300-54372 solix marketing presentation - boc instruments
TRANSCRIPT
![Page 1: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/1.jpg)
Introducing
FullRange™ OCT
PN 300-54372
![Page 2: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/2.jpg)
• FullRange Field of View
Wide: up to 18mm
Deep: up to 6.25mm
Uncompromised 5µm image quality
• FullRange of Clinical Applications
Retina, Glaucoma, Anterior Chamber, Ocular Surface, Wellness
• FullRange of Cutting Edge Technologies
Ultra-high-speed 120kHz scanning
FullRange retina and anterior chamber scans
3D-PAR 2.0
Multi-volume averaging
3D vessel rendering
Single scan protocol for structural and vascular data
FullRange is the Future of OCT
![Page 3: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/3.jpg)
• FullRange anterior segment imaging captures entire anterior chamber in a single scan
• External IR imaging enables evaluation of Meibomian glands of the upper and lower lids without a dedicated imaging device
• Proven glaucoma analytics combine structural and vascular images and measurements
• FullRange retinal imaging allows wide and deep imaging of the retina, choroid and vitreous…even in highly myopic patients
• AngioVue® OCT Angiography (OCTA) for non-invasive 3D visualization and quantification of retinal vasculature*
• Fundus and external color photography
• Wellness capabilities or patients suspected of retinal pathologies and glaucoma
Multi-Functional Platform Provides Comprehensive Diagnostic Tools
![Page 4: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/4.jpg)
Solix TechnologySolix is a new class of OCT based on 27 years of experience in OCT innovation.
![Page 5: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/5.jpg)
Ultra-High-Speed Scanning Produces Large Field of View and Outstanding Resolution
Images courtesy of Alexandra Miere, MD, Créteil University Hospital, France
![Page 6: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/6.jpg)
4 Volumes Merged
Single Volume
Multi-Volume Averaging Delivers High-Density Images with Pristine Clarity
![Page 7: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/7.jpg)
3D PAR 2.0 Improves Artifact Removal in the Deep Plexus
Optovue 3D PAR 2.0Optovue 3D PARNo PAR
![Page 8: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/8.jpg)
New Segmentation Algorithms Improve RPE and BRM Segmentation…Even in Diseased Eyes
Auto Manual Auto Manual
Auto Manual Auto Manual
![Page 9: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/9.jpg)
3D Vessel Rendering Enables Real-Life Visualization of Vascular Connectivity
MacTel with Type 3 NV Type 1 CNV
![Page 10: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/10.jpg)
Anterior Segment
SOLIX FullRange anterior imaging provides stunning views of the entire anterior chamber.
A comprehensive anterior segment package expands the clinical utility of the system to address a broad range of patients.
![Page 11: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/11.jpg)
• Image the entire anterior chamber with the FullRange scan and use the caliper tools to measure ocular structures.
FullRange Anterior Chamber Scan | 18 x 6.25mm
Image courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France
![Page 12: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/12.jpg)
• Shift the scan depth to evaluate opacities and measure the size of the lens prior to cataract surgery.
FullRange Anterior Chamber Scan | 18 x 6.25mm
![Page 13: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/13.jpg)
• Quantify epithelial, stromal and total corneal thickness with the 10mm Corneal Layer Map, which features 16 meridians to fully cover the LRS transition zone.
10mm Corneal Layer Map
Dry Eye Total Corneal & Epithelial Thickness
KeratoconusTotal Corneal & Epithelial Thickness
Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France
![Page 14: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/14.jpg)
• Use the Highlight Tool to further appreciate subtle changes in thickness. The Change Analysis report measures changes in thickness between visits.
Corneal Layer Map Highlight Tool
Epithelial Thickness Map Epithelial Thickness Map with Highlight Tool
![Page 15: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/15.jpg)
• Evaluate Meibomian gland structure of the upper and lower lids without a dedicated instrument.
External IR Imaging
![Page 16: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/16.jpg)
• Document ocular surface conditions without moving the patient to the slit lamp for examination.
External Color Photography
External Color Photograph External Color Photograph with Red Reflex
![Page 17: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/17.jpg)
Case Study | Dry Eye
10mm Epithelial Thickness Map
Cornea Line Scan External IR Image
• Add new information to the diagnosis and management of dry eye patients.
Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France
![Page 18: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/18.jpg)
Case Study | Conjunctival Chalasis
10mm Epithelial Thickness Map
Cornea Line Scan External IR ImageCornea Cube Scan
Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France
![Page 19: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/19.jpg)
Glaucoma
The SOLIX glaucoma package delivers in-depth analysis of the optic nerve head structure and vasculature.
A single scan protocol generates both OCT and OCTA images with AngioAnalytics® metrics to help you quickly understand each patient’s rate of change.
![Page 20: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/20.jpg)
Optic Disc Analysis | Disc Combo Report
• Comprehensive GCC and ONH analysis for baseline glaucoma assessments.
![Page 21: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/21.jpg)
Anterior Segment Analysis | FullRangeAnterior Chamber Scan
Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France
![Page 22: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/22.jpg)
• Track change and estimate the rate of change in both GCC and RNFL thickness with unparalleled reproducibility to easily assess how quickly a patient’s disease is progressing.
ONH + GCC Trend Analysis
![Page 23: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/23.jpg)
AngioDisc Trend Analysis
• Measure the vessel density of the RPCs, assess visit-to-visit change and estimate rate of change in glaucoma patients and suspects. Vessel density analysis complements RNFL and GCC analysis and aids in the management
of advanced glaucoma – especially in cases where neural structural measurements have reached the measurement floor.
![Page 24: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/24.jpg)
Multi-Visit Reports
![Page 25: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/25.jpg)
Retina
SOLIX delivers unprecedented views of the vitreous and choroid – even in highly myopic patients.
A single scan protocol generates all necessary images and data for comprehensive retinal analysis to quickly provides the clinical data your practice demands.
![Page 26: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/26.jpg)
Vitreous Liquefaction and Contraction
• Wide and deep retina scan displays from vitreous to choroid without sacrificing depth resolution…even in highly myopic eyes.
FullRange Retina Scan | 16mm x 6.25mm
Solix: 16mm Wide x 6.25mm Deep
Normal Eye PVD with Traction & ERM
CNV in High Myopia
Images courtesy of Explore Vision Clinic, Paris, France, dil El Maftouhi, Centre Rabelais, Lyon, France and Julie Rodman, NOVA Southeastern University, Ft. Lauderdale, USA
![Page 27: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/27.jpg)
En Face OCT
6.4 x 6.4mm
9 x 9mm
12 x 12mmMontage of Two 9 x 9mm Scans
Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France and Alexandra Miere, MD, Créteil
University Hospital, France
![Page 28: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/28.jpg)
Retina Line Scans
Line Scan6-12mm Width, 3mm Depth
21 Line Raster Scan6-12mm Width, 2-10mm Height, 3mm Depth
12 Line Radial Scan6-12mm Width, 3mm Depth Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France
![Page 29: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/29.jpg)
• Single scan protocol provides all images and data necessary for comprehensive retinal analysis.
3D Volume Scan
![Page 30: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/30.jpg)
• Measure retinal thickness and GCC thickness maps and compare to a reference database.
Retinal & GCC Thickness Maps
![Page 31: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/31.jpg)
• View retinal photos in color, grayscale and inverse modes.
Fundus Photography
Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France
![Page 32: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/32.jpg)
AngioVue® OCT Angiography
6.4 x 6.4mm
9 x 9mm
12 x 12mm
Montage of Four 9 x 9mm ScansImages courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France and Alexandra Miere, MD, Créteil
University Hospital, France
![Page 33: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/33.jpg)
• Real-life visualization of neovascularization
3D OCTA Volume Rendering
MacTel with Type 3 NV Type 1 CNV
Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France
![Page 34: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/34.jpg)
AngioAnalytics™ OCTA Metrics
Flow Area Measurements
Non-Flow Area Measurements
FAZMetrics
Retina Vessel Density
Disc Vessel Density
![Page 35: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/35.jpg)
AngioVue Retina Reports
![Page 36: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/36.jpg)
Case Study | MacTel with Type 3 CNV
Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France
![Page 37: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/37.jpg)
Case Study | Posterior Vitreous Detachmentwith Epiretinal Membrane
Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France
![Page 38: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/38.jpg)
Case Study | Vein Occlusion
Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France
![Page 39: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/39.jpg)
Case Study | Diabetic Retinopathy
Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France
![Page 40: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/40.jpg)
Case Study | Type 1 CNV
Images courtesy of Adil El Maftouhi, Centre Rabelais, Lyon, France
![Page 41: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/41.jpg)
WellnessThe SOLIX wellness protocol can reveal the need for more extensive imaging and streamline the exam process by quickly confirming normal or aiding in more efficient diagnosis of pathology.
![Page 42: 300-54372 Solix Marketing Presentation - BOC Instruments](https://reader031.vdocument.in/reader031/viewer/2022020700/61f52fe0fb3aac094d598735/html5/thumbnails/42.jpg)
Solix Wellness Scan | 12 x 9mm with Fundus Overlay