12 HC IMW INDUSTRIES LTD. 2010/04/19 DO NOT USE AS THE BASIS FOR MANUFACTURE OR SALE OF APPARATUS WITHOUT PERMISSION.

11

10

9

8

7

6

5

4REV. A

3DATE 2010/04/19 BY BJN CK. KWH DCR# N/A

2REVISION HISTORY

1REFERENCE FIRST RELEASE BASED ON 206755

H

COMPRESSOR SKID MOUNTED INDEPENDENTLY OF ENCLOSURE

2

1

5

G6 STUB-UPS FOR POWER/CONTROL AT OUTER EDGE OF ENCLOSURE119 1/4" 90 5/16"

G

F

5

F

124"

3

4

144 7/16"

REMOVABLE ALUMINUM DOORS AND WALL PANELS ISOMETRIC VIEW

E

TOP VIEW ROOF PANELS REMOVED REAR VIEW DOORS REMOVED AIR OUTLET WITH GRAVITY LOUVERS AND LINED WITH ACOUSTIC FOAM

E

7 120V JUNCTION BOX

D4

ACOUSTIC INLET LOUVER

INTRINSIC JUNCTION BOX

D

380V JUNCTION BOX

C8 1/2"

GAS OUTLET: ALL 3/4" TUBE DISPENSER HIGH, MEDIUM, LOW STORAGE HIGH, MEDIUM GAS INLET: 1" TUBE

MAIN MOTOR CONDUIT ENTRY

C12"

2

3

1

2 1/2" TYP. 73 1/2"

32 1/8" 39 3/4" 23 1/8"

8"

FRONT VIEW ENCLOSURE REMOVED

FRONT VIEW DOORS REMOVED

BITEM QTY NO. 1 2 3 4 5 1 1 1 1 1 1 1 PART NUMBER 203523-00 SKID WELDMENT 206573 321806 205149 CBA SUBASSEMBLY MOTOR 445T COOLER SUBASSEMBLY 240027/64/94/142 TANK REC RT1200-120-H CHINA CERT ENCLOSURE ASSEMBLY-RECESSED PANEL-IMW 50 DESCRIPTION UOM EA EA EA EA EA EA EA SPEC. n/a n/a n/a n/a CS n/a SHIPPED LOOSE WEIGHT 1132.5 3647.7 1495.2 2151.7 1730 2092.5 4.2

A

6 7

203399-00 VENT ASSEMBLY - IMW50 & ALPHA3

NOTES: 1. THE LOCATION OF THIS EQUIPMENT IS NOT NECESSARILY AS DEPICTED. THIS DRAWING IS NOT AN EXACT SPECIFICATION TO THOSE ASSEMBLING THE PACKAGE. 2. THE LOCATIONS GIVEN FOR THE ELECTRICAL AND GAS CONNECTIONS ARE APPROXIMATE ONLY. 3. COMPRESSOR MUST BE LOCATED ON A FLAT AND LEVEL CONCRETE FOUNDATION AS SPECIFIED IN THE INSTALLATION SECTION OF THE USER MANUAL. 4. ANCHOR BRACKETS ARE PROVIDED TO SECURE SKID TO ITS FOUNDATIONS. IMW RECOMMENDS THAT ALL ANCHORS BE SET WITH THE EQUIPMENT IN PLACE. IMW ALSO RECOMMENDS THE USE OF "HILTI" ANCHORS, DETAILS OF WHICH WILL BE PROVIDED UPON REQUEST. IMW DOES NOT ACCEPT ANY LIABILITY FOR ALTERNATIVE FASTENING METHODS OR THE THE QUALITY OR SUITABILITY OF THE FOUNDATION. 5. REMOVE LIFTING PINS BEFORE BOLTING DOWN SKID AND ENCLOSURE AND INSTALL SUPPLIED ANCHOR BRACKETS. 6. TO ENSURE ADEQUATE AIR MOVEMENT, NO WALL SHOULD BE CLOSER THAN TEN FEET FROM THE AIR INLETS OR OUTLETS SHOWN. 7. ALL ELECTRICAL CONNECTIONS WILL BE MADE THROUGH THE ELECTRICAL PASS THROUGH SHOWN. 8. ELECTRICAL CLASSIFICATION INSIDE THE ENCLOSURE IS CLASS I, DIV 1, GROUP D. 9. ELECTRICAL CLASSIFICATION OUTSIDE THE ENCLOSURE UP TO 15 FEET IS CLASS 1, DIV 2, GROUP D. 10. ALL ELECTRICAL CONDUIT OR CABLE MUST BE SEALED FOR CLASS1, DIV. 2 GROUP D UPON EXITING THE CLASSIFIED LOCATION.

87"

RIGHT VIEW

B

IMW Industries Ltd. Chilliwack, BC, Canada TITLE

COMPRESSOR IMW50 3X1750SA-100-3625-2ACREF. STANDARD DR. BJN CK. KWH AP. SIZEFILE. NO.

2010/04/19 2010/04/19

DSCALE

240027 DWG. NO. MRP ID 2400271:24 WEIGHT 13500 LBS SHEET

REV

A1 / 1

A

12

11

10

9

8

7

6

5

4

3

2

1