400v - lovato electric · 2010. 6. 22. · motor powerat 400v for contactors bf20, bf25, bf32,...
TRANSCRIPT
MOTORPOWER AT
400V
For contactorsBF20, BF25, BF32, BF40, BF50, BF65,BF80 and BF95
For mini-contactorsBG06, BG09 and BG12
11 SM1C 00 0,1÷0,1611 SM1C 04 0,16÷0,2511 SM1C 08 0,25÷0,411 SM1C 12 0,4÷0,6311 SM1C 16 0,63÷111 SM1C 20 1÷1,611 SM1C 24 1,6÷2,511 SM1C 28 2,5÷411 SM1C 32 4÷6,511 SM1C 36 6,3÷1011 SM1C 40 9÷1411 SM1C 44 13÷1811 SM1C 48 17÷2311 SM1C 52 20÷25
11 SM1B 00 0.1-0.16A11 SM1B 04 0.16-0.25A11 SM1B 08 0.25-0.4A11 SM1B 12 0.4-0.63A11 SM1B 16 0.63-1A11 SM1B 20 1-1.6A11 SM1B 24 1.6-2.5A11 SM1B 28 2.5-4A11 SM1B 32 4-6.5A11 SM1B 36 6.3-10A11 SM1B 40 9-14A11 SM1B 44 13-18A11 SM1B 48 17-23A11 SM1B 52 20-25A
electric
kW 0.370.51.1
0.7511.9
1.523.5
HPA (AC3)
Motor protection circuit breaker
Thermal trip adjustment range [A] ▲
Icu 400V [kA]
AC contactor
DC contactor
11 SM1B 20
1 - 1.6
100
11 BG06 A
11 BG06 D
11 SM1B 24
1.6 - 2.5
100
11 BG06 A
11 BG06 D
11 SM1B 28
2.5 - 4
100
11 BG06 A
11 BG06 D
Backup fuse aM [A]
AC contactor ■
DC contactor ■
Thermal overload relay manual reset
Set of relay-contactor links
Relay adjustment range [A] ❖
2
11 BG06 A
11 BG06 D
11 RF9 1V5
–
0.9 - 1.5
4
11 BG06 A
11 BG06 D
11 RF9 2V3
–
1.4 - 2.3
6
11 BG06 A
11 BG06 D
11 RF9 5
–
3 - 5
Backup fuse aM [A]
Assembled starter
Backup fuse aM [A]
Line contactor ■
Delta contactor ■
Star contactor ■
Thermal overload relay
Set of relay-contactor links
Time relay
Add-on auxiliary contact block
Add-on auxiliary contact block
Rigid connector kit
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
Quick backup fuse (Brush)
Soft-starter
By-pass contactor
–
–
–
–
–
–
–
–
–
2.235
11 SM1B 32
4 - 6.5
100
11 BG06 A
11 BG06 D
8
11 BG06 A
11 BG06 D
11 RF9 75
–
4.5 - 7.5
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
346.6
45.58.6
5.57.511.5
0.370.51.1
0.7511.9
1.523.5
2.235
346.6
11 SM1B 36
6.3 - 10
100
11 BG09 A
11 BG09 D
8
11 BG09 A
11 BG09 D
11 RF9 75
–
4.5 - 7.5
–
–
–
–
–
–
–
–
–
–
–
–
35 FE
51 ADXM 12B
incorporated
11 SM1B 36
6.3 - 10
100
11 BG09 A
11 BG09 D
10
11 BG09 A
11 BG09 D
11 RF9 10
–
6 - 10
–
–
–
–
–
–
–
–
–
–
–
–
35 FE
51 ADXM 12B
incorporated
11 SM1A 40
9 - 14
50
11 BG12 A
11 BG12 D
16
11 BG12 A
11 BG12 D
11 RF9 15
–
9 - 15
–
–
–
–
–
–
–
–
–
–
–
–
35 FE
51 ADXM 12B
incorporated
11 SM1B 20
1 - 1.6
100
11 BF9
11 BF9C
2
11 BF9
11 BF9C
11 RF25 1V5
–
0.9 - 1.5
–
–
–
–
–
–
–
–
–
–
–
–
35 FE
51 ADXM 12B
incorporated
11 SM1B 24
1.6 - 2.5
100
11 BF9
11 BF9C
4
11 BF9
11 BF9C
11 RF25 2V3
–
1.4 - 2.3
–
–
–
–
–
–
–
–
–
–
–
–
35 FE
51 ADXM 12B
incorporated
11 SM1B 28
2.5 - 4
100
11 BF9
11 BF9C
6
11 BF9
11 BF9C
11 RF25 5
–
3 - 5
–
–
–
–
–
–
–
–
–
–
–
–
35 FE
51 ADXM 12B
incorporated
11 SM1B 32
4 - 6.5
100
11 BF9
11 BF9C
8
11 BF9
11 BF9C
11 RF25 75
–
4.5 - 7.5
6
21 DYF9 E5
6
11 BF9 10
11 BF9 10
11 BF9 10
11 RF25 5
–
31 BT2N 12S
4 - 11 G480 11
–
11 SMX90 23
35 FE
51 ADXM 12B
incorporated
11 SM1B 36
6.3 - 10
100
11 BF9
11 BF9C
8
11 BF9
11 BF9C
11 RF25 75
–
4.5 - 7.5
8
21 DYF9 E5
8
11 BF9 10
11 BF9 10
11 BF9 10
11 RF25 5
–
31 BT2N 12S
4 - 11 G480 11
–
11 SMX90 23
10
21 DYF9 E75
10
11 BF9 10
11 BF9 10
11 BF9 10
11 RF25 75
–
31 BT2N 12S
4 - 11 G480 11
–
11 SMX90 23
35 FE
51 ADXM 12B
incorporated
45.58.6
5.57.511.5
7.51015.2
91218
111522
152028.5
18.52536
223042
304056
11 SM1B 36
6.3 - 10
100
11 BF9
11 BF9C
10
11 BF9
11 BF9C
11 RF25 10
–
6 - 10
35 FE
51 ADXM 12B
incorporated
16
21 DYF9 E75
16
11 BF9 10
11 BF9 10
11 BF9 10
11 RF25 75
–
31 BT2N 12S
4 - 11 G480 11
–
11 SMX90 23
11 SM1A 40
9 - 14
50
11 BF12
11 BF12C
16
11 BF12
11 BF12C
11 RF25 15
–
9 - 15
35 FE
51 ADXM 12B
incorporated
20
21 DYF9 E10
20
11 BF9 10
11 BF9 10
11 BF9 10
11 RF25 10
–
31 BT2N 12S
4 - 11 G480 11
–
11 SMX90 23
11 SM1A 44
13 - 18
50
11 BF16
11 BF16C
20
11 BF16
11 BF16C
11 RF25 23
–
14 - 23
45 FE
51 ADX 0017B
incorporated
25
21 DYF12 E15
25
11 BF12 10
11 BF12 10
11 BF9 10
11 RF25 15
–
31 BT2N 12S
4 - 11 G480 11
–
11 SMX90 23
11 SM1A 48
17 - 23
50
11 BF20 00
11 BF20C
25
11 BF20 00
11 BF20C
11 RF25 23
–
14 - 23
90 FE
51 ADX 0030B
incorporated
25
21 DYF12 E15
25
11 BF12 10
11 BF12 10
11 BF9 10
11 RF25 15
–
31 BT2N 12S
4 - 11 G480 11
–
11 SMX90 23
11 SM1A 48
17 - 23
50
11 BF25 00
11 BF25C
25
11 BF25 00
11 BF25C
11 RF25 23
–
14 - 23
90 FE
51 ADX 0030B
incorporated
32
21 DYF20 E23
32
11 BF20 00
11 BF20 00
11 BF12 10
11 RF25 23
–
31 BT2N 12S
4 - 11 G480 11
–
11 SMX90 25
11 SM2A 64
22 - 32
50
11 BF32 00
11 BF32C 00
40
11 BF32 00
11 BF32C 00
11 RF95 33
11 G260
20 - 33
90 FE
51 ADX 0030B
incorporated
40
21 DYF25 E23
40
11 BF25 00
11 BF25 00
11 BF16 10
11 RF25 23
–
31 BT2N 12S
4 - 11 G480 11
–
11 SMX90 25
11 SM2A 68
28 - 40
50
11 BF40 00
11 BF40C 00
45
11 BF40 00
11 BF40C 00
11 RF95 42
11 G260
28 - 42
120 FEE
51 ADX 0045B
incorporated
45
21 DYF25 E26
45
11 BF25 00
11 BF25 00
11 BF16 10
11 RF25 26
–
31 BT2N 12S
4 - 11 G480 11
–
11 SMX90 25
11 SM2A 72
36 - 45
50
11 BF50 00
11 BF50C 00
50
11 BF50 00
11 BF50C 00
11 RF95 50
11 G261
35 - 50
120 FEE
51 ADX 0045B
incorporated
63
21 DYF40 E42
63
11 BF40 00
11 BF40 00
11 BF25 00
11 RF95 42
11 G260
31 BT2N 12S
4 - 11 G480 11
–
11 SMX90 27
11 SM3A 84
45 - 63
50
11 BF65 00
11 BF65C 00
80
11 BF65 00
11 BF65C 00
11 RF95 65
11 G261
46 - 65
160 FEE
51 ADX 0060B
incorporated
375068
456083
557598
5980105
75100135
90125158
110150193
132180232
160220282
80
21 DYF50 E50
80
11 BF50 00
11 BF50 00
11 BF32 00
11 RF95 50
11 G261
31 BT2N 12S
4 - 11 G480 11
–
11 SMX90 29
11 SM3A 88
57 - 75
50
11 BF80 00
11 BF80C 00
100
11 BF80 00
11 BF80C 00
11 RF95 82
11 G261
60 - 82
180 FM
51 ADX 0075B
incorporated
100
21 DYF50 E50
100
11 BF50 00
11 BF50 00
11 BF32 00
11 RF95 50
11 G261
31 BT2N 12S
4 - 11 G480 11
–
11 SMX90 29
11 SM3A 92
70 - 90
50
11 BF95 00
11 BF95C 00
100
11 BF95 00
11 BF95C 00
11 RF95 95
11 G261
70 - 95
200 FM
51 ADX 0085B
incorporated
125
21 DYF65 E65
125
11 BF65 00
11 BF65 00
11 BF32 00
11 RF95 65
11 G261
31 BT2N 12S
4 - 11 G480 11
–
11 SMX90 29
11 SM3A 96
80 - 100
50
11 B115 00
125
11 B115 00
11 RF180 125
11 G372
75 - 125
250 FM
51 ADX 0110B
incorporated
160
21 DYF80 E82
160
11 BF80 00
11 BF80 00
11 BF50 00
11 RF95 82
11 G261
31 BT2N 12S
4 - 11 G480 11
–
11 SMX90 20
–
–
–
11 B145 00
160
11 B145 00
11 RF180 150
11 G372
90 - 150
315 FM
51 ADX 0142B
incorporated
200
21 NFY115 100
200
11 B115 00
11 B115 00
11 BF65 00
11 RF180 100
11 G372
31 BT2N 12S
1 - 11 G480 11
2 - 11 G350
–
–
–
–
11 B180 00
200
11 B180 00
11 RF180 200
11 G372
120 - 200
500 FMM
51 ADX 0190B
incorporated
250
21 NFY115 125
250
11 B115 00
11 B115 00
11 BF65 00
11 RF180 125
11 G372
31 BT2N 12S
1 - 11 G480 11
2 - 11 G350
–
–
–
–
11 B250 00
250
11 B250 00
11 RF400 250
11 G376
150 - 250
550 FMM
51 ADX 0245B
incorporated
315
21 NFY145 125
315
11 B145 00
11 B145 00
11 BF80 00
11 RF180 150
11 G372
31 BT2N 12S
1 - 11 G480 11
2 - 11 G350
–
–
–
–
11 B250 00
315
11 B250 00
11 RF400 300
11 G376
180 - 300
550 FMM
51 ADX 0245B
incorporated
315
21 NFY180 200
315
11 B180 00
11 B180 00
11 B115 00
11 RF180 200
11 G372
31 BT2N 12S
3 - 11 G350
–
–
–
–
–
11 B310 00
315
11 B310 00
11 RF400 300
11 G376
180 - 300
630 FMM
51 ADX 0310
B250
200270349
250340430
315430545
355445610
450600810
630840–
400
21 NFY250 250
400
11 B250 00
11 B250 00
11 B145 00
11 RF400 250
11 G376
31 BT2N 12S
3 - 11 G350
–
–
–
–
–
11 B400 00
400
11 B400 00
11 RF400 420
11 G376
250 - 420
900 F4M
51 ADX 0365
B310
500
21 NFY250 300
500
11 B250 00
11 B250 00
11 B145 00
11 RF400 300
11 G376
31 BT2N 12S
3 - 11 G350
–
–
–
–
–
11 B500 00
–
11 B500 00
–
–
–
900 F4M
51 ADX 0470
B400
630
21 NFY400 420
630
11 B400 00
11 B400 00
11 B250 00
11 RF400 420
11 G376
31 BT2N 12S
3 - 11 G350
–
–
–
–
–
11 B630 00
–
11 B630 00
–
–
–
1100 F4M
51 ADX 0568
B500
630
21 NFY400 420
630
11 B400 00
11 B400 00
11 B250 00
11 RF400 420
11 G376
31 BT2N 12S
3 - 11 G350
–
–
–
–
–
11 B630 00
–
11 B630 00
–
–
–
1250 F4M
51 ADX 0640
B500
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
51 ADX 0820
B630 1000
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
51 ADX 1200
B1250
125
21 DYF65 E65
125
11 BF65 00
11 BF65 00
11 BF32 00
11 RF95 65
11 G261
31 BT2N 12S
4 - 11 G480 11
–
11 SMX90 29
–
–
–
11 B115 00
125
11 B115 00
11 RF180 125
11 G372
75 - 125
280 FM
51 ADX 0125B
incorporated
Breaking capacityIcu at 400V - 50kA
11 SM1A 40 9-14A11 SM1A 44 13-18A11 SM1A 48 17-23A11 SM1A 52 20-25A
Breaking capacityIcu at 400V - 100kA for 0.1-10A, 25kA for 9-25kA
Potere d’interruzioneIcu a 400V = 100kA (0,1÷10A), 25kA (9÷25A)per montaggio in centralini modulari
Breaking capacityIcu at 400V - 50kA
11 SM2A 64 22-32A11 SM2A 68 28-40A11 SM2A 72 36-45A11 SM2A 76 40-50A
Breaking capacityIcu at 400V - 50kA
11 SM3A 84 45-63A11 SM3A 88 57-75A11 SM3A 92 70-90A11 SM3A 96 80-100A
11 B11511 B14511 B18011 B25011 B31011 B40011 B50011 B630
11 B630 100011 B125011 B1600
160250275350450550700 800
100012501600
110150185265320420520630–––
TypeRated current
at 400VA (AC1 ≤40°C) A (AC3 ≤55°C)
▲ RANGES AVAILABLEFOR MOTOR PROTECTIONCIRCUIT BREAKERS
The recommendedrange is indicatedin the table above.The following areother available types:
11 RF9 015 0.09-0.15A11 RF9 023 0.14-0.23A11 RF9 033 0.2-0.33A11 RF9 05 0.3-0.5A11 RF9 075 0.45-0.75A11 RF9 1 0.6-1A11 RF9 1V5 0.9-1.5A11 RF9 2V3 1.4-2.3A11 RF9 33 2-3.3A11 RF9 5 3-5A11 RF9 75 4.5-7.5A11 RF9 10 6-10A11 RF9 15 9-15A
For contactorsBF9, BF12, BF16, BF20, BF25, BF32 and BF40
11 RF25 015 0.09-0.15A11 RF25 023 0.14-0.23A11 RF25 033 0.2-0.33A11 RF25 05 0.3-0.5A11 RF25 075 0.45-0.75A11 RF25 1 0.6-1A 11 RF25 1V5 0.9-1.5A11 RF25 2V3 1,4-2.3A11 RF25 33 2-3.3A11 RF25 5 3-5A11 RF25 75 4.5-7.5A11 RF25 10 6-10A11 RF25 15 9-15A11 RF25 23 14-23A11 RF25 26 17-26A
11 RF95 23 14-23A11 RF95 33 20-33A11 RF95 42 28-42A11 RF95 50 35-50A11 RF95 65 46-65A11 RF95 82 60-82A11 RF95 95 70-95A
For contactorsB115, B145, B180, B250, B310 and B400
11 RF180 100 60-100A11 RF180 125 75-125A11 RF180 150 90-150A11 RF180 200 120-200A
11 RF400 250 150-250A11 RF400 300 180-300A11 RF400 420 250-420A
❖ RANGES AVAILABLEFOR THERMALOVERLOAD RELAYS
The recommendedrange is indicatedin the table above.The following areother available types:
Special 2NO+2NC power pole contactors
Special 4NC power pole contactor
Special contactors for power factor correction
Four-pole contactors
Control relays
Other types:
Motor protection circuit breaker with three-pole contactor
Three-pole contactor with thermal overload relay
Assembled star-delta starter, open frame
Soft starters
Star-delta starter components, to be customer assembled
➊ Replace with: 10 to obtain contactor with one normally open auxiliary contact(NO) or 01 to obtain contactor with one normally closed auxiliary contact (NC).
➋ Complete order code with the coil voltage digit or with the voltage digit fol-lowed by 60 if 60Hz. The standard voltages are as follows:-- 50/60Hz 024-048-110-220-220/230-230-240-380-400-415V-- 60Hz 024-048-110-120-220-230V.
➌ Complete order code with coil voltage digit. Standards voltages are: 012-024-048-060-110-125-220V.
➍ Complete order code with the coil voltage digit (if 50Hz) or with the voltage digit followed by 50-60 (if 50/60Hz frequency) or with the voltagedigit followed by 60 (if 60Hz).The standard voltages are as follows:-- 50Hz 24-48-110-220-230-240-380-400-415V-- 50/60Hz 24-48-110-220-220/230-230-240-380-380/400-415V-- 60Hz 24-48-110-120-220-230V.
➎ The electromagnet of the contactor can be powered indifferently in AC or DC.Complete the order code only with the digit of the coil voltage. For coils:110/125V indicate 110, 220/240V indicate 220, 380/415V indicate 380,440/480V indicate 440. Standard voltages are: 24-48-60-110/125-220/240-380/415-440/480V (24V voltage is not possible for B500-B630 1000).Other voltages available on request.
➏ Complete the order code with the digit of the coil voltage. Standard voltagesare: 12-24-48-60-110-125-220VDC.
➐ Complete the order code with the digit of the coil voltage:48 (24/48VAC/DC) - 110 (24VAC/DC - 110-125VAC)220 (24VAC/DC - 220-240VAC) - 380 (24VAC/DC - 380-415VAC)440V (24VAC/DC - 415-440VAC).
➑ Complete order code with the coil voltage digit (if 50Hz) or with thevoltage digit followed by 60 (if 60Hz).The standard voltages are as follows:– 50Hz 24-48-110-220-230-240-380-400-415VAC– 60Hz 24-48-110-120-220-230VAC.
Breakerwithcontactor
Contactorwith thermalrelay
Star-deltastarter
Softstarter
11 BF9011 BF1211 BF1611 BF2011 BF2511 BF3211 BF4011 BF5011 BF6511 BF8011 BF95
2525254040556090
110125125
912162025324050658095
TypeRated current
at 400VA (AC1 ≤40°C) A (AC3 ≤55°C)
11 BG0611 BG0911 BG12
162020
69
12
TypeRated current
at 400VA (AC1 ≤40°C) A (AC3 ≤55°C)
■
1 2
1 3
1 2
1 3
1 2
1 3
1 2
1 3
1 2
1 3
1 2
1 3
1 2
1 3
1 1 4
1 6
1 4
1 6
1 4
1 6
1 4
1 6
1 4
1 6
1 4
1 6
1 4
1 6
1 4
1 6
4
1 6
4
1 6
4
6
4
6
4
6
4
6
4
6
45 5 5 5 5 5 5 5 5 5 5
6
2
1 3
1 2
1 3
1 2
1 3
1 2
1 3
1 2
1 3
1 2
1 3
1 1 4
1 6
1 4
1 6
1 4
1 6
1 4
1 6
4
4
4
4
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
5
5
4
5
5
4
5
5
4
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 8 8 8 8 8 8 8 8
1 4
1 6
1 4
1 6
1 4
1 6
1 4
1 6
4
1 6
4
1 6
4
6
4
6
4
6
4
6
4
6
45 5 5 5 5 5 5 5 5 5 5
6
2
1 3
Motor protection circuit breakers Add-on blocks and accessories
Soft starters
Thermal overload relaysContactors Add-on blocks and accessories
G418...
G218
G280
G269 1
G223
G483
G481...G482...
G318...G319...G322...
G231
BA135
G477...G479...
BA126 2
BA126 1
3958...
G232
BA235
CF4BF9BF12BF16
BF20BF25
BF32BF40❶
G281
BF50BF65BF80BF95
G285
BA435
G271
G269 2G222
G272
G485...G486...G487...
G484...
G480...
G265
G270
G230
1
3L2
1L1
5L3
3
5
BF50BF65BF80BF95
G372G373G375G376
G233
G262
G261
G260
G258
BF32BF40
BF20BF25
BF9BF12BF16
BG06...BG09...BG12...
G430G291
RF9
RF25
RF95
G244
G228
RF180RF400
G370
G371
G350G354
G360 (B115)G361 (B145-B180)
G362 (B250)G363 (B310-B400)
G527 (B500 00)G528 (B500 4 00)G529 (B630 00)G530 (B630 4 00)
G356...
G355
BA1846(B500-B630)
BA1845(B500-B630)
B500B630B630 1000
B250B310B400 BA1721
BA1720
BA126 2
BA126 1
3958
BA1595 BA1594B115B145B180
TEST
Lovato
L
SMX90 03
SM1...TEST
Lovato
L
SMX90 10
SMX90 01SMX90 02
International Sales Department:Tel. +39 035 4282281Fax +39 035 4282400
BGX50 00❶
SMX90 22
for SM1 types
LOVATO ELECTRIC S.P.A.CONTROL SOLUTIONSFOR INDUSTRY
VIA DON E. MAZZA, 1224020 GORLE (BG)ITALY
Tel.: +39 035 4282111Fax: +39 035 4282200E-mail [email protected]
www.LovatoElectric.com
100% electricity
electricfor SM2 and SM3 types
Order code Characteristics Q.ty Wtper [kg]pkg
Order code Characteristics Q.ty Wtper [kg]pkg
ADD-ON AUXILIARY CONTACTS.11 SMX11 20 Front mount 2NO 10 0.01011 SMX11 11 Front mount 1NO+1NC 10 0.01011 SMX12 11 Side mount 1NO+1NC 10 0.04511 SMX12 20 Side mount 2NO 10 0.04511 SMX12 02 Side mount 2NC 10 0.04511 SMX13 11 Side mount indicator 10 0.045
contacts 1NO+1NCUNDERVOLTAGE TRIP RELEASES.11 SMX14 BC 110VAC 50/60Hz 10 0.10011 SMX14 CL 230VAC 50/60Hz 10 0.10011 SMX14 EA 400VAC 50/60Hz 10 0.10011 SMX15 CL 230VAC 50/60Hz 5 0.100
with early-make contacts11 SMX15 EA 400VAC 50/60Hz 5 0.100
with early-make contactsSHUNT TRIP RELEASES.11 SMX16 AF 24VAC 50/60Hz 5 0.10011 SMX16 BC 110VAC 50/60Hz 5 0.10011 SMX16 CL 230VAC 50/60Hz 5 0.10011 SMX16 EA 400VAC 50/60Hz 5 0.100THREE-PHASE CONNECTION BUSBARS 45MM SPACING.11 SMX90 32 For 2 breakers without 10 0.027
side-mount contacts11 SMX90 33 For 3 breakers without 10 0.048
side-mount contacts11 SMX90 34 For 4 breakers without 10 0.068
side-mount contacts11 SMX90 35 For 5 breakers without 10 0.090
side-mount contactsTHREE-PHASE CONNECTION BUSBARS 54MM SPACING.11 SMX90 42 For 2 breakers complete with 10 0.034
side-mount contacts11 SMX90 43 For 3 breakers complete with 10 0.054
side-mount contacts11 SMX90 44 For 4 breakers complete with 10 0.078
side-mount contacts11 SMX90 45 For 5 breakers complete with 10 0.103
side-mount contactsTERMINAL BLOCK FOR BUSBAR SUPPLY.11 SMX90 30 –– 10 0.033SAFETY COVER.11 SMX90 31 For unused 10 0.005
busbar terminalsPADLOCKABLE DOOR INTERLOCK HANDLE.11 SMX18 14 Red/yellow colour. 1 0.600
3 padlocks max11 SMX18 15 Black colour. 3 padlocks max 1 0.600
PADLOCKABLE ATTACHMENT FOR OPERATING LEVER.11 SMX18 10 3 padlocks max Ø 5mm 10 0.021ADJUSTER SEALING KIT.11 SMX18 12 –– 10 0.003SM1-CONTACTOR CONNECTION.11 SMX90 01 For BG - BF9... to BF16 10 0.012
(set of 3 cables)11 SMX90 02 For BF20 to BF40 10 0.025
(set of 3 cables)11 SMX90 03 For BG 10 0.020
(rigid connecting kit)11 SMX90 04 For BF9 to BF16 10 0.030
(rigid connecting kit)SURFACE MOUNT ENCLOSURES.11 SMX17 10 IP40. 100mm wide 10 0.29511 SMX17 11 IP40. 85mm wide 10 0.250FLUSH MOUNT ENCLOSURE.11 SMX17 20 IP40. 100mm wide 10 0.230ACCESSORIES FOR ENCLOSURES.PADLOCKABLE ROTARY ACTUATOR.11 SMX17 30 ➋ IP65. For SMX17 10 and 10 0.400
SMX17 20 enclosures 11 SMX17 35 ➋ IP65. Red-yellow colour. 10 0.110
For SMX17 10 and SMX17 20 enclosures
ACTUATOR WITH EMERGENCY STOP BUTTON.11 SMX17 40 ➋ IP65. For SMX17 11 enclosure 10 0.100NEUTRAL CONNECTION.11 SMX17 50 For SMX17 10 and SMX17 20 10 0.020PILOT LIGHT.23 NEONV➊ V Green 10 0.00623 NEONR➊ V Red 10 0.006IP65 MEMBRANE COMPLETE WITH RIM.11 SMX17 45 For SMX17 11 enclosure 10 0.010
Order code Characteristics Q.ty Wtper [kg]pkg
ADD-ON AUXILIARY CONTACTS.11 SMX20 11 Front mount 10 0.016
1 changeover11 SMX21 11 Front mount 10 0.018
1NO+1NC11 SMX22 11 Side mount 1 0.046
1NO+1NC11 SMX22 20 Side mount 2NO 1 0.04611 SMX22 02 Side mount 2NC 1 0.04611 SMX23 11 Side mount indicator 1 0.092
contacts (1NO+1NC)for thermal trip and (1NO+1NC) for magnetic trip
UNDERVOLTAGE TRIP RELEASES.11 SMX24 BC 110VAC 50/60Hz 1 0.13511 SMX24 CL 230VAC 50/60Hz 1 0.13511 SMX24 EA 400VAC 50/60Hz 1 0.13511 SMX25 CL 230VAC (50/60Hz) 1 0.135
with early-make contacts11 SMX25 EA 400VAC (50/60Hz) 1 0.135
with early-make contactsSHUNT TRIP RELEASES.11 SMX26 AF 24VAC 50/60Hz 1 0.13511 SMX26 BC 110VAC 50/60Hz 1 0.13511 SMX26 CL 230VAC 50/60Hz 1 0.13511 SMX26 EA 400VAC 50/60Hz 1 0.135PADLOCKABLE DOOR INTERLOCK ROTARY ACTUATOR.11 SMX28 10 IP65. 3 padlocks max 1 0.100
for mini-contactors BG for contactors Bfor contactors BF
Order code Characteristics Max Q.ty Wtqty per per [kg]contactor pkg
➊ Complete order code with the required alphanumeric symbol.
➊ The contacts can also be fitted on B type contactors usingthe adapter G358.
➋ The normally closed contact is late breaking.➌ High conductivity contacts.➍ With Faston terminals.
AUXILIARY CONTACTS WITH SCREW TERMINALS.11 BGX10 20 2NO 1 10 0.02111 BGX10 11 1NO + 1NC 1 10 0.02111 BGX10 02 2NC 1 10 0.02111 BGX10 40 4NO 1 10 0.02811 BGX10 31 3NO + 1NC 1 10 0.02811 BGX10 22 2NO + 2NC 1 10 0.02811 BGX10 13 1NO + 3NC 1 10 0.02811 BGX10 04 4NC 1 10 0.028MECHANICAL INTERLOCK.11 BGX50 00 –– 1 10 0.008QUICK CONNECT NOISE FILTER.11 BGX77 048 ≤48VAC/DC 1 10 0.007
(Varistor)11 BGX77 125 48-125VAC/DC 1 10 0.007
(Varistor)11 BGX77 240 125-240VAC/DC 1 10 0.007
(Varistor)11 BGX78 225 ≤225VDC 1 10 0.007
(Diode)11 BGX79 048 ≤48VAC 1 10 0.007
(Resistor-Condenser)11 BGX79 125 48-125VAC 1 10 0.007
(Resistor-Condenser)11 BGX79 240 125-240VAC 1 10 0.007
(Resistor-Condenser)11 BGX79 415 240-415VAC 1 10 0.007
(Resistor-Condenser)PARALLEL BRIDGES11 G323 2 poles 10 0.00911 G324➊ 2 poles 10 0.00911 G325 4 poles 10 0.01411 G326➊ 4 poles 10 0.014
for relays RF
Order code Characteristics Q.ty Wtper [kg]pkg
SET OF LINKS FOR DIRECT CONTACTOR MOUNTING11 G430 ➊ RF...95 on BF20-BF25 10 0.02711 G291 ➋ contactor BF20 40-BF25 40 10 0.02111 G260 BF32-BF40 10 0.02611 G261 BF50÷BF95 10 0.04811 G372 RF...180 on B115-B145-B180 1 0.08211 G373 contactor B250-B310-B400 1 0.10011 G375 RF...400 on B145-B180 1 0.10311 G376 contactor B250-B310-B400 1 0.165PROTECTION SHROUDS FOR POWER TERMINALS.11 G258 ➌ RF95 c/w G260 links 10 0.00311 G262 ➌ RF95 c/w G261 links 10 0.00411 G361 RF...180 1 0.02611 G363 RF...400 1 0.046INDEPENDENT MOUNTING.SCREW FIXING OR 35mm DIN RAIL (EN 50022) MOUNTING.11 G230 RF25 10 0.04211 G270 RF95 10 0.094ELECTRICAL RESET.11 G228➍ All types 5 0.058SEALING DEVICE.11 G233 All types 1 0.002ELECTRIC BUTTON NO.11 G244 All types 10 0.011MARKING ELEMENT.11 RB6 All types 100 0.001ALPHANUMERIC SYMBOLS.3958❺ All types 100 0.002
Order code Characteristics Max Q.ty Wtqty per per [kg]contactor pkg
INSTANTANEOUS AUXILIARY CONTACTSWITH FRONT CENTRE MOUNTING➊ .11 G480 11 1NO + 1NC 2 10 0.02411 G480 20 2NO 2 10 0.02411 G480 1001 make before break ➋ 2 10 0.02411 G484 20➌ 2NO 1 5 0.03511 G484 11➌ 1NO + 1NC 1 5 0.03511 G484 02➌ 2NC 1 5 0.03511 G484 30➌ 3NO 1 5 0.03911 G484 21➌ 2NO + 1NC 1 5 0.03911 G484 12➌ 1NO + 2NC 1 5 0.03911 G484 03➌ 3NC 1 5 0.039INSTANTANEOUS AUXILIARY CONTACTSWITH FRONT LATERAL MOUNTING.11 G218➍ 1NO or 1NC revers. 2 10 0.01111 G418 10 1NO 2 10 0.01411 G418 10A 1EM 2 10 0.01411 G418 01 1NC 2 10 0.01411 G418 01D 1LB 2 10 0.01411 G481 20➍ 2NO 2 10 0.01311 G481 11➍ 1NO + 1NC 2 10 0.01311 G481 02➍ 2NC 2 10 0.01311 G482➌➍ Changeover contact 2 10 0.013SUPPORT FOR AUXILIARY CONTACT SIDE MOUNTING.11 G280 for G218 2 10 0.00811 G483 for G481 and G482 2 10 0.010DELAYED AUXILIARY CONTACTS 1NO + 1NC(PNEUMATIC OPERATION) ON ENERGISATION➊ .11 G485 3 3 s 1 1 0.04011 G485 6 6 s 1 1 0.04011 G485 15 15 s 1 5 0.04011 G485 30 30 s 1 5 0.04011 G485 60 60 s 1 5 0.04011 G485 120 120 s 1 1 0.040DELAYED AUXILIARY CONTACTS 1NO + 1NC(PNEUMATIC OPERATION) ON DE-ENERGISATION➊ .11 G486 3 3 s 1 1 0.04011 G486 6 6 s 1 1 0.04011 G486 15 15 s 1 5 0.04011 G486 30 30 s 1 5 0.04011 G486 60 60 s 1 5 0.04011 G486 120 120 s 1 1 0.04011 G487 70 ms 1 1 0.040
➊ Replace with the digit of the voltage (if 50 or 60Hz) and withthe letter C followed by the digit of the voltage (if DC).Standard voltages are:50/60Hz 24V - 48V - 110/125V - 220/240V - 380/415VDC 12V - 24V - 48V - 110/125V - 220/240V
➋ The G477 and G479 filters can only be fitted on BF9-BF25 andCF4 contactors having 3-terminal coil.
Order code Characteristics Max Q.ty Wtqty per per [kg]contactor pkg
MECHANICAL LATCH.11 G222 ➊ for CF4, BF9-BF40 1 1 0.059
(BF40 three-pole only)11 G272 ➊ BF40 40, BF50-BF95 1 1 0.059MECHANICAL INTERLOCKS.11 G223 per CF4, BF9-BF40 1 10 0.00511 G269 1 (BF40 three-pole only) 1 10 0.02311 G269 2 BF40 40, BF50-BF95 1 10 0.028NOISE FILTERS (FASTON TERMINALS).11 G318 48 ≤48VAC/DC (Varistor) 10 0.00811 G318 125 48-125VAC/DC (Varistor) 10 0.00811 G318 240 125-240VAC/DC (Varistor) 10 0.00811 G318 415 240-415VAC/DC (Varistor) 10 0.00811 G319 225 ≤225VDC (Diode) 10 0.00811 G322 48 ≤48VAC (Resistor-Condenser) 10 0.00811 G322 220 48-240VAC (Resistor-Condens.) 10 0.00811 G322 380 240-415VAC (Resistor-Condens.) 10 0.008FILTER SUPPORT.11 RE244 For 35 mm DIN rail (EN 50022) 10 0.004QUICK CONNECT NOISE FILTERS ➋ .11 G477 048 ≤48VAC (Varistor) 10 0.01011 G477 125 48-125VAC (Varistor) 10 0.01011 G477 240 125-240VAC (Varistor) 10 0.01011 G477 415 240-415VAC (Varistor) 10 0.01011 G479 48 ≤48VAC (Resistor-Condenser) 10 0.01011 G479 125 48-125VAC (Resistor-Condens.) 10 0.01011 G479 240 125-240VAC (Resistor-Condens.) 10 0.01011 G479 415 240-415VAC (Resistor-Condens.) 10 0.010
TEST
Lovato
L
SMX14... 1
SMX16... 1
SMX15... 1SMX11... 2
SMX13...
SMX12...
➊ Only one add-on block can be fixed on the left side of the breaker.
Mounting position
TEST
Lovato
L
SMX90 03
SM1...TEST
Lovato
L
SMX90 10
SMX90 01SMX90 02
Rigid connecting kit for SM1breaker with BG contactor
Adapter plate and connections forSM1 breaker with BG or BF9 toBF40 contactor
Lovato
L
SMX22...
SMX23 11
SMX20 11SMX21 11
SMX24...SMX25...SMX26...
Mounting position
Order code Characteristics Max Q.ty Wtqty per per [kg]contactor pkg
INSTANTANEOUS AUXILIARY CONTACTS.11 G350➊ 2NO+1NC or 4 1 0.067
NO+2NC reversible11 G354➊ 1NO+1NC 4 1 0.065CONTACT BLOCK ADAPTER11 G358 To fit auxiliary contacts 4 5 0.035
G480, G484, G485,G486 and G487 types,on B115-B630 1000contactors
MECHANICAL INTERLOCK.11 G355➋➌ Side by side 1 1 0.02511 G356 1➋ One on top of other 1 1 0.10411 G356 2➋ One on top of other 1 1 0.11011 G356 3➋ One on top of other 1 1 0.11611 G356 4➋ One on top of other 1 1 0.12211 G356 5➋ One on top of other 1 1 0.12411 G356 6➍ One on top of other 1 1 0.134MECHANICAL LATCH.11 G495➎➏➐ For B115-B630 1 1 0.716POWER TERMINAL PROTECTION.11 G360➑ For contactor B115 1 0.02611 G361➑ For contactors B145-B180 1 0.02611 G363➑ For contactors B250-B310-B400 1 0.04711 G527 For contactor B500 1 0.23811 G528 For contactor B500 4 1 0.26511 G529 For contactor B630 1 0.25011 G530 For contactor B630 4 1 0.2903 POLE STAR CONNECTING BARS.11 BA1595 For B115-B145-B180 1 0.08211 BA1721 For B250-B310-B400 1 0.14011 BA1846 For B500-B630 1 0.3402 POLE BARS FOR PARALLEL ARRANGEMENT.11 BA1594 For B115-B145-B180 1 0.08911 BA1720 For B250-B310-B400 1 0.14011 BA1845 For B500-B630 1 0.320TERMINAL ADAPTER.11 G370 To transform Faston terminals 10 0.003
of auxiliary contacts and coils into screw terminals
11 G371 To transform both 5 0.012coil Faston terminalsinto screw terminals
MARKING ELEMENTS.11 BA126 1 Label for alphanumeric symbols 100 0.00111 BA126 2 Label for writing 100 0.0013958 ➒ Alphanumeric symbols 100 0.002
➊ For 3-pole contactors, BF50-BF95 types only.N.B. Two pieces are required per contactor.
➋ Replace with the required alphanumeric symbol
➊ Only for contactors B115-B145-B180-B250-B310-B400-B500-B630-B630 1000.
➋ Not suitable for B630 1000, B1250, B1600.➌ For use with three-pole B630 1000, contact our Customer
Service (Tel. +39 035 4282422).➍ To interlock two contactors B1250 or B1600, it is imperative to
use two pieces of type G356 6, one fixed on the left side andthe other on the right.
➎ Replace with the digit of the voltage (if 50 or 60 Hz) or with theletter C followed by voltage (if DC). The standard voltages are:– 50/60 Hz
48V - 110/125V - 220/240V - 380/415V - 440/480V– DC
48V - 110/125V - 220/240V - 380/415V - 440/480V➏ It can be mounted only in contactors if predisposed for it.➐ Except for B310 and B310 4.➑ Provided for one pole terminal only. Example: For three-pole
contactors, purchase 3 pieces for the upper terminals only or 6pieces for all upper and lower terminals.
➒ Replace with the required alphanumeric symbol.
Order code Characteristics Q.ty Wtper [kg]pkg
POWER TERMINAL SHROUD.11 G265➊ IP20 protection 10 0.011PARALLEL BRIDGES.11 BA135 2 poles (for BF9-BF16) 10 0.00111 BA235 2 poles (for BF20-BF40) 10 0.00311 BA435 3 poles (for BF50-BF95) 10 0.029ENLARGED TERMINALS.11 G231 1-6 mm2 (for BF9-BF16) 12 0.00811 G232 1-10 mm2 (for BF20-BF25) 12 0.01711 G281 1-35 mm2 (for BF32-BF40) 10 0.09011 G271 1-50 mm2 (for BF50-BF95) 10 0.130AUXILIARY TERMINAL.11 G285 for BF50-BF95 8 0.008MARKING ELEMENTS.11 BA126 1 Label for alphanumeric symbols 100 0.00111 BA126 2 Label for writing 100 0.0013958➋ Alphanumeric symbols 100 0.002
Mounting position
Mounting position
➊ Side-mount auxiliary contacts can not be fittedon BF40 22 contactors
Mounting position
Electromechanical startersStarter assembly accessories
Order code Characteristics Q.ty Wtper [kg]pkg
11 SMX90 01 Set of 3 connecting cables 10 0.012cables for SM1 breaker with BG, BF9, BF12 or BF16contactor
11 SMX90 02 Set of 3 connecting cables 10 0.025for SM1 breaker with BF20, BF25, BF32 or BF40 contactor
11 SMX90 03 Rigid connecting kit for SM1 10 0.020breaker with BG mini-contactor
11 SMX90 04 Rigid connecting kit for SM1 10 0.030with BF9-BF16 connection
11 SMX90 10 Adapter plate for 1 0.052direct-on-line starter composed by SM1 breaker and BG or BF9-BF40 contactor
11 SMX90 12 Adapter plate for reversing 1 0.078contactor assembly composedby SM1 breaker and BG or BF9-BF25 contactors
11 SMX90 14 Adapter plate for star-delta 1 0.104starter composed by SM1breaker and 45mm wide contactors (BF9-BF25)
11 SMX90 18 35mm DIN rail (EN 50022) 1 0.088for cable bypass of contactorused with SMX90 14 plate
11 SMX90 19 35mm DIN rail extension for 1 0.00455mm wide contactors
11 SMX90 20 Connecting kit for star-delta 1 –starter composed by BF50-BF95 (line-delta contactors)and BF50-BF95 (star contactor)
11 SMX90 21 Connection kit for wye-delta 1 14.00starter with BG mini-contactors
11 SMX90 22 Rigid connecting kit for 1 0.026reversing contactor assemblycomposed by mini-contactors BG ➊➋
11 SMX90 23 Rigid connecting kit for 1 0.050star-delta starter composed byBF9, BF12 or BF16 contactors (suitable for contactorsmounted side by side; not suitable for SMX90 14 plate)
11 SMX90 24 Rigid connecting kit for 1 0.047reversing contactor assmblycomposed by BF9, BF12 or BF16 contactors➊➋
11 SMX90 25 Connecting kit for star-delta 1 –starter composed by BF20-BF25 (line-delta contactors)and BF9-BF16 (star contactor)
11 SMX90 26 Rigid connecting kit for two 1 16.00BF20 or BF25 contactors➊➋
11 SMX90 27 Connecting kit for star-delta 1 –starter composed by BF32-BF40 (line-delta contactors)and BF20-BF25 (star contactor)
11 SMX90 28 Rigid connecting kit for two 1 20.00BF32 or BF40 contactors➊➋
11 SMX90 29 Connecting kit for star-delta 1 –starter composed by BF50-BF95 (line-delta contactors)and BF32-BF40 (star contactor)
Remote keypad and control software
Order code Characteristics Q.ty Wtper [kg]pkg
51 ADX TAST Remote keypad 1 0.35096x96mm,2x16 backlit LCD, 208-240VACsupply c/w 3m longconnecting cable
31 PA 96X96 Protective cover 1 0.077(IP54)
51 ADX SW PC-ADX remote control 1 0.550software complete witha set of connecting cables for communications viaRS-232 port, modemor GSM modem
Mounting position
➊ For BF20 40 - BF25 40 and DC types.
Combinations
Connections for reversing contactorassembly with BG contactors
G223
G269 1
SMX90 24
Connections for reversing contactorassembly with BF9-BF16 contactors
SMX90 23
Connections for star-deltastarters with BF9-BF16contactors
Adapter plate for star-delta starter withSM1 breaker and BF9-BF25 contactors
➊ Contactors with one NC auxiliary contact, 01type, are usually used.
➋ The relay can not be directly mounted on thecontator. Use the RF25 type and the G230 independent mounting base.
Motor protectionand control
Planet-SWITCHPlanet-SWITCHPlanet-SWITCHPlanet-SWITCHPlanet-SWITCHPlanet-SWITCH
Planet-DIN
Planet-LOGIC
Planet-DIN
Planet-LOGIC
Planet-DIN
Planet-LOGIC
Planet-DIN
Planet-LOGIC
Planet-DIN
Planet-LOGIC
Planet-DIN
Planet-LOGIC
PD31
GB
07 0
2
➊ Complete with required voltage.Available voltages: 24-110-220-380VAC.
➋ The device obtained with this actuator is notsuitable for isolation per IEC/EN 60947-2 standars.
SMX14... ➊
SMX16... ➊
SMX15... ➊SMX11...
SMX13...
SMX12...
SM1...
SMX90 03
SMX90 10
SMX90 01SMX90 02
SMX22...
SMX23 11
SMX24...SMX25...SMX26...
SMX20 11SMX21 11
SM1...
SMX90 03
SMX90 10
SMX90 01SMX90 02
B115B145B180
G350G354
G370
G371
G360 (B115)G361 (B145-180)
G363 (B250-310-400)
G527 (B500 00)G528 (B500 4 00)G529 (B630 00)G530 (B630 4 00)
B500B630B630 1000
B250B310B400
BA1595 BA1594
BA126 1
3958
BA126 2
BA1721
BA1720
G356...
G355
BA1846(B500-B630)
BA1845(B500-B630)
BF9BF12BF16
BF20BF25
BF32BF40 BF50
BF65BF80BF95
B115B145B180B250B310B400
G372G373G375G376
G261
G258
G270
G262
G233
RF180RF400
3958...
G244
G228
RF95
RF25
G230
RF9
G260
G430G291
BG06...BG09...BG12...
RB6
TEST
Lovato
L
SMX90 14
SMX90 19
SMX90 01SMX90 02
SMX90 18
SMX90 14
SMX90 18
SMX90 01SMX90 02
SMX90 19
SMX90 23
SMX90 22
BGX50 00
SMX90 24
G223
G269 1
G480...
G484...
G485... - G486... - G487...
G371
G480...
G358
➊ G430 can be used only for connection between RF...95 andBF20 00, BF25 00.
➋ G291 can be used only for connection between RF...95 andBF20 40, BF25 40, BF25C 40, BF20C 10, BF20C 01, BF25C 10,BF25C 01.
➌ Front IP20 protection is warranted to contactor-thermal relayconnections.
➍ Replace with voltage digit.Standard voltages are: 24V - 48V - 110/125V - 220/240V -380/415V (50/60Hz).
➎ Replace with the required alphanumeric symbol.
100% electricity
BG00...BG06...BG09...BG12...
BGX10 40BGX10 31BGX10 22BGX10 13BGX10 04
BGX50 00
BGX77...BGX78 225BGX79...
BGX10 40BGX10 31BGX10 22BGX10 13BGX10 04
BGX10 10BGX10 11BGX10 02 BGX77...
BGX78 225BGX79...
BGX10 20BGX10 11BGX10 02
BGX10 40BGX10 31BGX10 22BGX10 13BGX10 04
BGX77...BGX78 225BGX79...
BGX10 20BGX10 11BGX10 02
G323
G324
G325
G326