TRANSCRIPT

  • 8/13/2019 4692_iron__

    1/7

    Service Documentation Market Release 4/98

    Braun OptiGlide - Jet PV 2250 4692

    4692

  • 8/13/2019 4692_iron__

    2/7 4692 - 2

    BINC Rev:3/98 Service Documentation

    Exploded Drawing

    BAG Rev: 2/98 4692

  • 8/13/2019 4692_iron__

    3/7 4692 - 3

    BINC Rev: 9/99 Service Documentation

    Spare Parts List

    BAG Rev: 2/98 4692

    Pos. No. Part Description Part Number

    1 Sole plate not for exchange

    2 Spacer tube 4316656

    3 Seal 4316626

    4 Valve nozzle 4316627

    5 Lower housing 4693623

    6 Screw 4316631

    7 Tube 4316628

    8 Screw 4316632

    10 Reflector 4316630

    11 Thermostat lever 4316633

    12 Slider 4316641

    13 Container cpl. 4692634

    - Seal for container 4316647

    14 Screw 4318625

    15 Jet pump cpl. 4316636

    16 Spray/supershot pump cpl. 4314622

    17 Temperature control knob 4691631

    18 Upper housing 4692635

    20 Screw 4318626

    21 Pilot-light window 4693626

    22 Steam regulating knob 431863023 Mains lead with PCB NLA

    24 Cable clamp 4318627

    25 Screw 4318629

    26 Cover plate 4692636

    27 Screw 4318628

    28 PCB see position 23

    29 Cable clip 4316651

    30 Swivel bearing 4316653

    31 Measuring beaker 4316649

  • 8/13/2019 4692_iron__

    4/7 4692 - 4

    BINC Rev:3/98 Service Documentation

    Service Information

    BAG Rev: 2/98 4692

    Technical data:

    Nominal voltage: 120 V

    Nominal frequency: 50 - 60 Hz

    Nominal power: 1200 W

    Sole plate temperature: Maximum: 230 - 240 C < 110 C < 150 C < 200 C

    Flow quantities: Normal: 12-16 g/min

    Only works in horizontal position.

    Jet: 0.1-0.4 g/operation

    Super shot: 0.1-0.8 g/operation

    Spray: 0.1-0.8 g/operation

    Extra steam: 1 - 2.2 g/operation

    Only works in horizontal position

    Automatic shut-off: Mercury free. Yellow pilot light will flash when automatic shut-off isactivated within approx.30 seconds if the iron is standing in

    horizontal position without being moved. 15 minutes if the iron is

    standing in vertical position without being moved.

    Capacity, container: approx. 215 ml

    Sole plate: Die-cast metal, ceramic-coated (71 steam vents)

    Temperature display: Glow lamp

    Length of mains lead: approx. 1.95 Meters

    Accessory: Measuring beaker

    Important: The fuse and the thermostat may not be altered. The contacts may

    neither be bent, re-bent or re-soldered nor may they be bridged in any

    way.

    Special screws: The special screws used in the device can only be untightened by means of a

    special screwdriver blade. For reasons of approbation and security, only

    these special screws are to be used.

  • 8/13/2019 4692_iron__

    5/7 4692 - 5

    BINC Rev:3/98 Service Documentation

    Service Information

    BAG Rev: 2/98 4692

    Disassembly:

    Unscrew the screws (25) and remove the cover plate (26) to the backside.

    Unscrew the screws (27) and remove the swivel bearing (30) from the upper housing (18).

    Pull the glow lamp (28) out of the handle by the connecting leads. Disconnect all electrical plug-inconnections. The mains lead (23) is provided with self-securing plug-in connectors; the securingpins must be pressed slightly backwards during the disassembling process.

    Due to UL regulations, the glow lamp (28) and the mains lead (23) cannot be separated fromeach other and must be replaced as one part only.

    Turn the steam regulation knob (22) clockwise until the double arrow mark is reached; then removestraight upwards.

    Unscrew the screws (14) and the screw (20) and remove the upper housing (18).

    Slide the slider (12) out of the lead in a downward movement.

    Press the water spray nozzle out of the lead in an upward movement.

    Remove the hoses of the pumps cpl. (15,16) from the tubes.

    Remove the pumps cpl. (15,16) by inserting a small screwdriver close to the leading pins.

    Pry the temperature control knob (17) upwards and remove the thermostat lever (11).

    Unscrew the screw (14) and remove tank cpl. (13).

    Snap out the reflector (10) by means of a screwdriver.

    Unscrew the screws (8,6) and separate the lower housing (5) from the contact position by slightlylifting the front part; then remove the lower housing upwards.

    Valve nozzle (4), seal (3) and both tubes (7) are contained in the lower housing (5) and can, now,

    be easily removed.

    Thermostat fuse and thermostat are fixed at the sole plate cpl. (1); these parts may not berepaired.

    Assembly:

    In general, the re-assembly is made in reverse order. However, the following points must be taken

    in consideration:

  • 8/13/2019 4692_iron__

    6/7 4692 - 6

    BINC Rev:3/98 Service Documentation

    Service Information

    BAG Rev: 2/98 4692

    Before reassembling the lower housing (5), the valve nozzle (4), seal (3) and tubes (7) must be

    assembled orderly.

    Absolute care must be taken that the tank cpl. (13), the pumps cpl. (15, 16), the tube connections

    and all seals are watertight.

    Temperature Check:After each repair, the temperature must be checked at the center of the sole

    plate (marked X in the drawing) (see sketch 1).

    Measuring procedure:

    1 . The device may not show any defect.

    2. The steam regulating knob must be positioned at "0".

    3. Fasten the measuring sensor at the center of the iron by positioning the

    slider of the temperature measuring device at 3

    4. Operate the iron in the "Maximum" mode (max.).

    5. Wait until the control display extinguishes for the first time.

    6. Leave the iron in this mode for another approx. 3-5 minutes so that the

    temperature can stabilize.

    7. Observe the temperature for a period of at least one on/off-cycle of the

    thermostat (see control display). During this period, the temperature must

    not exceed 230 C and not be considerably lower than 180 C.

    In case that the measuring device indicates a considerable variation, the sole

    plate must be exchanged, because an adjustment of the thermostat is not

    possible.

    Special tools: Torx Bit T-20 for screw (25): Item no.: 4000138