    Carrier SCS - France 262 to 802

    R410A

    Carrier Commercial Systems

    2008 LIST PRICES

    30RB AIR COOLED CHILLERS

    30RB with Option 15

    Standard unit delivered with MCHXCoils

  • 8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008

    2/13

    Section :

    30RB

    Carrier SCS - France 262 to 802

    Carrier Commercial Systems

    2008 LIST PRICES

    These air-cooled packaged chiller units are fully piped and charged with refrigerant HFC-410A.Weatherproof construction, lightweight distribution and small footprint make them ideal for rooftop or ground level installation.

    Upward discharge airflow minimizes directional sound and carries heat away from surrounding areas.

    30RB 30RB

    262-522 602-802

    Full Load Factory Run Test Std Std

    Compressors

    Rotary Scroll Compressors Std Std

    Rubber Vibration Isolators Std Std

    Across-the-line start Std Std

    Compressor Discharge Shutoff Valves per circuit Std Std

    Compressor Over temperature Protection (Scroll Protection Module) Std Std

    Patented Compressor Anti-Short Cycling Protection Std StdCompressor sound enclosure (note 1) OPT OPT

    Crankcase heaters Std Std

    Refrigeration circui t

    R-410A Refrigerant Charge Std Std

    Independent Refrigeration Circuits Std Std

    Long-Stroke Electronic Expansion Valve (EXV) Std Std

    Moisture Indicating Sight Glass Std Std

    High Pressure safety protection by compressor Std Std

    Low Pressure Protection Std Std

    Filter drier with removeable core Std Std

    Manual liquid line shut off valve Std Std

    Cooler

    Cooler Heater (note 1) OPT OPTCooler Insulation Std Std

    Chilled Water Flow Switch Std Std

    Low Water Temp Protection Std Std

    Safety relief valve Std Std

    Condenser

    Micro-channel heat exchanger (MCHX) Std Std

    Blygold Polual -Coating with traditonnal Cu/Al Condenser Coils (note 2) OPT OPT

    Flying Bird IV Low Noise Fans Std Std

    Power and Control electrical boxSingle Point Power Entry Std NA

    Unit Mounted Non Fused Main Disconnect (note 1) OPT OPT

    Hinged Access doors Std Std

    24 Volts Control Transformer Std StdControl Display Access Door Std Std

    Safeties and Controls

    Pro-Dialog control and display Std Std

    Two units Automatic Lead/Lag OPT OPT

    Temperature & Pressure Display Std Std

    Chilled Water Temperature Reset based on Outdoor Air Temperature Std Std

    One step Demand Limit Control Std Std

    On/Off Chilled water pump control Std Std

    Dual set point Std Std

    RS 485 CCN port Std Std

    Frame and casing

    Base rail with anti corrosion protection Std Std

    RAL 7035 paint finish on chassis and casing Std StdCoil end side panel (note 1) note 1 note 1

    Compressor / Condenser Coils Grilles OPT OPT

    Std Standard Feature

    OPT Factory-Installed Option

    Accy Field-Installed Accessory

    N/A Not Available

    30RB AIR COOLED CHILLERS

    Note 1 :

    MAJOR FEATURES

  • 8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008

    3/13

    Section :

    30RB

    Carrier SCS - France 262 to 802

    Carrier Commercial Systems

    2008 LIST PRICES

    Digit number

    Product code

    Legend Digits 1 to 3: liquid chiller with rotary scroll compressors

    Digit 4: model series, B air cooled cooling only, Q air to water heat pump

    Digits 5 to 8: model number based on cooling capacity in kW

    Digit 9: not used

    Digit 10: index for major product modification (visible impact for customer)

    Digit 11 to 14: counter used to generate an one time product code

    Digit 15: not used

    Digit 16: Country code / P with Montluel 30RB (European PED pressure vessel approval)

    Digit 17 & 18, always EE (Montluel production)

    List Price in Euros without Europack

    Product code List Price

    30RB0262- 93 186

    30RB0302- 103 144

    30RB0342- 113 001

    30RB0372- 123 116 30RB0402- 132 024

    30RB0432- 138 291

    30RB0462- 145 816

    30RB0522- 160 035

    30RB0602- 182 823

    30RB0672- 196 102

    30RB0732- 209 261

    30RB0802- 222 546

    EEP-1000--2620BR03

    181716151413121110987654321

  • 8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008

    4/13

    Section :

    30RB

    Carrier SCS - France 262 to 802

    Carrier Commercial Systems

    2008 LIST PRICES

    Accesso ry code Description Used on List price

    00PSG000119100A----- CCN to J-Bus gateway ALL 1 149

    Two way protocol converter board between CCN and J-Bus

    for easy connection to BMS. To be field installed in the chiller

    electrical box. Also available as an option

    00PSG000119200A----- CCN to BacNet gateway ALL 1 149

    Two way protocol converter board between CCN and BacNet

    for easy connection to BMS. To be field installed in the chiller

    electrical box. Also available as an option

    00PSG000119300A----- CCN to LonTalk gateway ALL 1 149Two way protocol converter board between CCN and Lon

    Talk for easy connection to BMS. To be field installed in the

    chiller electrical box. Also available as an option

    00PSG000119400A----- Energy management module EMM ALL 1 629Provides additional contacts for: Temperature reset (space

    temperature and 4-20 mA).Capacity control (4-20mA and 3

    steps). Occupancy overide, Chiller capacity, Compressor

    running output. Also available as an option00PSG000119500A----- Scrolling Marquee remote user interface ALL 2 069

    Remote diplay module for access to unit status, operation,

    configuration and troubleshooting diagnostics. Maximum 300

    m distance from chiller, needs 230-1-50 power supply

    00PSG000119601A----- Victaulic connection s leeve. Diameter 4" (*) 1 048

    00PSG000119602A----- Victaulic connection s leeve. Diameter 5" (*) 857

    00PSG000119603A----- Victaulic connection s leeve. Diameter 6" (*) 1 026(*) Evaporator connecting pipe delivered with a Victaulic

    coupling. Can be welded or threaded on site

    CAUTION30RB with/without hydro module have different

    water connection diameter Please check your connection

    diameter before ordering

    00PSG000119701A----- Power electric box extension (**) 30RB0302 to 402 776

    00PSG000119702A----- Power electric box extension (**) 30RB0432 to 522 858

    00PSG000119703A-----Power electric box extension (**) 2

    pieces 30RB0602 to 672 1 547

    00PSG000119704A-----Power electric box extension (**) 2

    pieces 30RB0732 to 802 1 629

    (**) Used to facilitate connection of big size power cable with

    large bending radius. Only stripped wires will enter the unit

    power box

    00PSG000120000A----- Boiler control board ALL 1 058

    Used for boiler ON/OFF control. (Aquasmart system) or

    electric heater 4 stage control (30RQ Heat pump). To be

    installed remotely, needs 400-3-50 power supply

    Prodialog Service Simulator A P 30RB

    ACCESSORIES - FIELD INSTALLEDNA : Not Available

  • 8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008

    5/13

    Section :

    30RB

    Carrier SCS - France 262 to 802

    Carrier Commercial Systems

    2008 LIST PRICES

    Option Description Used on Option code List price

    2B Condenser with anti-corrosion post-treatment30RB0262-_OPT_002B 12177

    30RB0302-_OPT_002B 15221

    30RB0342-_OPT_002B 15221

    CAUTION : NEW UNIT PERFORMANCE and WEIGHT 30RB0372-_OPT_002B 18265

    * to check wit h latest Ecat 30RB0402-_OPT_002B 18265

    30RB0432-_OPT_002B 21310

    OPTION 2B IS NOT SUITABLE WITH MCHX COILS 30RB0462-_OPT_002B 21310

    Standard Cu/Al coils are included with option 2B 30RB0522-_OPT_002B 24355

    30RB0602-_OPT_002B 27398

    30RB0672-_OPT_002B 30443

    30RB0732-_OPT_002B 33487

    30RB0802-_OPT_002B 36531

    3A Precoated "GOLD FINS" on Cu/AlCondenser coils

    Fins made of pretreated aluminium 30RB0262-_OPT_003A 859

    ( Goldfin: polyurethane and epoxy coatings). 30RB0302-_OPT_003A 1073

    Recommended for urbain and light marine applications 30RB0342-_OPT_003A 1073

    30RB0372-_OPT_003A 1288

    OPTION 3A IS NOT SUITABLE WITH MCHX COILS 30RB0402-_OPT_003A 1288

    Standard Cu/Al coils are included with option 3A 30RB0432-_OPT_003A 1502

    30RB0462-_OPT_003A 1502

    CAUTION 30RB0522-_OPT_003A 1718

    ONLY AVAILBLEon units with option 6 Brine, or Option 50 30RB0602-_OPT_003A 1932

    Heat Recovery, or Opt 118A Direct expansion Free cooling, 30RB0672-_OPT_003A 2147

    or opt 241 Storage temperature > 48C, 30RB0732-_OPT_003A 2361(All units fitted with Cu/Al coils) 30RB0802-_OPT_003A 2577

    6 Brine unit for leaving brine from+3C to -10CUsing either ethylene or propylene glucol fluids, 30RB0262-_OPT_006 1567

    30RB0302-_OPT_006 1734

    30RB0342-_OPT_006 1935

    30RB0372-_OPT_006 2019

    OPTION 6 IS SUITABLE WITH MCHX COILS 30RB0402-_OPT_006 5257

    CAUTION

    Option 6 not compatible with option 50 and opt 118

    Option 6 not compatible with combinaison of option 15LS and option 2B

    Option 6 not compatible with combinaison of option 15LS and option 3A

    15 Low noise levelCompressor sound enclosure: 30RB0262-_OPT_015 2178

    30RB0302-_OPT_015 2784

    CAUTION: 30RB0342-_OPT_015 2784

    Option 15 not compatible with option 15LS 30RB0372-_OPT_015 3053

    30RB0402-_OPT_015 3053

    30RB0432-_OPT_015 3381

    30RB0462-_OPT_015 3381

    30RB0522-_OPT_015 3679

    30RB0602-_OPT_015 453830RB0672-_OPT_015 4840

    30RB0732-_OPT_015 4820

    30RB0802-_OPT_015 5471

    15LS Super low noise levelCompressor sound enclosure and low-speed fans: 30RB0262-_OPT_015LS 2295

    30RB0302-_OPT_015LS 2981

    30RB0342-_OPT_015LS 2982

    30RB0372 OPT 015LS 3264

    Brine option is not available for 30RB432 to 802 units (see Product Bulletin 025/2006-76)

    Reinforced thermal insulation; compressor suction line and

    evaporator.

    Factory-application of Blygold Polual treatment on the coils;

    recommended for marine, urban, industrial & rural

    environments

  • 8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008

    6/13

    Section :

    30RB

    Carrier SCS - France 262 to 802

    Carrier Commercial Systems

    2008 LIST PRICES

    Option Description Used on Option code List price

    20A IP54 Electrical Box protection 30RB0262-_OPT_020A 2189

    30RB0302-_OPT_020A 2668Recommended for dusty or sandy environments 30RB0342-_OPT_020A 2668

    30RB0372-_OPT_020A 2668

    CAUTION 30RB0402-_OPT_020A 2668

    30RB0432-_OPT_020A 2668

    30RB0462-_OPT_020A 2668

    Therefore when ordering option 20A, please make sure 30RB0522-_OPT_020A 2668

    to also order option 15 Low Noise or option 15LS Super 30RB0602-_OPT_020A 4380

    Low noise or option , 30RB0672-_OPT_020A 4380

    30RB0732-_OPT_020A 4380

    30RB0802-_OPT_020A 4380

    23 Grilles + Side panels30RB0262-_OPT_023 2553

    Side panels on coil ends and metallic grilles on the four 30RB0302-_OPT_023 3608

    unit faces. 30RB0342-_OPT_023 3608

    30RB0372-_OPT_023 3608

    30RB0402-_OPT_023 3608

    30RB0432-_OPT_023 4563

    30RB0462-_OPT_023 4563

    30RB0522-_OPT_023 4563

    30RB0602-_OPT_023 5549

    30RB0672-_OPT_023 5549

    30RB0732-_OPT_023 6570

    30RB0802-_OPT_023 6570

    23A Side panelsSide panels on right and left coil ends. 30RB0262-_OPT_023A 44830RB0302-_OPT_023A 630

    CAUTION 30RB0342-_OPT_023A 630

    Option 23A not compatible with option 23 30RB0372-_OPT_023A 630

    30RB0402-_OPT_023A 630

    OPTION 23A IS NOT SUITABLE WITH MCHX COILS 30RB0432-_OPT_023A 818

    30RB0462-_OPT_023A 818

    30RB0522-_OPT_023A 818

    30RB0602-_OPT_023A 1001

    30RB0672-_OPT_023A 1001

    30RB0732-_OPT_023A 1188

    30RB0802-_OPT_023A 1188

    25 Compressor Soft Starter(400/3/50) 30RB0262-_OPT_025 5694

    30RB0302-_OPT_025 6592

    30RB0342-_OPT_025 7011

    Built with electronic soft starter on each compressor 30RB0372-_OPT_025 8011

    30RB0402-_OPT_025 8415

    30RB0432-_OPT_025 9780

    30RB0462-_OPT_025 10184

    30RB0522-_OPT_025 11952

    28 Winter operation for OAT down to -20C

    30RB0262-_OPT_028 474330RB0302-_OPT_028 5479

    30RB0342-_OPT_028 5479

    30RB0372-_OPT_028 5479

    30RB0402-_OPT_028 5479

    30RB0432-_OPT_028 5479

    30RB0462-_OPT_028 5479

    30RB0522-_OPT_028 5479

    (see Product Bulletin 025/2006-76) 30RB0602-_OPT_028 8218

    30RB0672- OPT 028 8218

    COMPRESSOR INCLOSURE IS MANDATORY FOR THIS OPTION

    CAUTIONoption 23A side panels included with option 23

    Fan speed control by frequency inverter for stable operation

    between 0 and -20C outdoor air temperature

    CAUTIONnot compatible with options 12, 28B and 50

  • 8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008

    7/13

    Section :

    30RB

    Carrier SCS - France 262 to 802

    Carrier Commercial Systems

    2008 LIST PRICES

    Option Description Used on Option code List price

    41 Evaporator frost protection 30RB0262-_OPT_041 304

    Electric resistance heater on the evaporator 30RB0302-_OPT_041 30430RB0342-_OPT_041 304

    30RB0372-_OPT_041 304

    30RB0402-_OPT_041 304

    30RB0432-_OPT_041 304

    30RB0462-_OPT_041 304

    30RB0522-_OPT_041 304

    30RB0602-_OPT_041 304

    30RB0672-_OPT_041 304

    30RB0732-_OPT_041 304

    30RB0802-_OPT_041 304

    49 Partial heat recovery 30RB0262-_OPT_049 10911Consit of one desuperheater (plate heat exchanger) per 30RB0302-_OPT_049 12751

    refrigerant circuit to recover approximtely 20% of the heat 30RB0342-_OPT_049 12810

    rejected and generate hot water up to 80C. 30RB0372-_OPT_049 14229

    (See PCB selection software for detailed performances) 30RB0402-_OPT_049 14246

    30RB0432-_OPT_049 15790

    Nota: Desuperheater interconnecting water pipe, thermal 30RB0462-_OPT_049 15781

    insulation & antifreeze protection must be done on site, 30RB0522-_OPT_049 17033

    30RB0602-_OPT_049 21299

    OPTION 49 IS SUITABLE WITH MCHX COILS 30RB0672-_OPT_049 22631

    30RB0732-_OPT_049 23564

    CAUTION: not compatible with options 6, 50 and 118A. 30RB0802-_OPT_049 24896

    50 Heat recovery

    Heat recovery water cooled condenser to recover 100% of 30RB0262-_OPT_050 27240

    the rejected heat 30RB0302-_OPT_050 30168

    Minimum entering water temperature : 20C 30RB0342-_OPT_050 30143

    Maximum leaving water temperature: 55C 30RB0372-_OPT_050 32232

    30RB0402-_OPT_050 33092

    OPTION 50 IS NOT SUITABLE WITH MCHX COILS 30RB0432-_OPT_050 34703

    Standard Cu/Al coils are included with option 50 30RB0462-_OPT_050 35593

    30RB0522-_OPT_050 38612

    Option 50 not compatible with option 6, 58 and option 28 or 28A (see Product Bulletin 022/2006-76)

    58 Duplexing 30RB0262-_OPT_058 20430RB0302-_OPT_058 204

    30RB0342-_OPT_058 204

    30RB0372-_OPT_058 204

    30RB0402-_OPT_058 204

    30RB0432-_OPT_058 204

    30RB0462-_OPT_058 204

    30RB0522-_OPT_058 204

    30RB0602-_OPT_058 204

    30RB0672-_OPT_058 204

    30RB0732-_OPT_058 204

    30RB0802-_OPT_058 204

    70 General di sconnect switch wi thout fuse30RB0262-_OPT_070 215

    30RB0302-_OPT_070 246

    30RB0342-_OPT_070 246

    30RB0372-_OPT_070 256

    30RB0402-_OPT_070 256

    30RB0432-_OPT_070 469

    30RB0462 OPT 070 469

    CAUTION : not compatible with the hydronic module options

    116B / C / F / G , option 88A and option 118A

    General electric disconnect switch factory-installed in the

    control box (Two swiches on 30RB602 to 802)

    CAUTION both units must be equipped with option 58, option

    not compatible with option 50 heat recovery.

    Unit delivered with an additional leaving water sensor to be

    field installed for lead lag control of two units piped in

    parallel.

  • 8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008

    8/13

    Section :

    30RB

    Carrier SCS - France 262 to 802

    Carrier Commercial Systems

    2008 LIST PRICES

    Option Description Used on Option code List price

    88 Evaporator with aluminium cladding30RB0262-_OPT_088 1821

    30RB0302-_OPT_088 1821

    30RB0342-_OPT_088 1880

    30RB0372-_OPT_088 1880

    30RB0402-_OPT_088 1880

    30RB0432-_OPT_088 1880

    30RB0462-_OPT_088 1880

    30RB0522-_OPT_088 1880

    30RB0602-_OPT_088 2481

    30RB0672-_OPT_088 2481

    30RB0732-_OPT_088 2481

    30RB0802-_OPT_088 2481

    88A Evaporator and hydronic module with aluminium enclosure30RB0262-_OPT_088A 4152

    30RB0302-_OPT_088A 4152

    30RB0342-_OPT_088A 4211

    30RB0372-_OPT_088A 4211

    Option 88A not compatible with option 50 and option 88 30RB0402-_OPT_088A 4211

    30RB0432-_OPT_088A 4211

    Not compatible with option 116G for 30RB0262 unit 30RB0462-_OPT_088A 4211

    30RB0522-_OPT_088A 4211

    92 Suction valve30RB0262-_OPT_092 697

    30RB0302-_OPT_092 79330RB0342-_OPT_092 870

    30RB0372-_OPT_092 1041

    30RB0402-_OPT_092 1041

    30RB0432-_OPT_092 1041

    30RB0462-_OPT_092 1041

    30RB0522-_OPT_092 1041

    30RB0602-_OPT_092 1562

    30RB0672-_OPT_092 1562

    30RB0732-_OPT_092 156230RB0802-_OPT_092 1562

    116B Hydronic module with high -pressure single pump30RB0262-_OPT_116B 9224

    30RB0302-_OPT_116B 9770

    30RB0342-_OPT_116B 9770

    30RB0372-_OPT_116B 10235

    CAUTIONnot compatible with option 50 and option 88 30RB0402-_OPT_116B 10235

    30RB0432-_OPT_116B 11068

    30RB0462-_OPT_116B 11967

    30RB0522-_OPT_116B 11967

    116C30RB0262-_OPT_116C 11159

    30RB0302-_OPT_116C 12310

    30RB0342-_OPT_116C 1231030RB0372-_OPT_116C 13017

    30RB0402-_OPT_116C 13017

    30RB0432-_OPT_116C 13851

    CAUTIONnot compatible with option 50 and option 88 30RB0462-_OPT_116C 15831

    30RB0522-_OPT_116C 15831

    116F

    CAUTIONoption not compatible with option 116B/C/F/G

    hydronic module, please use 88A

    Automatic change-over and running time equalization

    Includes water strainer, pump, closed expansion tank, throttle

    valve, relief valve, gauge and freeze protection down to -20C

    Hydronic module with low-pressure single pump

    Shut-off valve per circuit on the compressor suction piping

    Evaporator and hydronic module thermal insulation with

    aluminium cladding finish for better protection

    CAUTIONoption 116B/C/F/G hydronic module must be

    ordered at the same time

    Evaporator thermal insulation with aluminium cladding finish

    for better protection

    Includes water strainer, pump, closed expansion tank, throttle

    valve, relief valve, gauge and freeze protection down to -20C

    Hydronic module with high -pressure dual pump

  • 8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008

    9/13

    Section :

    30RB

    Carrier SCS - France 262 to 802

    Carrier Commercial Systems

    2008 LIST PRICES

    Option Description Used on Option code List price

    118A Direct expansion Free Cooling30RB0262-_OPT_118A 17665

    30RB0302-_OPT_118A 19176

    30RB0342-_OPT_118A 20301

    30RB0372-_OPT_118A 21909

    30RB0402-_OPT_118A 22822

    30RB0432-_OPT_118A 23606

    30RB0462-_OPT_118A 24281

    30RB0522-_OPT_118A 25263Option consists of compressor suction bypass valve, liquid

    refrigerant pumps and the appropriate control software to

    manage the automatic change over between compressor and

    freecooling operating modes

    OPTION 118A IS NOT SUITABLE WITH MCHX COILS

    Standard Cu/Al coils are included with option 118A

    IMPORTANT:do not forget to order option 28 or 28A winter operation if compressor operation is needed below 0 ambient

    CAUTIONnot compatible with options 6 ( brine ), 15LS (super low noise) and 50 (Heat Recovery)

    148B CCN to J-Bus gateway30RB0262-_OPT_148B 1128

    30RB0302-_OPT_148B 1128

    30RB0342-_OPT_148B 1128

    30RB0372-_OPT_148B 112830RB0402-_OPT_148B 1128

    30RB0432-_OPT_148B 1128

    30RB0462-_OPT_148B 1128

    30RB0522-_OPT_148B 1128

    30RB0602-_OPT_148B 1128

    30RB0672-_OPT_148B 1128

    30RB0732-_OPT_148B 1128

    30RB0802-_OPT_148B 1128

    148C CCN to BacNet gateway

    Two way protocol converter board between CCN and BacNetfor easy connection to BMS. Also available as an accessory 30RB0262-_OPT_148C 1129

    30RB0302-_OPT_148C 1129

    30RB0342-_OPT_148C 1097

    30RB0372-_OPT_148C 1129

    30RB0402-_OPT_148C 1129

    30RB0432-_OPT_148C 1129

    30RB0462-_OPT_148C 1129

    30RB0522-_OPT_148C 1129

    30RB0602-_OPT_148C 1129

    30RB0672-_OPT_148C 1129

    30RB0732-_OPT_148C 1129

    30RB0802-_OPT_148C 1129

    148D CCN to LonTalk gateway30RB0262-_OPT_148D 1129

    30RB0302-_OPT_148D 1128

    30RB0342-_OPT_148D 1128

    30RB0372-_OPT_148D 1128

    30RB0402-_OPT_148D 1128

    30RB0432-_OPT_148D 1128

    30RB0462-_OPT_148D 1128

    Two way protocol converter board between CCN and Lon

    Talk for easy connection to BMS. Also available as an

    accessory

    Cooling effect is achieved by natural migration of refrigerant

    vapors from the evaporator to the condenser coils and forced

    circulation of liquid refrigerant back to the evaporator

    Two way protocol converter board between CCN and J-Busfor easy connection to BMS. Also available as an accesory

    This option permits the generation of chilled water without

    operat ing the compressors as soon as the temperature

    difference LWT set point - OAT is greater than 6K

  • 8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008

    10/13

    Section :

    30RB

    Carrier SCS - France 262 to 802

    Carrier Commercial Systems

    2008 LIST PRICES

    Option Description Used on Option code List price

    200 Compliance with Australian regulation30RB0262-_OPT_200 324

    Temporary opt ion; 30RB0302-_OPT_200 324

    with safety valves according to Australian code 30RB0342-_OPT_200 324

    30RB0372-_OPT_200 324

    30RB0402-_OPT_200 324

    30RB0432-_OPT_200 324

    30RB0462-_OPT_200 324

    30RB0522-_OPT_200 324

    30RB0602-_OPT_200 834

    30RB0672-_OPT_200 834

    30RB0732-_OPT_200 834

    30RB0802-_OPT_200 834

    221 Euro Pack

    NO LONGER AVAILLABL E

    See Bull etin 19007-78

    From 10 Dec 2007

    241 Storage temperature above 48C30RB0262-_OPT_241 391

    30RB0302-_OPT_241 391

    30RB0342-_OPT_241 39130RB0372-_OPT_241 391

    CAUTIONmandatory for shipment by dry container 30RB0402-_OPT_241 391

    30RB0432-_OPT_241 391

    30RB0462-_OPT_241 391

    30RB0522-_OPT_241 391

    30RB0602-_OPT_241 589

    30RB0672-_OPT_241 589

    30RB0732-_OPT_241 589

    30RB0802-_OPT_241 589

    OPTION 241 IS NOT SUITABLE WITH MCHX COILS

    Standard Cu/Al coils are included with option 241

    Note Option will be modified as soon as we get final requirements

    CAUTIONEuro Pack option not available with options 15,

    15LS, 23, 23A, 41, 70, 70D

    This option contains the options: 23A side panels, 41

    evaporator frost protection, 70 general disconnect switch

    without fuse and 15 low noise level

    Storage of refrigerant charge in the condenser section to

    avoid refrigerant release during transportation and storage.

    List Prices will be adjusted to these final design modification.

  • 8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008

    11/13

    Section :

    30RB

    Carrier SCS - France 262 to 802

    Carrier Commercial Systems

    2008 LIST PRICES

    Option Description Used on Option code List price

    OPT_SEI_2B Open base wooden skid All 30RB0262-_OPT_SEI_2B 1643

    Open top cap 30RB0302-_OPT_SEI_2B 2168

    Shrink flexible film 30RB0342-_OPT_SEI_2B 2168

    30RB0372-_OPT_SEI_2B 2168

    30RB0402-_OPT_SEI_2B 2168

    30RB0432-_OPT_SEI_2B 2704

    30RB0462-_OPT_SEI_2B 2704

    30RB0522-_OPT_SEI_2B 2704

    30RB0602-_OPT_SEI_2B 3246

    30RB0672-_OPT_SEI_2B 324630RB0732-_OPT_SEI_2B 3787

    30RB0802-_OPT_SEI_2B 3787

    OPT_SEI 3 LIGHT Wooden skid All 30RB0262-_OPT_SEI_3LI 1883

    Slated crate 70% open 30RB0302-_OPT_SEI_3LI 2476

    Water cooled chillers will be protected with plastic wrap 30RB0342-_OPT_SEI_3LI 2476

    Air cooled chillers will NOT be protected with plastic wrap (optional) 30RB0372-_OPT_SEI_3LI 247630RB0402-_OPT_SEI_3LI 2476

    30RB0432-_OPT_SEI_3LI 3055

    30RB0462-_OPT_SEI_3LI 305530RB0522-_OPT_SEI_3LI 3055

    30RB0602-_OPT_SEI_3LI 3634

    30RB0672-_OPT_SEI_3LI 3634

    30RB0732-_OPT_SEI_3LI 4213

    30RB0802-_OPT_SEI_3LI 4213

    OPT_SEI_3 Wooden skid All 30RB0262-_OPT_SEI_3 2743

    Slated crate 50% open 30RB0302-_OPT_SEI_3 3608

    Water cooled chillers will be protected with plastic wrap 30RB0342-_OPT_SEI_3 3608

    Air cooled chillers will NOT be protected with plastic wrap (optional)30RB0372-_OPT_SEI_3 3608

    30RB0402-_OPT_SEI_3 360830RB0432-_OPT_SEI_3 4452

    30RB0462-_OPT_SEI_3 4452

    30RB0522-_OPT_SEI_3 4452

    30RB0602-_OPT_SEI_3 5296

    30RB0672-_OPT_SEI_3 5296

    30RB0732-_OPT_SEI_3 6140

    30RB0802-_OPT_SEI_3 6140

    OPT_SEI_4 Full wooden skid All 30RB0262-_OPT_SEI_4 3237

    Full plywood box 30RB0302-_OPT_SEI_4 4271

    30RB0342-_OPT_SEI_4 427130RB0372-_OPT_SEI_4 4271

    30RB0402-_OPT_SEI_4 4271

    30RB0432-_OPT_SEI_4 5279

    30RB0462-_OPT_SEI_4 5279

    30RB0522-_OPT_SEI_4 5279

    30RB0602-_OPT_SEI_4 6285

    30RB0672-_OPT_SEI_4 6285

    30RB0732-_OPT_SEI_4 7293

    30RB0802 OPT SEI 4 7293

    EXPORT CRATING

  • 8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008

    12/13

    Section :

    30RB

    Carrier SCS - France 262 to 802

    Carrier Commercial Systems

    2008 LIST PRICES

    Option Description Used on Option code List price

    OPT_SEI_4C Full wooden skid All 30RB0262-_OPT_SEI_4C 4463

    Full plywood box 30RB0302-_OPT_SEI_4C 5764

    Shrink wrap 30RB0342-_OPT_SEI_4C 5764

    30RB0372-_OPT_SEI_4C 5764

    30RB0402-_OPT_SEI_4C 5764

    30RB0432-_OPT_SEI_4C 7124

    30RB0462-_OPT_SEI_4C 7124

    30RB0522-_OPT_SEI_4C 7124

    30RB0602-_OPT_SEI_4C 8483

    30RB0672-_OPT_SEI_4C 8483

    30RB0732-_OPT_SEI_4C 9842

    30RB0802-_OPT_SEI_4C 9842

    OPT_SKID Packing specially designed for 40 high cube loading All 30RB0262-_OPT_SKID 1381

    Stuffing into container at Marseille Port, France only 30RB0302-_OPT_SKID 158130RB0342-_OPT_SKID 1581

    30RB0372-_OPT_SKID 1581

    30RB0402-_OPT_SKID 1581

    30RB0432-_OPT_SKID 203630RB0462-_OPT_SKID 2036

    30RB0522-_OPT_SKID 2036

    30RB0602-_OPT_SKID 2486

    30RB0672-_OPT_SKID 2486

    30RB0732-_OPT_SKID 3181

    30RB0802-_OPT_SKID 3181

    EXPORT CRATING

  • 8/12/2019 30RB Montluel Chillers LP & POD 2008@01!06!2008

    13/13

    30RB C/0 Units Options 2B 3A 6 12 15 15 LS 23 23 A 25 28 28B 41 42A 49 50 58 70 70 D 88 88A 92 92A 116 B 116 C 116 F 116 G 118A 148 B 148 C 148 D 156 196 200 241

    MCH

    Xcoils(standard)

    MCHX coils (standard)

    2B Coil with post coating treatment (Blygold Polual)

    3A Coil with pre treated aluminium fins (Goldfin)

    6Brine

    Only on units up to 30RB0402

    12 High Static Fan

    15 Low noise : compressor enclosure

    15 LS Super low noise : compressor enclosure & low speed fan (750 rpm)

    23 Protection grilles + V panels

    23 A Coil lateral V panels

    25Compressor Soft Starter

    Only on units up to 30RB0522

    28 Low ambient kit for winter operation (0 to -20C OAT)

    28B Low ambient kit for winter operation (0 to -10C OAT)

    41 Cooler freeze protection (electric heater)

    42ACooler + Hydronic Module freeze protection (electric heaters)

    Only on units up to 30RB0262

    49 Partial heat recovery

    50100 % heat recovery condenser

    Only on units fr om 30RB0262 to 30RB0522

    58 Duplexing?

    70Non fused disconnect switch

    Only on units fr om 30RB0302 to 30RB0802

    70 D Fused disconnect switchOnly on units fr om 30RB0302 to 30RB0802

    88Cooler aluminium jacket

    Only on units up to 30RB0522

    88ACooler + Hydronic module aluminium jacket

    Only on units fr om 30RB0302 to 30RB0522

    92Suction service valve per circuit

    Only on units fr om 30RB0302 to 30RB0802

    92ASuction and discharge service valves per circuit

    Only on units up to 30RB0262

    116 BHigh pressure hydronic kit with single pump (freeze protection included)

    Only on units up to 30RB0522

    116 CHigh pressure hydronic kit with twin pump (freeze protection included)

    Only on units up to 30RB0522

    116 FLow pressure hydronic kit with single pump (freeze protection included)

    Only on units up to 30RB0522

    116 GLow pressure hydronic kit with twin pump (freeze protection included)

    Only on units up to 30RB0522

    118ADirect expansion / Free Cooling

    Only on units fr om 30RB0262 to 30RB0522

    148 B CCN to J-Bus gateway

    148 C CCN to Bacnet gateway

    148 D CCN to Lon gateway

    156 Energy Management Module

    196 Sealed valve

    200 Compliance with Australan regulation

    241 Storage temperature above 48C

    Legend not compatible

    compatible

    Coilwithpostcoatingtreatment(BlygoldPolual)

    Coilwithpretreatedalu

    miniumf

    ins(Goldfin)

    Brine

    Onlyonunitsupto30RB0402

    HighStaticFan

    Lownoise:compressorenclosure

    Superlownoise:compressorenclosure&lowspeedfan(750rpm)

    Protectiongrilles+Vpanels

    C

    oillateralVpanels

    CompressorSoftStarterOnlyonunitsupto30RB0522

    Lowambientkitforwinteroperation(0to-20COAT)

    Lowambientkitforwinteroperation(0to-10COAT)

    Coolerfreezeprotection(electricheater)

    Cooler+HydronicModule

    freezeprotection(electricheaters)Onlyonunitsup

    to30RB0262

    Partialheatrecovery

    100%heatrecoverycondenserOn

    lyonunitsfrom3

    0RB0262to30RB0522

    Duplexing

    Nonfuseddisconnectswitch

    Onlyonunitsfrom3

    0RB0302to30RB0802

    Fuseddisconnectswitch

    Onlyonunitsfrom3

    0RB0

    302to30RB0802

    CooleraluminiumjacketOnlyonunitsupto30RB0522

    Cooler+HydronicmodulealuminiumjacketOnlyonunitsfrom3

    0RB0302to30RB0522

    SuctionservicevalvepercircuitOnlyonunitsfrom3

    0RB0302to3

    0RB0802

    Suctionanddischargeservicevalvespercircuit

    Onlyonunitsupto30RB0262

    Highpressurehydronick

    itwithsinglepump(freezeprotectionincluded)Only

    onunitsupto30RB0522

    Highpressurehydronickitwithtwinpump(freezeprotectionincluded)Onlyonunitsupto30RB0522

    Lowpressurehydronickitwithsing

    lepump(freezeprotectionincluded)Onlyonunitsu

    pto30RB0522

    Lowpressurehydronickitwithtwinpump(freezeprotectionincluded)Onlyonunitsupto30

    RB0522

    Directexpansion/FreeCooling

    Onlyonunitsfrom3

    0RB0262to30RB0522

    CCNtoJ-Busgateway

    CompliancewithAustralanregulation

    Storagetemperatureabove

    48C

    CC

    NtoBacnetgateway

    CCNto

    Longateway

    EnergyManagementModule

    Sealedvalve

    Supersedes :January 04 th, 2008

    Product sourcing :

    CARRIER SCS

    BP 49 - 01122 MONTLUEL Cedex - France

    ----------------------------------------------

    Page No 13/13 Effective Date : June 01 st, 2008