2893 The Value of Credentialing J. Leif, J. Roll, D. Followill, G. Ibbott M.D. Anderson Cancer Center, Houston, TX Purpose/Objective(s): The Radiological Physics Center (RPC) has performed credentialing of institutions to participate in a number of protocol studies. The purpose of credentialing is to verify that the radiation oncologist and other personnel involved are familiar with the protocol prior to enrolling patients with the goal of limiting the number of deviations. Credentialing has been performed for high and low dose rate brachytherapy studies, stereotactic studies and IMRT studies. Credentialing has also been done for several different study groups and for a variety of disease sites including eye, brain, breast, and cervix. Materials/Methods: Over the years, the RPC’s credentialing procedures have required one or more of the following: review of the institution’s physics and QA procedures, submission of knowledge assessment and facility questionnaires, calculation of geometric benchmark cases, importing and planning on a predetermined CT image set, irradiating an anthropomorphic phantom, and submitting the first 2 patients for review. The credentialing process not only evaluated the quality of the specific clinical procedure at the institution, but also assured that the institution and participating radiation oncologist had experience in the procedure. The credentialing process enabled us to offer feedback to the institution to correct mistakes that may occur with a protocol patient. A retrospective review of radiotherapy of patients entered on the studies was performed. A recalculation of patient dose and a review of the records and all planning and verification films were performed. Deviations from protocol guidelines were assessed according to predefined criteria. Results: Three protocols for which credentialing was required of all participants had rates of deviation on the order of 0% to 4% and two protocols that had limited credentialing requirements had rates of deviation on the order of 7% to 17%. In another study some institutions were credentialed for one technique but not for another. Those institutions that were credentialed received no deviations on the protocol, whether they utilized the technique for which they were credentialed or not, while those institutions not credentialed had a deviation rate of 16%. Conclusions: It appears that institutions that go through a credentialing process were better prepared to comply with the requirements of the protocol. This may be because the credentialing process provides feedback on how to better comply with the treatment protocol prior to submitting a patient onto the study. Therefore, the frequency of deviations can be reduced for institutions that go through the credentialing process. QA is an important component of clinical trials. A credentialing procedure can be a valuable component of clinical trial QA. This work was supported by PHS grants CA 10953 and CA081647 awarded by NCI, DHHS. Author Disclosure: J. Leif, None; J. Roll, None; D. Followill, None; G. Ibbott, None. 2894 Lessons From the In-Vivo TLD Dosimetry Practice for Patients Treated With Total Skin Electron Radiation Therapy (TSEB) at M.D. Anderson Cancer Center R. C. Tailor, N. B. Tolani, G. S. Ibbott, C. S. Ha UT MD Anderson Cancer Center, Houston, TX Purpose/Objective(s): At institutions offering TSEB, it is often customary to determine the actual radiation dose at multiple sites of patients with thermoluminescent dosimetry (TLD). These measurements facilitate adjustments to the patient position and orientation to achieve dose uniformity and help determine the need for boost treatment. This practice is time consuming and sometimes uncomfortable for the patient, and requires considerable resources. This report describes statistics of TLD results for a large population of patients treated on a single linac, and an evaluation of the rationale for the number of in-vivo TLD measurements. Materials/Methods: Results of TLD measurements at 22 body sites of each of 68 patients treated with TSEB were evaluated. Patients were treated with a modified Stanford 6-field technique using 9 MeV electron beam. For each measured body site, the mean dose and associated standard deviation were determined. Results: The table below presents statistical results of in-vivo TLD on 68 patients at MDACC. The results are consistent with commissioning data and are compared to those from Chen et. al. (IJROBP 59, P 872– 885, 2004). Despite variations in patient size and uncertainties in positioning, TLD results at main body sites (1– 6) show good reproducibility: one standard deviation 7%. Several other sites show considerable variation from one patient to the next: inner thighs, buttocks, axillae, vertex of scalp, and feet. Conclusions: In-vivo dosimetry for treatments such as TSEB continues to play an important role by providing data for making clinical decisions on the adequacy of dose delivery. Sites 1– 4 are valuable for verifying the reference dose. Upper thorax sites (5, 6) show consistency among patients and could be dropped. Since the TLD results at sites 7–12 show large variations among patients and within the same patient (data not shown), decisions to boost or shield are primarily based on clinical judgment. The feet almost always receive a higher dose than prescribed, and therefore clinical experience dictates that shielding will be required. Consequently, the use of TLD at sites 7–12 and 21–22 may be discontinued. Site such as the back of hand may be useful because differences in left and right may indicate incorrect patient orientation. A careful reduction in the number of in-vivo TLD measurement sites could not only reduce the time and effort required, but more importantly lessen discomfort to these patients. S716 I. J. Radiation Oncology Biology Physics Volume 66, Number 3, Supplement, 2006

Upload: g

Post on 21-Jun-2016

215 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: 2893

2893 The Value of Credentialing

J. Leif, J. Roll, D. Followill, G. Ibbott

M.D. Anderson Cancer Center, Houston, TX

Purpose/Objective(s): The Radiological Physics Center (RPC) has performed credentialing of institutions to participate in anumber of protocol studies. The purpose of credentialing is to verify that the radiation oncologist and other personnel involvedare familiar with the protocol prior to enrolling patients with the goal of limiting the number of deviations. Credentialing hasbeen performed for high and low dose rate brachytherapy studies, stereotactic studies and IMRT studies. Credentialing has alsobeen done for several different study groups and for a variety of disease sites including eye, brain, breast, and cervix.

Materials/Methods: Over the years, the RPC’s credentialing procedures have required one or more of the following: reviewof the institution’s physics and QA procedures, submission of knowledge assessment and facility questionnaires, calculation ofgeometric benchmark cases, importing and planning on a predetermined CT image set, irradiating an anthropomorphicphantom, and submitting the first 2 patients for review. The credentialing process not only evaluated the quality of the specificclinical procedure at the institution, but also assured that the institution and participating radiation oncologist had experiencein the procedure. The credentialing process enabled us to offer feedback to the institution to correct mistakes that may occurwith a protocol patient. A retrospective review of radiotherapy of patients entered on the studies was performed. A recalculationof patient dose and a review of the records and all planning and verification films were performed. Deviations from protocolguidelines were assessed according to predefined criteria.

Results: Three protocols for which credentialing was required of all participants had rates of deviation on the order of 0% to4% and two protocols that had limited credentialing requirements had rates of deviation on the order of 7% to 17%. In anotherstudy some institutions were credentialed for one technique but not for another. Those institutions that were credentialedreceived no deviations on the protocol, whether they utilized the technique for which they were credentialed or not, while thoseinstitutions not credentialed had a deviation rate of 16%.

Conclusions: It appears that institutions that go through a credentialing process were better prepared to comply with therequirements of the protocol. This may be because the credentialing process provides feedback on how to better comply withthe treatment protocol prior to submitting a patient onto the study. Therefore, the frequency of deviations can be reduced forinstitutions that go through the credentialing process. QA is an important component of clinical trials. A credentialing procedurecan be a valuable component of clinical trial QA.

This work was supported by PHS grants CA 10953 and CA081647 awarded by NCI, DHHS.

Author Disclosure: J. Leif, None; J. Roll, None; D. Followill, None; G. Ibbott, None.

2894 Lessons From the In-Vivo TLD Dosimetry Practice for Patients Treated With Total Skin ElectronRadiation Therapy (TSEB) at M.D. Anderson Cancer Center

R. C. Tailor, N. B. Tolani, G. S. Ibbott, C. S. Ha

UT MD Anderson Cancer Center, Houston, TX

Purpose/Objective(s): At institutions offering TSEB, it is often customary to determine the actual radiation dose at multiplesites of patients with thermoluminescent dosimetry (TLD). These measurements facilitate adjustments to the patient positionand orientation to achieve dose uniformity and help determine the need for boost treatment. This practice is time consumingand sometimes uncomfortable for the patient, and requires considerable resources. This report describes statistics of TLD resultsfor a large population of patients treated on a single linac, and an evaluation of the rationale for the number of in-vivo TLDmeasurements.

Materials/Methods: Results of TLD measurements at 22 body sites of each of 68 patients treated with TSEB were evaluated.Patients were treated with a modified Stanford 6-field technique using 9 MeV electron beam. For each measured body site, themean dose and associated standard deviation were determined.

Results: The table below presents statistical results of in-vivo TLD on 68 patients at MDACC. The results are consistent withcommissioning data and are compared to those from Chen et. al. (IJROBP 59, P 872–885, 2004). Despite variations in patientsize and uncertainties in positioning, TLD results at main body sites (1–6) show good reproducibility: one standard deviation 7%. Several other sites show considerable variation from one patient to the next: inner thighs, buttocks, axillae, vertex of scalp,and feet.

Conclusions: In-vivo dosimetry for treatments such as TSEB continues to play an important role by providing data for makingclinical decisions on the adequacy of dose delivery. Sites 1–4 are valuable for verifying the reference dose. Upper thorax sites(5, 6) show consistency among patients and could be dropped. Since the TLD results at sites 7–12 show large variations amongpatients and within the same patient (data not shown), decisions to boost or shield are primarily based on clinical judgment. Thefeet almost always receive a higher dose than prescribed, and therefore clinical experience dictates that shielding will berequired. Consequently, the use of TLD at sites 7–12 and 21–22 may be discontinued. Site such as the back of hand may beuseful because differences in left and right may indicate incorrect patient orientation. A careful reduction in the number ofin-vivo TLD measurement sites could not only reduce the time and effort required, but more importantly lessen discomfort tothese patients.