Section :
30RB
Carrier SCS - France 262 to 802
R410A
Carrier Commercial Systems
2008 LIST PRICES
30RB AIR COOLED CHILLERS
30RB with Option 15
Standard unit delivered with MCHXCoils
-
8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008
2/13
Section :
30RB
Carrier SCS - France 262 to 802
Carrier Commercial Systems
2008 LIST PRICES
These air-cooled packaged chiller units are fully piped and charged with refrigerant HFC-410A.Weatherproof construction, lightweight distribution and small footprint make them ideal for rooftop or ground level installation.
Upward discharge airflow minimizes directional sound and carries heat away from surrounding areas.
30RB 30RB
262-522 602-802
Full Load Factory Run Test Std Std
Compressors
Rotary Scroll Compressors Std Std
Rubber Vibration Isolators Std Std
Across-the-line start Std Std
Compressor Discharge Shutoff Valves per circuit Std Std
Compressor Over temperature Protection (Scroll Protection Module) Std Std
Patented Compressor Anti-Short Cycling Protection Std StdCompressor sound enclosure (note 1) OPT OPT
Crankcase heaters Std Std
Refrigeration circui t
R-410A Refrigerant Charge Std Std
Independent Refrigeration Circuits Std Std
Long-Stroke Electronic Expansion Valve (EXV) Std Std
Moisture Indicating Sight Glass Std Std
High Pressure safety protection by compressor Std Std
Low Pressure Protection Std Std
Filter drier with removeable core Std Std
Manual liquid line shut off valve Std Std
Cooler
Cooler Heater (note 1) OPT OPTCooler Insulation Std Std
Chilled Water Flow Switch Std Std
Low Water Temp Protection Std Std
Safety relief valve Std Std
Condenser
Micro-channel heat exchanger (MCHX) Std Std
Blygold Polual -Coating with traditonnal Cu/Al Condenser Coils (note 2) OPT OPT
Flying Bird IV Low Noise Fans Std Std
Power and Control electrical boxSingle Point Power Entry Std NA
Unit Mounted Non Fused Main Disconnect (note 1) OPT OPT
Hinged Access doors Std Std
24 Volts Control Transformer Std StdControl Display Access Door Std Std
Safeties and Controls
Pro-Dialog control and display Std Std
Two units Automatic Lead/Lag OPT OPT
Temperature & Pressure Display Std Std
Chilled Water Temperature Reset based on Outdoor Air Temperature Std Std
One step Demand Limit Control Std Std
On/Off Chilled water pump control Std Std
Dual set point Std Std
RS 485 CCN port Std Std
Frame and casing
Base rail with anti corrosion protection Std Std
RAL 7035 paint finish on chassis and casing Std StdCoil end side panel (note 1) note 1 note 1
Compressor / Condenser Coils Grilles OPT OPT
Std Standard Feature
OPT Factory-Installed Option
Accy Field-Installed Accessory
N/A Not Available
30RB AIR COOLED CHILLERS
Note 1 :
MAJOR FEATURES
-
8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008
3/13
Section :
30RB
Carrier SCS - France 262 to 802
Carrier Commercial Systems
2008 LIST PRICES
Digit number
Product code
Legend Digits 1 to 3: liquid chiller with rotary scroll compressors
Digit 4: model series, B air cooled cooling only, Q air to water heat pump
Digits 5 to 8: model number based on cooling capacity in kW
Digit 9: not used
Digit 10: index for major product modification (visible impact for customer)
Digit 11 to 14: counter used to generate an one time product code
Digit 15: not used
Digit 16: Country code / P with Montluel 30RB (European PED pressure vessel approval)
Digit 17 & 18, always EE (Montluel production)
List Price in Euros without Europack
Product code List Price
30RB0262- 93 186
30RB0302- 103 144
30RB0342- 113 001
30RB0372- 123 116 30RB0402- 132 024
30RB0432- 138 291
30RB0462- 145 816
30RB0522- 160 035
30RB0602- 182 823
30RB0672- 196 102
30RB0732- 209 261
30RB0802- 222 546
EEP-1000--2620BR03
181716151413121110987654321
-
8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008
4/13
Section :
30RB
Carrier SCS - France 262 to 802
Carrier Commercial Systems
2008 LIST PRICES
Accesso ry code Description Used on List price
00PSG000119100A----- CCN to J-Bus gateway ALL 1 149
Two way protocol converter board between CCN and J-Bus
for easy connection to BMS. To be field installed in the chiller
electrical box. Also available as an option
00PSG000119200A----- CCN to BacNet gateway ALL 1 149
Two way protocol converter board between CCN and BacNet
for easy connection to BMS. To be field installed in the chiller
electrical box. Also available as an option
00PSG000119300A----- CCN to LonTalk gateway ALL 1 149Two way protocol converter board between CCN and Lon
Talk for easy connection to BMS. To be field installed in the
chiller electrical box. Also available as an option
00PSG000119400A----- Energy management module EMM ALL 1 629Provides additional contacts for: Temperature reset (space
temperature and 4-20 mA).Capacity control (4-20mA and 3
steps). Occupancy overide, Chiller capacity, Compressor
running output. Also available as an option00PSG000119500A----- Scrolling Marquee remote user interface ALL 2 069
Remote diplay module for access to unit status, operation,
configuration and troubleshooting diagnostics. Maximum 300
m distance from chiller, needs 230-1-50 power supply
00PSG000119601A----- Victaulic connection s leeve. Diameter 4" (*) 1 048
00PSG000119602A----- Victaulic connection s leeve. Diameter 5" (*) 857
00PSG000119603A----- Victaulic connection s leeve. Diameter 6" (*) 1 026(*) Evaporator connecting pipe delivered with a Victaulic
coupling. Can be welded or threaded on site
CAUTION30RB with/without hydro module have different
water connection diameter Please check your connection
diameter before ordering
00PSG000119701A----- Power electric box extension (**) 30RB0302 to 402 776
00PSG000119702A----- Power electric box extension (**) 30RB0432 to 522 858
00PSG000119703A-----Power electric box extension (**) 2
pieces 30RB0602 to 672 1 547
00PSG000119704A-----Power electric box extension (**) 2
pieces 30RB0732 to 802 1 629
(**) Used to facilitate connection of big size power cable with
large bending radius. Only stripped wires will enter the unit
power box
00PSG000120000A----- Boiler control board ALL 1 058
Used for boiler ON/OFF control. (Aquasmart system) or
electric heater 4 stage control (30RQ Heat pump). To be
installed remotely, needs 400-3-50 power supply
Prodialog Service Simulator A P 30RB
ACCESSORIES - FIELD INSTALLEDNA : Not Available
-
8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008
5/13
Section :
30RB
Carrier SCS - France 262 to 802
Carrier Commercial Systems
2008 LIST PRICES
Option Description Used on Option code List price
2B Condenser with anti-corrosion post-treatment30RB0262-_OPT_002B 12177
30RB0302-_OPT_002B 15221
30RB0342-_OPT_002B 15221
CAUTION : NEW UNIT PERFORMANCE and WEIGHT 30RB0372-_OPT_002B 18265
* to check wit h latest Ecat 30RB0402-_OPT_002B 18265
30RB0432-_OPT_002B 21310
OPTION 2B IS NOT SUITABLE WITH MCHX COILS 30RB0462-_OPT_002B 21310
Standard Cu/Al coils are included with option 2B 30RB0522-_OPT_002B 24355
30RB0602-_OPT_002B 27398
30RB0672-_OPT_002B 30443
30RB0732-_OPT_002B 33487
30RB0802-_OPT_002B 36531
3A Precoated "GOLD FINS" on Cu/AlCondenser coils
Fins made of pretreated aluminium 30RB0262-_OPT_003A 859
( Goldfin: polyurethane and epoxy coatings). 30RB0302-_OPT_003A 1073
Recommended for urbain and light marine applications 30RB0342-_OPT_003A 1073
30RB0372-_OPT_003A 1288
OPTION 3A IS NOT SUITABLE WITH MCHX COILS 30RB0402-_OPT_003A 1288
Standard Cu/Al coils are included with option 3A 30RB0432-_OPT_003A 1502
30RB0462-_OPT_003A 1502
CAUTION 30RB0522-_OPT_003A 1718
ONLY AVAILBLEon units with option 6 Brine, or Option 50 30RB0602-_OPT_003A 1932
Heat Recovery, or Opt 118A Direct expansion Free cooling, 30RB0672-_OPT_003A 2147
or opt 241 Storage temperature > 48C, 30RB0732-_OPT_003A 2361(All units fitted with Cu/Al coils) 30RB0802-_OPT_003A 2577
6 Brine unit for leaving brine from+3C to -10CUsing either ethylene or propylene glucol fluids, 30RB0262-_OPT_006 1567
30RB0302-_OPT_006 1734
30RB0342-_OPT_006 1935
30RB0372-_OPT_006 2019
OPTION 6 IS SUITABLE WITH MCHX COILS 30RB0402-_OPT_006 5257
CAUTION
Option 6 not compatible with option 50 and opt 118
Option 6 not compatible with combinaison of option 15LS and option 2B
Option 6 not compatible with combinaison of option 15LS and option 3A
15 Low noise levelCompressor sound enclosure: 30RB0262-_OPT_015 2178
30RB0302-_OPT_015 2784
CAUTION: 30RB0342-_OPT_015 2784
Option 15 not compatible with option 15LS 30RB0372-_OPT_015 3053
30RB0402-_OPT_015 3053
30RB0432-_OPT_015 3381
30RB0462-_OPT_015 3381
30RB0522-_OPT_015 3679
30RB0602-_OPT_015 453830RB0672-_OPT_015 4840
30RB0732-_OPT_015 4820
30RB0802-_OPT_015 5471
15LS Super low noise levelCompressor sound enclosure and low-speed fans: 30RB0262-_OPT_015LS 2295
30RB0302-_OPT_015LS 2981
30RB0342-_OPT_015LS 2982
30RB0372 OPT 015LS 3264
Brine option is not available for 30RB432 to 802 units (see Product Bulletin 025/2006-76)
Reinforced thermal insulation; compressor suction line and
evaporator.
Factory-application of Blygold Polual treatment on the coils;
recommended for marine, urban, industrial & rural
environments
-
8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008
6/13
Section :
30RB
Carrier SCS - France 262 to 802
Carrier Commercial Systems
2008 LIST PRICES
Option Description Used on Option code List price
20A IP54 Electrical Box protection 30RB0262-_OPT_020A 2189
30RB0302-_OPT_020A 2668Recommended for dusty or sandy environments 30RB0342-_OPT_020A 2668
30RB0372-_OPT_020A 2668
CAUTION 30RB0402-_OPT_020A 2668
30RB0432-_OPT_020A 2668
30RB0462-_OPT_020A 2668
Therefore when ordering option 20A, please make sure 30RB0522-_OPT_020A 2668
to also order option 15 Low Noise or option 15LS Super 30RB0602-_OPT_020A 4380
Low noise or option , 30RB0672-_OPT_020A 4380
30RB0732-_OPT_020A 4380
30RB0802-_OPT_020A 4380
23 Grilles + Side panels30RB0262-_OPT_023 2553
Side panels on coil ends and metallic grilles on the four 30RB0302-_OPT_023 3608
unit faces. 30RB0342-_OPT_023 3608
30RB0372-_OPT_023 3608
30RB0402-_OPT_023 3608
30RB0432-_OPT_023 4563
30RB0462-_OPT_023 4563
30RB0522-_OPT_023 4563
30RB0602-_OPT_023 5549
30RB0672-_OPT_023 5549
30RB0732-_OPT_023 6570
30RB0802-_OPT_023 6570
23A Side panelsSide panels on right and left coil ends. 30RB0262-_OPT_023A 44830RB0302-_OPT_023A 630
CAUTION 30RB0342-_OPT_023A 630
Option 23A not compatible with option 23 30RB0372-_OPT_023A 630
30RB0402-_OPT_023A 630
OPTION 23A IS NOT SUITABLE WITH MCHX COILS 30RB0432-_OPT_023A 818
30RB0462-_OPT_023A 818
30RB0522-_OPT_023A 818
30RB0602-_OPT_023A 1001
30RB0672-_OPT_023A 1001
30RB0732-_OPT_023A 1188
30RB0802-_OPT_023A 1188
25 Compressor Soft Starter(400/3/50) 30RB0262-_OPT_025 5694
30RB0302-_OPT_025 6592
30RB0342-_OPT_025 7011
Built with electronic soft starter on each compressor 30RB0372-_OPT_025 8011
30RB0402-_OPT_025 8415
30RB0432-_OPT_025 9780
30RB0462-_OPT_025 10184
30RB0522-_OPT_025 11952
28 Winter operation for OAT down to -20C
30RB0262-_OPT_028 474330RB0302-_OPT_028 5479
30RB0342-_OPT_028 5479
30RB0372-_OPT_028 5479
30RB0402-_OPT_028 5479
30RB0432-_OPT_028 5479
30RB0462-_OPT_028 5479
30RB0522-_OPT_028 5479
(see Product Bulletin 025/2006-76) 30RB0602-_OPT_028 8218
30RB0672- OPT 028 8218
COMPRESSOR INCLOSURE IS MANDATORY FOR THIS OPTION
CAUTIONoption 23A side panels included with option 23
Fan speed control by frequency inverter for stable operation
between 0 and -20C outdoor air temperature
CAUTIONnot compatible with options 12, 28B and 50
-
8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008
7/13
Section :
30RB
Carrier SCS - France 262 to 802
Carrier Commercial Systems
2008 LIST PRICES
Option Description Used on Option code List price
41 Evaporator frost protection 30RB0262-_OPT_041 304
Electric resistance heater on the evaporator 30RB0302-_OPT_041 30430RB0342-_OPT_041 304
30RB0372-_OPT_041 304
30RB0402-_OPT_041 304
30RB0432-_OPT_041 304
30RB0462-_OPT_041 304
30RB0522-_OPT_041 304
30RB0602-_OPT_041 304
30RB0672-_OPT_041 304
30RB0732-_OPT_041 304
30RB0802-_OPT_041 304
49 Partial heat recovery 30RB0262-_OPT_049 10911Consit of one desuperheater (plate heat exchanger) per 30RB0302-_OPT_049 12751
refrigerant circuit to recover approximtely 20% of the heat 30RB0342-_OPT_049 12810
rejected and generate hot water up to 80C. 30RB0372-_OPT_049 14229
(See PCB selection software for detailed performances) 30RB0402-_OPT_049 14246
30RB0432-_OPT_049 15790
Nota: Desuperheater interconnecting water pipe, thermal 30RB0462-_OPT_049 15781
insulation & antifreeze protection must be done on site, 30RB0522-_OPT_049 17033
30RB0602-_OPT_049 21299
OPTION 49 IS SUITABLE WITH MCHX COILS 30RB0672-_OPT_049 22631
30RB0732-_OPT_049 23564
CAUTION: not compatible with options 6, 50 and 118A. 30RB0802-_OPT_049 24896
50 Heat recovery
Heat recovery water cooled condenser to recover 100% of 30RB0262-_OPT_050 27240
the rejected heat 30RB0302-_OPT_050 30168
Minimum entering water temperature : 20C 30RB0342-_OPT_050 30143
Maximum leaving water temperature: 55C 30RB0372-_OPT_050 32232
30RB0402-_OPT_050 33092
OPTION 50 IS NOT SUITABLE WITH MCHX COILS 30RB0432-_OPT_050 34703
Standard Cu/Al coils are included with option 50 30RB0462-_OPT_050 35593
30RB0522-_OPT_050 38612
Option 50 not compatible with option 6, 58 and option 28 or 28A (see Product Bulletin 022/2006-76)
58 Duplexing 30RB0262-_OPT_058 20430RB0302-_OPT_058 204
30RB0342-_OPT_058 204
30RB0372-_OPT_058 204
30RB0402-_OPT_058 204
30RB0432-_OPT_058 204
30RB0462-_OPT_058 204
30RB0522-_OPT_058 204
30RB0602-_OPT_058 204
30RB0672-_OPT_058 204
30RB0732-_OPT_058 204
30RB0802-_OPT_058 204
70 General di sconnect switch wi thout fuse30RB0262-_OPT_070 215
30RB0302-_OPT_070 246
30RB0342-_OPT_070 246
30RB0372-_OPT_070 256
30RB0402-_OPT_070 256
30RB0432-_OPT_070 469
30RB0462 OPT 070 469
CAUTION : not compatible with the hydronic module options
116B / C / F / G , option 88A and option 118A
General electric disconnect switch factory-installed in the
control box (Two swiches on 30RB602 to 802)
CAUTION both units must be equipped with option 58, option
not compatible with option 50 heat recovery.
Unit delivered with an additional leaving water sensor to be
field installed for lead lag control of two units piped in
parallel.
-
8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008
8/13
Section :
30RB
Carrier SCS - France 262 to 802
Carrier Commercial Systems
2008 LIST PRICES
Option Description Used on Option code List price
88 Evaporator with aluminium cladding30RB0262-_OPT_088 1821
30RB0302-_OPT_088 1821
30RB0342-_OPT_088 1880
30RB0372-_OPT_088 1880
30RB0402-_OPT_088 1880
30RB0432-_OPT_088 1880
30RB0462-_OPT_088 1880
30RB0522-_OPT_088 1880
30RB0602-_OPT_088 2481
30RB0672-_OPT_088 2481
30RB0732-_OPT_088 2481
30RB0802-_OPT_088 2481
88A Evaporator and hydronic module with aluminium enclosure30RB0262-_OPT_088A 4152
30RB0302-_OPT_088A 4152
30RB0342-_OPT_088A 4211
30RB0372-_OPT_088A 4211
Option 88A not compatible with option 50 and option 88 30RB0402-_OPT_088A 4211
30RB0432-_OPT_088A 4211
Not compatible with option 116G for 30RB0262 unit 30RB0462-_OPT_088A 4211
30RB0522-_OPT_088A 4211
92 Suction valve30RB0262-_OPT_092 697
30RB0302-_OPT_092 79330RB0342-_OPT_092 870
30RB0372-_OPT_092 1041
30RB0402-_OPT_092 1041
30RB0432-_OPT_092 1041
30RB0462-_OPT_092 1041
30RB0522-_OPT_092 1041
30RB0602-_OPT_092 1562
30RB0672-_OPT_092 1562
30RB0732-_OPT_092 156230RB0802-_OPT_092 1562
116B Hydronic module with high -pressure single pump30RB0262-_OPT_116B 9224
30RB0302-_OPT_116B 9770
30RB0342-_OPT_116B 9770
30RB0372-_OPT_116B 10235
CAUTIONnot compatible with option 50 and option 88 30RB0402-_OPT_116B 10235
30RB0432-_OPT_116B 11068
30RB0462-_OPT_116B 11967
30RB0522-_OPT_116B 11967
116C30RB0262-_OPT_116C 11159
30RB0302-_OPT_116C 12310
30RB0342-_OPT_116C 1231030RB0372-_OPT_116C 13017
30RB0402-_OPT_116C 13017
30RB0432-_OPT_116C 13851
CAUTIONnot compatible with option 50 and option 88 30RB0462-_OPT_116C 15831
30RB0522-_OPT_116C 15831
116F
CAUTIONoption not compatible with option 116B/C/F/G
hydronic module, please use 88A
Automatic change-over and running time equalization
Includes water strainer, pump, closed expansion tank, throttle
valve, relief valve, gauge and freeze protection down to -20C
Hydronic module with low-pressure single pump
Shut-off valve per circuit on the compressor suction piping
Evaporator and hydronic module thermal insulation with
aluminium cladding finish for better protection
CAUTIONoption 116B/C/F/G hydronic module must be
ordered at the same time
Evaporator thermal insulation with aluminium cladding finish
for better protection
Includes water strainer, pump, closed expansion tank, throttle
valve, relief valve, gauge and freeze protection down to -20C
Hydronic module with high -pressure dual pump
-
8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008
9/13
Section :
30RB
Carrier SCS - France 262 to 802
Carrier Commercial Systems
2008 LIST PRICES
Option Description Used on Option code List price
118A Direct expansion Free Cooling30RB0262-_OPT_118A 17665
30RB0302-_OPT_118A 19176
30RB0342-_OPT_118A 20301
30RB0372-_OPT_118A 21909
30RB0402-_OPT_118A 22822
30RB0432-_OPT_118A 23606
30RB0462-_OPT_118A 24281
30RB0522-_OPT_118A 25263Option consists of compressor suction bypass valve, liquid
refrigerant pumps and the appropriate control software to
manage the automatic change over between compressor and
freecooling operating modes
OPTION 118A IS NOT SUITABLE WITH MCHX COILS
Standard Cu/Al coils are included with option 118A
IMPORTANT:do not forget to order option 28 or 28A winter operation if compressor operation is needed below 0 ambient
CAUTIONnot compatible with options 6 ( brine ), 15LS (super low noise) and 50 (Heat Recovery)
148B CCN to J-Bus gateway30RB0262-_OPT_148B 1128
30RB0302-_OPT_148B 1128
30RB0342-_OPT_148B 1128
30RB0372-_OPT_148B 112830RB0402-_OPT_148B 1128
30RB0432-_OPT_148B 1128
30RB0462-_OPT_148B 1128
30RB0522-_OPT_148B 1128
30RB0602-_OPT_148B 1128
30RB0672-_OPT_148B 1128
30RB0732-_OPT_148B 1128
30RB0802-_OPT_148B 1128
148C CCN to BacNet gateway
Two way protocol converter board between CCN and BacNetfor easy connection to BMS. Also available as an accessory 30RB0262-_OPT_148C 1129
30RB0302-_OPT_148C 1129
30RB0342-_OPT_148C 1097
30RB0372-_OPT_148C 1129
30RB0402-_OPT_148C 1129
30RB0432-_OPT_148C 1129
30RB0462-_OPT_148C 1129
30RB0522-_OPT_148C 1129
30RB0602-_OPT_148C 1129
30RB0672-_OPT_148C 1129
30RB0732-_OPT_148C 1129
30RB0802-_OPT_148C 1129
148D CCN to LonTalk gateway30RB0262-_OPT_148D 1129
30RB0302-_OPT_148D 1128
30RB0342-_OPT_148D 1128
30RB0372-_OPT_148D 1128
30RB0402-_OPT_148D 1128
30RB0432-_OPT_148D 1128
30RB0462-_OPT_148D 1128
Two way protocol converter board between CCN and Lon
Talk for easy connection to BMS. Also available as an
accessory
Cooling effect is achieved by natural migration of refrigerant
vapors from the evaporator to the condenser coils and forced
circulation of liquid refrigerant back to the evaporator
Two way protocol converter board between CCN and J-Busfor easy connection to BMS. Also available as an accesory
This option permits the generation of chilled water without
operat ing the compressors as soon as the temperature
difference LWT set point - OAT is greater than 6K
-
8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008
10/13
Section :
30RB
Carrier SCS - France 262 to 802
Carrier Commercial Systems
2008 LIST PRICES
Option Description Used on Option code List price
200 Compliance with Australian regulation30RB0262-_OPT_200 324
Temporary opt ion; 30RB0302-_OPT_200 324
with safety valves according to Australian code 30RB0342-_OPT_200 324
30RB0372-_OPT_200 324
30RB0402-_OPT_200 324
30RB0432-_OPT_200 324
30RB0462-_OPT_200 324
30RB0522-_OPT_200 324
30RB0602-_OPT_200 834
30RB0672-_OPT_200 834
30RB0732-_OPT_200 834
30RB0802-_OPT_200 834
221 Euro Pack
NO LONGER AVAILLABL E
See Bull etin 19007-78
From 10 Dec 2007
241 Storage temperature above 48C30RB0262-_OPT_241 391
30RB0302-_OPT_241 391
30RB0342-_OPT_241 39130RB0372-_OPT_241 391
CAUTIONmandatory for shipment by dry container 30RB0402-_OPT_241 391
30RB0432-_OPT_241 391
30RB0462-_OPT_241 391
30RB0522-_OPT_241 391
30RB0602-_OPT_241 589
30RB0672-_OPT_241 589
30RB0732-_OPT_241 589
30RB0802-_OPT_241 589
OPTION 241 IS NOT SUITABLE WITH MCHX COILS
Standard Cu/Al coils are included with option 241
Note Option will be modified as soon as we get final requirements
CAUTIONEuro Pack option not available with options 15,
15LS, 23, 23A, 41, 70, 70D
This option contains the options: 23A side panels, 41
evaporator frost protection, 70 general disconnect switch
without fuse and 15 low noise level
Storage of refrigerant charge in the condenser section to
avoid refrigerant release during transportation and storage.
List Prices will be adjusted to these final design modification.
-
8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008
11/13
Section :
30RB
Carrier SCS - France 262 to 802
Carrier Commercial Systems
2008 LIST PRICES
Option Description Used on Option code List price
OPT_SEI_2B Open base wooden skid All 30RB0262-_OPT_SEI_2B 1643
Open top cap 30RB0302-_OPT_SEI_2B 2168
Shrink flexible film 30RB0342-_OPT_SEI_2B 2168
30RB0372-_OPT_SEI_2B 2168
30RB0402-_OPT_SEI_2B 2168
30RB0432-_OPT_SEI_2B 2704
30RB0462-_OPT_SEI_2B 2704
30RB0522-_OPT_SEI_2B 2704
30RB0602-_OPT_SEI_2B 3246
30RB0672-_OPT_SEI_2B 324630RB0732-_OPT_SEI_2B 3787
30RB0802-_OPT_SEI_2B 3787
OPT_SEI 3 LIGHT Wooden skid All 30RB0262-_OPT_SEI_3LI 1883
Slated crate 70% open 30RB0302-_OPT_SEI_3LI 2476
Water cooled chillers will be protected with plastic wrap 30RB0342-_OPT_SEI_3LI 2476
Air cooled chillers will NOT be protected with plastic wrap (optional) 30RB0372-_OPT_SEI_3LI 247630RB0402-_OPT_SEI_3LI 2476
30RB0432-_OPT_SEI_3LI 3055
30RB0462-_OPT_SEI_3LI 305530RB0522-_OPT_SEI_3LI 3055
30RB0602-_OPT_SEI_3LI 3634
30RB0672-_OPT_SEI_3LI 3634
30RB0732-_OPT_SEI_3LI 4213
30RB0802-_OPT_SEI_3LI 4213
OPT_SEI_3 Wooden skid All 30RB0262-_OPT_SEI_3 2743
Slated crate 50% open 30RB0302-_OPT_SEI_3 3608
Water cooled chillers will be protected with plastic wrap 30RB0342-_OPT_SEI_3 3608
Air cooled chillers will NOT be protected with plastic wrap (optional)30RB0372-_OPT_SEI_3 3608
30RB0402-_OPT_SEI_3 360830RB0432-_OPT_SEI_3 4452
30RB0462-_OPT_SEI_3 4452
30RB0522-_OPT_SEI_3 4452
30RB0602-_OPT_SEI_3 5296
30RB0672-_OPT_SEI_3 5296
30RB0732-_OPT_SEI_3 6140
30RB0802-_OPT_SEI_3 6140
OPT_SEI_4 Full wooden skid All 30RB0262-_OPT_SEI_4 3237
Full plywood box 30RB0302-_OPT_SEI_4 4271
30RB0342-_OPT_SEI_4 427130RB0372-_OPT_SEI_4 4271
30RB0402-_OPT_SEI_4 4271
30RB0432-_OPT_SEI_4 5279
30RB0462-_OPT_SEI_4 5279
30RB0522-_OPT_SEI_4 5279
30RB0602-_OPT_SEI_4 6285
30RB0672-_OPT_SEI_4 6285
30RB0732-_OPT_SEI_4 7293
30RB0802 OPT SEI 4 7293
EXPORT CRATING
-
8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008
12/13
Section :
30RB
Carrier SCS - France 262 to 802
Carrier Commercial Systems
2008 LIST PRICES
Option Description Used on Option code List price
OPT_SEI_4C Full wooden skid All 30RB0262-_OPT_SEI_4C 4463
Full plywood box 30RB0302-_OPT_SEI_4C 5764
Shrink wrap 30RB0342-_OPT_SEI_4C 5764
30RB0372-_OPT_SEI_4C 5764
30RB0402-_OPT_SEI_4C 5764
30RB0432-_OPT_SEI_4C 7124
30RB0462-_OPT_SEI_4C 7124
30RB0522-_OPT_SEI_4C 7124
30RB0602-_OPT_SEI_4C 8483
30RB0672-_OPT_SEI_4C 8483
30RB0732-_OPT_SEI_4C 9842
30RB0802-_OPT_SEI_4C 9842
OPT_SKID Packing specially designed for 40 high cube loading All 30RB0262-_OPT_SKID 1381
Stuffing into container at Marseille Port, France only 30RB0302-_OPT_SKID 158130RB0342-_OPT_SKID 1581
30RB0372-_OPT_SKID 1581
30RB0402-_OPT_SKID 1581
30RB0432-_OPT_SKID 203630RB0462-_OPT_SKID 2036
30RB0522-_OPT_SKID 2036
30RB0602-_OPT_SKID 2486
30RB0672-_OPT_SKID 2486
30RB0732-_OPT_SKID 3181
30RB0802-_OPT_SKID 3181
EXPORT CRATING
-
8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008
13/13
30RB C/0 Units Options 2B 3A 6 12 15 15 LS 23 23 A 25 28 28B 41 42A 49 50 58 70 70 D 88 88A 92 92A 116 B 116 C 116 F 116 G 118A 148 B 148 C 148 D 156 196 200 241
MCH
Xcoils(standard)
MCHX coils (standard)
2B Coil with post coating treatment (Blygold Polual)
3A Coil with pre treated aluminium fins (Goldfin)
6Brine
Only on units up to 30RB0402
12 High Static Fan
15 Low noise : compressor enclosure
15 LS Super low noise : compressor enclosure & low speed fan (750 rpm)
23 Protection grilles + V panels
23 A Coil lateral V panels
25Compressor Soft Starter
Only on units up to 30RB0522
28 Low ambient kit for winter operation (0 to -20C OAT)
28B Low ambient kit for winter operation (0 to -10C OAT)
41 Cooler freeze protection (electric heater)
42ACooler + Hydronic Module freeze protection (electric heaters)
Only on units up to 30RB0262
49 Partial heat recovery
50100 % heat recovery condenser
Only on units fr om 30RB0262 to 30RB0522
58 Duplexing?
70Non fused disconnect switch
Only on units fr om 30RB0302 to 30RB0802
70 D Fused disconnect switchOnly on units fr om 30RB0302 to 30RB0802
88Cooler aluminium jacket
Only on units up to 30RB0522
88ACooler + Hydronic module aluminium jacket
Only on units fr om 30RB0302 to 30RB0522
92Suction service valve per circuit
Only on units fr om 30RB0302 to 30RB0802
92ASuction and discharge service valves per circuit
Only on units up to 30RB0262
116 BHigh pressure hydronic kit with single pump (freeze protection included)
Only on units up to 30RB0522
116 CHigh pressure hydronic kit with twin pump (freeze protection included)
Only on units up to 30RB0522
116 FLow pressure hydronic kit with single pump (freeze protection included)
Only on units up to 30RB0522
116 GLow pressure hydronic kit with twin pump (freeze protection included)
Only on units up to 30RB0522
118ADirect expansion / Free Cooling
Only on units fr om 30RB0262 to 30RB0522
148 B CCN to J-Bus gateway
148 C CCN to Bacnet gateway
148 D CCN to Lon gateway
156 Energy Management Module
196 Sealed valve
200 Compliance with Australan regulation
241 Storage temperature above 48C
Legend not compatible
compatible
Coilwithpostcoatingtreatment(BlygoldPolual)
Coilwithpretreatedalu
miniumf
ins(Goldfin)
Brine
Onlyonunitsupto30RB0402
HighStaticFan
Lownoise:compressorenclosure
Superlownoise:compressorenclosure&lowspeedfan(750rpm)
Protectiongrilles+Vpanels
C
oillateralVpanels
CompressorSoftStarterOnlyonunitsupto30RB0522
Lowambientkitforwinteroperation(0to-20COAT)
Lowambientkitforwinteroperation(0to-10COAT)
Coolerfreezeprotection(electricheater)
Cooler+HydronicModule
freezeprotection(electricheaters)Onlyonunitsup
to30RB0262
Partialheatrecovery
100%heatrecoverycondenserOn
lyonunitsfrom3
0RB0262to30RB0522
Duplexing
Nonfuseddisconnectswitch
Onlyonunitsfrom3
0RB0302to30RB0802
Fuseddisconnectswitch
Onlyonunitsfrom3
0RB0
302to30RB0802
CooleraluminiumjacketOnlyonunitsupto30RB0522
Cooler+HydronicmodulealuminiumjacketOnlyonunitsfrom3
0RB0302to30RB0522
SuctionservicevalvepercircuitOnlyonunitsfrom3
0RB0302to3
0RB0802
Suctionanddischargeservicevalvespercircuit
Onlyonunitsupto30RB0262
Highpressurehydronick
itwithsinglepump(freezeprotectionincluded)Only
onunitsupto30RB0522
Highpressurehydronickitwithtwinpump(freezeprotectionincluded)Onlyonunitsupto30RB0522
Lowpressurehydronickitwithsing
lepump(freezeprotectionincluded)Onlyonunitsu
pto30RB0522
Lowpressurehydronickitwithtwinpump(freezeprotectionincluded)Onlyonunitsupto30
RB0522
Directexpansion/FreeCooling
Onlyonunitsfrom3
0RB0262to30RB0522
CCNtoJ-Busgateway
CompliancewithAustralanregulation
Storagetemperatureabove
48C
CC
NtoBacnetgateway
CCNto
Longateway
EnergyManagementModule
Sealedvalve
Supersedes :January 04 th, 2008
Product sourcing :
CARRIER SCS
BP 49 - 01122 MONTLUEL Cedex - France
----------------------------------------------
Page No 13/13 Effective Date : June 01 st, 2008