    NECESSITY OF DC MOTOR STARTER

    INTRODUCTION

    At the time of starting at the DC motor

    N = 0 & Eb = 0.

    We know that Eb = V IaRa

    O = V IaRa

    Fa = V / Ra

    Suppose

    V = 230 V

    Ra = 1

    Therefore, Ia = 220 / 1 = 220A

    Hence at starting the D.C. motor armature will draw very high current &

    this high current will damage the brushes, commutator, armature etc.

    In order to reduce high value of current, starters are necessary.

    3 POINT STARTER

    This type of starter is widely used for starting shunt and compound

    motors.

    OPERATION

    To start with the D.C. supply is switched on with handle in the Off position

    The handle is now moved clockwise to the 1st stud. As soon as it comes in

    contact with the 1st stud the shunt field way is directly connected across

    the supply, while the whole starting resistance is inserted I series with

    armature ckj

  • 7/30/2019 3 Point or 4 Point Starter

    3/5

    As the handle gradually moved over to the final stud, the starting

    resistance is cut out of the armature CKTS in steps. The handle is now

    held magnetically by the no volt release coil which is energized by shunt

    field current.

    In the supply voltage is suddenly interrupted or of the field excitation is

    accidentally cut, the no volt release coil is demagnetized and the handle

    goes back to the Off position under the pull of spring. If no volt release coil

    where not used.

    If motor is overloaded, it will draw excessive current from the supply this

    current will increase the ampere turns of the overload release coil and

    pull the armature, this short circuiting the no-volt release coil. The no volt

    coil is demagnetized and handle is pulled to the Off position by the spring.

    Thus the motor is automatically disconnected from the supply.

    DRAW BACK

    In a 3 Point starter, the no volt release coil is connected in series with

    the shunt field CKT so that it carried the shunt field current.

    4 POINT STARTEROperation

    In a 4-point starter, the no-volt release coil is connected directly the supply

    line through a protective resistance R.

    Now the no-volt release coil CKT is independent of the shunt field CKT.

    Therefore, proper speed control can be exercised without affecting the

    operation of no volt release coil

    Its working is same as like 3 Point starter.

  • 7/30/2019 3 Point or 4 Point Starter

    4/5

  • 7/30/2019 3 Point or 4 Point Starter

    5/5

    Conclusion

    We studied that the 4 Point starter construction is same as 3 Point Starter

    expect the no volt is connected in series with rheostat.

    Reference:

    Book by B.L. Thereja

    Book by V.K. Mehta