32-samss-037
DESCRIPTION
erwrTRANSCRIPT
-
Previous Issue: New Next Planned Update: 1 November 2016
Page 1 of 29
Primary contact: Mehdi, Mauyed Sahib on 966-3-8809547
CopyrightSaudi Aramco 2011. All rights reserved.
Materials System Specification 32-SAMSS-037 1 November 2011 Material Specification for the Manufacture of Fiber Reinforced Plastic (FRP) Tanks
Document Responsibility: Materials and Corrosion Control Standards Committee
Saudi Aramco DeskTop Standards Table of Contents 1 Scope................................................................. 2
2 Conflicts and Deviations.................................... 2
3 References........................................................ 2
4 Definitions.......................................................... 6
5 Raw Materials.................................................... 9
6 Laminates........................................................ 19
7 Inspection and Quality Assurance Requirements........................... 24
8 Documentation................................................ 27 Appendix A - Workflow for the Material Selection and Testing of FRP Tanks...... 29
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 2 of 29
1 Scope
1.1 This document covers the requirements for specification of and the acceptance
conditions for raw materials, properties, and testing of materials utilized for the
factory manufacture of fiber reinforced plastic (FRP) tanks, for use above
ground or underground.
1.2 The FRP tanks made of polyester, vinylester or epoxy resin system reinforced
with glass fibers, carbon fibers, or their combination, manufactured by the wet
lay-up and/or filament winding processes. Constructions both with and without
a lining of thermoplastics are included.
1.3 This specification applies to stationary tanks used for the storage, accumulation,
or processing of corrosive or other substances at pressures not exceeding 15 psig
external and/or 15 psig internal above any hydrostatic head.
1.4 The process for the material specification and quality control tests according to
this document is shown in flowchart, Figure A of the Appendix A.
2 Conflicts and Deviations
2.1 Any conflicts between this specification and other applicable Saudi Aramco
Materials System Specifications (SAMSSs), Engineering Standards (SAESs),
Standard Drawings (SASDs), or industry standards, codes, and forms shall be
resolved in writing, prior to submission of bids or start of related work, by the
Company or Buyer Representative through the Manager, Consulting Services
Department, of Saudi Aramco, Dhahran.
2.2 Direct all requests to deviate from this specification in writing to the Company or
Buyer Representative, who shall follow internal company procedure SAEP-302
and forward such requests to the Manager, Consulting Services Department of
Saudi Aramco, Dhahran.
3 References
Material supplied to this specification shall comply with the latest edition of the
references listed below unless otherwise noted:
3.1 Saudi Aramco References
Saudi Aramco Engineering Procedure
SAEP-302 Instructions for Obtaining a Waiver of a Mandatory
Saudi Aramco Engineering Requirement
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 3 of 29
Saudi Aramco Materials System Specification
32-SAMSS-002 Manufacture of FRP Storage Tanks
Saudi Aramco Engineering Standard
SAES-D-110 Design of Fiberglass-Reinforced Plastic (FRP)
Storage Tanks
3.2 Industry Codes and Standards
American Society of Mechanical Engineers
ASME RTP-1 - 2007 Reinforced Thermoset Plastic Corrosion-Resistant
Equipment
American Society for Testing and Materials
ASTM C581 Determining Chemical Resistance of Thermosetting
Resins Used in Glass-Fiber-Reinforced
Structures Intended for Liquid Service
ASTM C582 Specification for Contact-Molded Reinforced
Thermosetting Plastic (RTP) Laminates for
Corrosion-Resistant Equipment
ASTM D638 Test Method for Tensile Properties of Plastics
ASTM D648 Standard Test Method for Deflection Temperature
of Plastics under Flexural Load in the Edgewise
Position
ASTM D790 Test Methods for Flexural Properties of
Unreinforced and Reinforced Plastics and
Electrical Insulating Materials
ASTM D2583 Test Method for Indentation Hardness of Rigid
Plastics by Means of a Barcol Impressor
ASTM D2584 Test Method for Ignition Loss of Cured Reinforced
Resins
ASTM D 3299 Standard Specification for Filament-Wound Glass-
Fiber-Reinforced Thermoset Resin Corrosion-
Resistant Tanks
ASTM D4097 Standard Specification for Contact-Molded Glass-
Fiber-Reinforced Thermoset Resin Corrosion-
Resistant Tanks
ASTM D5083 Test Method for Tensile Properties of Reinforced
Thermosetting Plastics Using Straight-Sided
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 4 of 29
Specimens
ASTM E84 Standard Test Method for Surface Burning
Characteristics of Building Materials
European Standard
EN 59 Glass Reinforced Plastics - Measurement of
Hardness by Means of a Barcol Impressor
EN 29092 Textiles - Nonwovens - Definition
EN 13121-1 GRP Tanks and Vessels for Use above Ground -
Raw Materials - Specification Conditions and
Acceptance Conditions
EN 13121-2 GRP Tanks and Vessels for Use above Ground -
Composite Materials - Chemical Resistance
EN 13121-3 GRP Tanks and Vessels for Use above Ground -
Design and Workmanship
EN 13121-4 GRP Tanks and Vessels for Use above Ground -
Delivery, Installation and Maintenance
International Organization for Standardization
ISO 75-2 Plastics - Determination of Temperature of
Deflection under Load -
Part 2: Plastics and Ebonite
ISO 178 Plastics - Determination of Flexural Properties
ISO 306 Plastics - Thermoplastic Materials - Determination
of Vicat Softening Temperature (VST)
ISO 472 Plastics - Vocabulary (ISO 472:1999)
ISO 527-2 Plastics - Determination of Tensile Properties -
Part 2: Test Conditions for Moulding and
Extrusion Plastics
ISO 868 Plastics and Ebonite - Determination of Indentation
Hardness by Means of a Durometer (Shore
Hardness)
ISO 1133 Plastics - Determination of the Melt Mass-Flow
Rate (MFR) and the Melt Volume-Flow Rate
(MVR) of Thermoplastics
ISO 1163-1 Plastics - Unplasticized Poly (Vinyl Chloride)
(PVC-U) Moulding and Extrusion Materials -
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 5 of 29
Part 1: Designation System and Basis for
Specifications
ISO 1183 Plastics - Methods for Determining the Density and
Relative Density of Non-Cellular Plastics
ISO 1887 Textile Glass - Determination of Combustible-
Matter Content
ISO 1889 Reinforcement Yarns - Determination of Linear
Density
ISO 2113 Reinforcement Fibers - Woven Fabrics - Basis for a
Specification
ISO 2554 Plastics - Unsaturated Polyester Resins -
Determination of Hydroxyl Value
ISO 2559 Textile Glass - Mats (Made from Chopped or
Continuous Strands) - Designation and Basis for
Specifications
ISO 2797 Textile Glass - Rovings - Basis for a Specification
ISO 3344 Reinforcement Products - Determination of
Moisture Content
ISO 3374 Reinforcement Products - Mats and Fabrics -
Determination of Mass per Unit Area
ISO 3915 Plastics - Measurement of Resistivity of Conductive
Plastics
ISO 6721-2 Plastics - Determination of Dynamic Mechanical
Properties - Part 2: Torsion-Pendulum Method
ISO 9073-1 Textiles - Test Methods for Nonwovens -
Part 1: Determination of Mass per Unit Area
ISO 9073-2 Textiles - Test Methods for Nonwovens -
Part 2: Determination of Thickness
ISO 9073-3 Textiles - Test Methods for Nonwovens -
Part 3: Determination of Tensile Strength and
Elongation
ISO 9771 Plastics - Phenolic Resins - Determination of the
Pseudo-Adiabatic Temperature Rise of Liquid
Resols when Cured under Acid Conditions
ISO 11357-2 Plastics - Differential Scanning Calorimetry (DSC)
- Part 2 Determination of Glass Transition
Temperature
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 6 of 29
ISO 11359-2 Plastics - Thermomechanical Analysis (TMA) -
Part 2: Determination of Coefficient of Linear
Thermal Expansion and Glass Transition
Temperature
Underwriters Laboratories
UL 1316 Glass-Fiber-Reinforced Plastic Underground
Storage Tanks for Petroleum Products, Alcohols,
and Alcohol-Gasoline Mixtures
4 Definitions
4.1 General
For purposes of this specification only, the following definitions apply:
Carbon fiber: fiber produced by pyrolysis of organic precursor fibers, such as
rayon, polyacrylonitrile or pitch, in an inert environment.
Chelating agents: organic compounds which act by temporarily complexing the
organometallic accelerator out of the reaction medium. Example, acetyl acetone.
Chemical protective barrier: either the corrosion-resistant barrier or the
thermoplastic liner (if used), whichever will be in direct contact with the fluid.
Corrosion-resistant barrier: the composite material layer of the tank that will be
in direct contact with fluid, it is comprised of an inner surface and interior layer.
Crosslinking: process which bonds one polymer chain to another, to form a
tridimensional polymeric structure.
Cure/Post cure cycle: time/temperature/pressure cycle used to cure a
thermosetting resin system.
Cure: chemical reaction resulting in crosslinking of thermoset resin.
Curing agent: catalytic or reactive agent that, when added to a resin, causes
crosslinking.
Design Engineer: engineering company responsible for specifying design
requirements on the tank data sheet. It is also referred to as engineering contractor.
E-glass: a grade or type of glass fiber normally used to reinforce FRP tanks,
consisting mainly of SiO2, Al2O3 and MgO.
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 7 of 29
Epoxy resins (EP): thermoset resin containing the oxirane (epoxide) reactive
group. Crosslinking occurs at these sites through addition of amines, Lewis
acids/bases and anhydrides. Examples, diglycidyl ether of bisphenol A,
diglycidyl ether of bisphenol F.
Fiber-reinforced plastic (FRP): plastic-based composite that is reinforced
with any type of fiber, not necessarily glass.
Glass transition temperature (Tg): temperature at which amorphous polymer
undergoes a marked change in properties on passing from the rubbery to glassy
state.
Gel coat: a thin layer of resin on the surface of a laminate that may or may not
be reinforced with a glass or a synthetic fiber.
Inhibitors: chemical agents which react with the curing system to slow down
the curing of the resin.
Initiators: generally organic peroxides which break down liberating radicals
initiating radical crosslinking process. Examples, Methyl ethyl ketone peroxide
(MEKP), Cumene hydroperoxide (CuHP), Dibenzoyl peroxide (BPO), acetyl
acetone peroxide (AAP), Cyclohexanone peroxide (CHP), etc.
Laminate: compilation of laminae of resin reinforced with fibers which are
fabricated during the manufacturing process of the tank. The laminate
constitutes the wall thickness structure of the tanks and their properties are
defined in Section 6 of this document.
Manufacturer: company responsible for the design, fabrication and testing of
tanks in accordance with this Specification. It is also referred to as Fabricator.
Maximum design temperature, Td: maximum temperature for determination
of the partial design factor, A2, as defined in EN 13121.
Maximum temperature, Tm: temperature given by the resin supplier or the
thermoplastics supplier referring to a specified fluid.
Organometallic accelerators: the primary agents which accelerate the
breakdown of the initiator to achieve a sufficient rate of generation of radicals.
Owner: Saudi Aramco organization which will utilize the tank and specify the
process requirements.
Post cure: the application of heat to take the resin crosslinking to a final stage.
Promoters: improve the reaction efficiency of the accelerators.
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 8 of 29
Saudi Aramco Inspector: the person or company authorized by the Saudi
Aramco Inspection Department to inspect tanks to the requirements of this
specification.
Unsaturated polyester resins (UP): thermosetting resins consisting of
polyester molecules dissolved in a reactive monomer, typically styrene, capable
of copolymerization with the polyester.
Vinylester resins (VE): thermosetting resins consisting of phenyl- and/or
phenylene derivates (e.g., dialkoxy-bisphenol A), fumaric/maleic acid,
diisocyanate derivates and terminated with alkoxy-(meth) acrylate.
4.2 Symbol and Abbreviations
Symbols and
Abbreviations Units Description
HDT C Heat deflection temperature
MFR g/10 min Melt flow rate
t % Elongation at break in tension
f MPa Flexural strength
t MPa Tensile strength
ShD - Shore Hardness D
g/ml Density
Et MPa Modulus of elasticity in tension
Ef MPa Modulus of elasticity in flexure
CSM - Chopped strand mat
GRP Glass-fiber Reinforced Plastic
ECTFE - Ethylene-chlorotrifluoroethylene copolymer
FEP - Fluorinated ethylene-propylene copolymer
FW - Filament winding
PFA - Perfluoro-alkoxy copolymer
PP-B - Polypropylene, block polymer
PP-H - Polypropylene, homopolymer
PP-R - Polypropylene, random polymer
PVC-U - Polyvinyl chloride, unplasticised
PVDF - Polyvinylidene fluoride
WR - Woven rovings
CRL - Chemical Resistant Layer
VL - Veil Layer
TPL - Thermoplastics Liner
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 9 of 29
5 Raw Materials
5.1 Resins
a) The resins used for FRP tanks are liquid or liquefiable, thermosetting in
nature and cured by molecule crosslinking (polyaddition or
polycondensation) with or without curing agents (initiators,
accelerators/promoters).
b) The resin supplier shall state in the resin technical data sheet the name,
type of resin, resin group and resin typical properties. Properties of UP
and VE resins are published in Table 1.
c) The tank manufacturer shall verify that the resin conforms to the property
values of color, viscosity, nonvolatile content and gel time as established
in the resin manufacturer technical data sheet.
d) Only resins with an HDT of at least 82C (180F) per ASTM D648 with a
1.8 MPa (264 psi) loading and a 3.2 mm (18 in) specimen shall be used.
e) The tank manufacturer shall verify resin meets the chemical resistance
requirements given in EN 13121-2.
Note: Orthophthalic acid based UP resins are not allowed to be used in the manufacture FRP tanks under this specification.
f) For the manufacture of fiber reinforced plastic underground storage tanks
for petroleum products, alcohols, alcohol-gasoline mixtures and Methyl
tert-butyl ether (MTBE), the resin systems shall meet the requirements of
UL 1316 Section 14.
g) The manufacturing procedure and cure schedule of thermosetting resin
laminates shall be in accordance with the resin supplier's
recommendations.
h) Most thermosetting resins require elevated temperature post cure to
enhance chemical and thermal resistance.
i) When required, flammability and electrical conductivity shall be taken into
consideration for the material to meet the requirements established in
Sections 6.1.6 and 6.1.7 of this document.
5.2 Curing Agents
5.2.1 Curing Agents for Unsaturated Polyester and Vinylester
a) The cure system supplier shall state the compatibility of the curing
system with the resins, give recommendations on the quantities and
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 10 of 29
conditions of use and state any limitations on use in service.
b) The type and level of initiator to be used shall be compatible with
the resin system used and service conditions.
Table 1 Classification Scheme for UP- and VE-Resins
f
MP
a
min
90
75
12
0
11
0
10
0
11
0
13
0
13
0
13
0
a
Eth
yle
ne-
, 1
,2-p
rop
yle
ne-
, die
thy
len
e-,
dip
ropy
len
e-,
neo
pen
tylg
lyco
l,
1,3
-bu
tan
edio
l 1
,4-b
uta
ned
iol
and
corr
esp
on
din
g
hal
og
enat
ed
gly
cols
b
May
als
o c
on
tain
cy
clic
un
satu
rate
d h
yd
roca
rbo
ns.
c
Rel
ated
to
th
e su
m o
f th
e d
iol
com
po
nen
ts
t
%
min
2.0
1.5
3.0
3.0
1,5
2.0
4.0
3.5
2.5
t
MP
a
min
60
50
75
65
50
60
75
75
75
HD
T
C
min
82
90
11
0
90
90
11
0
90
10
5
12
0
Tg
C
min
85
12
0
14
0
12
0
12
0
13
0
11
0
12
0
15
0
Con
ten
t
of
styre
ne
mass
-%
max.
50
50
50
55
45
55
55
50
50
Typ
e of
aci
ds
Iso
ph
thal
ic a
cid
, H
ET
aci
d,
Eth
yle
ned
icar
bo
nx
yli
c
acid
s
Iso
ph
thal
ic a
cid
, H
ET
aci
d,
Eth
yle
ned
icar
bo
nx
yli
c
acid
s
Ter
eph
thal
ic a
cid
, H
ET
acid
, E
thy
len
edi-
carb
onx
yli
c ac
ids
Iso
ph
thal
ic a
cid
,
Eth
yle
ned
icar
bo
nx
yli
c
acid
s
Eth
yle
ned
i-ca
rbo
nx
yli
c
acid
s
Eth
yle
ned
icar
bo
nx
yli
c
acid
s
Met
hac
ryli
c-/A
cry
lic
acid
Eth
yle
ned
icar
bo
nx
yli
c
acid
s
Met
hac
ryli
c-/A
cry
lic
acid
Ty
pe
of
gly
cols
Sta
nd
ard
gly
cols
a,
b
Sta
nd
ard
gly
cols
a
Sta
nd
ard
gly
cols
a
Neo
pen
tyl
(min
. 80
mo
l-%
)c
and
a d
iol
wit
h a
t le
ast
on
e
seco
nd
ary
OH
-gro
up
(max
.
20
mo
l-%
)c
Bis
(h
yd
rox
ym
eth
yl)
-
tric
ycl
od
ecan
Dip
rop
ox
y-B
isp
hen
ol
A
(min
. 90
mo
l-%
)
Ep
ox
idis
ed B
isp
hen
ol
A
Dia
lko
xy
- B
isp
hen
ol
A
(min
. 90
ml-
%),
Alk
ox
y
(met
h)a
cry
late
Ep
ox
idis
ed-N
ov
ola
k
Res
in
Ty
pe
UP
UP
UP
UP
UP
UP
VE
UV
E
VE
Res
in
Gro
up
2A
2B
3
4
5
6
7A
7B
8
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 11 of 29
c) Organometallic accelerator usually used is cobalt naphthenate or
cobalt octoate.
d) Promoters are typically Dimethylaniline (DMA), Diethylaniline
(DEA), dimethylacetoacetamide (DMAA). When used with BPO,
promotors can act on the peroxide without the need for
organometallic accelerators. DMA/BPO system is required, at
least, to manufacture the corrosion resistance barrier of tanks to be
in hypochlorite service.
e) Inhibitors are normally alkylated phenols (e.g., tertiary butyl
catechol - TBC) which react with free radicals to form more stable
and less reactive species. With certain resin grades (e.g., VE)
chelating agents are also used.
f) The tank manufacturer shall verify that all curing system
components conform to the property values established in the
supplier technical data sheet.
5.2.2 Curing Agents for Epoxy Resin
a) Four major types of curing agent can be utilized to crosslink epoxy
resin utilized in the manufacture of FRP tanks, and these include;
aliphatic, (cyclo) aliphatic or aromatic amine, and anhydride.
b) The maximum operating temperature for tanks manufactured out of
epoxy resin and the above curing agents are shown in Table 2.
c) The glass transition temperature (Tg) of the resin system shall be
20C above the maximum design and operating temperature.
The resin cure may be verified by a glass transition test using
differential scanning calorimetry (DSC), Heat Deflection
Temperature (HDT) or dynamic mechanical analysis (DMA).
Table 2 Maximum Operating Temperature for Tanks Manufactured out of Epoxy Resin as a Function of the type of Curing Agents
Curing Agent Maximum Temperature, C (F)
Anhydride 65 (150)
Aliphatic Amine 93 (200)
Cyclo-Aliphatic Amine 110 (230)
Aromatic Amine 115 (240)
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 12 of 29
d) In each material data sheet(s), the material supplier shall state the
name and type of curing agent and the typical properties.
e) The tank manufacturer shall verify that the curing agent conforms
to the property values of color, viscosity, gel time and anhydride
equivalent as established in the curing agent technical data sheet.
5.3 Reinforcing Materials
5.3.1 General
Reinforcing materials shall be made from different types of textile glass
in accordance with Table 3. Special arrangement of reinforcing material
should be specified taking into account requirements as defined in 5.2.2
to 5.2.5.
Table 3 The of Glass Fibers Used as the Reinforcement of FRP Tanks
Glass Fiber Types Maximum Temperature, C (F)
E Alumina-borosilicate glass, 1% Alkali content
E-CR Alumina-limesilicate glass, 1% Alkali content
AR Zirconium-lime glass, 15% Zirconium content
A Alkali-lime glass, 15% Alkali content
C Alkali-lime glass, 8% Alkali content
5.3.2 Surface Nonwovens Fabric (Veils)
a) The surface nonwoven fabric supplier shall state the material
filament structure, binder, sizing and mass per unit area and its
compatibility with the resin system and the laminating process.
b) Surface nonwovens fabric shall be made from filaments of textile
glass or textile of synthetics, e.g., polyacrylonitrile, polyamide,
polyester or of carbon fibers, with or without orientation, and
having mass per unit area between 20 to 55 g/m. Typical veil
materials used in the corrosion resistance barrier are:
Glass Surfacing Veil. C-Glass surfacing veil, 0.25 mm (10 mls) thick, with a silane-type finish and a binder compatible with the
lay-up resin.
Organic Surfacing Veil. Organic surfacing veil, apertured or non-apertured polyester veil, 0.3 to 0.4 mm (12 to 16 mls)
thick, with a finish compatible with the lay-up resin.
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 13 of 29
Carbon Surfacing Veil. Carbon surfacing veil, 20 g/m2 (0.6 oz/yd
2), 0.15 mm (6 mls) thick, with a finish compatible
with the lay-up resin.
c) Surface nonwovens fabric shall be in accordance with the
specification of the supplier. The material data sheets shall state
the name, identity mark, material, type of filament, binding and the
properties.
d) The tank manufacturer shall verify that the surface nonwoven
fabric conforms to the property values of mass per unit area,
thickness and tensile strength as established in the fabric data sheet.
5.3.3 Chopped Strand Mats
a) The chopped strands mat supplier shall state the strand, structure,
binder and mass per unit area, the compatibility with the resin
system, the laminating process and the laminate design.
b) Chopped strand mats shall be made of textile glass strand, cut from
25 to 50 mm in length, without orientation of strands, and mass per
unit area within 225 to 600 g/m2. Chopped strands mat typically
used are type E (electrical borosilicate) or ECR (electrical corrosion-
resistant) glass; 236, 354, or 472 g/m2 (0.75, 1, or 1.5 oz/ft
2), with a
silane-type finish.
c) The material data sheets the material provided by supplier shall
state the name, identity mark and properties of the chopped strand
mats in accordance with ISO 2559 or equivalent.
d) The tank manufacturer shall verify that the chopped strand mat
conforms to the property values of mass per unit area, thickness
and tensile strength as established in the chopped strand mat data
sheet.
5.3.4 Woven Fabrics/Woven Roving Fabrics
a) Fabric shall be made of glass yarns or rovings. The fabric supplier
shall state the grade of yarns or roving, structure, finish and mass
per unit area and the compatibility with the resin system, the
laminating process and laminate design.
b) The fabric supplier shall state the linear density of yarns or rovings,
by ratio of mass of warp to weft, bidirectional or unidirectional.
Mass per unit area shall be within 240 to 1,200 g/m2. Woven
roving could be E glass, nominal 813 g/m2
(24 oz/yd2), 5 x 4 square
weave, with a silane-type finish.
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 14 of 29
c) The Fabric shall be in accordance with ISO 2113 or equivalent.
d) Special fabrics, e.g., combined chopped strand mat/woven fabrics
or multi axial fabrics may be used in accordance with the
requirements of the European Standard EN 13121.
e) The individual material data sheets of the fabrics provided by the
material supplier shall include the name, identity mark and
properties in accordance with ISO 2113 or equivalent.
f) The tank manufacturer shall verify the fabric conforms to the
property values of mass per unit area, thickness and tensile strength
as established in the fabric data sheet.
5.3.5 Rovings for Winding and for Chopping Applications
a) Rovings shall be made of glass textile. The rovings supplier shall
state the grade of filament, linear density and sizing and as well as
the compatibility with the resin system, radial or helical winding
process and the laminate design.
b) Rovings for filament winding or for chopping applications shall be
specified by their linear density and sizing agent.
c) Rovings for filament winding or for chopping applications shall be
in accordance with ISO 2797 or equivalent.
d) The individual material data sheets of the roving provided by the
material supplier shall include the name, identity mark and
properties in accordance with ISO 2797 or equivalent.
e) The tank manufacturer shall verify the roving conforms to the
property values of linear density, filament diameter, type of sizing
and tensile strength as established in the roving data sheet.
5.4 Additives
5.4.1 General
a) The representative properties of any additive used shall be stated.
b) If any additives are incorporated into the resin system by the
manufacturer of the tank, the manufacturer shall inform the
purchaser of the inclusion of any such additives before manufacture
commences.
c) The additives shall be used in accordance with the resin and/or
additive supplier's recommendations.
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 15 of 29
5.4.2 Thixotropic Agents
Thixotopic agents such as fumed silica may be added to the resin up to
5% by mass, using a high shear stirrer, for viscosity control, provided it
does not interfere with visual inspection.
5.4.3 Conductive Fillers
a) Conductive fillers such as graphite or carbon black may be added
to the resin in order to meet any requirements for electrical
conductivity of the laminates. Such fillers may also be used in
conductive pastes used to facilitate spark testing of welds in
thermoplastics linings.
b) Conductivity can also be achieved by the utilization of carbon fiber
or other conductive fibers.
5.4.4 Fire Retardants
Fire retardants such as aluminium trihydrate or antimony oxides may be
added to specified laminate layers to meet certain requirements for fire
resistance. No fire retardants other than those present in the fire
resistance test sample will be allowed to be used during fabrication of the
tank(s). The tank manufacturer shall demonstrate that the incorporation
of the fire retardant additives will not negatively affect the mechanical
and physical material properties.
Special intumescent coatings can also be utilized to improve the fire
resistance of the material utilized to manufacture the tank.
5.4.5 Paraffin Wax
a) The final layer may contain paraffin wax in order to meet
requirements for surface cure.
b) The wax should have a melting point of 40 to 60C and should be
added to the resin in the form of a 10% solution in styrene so as to
achieve a wax content of 0.2 to 0.8% by mass.
5.4.6 Aggregates and Fillers
Neither aggregates (inert granular material) nor other inert fillers shall be
incorporated into the laminate structure. Fillers may be used to
formulate resin pastes.
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 16 of 29
5.4.7 Ultraviolet Absorbers
When required, ultraviolet absorbers may be incorporated into the
laminate or outer layers, in accordance with the supplier's
recommendations (usually used at a level of less than 0.5% by mass).
5.4.8 Pigments
Pigments are permissible only in the outer resin surface and - if required
- shall be applied after visual inspection has been carried out.
5.4.9 Paints and Coatings
Polyurethane based coating systems can be applied on the external
surface of the tank - if required - and shall be applied after visual
inspection has been carried out.
5.4.10 Surface active agents
Surface active agents may be added to the resin to improve its
processability. Examples of this type of additive are those used as air
release agents, wetting agents, activators for thixotropic agents and
monomer emission suppressants.
5.5 Thermoplastic Lining Materials
5.5.1 General
a) Lining materials shall be selected from the following thermoplastics:
Polyvinylchloride in accordance with EN 13121-1 or ASME RTP-1
PVC-U
Chlorinated Polyvinylchloride in accordance with ASME RTP-1
CPVC
Polypropylene (homo, block and random polymers) in accordance with
EN 13121-1 or ASME RTP-1
PP-H, PP-B, PP-R
Polyvinylidene fluoride in accordance with EN 13121-1 or ASME RTP-1
PVDF
Ethylene-chlorotrifluoroethylene copolymer in accordance with
EN 13121-1 or ASME RTP-1
E-CTFE
Fluorinated ethylene-propylene copolymer in accordance with
FEP
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 17 of 29
EN 13121-1 or ASME RTP-1
Perfluoro-alkoxy copolymer in accordance with EN 13121-1 or
ASME RTP-1
PFA
Ethylene-tetrafluoroethylene in accordance with ASME RTP-1
ETFE
Polytetrafluoroethylene in accordance with ASME RTP-1
PTFE
High Density Polyethylene in accordance with ASME RTP-1
HDPE
b) The lining material shall be selected on the basis of its ability to meet
the requirements for service conditions including permeability,
environmental stress cracking, mechanical properties, bond strength
to laminate and fabricability (forming, welding) per EN 13121-2 and
EN 13121-3, or ASME RTP-1.
c) All parts of the lining shall be manufactured from the same grade of
material.
d) The thermoplastic lining supplier shall state that the specific linings
meet the chemical resistance requirements given in EN 13121-2.
e) When required, flammability and electrical conductivity shall be
taken into account.
5.5.2 Liner Thickness
a) The liner will be thick enough so that permeation will be low to
minimize FRP structure chemical exposure. However, the liner will
not be too thick that anticipated forming processes during fabrication
will cause damaging stresses and possible failure.
b) The required thickness for the thermoplastic liners is shown in
Table 4.
Table 4 Required Thickness of Thermoplastics Liners
Material Thickness of Sheets, mm
PVC-U 3.0 to 4.5
CPVC 3.0 to 4.5
PVDF 2.4 to 4.0
PP-H,-B,-R 3.0 to 6.0
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 18 of 29
Material Thickness of Sheets, mm
E-CTFE, FEP, PFA, ETFE 1.7 to 2.5
PTFE 2.5 to 4.0
HDPE 3.0 to 6.0
5.5.3 Mechanical and Thermal Properties
a) The lining material properties shall conform to the results of the
properties outlined in values given in Table 5.
b) The actual results shall be stated by the supplier of the lining
material.
c) The tank manufacturer shall verify that the liner material conforms
to the property values of dimensions, mechanical and thermal
properties as established in Table 5.
5.5.4 Welding consumables
All welding rods shall be of the same or compatible grade of material of
the lining and shall not impair the performance of the lining.
5.5.5 Dimensional stability
In order for the lining to retain its dimensional stability during heat
forming and welding, the thermoplastic lining material shall conform to
the requirements for heat reversion as specified by the material supplier.
Table 5 Properties of the Thermoplastic Sheet Material[1]
Material
Type
Density
ISO 1183
Vicatb
softening
Temperature
EN ISO 306
Tensile
Strength at
Break
EN ISO
527-2
Tensile
Strain at
Break
EN ISO
527-2
Modulus of
Elasticity in
Tension
EN ISO
527-2
Shore D
Hardness
EN ISO 868
Heat
Deflection
Temperature
EN ISO 75-
2c
Linear
Thermal
Expansion
ISO 11359-
2
(g/cm3) (C) (MPa) (%) (MPa) (C) (C)
PVC-U 1.45 75 55 15 3000 80 75 75
CPVC 1.50 --- 55 15 3000 --- 102 120
PP-H 0.91 --- 30 > 50 1200 65 50 180
PP-B 0.91 --- 20 > 50 700 60 45 180
PP-R 0.91 --- 20 > 50 700 60 45 180
PVDF 1.78 145 50 80 2000 80 90 130
E-CTFE 1.69 115 45 200 1700 75 75 80
FEP 2.15 70 25 300 350 55 50 100
PFA 2.15 75 30 300 300 60 60 140
ETFE 1.70 --- 45 250 1656 --- 104 80
PTFE or TFE 2.1-2.3 --- 20 250 450 --- 221 120
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 19 of 29
HDPE 0.95-0.97 --- 22-31 >500 1100 --- 85 150 a method MFR 190/5
b method VST/B
c method A
[1]: Relevant ASTM standard test methods shall be used for suppliers following ASTM/ASME documents.
6 Laminate Requirements
6.1 General
The laminate properties specified in this section will be used as baseline for the
quality control test to be conducted on the final material produced during the
manufacture of the tank. The quality control tests should be carried out
according to Section 7 of this specification.
If the laminate properties are defined by conducting tests from prototype
samples, these tests can be conducted by the liner supplier, tank manufacturer or
independent testing laboratory.
The quality of lamination work depends on the skill, knowledge and experience
of the laminator. Periodic assessment of the skill of the laminator is essential for
the assurance of the quality of the lamination work. The methodology to assess
the the knowledge and skills of laminators who are required to carry out work on
FRP tanks is described in ASME RTP-1 Mandatory Appendix M-5 or
EN 13121-3 Annex E. All laminators shall have documented experience as a
laminator or have completed a training course. The tank manufacturer shall
demonstrate that their laminators have been trained and certified by either of the
assessment procedures mentioned above.
6.1.1 Chemical Protective Barrier
6.1.1.1 General
The chemical protective barrier shall be selected in accordance
with the requirements of EN 13121-2. The chemical barrier
construction shall not be considered in any strength, or stability
calculation.
6.1.1.2 Corrosion-Resistance Barrier (Resin Based)
Laminates shall consist of a resin based corrosion-resistant
barrier (comprised of an inner surface and an interior layer) and
a structural layer. The reinforcement content of the corrosion
barrier shall be between 20% to 30% by weight.
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 20 of 29
a) Inner Surface. The inner surface exposed to the fluids
shall be a resin rich layer reinforced with a surfacing veil
providing a thickness of 0.25 mm to 0.5 mm (0.01 in. to
0.02 in). The surface veil (VL) may be either C glass,
synthetic veil, carbon fiber or ECR glass.
b) Interior Layer. The inner surface layer, which is exposed
to the service fluids of the tank shall be followed with an
interior layer. This layer is composed of resin reinforced
with noncontinuous glass fiber strands (25.4 mm to
50.8 mm long), applied in a minimum of two plies
totaling a minimum of 450 g/m2. These plies shall be
layers of chopped strand mat and/or chopped roving.
Each ply of mat or pass of chopped roving shall be well
rolled to thoroughly wet out the reinforcement and
remove entrapped air prior to the application of additional
reinforcement. The combined thickness of the inner
surface and interior layer shall not be less than 2.5 mm.
The corrosion-resistant barrier is to exotherm and cool
before the structural layer is applied.
6.1.1.3 Thermoplastic Liners
a) The thermoplastic liners shall be fabricated according to
the requirements of ASME RTP-1 Mandatory Appendix
M-12.
b) The selected thermoplastic liner shall be included in the
analysis, but will not be considered to add to the overall
strength of the structure of the tank.
c) The tank manufacturer shall supply the liner properties
and documents with the design package, including:
Liner thickness and properties according to Tables 4 and 5 of this specification.
Weld procedures for the different thermoplastic liners.
The welders shall be qualified according to the requirements of ASME RTP-1, Article H of the
Mandatory Appendix M-12; or EN 13121-3, Annex F.
The tank manufacturers shall hold the qualification
reports for all the thermoplastic liner welders.
Thermoplastic weld strength tested according to
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 21 of 29
ISO 527-2 or ASTM D638.
Bend tests for welds in thermoplastic when tested according to the test method described in Annex D.4
of EN 13121-3.
Lap shear strength of bond between thermoplastics liner and laminate when tested according to the test
method described in Annex D.8 of EN 13121-3.
The minimum bond shear strengths for thermoplastic
liners are shown in Table 6.
Table 6 Minimum Bond Shear Strengths for Thermoplastics Linings
Property Shear Strength, N/mm
PVC-U 7.0
CPVC 7.0
PVDF 5.0
PP-H,-B,-R and HDPE 3.5
E-CTFE, FEP, PFA, ETFE, PTFE 5.0
Peel strength to establish the bond strength between liner and laminate when tested according to the test
method described in Annex D.9 of EN 13121-3.
d) The thermoplastic liner supplier shall state that the liner
meet the chemical resistance requirements given in
EN 13121-2.
6.1.2 Structural Layer
a) The physical and mechanical properties of the laminate(s) which
will be used in the fabrication of the different shells of the
composite tank shall be provided by the tank manufacturer.
These laminates shall have the following glass content by mass:
Chopped strand mat (CSM) laminates: 25% to 35%;
Woven roving (WR) laminates: 45% to 55%;
Filament wound (FW) laminates: 60% to 75%.
b) The minimum specified properties shall be supplied by the tank
manufacturer in the design package for each wall construction of
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 22 of 29
the tanks, body shell, bottom and top head. The properties are
defined below.
% of glass content (loss on ignition) according to the test method of ASTM D2584;
Tensile modulus of laminate according to the test method of ASTM D638 or ASTM D5083;
Ultimate tensile strength according to the test method of ASTM D638 or ASTM D5083;
Inter-laminar shear test (based on max. shear load over a specified shear length) according to the test method describe in
Annex D.7 of EN 13121-3;
Barcol hardness test according to ASTM D2583 test method;
Short term creep test according to the test method described in Annex D.10 of EN 13121-3;
Flexural strength of laminate according to ASTM D790 test method.
Flexural modulus of laminate according to ASTM D790 test method.
These properties can be specified according to the results shown in
ASME RTP-1, Table 2A-3 or Mandatory Appendix M-3, EN
13121-3 Table 3, or tests carried out by tank manufacturer or
independent and certified testing laboratory.
c) In acid services such as H2SO4, HCl, HNO3, only ECR glass
reinforcing fibers shall be utilized for the manufacturing of the
structural layer.
d) When thermoplastic lining material is utilized, additional tests as
specified in with Section 6.1.1.3 of this specification shall be
carried out.
6.1.3 Outer Surface
a) The outer surface of the finished laminate shall be a separately
applied paraffinated (waxed) resin coat that, when cured, passes the
acetone test per ASTM C 582, Section 9.2.2. This outer surface
coat shall either be applied over the final mat ply of the structural
layer or over an additional resin-rich layer when required by
Section 6.1.3(b) of this specification.
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 23 of 29
b) When the outer surface will be subjected to spillage or a corrosive
environment, a resin-rich layer, in accordance with Section 6.1.1.2
of this specification, shall be applied over the final mat ply of the
structural layer prior to the application of the paraffinated (waxed)
resin coat in Section 6.1.3(a) above.
c) Provisions are required to minimize ultraviolet degradation of the
laminate surface. Methods include use of ultraviolet absorbers,
screening agents, or resins resistant to ultraviolet degradation,
polyurethane coatings or incorporation of pigment of sufficient
opacity in the paraffinated resin coat. Since pigmentation makes
laminate inspection difficult, the resin-rich layer shall be applied
only after the laminate has been inspected.
d) Where the final lay-up is exposed to air, full surface cure shall be
obtained by applying to the final layup a coat of paraffinated
(waxed) resin that, when cured, passes the acetone test per
ASTM C582, Section 9.2.2. Other techniques such as sprayed,
wrapped, or overlaid films are also acceptable methods to attain
surface cure, provided the surface resin under the film passes the
acetone test.
6.1.4 Heat Deflection Temperature (HDT)
a) The heat deflection temperature of cured resin system used for the
reinforced laminate shall be at least 20C higher than the design
temperature of the FRP tank.
When Design Temperature (TS) 60C; (HDT 82C)
When Design Temperature (TS) > 60C; (HDT - 40 C) TS
b) Only resins with HDT of at least 82C (180F) per ASTM D648
with a 1.8 MPa (264 psi) loading and a 3.2 mm (18 in) specimen shall be used.
6.1.5 Flammability
When required or specified, the external surface layer(s) of the tank shall
be modified to fulfill the required surface spread of flame characteristic.
The material shall show flame spread rating from 0 to 25 which
represents Class 1 rating for fire resistant material per ASTM E-84.
6.1.6 Electrical Resistivity
Where the build-up of static electricity may cause problems, the surface
resistivity of those parts of the tank or vessel in contact with the fluid
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 24 of 29
shall not exceed 106 , or the volume resistivity 106 m, when tested in
accordance with ISO 3915 test method.
6.1.7 Post-Curing
a) If required by design, the FRP tank manufactured following this
specification should undergo a thermal post-curing treatment using
hot air or similar heating system. This treatment, which must be
carried out at controlled temperature and time, has the aim of
perfecting the crosslinking of the resin, guaranteeing the very best
chemical and mechanical performance of the tank.
b) The tank manufacture shall have written procedures for the post-
curing process of the FRP tank.
c) Recommended timings and temperatures are summarized in Table 7.
Table 7 Recommended Post-curing Schedule for FRP Tanks
Type of Resin Temperature
C Time
Hours
Polyester - Isophtalic 70 (-3/5) 6 (-1/+2)
Polyester - Bisphenol 70 (-3/5) 10 (-1/+2)
80 (-3/5) 6 (-1/+2)
Vinylester 70 (-3/5) 12 (-1/+2)
80 (-3/5) 8 (-1/+2)
7 Inspection and Quality Assurance Requirements
Quality control records required by this specification shall be legible, identifiable,
retrievable and protected from damage, deterioration, or loss. These records shall be
retained by the tank manufacturer for a minimum of five years following the date of
manufacture. All quality control records required by this specification shall be signed
and dated, as established by the manufacturer's procedures.
7.1 Raw Materials
7.1.1 Matrix Material: Resin and Curing Agent
a) This section specifies the minimum requirements for the
inspections and tests that are to be performed by the tank
manufacturer or an independent testing laboratory on resins and
curing agents (curing agents include accelerators, promoters, and
peroxides as required for specific resin systems) according to the
requirements of ASME RTP-1 Mandatory Appendix M-2.
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 25 of 29
b) The requirements of this section shall be accomplished prior to
acceptance of resins and curing agents for fabrication of tanks to
this Specification. These requirements will help ensure that the
resins and curing agents are correctly identified; meet the
manufacturers specification; and are suitable for proper fabrication, curing practice, and design requirements of tanks
fabricated to this Specification.
c) The following tests shall be conducted on resins and curing agents;
Visual Inspection, Specific Gravity, Viscosity using Gardner-Holdt
Method or Brookfield Method, and Gel Time at room temperature.
d) These tests shall be performed on one random sample from each lot
or batch of material received from a supplier. If any containers or
packages are damaged, then the contents of each damaged
container shall be rejected.
7.1.2 Reinforcing Material
a) This section specifies the minimum requirements for the
inspections and tests that are to be performed by the tank
manufacturer or an independent testing laboratory on reinforcing
materials according to the requirements of ASME RPT-1
Mandatory Appendix M-1.
b) The requirements of this section are to be accomplished prior to
acceptance of reinforcement for fabrication of tanks to this
Specification.
c) These inspections shall be performed on one random sample from
each lot or batch of reinforcing material received from a supplier.
If any containers or packages are damaged, then the contents of
each damaged container shall be rejected.
7.1.3 Thermoplastic Liners
a) This section specifies the minimum requirements for the
inspections and tests that shall be performed by the tank
manufacturer or an independent testing laboratory on thermoplastic
liners according to the requirements of ASME RPT-1 Mandatory
Appendix M-12.
b) These inspections are to be performed on one random sample from
each lot or batch of material received from a supplier. If any
containers or packages are damaged, then the contents of each
damaged container shall be inspected according to section 7.1.3.a
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 26 of 29
of this specification. The requirements of this section are to be
accomplished prior to acceptance of liner for fabrication of tanks to
this Specification.
c) The weldability of the thermoplastic material is to be performed on
one random welded sample from each lot or batch of material
received for the sheets as well as for the welding consumables.
7.2 Quality Control test on Laminates
a) This section specifies the minimum requirements for the inspections and
tests that are to be performed by the tank manufacturer or an independent
testing laboratory on the laminate according to the requirements of
Section 6.1.2 of this specification.
b) The tank manufacturer shall verify that the laminate was fabricated
according to a given design parameters and drawings. The following
inspections and tests should be conducted according to ASME RTP-1 Part 6.
Resin cure. The test shall be conducted on the internal and external surfaces of the tanks according to ASME RTP-1/Section 6-910.
Barcol hardness shall not be lower than 90% of the value specified by
the resin supplier for a clear resin casting and according to the value
specified in Section 6.1.2.
Dimension and Laminate thickness checks are in accordance to ASME RTP-1 / Section 6-920.
Physical Property and Laminate Reinforcing Content Tests. These tests shall be conducted in accordance to ASME RTP-1/
Section 6-930. The Manufacturer is responsible for producing
laminates that will meet or exceed permissible physical and mechanical
properties used in the design and as are established as minimum within
Section 6.1.2. The physical and mechanical property average value
minus two standard deviations shall be higher than the specified value
given in Section 6.1.2. Laminates shall also be in accordance with the
reinforcing sequence and minimum reinforcing content established in
Section 6.1.2. The physical and mechanical properties shall be verified
from the tank cutout samples.
Glass content (loss on ignition)
Number of layers of glass, type and arrangement
Tensile modulus of laminate
Ultimate tensile strength
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 27 of 29
Inter-laminar shear test
Short term creep
Flexural strength of laminate
During fabrication, the manufacturer shall perform all such checks necessary to assure that laminate imperfections as defined in
ASME/RTP-1 Table 6-1 are within the requirements of this
Specification. Visual Inspection Acceptance Level shall be conducted
in accordance to the critical level services defined for the tank
application.
Where a thermoplastics liner is used, the mechanical property average values minus two standard deviations shall be higher than the specified
value given in Section 6.1.1.3 of this specification;
Lap shear strength
Peel strength
Note: If the tests cannot be conducted on samples machined from the FRP tanks cutouts (e.g., tank bottoms), the tank manufacturer shall fabricate at the same time the non-testable component is being made, a laminate piece, using the same materials as those being used for the non-testable component, this includes but is not limited to resin system, fiber amount and arrangement, and the same curing characteristics. This laminate piece shall be sufficiently sized such that all samples which would have been machined from a tank cut out can be obtained from the laminate piece.
8 Documentation
8.1 Documentation Provided by the Owner
The full information that shall accompany a purchase order for composite tank
as the Users Basic Requirements Specification, ASME RTP-1, Table 1.1.
8.2 Documentation Provided by the Tank Manufacturer
The tank manufacturer shall provide the Purchaser with a written description of
the composite tank system. As a minimum, this will include:
Fabricators Data Report
Drawings, including all tank dimensions, thickness, fitting and accessories locations, etc.
Definition of all raw material properties as established in Section 5 and
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 28 of 29
certified as required in Section 7.1, including tests report forms for all tests
performed on all lots or batches of materials used during fabrication.
Physical and Mechanical properties values utilized during the design as described in Section 6.1.2.
Physical and Mechanical properties values determined according to Section 7.2. of this specification.
Minimum and maximum operating temperatures.
Limitations with respect to chemical exposure.
Revision Summary
1 November 2011 New Saudi Aramco Materials System Specification.
-
Document Responsibility: Materials and Corrosion Control Standards Committee 32-SAMSS-037
Issue Date: 1 November 2011 Material Specification for the Manufacture
Next Planned Update: 1 November 2016 of Fiber Reinforced Plastic (FRP) Tanks
Page 29 of 29
Appendix A Workflow for the Material Selection and Testing of FRP Tanks
Users Basic Requirements Specification (UBRS)ASME RTP-1
By: Owner/ Design Engineer
Raw Materials Selection
Section 5, 32-SAMSS-037
By: Design Engineer/ Manufacturer
Material Parameters/ Data Sheet used in
Design of Laminate
Section 6, 32-SAMSS-037
By: Manufacturer
Revise/ Approve Material Selection
Sections 5 and 6, 32-SAMSS-037
By: Manufacturer
Tank Design
32-SAMSS-002
By: Manufacturer
Tank Manufacture
By: Manufacturer
Quality Control Test Raw Materials
Section 7.1, 32-SAMSS-037
By: Manufacturer
Quality Control Test Laminate
Section 7.2, 32-SAMSS-037
By: Manufacturer
Quality Control test Tank
32-SAMSS-002
By: Manufacturer
New Batch
Raw Materials
Tank Rejection
Yes
No
Yes
Yes
No
No
Appendix A Flowchart for Material Selection Criteria and Qualification Testing
Figure A Workflow for the Material Selection and Testing of FRP Tanks