314595_pdf
DESCRIPTION
emc314595_PDFTRANSCRIPT
Symmetrix VMAX Series: Error code: 3C3Eoccurring on SAF
Article Number:000090553 Version:3 Key Information
Audience: Level 40 = Employeesand Partners
Original Create Date: Tue Jan 2216:27:05 GMT 2013
Article Type: Break Fix
Channels: Customer , Internal App First Published: Wed May 2920:38:06 GMT 2013
Validation Status: Final Approved
Originally Created By: PaulDwyer
Last Modified: Fri Aug 0921:00:09 GMT 2013
Last Published: Fri Aug 0921:00:09 GMT 2013
Summary:
Article Content
Issue:Error code: 3C3E occurring on SAF.Error code: 3C3C occurring on SAF.
Error code: 2812 occurring on SAF.
Error code: DEDA occurring on DAF.
Error code: DA02 occurring on DAF.
Error code: 282C
Environment: Product: Symmetrix VMAX SeriesEnginuity: 5876
Device Emulation: FBA
Configuration: Thin Device
Configuration: Meta Volume
No gatekeepers on the SAF ports.
Gatekeepers are configured but are masked off the SAF ports.
Cause: The 3C3E or 3C3C results from a call in the code to set "free_scratch_slot_p_dv_specify_return_no_indirect_TID_read" in the options flags. When this is aThin device, during the scratch slot unlock, the code ends up re-reading the I table of the first trackfrom the source device. This then results in the code overwriting the current WP sector signatures inthe device record, and when the code calls "move_safe_write_context" out of the meta switch, thisold value from global memory is what is copied over as the expected "new" sector signature. Thisscratch slow options flags command does not exist in Enginuity 5875.
Resolution: Field Service:
An OPT has been opened with Engineering and a permanent fix is in progress. Contact theSupport Center for escalation to a Recovery Team Data Structures SME and quote this solutionID.For 5876:Fix 66424 is released GA at 5876.229.145 and also available in an Enginuity Pack for5876.159.102 .
Notes(Restricted):
Support Center:
OPT: 413847
Escalate any DEDA, DA02, or 282C to a Recovery Team Data Structures SME. An OPTFix:has been opened with Engineering and a permanent fix is in progress.For 5876:Fix 66424 is released GA at 5876.229.145 and also available in an Enginuity Pack for5876.159.102 .
Workaround: Have the Gatekeeper devices added or have the customer unmask them.
Article Metadata
Product: Symmetrix VMAX 10K (Systems with SN xxx987xxxx), Symmetrix VMAX 40K, SymmetrixVMAX Cloud Edition, Symmetrix VMAX Series, Symmetrix VMAX/VMAX 20K, SymmetrixEnginuity 5876
Firmware: Enginuity 5876
Hardware Platform: Symmetrix VMAX Series
Problem Code: Code Bug;EMC Firmware
Shared: Yes
RCA Status: In Process-Engineering
Bug Tracking Number: 413847
External Source: Primus
Primus/Webtop solution ID: emc314595
Originally Created By: Paul Dwyer