GSM Macro, high density,12TRX, indoor base station. Highly integrated (fewer cables and connections) and
compact, footprint-0.24sq.mm. Stacking one above other gives impressive ratio -
100TRX/Sq.meter. Total cost of ownership (TCO) is reduced as every
parameter’s performance is improved. Higher output with lesser power consumption. Can work in higher ambient temperature, reduction in fans
and cooling agents inside the shelter, room etc. Supports for both capacity and coverage requirements.
RBS 2964 Product Highlights
![Page 3: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/3.jpg)
RBS 2964- A glance
![Page 4: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/4.jpg)
Technical specifications
![Page 5: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/5.jpg)
900 system data
![Page 6: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/6.jpg)
1800 system data
![Page 7: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/7.jpg)
POWER options
![Page 8: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/8.jpg)
Power recommendations
![Page 9: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/9.jpg)
Power consumption
• Max. power consumption is <=5172w at 200-250VAC.
• Max power is consumed during the initial charging of batteries.
• All PSUs ( 3PSUS/cabinet) are recommended with 1500W each.
• PSU efficiency not <= 87%.
• Hence, (3x1500)/0.87~5172W.
![Page 10: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/10.jpg)
RBS2964/2216 consists of
1. ACCU-Alternating current connection unit(2216).
2. DCCU-Direct current connection unit(2216/2964).
3. Distribution Switch Unit-DXU-31(2216/2964).
4. Dual Radio Unit-DRU.(2964/2216)
5. Fan Control Unit –FCU.(2964/2216)
6. Internal Distribution Module- IDM.(2964/2216)
7. Power Supply Unit-PSU(2216)
8. Receiver Splitter.(2216)
9. Optional TMA Control Module-TMA-CM.(2216/2964)
![Page 11: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/11.jpg)
DXU-31
Supports:
1. System interface with 2/1.5Mbps links
2. Supports LAPD (Conc, Unconc and Mux)
3. Four Transmission ports( Port A,B,C and D), Multidrop
4. Radio network sync, through GPS receiver
5. TG sync through ESB.
6. Interfaces-T1-1.5Mbps/100ohms,
E1-2Mbps-100/120 ohms
![Page 12: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/12.jpg)
ACCU & IDM
• ACCU
Termination point for AC power
• Distributes power to all the PSUs
• Number of units-1
• IDM
• Supplies +24DC to the system
• Has fuses and breakers for protection
• Has +24V DC filter for battery connections
• Number of units-1
![Page 13: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/13.jpg)
PSU
• Gives +24VDC to the system.• Available in two versions.• PSU AC for
200~250VAC(Rectifier).• PSU DC for -48V system.
(converter dc to dc).• Number of units 0-3.• Additional units required to
reduce battery charging times.
![Page 14: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/14.jpg)
DRU-Dual Radio Unit
• Consists of• 2 GSM TRX• Hybrid combiner• 2 TX filter• 2 duplex filters• 2 bias injectors
• Number of units 1-6(12 TRX)
![Page 15: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/15.jpg)
DRU
• Supports• EDGE and GPRS in all time slots• TCC-Transmission Coherent combining, increased cell
radius for downlink
![Page 16: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/16.jpg)
RX splitter
• Shares the RX signals• Used for RX sharing with other
BTSs also.
![Page 17: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/17.jpg)
TMA control module
• Supplies power upto 6 TMAs• Monitors and Controls TMAs• Provides short circuit protection• Supervises cables
• Number of units 0~2
![Page 18: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/18.jpg)
BBS 2216
• Provides 4 hrs of battery back up for indoor site cabinet
• Has BFU, for supervision, connection and disconnection of batteries
![Page 19: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/19.jpg)
MODULAR FLEXIBILITY
![Page 20: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/20.jpg)
2 RBS stacked one above other
![Page 21: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/21.jpg)
RBS AND BBS stacked one above other
![Page 22: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/22.jpg)
SINGLE BAND CONFIG.
![Page 23: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/23.jpg)
Single band Two sector config.
![Page 24: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/24.jpg)
Single band three sectors
![Page 25: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/25.jpg)
DUAL BAND CONFIG 2 SECTORS
![Page 26: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/26.jpg)
DUAL BAND WITH 2 SECTORS
![Page 27: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/27.jpg)
DUAL BAND FOUR SECTORS
![Page 28: 2964](https://reader035.vdocument.in/reader035/viewer/2022062307/552062654979590a3f8b46c0/html5/thumbnails/28.jpg)
DUAL BAND WITH 6 SECTORS