* Highest performance and reliability using DSP (Digital Signal Processor)* SPWM (Sinewave Pulse Width Modulation) and IGBT to handle even the most difficult industrial applications* User-friendly interface and multi-functional display allowing access to a variety of parameters
41.
DS10KC33/ DS15KC33/ DS22.5KC33/ DS30KC33/ DS45KC33/ DS60KC33/DS80KC33/ DS100KC33/ DS120KC33
* DSC33 45-120K
* DSC33 10-30K
Durable Series For data centers and missioncritical systems
Energy Saving :With such high efficiency, you will save on energy consumption. This ensures lower operation costs and faster returns on your investments.
Topology:Double ConversionRating:10KVA to 120KVAVoltage:208V/120V,380V/220V
Applications:* Industrial* Medical* ISP/ASP/POP* Servers* Data Centers* Telecommunications
Front Panel
DSC10-30KC33
UPS Business
UPS Business
DSC45-120KC33
Line InteractiveUPS Series
On-Line UPSSeries
Stabilizer Series
NetworkingSeries
Inverter Series Surge Series Power Storage Series
Standby UPSSeries
42.
DS10KC33/ DS15KC33/ DS22.5KC33/ DS30KC33/ DS45KC33/ DS60KC33/DS80KC33/ DS100KC33/ DS120KC33
Durable Series For data centers and missioncritical systems
Model Name DS10KC33 DS15KC33 DS22.5KC33 DS30KC33 DS45KC33 DS60KC33 DS80KC33 DS100KC33 DS120KC33TopologyOn-battery output WaveformMaximum Capacity 10KVA / 8KW 15KVA / 12KW 22.5KVA / 18KW 30KVA / 24KW 45KVA / 36KW 60KVA / 48KW 80KVA / 64KW 100KVA / 80KW 120KVA / 96KWINPUTNominal Input voltageNominal Input PhaseNominal Input FrequencyInput Voltage Rangeinput ProtectionRegulation styleEfficiency of rectifierTotal EfficiencyOUTPUTNominal Output VoltageNominal Output PhaseFrequencyFrequency regulationRange of phase lockRange of lock releasedRange of lock backCrest FactorTotal Harmonic DistortionOutput Voltage RegulationStart on batteryAuto RestartTransient stateSTATIC SWITCHTransfer way
Transfer time
EfficiencyCHARGERVoltageCurrentCharging periodUTILITYBattery typeBackup timeNoisePROTECTION
Overload Protection
Short Circuit ProtectionENVIRONMENTALOperation TemperatureStorage TemperatureAmbient operation
Dimensions (Physical / Packing) (in)(L×W×H) (mm)
31.5×43.3×70.9 / 36.2×48.0×79.1800×1100×1800 / 920×1220×2010
Weight (Net / Gross) (lbs) (kg)
733.5 / 817.2333 / 371
755.5 / 839.2343 / 381
759.9 / 865.6345 / 393
907.5 / 1013.2412 / 460
1198.2 / 1418.5544 / 644
1389.9 / 1610.1631 / 731
1656.4 / 1881.1752 / 854
1924.7 / 2153.9873 / 977
2403.1 / 2579.41090 / 1170
Dimensions (Physical / Packing) (in)(L×W×H) (mm) TBD
Weight (Net / Gross) (lbs) (kg)
940.5 / 1024.2427 / 465
1006.6 / 1112.3457 / 505
1196 / 1301.8543 / 591
1616.7 / 1837734 / 834
2830.8 / 2998.31284 / 1360
3073.3 / 3240.81394 / 1470 TBD
Depending on type of batteries< 60dBA from the surface of 1m away
Bypass to inverter 0mSNormal state, inverter to bypass 0mS
> 99%
DC410VCurrent can be adjusted at 1A, 2A, 3A, 5A, 10A, 15A, 20A, 30A automatically
Return to 90% from 100% exhausted battery within 8 hours (depending on type of batteries)
Battery Pack with 12V x 30 pcs
When inverter and utility are synchronized at same phase and voltage, bypass
Yes
Related voltage ±1%Yes
>±5 Hz±3 Hz
3:1Less 3% linear load
No Fuse breaker
50Hz/60Hz±0.1%±5 Hz
Sine WaveDouble Conversion
3 Phase 3 wire / 3 Phase 4 wire and ground
380V/220V or 208V/120V
380V / 220V or 208V / 120V
3 phase 6 pulses or 12 pulses (optional)>97%
Related voltage ±20 %50Hz / 60Hz Auto-sensing
>85%
380V / 220V34.4×20.9×39.8 / 39.8×26.6×48.4875×530×1010 / 1010×675×1230
37.8×20.9×46.4 /42.9× 26.6×59.4960×530×1180 / 1090×675×1510
31.5×29.5×66.9 / 36.8×34.8×75800×750×1700 / 935×885×1905
3 Phase 3 wire / 3 Phase 4 wire and ground
Return to 90% with 4 cycle
Bypass after 30 min while overload >100% <125%Bypass after 30 sec while overload =125% <150%
Bypass after 30 cycles while overload exceed ≥ 150%
0°~40°C / 32°~104°F-25~55°C / -13~130°F
3,500 meters max. elevation, 0-95% humidity non-condensing
UPS output cut off immediately
PHYSICAL
208V /120V
Specifications
34.4×20.9×39.8 / 39.8× 26.6×48.4875×530×1010 / 1010×675×1230
37.8×20.9×46.4 / 42.9×26.6×59.4960×530×1180 /1090× 675×1510
31.5×29.5×66.9 / 36.8× 34.8×75800×750×1700 / 935×885×1905
31.5×43.3×70.9 / 36.2×48.0×79.1800×1100×1800 / 920×1220×2010
1019.8 / 1103.5463 / 501
1874.4 / 2094.7851 / 951
Specifications are subject to change without notices.
Sine Wave
Line InteractiveUPS Series
On-Line UPSSeries
Stabilizer Series
NetworkingSeries
Inverter Series Surge Series Power Storage Series
Standby UPSSeries
43.
DS10KC33/ DS15KC33/ DS22.5KC33/ DS30KC33/ DS45KC33/ DS60KC33/DS80KC33/ DS100KC33/ DS120KC33
Durable Series For data centers and missioncritical systems
Specifications
I-USE F-USECabinet Type
Battery
DC Voltage
Cabinet Dimension (LxWxH)
Empty Cabinet (Net/ Gross Weight)
With Battery (Net/ Gross Weight)
7.2AH x 30 pcs x 2 Teams, total 60 pcs
1234W x 30 pcs x 2 Teams, total 60 pcs
12V/17AH x 30 pcs x 1 Team, total 30 pcs
12V/17AH x 30 pcs x 2 Teams, total 60 pcs
360 VDC
600 x 344 x 660 683 x 400 x 1010
50 / 68 kg 51 / 84 kg
203 / 221kg
208 / 226 kg
226 / 310 kg
449 / 493 kg
E-USE G-USECabinet Type
Battery
DC Voltage
Cabinet Dimension (LxWxH)
Empty Cabinet (Net/ Gross Weight)
With Battery (Net/ Gross Weight)
26AH x 30 pcs x 1 Team, total 30 pcs
40AH x 30 pcs x 2 Teams, total 60 pcs
65AH x 30 pcs x 1 Team, total 30 pcs
100AH x 30 pcs x 1 Team, total 30 pcs
340 / 384 kg 1272 / 1307 kg
1056 / 1091 kg
1458 / 1493 kg
360 VDC
649 x 398 x 1010 1290 x 800 x 1700
65 / 109 kg 402 / 437 kg
E-USE/ F-USE
E-USE
F-USE
I-USE
BATTERYPACK
400.00 639.00
902.
00
REAR VIEW SIDE VIEW FRONT VIEW
Main Power Switch
Termainal Block
BATTERYPACK
400.00 682.00
902.
00
REAR VIEW SIDE VIEW FRONT VIEW
2
1
21
Main Power Switch
Termainal Block
12
Line InteractiveUPS Series
On-Line UPSSeries
Stabilizer Series
NetworkingSeries
Inverter Series Surge Series Power Storage Series
Standby UPSSeries