3-phase. power analysis software datasheet

8
3-Phase Power Analysis Software Key Features Complete 3-phase System Debug and Validation Support for 1-phase and 3-phase measurements Measurements for Real, Apparent, Reactive Power Efficiency Measurements User-configurable Numerics Table Two-wattmeter and Three-wattmeter Methods Supported Per-cycle Time-correlated Waveforms From Power Values Harmonics Calculations and Filtering (optional) Unique Zoom+Gate Mode Line-Line To Line-Neutral Voltage Conversion Key Applications Solar PV inverters Grid-tied inverters Uninterruptible Power Supplies (UPS) Welding equipment Power Conversion Systems DC-DC power supplies Complete System Debug Acquire power and control system signals and perform 3-phase power analysis of the power section waveforms. Correlation of system behaviors to embedded control loop signals enables debug and analysis of all aspects of a 3-phase electrical system. Numerics Measurement Table Various voltage, current, power (real, apparent, and reactive), phase angle/ power factor, and efficiency parameters are calculated on acquired voltage and current waveforms and displayed in a table. The table is displayed along with the acquisition waveforms. Zoom+Gate Dynamic Analysis Capture long acquisitions and Zoom+Gate with instant table value updates and views of dynamic 3-phase power performance. 3-phase Two-wattmeter Method Support Two-wattmeter measurement method is supported, allowing 3-phase power measurements to be made using two voltage and two current signals. Therefore, 3-phase measurements can be made using 4 channels instead of 6. Teledyne LeCroy’s 3-Phase Power Analysis software package provides complete 3-phase electrical power analysis. Static power results are in a convenient, configurable Numeric table, and dynamic power results are displayed as per-cycle Waveforms. Zoom+Gate mode provides ability to understand and isolate dynamic behaviors. All aspects of system debug and validation on any building block (AC-AC, AC-DC, DC-DC, DC-AC) of a Power Conversion system can now be easily performed.

Upload: others

Post on 13-May-2022

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 3-phase. Power Analysis Software Datasheet

3-Phase Power Analysis Software

Key Features

Complete 3-phase System Debug and Validation

Support for 1-phase and 3-phase measurements

Measurements for Real, Apparent, Reactive Power

Efficiency Measurements

User-configurable Numerics Table

Two-wattmeter and Three-wattmeter Methods Supported

Per-cycle Time-correlated Waveforms From Power Values

Harmonics Calculations and Filtering (optional)

Unique Zoom+Gate Mode

Line-Line To Line-Neutral Voltage Conversion

Key Applications – Solar PV inverters – Grid-tied inverters – Uninterruptible Power Supplies (UPS) – Welding equipment – Power Conversion Systems – DC-DC power supplies

Complete System DebugAcquire power and control system signals and perform 3-phase power analysis of the power section waveforms. Correlation of system behaviors to embedded control loop signals enables debug and analysis of all aspects of a 3-phase electrical system.

Numerics Measurement TableVarious voltage, current, power (real, apparent, and reactive), phase angle/power factor, and efficiency parameters are calculated on acquired voltage and current waveforms and displayed in a table. The table is displayed along with the acquisition waveforms.

Zoom+Gate Dynamic AnalysisCapture long acquisitions and Zoom+Gate with instant table value updates and views of dynamic 3-phase power performance.

3-phase Two-wattmeter Method SupportTwo-wattmeter measurement method is supported, allowing 3-phase power measurements to be made using two voltage and two current signals. Therefore, 3-phase measurements can be made using 4 channels instead of 6.

Teledyne LeCroy’s 3-Phase Power Analysis software package provides complete 3-phase electrical power analysis. Static power results are in a convenient, configurable Numeric table, and dynamic power results are displayed as per-cycle Waveforms. Zoom+Gate mode provides ability to understand and isolate dynamic behaviors. All aspects of system debug and validation on any building block (AC-AC, AC-DC, DC-DC, DC-AC) of a Power Conversion system can now be easily performed.

Page 2: 3-phase. Power Analysis Software Datasheet

2

MORE CAPABILITY THAN YOU EVER IMAGINED

4. Two-wattmeter Method Use Two-wattmeter method to make accurate 3-phase power measurements using just two voltage and two current signals.

5. Multi-Stage Power Analysis with Efficiency Calculated stage-stage and overall (cumulative) efficiency independently for greater understanding.

The 3-Phase Power Analysis software provides an extensive range of capabilities to allow you to debug your 3-phase power conversion system design faster than ever before

1

2

1. Numerics Table User-definable and quickly summarizes the mean value for the entire acquisition - like the static power calculation in a Power Analyzer.

2. Statistics TableDisplays the complete measurement set statistical data for any Numerics table measurement.

3. Per-cycle “Synthesized” Waveforms Enhances and speeds understanding of complex behaviors. Note the magenta trace (Total Power) clearly shows power changes as the voltage and current rails fail.

3

4

5

Page 3: 3-phase. Power Analysis Software Datasheet

3

MORE CAPABILITY THAN YOU EVER IMAGINED

1

2

6

9

6. Zoom+Gate Mode Take a single long acquisition of a dynamic event, and with the press of one button, zoom through the waveforms and gate the measurement results to the zoomed area. Change the zoom position and the measurement tables and per-cycle “synthesized” Waveforms update instantly. Gain faster understanding of dynamic system behaviors.

7. Dynamic Power Waveform Displays Simply touch a measurement and a per-cycle “synthesized” Waveform is created showing the change in that measurement over time

8. Per-cycle “Synthesized” Waveforms The Per-cycle waveform updates to the Zoom+Gate window when enabled.

9. Cursors Place a cursor on any waveform and get an instantaneous reading of system behavior

7

8

9

Page 4: 3-phase. Power Analysis Software Datasheet

4

BEYOND “NUMBERS” - MORE INFORMATION

Like a power analyzer, a user-configurable table is provided for display of a selection of power (real, apparent, reactive), power factor, phase angle, efficiency, voltage, or current parameters. Up to 120 values total may be displayed in 10 rows and 12 columns for any selection of input or output individual phase or total 3-phase, or DC bus/link values.

The numeric values displayed are mean values from a statistical data set that is calculated on a “per-cycle” basis using a user-defined synchronization source signal. This display corresponds to what is normally provided by a dedi-cated power analyzer instrument.

Per-cycle “Synthesized” WaveformsA single averaged value “hides” dynamic behaviors. Simply “touch” the value in the Numerics table and a detailed per-cycle Waveform will be created from the complete per-cycle measurement set and then automatically displayed time-correlated to the original acquisition. Statistical values (min, max, number, etc.) can also be displayed. Use this advanced capability to correlate complex power conversion system behaviors to other control or power system waveforms, and to debug drive system problems. This capability is not provided in any Power Analyzer instrument.

Zoom+Gate ModeEnable Zoom+Gate mode to create zooms of all channel acquisitions and gate the Numerics and Statistics mea-surement tables to the zoomed area. Per-cycle displayed Waveforms will be zoomed and time-correlated to the other Zoomed waveforms. Change the zoom location and size and the data will instantly update. Scroll quickly through your measurement set to gain fast and deep insight into dynamic power conversion system behavior.

Numerics Measurement Table

This 10 second capture on a HDO8000A shows the output PWM voltage and current waveforms on the left. The Total Power and Power Factor Waveform per-cycle values over time are shown to the right.

Page 5: 3-phase. Power Analysis Software Datasheet

5

3-phase power measurements can be made using either the three-wattmeter or two-wattmeter method. An 8 channel oscilloscope allows direct measurement of three voltage and three current signals (three-wattmeter method). Support is provided for a Line-Line to Line-Neutral voltage conversion so as to allow intuitive line-line probing with per-phase line-neutral reported results.

A 4 channel oscilloscope can also make 3-phase power measurements using the two-wattmeter measurement method. This is done by measuring two voltage and two current signals.

On an 8 channel scope, two-wattmeter measurement support allows input/output efficiency measurements of the complete power conversion system to be performed (4 channels for input V & I measurement + 4 channels for output V & I measurement).

Flexible Setup Capability

Capability Comparison

THREEPHASEPOWER on HDO6000B & WavePro HD

THREEPHASEPOWER on WaveRunner 8000HD

MDA 8000HD Motor Drive Analyzer

Analog Input Channels 4 8 (16 with OscilloSYNC) 8 (16 with OscilloSYNC)

Digital Input Channels 16 (on -MS models) 16 (with MSO option) 16 (with MSO option)

Resolution 12 bits 12 bits 12 bits

Bandwidth 350 MHz - 8 GHz 350 MHz - 2 GHz 350 MHz - 2 GHz

1-Phase Power Analysis

3-Phase Power Analysis (2-wattmeter method only)

Mechanical Power Analysis X X

X-Y Traces X X

Harmonics Calc Option

Vector Display Option

Waveform Transformation Option (αβγ & dq0 only)

(αβγ & dq0 only)

Page 6: 3-phase. Power Analysis Software Datasheet

6

HARMONICS, VECTOR DISPLAY, DQ0 TRANSFORMS

Harmonics Calculations (Optional)• Rigorous software DFT method precisely

separates desired frequency content.

• Calculates AC line-side (fixed-frequency) or inverter/drive output (variable-frequency).

• Adds "Fundamental + N" and "Range" selections to Harmonic Filter settings.

• THD numeric calculation and per-cycle Waveforms.

• Harmonic order table and spectral displays (up to nine simultaneous).

Vector Displays (Optional)• Two simultaneous displays.

• Zoom+Gate and harmonically filter to show vector changes during dynamic events.

Waveform Transformations (Optional)• View two simultaneous αβγ (Clarke) & dq0

(Park) real-time transformations.

• X-Y plot capability available for d vs. q and α vs. β components.

αβγ (Clarke) transformed waveforms.

Capture and calculate harmonics during very short or long acquisitions and show results as Spectral Waveform displays, total THD values or per-cycle THD Waveforms.

Display 2 simultaneous vector views of 3-phase power systems.

Page 7: 3-phase. Power Analysis Software Datasheet

7

THREEPHASEPOWER CapabilitiesSetup CapabilityMeasurement Locations Input, DC Bus, OutputWiring Configurations Input:

3-phase / 4-wire (3V3A) [WR8KHD only]; 3-phase / 3-wire (3V3A) [WR8KHD only]; 3-phase / 3-wire (2V2A); 1-phase / 3-wire (2V/2A); 1-phase / 2-wire (1V1A); None

DC Bus: 1-phase / 2-wire (1V1A); None

Output: 3-phase/ 4-wire (3V3A) [WR8KHD only]; 3-phase / 3-wire (3V3A) [WR8KHD only]; 3-phase / 3-wire (2V2A); 1-phase / 3-wire (2V/2A); 1-phase / 2-wire (1V1A); None

Harmonic Filter Select either Full Spectrum or Fundamental only. With the THREEPHASEHARMONICS option, also select Fundamental + N Harmonics or Range (maximum 50th harmonic in both cases).

Sync (per-cycle) Measurement Signal Independently settable for Input, DC Bus, Output Low pass filter (LPF) cutoff settable from 20 Hz to 1 MHz. Hysteresis settable from 0-100% full amplitude.Source can be any input analog channel, memory trace, or math function.

Voltage Measurement Method Line-Line or Line-Neutral (with L-L to L-N conversion supported).Calculation Waveform Sources Any input channel or stored memory trace.

Numerics Measurement Table Selections (Per-cycle Calculated, Mean Value Displayed)Voltage RMS voltage, AC Voltage, DC Voltage, Peak Positive Voltage, Peak Negative Voltage, Peak-Peak Voltage,

Voltage Crest Factor, Voltage Total Harmonic Distortion (THD) (with the THREEPHASEHARMONICS option).Current RMS Current, AC Current, DC Current, Peak Positive Current, Peak Negative Current, Peak-Peak Current,

Current Crest Factor, Current Total Harmonic Distortion (THD) (with the THREEPHASEHARMONICS option).Power, Efficiency, + Other Real, Apparent, and Reactive Power, Peak Positive Real Power, Peak Negative Real Power, Power Total Harmonic

Distortion (THD) (with the THREEPHASEHARMONICS option), Power Factor, Phase Angle, Incremental Efficiency, Total Efficiency, Frequency.

Source Selections Voltage: Va, Vb, Vc, Va-b, Vb-c, Vc-a, Vr, Vs, Vt, Vr-s, Vs-t, Vt-r, Ia, Ib, Ic, Ir, Is, It, Vbus, Ibus. Up to 10 rows (sources) and 12 columns (measurements) may be displayed in the table at any time. Source selections dependent on Wiring Configuration selections and Line-Line to Line-Neutral selections.

Per-cycle “Synthesized” Waveforms and StatisticsWaveforms A time-correlated waveform of any per-cycle Numerics Table measurement parameter may be created and dis-

played anywhere on the grid. Up to 12 detailed per-cycle Waveforms may be displayed at one time, with up to 40 waveforms total (channels, memories, zooms, math, and per-cycle Waveforms) displayed at any one time.

Statistics Detailed statistics on up to 12 per-cycle Numerics Table measurement parameters may be displayed at one time.

Zoom+Gate ModeOperation Press “Zoom+Gate” button to create zooms of all voltage and current signals, and simultaneously gate the Nu-

merics and Statistics tables to the zoomed area. Displayed per-cycle “synthesized” Waveforms are simultaneously time-correlated to the zoomed area. Scroll through the full acquisition using Zoom position and ratio (size) controls and view instantaneous updates of table values.

Typical AccuracyVoltage, Current and Power Typically within 1%, depending on voltage and current measurement device.

Recommended voltage probe (line-line voltage sensing) = Teledyne LeCroy HVD Series High Voltage Differential Probe (1kV, 2kV and 6kV isolated models available).Recommended voltage probe (line-neutral or line-reference voltage sensing) = Teledyne LeCroy HVD Series HV Dif-ferential Probe for voltages >50Vrms, Teledyne LeCroy passive probe (Qty. 4 included) for voltages <=50VrmsRecommended current probes = Teledyne LeCroy CP Series Current ProbesOther voltage and current measurement devices may be interfaced to the oscilloscope and analysis software using built-in rescaling and unit selection capabilities. The CA10 current sensor adapter provides programmability for rescaling and unit selection.

Harmonics Calculation Option (THREEPHASEHARMONICS)Fundamental Frequency Detection Fixed Frequency Detection mode (for Input only) or Varying Frequency Detection Mode (for Input or Output).Number of Harmonics Calculated Up to 100 (Fixed Frequency) or up to 50 (Varying Frequency).Harmonics Table and Spectral Wave-form Display

Display values by Harmonic Order for up to 9 quantities (Voltage, Current and Power) for any or all of three phases (limited to Voltage and Current in Fixed Frequency mode).

Units/Limits Selection Select from either Amps/Volts/Watts, %, or dB. For Fixed Frequency, selection Limits file or create and assign custom limits file.

Vector Display Option (THREEPHASEVECTOR)Number of Vector Displays Two: one for Input and one for Output.Vector Display Selection Arithmetic or Vector Sum.Display Information Volts, Amps and Phase Angle for each vector.

Waveform Transforms (THREEPHASEDQ0)Transform Locations Input, Output.Transform Method None, αβγ, dq0.Calculation Waveform Sources Any input channel or stored memory trace.

CAPABILITIES & PERFORMANCE

Page 8: 3-phase. Power Analysis Software Datasheet

© 2021 Teledyne LeCroy, Inc. All rights reserved. Specifications, prices, availability, and delivery subject to change without notice. Product or brand names are trademarks or requested trademarks of their respective holders.

three-phase-pwr-sw-ds-29jun21

Local sales offices are located throughout the world. Visit our website to find the most convenient location.

1-800-5-LeCroy teledynelecroy.com

Customer Service Teledyne LeCroy oscilloscopes and probes are designed, built, and tested to ensure high reliability. In the unlikely event you experience difficulties, our digital oscilloscopes are fully warranted for three years and our probes are warranted for one year. This warranty includes:

• No charge for return shipping • Long-term 7-year support • Upgrade to latest software at no charge

Product Description Product Code3-phase Power Analysis software for HDO6000 HDO6K-THREEPHASEPOWER3-phase Harmonics Calculation Option for HDO6000 (only available with HDO6K-THREEPHASEPOWER) HDO6K-THREEPHASEHARMONICS3-phase Vector Display option for HDO6000 (only available with HDO6K-THREEPHASEPOWER ) HDO6K-THREEPHASEVECTOR3-phase dq0 option for HDO6000 (only available with HDO6K-THREEPHASEPOWER) HDO6K-THREEPHASEDQ0

3-phase Power Analysis software for WavePro HD WPHD-THREEPHASEPOWER3-phase Harmonics Calculation Option for WavePro HD (only available with WPHD-THREEPHASEPOWER) WPHD-THREEPHASEHARMONICS3-phase Vector Display option for WavePro HD (only available with WPHD-THREEPHASEPOWER) WPHD-THREEPHASEVECTOR3-phase dq0 option for WavePro HD (only available with WPHD-THREEPHASEPOWER) WPHD-THREEPHASEDQ0

3-phase Power Analysis software for WaveRunner 8000HD WR8KHD-THREEPHASEPOWER3-phase Harmonics Calculation Option for WaveRunner 8000HD (only available with WR8KHD-THREEPHASEPOWER) WR8KHD-THREEPHASEHARMONICS3-phase Vector Display option for WaveRunner 8000HD (only available with WR8KHD-THREEPHASEPOWER) WR8KHD-THREEPHASEVECTOR3-phase dq0 option for WaveRunner 8000HD (only available with WR8KHD-THREEPHASEPOWER) WR8KHD-THREEPHASEDQ0

ORDERING INFORMATION