140 45 / 37 1.680,–

Panels

RBC-UY136PG MMU-AP0074/0094/0124YH-E 18 × 1050 × 470 – – 380,–

RBC-US21PGE MMU-AP0154/0184/0244SH-E 20 × 1230 × 800 – – 440,–

* Standard cable lengths 5 m main lines, branch lines 2,5 m, 0 m height difference ** Specification with the highest / lowest fan speed

TypeCapacity (kW)* Dimensions

(H × W × D) (mm)Air flow volume (max.) (m³/h)

Sound pressure**[dB(A)]

Single priceexcl. VAT (EUR)

❄ Code (HP)

Chassis

MML-AP0074BH-E 2,20 2,50 0,8 600 × 745 × 220 460 36 / 32 1.430,–

MML-AP0094BH-E 2,80 3,20 1 600 × 745 × 220 460 36 / 32 1.450,–

MML-AP0124BH-E 3,60 4,00 1,25 600 × 745 × 220 460 36 / 32 1.500,–

MML-AP0154BH-E 4,50 5,00 1,7 600 × 1045 × 220 740 36 / 32 1.530,–

MML-AP0184BH-E 5,60 6,30 2 600 × 1045 × 220 740 36 / 32 1.550,–

MML-AP0244BH-E 7,10 8,00 2,5 600 × 1045 × 220 950 42 / 33 1.580,–

❄ Cooling Heating

* Standard cable lengths 5 m main lines, branch lines 2,5 m, 0 m height difference ** Specification with the highest / lowest fan speed

Accessories

Type Single price excl. VAT (EUR)

TCB-FF101URE2 Spigot for fresh air intake Ø 100 mm 55,–

■ Perfect for offices and other commercial buildings

■ Through complete shoring no influence on the interior

TOSHIBA I 47

COM

MER

CIA

L

VRF Console

VRF Floor

■ Bi-flow console with air outlet at the top and/or at the bottom

■ Large centrifugal fan for extra quiet operation

■ Infrared remote control included

■ Easy installation because of flexible connection variations

■ Air outlet from the front or the rear

TypeCapacity (kW)* Dimensions

(H × W × D) (mm)Air flow volume (max.) (m³/h)

Sound pressure**[dB(A)]

Single priceexcl. VAT (EUR)

❄ Code (HP)

Console

MML-AP0074NH-E 2,20 2,50 0,8 600 × 700 × 220 510 38 / 26 1.120,–

MML-AP0094NH-E 2,80 3,20 1 600 × 700 × 220 510 38 / 26 1.180,–

MML-AP0124NH-E 3,60 4,00 1,25 600 × 700 × 220 552 40 / 29 1.250,–

MML-AP0154NH-E 4,50 5,00 1,7 600 × 700 × 220 624 43 / 31 1.340,–

MML-AP0184NH-E 5,60 6,30 2 600 × 700 × 220 726 47 / 34 1.390,–

TypeCapacity (kW)* Dimensions

(H × W × D) (mm)Air flow volume (max.) (m³/h)

Sound pressure**[dB(A)]

Single priceexcl. VAT (EUR)

❄ Code (HP)

Floor

MMF-AP0156H-E 4,50 5,00 1,7 1750 × 600 × 210 900 46 / 37 2.110,–

MMF-AP0186H-E 5,60 6,30 2 1750 × 600 × 210 900 46 / 37 2.140,–

MMF-AP0246H-E 7,10 8,00 2,5 1750 × 600 × 210 1200 49 / 39 2.230,–

MMF-AP0276H-E 8,00 9,00 3 1750 × 600 × 210 1200 49 / 39 2.240,–

MMF-AP0366H-E 11,20 12,50 4 1750 × 600 × 390 1920 51 / 41 2.400,–

MMF-AP0486H-E 14,00 16,00 5 1750 × 600 × 390 2160 54 / 44 2.430,–

MMF-AP0566H-E 16,00 18,00 6 1750 × 600 × 390 2160 54 / 44 2.450,–

❄ Cooling Heating Not in stock - delivery time for floor units on request

* Standard cable lengths 5 m main lines, branch lines 2,5 m, 0 m height difference ** Specification with the highest / lowest fan speed

48 I TOSHIBA

P R I C E L I S T – COMMERCIALCO

MM

ERCI

AL

VRF Valve kit for exhaust temperature control

■ DX kit consisting of electronic control box, PC board, transformer, wired remote control, PMV motor, all necessary sensors and installation manual

■ Used in conjunction with ventilation systems and air curtains

■ Wired remote control required for startup

TypeSingle price

excl. VAT (EUR)

MM-DXC010 Control unit (Master) 1.000,–

MM-DXC012 Control unit (Follower) 770,–

MM-DXV080 Valve kit up to 8 kW 460,–

MM-DXV140 Valve kit up to 14 kW 460,–

MM-DXV280 Valve kit up to 28 kW 460,–

VRF Valve kit for power control 0-10V

■ DX kit consisting of electronic control box, PC board, transformer, PMV motor, all necessary sensors and installation manual

■ Used in conjunction with ventilation systems and air curtains

■ Wired remote control required for startup

TypeSingle price

excl. VAT (EUR)

RBC-DXC031 Control unit for power control through 0-10 V signal 1.150,–

MM-DXV141 Valve kit for 11,2 kW, 14,0 kW and 16,0 kW 290,–

MM-DXV281 Valve kit for 22,4 kW and 28,0 kW 290,–

Controller for DC coil of the ventilation unit

Ventilation unit (provided on site)

Outdoor unit 8 or 10 HP SMMS-e

Controller for DC coil of the ventilation unit

Outdoor unit Ventilation unit (provided on site)

Piping

Indoor unit ControllerController

TOSHIBA I 49

COM

MER

CIA

L

VRF Hot Water Module

■ Highly efficient space heating and domestic hot water

■ Water outlet temperature range of +25 - +50°C

■ Electric backup heater support is provided externally

■ Very wide operating range for heating water and domestic hot water

■ Space-saving design

■ Leaving water temperature control

■ Connectable to all SMMS-i/-e units

ModelHeating capacity

[kW]Water flow

Standard / Min. [l/min]Dimensions

(H × W × D) (mm)Water temperature

Single priceexcl. VAT (EUR)

MMW-AP0271LQ-E 8,00 22,90 / 19,50 580 x 400 x 250 25-50°C 3.100,–

MMW-AP0561LQ-E 16,00 45,80 / 38,90 580 x 400 x 250 25-50°C 3.200,–

Air handling units with recuperator

■ Ventilation with heat recovery

■ High-efficient fresh air supply

■ Up to 75 % of the energy can be recovered

■ TCC-link-connection for connection to BMS systems

TypeCapacity DX (WRG) Capacity DX (WRG)

Air flow volume(m3/h) hoch

Dimensions(H × W × D) (mm)

Pipe connection

(mm)Single price

excl. VAT (EUR)❄

Air handling unit with recuperator

VN-M150HE --- --- 150 290 × 900 × 900 100 1.680,–

VN-M250HE --- --- 250 290 × 900 × 900 150 1.720,–

VN-M350HE --- --- 350 290 × 900 × 900 150 1.840,–

VN-M500HE --- --- 500 350 × 1140 × 1140 200 2.350,–

VN-M650HE --- --- 650 350 × 1140 × 1140 200 2.800,–

VN-M800HE --- --- 800 400 × 1189 × 1189 250 3.250,–

VN-M1000HE --- --- 1000 400 × 1189 × 1189 250 3.700,–

VN-M1500HE --- --- 1500 810 × 1189 × 1189 250 6.150,–

VN-M2000HE --- --- 2000 810 × 1189 × 1189 250 7.100,–

Air handling unit with recuperator and DX coil

MMD-VN502HEXE * 4,10 (1,30) 5,53 (2,33) 500 430 × 1140 × 1690 200 4.250,–

MMD-VN802HEXE * 6,56 (2,06) 8,61 (3,61) 800 430 × 1189 × 1739 250 5.100,–

MMD-VN1002HEXE * 8,25 (2,32) 10,92 (4,32) 950 430 × 1189 × 1739 250 5.950,–

Air handling unit with recuperator, DX coil and humidifier

MMD-VNK502HEXE * 4,10 (1,30) 5,53 (2,33) 500 430 × 1140 × 1690 200 5.650,–

MMD-VNK802HEXE * 6,56 (2,06) 8,61 (3,61) 800 430 × 1189 × 1739 250 7.600,–

MMD-VNK1002HEXE * 8,25 (2,32) 10,92 (4,32) 350 430 × 1189 × 1739 250 8.800,–

* only in conjunction with SMMS-i /-e outdoor units

Accessories

Type Single price excl. VAT (EUR)

TCB-DP31HEXE Drain pump for all ventilation systems of series „-HEXE“ 650,–

NRC-01HE Remote control 110,–

NRB-1HE ON/OFF, bypass, Low/High adapter for Air handling unit with recuperator 110,–

50 I TOSHIBA

P R I C E L I S T – COMMERCIALCO

MM

ERCI

AL

SMMS-i / SMMS-e / MiNi-SMMS-i / MiNi-SMMS-e (2-pipe-system): Branching Joints and Headers

SHRM-i (3-pipe-system): Branching Joints and Headers

Type DescriptionConnected indoor unit capacity Single price

excl. VAT (EUR)(kW) (HP)

Y-shape (two Y-shapes in each packing unit)

RBM-BY55E

Y- shape

< 18 kW < 6,4 kW 90,–

RBM-BY105E 18 kW < Capacity < 37 kW 6,4 < Capacity < 14,2 100,–

RBM-BY205E 37 kW < Capacity < 71 kW 14,2 < Capacity < 25,2 180,–

RBM-BY305E 71 kW < Capacity 25,2 < Capacity 225,–

4/8-Branch Header (two 4/8-branch headers in each packing unit)

RBM-HY1043E4-Branch Header

18 kW < Capacity < 37 kW 6,4 < Capacity < 14,2 210,–

RBM-HY2043E 37 kW < Capacity < 71 kW 14,2 < Capacity < 25,2 230,–

RBM-HY1083E8-Branch Header

18 kW < Capacity < 37 kW 6,4 < Capacity < 14,2 340,–

RBM-HY2083E 37 kW < Capacity < 71 kW 14,2 < Capacity < 25,2 400,–

T-Joints (two T-joints in each packing unit)

RBM-BT14E T-shaped connector; in conjunction with 8/10/12 HP units 290,–

RBM-BT24E T-shaped connector; in conjunction with 14/16 HP units 330,–

Type DescriptionConnected indoor unit capacity Single price

excl. VAT (EUR)(kW) (HP)

Y-shape (three Y-shapes in each packing unit)

RBM-BY55FE

Y- shape

< 18 kW < 6,4 kW 130,–

RBM-BY105FE 18 kW < Capacity < 37 kW 6,4 < Capacity < 14,2 150,–

RBM-BY205FE 37 kW < Capacity < 71 kW 14,2 < Capacity < 25,2 210,–

RBM-BY305FE 71 kW < Capacity 25,2 < Capacity 290,–

4/8-Branch Header (three 4/8-branch headers in each packing unit)

RBM-HY1043FE4-Branch Header

< 37 kW < 14,2 400,–

RBM-HY2043FE 37 kW < Capacity < 71 kW 14,2 < Capacity < 25,2 430,–

RBM-HY1083FE8-Branch Header

< 37 kW < 14,2 540,–

RBM-HY2083FE 37 kW < Capacity < 71 kW 14,2 < Capacity < 25,2 580,–

T-Joints (three T-joints in each packing unit)

RBM-BT14FE T-shaped connector (till 26 HP) 290,–

RBM-BT24FE T-shaped connector (from 26 HP) 340,–

TOSHIBA I 51

COM

MER

CIA

L

52 I TOSHIBA

P R I C E L I S T – CONTROLSCO

NTR

OLS

TOSHIBA I 53

CON

TRO

LS

LOCAL REMOTE CONTROLS

Type / DescriptionSingle price

excl. VAT (EUR)

Easy remote control: RBC-AS41E LCD display, temperature setting, mode selector switch, fan control, louver control, room temperature sensor,

up to 8 units controllable simultaneously, fault diagnosis system, filter warning light, DN-codes cannot be

moved

105,–

Standard remote control: RBC-AMT32E LCD display, temperature setting, mode selector switch, fan speed control, 168 hours on / off timer, louver

control, room temperature sensor, up to 8 units controllable simultaneously, fault diagnosis system, filter

warning light, DN-codes adjustable

95,–

Remote control with integrated weekly timer: RBC-AMS41E Same functions as remote control RBC-AMT32E but with an integrated weekly timer, in doing so

8 occasions per day can be programmed, DN-codes adjustable

110,–

Comfort remote control: RBC-AMS51E-ESWired remote control with weekly timer and multilingual menu navigation (D, E), modern design, backlight,

hot keys for easy operation, room temperature sensor integrated, DN-codes adjustable

145,–

Infrared remote control + receiver kit for the 4-way cassette(DI/S-DI series 4 or SMMS-i series 4): RBC-AX32U(W)-ELike RBC-AMT32E but wireless, not compatible with weekly timer; receiver kit can be installed easily on the

unit, address setting as well as the setting for the automatic restart function are not possible via the infrared

remote control

230,–

Infrared remote control and receiver for 2-way cassette: RBC-AX32UW(W)-EFunctions such as RBC-AMT32E but wireless, not compatible with weekly timer; receiver kit can be installed

easily on the unit; address setting as well as the setting for the automatic restart function not possible via

the infrared remote control

260,–

Infrared remote control + receiver kit for ceiling types and 1-way cassette (series SH): RBC-AX33CELike RBC-AMT32E but wireless, not compatible with weekly timer; receiver kit can be installed easily on the

unit; address setting as well as the setting for the automatic restart function not possible via the infrared

remote control

240,–

Infrared remote control with external receiver kit for 60x60 4-way cassette: TCB-AX32E2Infrared remote control kit suitable for all DI/S-DI and VRF indoor units; installation on the wall; address

setting as well as the setting for the automatic restart function not possible via the infrared remote control

320,–

54 I TOSHIBA

P R I C E L I S T – CONTROLSCO

NTR

OLS

CENTRAL REMOTE CONTROLS

Type / DescriptionSingle price

excl. VAT (EUR)

Compliant Manager: BMS-CM1280TLEReplaces central remote control, individual control of up to 128 units (2 x 64 indoor units TCC-Link Network

connections), Advanced Zone Configuration available (up to 64 programmable zones), 7-day timer can be

connected to weekly timer functions

1.900,–

7-day-timer: TCB-EXS21TLELCD display, 3 different on-/off-time settings (programs) per day programmable, each week-day (Mo-Su)

can be programmed individually with these 3 programs, holiday function, combination with

TCB-SC642TLE2 (central remote control) or alone directly to the TCC-link bus

390,–

On-/Off control for 16 indoor units: TCB-CC163TLE216 indoor units can be switched on or off individually or simultaneously within a VRF system

1.050,–

Smart Manager with data analysis and web interface: BMS-SM1280ETLECentral remote control for up to 128 indoor units; computer control via network, 7-day-timer and energy

accounting software (for electrical bill calculation the BMS-IFWH5E energy monitoring relay interface +

kWh-meter + computer with excel is necessary);

connected directly to TCC-link bus of the outdoor unit, data analysis, storing the data on a storage medium,

fault propagation with e-mail

2.350,–

Web based controller: BMS-WB2561PWEInternet server for up to 256 indoor units

Connection to TCC-link bus of the outdoor unit via one or several TCS-net relay interface BMS-IFLSV4E

5.400,–

Web based controller: BMS-WB01GTEInternet server for up to 2048 indoor units

Connection of up to 8 BMS-WB2561PWE web based controller via Ethernet

5.400,–

Touch Screen Controller with energy billing: BMS-CT5121E12,1 TFT multi-touch screen with a resolution of 1024 x 768 pixels; incl. energy billing option means

«Energy Monitoring Interface» ■ Individual control of up to 512 indoor units ■ Web connection ■ Presentation of floor plans ■ Grafik function ■ Error forwarding via email ■ Display of unit status, operating mode, room temperature, outdoor temperature, power demand ■ Daily, weekly and monthly time switch programmable ■ Temperature setting and Manual Mode limitations ■ Individual and group control ■ Energy accounting software (for electrical bill calculation the BMS-IFWH5E energy monitoring relay

interface + kWh-meter + computer with excel is necessary) ■ Energy saving options of indoor units and the outdoor unit ■ Failure diagnostics system

5.500,–

TOSHIBA I 55

CON

TRO

LS

BUILDING MANAGEMENT SYSTEMS

Type / DescriptionSingle price

excl. VAT (EUR)

TCS Net relay interface: BMS-IFLSV4EInterface between touch screen controller or BACnet server and TCC-link. For max. 64 indoor units or max. 16 systems

960,–

BACnet server: BMS-LSV9EAdapter for connection of TCC-link network to a BACnet-system

5.100,–

BACnet server software: BMS-STBN10ESoftware for BMS-LSV9E

2.600,–

Small BACnet interface: BMS-IFBN640TLERelay I / F (BMS-IFLSV4E) is not necessary; connection up to 64 indoor units; mounting on DIN rail possible; BTL certificate

1.650,–

LonWorks Gateway for TCC-link: TCB-IFLN642TLEfor controlling of up to 64 indoor units

1.600,–

Software „Interactive Intelligence II“: RBC-WP1-PEfor controlling of VRF units via computer

(optional LonWorks interface TCB-IFLN642TLE necessary)

6.900,–

ModBus inferface: TCB-IFMB641TLEAdapter for connecting TCC-link network to a modbus system

for controlling of up to 64 indoor units

2.000,–

Analogue interface: TCB-IFCB64OTLEfor controlling of up to 64 indoor units

2.100,–

General purpose interface: TCB-IFCG1TLE 2.100,–

Digital input/output relay interface: BMS-IFDD03E8 inputs / 4 outputs

1.200,–

Energy monitoring relay interface: BMS-IFWH5EEnergy billing module with daily and monthly billing option;

kWh-meter must be installed on site (max. 10 pulse per kWh) / for max. 8 kWh-meter

1.200,–

COOLMASTER - unit: COOLMASTER.netIntegration of HVAC systems with home automation & BMS option; Touch Screen display for system management & control

2.660,–

COOLMASTER - knx option: COOLMASTER.knxExtension board for direct KNX connection

590,–

COOLMASTER - License for 128 indoor units: COOLMASTER.licencefor the control of up to 128 indoor units

590,–

IntesisBox: TO-RC-KNX-1iKNX connection for one indoor unit (TCC-Link)

380,–

IntesisBox: TO-AC-KNX-16KNX connection for 16 indoor units (TCC-Link)

2.580,–

IntesisBox: TO-AC-KNX-64KNX connection for 64 indoor units (TCC-Link)

4.950,–

56 I TOSHIBA

P R I C E L I S T – CONTROLSCO

NTR

OLS

Control options

Special accessories RAV / VRF

Type / DescriptionSingle price

excl. VAT (EUR)

for indoor units

Analogue interface: RBC-FDP3-PEInterface to control the temperature, fan speed, mode, louver, on/off and lock of indoor unit through 0 – 10V signal

550,–

Fault, indication and remote on/off module: TCB-IFCB-4E2 Floating contacts for operation and fault indication;

Connections for external on/off

325,–

Window switch & on/off: TCB-IFCB5-PE Potential-free contact for on/off and window switch control

50,–

TCB-PX100-PEChassis for TCB-IFCB5-PE

35,–

Wireless temperature sensor: TCB-TC41LEChassis with external room temperature sensor

95,–

TCC-Link adapter: TCB-PCNT30TLE2 Adapter of DI & S-DI TCC-link to VRF TCC-link

115,–

TCB-PX30MUETerminal box for TCC-link adapter TCB-PCNT30TLE2

95,–

Redundancy box: TCB-ACREDU1-EFault, operational and switch box, wired ready for connection, integrated temperature sensor

1.550,–

Leak Detector: RBC-RD3-PE 660,–

Leak Detection system:

Leak Detection controller: TCB-LD1 340,–

Leak Detection sensor: TCB-LDS1 plastic 730,–

Leak Detection senosr: TCB-LDS2 steel 750,–

Leak Detection isolation valve: TCB-AW17861 12,7 mm 800,–

Leak Detection isolation valve: TCB-AW17862 15,9 mm 800,–

Leak Detection chassis: TCB-LDSBB1 plastic for Rigips 12,–

Leak Detection chassis: TCB-LDSBB2 metall for wall 12,–

for outdoor units

Application control kit for DI outdoor units series 4 + SDI outdoor units sizes 5: TCB-PCOS1E2 Inputs for reduction of capacity and sound, output for compressor „on“

240,–

CDU control for Super DI outdoor units series 4: TCB-KBOS2E (Sizes 8, 11, 14) and DI Big, inputs for reduction of capacity and sound, output for compressor „on“

40,–

Fault indication module*: TCB-PCIN4E Operating and fault message output

125,–

Antifreeze; remote on/off module*: TCB-PCMO4E Inputs for ext. on/off, priority cooling/heating, sound reduction and outdoor unit fan „on“

90,–

Module for energy limitation/load control*: TCB-PCDM4E Inputs for ext. on/off and reduction of capacity (6 stages)

115,–

TCB-IFGSM1E: GSM control interface 670,–

* for VRF outdoor units

Type Description Packaging unitPrice per unit

excl. VAT (EUR)

Connector with cable: Connection cable (50 cm) plus connector for the control of equipment on site

TCB-KBCN32VEE Connector with cable for CN32 1 pcs. 4,–

CN6O Connector with cable for CN60 1 pcs. 8,–

TCB-KBCN61HAE Connector with cable for CN61 1 pcs. 8,–

TCB-KBCN70OAE Connector with cable for CN70 1 pcs. 4,–

TCB-KBCN73DEE Connector with cable for CN73 1 pcs. 4,–

TCB-KBCN80EXE Connector with cable for CN80 1 pcs. 4,–

TOSHIBA I 57

CON

TRO

LS

TOSHIBA SERVICE PROGRAMS

Type Additional informationPrice per unit

excl. VAT (EUR)

TCB-DK01SS-E Dyna Doctor Hardware 1.500,–

Software for the Dyna Doc is available free for download:www.air-cond.com

■ Partner Login ■ Downloads ■ Software ■ Dyna Doctor

■ Computer software for the service technique

■ Display and record of data of the units: unit on/off, cooling or heating operation, PMV open level, temperature data, pressure level, compressor on/off, Check code consisting of: adapter box, cable for the unit, cable for the computer and CD-ROM

Model: AP-IR-WIFI-1Model name Single price excl. VAT (EUR)

AP-IR-WIFI-1Control module for remote control via smartphone (for IOS and Android), tablet and PCCompatible with all indoor units that are equipped with a standard infrared remote control

275,–

Model: TO-RC-WIFI-1Model name Single price excl. VAT (EUR)

TO-RC-WIFI-1Control module for remote control of RAV and VRF indoor units via smartphone (for IOS and Android), tablet and PC Connection via A / B bus

390,–

■ AirPatrol and Intesis Home are modern solutions to manage remotely your climate system using a simple smartphone (for IOS and Android), tablet or PC via Internet.

■ An external module which is either infrared-controlled or wired provides the connection between the air conditioning unit and the server.

■ The control is carried out via smartphone (for IOS and Android), tablet or computer using a website, which is working in the background and visible only through the app (for IOS and Android).

58 I TOSHIBA

P R I C E L I S T – ESTIAES

TIA

TypeCapacity (kW) Power consumption (kW) Efficiency Nominal water flow

rate (l/min) Dimensions

(H × W × D) (mm)Price (EUR)excl. VAT

❄ ❄ ❄

1-phase

HWS-804H-E(1) 8,00 6,00 1,79 1,94 4,46 3,10 22,90 890 × 900 × 320 2.520,–

HWS-1104H-E(1) 11,20 10,00 2,30 3,26 4,88 3,07 32,10 1340 × 900 × 320 3.000,–

HWS-1404H-E(1) 14,00 11,00 3,11 3,81 4,50 2,89 40,10 1340 × 900 × 320 3.300,–

3-phase

HWS-1104H8-E(1) 11,20 10,00 2,34 3,26 4,80 3,07 32,10 1340 × 900 × 320 3.220,–

HWS-1404H8-E(1) 14,00 11,00 3,16 3,81 4,44 2,89 40,10 1340 × 900 × 320 3.540,–

HWS-1604H8-E(1) 16,00 13,00 3,72 4,80 4,30 2,71 45,80 1340 × 900 × 320 4.050,–

Heating ❄ Cooling

ESTIA Series 4

Type Compatibility with outdoor units Electric backup heater Minimum waterflow rate (l/min)

Dimensions(H × W × D) (mm)

Price (EUR)excl. VAT

HWS-804XWHM3-E(1)

HWS-804H-E

230 V; 3 kW 13,0 925 × 525 × 355 3.600,–

HWS-804XWHT6-E(1) 2 × 230 V; 6 kW 13,0 925 × 525 × 355 3.650,–

HWS-804XWHT9-E(1) 3 × 230 V; 9 kW 13,0 925 × 525 × 355 3.750,–

HWS-1404XWHM3-E(1)HWS-1104, 1404H-E

HWS-1104, 1404, 1604H8-E

230 V; 3 kW 17,5 925 × 525 × 355 4.350,–

HWS-1404XWHT6-E(1) 2 × 230 V; 6 kW 17,5 925 × 525 × 355 4.450,–

HWS-1404XWHT9-E(1) 3 × 230 V; 9 kW 17,5 925 × 525 × 355 4.550,–

Outdoor unit

Hydro Box

■ Extremely high levels of efficiency - COP up to 4,88

■ Piping length up to 30 m

■ A-class water pump (EEI ≤ 0,23)

■ Leaving water temperature: Heating: 20 - 55°C, cooling: 7 - 30°C

■ 2 temperature zones possible

■ Integrated remote control

TOSHIBA I 59

ESTI

A

ESTIA HI POWER

TypeCapacity (kW) Power consumption (kW) Efficiency Nominal water flow

rate (l/min) Dimensions

(H × W × D) (mm)Price (EUR)excl. VAT

❄ ❄ ❄

1-phase

HWS-P804HR-E(1) 8,00 6,00 1,68 1,64 4,76 3,66 22,90 1340 × 900 × 320 3.400,–

HWS-P1104HR-E(1) 11,20 10,00 2,30 3,33 4,88 3,00 32,10 1340 × 900 × 320 3.700,–

Heating ❄ Cooling

PERFECT FOR RENOVATION WITHOUT CHANGING RADIATORS!

■ EHPA certified

■ Leaving water temperature up to 60 °C

■ Operation range down to outdoor temperatures of -25 °C

■ Full rated capacity down to -15 °C

■ High flexibility

■ Top efficiency & COP

■ 2-zone temperature control

Outdoor unit

Hydro Box

Type Compatibility with outdoor units Electric backup heater Minimal water flowrate (l/min)

Dimensions(H × W × D) (mm)

Price (EUR)excl. VAT

HWS-P804XWHM3-E(1)

HWS-P804HR-E

230 V; 3 kW 13,0 925 × 525 × 355 3.600,–

HWS-P804XWHT6-E(1) 2 × 230 V; 6 kW 13,0 925 × 525 × 355 3.650,–

HWS-P804XWHT9-E(1) 3 × 230 V; 9 kW 13,0 925 × 525 × 355 3.750,–

HWS-P1104XWHM3-E(1)

HWS-P1104HR-E

230 V; 3 kW 17,5 925 × 525 × 355 4.350,–

HWS-P1104XWHT6-E(1) 2 × 230 V; 6 kW 17,5 925 × 525 × 355 4.450,–

HWS-P1104XWHT9-E(1) 3 × 230 V; 9 kW 17,5 925 × 525 × 355 4.550,–

60 I TOSHIBA

P R I C E L I S T – ESTIAES

TIA

Estia Hot water tank

Estia Accessories

■ Stainless steel – isolated

■ Electric backup heater with 2,75 kW (for legionella control and water heating > 43 °C)

■ Temperature sensor included

■ Safety thermo element

TypeContent

literMax. watertemperature

Electric heater (kW)

CurrentHeight(mm)

Diameter(mm)

MaterialPrice (EUR)excl. VAT

HWS-1501CSHM3-E 150 75 2,75

1-phase

230 V

1.090 550

Stainless steel

1.290,–

HWS-2101CSHM3-E 210 75 2,75 1.474 550 1.520,–

HWS-3001CSHM3-E 300 75 2,75 2.040 550 1.790,–

Type DescriptionPrice (EUR)excl. VAT

TCB-PCMO3E

Interface for external inputs (voltage free contacts): ■ Input for heating requirement (room thermostat)

■ Input for cooling requirement (room thermostat)

Alternatively, the two inputs can be used as follows: ■ Input for external emergency stop switch-off

■ Input for hot water demand to the tank

100,–

TCB-PCIN3E

Interface for external inputs (voltage free contacts): ■ Output for activating external heating system

■ Output for alarm signals

Alternatively, the two outputs can be used as follows: ■ Defrost signal output

■ Operation signal output

135,–

Sensor 95612037 Temperature sensor for on-site hot water tank 50,–

VK320M0AIRCO01* Replacement Flow Switch 65,–

HWS-AMS11E Remote control 170,–

* Spare part, no discount

Measuring for Toshiba air-to-water heat pump

Heating: Outdoor temperature 7 °C DB, 6 °C WB, 35 °C Leaving water temperature, ΔT = 5 °CCooling: Outdoor temperature 35 °C DB, 18 °C Leaving water temperature, ΔT = 5 °CRefrigerant pipes: 7,5 m length and no height difference between indoor and outdoor unitSound pressure level: measured in 1 m distance to outdoor unit according to „JIS“ standard

TOSHIBA I 61

ESTI

A

62 I TOSHIBA

P R I C E L I S T – ADDITIONAL INFORMATIONA

DD

ITIO

NA

LIN

FOR

MAT

ION

TypeCapacity (kW) Length of pipes (m) Dimensions of pipes (inches) Refrigerant

weight (kg)

Additional charge (g/m)

❄ / min./max. Height difference pre-charged Gas side Liquid side

RAS Inverter

RAS-107SAV-E6 2,50 / 3,20 2/15 8 15 3/8 1/4 0,63 -

RAS-137SAV-E6 3,15 / 3,20 2/15 8 15 3/8 1/4 0,63 -

RAS-167SAV-E5 4,40 / 5,20 2/20 10 15 1/2 1/4 1,05 20

RAS-10BAV-E 2,50 / 3,20 2/15 12 15 3/8 1/4 0,43 -

RAS-10BAVG-E 2,50 / 3,20 2/15 12 15 3/8 1/4 0,43 -

RAS-13BAV-E 3,10 / 3,70 2/15 12 15 3/8 1/4 0,43 -

RAS-13BAVG-E 3,10 / 3,60 2/15 12 15 3/8 1/4 0,43 -

RAS-16BAV-E 4,40 / 5,20 2/20 10 15 3/8 1/4 0,80 20

RAS-16BAVG-E 4,60 / 5,40 2/20 10 15 3/8 1/4 0,80 20

RAS-10N3AV2-E1 2,50 / 3,20 2/20 10 15 3/8 1/4 0,80 20

RAS-13N3AV2-E1 3,50 / 4,20 2/20 10 15 3/8 1/4 0,80 20

RAS-16N3AV2-E 4,50 / 5,50 2/20 10 15 1/2 1/4 1,10 20

RAS-18N3AV2-E 5,00 / 5,80 2/20 10 15 1/2 1/4 1,40 20

RAS-22N3AV2-E 6,00 / 7,00 2/20 10 15 1/2 1/4 1,40 20

RAS-10G2AVP-E 2,50 / 3,20 2/25 10 15 3/8 1/4 1,05 20

RAS-13G2AVP-E 3,50 / 4,00 2/25 10 15 3/8 1/4 1,05 20

RAS-16G2AVP-E 4,50/ 5,50 2/25 10 15 1/2 1/4 1,05 20

RAS Multi Inverter

RAS-2M14S3AV-E 4,00 / 4,40 3/30 10 30 3/8 1/4 1,32 20

RAS-2M18S3AV-E 5,20 / 5,60 3/30 10 30 3/8 1/4 1,32 20

RAS-3M18S3AV-E 5,20 /6,80 3/50 10 50 3/8 * - 1/2 ** 1/4 1,50 20

RAS-3M26S3AV-E 7,50 / 9,00 3/70 15 40 3/8 * - 1/2 ** 1/4 2,40 20

RAS-4M27S3AV-E 8,00 / 9,00 3/70 15 40 3/8 *- 1/2 ** 1/4 2,40 20

RAS-5M34S3AV-E 10,00 / 12,00 3/80 15 40 3/8 * - 1/2 ** 1/4 2,99 20

Digital Inverter

RAV-SM304ATP-E 2,50 / 3,40 2/20 10 15 3/8 1/4 0,80 20

RAV-SM404ATP-E 3,60 / 4,00 2/20 10 15 1/2 1/4 1,40 20

RAV-SM564ATP-E 5,00 / 5,30 5/30 30 20 1/2 1/4 1,10 40

RAV-SM804ATP-E 6,70 / 7,70 5/30 30 20 5/8 3/8 1,70 40

RAV-SM1104ATP-E 10,00 / 11,20 5/50 30 30 5/8 3/8 2,80 40

RAV-SM1404ATP-E 12,10 / 12,80 5/50 30 30 5/8 3/8 2,80 40

RAV-SM1603AT-E 14,00 / 16,00 5/50 30 30 5/8 3/8 3,10 40

DI BIG

RAV-SM2244AT8-E 20,00 / 22,40 7,5/70 30 30 1 1/8 1/2 5,90 40

RAV-SM2804AT8-E 23,00 / 27,00 7,5/70 30 30 1 1/8 1/2 5,90 40

S-DI

RAV-SP564ATP-E 5,00 / 5,60 5/50 30 20 1/2 1/4 1,40 40

RAV-SP804ATP-E 7,10 / 8,00 5/50 30 30 5/8 3/8 2,10 40

RAV-SP1104AT-E 10,00 / 11,20 5/75 30 30 5/8 3/8 3,10 40

RAV-SP1404AT-E 12,50 / 14,00 5/75 30 30 5/8 3/8 3,10 40

S-DI 3-phase

RAV-SP1104AT8-E 10,00 / 11,20 3/75 30 30 5/8 3/8 3,10 40

RAV-SP1404AT8-E 12,50 / 14,00 3/75 30 30 5/8 3/8 3,10 40

RAV-SP1604AT8-E 14,00 / 16,00 3/75 30 30 5/8 3/8 3,10 40

❄ Cooling Heating * with connection of RAS-M / B10 or RAS-M / B13 indoor units type ** with connection of RAS-M / B16 or B18 RAS / B22 indoor unit type

ADDITIONAL INFORMATION

TOSHIBA I 63

AD

DIT

ION

AL

INFO

RM

ATIO

N

ADDITIONAL INFORMATION

TypeCapacity (kW) Power supply Electronical wire

indoor / outdoor (mm²)

Remote controlIR / (mm²)

❄ / Power supply Fuse (tr.) ( V / A )

RAS Inverter

RAS-107SAV-E6 2,50 / 3,20 Outdoor unit 220-240 / 10 4 × 1,5 IR

RAS-137SAV-E6 3,15 / 3,20 Outdoor unit 220-240 / 10 4 × 1,5 IR

RAS-167SAV-E5 4,40 / 5,20 Outdoor unit 220-240 / 16 4 × 1,5 IR

RAS-10BAV-E 2,50 / 3,20 Outdoor or indoor unit 220-240 / 10 4 × 1,5 IR

RAS-10BAVG-E 2,50 / 3,20 Outdoor or indoor unit 220-240 / 10 4 × 1,5 IR

RAS-13BAV-E 3,10 / 3,70 Outdoor or indoor unit 220-240 / 10 4 × 1,5 IR

RAS-13BAVG-E 3,10 / 3,60 Outdoor or indoor unit 220-240 / 10 4 × 1,5 IR

RAS-16BAV-E 4,40 / 5,20 Outdoor or indoor unit 220-240 / 16 4 × 1,5 IR

RAS-16BAVG-E 4,60 / 5,40 Outdoor or indoor unit 220-240 / 16 4 × 1,5 IR

RAS-10N3AV2-E1 2,50 / 3,20 Outdoor unit 220-240 / 10 4 × 1,5 IR

RAS-13N3AV2-E1 3,50 / 4,20 Outdoor unit 220-240 / 10 4 × 1,5 IR

RAS-16N3AV2-E 4,50 / 5,50 Outdoor unit 220-240 / 16 4 × 1,5 IR

RAS-18N3AV2-E 5,00 / 5,80 Outdoor unit 220-240 / 16 4 × 1,5 IR

RAS-22N3AV2-E 6,00 / 7,00 Outdoor unit 220-240 / 16 4 × 1,5 IR

RAS-10G2AVP-E 2,50 / 3,20 Outdoor or indoor unit 220-240 / 10 4 × 1,5 IR

RAS-13G2AVP-E 3,50 / 4,00 Outdoor or indoor unit 220-240 / 10 4 × 1,5 IR

RAS-16G2AVP-E 4,50 / 5,50 Outdoor or indoor unit 220-240 / 16 4 × 1,5 IR

RAS Multi Inverter

RAS-2M14S3AV-E 4,00 / 4,40 Outdoor unit 220-240 / 16 je 4 × 1,5 IR

RAS-2M18S3AV-E 5,20 / 5,60 Outdoor unit 220-240 / 16 je 4 × 1,5 IR

RAS-3M18S3AV-E 5,20 / 6,80 Outdoor unit 220-240 / 16 je 4 × 1,5 IR

RAS-3M26S3AV-E 7,50 / 9,00 Outdoor unit 220-240 / 16 je 4 × 1,5 IR

RAS-4M27S3AV-E 8,00 / 9,00 Outdoor unit 220-240 / 20 je 4 × 1,5 IR

RAS-5M34S3AV-E 10,00 / 12,00 Outdoor unit 220-240 / 20 je 4 × 1,5 IR

Digital Inverter

RAV-SM304ATP-E 2,50 / 3,40 Outdoor unit 220-240 / 16 4 × 1,5 2 x 0,75 / IR

RAV-SM404ATP-E 3,60 / 4,00 Outdoor unit 220-240 / 16 4 × 1,5 2 x 0,75 / IR

RAV-SM564ATP-E 5,00 / 5,30 Outdoor unit 220-240 / 13 4 × 1,5 2 x 0,75 / IR

RAV-SM804ATP-E 6,70 / 7,70 Outdoor unit 220-240 / 16 4 × 1,5 2 x 0,75 / IR

RAV-SM1104ATP-E 10,00 / 11,20 Outdoor unit 220-240 / 20 4 × 1,5 2 x 0,75 / IR

RAV-SM1404ATP-E 12,10 / 12,80 Outdoor unit 220-240 / 25 4 × 1,5 2 x 0,75 / IR

RAV-SM1603AT-E 14,00 / 16,00 Outdoor unit 220-240 / 32 4 × 1,5 2 x 0,75 / IR

DI BIG

RAV-SM2244AT8-E 20,00 / 22,40 Outdoor unit 380-415 / 3 x 20 4 × 1,5 2 x 0,75 / IR

RAV-SM2804AT8-E 23,00 / 27,00 Outdoor unit 380-415 / 3 x 25 4 × 1,5 2 x 0,75 / IR

S-DI

RAV-SP564ATP-E 5,00 / 5,60 Outdoor unit 220-240 / 13 4 × 1,5 2 x 0,75 / IR

RAV-SP804ATP-E 7,10 / 8,00 Outdoor unit 220-240 / 16 4 × 1,5 2 x 0,75 / IR

RAV-SP1104AT-E 10,00 / 11,20 Outdoor unit 220-240 / 20 4 × 1,5 2 x 0,75 / IR

RAV-SP1404AT-E 12,50 / 14,00 Outdoor unit 220-240 / 20 4 × 1,5 2 x 0,75 / IR

S-DI 3-phase

RAV-SP1104AT8-E 10,00 / 11,20 Outdoor unit 380-415 / 3 x 20 4 × 1,5 2 x 0,75 / IR

RAV-SP1404AT8-E 12,50 / 14,00 Outdoor unit 380-415 / 3 x 20 4 × 1,5 2 x 0,75 / IR

RAV-SP1604AT8-E 14,00 / 16,00 Outdoor unit 380-415 / 3 x 20 4 × 1,5 2 x 0,75 / IR

❄ Cooling Heating

64 I TOSHIBA

P R I C E L I S T – ADDITIONAL INFORMATIONA

DD

ITIO

NA

LIN

FOR

MAT

ION

ModelsOfficial outdoor temperature range limits

(acc. to TOSHIBA specification)Low ambient operation

Automatic restart functionafter power failure

RAS Inverter Single AvAnt

RAS-107SAV-E6RAS-137SAV-E6RAS-167SAV-E5

■ Outdoor temperature range Cooling mode: -10°C till +46°C

■ Outdoor temperature Heating mode: -15°C till +24°C

■ Not suitable for cooling mode at low outside-temperatures as the unit will be switched off at an outside temperature of approx. -10°C! (No condenser pressure control)

■ Cooling possible under certain conditions to -10°C

Included

(not activated by the factory)

To activate: ■ Press the „Reset“ button at the indoor unit

for 3 seconds

RAS Inverter Single MIRAI

RAS-10BAV-ERAS-10BAVG-ERAS-13BAV-ERAS-13BAVG-ERAS-16BAV-ERAS-16BAVG-E

■ Outdoor temperature range Cooling mode: -15°C till +46°C

■ Outdoor temperature Heating mode: -15°C till +24°C

■ Not suitable for cooling mode at low outside-temperatures as the unit will be switched off at an outside temperature of approx. -15°C! (keine Kondensatordruckregelung)

■ Cooling possible under certain conditions to -15°C

Included

(not activated by the factory)

To activate: ■ Press the „Reset“ button at the indoor unit

for 3 seconds

RAS Inverter Single Suzumi Plus or Console

RAS-10N3AV2-E1RAS-13N3AV2-E1RAS-16N3AV2-ERAS-18N3AV2-ERAS-22N3AV2-E

■ Outdoor temperature range Cooling mode: -10°C till +46°C

■ Outdoor temperature Heating mode: -15°C till +24°C

■ Not suitable for cooling mode at low outside-temperatures as the unit will be switched off at an outside temperature of approx. -10°C!

■ Cooling possible until -10°C

Included

(not activated by the factory)

To activate: ■ Press the „Reset“ button at the indoor unit

for 3 seconds

RAS Single Super Daiseikai 8

RAS-10G2AVP-E RAS-13G2AVP-ERAS-16G2AVP-E

■ Outdoor temperature range Cooling mode: -10°C till +46°C

■ Outdoor temperature Heating mode: -15°C till +24°C

■ Not suitable for cooling mode at low outside-temperatures as the unit will be switched off at an outside temperature of approx. -10°C!

■ Cooling possible until -10°C

Included

(not activated by the factory)

To activate: ■ Press the „Reset“ button at the indoor unit

for 3 seconds

Information for the AIR CONDITIONING AT LOW OUTSIDE TEMPERATURES

TOSHIBA I 65

AD

DIT

ION

AL

INFO

RM

ATIO

N

ModelsOfficial outdoor temperature range limits

(acc. to TOSHIBA specification)Low ambient operation

Automatic restart functionafter power failure

RAS Inverter Multi

RAS-2M14S3AV-ERAS-2M18S3AV-ERAS-3M18S3AV-E

■ Outdoor temperature range Cooling mode: -10°C till +46°C

■ Outdoor temperature Heating mode: -20°C till +24°C

Included

(not activated by the factory)

To activate: ■ Press the „Reset“ button at the indoor unit

for 3 seconds

RAS-3M26S3AV-ERAS-4M27S3AV-ERAS-5M34S3AV-E

■ Outdoor temperature range Cooling mode: -10°C till +46°C

■ Outdoor temperature Heating mode: -15°C till +24°C

Digital Inverter & Super Digital Inverter & DI BIG

RAV-SM304ATP-ERAV-SM404ATP-E

■ Outdoor temperature range Cooling mode: -15°C till +46°C

■ Outdoor temperature Heating mode: -15°C till +24°C

Perfect for cooling operation at low outdoor temperature, as:

■ Low ambient kit is included

■ Oil heater is included

■ Cooling is also possible with an outside temperature below -15 °C and unit doesn‘t switch off!

■ Take care for wind protection!

■ For the room inside air humidification might be necessary!

Included

(not activated by the factory)

■ To activate: Hi-wall, cassette, duct, ceiling:

Change in the DN Code menu of the remote

control the value of line 28 from «0» to «1»

RAV-SM564ATP-ERAV-SM804ATP-ERAV-SM1104ATP-E

■ Outdoor temperature range Cooling mode: -15°C till +46°C

■ Outdoor temperature Heating mode: -15°C till +15°C

RAV-SM1404ATP-E ■ Outdoor temperature range Cooling mode: -15°C till +46°C

■ Outdoor temperature Heating mode: -20°C till +15°C

RAV-SM1603AT-E ■ Outdoor temperature range Cooling mode: -15°C till +43°C

■ Outdoor temperature Heating mode: -15°C till +15°C

RAV-SP564ATP-ERAV-SP804ATP-ERAV-SP1104AT-ERAV-SP1404AT-E

■ Outdoor temperature range Cooling mode: -15°C till +43°C

■ Outdoor temperature Heating mode: -20°C till +15°C

RAV-SM2244AT8-ERAV-SM2804AT8-E

■ Outdoor temperature range Cooling mode: -15°C till +46°C

■ Outdoor temperature Heating mode: -20°C till +15°C

Information for the AIR CONDITIONING AT LOW OUTSIDE TEMPERATURES

66 I TOSHIBA

P R I C E L I S T – ADDITIONAL INFORMATIONA

DD

ITIO

NA

LIN

FOR

MAT

ION

Current consumption + protection

Outdoor unitCurrent

consumptionmaximum (A)

Currentconsumptionnominal (A)

❄ /

Powerconsumptionnominal (kW)

Recommendedprotection

(A)Supply voltage

*Recommendedcable type

power supplyH07RN-F*G**²

Communication-cable

H07RN-F*G**²

RESIDENTIAL

AvAnt

RAS-107SAV-E6 8 3,67/3,95 0,800 10 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

RAS-137SAV-E6 8 5,16/4,46 1,065 10 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

RAS-167SAV-E5 10 7,13/6,91 1,530 13 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

MIRAI

RAS-10BAV-E 0,85 10 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

RAS-10BAVG-E 0,85 10 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

RAS-13BAV-E 1,15 10 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

RAS-13BAVG-E 1,15 10 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

RAS-16BAV-E 1,56 16 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

RAS-16BAVG-E 1,53 16 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

Suzumi Plus + Console

RAS-10N3AV2-E1 8,5 2,81/3,43 0,710 10 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

RAS-13N3AV2-E1 9,1 4,57/4,93 1,040 10 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

RAS-16N3AV2-E 11 6,33/6,86 1,458 16 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

RAS-18N3AV2-E 10 6,35/6,98 1,520 16 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

RAS-22N3AV2-E 13,5 9,31/9,56 2,000 16 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

Super Daiseikai 8

RAS-10G2AVP-E 11 2,58/3,10 0,580 10 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

RAS-13G2AVP-E 11 4,03/3,84 0,800 10 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

RAS-16G2AVP-E 11 6,24/6,41 1,370 16 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

Multi split

RAS-2M14S3AV-E 12,6 3,87/3,96 0,83 16 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

RAS-2M18S3AV-E 12,6 6,15/5,48 1,34 16 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

RAS-3M18S3AV-E 13,1 5,39/7,22 1,17 16 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

RAS-3M26S3AV-E 16,1 9,15/10,07 2,0 16 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

RAS-4M27S3AV-E 16,4 10,46/8,82 2,29 20 220-240V/1Ph+N/50Hz 3G2,5 4G1,5

RAS-5M34S3AV-E 19,5 13,65/12,97 2,98 20 220-240V/1Ph+N/50Hz 3G2,5 4G1,5

LIGHT COMMERCIAL

Digital Inverter

RAV-SM304ATP-E 7,85 0,85 13 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

RAV-SM404ATP-E 9,15 1,12 13 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

RAV-SM564ATP-E 12,3 7,31/6,37 1,56 13 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

RAV-SM804ATP-E 14,3 10,40/9,98 2,22 16 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

RAV-SM1104ATP-E 20,8 14,60/14,17 3,02 20 220-240V/1Ph+N/50Hz 3G2,5 4G1,5

RAV-SM1404ATP-E 22,8 20,74/16,44 3,57 25 220-240V/1Ph+N/50Hz 3G2,5 4G1,5

RAV-SM1603AT-E 29,7 21,48/21,20 4,49 25 220-240V/1Ph+N/50Hz 3G2,5 4G1,5

Super Digital Inverter

RAV-SP564ATP-E 15,0 6,82/5,61 1,47 16 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

RAV-SP804ATP-E 20,8 8,72/8,95 1,86 16 220-240V/1Ph+N/50Hz 3G1,5 4G1,5

RAV-SP1104AT-E 22,8 10,36/10,96 2,34 20 220-240V/1Ph+N/50Hz 3G2,5 4G1,5

RAV-SP1104AT8-E 16,4 4,45/4,52 2,42 16 380-415V/3Ph+N/50Hz 3G1,5 4G1,5

RAV-SP1404AT-E 22,8 14,66/14,89 3,21 20 220-240V/1Ph+N/50Hz 3G2,5 4G1,5

RAV-SP1404AT8-E 16,4 6,03/5,97 3,46 16 380-415V/3Ph+N/50Hz 3G1,5 4G1,5

RAV-SP1604AT8-E 16,4 7,55/7,26 4,49 16 380-415V/3Ph+N/50Hz 3G1,5 4G1,5

❄ Cooling Heating

TOSHIBA I 67

AD

DIT

ION

AL

INFO

RM

ATIO

N

Outdoor unitCurrent

consumptionmaximum (A)

Currentconsumptionnominal (A)

❄ /

Powerconsumptionnominal (kW)

Recommendedprotection

(A)Supply voltage

*Recommendedcable type

power supplyH07RN-F*G**²

Communication-cable

H07RN-F*G**²

Digital Inverter Big

RAV-SM2244AT8-E 18,0 10,09/9,41 6,24 20 380-415V/3Ph+N/50Hz 5G2,5 4G1,5

RAV-SM2804AT8-E 22,0 13,24/12,09 8,19 25 380-415V/3Ph+N/50Hz 5G2,5 4G1,5

ESTIA

HWS-804H-E(1) 19,2 8,50/7,97 1,88 20 220-240V/1Ph/50Hz 3G2,5 4G1,5

HWS-1104H-E(1) 22,8 14,71/10,08 3,17 20 220-240V/1Ph/50Hz 3G2,5 4G1,5

HWS-1404H-E(1) 22,8 17,19/13,74 3,72 20 220-240V/1Ph/50Hz 3G2,5 4G1,5

HWS-1104H8-E(1) 14,6 5,08/3,73 3,17 3x16 380-415V/3Ph+N/50Hz 3G1,5 4G1,5

HWS-1404H8-E(1) 14,6 5,71/5,01 3,72 3x16 380-415V/3Ph+N/50Hz 3G1,5 4G1,5

HWS-1604H8-E(1) 14,6 7,51/5,94 4,71 3x16 380-415V/3Ph+N/50Hz 3G1,5 4G1,5

HI-Power

HWS-P804HR-E(1) 19,2 7,39/7,57 1,94 20 220-240V/1Ph/50Hz 3G2,5 4G1,5

HWS-P1104HR-E(1) 22,8 14,99/10,33 3,26 25 220-240V/1Ph/50Hz 3G2,5 4G1,5

COMMERCIAL

Mini-SMMS-i (1-phase) BUS cable:

MCY-MAP0401HT 25 13,8/13,1 2,820 20 220-240V/1Ph/50Hz 3G2,5 **

MCY-MAP0501HT 28 16,8/16,1 3,470 20 220-240V/1Ph/50Hz 3G2,5 **

MCY-MAP0601HT 31 22,4/23,2 4,630 25 220-240V/1Ph/50Hz 3G4,0 **

Mini-SMMS-e (3-phase) BUS cable:

MCY-MHP0404HS8-E 12,5 4,5/4,2 2,82 3x16 380-415V/3Ph+N/50Hz 5G1,5 **

MCY-MHP0504HS8-E 12,5 5,4/5,8 3,47 3x16 380-415V/3Ph+N/50Hz 5G1,5 **

MCY-MHP0604HS8-E 12,5 6,7/6,6 4,25 3x16 380-415V/3Ph+N/50Hz 5G1,5 **

SMMS-i

MMY-MAP0804HT8P-E 23,5 8,5/8,8 5,53 3x20 380-415V/3Ph+N/50Hz 5G2,5 **

MMY-MAP1004HT8P-E 25,5 11,4/11,8 7,50 3x20 380-415V/3Ph+N/50Hz 5G2,5 **

MMY-MAP1204HT8P-E 28,5 14,7/16,0 10,20 3x25 380-415V/3Ph+N/50Hz 5G4,0 **

MMY-MAP1404HT8P-E 33,2 17,7/17,6 11,50 3x25 380-415V/3Ph+N/50Hz 5G4,0 **

MMY-MAP1604HT8P-E 36,5 20,8/22,0 13,70 3x32 380-415V/3Ph+N/50Hz 5G6,0 **

SMMS-e

MMY-MAP0806HT8P-E 20,5 8,79/8,77 5,54 3x20 380-415V/3Ph+N/50Hz 5G2,5 **

MMY-MAP1006HT8P-E 21,5 12,1/11,6 7,69 3x20 380-415V/3Ph+N/50Hz 5G2,5 **

MMY-MAP1206HT8P-E 26,1 15,5/15,0 10,0 3x25 380-415V/3Ph+N/50Hz 5G4,0 **

MMY-MAP1406HT8P-E 31,0 19,5/17,8 12,33 3x32 380-415V/3Ph+N/50Hz 5G6,0 **

MMY-MAP1606HT8P-E 35,8 22,4/20,2 14,3 3x32 380-415V/3Ph+N/50Hz 5G6,0 **

MMY-MAP1806HT8P-E 40,6 22,9/22,1 14,6 3x40 380-415V/3Ph+N/50Hz 5G6,0 **

MMY-MAP2006HT8P-E 44,9 26,8/26,1 17,3 3x40 380-415V/3Ph+N/50Hz 5G6,0 **

MMY-MAP2206HT8P-E 49,3 35,6/26,5 23,2 3x50 380-415V/3Ph+N/50Hz 5G10,0 **

SHRM-i

MMY-MAP0804FT8-E 24,5 8,3/9,1 5,68 3x20 380-415V/3Ph+N/50Hz 5G2,5 **

MMY-MAP1004FT8-E 27,1 11,4/12,0 7,50 3x20 380-415V/3Ph+N/50Hz 5G2,5 **

MMY-MAP1204FT8-E 31,2 13,4/14,5 9,05 3x25 380-415V/3Ph+N/50Hz 5G4,0 **

MMY-MAP1404FT8-E 36,4 17,8/19,9 12,70 3x32 380-415V/3Ph+N/50Hz 5G6,0 **

*The correct calculation of cable cross-section is the responsibility of the executive electric installation company

**2-wire flexible / shielded <500m= 0,75mm²; >500m= 1,5mm²

68 I TOSHIBA

P R I C E L I S T – ADDITIONAL INFORMATIONA

DD

ITIO

NA

LIN

FOR

MAT

ION

Sound power / Sound pressure

Outdoor unitSound power: dB(A) Sound pressure: dB(A)

Noise reduction not possible dB(A)

❄ / ❄ / ❄ /

RESIDENTIAL

AvAnt

RAS-107SAV-E6 63/65 48/50 ---

RAS-137SAV-E6 63/65 48/50 ---

RAS-167SAV-E5 64/65 49/50 ---

MIRAI

RAS-10BAV-E 63/65 48/50 ---

RAS-10BAVG-E 63/65 48/50 ---

RAS-13BAV-E 63/65 48/50 ---

RAS-13BAVG-E 63/65 48/50 ---

RAS-16BAV-E 64/65 49/50 ---

RAS-16BAVG-E 64/65 49/50 ---

Suzumi Plus + Console

RAS-10N3AV2-E1 61/62 46/47 ---

RAS-13N3AV2-E1 63/65 48/50 ---

RAS-16N3AV2-E 64/65 49/50 ---

RAS-18N3AV2-E 64/65 49/50 ---

RAS-22N3AV2-E 68/67 49/50 ---

Super Daiseikai 8

RAS-10G2AVP-E 61/62 46/47 ---

RAS-13G2AVP-E 63/64 48/49 ---

RAS-16G2AVP-E 64/65 49/50 ---

Multi split

RAS-2M14S3AV-E 58/59 45/46 ---

RAS-2M18S3AV-E 60/63 47/50 ---

RAS-3M18S3AV-E 60/63 47/50 ---

RAS-3M26S3AV-E 63/64 48/49 ---

RAS-4M27S3AV-E 63/64 48/49 ---

RAS-5M34S3AV-E 66/68 52/55 ---

Outdoor unitSound power: dB(A) Sound pressure: dB(A)

Noise reduction with accessories connector dB(A)

❄ / ❄ / ❄ /

LIGHT COMMERCIAL

Digital Inverter TCB-PCOS1E2

RAV-SM304ATP-E 61/62 46/47 ---

RAV-SM404ATP-E 64/65 49/50 ---

RAV-SM564ATP-E 63/65 46/48 41/45

RAV-SM804ATP-E 65/69 48/52 43/48

RAV-SM1104ATP-E 70/71 53/54 46/50

RAV-SM1404ATP-E 70/71 54/55 49/50

RAV-SM1603AT-E 68/70 51/53 46/48

TOSHIBA I 69

AD

DIT

ION

AL

INFO

RM

ATIO

N

Outdoor unitSound power: dB(A) Sound pressure: dB(A)

Noise reduction with accessories connector dB(A)

❄ / ❄ / ❄ /

Super Digital Inverter TCB-PCOS1E2

RAV-SP564ATP-E 63/64 47/48 42/43

TCB-KBOS1E

RAV-SP804ATP-E 64/65 48/49 43/44

RAV-SP1104AT-E 66/67 49/50 44/45

RAV-SP1104AT8-E 66/67 49/50 44/45

RAV-SP1404AT-E 68/69 51/52 46/47

RAV-SP1404AT8-E 68/69 51/52 46/47

RAV-SP1604AT8-E 68/70 51/53 46/48

SDI Big TCB-KBOS1E

RAV-SM2244AT8-E 72/74 56/57 45/45

RAV-SM2804AT8-E 74/75 57/58 45/45

Outdoor unitSound power: dB(A) Sound pressure: dB(A)

Noise reduction with accessories board dB(A)

❄ / ❄ / ❄ /

COMMERCIAL

Mini-SMMS-i TCB-PCMO4E

MCY-MAP0401HT 49/50 46/48

MCY-MAP0501HT 50/52 46/48

MCY-MAP0601HT 51/53 47/49

Mini-SMMS-e

MCY-MHP0404HS8-E 66/67 49/52 46/48

MCY-MHP0504HS8-E 68/69 50/53 46/48

MCY-MHP0604HS8-E 68/70 51/54 47/49

SMMS-i TCB-PCMO4E

MMY-MAP0804HT8P-E 77/78 55/56 50/50

MMY-MAP1004HT8P-E 78/79 57/58 50/50

MMY-MAP1204HT8P-E 82/83 59/61 50/50

MMY-MAP1404HT8P-E 82/83 60/62 53/53

MMY-MAP1604HT8P-E 83/84 61/63 53/53

SMMS-e TCB-PCMO4E

MMY-MAP0806HT8P-E 74/74 55/56 54/54

MMY-MAP1006HT8P-E 74/74 57/58 54/54

MMY-MAP1206HT8P-E 80/82 59/61 54/54

MMY-MAP1406HT8P-E 80/82 60/62 53/53

MMY-MAP1606HT8P-E 81/83 62/64 53/53

MMY-MAP1806HT8P-E 81/83 60/61 50/50

MMY-MAP2006HT8P-E 82/84 61/62 50/50

MMY-MAP2206HT8P-E 83/84 61/62 50/50

SHRM-i TCB-PCMO4E

MMY-MAP0804FT8-E 77/79 55/57 50/50

MMY-MAP1004FT8-E 78/80 57/59 50/50

MMY-MAP1204FT8-E 81/83 60/62 53/53

MMY-MAP1404FT8-E 82/84 62/64 53/53

❄ Cooling Heating

70 I TOSHIBA

P R I C E L I S T – ADDITIONAL INFORMATIONA

DD

ITIO

NA

LIN

FOR

MAT

ION

VRF performance tables SMMS-e

ModelCapacity

MMY- MAP0806HT8P-E MAP1006HT8P-E MAP1206HT8P-E MAP1406HT8P-E MAP1606HT8P-E MAP1806HT8P-E MAP2006HT8P-E MAP2206HT8P-E

8 HP 10 HP 12 HP 14 HP 16 HP 18 HP 20 HP 22 HP

Cooling capacity kW 22,4 28,0 33,5 40,0 45,0 50,4 56,0 61,5

Heating capacity kW 25,0 31,5 37,5 45,0 50,0 56,0 63,0 64,0

Connectable indoor units 18 22 27 31 36 40 45 49

ModelCapacity

MMY- AP2416HT8P-E AP2616HT8P-E AP2816HT8P-E AP3016HT8P-E AP3216HT8P-E AP3416HT8P-E AP3616HT8P-E AP3816HT8P-E24 HP 26 HP 28 HP 30 HP 32 HP 34 HP 36 HP 38 HP

Combinations 12 + 12 14 + 12 16 + 12 16 + 14 16 + 16 18 + 16 20 + 16 22 + 16

Cooling capacity kW 67,0 73,5 78,5 85,0 90,0 95,4 101,0 106,5

Heating capacity kW 75,0 82,5 87,5 95,0 100,0 106,0 113,0 114,0

Connectable indoor units 54 58 63 64 64 64 64 64

ModelCapacity

MMY- AP4016HT8P-E AP4216HT8P-E AP4416HT8P-E AP4616HT8P-E AP4816HT8P-E40 HP 42 HP 44 HP 46 HP 48 HP

Combinations 20 + 20 22 + 20 22 + 22 16 + 16 + 14 16 + 16 + 16

Cooling capacity kW 112,0 117,5 123,0 130,0 135,0

Heating capacity kW 126,0 127,0 128,0 145,0 150,0

Connectable indoor units 64 64 64 64 64

ModelCapacity

MMY- AP5016HT8P-E AP5216HT8P-E AP5416HT8P-E AP5616HT8P-E AP5816HT8P-E AP6016HT8P-E50 HP 52 HP 54 HP 56 HP 58 HP 60 HP

Combinations 18 + 16 + 16 20 + 16 + 16 22 + 16 +16 20 + 20 +16 22 + 20 + 16 22 + 22 + 16

Cooling capacity kW 140,4 146,0 151,5 157,0 162,5 168,0

Heating capacity kW 156,0 163,0 164,0 176,0 177,0 178,0

Connectable indoor units 64 64 64 64 64 64

TOSHIBA I 71

AD

DIT

ION

AL

INFO

RM

ATIO

N

ModelCapacity

MMY- AP2026HT8P-E AP2226HT8P-E AP3626HT8P-E AP3826HT8P-E AP4026HT8P-E20 HP 22 HP 36 HP 38 HP 40 HP

Combinations 10 + 10 12 + 10 12 + 12 + 12 14 + 12 + 12 14 + 14 + 12

Cooling capacity kW 56,0 61,5 100,5 107,0 113,5

Heating capacity kW 63,0 69,0 112,5 120,0 127,5

Connectable indoor units 45 49 64 64 64

ModelCapacity

MMY- AP4226HT8P-E AP4426HT8P-E AP5426HT8P-E42 HP 44 HP 54 HP

Combinations 14 + 14 + 14 16 + 14 + 14 20 + 20 +14

Cooling capacity kW 120,0 125,0 152,0

Heating capacity kW 135,0 140,0 171,0

Connectable indoor units 64 64 64

VRF performance tables SMMS-e High efficient models

72 I TOSHIBA

P R I C E L I S T – ADDITIONAL INFORMATIONA

DD

ITIO

NA

LIN

FOR

MAT

ION

Measuring conditions for determining the sound pressure level

Duct unit

Measuring conditions for TOSHIBA air-conditioners

Cooling: Outdoor air temperature: + 35 °C DB temperature Indoor air temperature: + 27 °C DB temperature /+ 19 °C WB temperature Humidity: 50-55% relative humidityHeating: Outdoor air temperature: + 7°C DB temperature /+ 6 °C WB temperature Indoor air temperature: + 20°C DB temperatureRefrigerant pipses: 7,5 m length - no height difference between indoor and outdoor unitSound pressure level: measured in about 1,5 m distance to the indoor unit and 1 m distance to the outdoor unit these values are determined in an anechoic chamber in accordance with JIS B8616; in the installed state, these values may be higher because of external factors influence

1 m1 m

1 m

1,5 m

1 m

1 m

Microphone Microphone

Microphone

Hi-wall

Outdoor units DI, S-DI, DI BIG

Ceiling

1 m1 m

Microphone

Console

Sound pressure level: measured in about 1,5 m distance to the indoor unit and 1 m distance to the outdoor unit these values are determined in an anechoic chamber in accordance with JIS B8616; in the installed state, these values may be higher because of external factors influence

4-way cassette60 x 60 4-way cassette

Microphone

Microphone

TOSHIBA I 73

AD

DIT

ION

AL

INFO

RM

ATIO

N

Glossar

A heat pump is a technical unit that produces useful heat from ambient temperature (about 75 percent) and compressor energy (about 25 percent).

Under inverter technology is meant converting alternating current to direct currentto control the compressor speed efficiently and almost without loss.

The efficiency is the direct comparison between the value expended electrical power and got heating / cooling capacity.

See definition „efficiency“ to one year.

Full load is an operation state in which a machine maximum power output canprovide.

Partial load is an operation state which is reached by speed adjustment due to therequired capacity requirement of the room.

A compressor is a component which is required for compressing gas.

The converted voltage by the „Inverter“ can push the compressor in two ways. Eitherthe pulse width modulation (low voltage / PWM) for a very efficient operation atpartial load or the pulse amplitude modulation (high voltage / PAM) for fast reaching the set temperature will be applied.

Sound power is an acoustic variable which occurs at the actual sound source. It is expressed in dB (A).

Sound pressure is the result of the acoustic power depending on the distance to the sound source. It is measured in dB (A).

The ideal unit performance at a given operating point.

The maximum unit performance at a given operating point.

It interrupts an electric circuit when the electric current exceeds a predeterminedcurrent level for a predetermined time or a short-circuits or short to ground occurs onthe electrical load.

Calculated cooling capacity of the room to be cooled at 35°C ambient temperature.

Calculated heating capacity of the room to be heated at well-defined outside temperature.

Refrigerant is a technical mixture gas, which is used within the system as a medium for the transport of cold and heat energy. Common refrigerants are currently R410A and R32, the trend is in the future towards R32. R32 has a lower global warming potential, energy efficiency is still high and plants with R32 need a smaller capacity.

Heat pump

Inverter technology

Efficiency

Seasonal efficiency

Full load

Partial load

Compressor

PWM, PAM

Sound power

Sound pressure

Nominal capacity

Maximal capacity

Electrical protection

Pdesignc

Pdesignh

Refrigerant

74 I TOSHIBA

TOSHIBA I 75

www.toshiba-aircondition.com

TOSHIBA distributed by:

Sub

ject

to

typo

grap

hica

l and

oth

er e

rror

s: E

N /

PR

ICE

/ 0

2. 2

016

AIR

-CO

ND

Klim

aanl

agen

-Han

dels

gese

llsch

aft

m.b

.H.,

Hau

sham

er S

traß

e 2,

A-8

054

Gra

z-S

eier

sber

g, A

ustr

ia, T

el.:

+43

316

80

89, F

ax: +

43 3

16 8

2 63

71,

E-m

ail:

offic

e@ai

r-co

nd.c

om, w

ww

.air-

cond

.com