36w reefer trailer heavy duty solar trickle charger€¦ · solar trickle charger-32r 762 mm 371 mm...
TRANSCRIPT
MERLIN® TECHNOLOGY
SYSTEM OVERVIEW
CUSTOMER BENEFITS
Industry leading power output | Enhanced performance under all light conditions | Designed and
engineered in USA | Outstanding aesthetics | Redundancy by design | Robust module integrity and
performance under extreme conditions | Military grade design, materials and approvals
Maintain 12V starter battery | Charge through optimized charge controller | Operational even on cloudy
days | Easy to install, peel & stick flexible panels | Built in diodes in the solar panel to handle shading
Trickle charges the reefer battery to accommodate parasitic loads | Prevents battery drainage as units sit
unused | Eliminates ”lot rot” at dealerships | Minimizes typical battery warranty issues | Reduces jump start
requirements | Maintenance free
MERLIN® GRID PATENTED TECHNOLOGY:
FLEXIBLE – RUGGED – LIGHTWEIGHT – MONO cSi
80% Lighter than Glass Panels
20% More Energy In Real World Conditions
50X More Durablevs. Bus-Bar Technology
2.5X Power Density vs. Thin Film Technology
FXTQ32R 36W REEFER TRAILER HEAVY DUTY SOLAR TRICKLE CHARGER
TECHNICAL SPECS
For further details, contact: MERLIN SOLAR TECHNOLOGIES, INC.
5891 Rue Ferrari, San Jose, CA 95138 | Ph: (408) 321-8258
E-mail: [email protected] | www.merlinsolar.com© 2019 Merlin Solar Technologies, Inc.
Distributed by:
W
V
A
V
A
%
%/oC
%/oC
%/oC
oC
32
36
17.01
2.11
20.46
2.18
18.4
IP Configuration
Charging Set Point
Operating Temperature
Dimensions
V
oC
mm
In
MERLIN® PV Module Specs1 Unit 32R
Charge Controller Key Specs
Cell Type Mono
Number of Cells
Rated Power (P Max)
Voltage at Pmax (Vmp)
Current at Pmax (Imp)
Open Circuit Voltage (Voc)
Short Circuit Current (Isc)
Active Area Efficiency
Temperature Co-efficient of Isc
Temperature Co-efficient of Voc
Temperature Co-efficient of Pmax
Operating Temperature
0.05
-0.33
-0.42
-40 to +85
IP68
14.1V
-40 to 60
64 x 51 x38
2.5 x 2.0 x 1.5
Mono
REEFER TRAILER HEAVY DUTY SOLAR TRICKLE CHARGER
-32R
762 mm
371 mm
18 mm 3.35 mm
1. STC standard test conditions: 1000W/m2 intensity, Air Mass 1.5, 25oC cell temperature. Power Tolerance is +/- 5% W at STC. The electrical characteristics are within +/- 10% unless otherwise specified2. Specifications are subject to change. Read more
SCHEMATIC CIRCUIT
ChargeController
Battery
Solar Panel
*Panel at the junction box area 18mm
Units
mm / kg
in / lb
Length Width Thickness* Weight
762
30
371
14³⁄5
3.35
7/10
1.36
3.0
Physical Characteristics