5 port pilot operated solenoid valve …stevenengineering.com/tech_support/pdfs/70d4svfs.pdf1.8 1.8...
TRANSCRIPT
Series Type of actuation
Voltage Electrical entry With light/surgevoltage suppressor
(Option)
Manualoverride
VFS1000(P.1114)
VFS2000(P.1122)
VFS3000(P.1130)
Grommet Grommet terminal (E)
Conduit terminal (T)
DIN terminal (D)
VFS2000Plug-in type
Non plug-in type(P.1138)
VFS3000Plug-in type
Non plug-in type(P.1162)
VFS4000Plug-in type
Non plug-in type(P.1182)
VFS5000Plug-in type
Non plug-in type(P.1202)
VFS6000Plug-in type
Non plug-in type(P.1218)
3position
SingleDouble
1.8 1.8
3.4 3.4
6.8 6.5
2.8 2.7
5.8 5.4
12 11
20 17
38 —
2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center
2 position single
2 position double
2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center
3 position double check
Sonic conductanceC [dm3/s·bar)]
4/2 5/3(A/B R1/R2)
Bo
dy
Po
rted
Series Variations
VFS1000/2000/3000/4000/5000/6000 Series
5 Port Pilot Operated Solenoid Valve
Metal Seal
(Standard)
100 VAC, 50/60 Hz200 VAC, 50/60 Hz24 VDC
(Option)
110 to 120 VAC, 50/60 Hz220 VAC, 50/60 Hz240 VAC, 50/60 Hz 12 VDC100 VDC
(G) �With light/surge voltage suppressor
• Grommet terminal (EZ)• Conduit terminal (TZ)• DIN terminal (DZ)
�With surge voltage suppressor
• Grommet (GS)Note) • Indicator light is not
available for grommet type. Only surge voltage suppressor can be equipped on the middle of lead wire.
• DC: There is polarity.(Lead wireRed: +, Black: –)
Non-lockingpush type(Flush)
Non-lockingpush type(Extended)
Locking type(Tool required)
Locking type ∗(Lever)
∗ Locking type (lever) is not available for body ported Series VFS2000/3000.
Non-lockingpush type(Flush)
Non-lockingpush type(Flush)
Non-lockingpush type(Extended)
Locking type(Tool required)
Locking type(Lever)
(Standard)
100 VAC, 50/60 Hz200 VAC, 50/60 Hz24 VDC
(Option)
110 to 120 VAC, 50/60 Hz220 VAC, 50/60 Hz240 VAC, 50/60 Hz 12 VDC100 VDC
Conduitterminal (F)
Grommetterminal (E)Grommet (G)
Plug-in
Non plug-in
Conduitterminal (T)
DIN terminal(D)
DINterminal (D)
Grommetterminal (E)
Non plug-in
Conduitterminal (F)
Plug-in
DIN terminal (D)
Conduitterminal (F)
Grommetterminal (E)
Plug-in
Non plug-in
�With light/surge voltagesuppressor• Plug-in typeConduit terminal (FZ)
• Non plug-in typeGrommet terminal (EZ)Conduit terminal (TZ)DIN terminal (DZ)
Note) • Indicator light is not available for grommet type. Only surge voltage suppressor can be equipped on the middle of lead wire.
• DC: There is polarity.(Lead wireRed: +, Black: –)
�With surge voltage suppressor• Non plug-in typeGrommet (GS)
�With light/surge voltagesuppressor
• Plug-in typeConduit terminal (FZ)
• Non plug-in typeGrommet terminal (EZ)DIN terminal (DZ)
Bas
e M
ou
nte
d
1111
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:52 PM Page 1111
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Manifold
(P.1119)
(P.1127)
(P.1136)
(P.1146) (P.1146) (P.1146) (P.1146)
(P.1168) (P.1168) (P.1168)
(P.1188) (P.1188) (P.1188)
(P.1208) (P.1208) (P.1208)
(P.1146)
(P.1168)
(P.1188)
(P.1208)
VFS1000
VFS2000
VFS3000
VFS2000
VFS3000
VFS4000
VFS5000
VFS2000
VFS3000
VFS4000
VFS5000
Manifold Variations
Barbase
Stackingbase
∗ Bottom piping is available as an option.
Withattachment
plug lead wire
Withterminal
block
Withmulti-
connector
WithD-sub
connector
Non plug-in(Connection to
each valve)
Body
Por
ted
Bar Base(Series VFS1000/2000)
Plug-in
Non Plug-in
Stacking base(Series VFS3000)
Pilot individual EXH
Pilot common EXH
Pilot common EXH
With attachment plug lead wire
With multi-connector
With terminal block
With D-sub connector
Grommet terminal DIN terminal
Base
Mou
nted
Plu
g-i
n T
ype
Base
Mou
nted
No
n P
lug
-in
Typ
e
1112
Series VFS
P1111-P1228-E.qxd 08.9.2 2:52 PM Page 1112
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Manifold Option Manifold Option PartsWith
exhaustcleaner
�(P.1158)
�(P.1136)
�(P.1127)
�(P.1119)
Note)�(P.1155)
Note)
Note)
Note)
Note)
�(P.1178)
�(P.1198)
�(P.1153)
�(P.1175)
�(P.1195)
�(P.1173)
�(P.1193)
�(P.1212)
�(P.1153)
�(P.1175)
�(P.1195)
�(P.1173)
�(P.1193)
�(P.1212)
�(P.1214)
�(P.1148)
�(P.1170)
�(P.1190)
�(P.1209)
�(P.1148)
�(P.1170)
�(P.1190)
�(P.1209)
�(P.1148)
�(P.1170)
�(P.1190)
�(P.1209)
�(P.1148)
�(P.1170)
�(P.1190)
�(P.1209)
�(P.1148)
�(P.1170)
�(P.1190)
�(P.1209)
�(P.1148)
�(P.1170)
�(P.1190)
�(P.1209)
�(P.1148)
�(P.1170)
�(P.1190)
�(P.1209)
�(P.1148)
�(P.1148)
�(P.1148)
�(P.1170)
�(P.1190)
�(P.1209)
�(P.1148)
�(P.1170)
�(P.1190)
�(P.1209)
�(P.1148)
�(P.1170)
�(P.1190)
�(P.1209)
�(P.1148)
�(P.1170)
�(P.1190)
�(P.1209)
�(P.1148)
�(P.1170)
�(P.1190)
�(P.1209)
�(P.1148)
�(P.1170)
�(P.1190)
�(P.1209)
�(P.1148)
�(P.1170)
�(P.1190)
�(P.1209)
�(P.1148)
�(P.1148)
�(P.1148)
�(P.1170)
�(P.1190)
�(P.1209)
�(P.1148)
�(P.1170)
�(P.1190)
�(P.1209)
Serialtransmissionkit manifold
(EX123/4-typecompatible)
IndividualSUP
spacer
IndividualEXH
spacer
SUPblockdisk
EXHblockdisk
Throttlevalve
spacer
Interfaceregulator
Air shutoffvalve
spacer
Air releasevalve
spacer
Doublecheckspacer
Blankingplate
Withcontrol
unit
Dripproofmanifold
(Equivalentto IP65)
With exhaust cleaner
With control unit
Individual SUP spacer Interface regulator
Individual EXH spacer
Air shutoff valve spacer
SUP/EXH block disk
Throttle valve spacer
Air release valve spacer
Double check spacer
Note) Made to Order Specifications
Dripproof Manifold (Equivalent to IP65)With serial transmission kit
1113
Series VFSMetal Seal5 Port Pilot Operated Solenoid Valve
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:52 PM Page 1113
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
ModelType of actuation
VFS1120
VFS1220
VFS1320
VFS1420
VFS1520
VFS1130 1.7
1.7
1.6
1.7
1.7
0.22
0.22
0.20
0.18
0.24
0.38
0.39
0.37
0.38
0.40
0.19
0.19
0.20
0.19
0.18
0.40
0.40
0.41
0.44
0.37
1.8
1.8
1.8
1.9
1.6
VFS1230
VFS1330
VFS1430
VFS1530
Portsize
1200
1200
600
600
600
0.18
0.26
0.27
0.27
0.27
Note 1) Based on JIS B 8375 (once per 30 days) for the minimum operating frequency.Note 2) According to JIS B 8375-1981. (The value at supply pressure 0.5 MPa.)Note 3) In the case of grommet typeNote 4) “Note 1)” and “Note 2)” are with controlled clean air.
C[dm3/(s·bar)] b Cv
C[dm3/(s·bar)] b Cv
1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)Flow characteristics
1 8
1 8
1 8
1 8
1 8
Model
Standard Specifications
Option Specifications
JIS Symbol
Manifold
Pilot valve manual override
Coil rated voltage
Foot bracket (With screw)
110 to 120, 220, 240 VAC (50/60 Hz)Non-locking push type (Extended), Locking type (Tool required), Locking type (Lever)
12, 100 VDCOption With light/surge voltage suppressor Note)
Part No.: AXT626-10A, VFS1120 (single) only
Body type
VFS1�30VFS1�20
Bar manifold (Common EXH base side)Bar manifold (Individual EXH)
Applicable manifold base (Pilot EXH)
2 position 3 positionSingle Closed center
Double Exhaust center
Pressure center
VFS1320-�D-01
VFS1120-�G-01-F
VFS1120-�G-01
VFS1220-�E-01
Compact yet provides a large flow capacityC: 1.8 dm3/(s·bar)Low power consumption: 1.8 W DC
2 po
sitio
n3
posi
tion
Single
Double
Closedcenter
Pressure center
Exhaust center
Max. operating
cycle(cpm)
Responsetime(ms)
Mass(kg)
15 or less
13 or less
20 or less
20 or less
20 or less
FluidMaximum operating pressure
InrushHolding
2 position3 position
Min. operating pressure
Ambient and fluid temperatureProof pressure
LubricationPilot valve manual overrideShock/Vibration resistance EnclosureCoil rated voltageAllowable voltage fluctuationCoil insulation typeApparent power(Power consumption)
Electrical entry
Air/Inert gas1.0 MPa0.1 MPa0.15 MPa
–10 to 60°C (1)
Non-lube (2) Non-locking push type (Flush)
150/50 m/s2 (3)
Dustproof (Degrees of protection 0) (4)
100, 200 VAC, 50/60 Hz; 24 VDC–15 to +10% of rated voltage
5.6 VA (50 Hz), 5.0 VA (60 Hz)3.4 VA (2.1 W)/50 Hz, 2.3 VA (1.5 W)/60 Hz
Grommet, Grommet terminal,Conduit terminal, DIN terminal
1.5 MPa
Class B or equivalent (130°C) (5)
1.8 W (2.04 W: With light/surge voltage suppressor)Power consumption (DC)
Note 1) Use dry air at low temperatures.Note 2) Use turbine oil Class 1 (ISO VG32), if lubricated.Note 3) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial
direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period)
Note 4) Based on JIS C 0920. Note 5) Based on JIS C 4003.
Val
ve s
pec
ific
atio
ns
Elec
tric
ity s
peci
ficat
ions
AC
Note) Grommet type is available only w/ surge voltage suppressor (which is directly connected with lead wire).
Note) VFS1�30: Manifold only. Cannot be used as a single unit.
(1)(2)
(3)
1114
5 Port Pilot Operated Solenoid ValveMetal Seal, Body Ported
Series VFS1000
VFS.qxd 10.11.25 9:49 AM Page 1
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
01VFS1 1 20Symbol
1
2
3
4
5
Electrical entryBody (Pilot exhaust)
Manual override
Light/Surge voltage suppressor
Option
1 G
Coil rated voltage
Coil rated voltage Manual override21
22
Applicable modelSF4 DZ1 21
Electrical entry, Light/Surge voltage suppressor
How to Order Pilot Valve Assembly
2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center
T: Conduit terminal D, Y: DIN terminal
F: With foot bracket
G: Grommet E: Grommet terminal20: Individual EXH
30∗: Common EXH
Nil: Non-locking push type(Flush)
B∗: Locking type
∗ Option
∗ Grommet type is available only w/ surge voltage suppressor, not w/ indicator light.
Nil Z
NoneWith light/surge voltage suppressor
S∗ With surge voltage suppressor
01 Rc 1 8
Port sizeNilN∗
RcNPT
NPTFG
T∗
F∗
∗ Option
Thread type
∗ Option∗ Manifold only
∗ Mountable only for VFS1120.
3∗21
4∗
6∗5
7∗
100 VAC (50/60 Hz)200 VAC (50/60 Hz)
110 to 120 VAC (50/60 Hz)220 VAC (50/60 Hz)
24 VDC12 VDC
240 VAC (50/60 Hz)9∗ Other
1 100 VAC, 50/60 Hz2 200 VAC, 50/60 Hz3∗ 110 to 120 VAC (50/60 Hz)4∗ 220 VAC, 50/60 Hz5 24 VDC6∗ 12 VDC7∗ 240 VAC, 50/60 Hz9∗ Other
∗ Option ∗ Option
Nil
B∗
A∗
C∗
Non-locking pushtype (Flush)
Non-locking pushtype (Extended)
Locking type(Tool required)Locking type
(Lever)
Individual pilot exhaust
Common pilot exhaust
For VFS1�20
For VFS1�30GGS
GrommetGrommet with surge voltage suppressor
DIN terminalDIN terminal with light/surge voltage suppressor
DDZ
DIN terminal ∗∗DIN terminal with light/surge voltage suppressor ∗∗
DIN terminalDIN terminal with light/surge voltage suppressor
DIN terminal ∗∗DIN terminal with light/surge voltage suppressor ∗∗
DODOZY∗YZ∗YO∗YOZ∗
Conduit terminalConduit terminal with light/surge voltage suppressor
TTZ
Grommet terminalGrommet terminal with light/surge voltage suppressor
EEZ
A∗: Non-locking push type(Extended)
C∗: Locking type (Lever)
How to Order
∗ Y: Conforming to DIN43650B standard∗∗ DIN connector is not attached.
Q
CE-compliantNil —
CE-compliant
1115
Series VFS10005 Port Pilot Operated Solenoid ValveMetal Seal, Body Ported
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
1-2-16-VFS1000.qxd 10.3.29 5:46 PM Page 1
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
VFS1120-01
800700600500400300200100 0
ø6 ø10 ø16 ø20 ø25 ø32 ø40 ø40 ø50 ø63 ø80 ø100
Body Ported
Construction
Body ported Series CJ2 Series CM2 Series MB, CA2
VFS1120-01
Conditions
23
1
4
———
56 —7 —
———
Component Parts
Cylinder Speed Chart
2 position single 2 position double
3 position closed center/exhaust center/pressure centerClosed center
Exhaust center
Pressure center
Stainless steelReturn springPilot valve assembly Detent assembly
∗ Refer to “How to Order Pilot Valve Assembly” on page 1115.
No. Description
Stainless steelResin
MaterialAluminum die-casted
Note
Spool/SleeveBody
End plateResinPiston
Platinum silver
SeriesAveragespeed(mm/s)
Bore sizeSeries CJ2Pressure 0.5 MPaLoad factor 50%Stroke 60 mm
Series CM2Pressure 0.5 MPaLoad factor 50%Stroke 300 mm
Series MB, CA2Pressure 0.5 MPaLoad factor 50%Stroke 500 mm
Perpendicular,upward actuationHorizontalactuation
Use as a guide for selection.Please confirm the actual conditions with SMC Sizing Program.
AN101-01
T0604 x 1 mAS3001F-06
T0806 x 1 mAS3001F-08
Tube bore x LengthSpeed controllerSilencer
∗ It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open.
∗ The average velocity of the cylinder is the value that the stroke is divided by the total stroke time.
∗ Load factor: ((Load weight x 9.8)/Theoretical force) x 100%
1116
Series VFS1000
P1111-P1228-E.qxd 08.9.2 2:52 PM Page 1116
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Grommet terminal: VFS1120-�E/EZ
Conduit terminal: VFS1120-�T/TZ
DIN terminal: VFS1120-�D/DZ/Y/YZ
( ): Y, YZ
Foot bracket (F)Part no. : AXT626-10A
2 Position Single — Grommet, Grommet terminal, Conduit terminal, DIN terminal
Grommet : VFS1120-�G
Manual overrideNon-locking push type
2 x ø4.5mounting hole
Solenoid valve
2 x ø3.5 mounting hole
≅ 30
0(L
ead
wire
leng
th)
5 x Rc 1/8
Lead wire O.D.Max. ø3.5 Applicable heavy-duty code
O.D. ø6 to ø8(Y: ø4.7 to ø7)
(Locking type)
Pilot EXH(No VFS1�30)
Manualoverride
2 x ø4.5 mounting hole
M3 x 0.5 x 14LCountersunk head screw
Tightening torque: 0.6 N·m
With light/surge voltage suppressor (EZ)
Light
Manual override(Locking type)
With light/surge voltage suppressor (DZ)
Light
Manual override(Locking type)
Applicable heavy-duty codeO.D. ø6 to ø8
With light/surge voltage suppressor (TZ)
Light
Manual override(Locking type)
1117
Series VFS10005 Port Pilot Operated Solenoid ValveMetal Seal, Body Ported
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:52 PM Page 1117
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
( ): Y, YZ
2 Position Double, 3 Position — Grommet, Grommet terminal, Conduit terminal, DIN terminal
Grommet: VFS1220-�G, VFS1320-�G, VFS1420-�G, VFS1520-�G
DIN terminal : VFS1220-�D/DZ/Y/YZVFS1320-�D/DZ/Y/YZVFS1420-�D/DZ/Y/YZVFS1520-�D/DZ/Y/YZ
Grommet terminal: VFS1220-�E/EZ VFS1320-�E/EZVFS1420-�E/EZVFS1520-�E/EZ
Conduit terminal: VFS1220-�T/TZ VFS1320-�T/TZVFS1420-�T/TZVFS1520-�T/TZ
2 x ø4.5 mounting hole
151 (3 position: 155.5)
2 x ø3.5 mounting hole
≅300
(Lea
d w
ire le
ngth
)
Pilot EXH(No VFS1�30)
Lead wire O.D. Max. ø3.5 152 (3 position: 156.5)
Applicable heavy-duty cord O.D. ø6 to ø8 (Y: ø4.7 to ø7)
188 (3 position: 192.5)
188 (3 position: 192.5)
With light/surge voltage suppressor (DZ)
With light/surge voltage suppressor (TZ)
With light/surge voltage suppressor (EZ)
Light
Light
Light
Manual override(Locking type)
Manual override(Locking type)
(Locking type)
Manual override(Locking type)
Applicable heavy-duty cord O.D. ø6 to ø8
Manualoverride
Manual overrideNon-locking push type
1118
Series VFS1000
P1111-P1228-E.qxd 08.9.2 2:52 PM Page 1118
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Manifold base typeMax. 15 stations
Bar manifold, Body ported
PassageSymbol Valve
4(A), 2(B)Base
5(R1), 3(R2)Base1(P)
Side/Rc 1/85(R1), 3(R2)
Common1(P)
Common1
Porting specifications: Rc (Connecting port size)
Top/Rc 1/8 Side/Rc 1/8
Blanking plate VVFS1000-10A-1 With gasket, screw
10520 01Series VFS1000
Manifold
Symbol
Symbol
1
Passage Porting specifications2(B), 4(A)3(R2), 5(R1)1(P)
CommonRc
Stations
Base model
VV5FS1
Model Applicable valve model
20
30
Pilot exhaustPilot individual EXH
VFS1�20-��-01
Pilot common EXH
2 stations
15 stations
02
15
01
1 8
CommonRc 1 8
TopRc 1 8
VFS1�30-��-01
∗VFS1�20-��-01mountable
RcNPTNPTF
G
∗ Option
Thread type
P, EA, EB port size
Specifications
Port Specifications
Option
How to Order Manifold Base
VV5FS1-20
VV5FS1-30
Part no. for mounting bolt and gasket
BG-VFS1030
How to Order Manifold Assembly [Example]
<Example>(Manifold base)(2 position single)(2 position double)(Blanking plate)
Add the valve and option part numbers in order starting from the first station on the D side.
Compact and lightweightCompact due to manifolding on a single base for mounting in small spaces.
Keeps environmental air clean from pilot exhaustUse of the VV5FS1-30 manifold can exhaust intensively the pilot exhaust gas to the base side, and can prevent environmental aggravation due to noise and oil mist.
Stations
••
•
••
1321
VV5FS1-20-061-01VFS1120-1D-01VFS1220-1D-01VVFS1000-10A-1
NilN∗T∗F∗
Q
CE-compliantNil —
CE-compliant
Rc 1/8
∗ ∗ ∗
The asterisk denotes the symbol for assembly. Prefix it to the part numbers of the solenoid valve.
•
1119
Series VFS1000Manifold Specifications Single Base Type
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
1-02-16-VFS1000.qxd 09.11.2 1:31 PM Page 3
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Grommet terminal: E/EZ Conduit terminal: T/TZ DIN terminal: D/DZ/Y/YZ
( ): Y, YZ
Formula for manifold weight M = 0.049n + 0.059 (kg) n: Station
n: Station
Grommet: G
Type 20 Manifold — Pilot individual exhaust: VV5FS1-20- 1-01
4 x ø5.2 mounting hole
GasketPilot EXH
Stations
Lead wire O.D.Max. ø3.5
(With light/surge voltage suppressor: 82.5)
(With light/surge voltage suppressor: 91.5)(With light/surge voltage suppressor: 86.5)
(With light/surge voltage suppressor: 96.5)
(With light/surge voltage suppressor: 97.5 (99.5))
(With light/surge voltage suppressor: 106.5 (108.5))
Applicable heavy-duty cordO.D. ø6 to ø8
Applicable heavy-duty cordO.D. ø6 to ø8(Y: ø4.7 to ø7)
3 po
sitio
n (1
56.5
)D
oubl
e (1
52)
Sin
gle
(103
.5)
3 po
sitio
n (1
92.5
)D
oubl
e (1
88)
Sin
gle
(121
.5)
3 po
sitio
n (1
92.5
)D
oubl
e (1
88)
Sin
gle
(121
.5)
3 position Double Single
Blanking plate
Manual override
≅300(Lead wire length)
U side D side
25977
SymbolL1
L2
383
101
4107125
5131149
6155173
7179197
8203221
9227245
10251269
FormulaL1 = 24 x n + 11L2 = 24 x n + 29
Stations
Station
1120
Series VFS1000
P1111-P1228-E.qxd 08.9.2 2:52 PM Page 1120
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Grommet terminal: E/EZ Conduit terminal: T/TZ DIN terminal: D/DZ/Y/YZ
( ): Y, YZ
Formula for manifold weight M = 0.079n + 0.093 (kg) n: Station
Grommet: G
25977
SymbolL1
L2
383
101
4107125
5131149
6155173
7179197
8203221
9227245
10251269
FormulaL1 = 24 x n + 11L2 = 24 x n + 29
Stationsn: Station
4 x ø5.2 mounting hole
Gasket
Lead wire O.D.
Stations
3 position Double Single
Pilot EXH port
Pilot EXH port
Blanking plate
Manual override
≅300(Lead wire length)
U side D side
3 po
sitio
n (1
56.5
)D
oubl
e (1
52)
Sin
gle
(103
.5)
(With light/surge voltage suppressor: 87.5)
(With light/surge voltage suppressor: 96.5)
Applicable heavy-duty codeO.D. ø6 to ø8
Pilot EXH port
3 po
sitio
n (1
92.5
)D
oubl
e (1
88)
Sin
gle
(121
.5)
(With light/surge voltage suppressor: 91.5)
(With light/surge voltage suppressor: 101.5)
Applicable heavy-duty codeO.D. ø6 to ø8(Y: ø4.7 to ø7)
Pilot EXH port
3 po
sitio
n (1
91.5
)D
oubl
e (1
87)
Sin
gle
(121
)
(With light/surge voltage suppressor: 102.5 (104.5))
(With light/surge voltage suppressor: 111.5 (113.5))
4 x M5
Type 30 Manifold — Pilot common exhaust: VV5FS1-30- 1-01Station
1121
Series VFS10005 Port Pilot Operated Solenoid ValveMetal Seal, Body Ported
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:52 PM Page 1121
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
1 8
1 8
1 4
1 41 81 41 81 41 81 4
ModelType of actuation
PortsizeRc
1200
1200
600
600
600
22 or less
13 or less
40 or less
40 or less
40 or less
1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) Flow characteristics
VFS2320
VFS2420
VFS2520
VFS2120
VFS2220
3.24.03.24.03.24.03.24.03.14.0
0.240.200.240.200.240.200.250.200.230.24
0.780.900.780.900.780.900.790.900.750.92
3.43.53.43.53.23.43.43.43.33.3
0.280.320.280.320.270.290.260.320.270.30
0.820.850.820.850.800.830.820.840.800.82
VFS2330
VFS2430
VFS2130
VFS2230
VFS2530
0.42
0.42
0.26
0.35
0.42
Model
Standard Specifications
Option Specifications
Manifold
JIS Symbol
VFS2320-�T-02
VFS2220-�E-02
VFS2120-�E-02-F
VFS2120-�G-02
2 position 3 positionSingle Closed center
Double Exhaust center
Pressure center
Pilot valve manual override
Coil rated voltage
Foot bracket (With screw)
Pilot type
Option
Note 1) Based on JIS B 8375 (once per 30 days) for the minimum operating frequency.Note 2) According to JIS B 8375-1981. (The value at supply pressure 0.5 MPa.)Note 3) In the case of grommet type Note 4) Factors of “Note 1)” and “Note 2)” are achieved in controlled clean air.
Single
Double
Closedcenter
Pressure center
Exhaust center
C[dm3/(s·bar)] b Cv
C[dm3/(s·bar)] b Cv
Fluid Air/Inert gasMaximum operating pressureMinimum operating pressure
1.0 MPa0.1 MPa
–10 to 60°C (1)
Non-lube (2)
Non-locking push type (Flush)150/50 m/s2 (3)
Dustproof (Degrees of protection 0) (4)
100, 200 VAC, 50/60 Hz; 24 VDC–15 to +10% of rated voltage
5.6 VA (50 Hz), 5.0 VA (60 Hz)3.4 VA (2.1 W)/50 Hz, 2.3 VA (1.5 W)/60 Hz
InrushHolding
Grommet, Grommet terminal,Conduit terminal, DIN terminal
Ambient and fluid temperature1.5 MPaProof pressure
LubricationPilot valve manual overrideShock/Vibration resistance EnclosureCoil rated voltageAllowable voltage fluctuation
Class B or equivalent (130°C) (5)Coil insulation typeApparent power(Power consumption)
Electrical entry
1.8 W (2.04 W: With light/surge voltage suppressor)Power consumption
Note 1) Use dry air at low temperatures.Note 2) Use turbine oil Class 1 (ISO VG32), if lubricated.Note 3) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial
direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period)
Note 4) Based on JIS C 0920. Note 5) Based on JIS C 4003.
Val
ve s
pec
ific
atio
ns
Elec
tric
ity s
peci
ficat
ions
AC
110 to 120, 220, 240 VAC (50/60 Hz)Non-locking push type (Extended), Locking type (Tool required)
External pilot (1)
12, 100 VDC
Note 1) Operating pressure: 0 to 1.0 MPa. Pilot pressure: 0.1 to 1.0 MPa.Note 2) Grommet type is available only w/ surge voltage suppressor (which is directly connected with
lead wire), not w/ indicator light.
With light/surge voltage suppressor (2)
Part no.: VFN200-17A, VFS2120 (single) only
Body type
VFS2�30Note) VFS2�30: Manifold only. Cannot be used as a single unit.
VFS2�20Bar manifold (Common EXH base side)
Bar manifold (Individual EXH)Applicable manifold base (Pilot EXH)
2 po
sitio
n3
posi
tion
Max. operating
cycle(cpm)
Responsetime(ms)
Mass(kg)
(1) (2) (3)
Compact yet provides a high flow capacity1/4: C: 3.4 dm3/(s·bar)Low power consumption: 1.8 W DC
5 Port Pilot Operated Solenoid ValveMetal Seal, Body Ported
Series VFS2000(Details → P. 1137-1)
1122
VFS.qxd 10.11.25 9:49 AM Page 2
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
VFS2Symbol
1: 2 position single
2: 2 position double
3: 3 position closed center
4: 3 position exhaust center
5: 3 position pressure center
Electrical entryT: Conduit terminal D, Y: DIN terminal
F: With foot bracket
G: Grommet E: Grommet terminal
Body (Pilot exhaust)20: Individual EXH
30: Common EXH∗
Manual override
Light/Surge voltage suppressor
RcNPT
NPTFG
0102
∗ Option
Thread type
Port size
Option
1 20 011 G
Coil rated voltage
Internal pilotNilExternal pilotR∗
Pilot type
Coil rated voltageApplicable model
SF4 DZ1 12
How to Order Pilot Valve Assembly
123∗4∗56∗7∗9∗
100 VAC, 50/60 Hz200 VAC, 50/60 Hz
110 to 120 VAC (50/60 Hz)220 VAC, 50/60 Hz
24 VDC12 VDC
240 VAC, 50/60 HzOther
∗ Option∗ Option
Nil
B∗A∗
Non-locking push type (Flush)
Individual pilot exhaust
Common pilot exhaust
Non-locking push type (Extended)Locking type (Tool required)
For VFS2�20
For VFS2�30
Manual override
12
13
Electrical entry, Light/Surge voltage suppressorGGSDDZ∗DO∗DOZ∗Y∗YZ∗YO∗YOZ∗
TTZ
GrommetGrommet with surge voltage suppressor
DIN terminalDIN terminal with light/surge voltage suppressor
DIN terminal ∗∗DIN terminal with light/surge voltage suppressor ∗∗
DIN terminalDIN terminal with light/surge voltage suppressor
DIN terminal ∗∗DIN terminal with light/surge voltage suppressor ∗∗
Conduit terminalConduit terminal with light/surge voltage suppressor
Grommet terminalGrommet terminal with light/surge voltage suppressor
EEZ
Nil: Non-locking push type(Flush)
A∗: Non-locking push type(Extended)
B∗: Locking type(Tool required)
∗ Option
∗ Grommet type is available only w/ surge voltage suppressor, not w/ indicator light.
NilZ
NoneWith light/surge voltage suppressor
S∗ With surge voltage suppressor
NilN∗T∗F∗
Rc 1 8
Rc 1 4
∗ Option
∗ Reverse pressure: Can be used by external pilot specifications.
∗ Manifold only
∗ Mountable only for VFS2120.
3∗21
4∗
6∗5
7∗
100 VAC (50/60 Hz)200 VAC (50/60 Hz)
110 to 120 VAC (50/60 Hz)220 VAC (50/60 Hz)
24 VDC12 VDC
240 VAC (50/60 Hz)9∗ Other
∗ Option: Individual external pilot (Ex-ternal pilot port: Body side)
∗ Y: Conforming to DIN43650B standard∗∗ DIN connector is not attached.
How to Order
1123
Series VFS20005 Port Pilot Operated Solenoid ValveMetal Seal, Body Ported
Q
CE-compliantNil —
CE-compliant
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
1-2-16-VFS1000.qxd 10.3.29 5:46 PM Page 2
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Cylinder Speed Chart
Construction
2 position single 2 position double
3 position closed center/exhaust center/pressure center
Series
VFS2120-02
800700600500400300200100 0
Bore size
ø6 ø10 ø16 ø20 ø25 ø32 ø40 ø40 ø50 ø63 ø80 ø100
Body Ported
Conditions
No.
23
1Description
Stainless steelResin
MaterialAluminum die-casted
Note
4 Resin
——
Platinum silver
—56
Stainless steel—
7 —
———
∗ Refer to “How to Order Pilot Valve Assembly” on page 1123.
Component Parts
Spool/SleeveBody
End platePistonReturn springPilot valve assembly Detent assembly
Closed center
Exhaust center
Pressure center
Averagespeed(mm/s)
Series CJ2Pressure 0.5 MPaLoad factor 50%Stroke 60 mm
Series CM2Pressure 0.5 MPaLoad factor 50%Stroke 300 mm
Series MB, CA2 Pressure 0.5 MPaLoad factor 50%Stroke 500 mm
Body ported Series CJ2 Series CM2
AN110-01
Series MB, CA2T0604 x 1 mAS3001F-06
T1075 x 1 mAS4001F-10
Tube bore x LengthSpeed controllerSilencer
VFS2120-02
∗ It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open.
∗ The average velocity of the cylinder is the value that the stroke is divided by the total stroke time.
∗ Load factor: ((Load weight x 9.8)/Theoretical force) x 100%
Use as a guide for selection.Please confirm the actual conditions with SMC Sizing Program.
Perpendicular,upward actuationHorizontalactuation
1124
Series VFS2000
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1124
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Grommet terminal: VFS2120-�E/EZ
Conduit terminal: VFS2120-�T/TZ
DIN terminal: VFS2120-�D/DZ/Y/YZ
( ): Y, YZ
Foot bracket (F)Part no.: VFN200-17A
2 Position Single — Grommet, Grommet terminal, Conduit terminal, DIN terminal
Grommet: VFS2120-�G
Manual override(Non-locking)
2 x ø3.5 mounting hole
2 x ø3.5 mounting hole
2 x ø3.5 mounting hole
2 x ø3.5 mounting hole
M5: External pilot port∗ Only for external pilot model.
≅300
(Lea
d w
ire le
ngth
)
2 x ø4.5 mounting hole Solenoid valve
With light/surge voltage suppressor (EZ)
Lead wire O.D.Max. ø3.5
Light
Light
With light/surge voltage suppressor (DZ)
With light/surge voltage suppressor (TZ)
Light
( )
Applicable heavy-duty code O.D. ø6 to ø8
Applicable heavy-duty code O.D. ø6 to ø8 (Y: ø4.7 to ø7)
3 x Rc 1/8, 1/4
2 x Rc 1/8
1125
Series VFS20005 Port Pilot Operated Solenoid ValveMetal Seal, Body Ported
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1125
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
( ): Y, YZ
2 Position Double, 3 Position — Grommet, Grommet terminal, Conduit terminal, DIN terminal
Grommet terminal:VFS2220-�E/EZ VFS2320-�E/EZVFS2420-�E/EZ VFS2520-�E/EZ
DIN terminal: VFS2220-�D/DZ/Y/YZVFS2320-�D/DZ/Y/YZVFS2420-�D/DZ/Y/YZVFS2520-�D/DZ/Y/YZ
Conduit terminal:VFS2220-�T/TZ VFS2320-�T/TZVFS2420-�T/TZ VFS2520-�T/TZ
Grommet: VFS2220-�G, VFS2320-�G, VFS2420-�G, VFS2520-�G
182 (3 position: 192.5)
Manual override(Non-locking)2 x ø3.5 mounting hole
2 x ø3.5 mounting hole
2 x ø3.5 mounting hole
2 x ø3.5 mounting hole
2 x ø3.5 mounting hole
≅300
(Lea
d wi
re le
ngth
)
(M5: External pilot port∗ Only for external pilot model.)
Light
With light/surge voltage suppressor (DZ)
219 (3 position: 229)Light
Light
3 x Rc 1/8, 1/4
Lead wire O.D. Max. ø3.5
With light/surge voltage suppressor (TZ)219 (3 position: 229)
With light/surge voltage suppressor (EZ)182 (3 position: 193)
2 x Rc 1/8
Applicable heavy-duty code O.D. ø6 to ø8
Applicable heavy-duty code O.D. ø6 to ø8 (Y: ø4.7 to ø7)
1126
Series VFS2000
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1126
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Specifications
Port Specifications
Option
How to Order Manifold Base
VV5FS2-20
VV5FS2-30
Blanking plate VVFS2000-10A-1 With gasket, screw
10520 03Series VFS2000
Manifold
Symbol
1
Passage Porting specifications2(B), 4(A)3(R2), 5(R1)1(P)
Stations
Base model
VV5FS2
Model Applicable valve model
20
30
Pilot exhaust
Pilot individual EXH
Pilot common EXH
2 stations
15 stations
02
15
RcNPT
NPTFG
∗ Option
Thread type
P, EA, EB port size
Part no. for mounting bolt and gasketBG-VFS2030
How to Order Manifold Assembly[Example]
03 3 8Rc
Keeps environmental air clean from pilot exhaustUse of the VV5FS2-30 manifold can exhaust intensively the pilot exhaust gas to the base side, and can prevent environmental aggravation due to noise and oil mist.
Manifold base typeStations Max. 15 stations
Bar manifold, Body ported
PassageSymbol Valve2(B), 4(A)
Base3(R2), 5(R1)
Base1(P)
Side: 5(R1), 3(R2)
Common1(P)
Common1
Porting specifications: Rc
3 8 Side: 3 8Top: 1 8, 1 4
Top
VFS2�20-��-
Rc 1 8, 1 4
VFS2�30-��-0102
∗VFS2�20-��-0102
mountable
NilN∗T∗F∗
0102
<Example>(Manifold base)(2 position single)(2 position double)(Blanking plate)
1321
VV5FS2-20-061-03VFS2120-1D-02VFS2220-1D-02VVFS2000-10A-1
•••
••
•
Add the valve and option part numbers in order starting from the first station on the D side.
Common3 8Rc
Common3 8Rc
Series VFS2000Manifold Specifications Single Base Type
∗∗∗
The asterisk denotes the symbol for assembly. Prefix it to the part num-bers of the solenoid valve.
Q
CE-compliantNil —
CE-compliant
1127
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
1-02-16-VFS1000.qxd 09.11.2 1:31 PM Page 5
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Grommet terminal: E/EZ Conduit terminal: T/TZ DIN terminal: D/DZ/Y/YZ
( ): Y, YZ
Formula for manifold weight M = 0.108n + 0.068 (kg) n: Station
25868
LL1
L2
38393
4108118
5133143
6158168
7183193
8208218
9233243
10258268
FormulaL1 = 25 x n + 8L2 = 25 x n + 18
Stationsn: Station
Type 20 Manifold — Pilot individual exhaust: VV5FS2-20- 1-03
Grommet: G
U side D side
2n x Rc 1/8, 1/4
M3 x 44
4 x ø5 mounting hole
Blanking plate
Pilot EXH
Gasket
Lead wire O.D.Max. ø3.5
Applicable heavy-duty codeO.D. ø6 to ø8
6 x Rc 3/8
Applicable heavy-duty codeO.D. ø6 to ø8 (Y: ø4.7 to ø7)
6 x Rc 3/8
3 po
sitio
n (1
93)
Dou
ble
(182
)
Sin
gle
(125
)
(With light/surge voltage suppressor: 91.5)
(With light/surge voltage suppressor: 101)
3 po
sitio
n (2
29)
Dou
ble
(219
)
Sin
gle
(143
)
(With light/surge voltage suppressor: 96)
(With light/surge voltage suppressor: 106)
3 po
sitio
n (2
29)
Dou
ble
(219
)
Sin
gle
(143
.5)
(With light/surge voltage suppressor: 108.5 (110.5))
(With light/surge voltage suppressor: 117.5 (119.5))
Stations
≅300(Lead wire length)
6 x Rc 3/8
6 x Rc 3/8
Station
1128
Series VFS2000
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1128
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Grommet terminal: E/EZ Conduit terminal: T/TZ DIN terminal: D/DZ/Y/YZ
( ): Y, YZ
Formula for manifold weight M = 0.12n + 0.21 (kg) n: Station
Grommet: G
Type 30 Manifold — Pilot common exhaust: VV5FS2-30- 1-03Station
26292
LL1
L2
387
117
4112142
5137167
6162192
7187217
8212242
9237267
10262292
FormulaL1 = 25 x n + 12L2 = 25 x n + 42
Stations
n: Station
U side D side
2n x Rc 1/8, 1/4
M3 x 44
4 x ø5 mounting hole
Blanking plate
Gasket
3 po
sitio
n (1
93)
Dou
ble
(182
)
Sin
gle
(125
)
3 po
sitio
n (2
29)
Dou
ble
(219
)
Sin
gle
(143
)
Stations
Lead wire O.D.Max. ø3.5
Applicable heavy-duty codeO.D. ø6 to ø8
(With light/surge voltage suppressor: 102.5)
(With light/surge voltage suppressor: 112.5)
3 po
sitio
n (2
29)
Dou
ble
(219
)
Sin
gle
(143
.5)
Applicable heavy-duty codeO.D. ø6 to ø8(Y: ø4.7 to ø7)
(With light/surge voltage suppressor: 115 (117))
(With light/surge voltage suppressor: 124 (126))
(With light/surge voltage suppressor: 98)
(With light/surge voltage suppressor: 107.5)
6 x Rc 3/8
4 x M5 (Pilot EXH port)
≅300(Lead wire length)
1129
Series VFS20005 Port Pilot Operated Solenoid ValveMetal Seal, Body Ported
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1129
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model
Standard Specifications
Option Specifications
Manifold
JIS Symbol
VFS3320-�E-03
VFS3220-�T-03
VFS3120-�E-03-F
VFS3120-�G-03
VFS3120
VFS3220
VFS3320
VFS3420
VFS3520
VFS31305.06.15.06.15.05.74.95.84.96.5
0.200.140.200.140.200.200.240.150.230.15
1.11.41.11.41.11.41.11.41.11.6
6.87.36.87.36.36.86.57.06.67.0
0.300.230.30.230.270.210.280.220.280.23
1.71.81.71.81.61.71.61.71.61.7
VFS3230
VFS3330
VFS3430
VFS3530
1 43 81 43 81 43 81 43 81 43 8
1200
1500
600
600
600
0.33
0.43
0.45
0.45
0.45
20 or less
15 or less
40 or less
40 or less
40 or less
C[dm3/(s·bar)] b Cv
C[dm3/(s·bar)] b Cv
1 4/2(P A/B) 4/2 5/3(A/B R1/R2)Flow characteristics
2 position 3 positionSingle Closed center
Double Exhaust center
Pressure center
Body type Applicable manifold base
Stacking manifoldVFS3�30VFS3�20
Common EXH (Manifold base side)Individual EXH (Valve side)
Pilot EXH
Compact yet provides a large flow capacity3/8: C: 6.8 dm3/(s·bar)Low power consumption: 1.8 W DC
Type of actuation
Single
Double
Closedcenter
Pressure center
Exhaust center
PortsizeRc
Note 1) Based on JIS B 8375 (once per 30 days) for the minimum operating frequency. Note 3) In the case of grommet type.Note 2) Based on JIS B 8375-1981. (The value at supply pressure 0.5 MPa.) Note 4) Factors of “Note1)” and “Note 2)” are achieved in controlled clean air.
Fluid Air/Inert gasMaximum operating pressureMinimun operating pressure
1.0 MPa0.1 MPa
–10 to 60°C (1)
Non-lube (2)
Non-locking push type (Flush)150/50 m/s2 (3)
100, 200 VAC, 50/60 Hz; 24 VDC–15 to +10% of rated voltage
5.6 VA/50 Hz, 5.0 VA/60 Hz3.4 VA (2.1 W)/50 Hz, 2.3 VA (1.5 W)/60 Hz
InrushHolding
Grommet, Grommet terminal,Conduit terminal, DIN terminal
Ambient and fluid temperature1.5 MPaProof pressure
LubricationPilot valve manual overrideShock/Vibration resistance EnclosureCoil rated voltageAllowable voltage fluctuation
Class B or equivalent (130°C) (5)Coil insulation typeApparent power(Power consumption)
Electrical entry
Power consumption
Note 1) Use dry air at low temperatures.Note 2) Use turbine oil Class 1 (ISO VG32), if lubricated.Note 3) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial
direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period)
Note 4) Based on JIS C 0920. Note 5) Based on JIS C 4003.
Val
ve s
pec
ific
atio
ns
Elec
tric
ity s
peci
ficat
ions
AC
Pilot valve manual override
Coil rated voltage
Foot bracket (With screw)
110 to 120, 220, 240 VAC (50/60 Hz)Non-locking push type (Extended), Locking type (Tool reguired)
Pilot type External pilot (1)
12, 100 VDC
Note 1) Operating pressure: 0 to 1.0 MPaPilot pressure: 0.1 to 1.0 MPa
Note 2) Grommet type is available only w/ surge voltage suppressor (which is directly connected with lead wire), not w/ indicator light.
Option With light/surge voltage suppressor (2)
Part no.: VFS3000-52A, VFS3120 (single) only
2 po
sitio
n3
posit
ion
Max. operating
cycle(cpm)
Responsetime(ms)
(Details → P. 1137-2)
Mass(kg)
(1)(2)
(3)
Dustproof (Degrees of protection 0) (4)
1.8 W (2.04 W: With light/surge voltage suppressor)
5 Port Pilot Operated Solenoid ValveMetal Seal, Body Ported
Series VFS3000
Model
1130
VFS.qxd 10.11.25 9:49 AM Page 3
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
How to Order Pilot Valve Assembly
Symbol1: 2 position single
2: position double
3: position closed center
4: position exhaust center
5: position pressure center
F: With foot bracket
Body (Pilot exhaust)20: Individual EXH
30∗: Common EXH
Manual override Nil: Non-locking push type
(Flush)A∗: Non-locking push type
(Extended) B∗: Locking type
(Tool required)
∗ Option
Light/Surge voltage suppressor
RcNPT
NPTFG
∗ Option
∗ Option
∗ Manifold only
Thread type
Option
VFS3 1 20 021 G
Coil rated voltage
Internal pilotNilExternal pilotR∗
Pilot type
Electrical entryT: Conduit terminal D, Y: DIN terminalG: Grommet E: Grommet terminal
0203
Port size
∗ Option
Coil rated voltage Manual overrideApplicable model
SF4 DZ1 21
14
15
16
17
18
19
How to Order
123∗4∗56∗7∗9∗
100 VAC, 50/60 Hz200 VAC, 50/60 Hz
110 to 120 VAC (50/60 Hz)220 VAC, 50/60 Hz
24 VDC12 VDC
240 VAC, 50/60 HzOther
∗ Option
Nil
B∗
A∗
Non-locking pushtype (Flush)
Non-locking pushtype (Extended)Locking type
(Tool required)
Electrical entry, Light/Surge voltage suppressorGrommet
Grommet with surge voltage suppressorDIN terminal
DIN terminal with light/surge voltage suppressorDIN terminal ∗∗
DIN terminal with light/surge voltage suppressor ∗∗DIN terminal
DIN terminal with light/surge voltage suppressorDIN terminal ∗∗
DIN terminal with light/surge voltage suppressor ∗∗Conduit terminal
Conduit terminal with light/surge voltage suppressorGrommet terminal
Grommet terminal with light/surge voltage suppressor
GGSDDZ∗DO∗DOZ∗Y∗
YZ∗
YO∗
YOZ∗TTZEEZ
Individualpilot
exhaust
Commonpilot
exhaust
A side pilot operator for VFS3 20
B side pilot operator for VFS3220
12345
B side pilot operator for VFS3 20345
A side pilot operator for VFS3 30
B side pilot operator for VFS3230
12345
B side pilot operator for VFS3 30345
∗ Grommet type is available only w/ surge voltage suppressor, not w/ indicator light.
NilZ
NoneWith light/surge voltage suppressor
S∗ With surge voltage suppressor
NilN∗T∗F∗
(External pilot port: Body side. For 30 type, common external pilot (on manifold side).)
∗ Reverse pressure: Can be used by external pilot specifications.
∗ Option. It will be an individual ex-ternal pilot.
∗ Mountable only for VFS3120.
Q
CE-compliantNil —
CE-compliant
3∗21
4∗
6∗5
7∗
100 VAC (50/60 Hz)200 VAC (50/60 Hz)
110 to 120 VAC (50/60 Hz)220 VAC (50/60 Hz)
24 VDC12 VDC
240 VAC (50/60 Hz)9∗ Other
Rc 1 4
Rc 3 8
∗ Y: Conforming to DIN43650B standard∗∗ DIN connector is not attached.
1131
Series VFS30005 Port Pilot Operated Solenoid ValveMetal Seal, Body Ported
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
1-2-16-VFS1000.qxd 10.3.29 5:46 PM Page 3
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series
VFS3120-03
Averagespeed(mm/s)
800900
700600500400300200100 0
Bore size
ø6 ø10 ø16 ø20 ø25 ø32 ø40 ø40 ø50 ø63 ø80 ø100 ø125 ø140 ø160
Body Ported
Body ported Series CJ2 Series CM2
AN200-02
Series MB, CA2 Series CS1/CS2
AN202-02
T0604 x 1 mAS3001F-06
T1075 x 1 mAS4001F-10
T1209 x 1 mAS4001F-12
Tube bore x LengthSpeed controllerSilencer
VFS3120-03
Conditions
Cylinder Speed Chart
Series CJ2Pressure 0.5 MPaLoad factor 50%Stroke 60 mm
Series CM2Pressure 0.5 MPaLoad factor 50%Stroke 300 mm
Series MB, CA2Pressure 0.5 MPaLoad factor 50%Stroke 500 mm
Series CS1/CS2Pressure 0.5 MPaLoad factor 50%Cylinder stroke 1000 mm
Use as a guide for selection.Please confirm the actual conditions with SMC Sizing Program.
∗ It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open.
∗ The average velocity of the cylinder is the value that the stroke is divided by the total stroke time.∗ Load factor: ((Load weight x 9.8)/Theoretical force) x 100%
Perpendicular,upward actuationHorizontalactuation
1132
Series VFS3000
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1132
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Construction
2 position single 2 position double
No.
23
1Description Material Note
4
—
—56 —7 —
———
∗ Refer to “How to Order Pilot Valve Assembly” on page 1131.
Component Parts
3 position closed center/exhaust center/pressure centerClosed center
Exhaust center
Pressure center
Stainless steelReturn springPilot valve assembly Detent assembly
Stainless steelResin
Aluminum die-castedSpool/SleeveBody
End plateResinPiston
Black
Platinum silver
1133
Series VFS30005 Port Pilot Operated Solenoid ValveMetal Seal, Body Ported
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1133
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Grommet terminal: VFS3120-�E/EZ
Conduit terminal: VFS3120-�T/TZ
DIN terminal: VFS3120-�D/DZ/Y/YZ
( ): Y, YZ
Foot bracket (F)Part no.: VFS3000-52A
2 Position Single — Grommet, Grommet terminal, Conduit terminal, DIN terminal
Grommet: VFS3120-�G
Manual override(Non-locking)2 x ø4.3 mounting hole M5: External pilot port
(For external pilot model)
2 x ø6 mounting hole
Solenoid valve
≅300
(Lea
d w
ire le
ngth
)
2 x ø4.3 mounting hole
2 x ø4.3 mounting hole
2 x ø4.3 mounting hole
2 x ø4.3 mounting hole
Lead wire O.D.Max. ø3.5
With light/surge voltage suppressor (EZ)
Applicable heavy-duty cordO.D. ø6 to ø8(Y: ø4.7 to ø7)
Light
Light
Light
With light/surge voltage suppressor (DZ)
With light/surge voltage suppressor (TZ)Applicableheavy-duty cordO.D. ø6 to ø8
1134
Series VFS3000
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1134
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Grommet terminal: VFS3220-�E/EZ VFS3320-�E/EZ VFS3420-�E/EZ VFS3520-�E/EZ
Conduit terminal: VFS3220-�T/TZ VFS3320-�T/TZ VFS3420-�T/TZ VFS3520-�T/TZ
( ): Y, YZ
2 Position Double, 3 Position — Grommet, Grommet terminal, Conduit terminal, DIN terminal
Grommet: VFS3220-�G, VFS3320-�G, VFS3420-�G, VFS3520-�G
DIN terminal: VFS3220-�D/DZ/Y/YZ VFS3320-�D/DZ/Y/YZ VFS3420-�D/DZ/Y/YZ VFS3520-�D/DZ/Y/YZ
Manual override(Non-locking)2 x ø4.3 mounting hole
2 x ø4.3 mounting hole
Applicable heavy-duty cordO.D. ø6 to ø8
231 (3 position: 241)
231 (3 position: 241)
With light/surge voltage suppressor (TZ)
2 x ø4.3 mounting hole
M5: External pilot port(For external pilot model)
Lead wire O.D.Max. ø3.5
194 (3 position: 204)
194 (3 position: 204)
With light/surge voltage suppressor (EZ)
Light
2 x ø4.3 mounting hole
Light
2 x ø4.3 mounting hole
Light
Applicable heavy-duty cordO.D. ø6 to ø8 (Y: ø4.7 to ø7)
With light/surge voltage suppressor (DZ)
≅300
(Lea
d w
ire le
ngth
)
1135
Series VFS30005 Port Pilot Operated Solenoid ValveMetal Seal, Body Ported
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1135
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Specifications
Port Specifications
Option
How to Order Manifold BaseVV5FS3-31
Manifold base typeStations Max. 15 stations
Stacking type
PassageSymbol Valve BaseBase
Porting specifications: Rc
Blanking plateSUP block plateEXH block plate
105 03Series VFS3000
Manifold
Symbol
1
Passage Porting specifications3(R2), 5(R1) 1(P)
Stations
Base model
VV5FS3 31
Model Applicable valve model
31
Pilot exhaustPilot common EXH
02
15
RcNPT
NPTFG
∗ Option
Thread type
P, EA, EB port size
2(B), 4(A)
Exploded View of Manifold
Manifold block assemblyVVFS3000-1A-30
Part no. for mounting bolt and gasketBG-VFS3030
03 3 8Rc
Keeps environmental air clean from pilot exhaustUse of the VV5FS3-31 manifold can exhaust intensively the pilot exhaust gas to the base side, and can prevent environmental aggravation due to noise and oil mist. 2(B), 4(A) 3(R2), 5(R1)1(P)
Side:3(R2), 5(R1)
Common1(P)
Common1 3 8 Top: ,14 3 8 Side: 3 8
With gasket, screwAXT636-10A
VVFS3000-10A-1—
AXT636-11A —Note) Individual SUP or EXH is possible with bottom porting of SUP or EXH. For your order, please
indicate it in the manifold specification sheet.
Top
VFS3�30-��-
2 stations
15 stations Rc , Rc1 4 3 8
NilN∗T∗F∗
0203
VFS3�20-��- 0203
Note) Also VFS3�20 is possible to manifold. In this case, it uses an individual pilot exhaust.
• For increasing the manifold bases, please prepare the manifold block assembly no.
•••
••
• Common3 8Rc
Common3 8Rc
Hexagon socket head cap screw: M4 x 53
Gasket
Type 30Type 20
Series VFS3000Manifold SpecificationsStacking Type
How to Order Manifold Assembly [Example]
<Example>(Manifold base)(2 position single)(2 position double)(Blanking plate)
1321
VV5FS3-31-061-03VFS3130-1D-02VFS3230-1D-02VVFS3000-10A-1
Add the valve and option part numbers in order starting from the first station on the D side.
∗∗∗
The asterisk denotes the symbol for assem-bly. Prefix it to the part numbers of the sole-noid valve.
Q
CE-compliantNil —
CE-compliant
1136
1-02-16-VFS1000.qxd 09.11.2 1:31 PM Page 7
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Grommet terminal: E/EZ Conduit terminal: T/TZ DIN terminal: D/DZ/Y/YZ
( ): Y, YZ
Formula for manifold weight M = 0.184n + 0.16 (kg) n: Station
Grommet: G
Type 31 Manifold — Pilot common exhaust: VV5FS3-31- 1-03
27792
LL1
L2
3108123
4139154
5170185
6201216
7232247
8263278
9294309
10325340
FormulaL1 = 31 x n + 15L2 = 31 x n + 30
Stations
n: Station
Rc 1/8External pilot port
4 x ø7 mounting holeBlanking plate
Gasket
Stations
Lead wire O.D.Max. ø3.5
Applicable heavy-duty cordO.D. ø6 to ø8
4 x Rc 1/8PilotEXH port: PE
4 x Rc 1/8PilotEXH port: PE
4 x Rc 1/8PilotEXH port: PE
(With light/surge voltage suppressor: 104.5)
(With light/surge voltage suppressor: 114)
(With light/surge voltage suppressor: 109)
(With light/surge voltage suppressor: 119)
(With light/surge voltage suppressor: 119.5 (121.5))
(With light/surge voltage suppressor: 128.5 (130.5))
3 po
sitio
n (2
04)
Dou
ble
(194
)S
ingl
e (1
35)
3 po
sitio
n (2
41)
Dou
ble
(231
)S
ingl
e (1
53)
Applicable heavy-duty cordO.D. ø6 to ø8(Y: ø4.7 to ø7)
3 po
sitio
n (2
40)
Dou
ble
(230
)S
ingl
e (1
53)
4 x Rc 1/8Pilot EXH port: PE
U side D side
≅300(Lead wire length)
Station
1137
Series VFS30005 Port Pilot Operated Solenoid ValveMetal Seal, Body Ported
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1137
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
VFS2
Symbol1: 2 position single
2: 2 position double
3: 3 position closed center
4: 3 position exhaust center
5: 3 position pressure center
Electrical entryD: DIN terminal
F: With foot bracket
Body (Pilot exhaust)20: Individual EXH
30: Common EXH∗
Manual overrideNil: Non-locking push type
(Flush)A∗: Non-locking push type
(Extended)B∗: Locking type
(Tool required)
∗ Option
NilZ
NoneWith light/surge voltage suppressor
Light/Surge voltage suppressor
NilN∗
RcNPT
NPTFG
T∗F∗
0102
Rc 1 8
Rc 1 4
∗ Option
∗ Option
∗ Reverse pressure: Can be used by external pilot specifications.
∗ Manifold only
∗ Mountable only for VFS2120.
Thread type
Port size
OptionConforming toCSA standard
1 20 0130 1
Coil rated voltage
3∗21
4∗
6∗5
7∗
100 VAC (50/60 Hz)200 VAC (50/60 Hz)
110 to 120 VAC (50/60 Hz)220 VAC (50/60 Hz)
24 VDC12 VDC
240 VAC (50/60 Hz)
Internal pilotNilExternal pilotR∗
Pilot type
Refer to standard products for specifications and dimensions.
How to Order
∗ Option: Individual external pilot (External pilot port: Body side)
1137-1
5 Port Pilot Operated Solenoid ValveMetal Seal, Body Ported
Series VFS2000
VFS.qxd 10.11.25 9:49 AM Page 4
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Symbol1: 2 position single
2: 2 position double
3: 3 position closed center
4: 3 position exhaust center
5: 3 position pressure center
F: With foot bracket
Body (Pilot exhaust)20: Individual EXH
30: Common EXH∗
Manual overrideNil: Non-locking push type
(Flush)A∗: Non-locking push type
(Extended)B∗: Locking type
(Tool required)
∗ Option
NilZ
NoneWith light/surge voltage suppressor
Light/Surge voltage suppressor
RcNPT
NPTFG
NilN∗T∗F∗
∗ Option
∗ Reverse pressure: Can be used by external pilot specifications.
∗ Manifold only
∗ Mountable only for VFS3120.
Thread typeOption
VFS3 1 20 021
Coil rated voltage
Internal pilotNilExternal pilotR∗
Pilot type
∗ Option: Individual external pilot (External pilot port: Body side. For 30 type, common external pilot (on manifold side).)
Electrical entryD: DIN terminal
02 Rc1 403 Rc3 8
Port size
Conforming toCSA standard
30
Refer to standard products for specifications and dimensions.
How to Order
∗ Option
3∗21
4∗
6∗5
7∗
100 VAC (50/60 Hz)200 VAC (50/60 Hz)
110 to 120 VAC (50/60 Hz)220 VAC (50/60 Hz)
24 VDC12 VDC
240 VAC (50/60 Hz)
1137-2
5 Port Pilot Operated Solenoid ValveMetal Seal, Body Ported
Series VFS3000
VFS.qxd 10.11.25 9:49 AM Page 5
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model
Standard Specifications
Option SpecificationsJIS Symbol
Plug-in type
Non plug-in type
Type of actuation
Model
Plug-in Non plug-in
1200
1200
1 4/2(P A/B) 4/2 5/3(A/B R1/R2)Flow characteristics
VFS2300
VFS2400
VFS2500
VFS2310
VFS2410
VFS2100
VFS2200
VFS2110 2.42.52.42.52.32.52.42.52.52.81.21.2
0.160.180.160.180.140.180.150.200.110.17
––
0.550.580.550.580.530.580.540.600.550.63
––
2.82.82.82.82.62.62.72.72.72.71.31.3
0.200.210.200.210.200.230.250.240.200.22
––
0.650.650.650.650.610.620.630.630.620.63
––
VFS2210
VFS2510
VFS2600 VFS2610
1 8
1 8
1 4
1 41 81 41 81 41 81 41 81 4
600
600
600
600
20 or less
20 or less
20 or less
15 or less
13 or less
25 or less
0.43
0.43
0.34
0.42
0.43
0.6
2 position 3 positionSingle Closed center
Double Exhaust center
Pressure center
Double check
Sub-plate
Standard typeCompact type
31.025.5
0.20.13
2.22.8
∗ 2 position single Rc 1/4
Compact yet provides a large flow capacity1/4: C: 2.8 dm3/(s·bar)Low power consumption: 1.8 W DCEasy maintenance2 types of sub-plates: Plug-in and non plug-in
Note 1) Based on JIS B 8375 (Once per 30 days) for the minimum operating frequency. Note 2) Based on JIS B 8375-1981 (The value at supply press. 0.5 MPa).Note 3) Values for VFS2�00-�FZ-01. Note 4) Factors of “Note 1)” and “Note 2)” are ones achieved in controlled clean air.
Single
Double
Double check
Closedcenter
Pressure center
Exhaust center
PortsizeRc C
[dm3/(s·bar)] b CvC
[dm3/(s·bar)] b Cv
FluidMaximum operating pressure
Min. operating pressure
InrushHolding
2 position3 position
Grommet terminal, DIN terminalConduit terminal
Ambient and fluid temperatureProof pressure
LubricationPilot valve manual overrideShock/Vibration resistance
Enclosure
Coil rated voltageAllowable voltage fluctuationCoil insulation typeApparent power(Power consumption)
Electrical entryPlug-in type
Non plug-in type
Power consumption DC
Note 1) Use dry air at low temperatures.Note 2) Use turbine oil Class 1 (ISO VG32), if lubricated.Note 3) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and
at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period)
Note 4) Based on JIS C 0920. Note 5) Based on JIS C 4003.
Val
ve s
pec
ific
atio
ns
Elec
tric
ity s
peci
ficat
ions
Air/Inert gas1.0 MPa0.1 MPa0.15 MPa
–10 to 60°C (1)
Non-lube (2)
Non-locking push type (Flush)150/50 m/s2 (3)
Type G, E: Dustproof (Class 0), Type F, T, D: Splashproof (Class 4) (4)
100, 200 VAC, 50/60 Hz; 24 VDC–15 to +10% of rated voltage
5.6 VA/50 Hz, 5.0 VA /60 Hz3.4 VA (2.1 W)/50 Hz, 2.3 VA (1.5 W)/60 Hz
1.5 MPa
Class B or equivalent (130°C) (5)
1.8 W (2.04 W: With light/surge voltage suppressor)
AC
Manual override
Coil rated voltage
Option
110 to 120, 220, 240 VAC, 50/60 HzNon-locking push type (Extended), Locking type (Tool required), Locking type (Lever)
Pilot type External pilot Note)
12, 100 VDC
Note) Operating pressure: 0 to 1.0 MPa Pilot pressure 2 position: 0.1 to 1.0 MPa 3 position: 0.15 to 1.0 MPa
Porting specificationsWith light/surge voltage suppressor
Bottom ported
L (mm)
Mass(kg)
Sonic conductance ∗ C [dm3/(s·bar)]
Compact, lightweight type sub-plateCompared with the standard type, this is the sub-plate having the reduced external dimensions and lighter weight. But, use caution that Cv factor or piping port position is different from the standards. For details, refer to page 1161.
2 po
sitio
n3
posi
tion
Max. operating
cycle(cpm)
(Details → P. 1222-1)
Responsetime(ms)
Mass(kg)
(1)(2)
(3)
1138
5 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
Series VFS2000
VFS.qxd 10.11.25 9:49 AM Page 6
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
How to Order Pilot Valve Assembly
2
2
00 01FVFS2 5
1 E10VFS2
Symbol
1
2 position single
2
2 position double
3
3 position closed center
4
3 position exhaust center
5
3 position pressure center
6
3 position double check
O: Plug-in typesub-plate
Body type
OptionNilZ
NoneWith light/surge voltage suppressor
Porting specificationsNilB∗
OptionNilZS∗
Thread type
Port sizeNil
01
Without sub-plate
02
Coil rated voltage
Body type
Pilot type
∗ Option
Electrical entryG: Grommet
1: Non plug-in typesub-plate
E: Grommet terminal T: Conduit terminal D, Y: DIN terminal
∗ Option
Pilot valve manual override
NilR∗
02
Plug-in
Non plug-in 2
F: Plug-in type
Electrical entry
Port sizeNil
01Rc Non plug-in type,
Standardtype
Without sub-plate
1 8
1 402
Rc
Non plug-in type,Compacttype
1 8
1 4
Note)
Note)S01
Rc
S02Rc
Note)
Note)
P01
P02
123∗4∗56∗7∗9∗
∗ Option∗ Option
Coil rated voltage
SF4 DZ1 20Electrical entry, Light/Surge voltage suppressor
GGS
F
DDZDODOZYYZ
YOYOZTTZEEZ
How to Order
Side portedBottom ported
NoneWith light/surge voltage suppressor
With surge voltage suppressor
RcNPT
NPTFG
NilN∗
T∗
F∗
∗ Option
∗ Option
Rc Plug-in type conduit terminal(With terminal block)Standard type
1 8
Rc 1 4
123∗4∗56∗
9∗
100 VAC, 50/60 Hz200 VAC, 50/60 Hz
110 to 120 VAC, 50/60 Hz220 VAC, 50/60 Hz
24 VDC12 VDC
7∗ 240 VAC, 50/60 HzOther
∗ Option: External pilot is possible only to the one with sub-plate.
Nil: Non-locking push type(Flush)
B∗: Locking type(Tool required)
A∗: Non-locking push type(Extended)
C∗: Locking type(Lever)
Internal pilotExternal pilot
Plug-in type grommet(With attachment plug lead wire)Compact type
Rc 1 8
Rc 1 4
Note) Please note Cv factor and piping port location of compact sub-plate is different from standard. Refer to page 1161 for details.
Note) Please note Cv factor and piping port location of compact sub-plate are different from standard. Refer to page 1161 for details.
100 VAC, 50/60 Hz200 VAC, 50/60 Hz110 to 120 VAC (50/60 Hz)
220 VAC, 50/60 Hz24 VDC12 VDC
240 VAC, 50/60 HzOther
Nil
B∗
A∗
Non-lockingpush type
(Flush)
Non-lockingpush type
(Extended)
Locking type(Tool required)
C∗ Locking type(Lever)
Manualoverride
Grommet
Plug-in Plug-in
Non plug-in
Grommet with surge voltage suppressorDIN terminal
DIN terminal with light/surge voltage suppressorDIN terminal∗
DIN terminal with light/surge voltage suppressor∗
DIN terminalDIN terminal with light/surge voltage suppressor
∗ DIN connector is not attached.∗∗ Refer to page 1223 for voltage conversion.∗∗∗ Y: Conforming to DIN43650B standard
Non plug-in
DIN terminal∗
DIN terminal with light/surge voltage suppressor∗
Conduit terminalConduit terminal with light/surge voltage suppressor
Grommet terminalGrommet terminal with light/surge voltage suppressor
With attachment plug lead wire
With terminal block
∗ Grommet type is available only w/ surge voltage suppressor, not w/ indicator light.
Q
CE-compliantNil —
CE-compliant
1139
Series VFS20005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
∗ Combining double check spacer with external pilot will not work.
∗
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
1-2-16-VFS1000.qxd 10.3.29 5:46 PM Page 4
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
System Components
System
A
800700600500400300200100 0
B
800700600500400300200100 0
Bore size
ø20 ø25 ø32 ø40 ø40 ø50 ø63 ø80 ø100 ø125 ø140 ø160
A
B
Double Check Spacer/Specifications
Double checkspacer part no.
Applicable valve model
Specifications Check Valve Operating
Caution
Cylinder Speed Chart
Can hold an intermediate cylinder position for an extended timeIf the double check spacer with a built-in double check valve is combined, it will en-able the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools.
• The combination of VFS21 0, VFS22 0 and a double check spacer can be used as prevention of falling at the stroke end but cannot hold the intermediate position of the cylinder.
SeriesVFS2000
AN110-01(S = 35 mm2)
AS3000-02(S = 12 mm2)
Tube bore x Length
T0604 x 1 m
T1075 x 1 m
System Solenoid valve Speed controller
Silencer
1 8
SeriesVFS2000
AN110-01(S = 35 mm2)
AS4000-02(S = 21 mm2)
Plug-in type Non plug-in type
VVFS2000-22A-1 VVFS2000-22A-2
VFS2400-�F VFS2410-�GETD
Double check spacer
Averagespeed(mm/s)
Series CMPressure 0.5 MPaLoad factor 50%Stroke 300 mm
Series MB, CA2Pressure 0.5 MPaLoad factor 50%Stroke 500 mm
Series CS1/CS2Pressure 0.5 MPaLoad factor 50%Cylinder stroke 1000 mm
Use as a guide for selection.Please confirm the actual conditions with SMC Sizing Program.
∗ It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open.
∗ The average velocity of the cylinder is the value that the stroke is divided by the total stroke time.
∗ Load factor: ((Load weight x 9.8)/Theoretical force) x 100%
Perpendicular,upward actuationHorizontalactuation
Rc
1 4Rc
Cylinder pressure Check valve
Operating range
Cylinder pressure P2 (MPa)
Piston SUP side pressure (P1)• In the case of 3 position double check valve (VFS26�0), check the leakage from piping and fittings in between valve and cylinder by means of synthetic detergent solutions, and ensure that there is no such leakage found there. Also check the leakage from cylinder seal and piston seal. If there is any leakage, sometimes the cylinder, when valve is de-energized, can move without stopping at intermediate position.
• Be aware that if the exhaust side is restricted excessively, the intermediate stopping accuracy will decrease and will lead to improper intermediate stops.
• Combining double check spacer with external pilot will not work.
01
01
SU
P s
ide
pres
sure
P1
(MP
a)
1140
Series VFS2000
1-2-16-VFS1000.qxd 09.8.3 5:06 PM Page 3
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Construction
Component Parts Sub-plate Assembly (Standard) Part No.
2 position single 2 position double
No.
23
1Description Material Note
4—
56 —7 —8 —9 —10 —11 —12 — —13 — —
∗ Refer to “How to Order Pilot Valve Assembly” on page 1139.
Plug-in
Non plug-in
Plug-in
Non plug-in
Sub-plate Assembly (For External Pilot) Part No.
∗ Mounting bolt and gasket are not included.
Part no. for mounting bolt and gasketBG-VFS2000-1
3 position closed center/exhaust center/pressure center
Closed center
Exhaust center
Pressure
Aluminum die-castedStainless steel
Aluminum die-castedSub-plateBody
Spool/SleeveResinAdapter plate
Platinum silverPlatinum silver
BlackResinEnd plate BlackResinPistonResinJunction coverResinCover
HNBRStainless steelReturn spring
GasketSteelHexagon socket head screw
Detent assemblyPilot valve assembly
VFS2000-LP-
VFS2000-LS-
0102
0102
VFS2000-LP-R
VFS2000-LS-R
0102
0102
1141
Series VFS20005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
251-VFS.qxd 10.12.27 1:20 PM Page 1
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
( ): Rc 1 8 ( ): Rc 1 8
( ): Rc 1 8
Plug-in — 2 Position single/Double/3 Position closed center/Exhaust center/Pressure center/Double check
2 position single: VFS2100-�F-0102
2 position double: VFS2200-�F-0102
3 position closed center: VFS2300-�F-0102
3 position exhaust center: VFS2400-�F-0102
3 position pressure center: VFS2500-�F-0102
3 position double check: VFS2600-�F-0102
Manual override(Non-locking)
2 x ø5 mounting hole
Manual override(Non-locking)
2 x ø5 mounting hole
Manual override(Non-locking)
2 x ø5 mounting hole
Electrical entry
With light/surge voltage suppressor
With light/surge voltage suppressor
With light/surge voltage suppressor
1(P), 4(A), 2(B) bottom ported
3(R2), 5(R1) bottom ported
Bottom ported
(External pilot port)
Pilot EXH port
150.5 (3 position: 158)
163.5 (3 position: 171)
3 x Rc , 1 8 1 4
2 x Rc 1 8
1142
Series VFS2000
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1142
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
( ): Y, YZ
Non Plug-in — 2 Position single Grommet: VFS2110-�G-01
02
Grommet terminal: VFS2110-�E-0102
Conduit terminal: VFS2110-�T-0102
DIN terminal: VFS2110-�DY-01
02
( ): Rc 1 8
Manual override(Non-locking)
2 x ø5 mounting hole 1(P), 4(A), 2(B) bottom ported
3(R2), 5(R1) bottom ported
Bottom ported
Pilot EXH port M5 x 0.8
A, B
Lead wire O.D. Max. ø3.5 With light/surge voltage suppressor
With light/surgevoltage suppressor
Applicable heavy-duty cordO.D. ø6 to ø8
Light
Light
Applicable heavy-duty cordO.D. ø6 to ø8(Y: ø4.7 to ø7)
(External pilot port M5 x 0.8)
≅300
(Lea
d w
ire le
ngth
)
3 x Rc , 1 8 1 4
2 x Rc 1 8
With light/surge voltage suppressor
Light
1143
Series VFS20005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1143
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
( ): Y, YZ
Non Plug-in — 2 Position double/3 Position closed center/Exhaust center/Pressure center Grommet: Double VFS2210-�G-01
02Closed center VFS2310-�G-01
02, Exhaust center VFS2410-�G-0102, Pressure center VFS2510-�G-01
02
1 8( ): Rc
Grommet terminal: Double VFS2210-�E-0102
Closed center VFS2310-�E-0102
Exhaust center VFS2410-�E-0102
Pressure center VFS2510-�E-0102
Conduit terminal: Double VFS2210-�T-0102
Closed center VFS2310-�T-0102
Exhaust center VFS2410-�T-0102
Pressure center VFS2510-�T-0102
DIN terminal: Double VFS2210-�DY-01
02 Closed center VFS2310-�D
Y-0102
Exhaust center VFS2410-�DY-01
02Pressure center VFS2510-�D
Y-0102
Manual override(Non-locking)
150.5 (3 position: 158)2 x ø5mounting hole
≅300
(Lea
d w
ire le
ngth
)
1(P), 2(B), 4(A) bottom ported
3(R2), 5(R1) bottom ported
Bottom ported
Pilot EXH port M5 x 0.8
With light/surge voltage suppressor
With light/surge voltage suppressor
Lead wire O.D. Max. ø3.5
151 (3 position: 159)
Light
With light/surge voltage suppressor (DZ)
Applicable heavy-duty cord
Light
Applicableheavy-duty cord
187.5 (3 position: 195)
187.5 (3 position: 195)
(External pilot port M5 x 0.8)
3 x Rc , 1 8 1 4
2 x Rc 1 8
O.D. ø6 to ø8(Y: ø4.7 to ø7)
O.D. ø6 to ø8
Light
1144
Series VFS2000
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1144
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
( ): Y, YZ
Non Plug-in — 3 Position double check
Grommet terminal: VFS2610-�E-0102 DIN terminal: VFS2610-�D
Y-0102
1 8( ): Rc
Bottom ported
Grommet: VFS2610-�G-0102
Conduit terminal: VFS2610-�T-0102
Manual override(Non-locking)
2 x ø5 mounting hole
≅300
(Lea
d wi
re le
ngth
)
3 x Rc 1/8, 1/41(P), 2(B), 4(A) bottom ported2 x Rc 1/83(R2), 5(R1) bottom ported
(External pilot port)(M5 x 0.8)
Pilot EXH portM5 x 0.8
Lead wire O.D. Max. ø3.5
Applicableheavy-duty code
With light/surge voltage suppressor
With light/surge voltage suppressor (DZ)
Light
Applicableheavy-duty code
Light
With light/surge voltage suppressor
Light
O.D. ø6 to ø8
O.D. ø6 to ø8(Y: ø4.7 to ø7)
1145
Series VFS20005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1145
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Plug-in Type: With Attachment Plug Lead Wire
Plug-in Type: With Terminal Block
Non Plug-in Type: Grommet, Grommet Terminal, Conduit Terminal, DIN Terminal• Wiring for every valve
Plug-in typeWith attachment plug lead wire
Series VFS2000Manifold
Symbol
∗ Option
Symbol
12∗
SideBottom
Passage Portingspecifications
A, B EA, EBP
CommonCommon
3∗4∗
SideBottom
IndividualCommon
5∗6∗
SideBottom
CommonIndividual
7∗8∗
SideBottom
IndividualIndividual
NilN∗
RcNPT
NPTFG
T∗F∗
Thread type
∗ Option
2 stations
16 stations
02
16
Stations
01VV5FS2 106 01
Port sizeSymbol0102
A, BP, EA, EB
RcRcRc
M Mixed1 41 4
1 8
∗ For bottom ported, Rc 1/8 is only available.
Q
CE-compliantNil —
CE-compliant
The insert plug is attached to the manifold block and lead wire is plugged into the valve side. Please connect with corresponding power side.
Since lead wires of solenoid valve are connected with the terminals on upper surface of terminal block, corresponding lead wires from power source can be wired at the bottom of terminal block.
Note) The individual specification of the P port at the composition symbol 3 to 8 or the EA, EB, ports should be taken as individual port using a block plate. Therefore, if an individual port is using a single SUP spacer of option or a single EXH spacer, the composition symbol mark is “1”.
• Wide range of interchangeability(D-sub connector (25P) conforming to MIL standard)
• Quick wiring permits easier installation.
VV5FS2 108 02Series
VFS2000Manifold
01T 1Plug-in type
With terminal block
Nil
1
Separate junctioncover
One-piece junctioncover
Q
CE-compliantNil —
CE-compliant
NilN∗
RcNPT
NPTFG
T∗F∗
Thread type
∗ Option
Port sizeSymbol0102
A, BP, EA, EB
RcRcRc
M Mixed1 41 4
1 8
∗ For bottom ported, Rc 1/8 is only available.
Symbol
∗ Option
Symbol
12∗
SideBottom
Passage Portingspecifications
A, B EA, EBP
CommonCommon
3∗4∗
SideBottom
IndividualCommon
5∗6∗
SideBottom
CommonIndividual
7∗8∗
SideBottom
IndividualIndividual
Junction cover
2 stations
16 stations
02
16
Stations
VV5FS2 205 01
∗ Max. 8 stations
01C 1DPlug-in type
With multi-connectorSeries
VFS2000Manifold
D side mountingU side mounting
DU
Connector mounting direction
1 One-piece junctioncover
Junction cover
2 stations
8 stations
02
08
Stations
Q
CE-compliantNil —
CE-compliant
NilN∗
RcNPT
NPTFG
T∗F∗
Thread type
∗ Option
Symbol
∗ Option
Symbol
12∗
SideBottom
Passage Portingspecifications
A, B EA, EBP
CommonCommon
3∗4∗
SideBottom
IndividualCommon
5∗6∗
SideBottom
CommonIndividual
7∗8∗
SideBottom
IndividualIndividual
Port sizeSymbol0102
A, BP, EA, EB
RcRcRc
M Mixed1 41 4
1 8
∗ For bottom ported, Rc 1/8 is only available.
With attachment plug lead wire
One-piece junction cover
Individual junction cover Conduit port
PlugassemblyRefer to page 1227.
Plug assemblyRefer to page 1227.
Multi-connector
D-sub connector
U side
U side
D side
D side
Plug-in Type: With Multi-connector (Wiring specifications: Refer to page 1227.)
Plug-in Type: With D-sub Connector (Wiring specifications: Refer to page 1227.)
VV5FS2 106 0101F 1UPlug-in type
With D-sub connectorSeries
VFS2000Manifold
∗ Max. 8 stations
D side mountingU side mounting
DU
Connector mounting direction
1 One-piece junctioncover
Junction cover
2 stations
8 stations
02
08
Stations
Q
CE-compliantNil —
CE-compliant
NilN∗
RcNPT
NPTFG
T∗F∗
Thread type
∗ Option
Symbol
∗ Option
Symbol
12∗
SideBottom
Passage Portingspecifications
A, B EA, EBP
CommonCommon
3∗4∗
SideBottom
IndividualCommon
5∗6∗
SideBottom
CommonIndividual
7∗8∗
SideBottom
IndividualIndividual
Port sizeSymbol0102
A, BP, EA, EB
RcRcRc
M Mixed1 41 4
1 8
∗ For bottom ported, Rc 1/8 is only available.
10VV5FS2
Non plug-in type
205 01Series VFS2000
Manifold
2 stations
16 stations
02
16
Stations
Symbol
∗ Option
Symbol
12∗
SideBottom
Passage Portingspecifications
A, B EA, EBP
CommonCommon
3∗4∗
SideBottom
IndividualCommon
5∗6∗
SideBottom
CommonIndividual
7∗8∗
SideBottom
IndividualIndividual
Q
CE-compliantNil —
CE-compliant
NilN∗
RcNPT
NPTFG
T∗F∗
Thread type
∗ Option
Port sizeSymbol0102
A, BP, EA, EB
RcRcRc
M Mixed1 41 4
1 8
∗ For bottom ported, Rc 1/8 is only available.
• Master connection of power and solenoid valves.• Quick wiring permits ease of installation.
1146
Series VFS2000Manifold Specifications
1-02-16-VFS1000.qxd 09.11.2 1:31 PM Page 9
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Base model
Plug-in typeVV5FS2-01�
Non plug-in typeVV5FS2-10
Wiring
• With attachment plug lead wire• With terminal block• With multi-connector• With D-sub connector• Grommet• Grommet terminal• Conduit terminal• DIN terminal
A, B port P, EA, EBPort size Rc
A, BStations
∗ With multi-connector, with D-sub connector: 8 stations at the maximum.
Manifold Specifications
Flow Characteristics at the Number of Manifold Stations (Operated individually)
C [dm3/(s·bar)]b
Cv
Passage/Stations Station 1 Station 5 Station 10
bC [dm3/(s·bar)] 2.4
0.140.502.5
0.180.60
2.40.140.502.5
0.180.60
2.40.140.502.50.180.60
Cv
Model
VVFS2
Please indicate manifold base type, corresponding valve, and option parts.
<Example>• Plug-in type with terminal block
(6 stations, one-piece style junction cover)(Manifold base) VV5FS2-01T1-061-02····1(2 position single) VFS2100-5FZ············3(2 position double) VFS2200-5FZ···········2(Blanking plate) VVFS2000-10A············· 1
• Non plug-in type (6 stations)(Manifold base) VV5FS2-10-061-01········ 1(2 position single) VFS2110-5D············· 3(3 position exhaust center) VFS2410-5D····· 1(Individual EXH spacer) VVFS2000-R-01-2···1
How to Order Manifold AssemblyPorting
specifications
Side/Bottom 1 4 1 8 1 4 2 to 15∗stations
Applicable valve model
VFS2�00-�F
VFS2�10-�GVFS2�10-�EVFS2�10-�TVFS2�10-�D
,
4/2 5/3(A/B R1/R2)
1 4/2(P A/B)
∗ Port size Rc 1 4
1147
Series VFS20005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1147
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Manifold Option Parts Assembly
Dripproof ManifoldPlug-in type• Equivalent to IP65
For details, refer to page 1153.
For details, refer to page 1155.
For details, refer to page 1158.
Made to OrderManifold with serial transmission kit Plug-in type• Solenoid valve wiring process reduced
considerably.
Individual SUP spacerAn individual SUP spacer set on manifold block can form SUP port for every valve.
Individual EXH spacerAn individual EXH spacer set on manifold block can form EXH port for every valve. (Common EXH type)
SUP block plateWhen supplying manifold with more than two different pressures, high and low, insert a block plate in between stations subjected to different pressures.
EXH block plateWhen valve exhaust affects the other stations on the circuit or when the reverse pressure valve is used to standard manifold valve, insert EXH block plate in between stations to separate valve exhaust.
Double check spacerIf the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools.
Body type
Part
no.
Rc 1 8
Plug-in typeVVFS2000-P-01-1
Non plug-in typeVVFS2000-P-01-2
Rc 1 4 VVFS2000-P-02-1 VVFS2000-P-02-2
Body type Plug-in typeARBF2000-00-P-1
Non plug-in typeARBF2000-00-P-2P port regulation Body type Plug-in type
VVFS2000-10ANon plug-in type
Part no.
Body type
Part
no.
Rc 1 8
Plug-in typeVVFS2000-R-01-1
Non plug-in typeVVFS2000-R-01-2
Rc 1 4 VVFS2000-R-02-1 VVFS2000-R-02-2
Body type Plug-in typeVVFS2000-21A-1
Non plug-in typeVVFS2000-21A-2Part no.
Body type Plug-in typeAXT625-12A
Non plug-in typePart no. Body type Plug-in type
VVFS2000-24A-1 Non plug-in typeVVFS2000-24A-2 Part no. L
RLR
Note) L: U side mount R: D side mount
Body type Plug-in typeAXT625-12A
Non plug-in typePart no.
Body type Plug-in typeVVFS2000-20A-1
Non plug-in typeVVFS2000-20A-2Part no. Body type Plug-in type
VVFS2000-22A-1Non plug-in typeVVFS2000-22A-2Part no.
Air shutoff valve spacerWhen stopping supply air and releasing residual pressure after completion of work, actuators may move from original position. Air shut off valve spacer makes it possible to stop actuators in original position for extended periods.
Air release valve spacerThe concurrent use of air release valve spacer with VFS21�0 (single) can release air.
∗ Not mountable for standard type sub-plate.
AccessoryOne pair of gasket and mounting thread is attached to every option parts assembly.
With control unitPlug-in type/Non plug-in type• Filter, regulation valve, pressure switch
and air release valve are all combined to form one unit.
• Piping processes are eliminated.
Blanking plateIt is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc.
Throttle valve spacerNeedle valve set on the manifold block can control cylinder speed by throttling exhaust.
Manifold Option
Interface regulator (P port regulation)Interface regulator set on manifold block can regulate the pressure to each valve. Refer to “Flow Characteristics” on page 1225.
1148
Series VFS2000
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1148
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Formula for manifold weight M = 0.201n + 0.299 (kg) n: Station
Manifold — Plug-in type, Non plug-in type
StationsL
L1
L2
17584
2103112
3131140
4159168
5187196
6215224
7243252
8271280
9299308
10327336
FormulaL1 = 28 x n + 47L2 = 28 x n + 56
n: StationsFormula for manifold weight M = 0.174n + 0.218 (kg)
2(B), 4(A) port
2(B), 4(A) port
Stations
Stations
2(B), 4(A) port
2(B), 4(A) port
With light/surge voltage suppressor
1(P), 3(R2), 5(R1) port
1(P), 3(R2), 5(R1) port
≅300
mm
(Lea
d w
ire le
ngth
)
Pilot EXH port
Pilot EXH port
Electrical entry
Station Port sizePlug-in type (Insert plug with lead wire): VV5FS2-01- 1-
Station Port sizeBottom ported:
VV5FS2-01- 2-
Station Port sizeNon plug-in type: VV5FS2-10- 1-
Station Port sizeVV5FS2-10- 2-
U side
D side
U side
D side
Bottom ported:
1149
Series VFS20005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1149
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Formula for manifold weight M = 0.215n + 0.35 (kg) n: Station
Manifold — Plug-in type: Individual/One-piece junction cover
Bottom ported:
Formula for manifold weight M = 0.236n + 0.354 (kg) Stations
L
L1
L2
17584
2103112
3131140
4159168
5187196
6215224
7243252
8271280
9299308
10327336
FormulaL1 = 28 x n + 47L2 = 28 x n + 56
Bottom ported:
2(B), 4(A) port
Stations
2(B), 4(A) port
With light/surge voltage suppressor
1(P), 3(R2), 5(R1) port
Pilot EXH port
Electrical entry
2(B), 4(A) port
Stations
2(B), 4(A) port
With light/surge voltage suppressor
1(P), 3(R2), 5(R1) port
Pilot EXH port
Electrical entry
Station Port sizePlug-in type with terminal block (Individual junction covers): VV5FS2-01T- 1-
Station Port sizeVV5FS2-01T- 2-
Station Port sizePlug-in type with terminal block (One-piece junction covers): VV5FS2-01T1- 1-
Station Port sizeVV5FS2-01T1- 2-
n: Station
U side
D side
U side
D side
1150
Series VFS2000
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1150
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Formula for manifold weight M = 0.211n + 0.442 (kg) n: Station∗ Wiring specifications: Refer to page 1227.
Manifold — Plug-in with multi-connector/with D-sub connector
Plug-in type with D-sub connector: VV5FS2-01FD1- 1- , VV5FS2-01FU1- 1-
StationsL
L1
L2
17584
2103112
3131140
4159168
5187196
6215224
7243252
8271280
FormulaL1 = 28 x n + 47L2 = 28 x n + 56
n: Stations
Bottom ported:
Formula for manifold weight M = 0.178n + 0.378 (kg) ∗ Wiring specifications: Refer to page 1227.
Bottom ported:
2(B), 4(A) port
Plug assembly: VVFS2000-30A-�(Option: Refer to page 1227.)
Plug assembly: VVZS3000-21A-�(Option: Refer to page 1227.)
Stations
Stations
Pilot EXH port
1(P), 3(R2), 5(R1) port
With light/surge voltage suppressor
With light/surge voltage suppressor
2(B), 4(A) port
2(B), 4(A) port
2(B), 4(A) port
1(P), 3(R2), 5(R1) port
Pilot EXH port
Plug-in with multi-connector: VV5FS2-01CD1- 1- , VV5FS2-01CU1- 1- Station Port size Station Port size
Station Port sizeVV5FS2-01CD1CU1- 2-
Station Port sizeVV5FS2-01FD1FU1- 2-
Station Port size Station Port size
U side
D side
U side
D side
1151
Series VFS20005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1151
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Manifold Option Parts — Plug-in type, Non plug-in type
Individual SUP spacer:VVFS2000-P-01
02-1 (Plug-in type)VVFS2000-P-01
02-2 (Non plug-in type)
Individual EXH spacer:VVFS2000-R-01
02-1 (Plug-in type)VVFS2000-R-01
02-2 (Non plug-in type)
SUP block plate: AXT625-12AEXH block plate: AXT625-12A
Throttle valve spacer:VVFS2000-20A-1 (Plug-in type)VVFS2000-20A-2 (Non plug-in type)
Release valve spacer:VVFS2000-24A-1R
L (Plug-in type)VVFS2000-24A-2R
L (Non plug-in type)
Double check spacer:VVFS2000-22A-1 (Plug-in type)VVFS2000-22A-2 (Non plug-in type)
Interface regulator:ARBF2000-00-P-1 (Plug-in type)ARBF2000-00-P-2 (Non plug-in type)
Air shutoff valve spacer:VVFS2000-21A-1 (Plug-in type)VVFS2000-21A-2 (Non plug-in type)
Note) VVFS2000-24A-12 R. D-side mounting.12
Individual SUP spacer
Interface regulator
Individual EXH port
Block plate
Throttle valve spacer
Release valve spacer
Valve VFS21�0 (Single)
SUP port
Double check spacer
EXH port
Air shutoff valve spacer
SUP port
1152
Series VFS2000
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1152
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Manifold Specifications
Control Unit Specifications Control Unit/Option
CautionWhen using an air filter with auto-drain or manual drain, mount the filter vertically.
VV5FS2 10 08 1 01 APSeries VFS2000
Manifold
Control unit type
Air release valve coil rating
Q
CE-compliantNil —
CE-compliant
Nil159
0101T01C01F10
Symbol Applicable base
DNil
U01C, 01F
01, 01T, 10
With connector
D side mountingNone
U side mounting
Connector mounting direction
Base type/Electrical entry
Port size
Thread type
How to Order Note) The manifold of plug-in type with attachment plug lead wire is applied to individual type only. Non plug-in type has no junction cover.
How to Order Manifold Assembly [Example]Add the valve and option part numbers in order starting from the first station on the D side.
Manifold with Control Unit
Manifold
Wiring
Applicable valve model
Porting specificationsRc
Stations
Plug-in type: VV5FS2-01� Non plug-in type: VV5FS2-10Plug-in with attachment plug lead wire
With terminal blockWith multi-connectorWith D-sub connector
GrommetGrommet terminalConduit terminal
DIN terminal
VFS2�00-�FVFS2�10-�G, VFS2�10-�EVFS2�10-�T, VFS2�10-�D
Common SUP, Common EXHSide: Rc 1/8, 1/4, Bottom: Rc 1/8 (Option)
Side: Rc 1/4, 1/8, Bottom: Rc 1/8 (Option)2 to 15 stations∗
∗ With multi-connector, or D-sub connector: 8 stations max.
2(B), 4(A) port1 (P), 3(R2), 5(R1) port
• Control unit (Filter, Regulator, Pressure switch, Air release valve) are all standardized to the one unit, and can be mounted on the manifold base without any attachments.
• Piping processes are eliminated.
Plug-in type
Non plug-in type
Air filter (With auto-drain/With manual drain)Filtration degreeRegulatorSet pressure (Outlet pressure)Pressure switch (1)
Set pressure range: OFFDifferentialContact
Max. switch capacity
Max. operating current
Air release valve (Single only)Operating pressure range
5 µm
0.05 to 0.85 MPa
0.1 to 0.6 MPa
0.1 to 1.0 MPa
0.08 MPa or less1a
Indicator light LED (RED)2 VA AC, 2 W DC
24 VAC/DC or less: 50 mA100 VAC/DC: 20 mA
Air releasevalve spacer
Pressure switch (3)
Blankingplate
Filter element
<Plug-in type>VVFS2000-24A-1R (D side mounting)VVFS2000-24A-1L (U side mounting)<Non plug-in type>VVFS2000-24A-2R (D side mounting)VVFS2000-24A-2L (U side mounting)
IS1000P-2-1With control unit/Filter regulator
Pressure switchRelease valve
MP2-2MP3-2
AXT625-18A111511-5B
Note 1) Voltage: 24 VDC to 100 VACInner voltage drop: 4 V
Note 2) Refer to manifold option parts on page 1148.
Note 3) The non plug-in type cannot be mounted afterwards.
Air filter with auto-drainControl equipment
Symbol
Air filter with manual drainRegulatorAir release valvePressure switchBlanking plate (Air release valve)
Blanking plate (Pressure switch)
Number of manifold blocksrequired for mounting (stations)
2
Blanking plate (Filter, Regulator)
2 2 2 2 2 2 1
Nil A AP M MP F G C E
None (F, G type only)100 VAC, 50/60 Hz
24 VDCOther
Plug-in type with attachment plug lead wirePlug-in type with terminal block
Plug-in type with multi-connectorPlug-in type with D-sub connector
Non plug-in type
2 stations
15 stations
02
15∗
Stations
Stacking typeIntegrated type
Nil1
Junction cover
∗ Base type01, 01T, 10 2 to 15 stations01C, 01F 2 to 8 stations
(Manifold base)(2 position single)
Symbol
Symbol
1 Side2∗ Bottom3∗ Side4∗ Bottom5∗ Side6∗ Bottom7∗ Side8∗ Bottom
Passage Portingspecifications
B, AEA, EBP
CommonCommon
IndividualCommon
CommonIndividual
IndividualIndividual
<Example>• Plug-in type with terminal block(Manifold base)(2 position single)(2 position double)∗ 2 stations are needed to mount control unit.
• Non plug-in type
∗ 2 stations are needed to mount control unit.
152
15
VV5FS2-01T1-091-02-MP5VFS2100-5FZVFS2200-5FZ
VV5FS2-10-071-01-MVFS2110-5D
The individual specification of the P port in the composition symbol marks 3 to 8 or EA, EB ports should be taken as individual port using a block plate. Therefore, if an individual port is taken using a single SUP spacer of option or a single EXH spacer, the composition symbol mark is “1”.
Note) Stacking type:Base type 01, 01TIntegrated type:Base type 01T, 01C, 01F
∗ Option
Symbol
0102
B, AP, EA, EB
RcRc Rc
M Mixed
1 41 4
1 8
NilN∗
RcNPT
NPTFG
T∗F∗
∗ Option
··· ···
(2)
The asterisk denotes the symbol for assembly. Prefix it to the part numbers of the solenoid valve.
∗ ∗
∗
1153
Series VFS20005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
1-02-16-VFS1000.qxd 09.11.2 1:31 PM Page 10
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Example for manifold
Manifold with Control Unit — Plug-in type, Non plug-in type
Plug-in type:Example for manifold
StationsL
L1
L2
3131140
4159168
5187196
6215224
7243252
8271280
9299308
10327336
FormulaL1 = 28 x n + 47L2 = 28 x n + 56
L3 (MP) 278 306 334 362 390 418 446 474 L3 = 28 x n + 194L3 (AP) 319.5 347.5 375.5 403.5 431.5 459.5 487.5 515.5 L3 = 28 x n + 235.5
n: Stations
Stations
Stations
Pressure switch
Pressure switch
With light/surgevoltagesuppressor
Control unit
Pilot EXH port
Pilot EXH port
Electrical entry
Pressure switchelectrical entry
Po port
Po port
1(P), 3(R2), 5(R1) port
Control unit
Outlet for check
Individual SUP spacer
Double check spacer
Individual EXH spacer
Air
rele
ase
valv
eA
ir fil
ter
regu
lato
r
Control unit
Outlet for check
Individual SUP spacer
Double check spacer
Individual EXH spacer
Air
rele
ase
valv
eA
ir fil
ter
regu
lato
r
Pressure switch
Air release valve
A, B port
Non plug-in type:
Station Port size Control unit Voltage for release valveVV5FS2-01T- 1- -
Station Port size Control unit Voltage for release valveVV5FS2-10- 1- -
Pressure switch
1(P), 3(R2), 5(R1) port
U side
D side
U side
D side
Air release valve
1154
Series VFS2000
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1154
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Dripproof Manifold (Equivalent to IP65)
How to order manifold
How to order valves
VV5FS2
Plug-in dripproof manifold(Equivalent to IP65)
101WTBU 08 02
2 stations
15 stations
02
15
Stations
Common terminal box (U side mounting)Common terminal box (D side mounting)
01WTBU01WTBD
Attachment plug lead wire01W
Symbol
Symbol
SideBottom
PassageP, R1, R2 A, B
Common
Port sizeSymbol
0102
A, BP, R1, R2
M
12∗
How to Order
X5400VFS2 F51
NilR∗
Pilot type
123456
Symbol
123∗4∗56∗7∗9∗
∗ Option
Pilot valve manual override
Dripproof
Coil rated voltage
Nil None
ZWith light/surge
voltage suppressor
Option∗ Option
Manifold SpecificationsManifold
WiringApplicable value model
Porting specificationsRc
Stations
VV5FS2-01WTBUD VV5FS2-01W
Common terminal box Attachment plug lead wireVFS2�00-�F-X54
Common SUP, Common EXHSide: Rc 1/8, 1/4, Bottom: Rc 1/8 (Option)
Side: Rc 1/42 to 10 stations 2 to 15 stations
2(B), 4(A) port1(P), 3(R2), 5(R1) port
∗ Option
Rc Rc Mixed
1 4Rc 1 4
1 8
∗ For bottom ported, A/B port is available only with Rc .1 8
Internal pilot
External pilot
2 position single2 position double
3 position closed center3 position exhaust center3 position pressure center3 position double check
100 VAC, 50/60 Hz200 VAC, 50/60 Hz
110 to 120 VAC, 50/60 Hz220 VAC, 50/60 Hz
24 VDC12 VDC
240 VAC, 50/60 HzOther
∗ Option
Nil
B∗A∗
Non-locking push type (Flush)Non-locking push type (Extended)
Locking type (Tool required)
C∗ Locking type (Lever)
Q
CE-compliantNil —
CE-compliant
•••
••
•
Portingspecifications
Q
CE-compliantNil —
CE-compliant
1155
Series VFS20005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
1-02-16-VFS1000.qxd 09.11.2 1:31 PM Page 11
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Dripproof Manifold
∗ Terminal mounting stations are not included. Indicates Solenoid valve mounting stations.
Bottom ported: VV5FS2-01WTBD- 2-01
StationsL
L1
L2
1120131
2145156
3170181
4195206
5220231
6245256
7270281
8295306
9320331
10345356
FormulaL1 = 25 x n + 95L2 = 25 x n + 106
n: Stations
Bottom ported: VV5FS2-01W- 2-01
StationsL
L1
L2
17081
295
106
3120131
4145156
5170181
6195206
7220231
8245256
9270281
10 11 12 13 14 15295306
320331
345356
370381
395406
420431
FormulaL1 = 25n + 45L2 = 25n + 56
n: Stations
With common terminal box: VV5FS2-01WTB - 1- UD
1(P), 3(R2), 5(R1) port
1(P), 3(R2), 5(R1) port Insert plug with lead wireLead wire length L = 1000
x 25 Printed
Electrical entry
Electrical entry
2(B), 4(A) port
2(B), 4(A) port
External pilot port
External pilot port
Pilot EXH port
Pilot EXH port
Push type manual override
Push type manual override
Indicator light
Indicator light
Stations
Stations
15
8 (
3 p
ositio
n)
15
0.5
(D
ou
ble
)1
01
(S
ing
le)
15
8 (
3 p
ositio
n)
15
0.5
(D
ou
ble
)1
01
(S
ing
le)
Station Port size
With attachment plug lead wire: VV5FS2-01W- 1-Station Port size
Station
Station
U sideD side
U sideD side
1156
Series VFS2000
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1156
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
1157
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1157
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
� Correspondence of SI unit output numbers and solenoid valve coils
How to Order
VV5FS2 X46001S
Applicable modelsSI unit part no.
—EX123U-SUW1EX123U-SUH1EX123U-SSL1EX123U-SSL2EX124U-SDN1EX124U-SCS1EX124U-SCS2EX124U-SMJ1
DescriptionWithout SI unitNKE Corporation: Uni-wire System (16 outputs)NKE Corporation: Uni-wire H System (16 outputs)SUNX Corporation: S-LINK System (16 outputs)SUNX Corporation: S-LINK System (8 outputs)DevieNet (2 power supply systems)OMRON Corporation: CompoBus/S (16 outputs) (2 power supply systems)OMRON Corporation: CompoBus/S (8 outputs) (2 power supply systems) CC-Link (2 power supply systems)
Symbol0
F1HJ1J2QR1R2V
Nil RcNPT
NPTFG
Thread type
NTF
VFS2 00 5 F
<Wiring Example 1> Double wiring (Standard)
Plug-in typeSerial transmission kit
Stations3
18
3 stations
18 stations
Note 1) Max. 18 stations. Add 2 stations for serial unit mounting.
Note 2) Max. 18 stations for all-single wiring. (No. of valves: 16)For the standard double wiring, the maximum number of stations is 10. (No. of valves: 8)
Combination symbol
Symbol
SideBottom
SideBottom
SideBottom
SideBottom
Port specificationP R1, R2
Piping specificationA, B
Common
Individual
Common
Individual
Common
Common
Individual
Individual
12∗
3∗
4∗
5∗
6∗
7∗
8∗
∗ Option
Port sizeSymbol
0102M
A, BP, R1, R2
Rc 1/4
∗ For bottom ported: Rc 1/8 only
Rc 1/8Rc 1/4Mixed
Compatible with SI unit U sidemounating only
D side
Dou
ble
Dou
ble
Sin
gle
Sin
gle
Sin
gle
Dou
ble
Sin
gle
Sin
gle
SI u
nit
1
A B
2
A B
3
A B
4
A B
5
A B
6
A B
7
A B
8
A B
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
9 10
SI u
nit o
utpu
t no.
U side
<Wiring Example 2> Single/Double mixed wiring (Option)
∗ Mixed wiring is available as an option. Use the manifold specification sheet to specify this.
D side
Dou
ble
Dou
ble
Sin
gle
Sin
gle
Sin
gle
Dou
ble
Sin
gle
Dou
ble
Sin
gle
Sin
gle
SI u
nit
1
A B
2
A B
3
A
4
A
5
A
6
A B
7
A
8
A B
9
A
10
A
0 1 2 3 7 84 5 9 11 126
11 12
SI u
nit o
utpu
t no.
U side
10 11
24 VDC
Symbol123456
2 position single2 position double
3 position closed center3 position exhaust center3 position pressure center3 position double check
Nil Internal pilotExternal pilot
Pilot type
R
Nil Non-locking push type (Flush)Non-locking push type (Extended)
Locking type (Tool required)Locking type (Lever)
Pilot valve manual override
ABC
Nil NoneWith light/surge voltage suppressor
Option
Z
Nil NoneCoil rated voltage
How to Order Manifold
How to Order Valves
V 0 1 02
Refer to pages 1653 to 1655 for the details of the EX123/124 integrated type (for output) serial transmission system.
Made to OrderSerial Transmission Kit Manifold: EX123/124 Integrated Type (For Output) Serial Transmission System
1158
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1158
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Serial Transmission Kit Manifold: EX123/124 Integrated Type (For Output) Serial Transmission System
VV5FS2-01S Model - Stations Symbol - Port size -X460
Dimensions n: Stations (Max. 18 stations)Formula L1 = 28n + 47 L2 = 28n + 56
LL1
L2
n 3131140
4159168
5187196
6215224
7243252
8271280
9299308
10327336
11355364
12383392
13411420
14439448
15467476
16495504
17523532
18551560
Note) Actual number of manifold base stations: Add 2 SI unit mounting stations to the number of valve stations.
TM
MO
DE
LS
Q(SI No.EX124-SDN1)
01
SE
TT
ING
S
MO
D/N
ET
PW
R
B
A
B
A
B
A
B
A
B
A
L2
L1
5.4
R2.7
6844
79
119.
5
158
150.
5
10175
Manual overrideSI unit
SMCP
EA
EB
R2
PE
R1
38
30.5
16.5
26.5
13
8.5
14.522
.514
.5
40.5
63
119.
5
126.
5
2 x Rc 1/8
1(P), 5(R1), 3(R2) port6 x Rc 1/4
PE port
1 2 3 4 5 6 7 8 nStationsD side U side
SMC
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
SMCSMC SMC SMC
37.52842
123.
5
88.5
47
11.5
37.5
92
4(A), 2(B) port2n x Rc 1/8, 1/4
EX124�: 4 x G 1/2
Electrical entry
EX123�: 2 x G 1/2∗ Use a dripproof plug assembly
(AXT100-B04A) for the unused conduit port (G 1/2).
1159
Series VFS20005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:53 PM Page 1159
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
D side
U side
Not used for the 1st station on D side.
1 station2 stations 2 stations
1 station1 station2 stations2 stations
<5 stations (Odd number)>
<6 stations (Even number>
Example) U side D side123456n
• Manifold base is consisted of the junction of 2 and 3 station bases.
• For increasing the manifold bases, please order the manifold block assembly number of the principle number assembly !1 and !2.For plug-in type: The manifold base with terminal stand (integrated with a junction cover) is required with the !0 junction cover assembly.
∗ Manifold Base/Construction: Plug-in type with terminal block (01T1).
R1
R2
EB
P
EAPE
SMC
!3
wq
e
!2
!1u
yi
r!4
!0
o
!5
t
!6
Manifold Base Construction — Plug-in type, Non plug-in type
1160
Series VFS2000
1-02-16-VFS1000.qxd 10.2.15 11:05 AM Page 1
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Replacement PartsNo. Description Material Part no.1 Steel plateConnection fitting assembly AXT625-4-1A2 Connection fitting B Steel plate AXT625-53 Gasket A NBR AXT625-174 Gasket B NBR AXT625-16
6 O-ring NBR 18 x 15 x 1.57 O-ring NBR 10.5 x 7.5 x 1.58 O-ring NBR 8 x 5 x 1.5
Adapter plate Resin AXT625-6AXT625-28-13A(Terminal section with adapter plate and lead wire assembly)AXT625-28-1VVF2000-26-6AXT625-6AXT625-7AAXT625-28-3A
VVF2000-26-5A- AZ738-10A- AXT333-12AXT625-22
Plug EXP22S
9
10
15
Adapter plate assembly
Adapter plate
Junction cover assembly
Rubber plug
—
NBR
Resin
—
—
For 01For 01TFor 01T1For 01CFor 01F
For 01S�For 01
For 01TFor 01T1For 01CFor 01F
For 01S�For 01
For 01W
AXT625-28-7A- Stations
Stations
Stations
Replacement Parts: Sub AssemblyNo. Description Part no.
AXT625-01A- (-B) Note)
AXT625-20A- (-B) Note)
AXT625-10A- (-B) Note)
AXT625-2A
AXT625-2A-20
AXT625-2A-10
11
13End plate (U side)assembly
End plate (D side)assembly
Manifold blockassembly(for 1 station)
14
Applicable manifold basePlug-in type
With attachment plug lead wire
Plug-in typeWith terminal block
Non plug-in type
Plug-in typeWith attachment plug lead wire
Plug-in typeWith terminal block
Non plug-in type
Plug-in typeWith attachment plug lead wire
Plug-in typeWith terminal block
Non plug-in type
AXT625-3A
AXT625-3A-20
AXT625-3A-10
Component partsManifold block !1, Metal joint q, w, O-ring y, u, i, Junction cover !0, Adapter plate o, Pin housing, Guide, Insert plug lead wire
Manifold block !1, Metal joint q, w, O-ring y, u, i, Junction cover !0, Adapter plate assembly (with terminal) o, Pin housing, Guide
Manifold block !1, Metal joint q, w, O-ring y, u, i
End plate (U) !3, Metal joint q, w, Gasket A e, Guard !6
End plate (U) !3, Metal joint q, w, Gasket A e, Guard !6
End plate (U) !3, Metal joint q, w, Gasket A e
End plate (D) !4, Metal joint q, w, Gasket B r, Guard !6, Steel ball
End plate (D) !4, Metal joint q, w, Gasket B r, Guard !6, Steel ball
End plate (D) !4, Metal joint q, w, Gasket B r, Steel ball
Note) 1: A, B port size Rc 1/8, 2: A, B port size Rc 1/4, (-B): A, B port bottom ported
Gasket5 HNBR VVFS2000-32-1H
16 Guard Resin AXT625-28-4
AXT625-01A2- Note)
AXT625-20A2- Note)
AXT625-10A2- Note)
12Manifold blockassembly(for 2 stations)
Plug-in typeWith attachment plug lead wire
Plug-in typeWith terminal block
Non plug-in type
Manifold block !2, Metal joint q, w, Gasket t, Junction cover !0,Adapter plate o, Pin housing, Guide, Insert plug lead wire
Manifold block !2, Metal joint q, w, Gasket t, Junction cover !0,Adapter plate assembly (with terminal) o, Pin housing, Guide
Manifold block !1, Metal joint q, w, Gasket t
01T (1)01S�For
0101T (1)For
12
12
12
12
12
12
1160-1
Series VFS20005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
1-02-16-VFS1000.qxd 10.2.15 11:05 AM Page 2
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Light Compact Type Sub-plate/C: 2.8 dm3/(s·bar)
TypeCompact typeStandard type
25.531
0.130.2
Sub-plateC: 2.2 dm3/(s·bar)
Compact type Standard type
Bottom ported
Sub-plate — Compact: Plug-in, Grommet (With attachment plug lead wire)
( ): Port size P02
Port Size
Bottom Ported Size
Sub-plate — Compact: Non plug-in
Precautions Please pay attention to piping port location of sub-plate.
( ): Port size S02
PortPort size
S01S02
P, A, BRcRc
1 81 4
EA, EBRcRc
1 81 8
PortPort size
BS02P, A, B
Rc 1 41 8
EA, EBRc 1 8
VFS2�10-��-(B)
Sub-plate assembly part no.: VFS2000-CP-(B) (01: Rc , 02: Rc )
L dimension(mm)
Mass(kg)
VFS2�00-�F-(B) P01P02
S01S02
1 8 1 40102
Sub-plate assembly part no.: VFS2000-CS-(B) (01: Rc , 02: Rc )1 8 1 40102
PortPort size
P01P02
P, A, BRc Rc
1 81 4
EA, EBRc Rc
1 81 8
Port Size
Bottom Ported SizePortPort size
BP02P, A, B
Rc ,1 41 8
EA, EBRc 1 8
Solenoid
Lead wire color Red Black Brown WhiteA side B side
• There is no polarity.
C: 2.8 dm3/(s·bar)
VFS2��0-��- : Compact typeP01/02S01/02 VFS2��0-��- : Standard type01
02
Electrical Connection
L dimensionL dimension
1 (Center)Pilot EXH port
1 (Center)
Pilot EXH port
5 x bottom ported size (Refer to the right.)
5 x bottom ported size (Refer to the right.)
5 x bottom ported size(Refer to the below right.)
2 x ø4.5 mounting hole
2 x ø4.5 mounting hole
Lead wire
≅300
5 x bottom ported size(Refer to the below right.)
Electrical entry
Bottom ported
Compact type, plug-in type grommet sub-plate (With attachment plug lead wire)• The attachment plug lead wire is attached to the
manifold block and lead wire is plugged in with valve side as shown in the following list. Please connect with corresponding power side.
1161
Series VFS20005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:54 PM Page 1161
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model
Standard Specifications
OptionJIS Symbol
Type of actuation
Model
Plug-in Non plug-in
VFS3100
VFS3200
VFS3300
VFS3400
VFS3500
1 43 81 43 81 43 81 43 81 43 8
1200
1500
600
600
600
VFS3600
VFS3110 6.07.36.07.35.86.86.17.46.07.24.04.0
0.150.230.150.230.210.220.230.200.220.19——
1.41.81.41.81.41.71.41.81.51.8——
5.86.85.86.85.46.35.05.65.87.13.53.7
0.120.120.120.120.140.120.140.180.160.18——
1.31.61.31.61.21.51.21.31.31.8——
VFS3210
VFS3310
VFS3410
VFS3510
VFS36101 43 8
600
0.31
0.41
0.43
0.43
0.43
0.91
C[dm3/(s·bar)]
C[dm3/(s·bar)]b Cv b Cv
1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) Flow characteristics
Pilot typeManualoverride
Main valvePilot valve
Coil rated voltage
Porting specificationsOption
2 positionSingle
Double
3 positionClosed center
Exhaust center
Pressure center
Double check
Compact yet provides a large flow capacity3/8: C: 5.8 dm3/(s·bar)
Low power consumption: 1.8 W DC
Easy maintenance2 types of sub-plates:
Plug-in and non plug-in
Plug-in type
Non plug-in type
2 po
sitio
n3
posi
tion
Single
Double
Closedcenter
Pressure center
Exhaust center
PortsizeRc
20 or less
15 or less
40 or less
40 or less
40 or less
Note 1) Based on JIS B 8375 (once per 30 days) for the minimum operating frequency. Note 2) Based on JIS B 8375-1981 (the value at supply press. 0.5 MPa).Note 3) The figures in the above list are for without sub-plate. In the case of with plug-in sub-plate and with non plug-in sub-plate, add 0.30 kg and 0.27 kg respectively. Note 4) “Note 1)” and “Note 2)” are with controlled clean air.
Doublecheck 50 or less
FluidMaximum operating pressureMinimum operating pressureProof pressureAmbient and fluid temperatureLubricationPilot valve manual overrideShock/Vibration resistance EnclosureCoil rated voltageAllowable voltage fluctuationCoil insulation typeApparent power(Power consumption)
Power consumption DC
InrushHolding
Electrical entry
Val
ve s
pec
ific
atio
ns
Elec
tric
ity s
peci
ficat
ions
Air/Inert gas
1.5 MPa–10 to 60°C (1)
Non-lube (2)
Non-locking push type (Flush)150/50 m/s2 (3)
Type E: Dustproof (Level 0), Type F: Dripproof (Level 2), Type D: Splashproof (Level 4) (4)
100, 200 VAC, 50/60 Hz; 24 VDC–15 to +10% of rated voltage
Class B or equivalent (130°C) (5)
5.6 VA/50 Hz, 5.0 VA/60 Hz3.4 VA (2.1 W)/50 Hz, 2.3 VA (1.5 W)/60 Hz
1.8 W (2.04 W: With light/surge voltage suppressor)Plug-in type
Non plug-in type
1.0 MPa0.1 MPa
Note 1) Use dry air at low temperatures.Note 2) Use turbine oil Class 1 (ISO VG32), if lubricated.Note 3) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial di-
rection and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period)
Note 4) Based on JIS C 0920. Note 5) Based on JIS C 4003.
AC
Conduit terminalDIN terminal, Grommet terminal
External pilot Note)
Direct manual override typeNon-locking push type (Extended), Locking type (Tool required), Locking type (Lever)
110 to 120, 220, 240 VAC (50/60 Hz)12, 100 VDCBottom ported
With light/surge voltage suppressor
Note) Operating pressure: 0 to 1.0 MPa Pilot pressure: 0.1 to 1.0 MPa
Max. operating
cycle(cpm)
Responsetime(ms)
(Details → P. 1222-2)
Mass(kg)
(1)(2)
(3)
1162
5 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
Series VFS3000
VFS.qxd 10.11.25 9:49 AM Page 7
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
1 02FPlug-in VFS3 1
D
Q
CE-compliantNil —
CE-compliant
Non plug-in VFS3
Symbol
1
2 position single
2
2 position double
3
3 position closed center
4
3 position exhaust center
5
3 position pressure center
6
3 position double check
O: Plug-in typesub-plate
1: Non plug-in type sub-plate
Body type
Pilot valveManual override
Portingspecifications
Port sizeNil0203
Thread typeNilN∗ NPT
Rc
T∗ NPTFF∗ G
∗ Option
Pilot typeNilR∗
Internal pilotExternal pilot
∗ Option
Body Option01∗
StandardDirect manual override
∗ Option
Coil rated voltage123∗4∗56∗7∗9∗
∗ Option
02
0 0
2
Body type
OptionNilZ
NoneWith light/surge voltage suppressor
F: Plug-in typeconduit terminal
Electrical entry
E: Grommet terminal D: DIN terminal
Electrical entry
2 1 1
Rated voltage
∗ Option
Manual override Coil rated voltage
SF4 F1 30
How to Order Pilot Valve Assembly
How to Order
NilB∗
Side portedBottom ported
∗ Option
Without sub-plateRcRc
1 4
1 4
3 8
100 VAC, 50/60 Hz200 VAC, 50/60 Hz
110 to 120 VAC, 50/60 Hz220 VAC, 50/60 Hz
24 VDC12 VDC
240 VAC, 50/60 HzOther
Nil: Non-locking push type(Flush)
A∗: Non-locking push type(Extended)
B∗: Locking type (Tool required)
C∗: Locking type(Lever)
1 100 VAC, 50/60 Hz
Symbol Symbol Manual override
2 200 VAC, 50/60 Hz3∗ 110 to 120 VAC, 50/60 Hz4∗ 220 VAC, 50/60 Hz5 24 VDC6∗ 12 VDC7∗ 240 VAC, 50/60 Hz9∗ Other
Nil
B∗
A∗
Non-locking push type(Flush)
Non-locking push type(Extended)
Locking type (Tool required)
C∗ Locking type (Lever)
∗ For bottom ported, Rcis only available.
∗ Reverse pressure: Can be used by external pilot specifications.
∗ Refer to page 1224 for voltage conversion.
∗ Option
1163
Series VFS30005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
1-02-16-VFS1000.qxd 09.11.2 1:31 PM Page 13
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
System
A
800700600500400300200100 0
B
800
900
900
1000
1000
700600500400300200100 0
Bore size
ø40 ø50 ø63 ø80 ø100 ø125 ø140 ø160 ø180 ø200
System Components
Double Check Spacer/Specifications
Specifications Check Valve Operation
Caution
Double check spacer
Cylinder Speed Chart
Can hold an intermediate cylinder position for an extended timeIf the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools. • In the case of 3 position double check
valve (VFS36�0), check the leakage from piping and fittings in between valve and cylinder by means of synthetic detergent solutions, and ensure that there is no such leakage found there. Also check the leakage from cylinder seal and piston seal. If there is any leakage, sometimes the cylinder, when valve is de-energized, can move without stopping at intermediate position.
• Be aware that if the exhaust side is restricted excessively, the intermediate stopping accuracy will decrease and will lead to improper intermediate stops.
• The combination of VFS31 0, VFS32 0 and double check spacer can be used as prevention for falling at the stroke end but cannot hold the intermediate position of the cylinder.
SeriesVFS3000
Rc
System
A
B
Solenoid valveSpeed
controller
SeriesVFS3000
Rc 1 4
3 8
AS4000-02(S = 24 mm2)
AS420-03(S = 73 mm2)
Silencer
AN200-02(S = 35 mm2)
AN300-03(S = 60 mm2)
SGP (Steel pipe)Port size x Length
6A x 1 m
10A x 1 m
Plug-in type
Non plug-in type
Double checkspacer part no.
Applicablevalve model
Plug-in typeVVFS3000-22A-1
VFS3400-�F
Non plug-in typeVVFS3000-22A-2
VFS3410-�DVFS3410-�E
Averagespeed(mm/s)
Series MB, CA2Pressure 0.5 MPaLoad factor 50%Stroke 500 mm
Series CS1/CS2Pressure 0.5 MPaLoad factor 50%Cylinder stroke 1000 mm
Perpendicular,upward actuationHorizontalactuation
Use as a guide for selection.Please confirm the actual conditions with SMC Sizing Program.
∗ It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open.
∗ The average velocity of the cylinder is the value that the stroke is divided by the total stroke time.
∗ Load factor: ((Load weight x 9.8)/Theoretical force) x 100%
01
01
Check valve
Piston SUP side pressure (P1)
Operating range
Cylinder side pressure P2 (MPa)
Cylinder side pressure (P2)
SU
P s
ide
pres
sure
P1
(MP
a)
1164
Series VFS3000
P1111-P1228-E.qxd 08.9.2 2:54 PM Page 1164
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Construction
Sub-plate Assembly Part No.
2 position single
3 position closed center/exhaust center/pressure center
2 position double
Part no. for mounting bolt and gasketBG-VFS3000
∗ Mounting bolt and gasket are not included.
Sub-plate Assembly (For External Pilot) Part No.
Plug-inNon plug-in
Component PartsNo.
23
1Aluminum die-casted
Stainless steel
MaterialAluminum die-casted
Note
4 Resin
Platinum silver—
Platinum silver
Black5 Resin Black6 Resin —7 Resin —8 Resin —9 Stainless steel —10 NBR —11 Steel —12 — —13 — —
∗ Refer to “How to Order Pilot Valve Assembly” on page 1163.
Closed center
Exhaust center
Pressure center
Description
Sub-plateBody
Spool/SleeveAdapter plateEnd platePistonJunction coverLight coverReturn springGasket
Pilot valve assembly
Hexagon socket head screwDetent assembly
Plug-inNon plug-in
VFS3000-P- VFS3000-S-
02030203
VFS3000-P-R VFS3000-S-R
02030203
1165
Series VFS30005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
265-VFS.qxd 10.5.7 10:40 AM Page 1
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Plug-in — 2 Position single/3 Position closed center/Exhaust center/Pressure center/Double check
2 position single: VFS3100-�F
2 position double: VFS3200-�F3 position closed center: VFS3300-�F3 position exhaust center: VFS3400-�F3 position pressure center: VFS3500-�F
3 position double check: VFS3600-�F
Bottom ported
2 x ø5.6 mounting hole
2 x ø5.6 mounting hole
2 x ø5.6mounting hole
Pilot valve manual override
G 1/2 electrical entry
170.5 (3 position: 175)
86.5 (3 position: 96.5)
Pilot valvemanual override
Pilot valvemanualoverride
With
dire
ct m
anua
l ove
rrid
e
With
dire
ct m
anua
l ove
rrid
eLight window
With
dire
ct m
anua
l ove
rride
At FZ
Light windowAt FZ
Light windowAt FZ
Rc 1/8 external pilot port
(Only for external pilot) 2(B), 4(A) port
G 1/2 electrical entryG 1/2 electrical entry
(PE port)
2 x ø5.6mounting hole
1 4( ): Rc
1 4( ): Rc 1 4( ): Rc
1166
Series VFS3000
P1111-P1228-E.qxd 08.9.2 2:54 PM Page 1166
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Non Plug-in — 2 Position single/Double/3 Position closed center/Exhaust center/Pressure center/Double check
2 position single: VFS3110-�E, VFS3110-�D
2 position double: VFS3210-�E, VFS3210-�D3 position closed center: VFS3310-�E, VFS3310-�D3 position exhaust center: VFS3410-�E, VFS3410-�D3 position pressure center: VFS3510-�E, VFS3510-�D
3 position double check: VFS3610-�E, VFS3610-�D
Bottom ported
2 x ø5.6 mounting hole
2 x ø5.6 mounting hole
Light window at DZ, EZ
Applicable heavy-duty cord O.D.ø8 to ø10
Pilot valvemanual override
Applicable heavy-duty cord O.D.ø8 to ø10
Pilot valvemanual override
165 (3 position: 175)
2 x ø5.6 mounting hole
Rc 1/8 external pilot port(Only for external pilot)
2(B), 4(A) port
Light windowAt DZ, EZ
Light windowAt DZ, EZ
Cable ø8 to ø10
Pilot valve manual override
With
dire
ct m
anua
l ove
rrid
e
With
dire
ct m
anua
l ove
rrid
e
With
dire
ct m
anua
l ove
rrid
e
2 x ø5.6 mounting hole
1 4( ): Rc
1 4( ): Rc 1 4( ): Rc
(PE port)
1167
Series VFS30005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:54 PM Page 1167
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Q
CE-compliantNil —
CE-compliant
Port sizeSymbol
0203
A, BP, EA, EB
M
NilN∗
RcNPT
NPTFG
T∗F∗
∗ Option
Thread typeQ
CE-compliantNil —
CE-compliant
RcRc Rc Mixed
3 81 2
1 4
∗ Option
Symbol
Symbol
1 Side2 Bottom∗
Passage Portingspecifications
(A, B)EA, EBP
CommonCommon
Plug-in Type: With Terminal Block
Plug-in Type: With Multi-connector (Wiring specifications: Refer to page 1227.)
Plug-in Type: With D-sub Connector
Non Plug-in Type: Grommet Terminal, DIN Terminal
01TVV5FS3
Plug-in typewith terminal block
Port sizeSymbol
0203
A, BP, EA, EB
M
106 02Series VFS3000
Manifold
2 stations
8 stations
02
08∗
Stations
NilN∗
RcNPT
NPTFG
T∗F∗
∗ Option
Thread type
NilN∗
RcNPT
NPTFG
T∗F∗
∗ Option
Thread type
D01CVV5FS3
Plug-in typewith multi-connector
205 02Series VFS3000
Manifold
∗ Max. 8 stations
D01FVV5FS3
Plug-in typewith D-sub connector
106 02Series VFS3000
Manifold
10VV5FS3
Non plug-in type
205 02Series VFS3000
Manifold
• Since lead wires of solenoid valve are connected with the terminals on upper surface of terminal block, corresponding lead wires from power source can be wired at the bottom of terminal block.
• Master connection of power and solenoid valves.
• Quick wiring permits easier installation.
• Wide range of interchangeability(MIL Spec D-sub connector termi-nal 25 pcs attached.)
• Quick wiring permits easier installation.
• Wiring for every valve.
RcRc Rc Mixed
3 81 2
1 4
Port sizeSymbol
0203
A, BP, EA, EB
M
RcRc Rc Mixed
3 81 2
1 4
∗ Option
Symbol
Q
CE-compliantNil —
CE-compliant
Symbol
1 Side2 Bottom∗
Passage Portingspecifications
(A, B)EA, EBP
CommonCommon
∗ Option
Symbol
Symbol
1 Side2 Bottom∗
Passage Portingspecifications
(A, B)EA, EBP
CommonCommon
Q
CE-compliantNil —
CE-compliant
D side mountingU side mounting
DU
Connector mountingdirection
(Wiring specifications: Refer to page 1227.)
··· ···2 stations
16 stations
02
16
Stations
··· ···
2 stations
16 stations
02
16
Stations
··· ···
2 stations
8 stations
02
08∗
Stations
NilN∗
RcNPT
NPTFG
T∗F∗
∗ Option
Thread type
∗ Max. 8 stations
Port sizeSymbol
0203
A, BP, EA, EB
M
RcRc Rc Mixed
3 81 2
1 4
∗ Option
Symbol
Symbol
1 Side2 Bottom∗
Passage Portingspecifications
(A, B)EA, EBP
CommonCommon
D side mountingU side mounting
DU
Connector mountingdirection
··· ···
U side
D side
U side
D side
Terminal block
Plug assembly (Option)Refer to page 1227.
Plug assembly (Option)Refer to page 1227.
Multi-connector
D-sub connector
DIN terminal
Grommet terminal
1168
Series VFS3000Manifold Specifications
1-02-16-VFS1000.qxd 09.11.2 1:31 PM Page 14
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Flow Characteristics at the Number of Manifold Stations (Operated individually)
How to Order Manifold Assembly
∗ Port size: Rc 3/8
Passage/Stations Station 1 Station 5 Station 106.00.201.47.0
0.201.8
6.00.201.47.0
0.201.8
6.00.201.47.00.201.8
Model
VV5FS3
Manifold SpecificationsPlease indicate manifold base type, corresponding valve, and option parts.
<Example>• Plug-in type with terminal block: 6 stations
(Manifold base) VV5FS3-01T-061-02 ······1(2 position single) VFS3100-5FZ ············3(2 position double) VFS3200-5FZ ···········2(Blanking plate) VVFS3000-10A ·············1
<Example>• Non plug-in type: 6 stations
(Manifold base) VV5FS3-10-061-03 ········1(2 position single) VFS3110-5D ···············5(3 position exhaust center) VFS3410-5D ·····1(Individual EXH spacer) VVFS3000-R-03-2 ···1
,
Base model
Plug-in typeVV5FS3-01
Non plug-in typeVV5FS3-10
Wiring
• With terminal block• With multi-connector• With D-sub connector
• DIN terminal• Grommet terminal
Portingspecifications
A, B port
Side/Bottom
P, EA, EB
1 21 4 3 8
Port size RcA, B
Stations
2 to 10
Applicablevalve model
VFS3�00-�F
VFS3�10-�DVFS3�10-�E
(1) (2)
Note 1) Appropriate silencer for EA, EB port: “AN403-04” (O.D. ø27).Note 2) With multi-connector, or with D-sub connector: 8 stations max.
4/2 5/3(A/B R1/R2)
C [dm3/(s·bar)]
bCv
1 4/2(P A/B)
bC [dm3/(s·bar)]
Cv
1169
Series VFS30005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:54 PM Page 1169
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Manifold Option Parts AssemblyIndividual SUP spacerAn individual SUP spacer set on manifold block can form SUP port for every valve.
Individual EXH spacerAn individual EXH spacer set on manifold block can form EXH port for every valve. (common EXH type)
∗ SUP block plateWhen supplying manifold with more than two different pressures, high and low, insert a block plate in between stations subjected to different pressures.
∗ EXH block plateWhen valve exhaust affects the other stations on the circuit or when the reverse pressure valve is used to standard manifold valve, insert EXH block plate between stations to separate valve exhaust.
Throttle valve spacerNeedle valve set on the manifold block can control cylinder speed by throttling exhaust.
Double check spacerIf the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools.
Blanking plateIt is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc.
Interface regulatorInterface regulator set on manifold block can regulate the pressure to each valve. (Refer to page 1225 for “Flow Characteristics”.)
With control unitPlug-in type/Non Plug-in type• Filter, regulation valve, pressure switch
and air release valve are all combined to form one unit.
• Piping processes are eliminated.
For details, refer to page 1173.
Made to OrderSerial transmission kit manifold Plug-in type• Solenoid valve wiring process reduced
considerably.
For details, refer to page 1175.
For details, refer to page 1178.
With exhaust cleanerPlug-in type/Non Plug-in type • Valve exhaust noise dampening: 35 dB
or more.• Oil mist collection: Rate of collection
99.9% or more.• Piping process reduced.
Manifold Option
Body type Plug-in typeVVFS3000-P-03-1
Non plug-in typeVVFS3000-P-03-2Part no.
Body type Plug-in typeVVFS3000-20A-1
Non plug-in typeVVFS3000-20A-2Part no.
Body type Plug-in typeVVFS3000-22A-1
Non plug-in typeVVFS3000-22A-2Part no.
Body type Plug-in typeVVFS3000-R-03-1
Non plug-in typeVVFS3000-R-03-2Part no.
Body type Plug-in typeAXT636-1A
Non plug-in typePart no.
Body type Plug-in typeAXT636-1A
Non plug-in typePart no.
Body type Plug-in typeVVFS3000-10A
Non plug-in typePart no.
Body type Plug-in typeARBF3050-00-P-1
Non plug-in typeARBF3050-00-P-2P port regulation
ARBF3050-00-A-1 ARBF3050-00-A-2A port regulationARBF3050-00-B-1 ARBF3050-00-B-2B port regulation
1170
Series VFS3000
P1111-P1228-E.qxd 08.9.2 2:54 PM Page 1170
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Formula for manifold weight M = 0.405n + 0.665 (kg) n: Station
Manifold — Plug-in type, Non plug-in type
Non plug-in type: VV5FS3-10- 1-
Bottom ported:VV5FS3-01T- Station 2- Port size
Formula for manifold weight M = 0.309n + 0.532 (kg) Stations
L
L1
L2
2129141
3162174
4195207
5228240
6261273
7294306
8327339
9360372
10393405
FormulaL1 = 33 x n + 63L2 = 33 x n + 75
n: Stations
Plug-in type (With terminal block): VV5FS3-01T- 1-
Bottom ported:VV5FS3-10- Station 1- Port size
Station Port size
Station Port size
Stations
Stations
(Pilot EXH port: PE)
Electrical entry
(External pilot port)
Light window
Light window
Applicable cabtire cable O.D.ø8 to ø10
Pilot valve manual override
Pilot valve manual override
U side
D side
U side
D side
(External pilot port)(Pilot EXH port: PE)
1171
Series VFS30005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:54 PM Page 1171
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Formula for manifold weight M = 0.41n + 0.753 (kg) n: Station ∗ Wiring specifications: Refer to page 1227.
Formula for manifold weight M = 0.41n + 0.677 (kg) n: Station∗ Wiring specifications: Refer to page 1227.
Manifold — Plug-in type with multi-connector/D-sub connector
Plug-in type with D-sub connector: VV5FS3-01FD- Station 1- Port size , VV5FS3-01FU- Station 1- Port size
CDCU
StationsL
L1
L2
2129141
3162174
4195207
5228240
6261273
7294306
8327339
FormulaL1 = 33 x n + 63L2 = 33 x n + 75
n: Stations
Plug-in type with multi-connector: VV5FS3-01CD- Station 1- Port size , VV5FS3-01CU- Station 1- Port size
Bottom ported: VV5FS3-01 - Station 2- Port size
Bottom ported:VV5FS3-01 - Station 2- Port sizeFD
FU
(Pilot EXH port: PE)
Plug assembly VVZS3000-21A-�(Option: Refer to page 1227.)
(External pilot port)
(Pilot EXH port: PE)(External pilot port)
Light window
Light window
Plug assembly VVFS2000-30A-�(Option: Refer to page 1227.)
Pilot valve manual override
Pilot valve manual override
Stations
Stations
U side
D side
U side
D side
1172
Series VFS3000
P1111-P1228-E.qxd 08.9.2 2:54 PM Page 1172
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Manifold Specifications
Manifold with Exhaust Cleaner
Plug-in type
Non plug-in type
CautionWhen using an exhaust cleaner, mount it downwards.
∗ For details about exhaust cleaners, refer to Best Pneumatic Vol. 6.
Manifold
Wiring
Applicable valve model
Porting specificationsRc
Stations
Plug-in type: VV5FS3-01� Non plug-in type: VV5FS3-10
Applicable exhaust cleaners
Note 1) With multi-connector, or with D-sub connector: 8 stations max. Note 2) Exhaust cleaner “AMC610-10” is not attached.
10610 03 CDSeries VFS3000
Manifold
VV5FS3
Exhaust cleanermounting direction
NilN∗
RcNPT
NPTFG
T∗F∗
∗ Option
Thread type
Port size
How to Order
• Serves to protect workingenvironment.
• Valve exhaust noise dampening: 35 dB or more.
• Collection rate of drainage and oil mist: 99.9% or more.
• Piping work is reduced.
With terminal blocksWith multi-connectorWith D-sub connector
DIN terminal Grommet terminal
VFS3�00-�F VFS3�10-�D, VFS3�10-�ECommon SUP, Common EXH
P: 1/2, EXH: 1 2 to 10 (1)
AMC610-10 (Connecting port size R 1) (2)
2(B), 4(A) port 1/4, 3/81(P), 3(R2), 5(R1) port
Symbol
Symbol
1 Side
2 Bottom∗
Passage
R1, R2P
CommonCommon
∗ Option
Base type/Electricalentry
Plug-in typewith terminal block
Plug-in typewith multi-connector
01T
01C
Plug-in typewith D-sub connector
Non plug-in type
01F
10
Symbol
CDCU
D sideU side
D side mounting
U side mounting
Exhaust cleanermounting direction
Symbol Applicable base
DNil
U01C, 01F
01T, 10With connector
D side mountingNone
U side mounting
Connector mounting direction
2 stations
10 stations
02
10
Stations
Base type 01T, 10: 2-10 stationsBase type 01C, 01F: 2-8 stations
<Example> • Plug-in type with terminal block (6 stations)
(Manifold base)(2 position single)(2 position double)(Blanking plate)(Exhaust cleaner)
• Non plug-in type (6 stations)
13211
VV5FS3-01T-061-03-CDVFS3100-5FZVFS3200-5FZVVFS3000-10AAMC610-10
(Manifold base)(2 position single)(2 position double)(Blanking plate)(Exhaust cleaner)
13211
VV5FS3-10-061-03-CUVFS3110-5EVFS3210-5EVVFS3000-10AAMC610-10
Symbol0203
A, BP
RcRc Rc
M Mixed
3 81 2
1 4
··· ···
Portingspecifications
(A, B)
U side
D side
Exhaust cleaner AMC610-10(Option)
Exhaust cleaner AMC610-10(Option)
How to Order Manifold Assembly [Example]Add the valve and option part numbers in order starting from the first station on the D side.
∗ ∗ ∗
∗ ∗ ∗
The asterisk denotes the symbol for assembly. Prefix it to the part numbers of the solenoid valve.
Q
CE-compliantNil —
CE-compliant
1173
Series VFS30005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
1-02-16-VFS1000.qxd 09.11.2 1:31 PM Page 15
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
≅≅
Manifold with Exhaust — Plug-in type, Non plug-in type
StationsL
L1
L2
2129141
3162174
4195207
5228240
6261273
7294306
8327339
9360372
10393405
FormulaL1 = 33 x n + 63L2 = 33 x n + 75
n: Stations
D side mounting
U side mounting
D side mounting
U side mounting
Plug-in type: VV5FS3-01T- Station 1- Port size - CDCU
Non plug-in type: VV5FS3-10- Station 1- Port size -CDCU
Pilot valvemanual override
Stations
Stations
Light
Light
Pilot valve manual override
(External pilot port: X12)(Pilot EXH port: PE)
Electrical entry
Exhaust cleaner(Option)
Exhaust cleaner(Option)
D side
U sideD side
U side
D side
U side
D side
U side
Pilot valve manual override
(External pilot port: X12)(Pilot EXH port: PE)
1174
Series VFS3000
P1111-P1228-E.qxd 08.9.2 2:54 PM Page 1174
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Manifold with Control Unit
Plug-in type
Non plug-in type
How to Order
VV5FS3 10 08 1 02 APSeries VFS3000
Manifold Air release valve coil ratingNil None (F, G type only)
100 VAC, 50/60 Hz24 VDCOther
159
01T01C01F10
Thread type
Base type/Electrical entry
Stations
NilN∗
RcNPT
NPTFG
T∗
F∗
∗ Option
How to Order Manifold Assembly [Example]Add the valve and option part numbers in order starting from the first station on the D side.
Manifold Specifications
Control Unit Specifications Control Unit/Option
Manifold
Wiring
Applicable valve model
Porting specificationsRc
Stations
Plug-in type: VV5FS3-01� Non plug-in type: VV5FS3-10With terminal block
With multi-connectorWith D-sub connector
DIN terminal Grommet terminal
VFS3�00-�F VFS3�10-�D, VFS3�10-�ECommon SUP, Common EXH
2 to 10 ∗
∗ With multi-connector, or with D-sub connector: 8 stations max.
2(B), 4(A) port 1/4, 3/81/21(P), 3(R2), 5(R1) port
Air filter (With auto-drain/With manual drain)Filtration degreeRegulatorSet pressure (Outlet pressure)Pressure switch(1)
Set pressure range: OFFDifferentialContact
Max. switch capacity
Max. operating current
Air release valve (Single only)Operating pressure range
5 µm
0.05 to 0.85 MPa
0.1 to 0.6 MPa
0.1 to 1.0 MPa
0.08 MPa or less1a
Indicator light LED (RED)2 VA AC, 2 W DC
24 VAC/DC or less: 50 mA100 VAC/DC: 20 mA
Air release
valvespacer
Pressure
switch
Blankingplate
Filterelement
<Plug-in type>VVFS3000-24A-1R (D side mounting)<Non plug-in type>VVFS3000-24A-2R (D side mounting)
IS1000P-2-1Filter regulatorPressure switchRelease valve
MP2-3MP3-2
VVFS3000-24A-10INA-13-854-12-5B
Note 1) Voltage: 24 VDC to 100 VACInner voltage drop: 4 V
Note 2) Combination of valve VFS31�� (single) and a release valve spacer can be used an air release valve.
Note 3) The non plug-in type cannot be mounted afterwards.
Air filter with auto-drainControl equipment
Symbol
Air filter with manual drainRegulator
Air release valvePressure switchBlanking plate (Air release valve)Blanking plate (Filter, Regulator)Blanking plate (Pressure switch)
Number of manifold blocksrequired for mounting (stations) 2 2 2 2 2 2 2 1
Nil A AP M MP F G C E
Control unit type
Plug-in type with terminal blockPlug-in type with multi-connectorPlug-in type with D-sub connector
Non plug-in type
Symbol Applicable base
DNil
U01C, 01F
01T, 10With connector
D side mountingNone
U side mounting
Connector mounting direction
Symbol
Port size
2 stations
10 stations
02
10Base type 01T, 10:2 to 10 stationsBase type 01C, 01F:2 to 8 stations
Symbol
0203
A, BP, EA, EB
RcRcRc
M Mixed
3 81 2
1 4
Symbol
1 Side2 Bottom∗
Passage
EA, EBP
CommonCommon
(Manifold base)(2 position single)(2 position double)
• Non plug-in type — In order to mount control unit, it requires 2 stations.(Manifold base)(2 position single)
142
14
VV5FS3-01T-081-03-AP5VFS3100-5FZVFS3200-5FZ
VV5FS3-10-061-03-AVFS3110-5D
• Control unit (Filter, Regulator, Pressure switch, Air release valve) are all standardized to the one unit, and can be mounted on the manifold base without any attachments.
• Piping processes are eliminated.
··· ···
∗ Option
Portingspecifications
(A, B)
U side
D side
CautionWhen using an air filter with auto-drain or manual drain, mount the filter vertically.
<Example> • Plug-in type with terminal block — In order to mount control unit, it requires 2 stations.
∗ ∗
∗
The asterisk denotes the symbol for assembly. Prefix it to the part numbers of the solenoid valve.
(2)
(3)
Q
CE-compliantNil —
CE-compliant
1175
Series VFS20005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
1-02-16-VFS1000.qxd 09.11.2 1:31 PM Page 16
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
≅
≅
≅
≅
Manifold with Control unit — Plug-in type, Non plug-in type
Example for manifold
StationsL
L1
L2
L3 (MP)L3 (AP)
3162174
4 5 6 7 8 9 10 FormulaL1 = 33 x n + 63L2 = 33 x n + 75
363384.5
195207396417.5
228240429450.5
261273462483.5
294306495516.5
327339528549.5
360372561582.5
393405594615.5
L3 = 33 x n + 264L3 = 33 x n + 285.5
Non plug-in type: VV5FS3-10- 1- -AP
Example for manifold
Station Port size Voltage for release valve
Plug-in type: VV5FS3-01T- 1- -APStation Port size Voltage for release valve
(Po port)
(External pilot port: X12)
Rc 1/2 (Po port)
(External pilot port: X12)
(Pilot EXH port: PE)
Electrical entry
Pilot valve manual override
Pilot valve manual override
Stations
Stations
Light
Light
Pressure switchPressure switch
Pressure switch
Pressure switchAir release valve
Air release valveAir release valve
Air
rele
ase
valv
e
(195
: -M
P)
(195
: -M
P)
Individual EXH spacer
Individual SUP spacer
Double check spacer
Outlet for check
Air
filte
rre
gula
tor
Control unit
Outlet for check
Air
filte
rre
gula
tor
Control unit
U side
U side
D side
D side
(Pilot EXH port: PE)
Pressure switch
Air
rele
ase
valv
e
Individual EXH spacer
Double check spacer
Individual SUP spacer
1176
Series VFS3000
P1111-P1228-E.qxd 08.9.2 2:54 PM Page 1176
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
1177
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:54 PM Page 1177
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
VV5FS3 X27901S
Applicable modelsSI unit part no.
—EX123U-SUW1EX123U-SUH1EX123U-SSL1EX123U-SSL2EX124U-SDN1EX124U-SCS1EX124U-SCS2EX124U-SMJ1
DescriptionWithout SI unitNKE Corporation: Uni-wire System (16 outputs)NKE Corporation: Uni-wire H System (16 outputs)SUNX Corporation: S-LINK System (16 outputs)SUNX Corporation: S-LINK System (8 outputs)DevieNet (2 power supply systems)OMRON Corporation: CompoBus/S (16 outputs) (2 power supply systems)OMRON Corporation: CompoBus/S (8 outputs) (2 power supply systems) CC-Link (2 power supply systems)
Symbol0
F1HJ1J2QR1R2V
Nil RcNPT
NPTFG
Thread type
NTF
Plug-in typeSerial transmission kit
Combination symbol
Symbol
SideBottom
Port specificationP R1, R2
Piping specificationA, B
CommonCommon12∗
∗ Option
Port sizeSymbol
0203M
A, BP, R1, R2
Rc 1/2
∗ For bottom ported: Rc 1/8 only
Rc 1/4Rc 3/8Mixed
� Correspondence of SI unit output numbers and solenoid valve coils<Wiring Example 1> Double wiring (Standard)
D side
Dou
ble
Dou
ble
Sin
gle
Sin
gle
Sin
gle
Dou
ble
Sin
gle
Sin
gle
SI u
nit
1
A B
2
A B
3
A B
4
A B
5
A B
6
A B
7
A B
8
A B
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
9
SI u
nit o
utpu
t no.
U side
VFS3 00 5 F
24 VDC
Symbol123456
2 position single2 position double
3 position closed center3 position exhaust center3 position pressure center3 position double check
Nil Internal pilotExternal pilot
Pilot type
R
Nil Non-locking push type (Flush)Non-locking push type (Extended)
Locking type (Tool required)Locking type (Lever)
Pilot valve manual override
ABC
Nil NoneWith light/surge voltage suppressor
Option
Z
Nil NoneCoil rated voltage
<Wiring Example 2> Single/Double mixed wiring (Option)
∗ Mixed wiring is available as an option. Use the manifold specification sheet to specify this.
D side
Dou
ble
Dou
ble
Sin
gle
Sin
gle
Sin
gle
Dou
ble
Sin
gle
Dou
ble
Sin
gle
SI u
nit
1
A B
2
A B
3
A
4
A
5
A
6
A B
7
A
8
A B
9
A
10
0 1 2 3 7 84 5 9 116
SI u
nit o
utpu
t no.
U side
10 11
How to Order Valves
How to Order Manifold
0208 1V
How to Order
Made to OrderSerial Transmission Kit Manifold: EX123/124 Integrated Type (For Output) Serial Transmission System
Stations2
17
2 stations
17 stations
Note 1) Max. 17 stations. Add 1 station for serial unit mounting.
Note 2) Max. 17 stations for all-single wiring. (No. of valves: 16)For the standard double wiring, the maximum number of stations is 9. (No. of valves: 8)
Compatible with SI unit U sidemounating only
Refer to pages 1653 to 1655 for the details of the EX123/124 integrated type (for output) serial transmission system.
1178
P1111-P1228-E.qxd 08.9.2 2:54 PM Page 1178
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Serial Transmission Kit Manifold: EX123/124 Integrated Type (For Output) Serial Transmission System
VV5FS3-01S Model - Stations Symbol - Port size Thread -X279
DimensionsFormula L1 = 33n + 63 L2 = 33n + 75
n: Stations (Max. 17stations)
LL1
L2
n 2129141
3162174
4195207
5228240
6261273
7294306
8327339
9360372
10393405
11426438
12459471
13492504
14525537
15558570
16591603
17624636
Note) Actual number of manifold base stations: Add 1 SI unit mounting station to the number of valve stations.
PE
P
EB
EA
X
32
54
46
27
54.5 44
79.5
44
24.5
24.5
1(P), 5(R1), 3(R2) port
6 x Rc 1/2
(External pilot port)
2 x Rc 1/8
Pilot EXH port2 x Rc 1/8
SMC SMC
B
A
B
A
B
A
B
A A
BB
A
B
A
193354
63.5
123
79.5
2
139
104
49.514
.5
4(A), 2(B) port2n x Rc 1/4, 3/8
Pilot valve manual override
SMC
SERIAL U
NIT
24V0V
+24V24G
DA
DB
DG
FG
B RATE
PW
STATION NO.
LERR.RD
SD
LRUN
MO
DE
LS
V(SI No.EX124U-SMJ1)
SMC
SMC
A
B
SMC
SMC
A
B
SMC
SMC
A
B
SMC
A
B
SMC
A
B
96.5
R4.5
9
286
.5
L1
L2
175
185
165
129
181
Light
1 2 3 4 5 6 7 nStationsD side U side
∗ Use a dripproof plug assembly (AXT100-B04A) for the unused conduit port (G 1/2).
SI unit
EX124�: 4 x G 1/2
Electrical entry
EX123�: 2 x G 1/2
1179
Series VFS30005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:54 PM Page 1179
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Manifold Option Parts — Plug-in type, Non plug-in type
Individual SUP spacer:VVFS3000-P-03-1 (Plug-in type)VVFS3000-P-03-2 (Non plug-in type)
Individual EXH spacer:VVFS3000-R-03-1 (Plug-in type)VVFS3000-R-03-2 (Non plug-in type)
SUP/EXH block plate: AXT636-1A
Throttle valve spacer:VVFS3000-20A-1 (Plug-in type)VVFS3000-20A-2 (Non plug-in type)
Interface regulator/A port regulation:ARBF3050-00-A-1 (Plug-in type)ARBF3050-00-A-2 (Non plug-in type)
Interface regulator/B port regulation:ARBF3050-00-B-1 (Plug-in type)ARBF3050-00-B-2 (Non plug-in type)
Double check spacer:VVFS3000-22A-1 (Plug-in type)VVFS3000-22A-2 (Non plug-in type)
Interface regulator/P port regulation:ARBF3050-00-P-1 (Plug-in type)ARBF3050-00-P-2 (Non plug-in type)
(157
: With
dire
ct m
anua
l ove
rrid
e)
IndividualSUPspacer
(157
: With
dire
ct m
anua
l ove
rrid
e)
IndividualEXHspacer
(168
: With
dire
ct m
anua
l ove
rrid
e)
Interfaceregulator
(168
: With
dire
ct m
anua
l ove
rrid
e)
Interfaceregulator
(168
: With
dire
ct m
anua
l ove
rrid
e)
Interfaceregulator
Throttlevalvespacer
Block disk mounting position
Double checkspacer
(157
: With
dire
ct m
anua
l ove
rrid
e)
1180
Series VFS3000
P1111-P1228-E.qxd 08.9.2 2:54 PM Page 1180
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Replacement Parts
Replacement Parts: Sub Assembly
No.12345678
9
13
Description Material Part no.
No. Description Assembly part no. Component parts Applicable manifold base
10
11
12
Manifold Base Construction — Plug-in type, Non plug-in type
Note) Manifold Base/Construction: Plug-in with terminal block.
Manifold blockassembly
End plate (U side)assemblyEnd plate (D side)assembly
VVFS3000-1A-1-
VVFS3000-1A-2- VVFS3000-2A-1VVFS3000-2A-2VVFS3000-3A-1VVFS3000-3A-2
Manifold block !0, Terminal i, Metal joint q, w, Gasket e, r, O-ring y, u, Receptacle assembly
Manifold block !0, Metal joint q, w, Gasket e, r, O-ring y, uEnd plate (U) !1, Metal joint q, w, O-ring t, yEnd plate (U) !1, Metal joint q, w, O-ring t, y
End plate (D) !2, Metal joint q, w, Gasket eEnd plate (D) !2, Metal joint q, w, Gasket e
Plug-in type
Plug-in type
Plug-in type
Non plug-in type
Non plug-in type
Non plug-in type
0203
0203
Connection fitting AConnection fitting BGasketGasketO-ringO-ringO-ringTerminal assembly
Junction cover assembly
Rubber plug
Steel plateSteel plate
NBRNBRNBRNBRNBR—
For 01TFor 01S�
NBR
VVFS3000-5-1AVVFS3000-5-2VVFS3000-7-1VVFS3000-8
19.8 x 16.6 x 1.6 (End plate)20 x 16 x 2 (Manifold block)
6.2 x 3 x 1.6VVFS3000-6A
VVFS3000-4A- AZ738-22A-
AXT336-9
Stations
Stations
• For increasing the manifold bases, please order the manifold block assembly number of the principal part assembly !0.For plug-in type: The manifold base with terminal stand (integrated with a junction cover) is required with the o junction cover assembly.
End plate (D side)
End plate (U side)
1181
Series VFS30005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:54 PM Page 1181
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model
JIS Symbol2 position
Single
Double
3 positionClosed center
Exhaust center
Pressure center
Double check
Standard SpecificationsCompact yet provides a large flow capacity1/2: C: 12 dm3/(s·bar)
Low power consumption: 1.8 W DCEasy maintenance2 types of sub-plates: Plug-in and non plug-in
Option Specifications
Plug-in type
Non plug-in type
Note 1) Based on JIS B 8375 (once per 30 days) for the minimum operating frequency. Note 2) Based on JIS B 8375-1981 (The value at supply press. 0.5 MPa).Note 3) The figures in the above list are for without sub-plate. In the case of with plug-in sub-plate and with non plug-in sub-plate, add 0.50 kg and 0.43 kg
respectively. Note 4) “Note 1)” and “Note 2)” are with controlled clean air.
Type of actuation
2 po
sitio
n3
posi
tion
Single
Double
Closedcenter
Pressure center
Exhaust center
Model
Plug-in Non plug-in
VFS4100
VFS4200
VFS4300
VFS4400
VFS4500
Portsize C
[dm3/(s·bar)] b CvC
[dm3/(s·bar)] b Cv
1 → 4/2 (P → A/B) 4/2 → 5/3 (A/B → R1/R2) Flow characteristics (1)
VFS4600
VFS4310
VFS4410
VFS4110 111211121011111211126.36.8
121212121011101011116.56.8
0.180.150.180.150.180.180.160.150.220.22——
2.62.82.62.82.52.72.62.92.72.9——
0.200.220.200.220.140.220.150.150.220.22——
2.83.12.83.12.32.62.32.42.72.8——
VFS4210
VFS4510
3 8
3 8
1 2
1 23 81 23 81 23 81 2
VFS46103 81 2
600
600
600
50 or less
50 or less
50 or less
0.82
0.82
1,000
1,200
40 or less
15 or less
0.63
0.75
0.82
200 55 or less 1.71
FluidMaximum operating pressure
Minimum operating pressure
Proof pressureAmbient and fluid temperatureLubricationPilot valve manual overrideShock/Vibration resistance EnclosureCoil rated voltageAllowable voltage fluctuationCoil insulation typeApparent power(Power consumption)
Power consumption DC
InrushHolding
Electrical entry
Val
ve s
pec
ific
atio
ns
Elec
tric
ity s
peci
ficat
ions
Air/Inert gas
1.5 MPa–10 to 60°C (1)
Non-lube (2)
Non-locking push type (Flush)150/50 m/s2 (3)
Type E: Dustproof (level 0), Type F: Dripproof (level 2), Type D: Splashproof (level 4) (4)
100, 200 VAC, 50/60 Hz; 24 VDC–15 to +10% of rated voltage
Class B or equivalent (130°C) (5)
5.6 VA/50 Hz, 5.0 VA/60 Hz3.4 VA (2.1 W)/50 Hz, 2.3 VA (1.5 W)/60 Hz
1.8 W (2.04 W: With light/surge voltage suppressor)Plug-in type
Non plug-in type
1.0 MPa0.1 MPa0.15 MPa
Note 1) Use dry air at low temperatures.Note 2) Use turbine oil Class 1 (ISO VG32), if lubricated.Note 3) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial
direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period)
Note 4) Based on JIS C 0920.Note 5) Based on JIS C 4003.
AC
Conduit terminalGrommet terminal, DIN terminal
2 position3 position
Pilot typeManualoverride
Main valvePilot valve
Coil rated voltage
Porting specificationsOption
External pilot Note)
Direct manual overrideNon-locking push type (Extended), Locking type (Tool required), Locking type (Lever)
110 to 120, 220, 240 VAC, 50/60 Hz12, 100 VDCBottom ported
With light/surge voltage suppressor, Non-rotating DIN terminal
Note) Operating pressure: 0 to 1.0 MPa Pilot pressure 2 position: 0.1 to 1.0 MPa, 3 position: 0.15 to 1.0 MPa
Doublecheck
Max. operating
cycle(cpm)
Responsetime(ms)
Mass(kg)
(Details → P. 1222-3)
(1)(2)
(3)(4)
1182
5 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
Series VFS4000
VFS.qxd 10.11.25 9:49 AM Page 8
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
How to Order Pilot Valve Assembly
2
2
03FPlug-in VFS4 5
ENon plug-in VFS4
Symbol
1
2 position single
2
2 position double
3
3 position closed center
4
3 position exhaust center
5
3 position pressure center
6
3 position double check
O: Plug-in typesub-plate
1: Non plug-in type sub-plate
Body type
Pilot valveManual override
Portingspecifications
Port sizeNil03
Without sub-plate
04∗
Thread typeNilN∗ NPT
Rc
T∗ NPTFF∗ G
∗ Option
Pilot typeNilR∗
∗ Option
Body option01∗
StandardDirect manual override
03
0
1
0
1 1
Body type
OptionNilZP∗
F: Plug-in typeconduit terminal
Electrical entry
E: Grommet terminal D: DIN terminal
Electrical entry
2 0
Manual override Coil rated voltage
SF4 F1 30
How to Order
1 100 VAC, 50/60 Hz2 200 VAC, 50/60 Hz3∗ 110 to 120 VAC, 50/60 Hz4∗ 220 VAC, 50/60 Hz5 24 VDC6∗ 12 VDC7∗ 240 VAC, 50/60 Hz9∗ Other
∗ Option
∗∗ Refer to page 1224 for voltage conversion.
∗ Option
Nil
B∗
A∗
Non-locking push type(Flush)
Non-locking push type(Extended)
Locking type (Tool required)
C∗ Locking type (Lever)
NilB∗
Side portedBottom ported
RcRc
∗ EA, EB: Rc
3 8
3 8
1 2
Internal pilotExternal pilot
∗ Option
Coil rated voltage123∗4∗56∗7∗
100 VAC, 50/60 Hz200 VAC, 50/60 Hz
110 to 120 VAC, 50/60 Hz220 VAC, 50/60 Hz
24 VDC12 VDC
240 VAC, 50/60 Hz9∗ Other
∗ Option
∗ Option
Nil: Non-locking push type(Flush)
NoneWith light/surge voltage suppressor
Q
CE-compliantNil —
CE-compliant
Non-rotating DIN terminal
∗ In the case of w/ “Z”, enter “ZP”.∗ Type “P” is available for DIN type only.
A∗: Non-locking push type(Extended)
B∗: Locking type (Tool required)
C∗: Locking type(Lever)
∗ Reverse pressure: Can be used by external pilot specifications.
∗ In the case of external pilot (Option), bottom piping is not available.
1183
Series VFS40005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
1-02-16-VFS1000.qxd 09.11.2 1:31 PM Page 17
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Cylinder Speed Chart
Double Check Spacer/Specifications
Plug-in type
Check Valve Operation
Non plug-in type
Double check spacer
System
A
800700600500400300200100 0
B
800
900
900
1000
1000
700600500400300200100 0
Bore size
ø50 ø63 ø80 ø100 ø125 ø140 ø160 ø180 ø200 ø250 ø300
Can hold an intermediate cylinder position for an extended timeIf the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools.
Specifications
• In the case of 3 position double check valve (VFS46�0), check the leakage from piping and fittings in between valve and cylinder by means of synthetic detergent solutions, and ensure that there is no such leakage found there. Also check the leakage from cylinder seal and piston seal. If there is any leakage, sometimes the cylinder, when valve is de-energized, can move without stopping at intermediate position.
• Be aware that if the exhaust side is restricted excessively, the intermediate stopping accuracy will decrease and will lead to improper intermediate stops.
• The combination of VFS41010, VFS420
10 and Double check spacer for prevention of falling at the stroke end but cannot hold the intermediate position of the cylinder.
Solenoid valveSystem SilencerSpeed controller
SGP (Steel pipe)Port size x Length
10A x 1Series VFS4000Rc
Series VFS4000Rc
A
B
AN300-03(S = 60 mm2)
AN400-04(S = 90 mm2)
AS420-03(S = 73 mm2)
AS420-04(S = 97 mm2)
15A x 1
3 8
1 2
Double checkspacer part no.
Applicablevalve model
Plug-in typeVVFS4000-22A-1
VFS4400-�F
Non plug-in typeVVFS4000-22A-2
VFS4410-�DVFS4410-�E
Averagespeed(mm/s)
Series CA2Pressure 0.5 MPaLoad factor 50%Stroke 500 mm
Series CS1/CS2Pressure 0.5 MPaLoad factor 50%Cylinder stroke 1000 mm
Perpendicular,upward actuationHorizontalactuation
Use as a guide for selection.Please confirm the actual conditions with SMC Sizing Program.
System Components∗ It is when the cylinder is extending that is meter-out
controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open.
∗ The average velocity of the cylinder is what the stroke is divided by the total stroke time.
∗ Load factor: ((Load weight x 9.8)/Theoretical force) x 100%
Check valve
Piston SUP side pressure (P1)
Operating range
Cylinder side pressure P2 (MPa)
Cylinder side pressure (P2)
SU
P s
ide
pres
sure
P1
(MP
a)
Caution
Note) The CA1 series has been changed to the CA2 series.
1184
Series VFS4000
1-2-16-VFS1000.qxd 09.8.3 5:06 PM Page 4
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Construction
Sub-plate Assembly Part No.
2 position single
3 position closed center/exhaust center/pressure center
2 position double
∗ Mounting bolt and gasket are not included.
Component Parts
23
1Aluminum die-casted
Stainless steel
Aluminum die-casted
4 Resin
Platinum silver—
Platinum silver
Black5 Resin Black6 Resin —7 Resin —8 Resin —9 Stainless steel —10 HNBR —11 Steel —12 — —13 — —
Closed center
Exhaust center
Pressure center
Return springGasket
Pilot valve assembly
Hexagon socket head screwDetent assembly
∗ Refer to “How to Order Pilot Valve Assembly” on page 1183.
No. Description Material Note
Sub-plateBody
Spool/SleeveAdapter plateEnd platePistonJunction coverLight cover
Plug-inNon plug-in
VFS4000-P- VFS4000-S-
03040304
Part no. for mounting bolt and gasketBG-VFS4000
Sub-plate Assembly (For External Pilot) Part No.
Plug-inNon plug-in
VFS4000-P-R VFS4000-S-R
03040304
1185
Series VFS40005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
1-02-16-VFS1000.qxd 10.1.26 2:02 PM Page 1
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Plug-in — 2 Position single/Double/3 Position closed center/Exhaust center/Pressure center/Double check
3 position double check: VFS4600-�F
2 position single: VFS4100-�F
2 position double: VFS4200-�F3 position closed center: VFS4300-�F3 position exhaust center: VFS4400-�F3 position pressure center: VFS4500-�F
2 x ø6.5 mounting hole
2 x ø6.5 mounting hole
mounting hole
2 x ø6.5 mounting hole
Rc 1/8 external pilot port(Only for external pilot)
2(B), 4(A) port
(PE port)
Pilot valvemanual override
(With
dire
ct m
anua
l ove
rrid
e)
Pilot valvemanual override
Pilot valvemanual override
With light/surge voltage suppressor
With light/surge voltage suppressor
With light/surge voltage suppressor
Electrical entry
187 (3 position: 196.5)
Bottom ported
10
7 (
FZ
)
107 (
FZ
)
177 (
FZ
)
(With
direct
manual o
verr
ide)
With
dire
ct m
anua
l ove
rrid
eLight window
Light window
(R1, R2: Rc )3 8
(R1, R2: Rc )3 8
(R1, R2: Rc )3 8
Electrical entry (R1, R2: Rc )3 8Electrical entry
1186
Series VFS4000
P1111-P1228-E.qxd 08.9.2 2:54 PM Page 1186
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Non Plug-in — 2 Position single/Double/3 Position closed center/Exhaust center/Pressure center/Double check
Bottom ported
2 position double: VFS4210-�E, VFS4210-�D3 position closed center: VFS4310-�E, VFS4310-�D3 position exhaust center: VFS4410-�E, VFS4410-�D3 position pressure center: VFS4510-�E, VFS4510-�D
3 position double check: VFS4610-�E, VFS4610-�D
2 position single: VFS4110-�E, VFS4110-�D
2 x ø6.5 mounting hole
2 x ø6.5 mounting hole
2 x ø6.5 mounting hole
2 x ø6.5 mounting hole
2(B), 4(A) port
(PE port)
187 (3 position: 196.5)
Pilot valvemanual override
Pilot valvemanual override
Applicable cabtire cable O.D. ø8 to ø10 Pilot valve
manual override
Applicable cabtire cable O.D. ø8 to ø10
Applicable cabtire cable O.D.ø8 to ø10
DIN terminal
DIN terminal
DIN terminal
With
dire
ct m
anua
l ove
ride
(With
dire
ct m
anua
l ove
rrid
e)
(With
dire
ct m
anua
l ove
rrid
e)
(R1, R2: Rc )3 8
(R1, R2: Rc )3 8
(R1, R2: Rc )3 8(R1, R2: Rc )3 8
1187
Series VFS40005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:55 PM Page 1187
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Plug-in Type: With Terminal Block
Plug-in Type: With Multi-connector
Plug-in Type With: D-sub Connector
Non Plug-in Type: Grommet Terminal, DIN Terminal• Wiring for every valve.
01TVV5FS4
Plug-in typewith terminal block
Port sizeSymbol0304
A, BP, R1, R2
M
106 03Series VFS4000
Manifold 02
10
Stations
Symbol
∗ Option
NilN∗
RcNPT
NPTFG
T∗F∗
∗ Option
Thread type
NilN∗
RcNPT
NPTFG
T∗F∗
∗ Option
Thread type
D01CVV5FS4
Plug-in typewith multi-connector
205 03Series VFS4000
Manifold02
08∗
Stations
∗ Max. 8 stations
Q
CE-compliantNil —
CE-compliant
D01FVV5FS4
Plug-in typewith D-sub connector
106 03Series VFS4000
Manifold
10VV5FS4
Non plug-in type
205 03Series VFS4000
Manifold
• Since lead wires of solenoid valve are connected with the terminals on upper surface of terminal block, corresponding lead wires from power source can be wired at the bottom of terminal block.
• Master connection of power and solenoid valves.
• Quick wiring permits easier installation.
RcRc Rc Mixed
2 stations
10 stations
1 21 2
3 8
Symbol
1 Side2
Passage
R1, R2P
CommonCommon
∗ For bottom ported, Rc is only available.
3 8
Port sizeSymbol0304
A, BP, R1, R2
M
RcRc Rc Mixed
1 21 2
3 8
∗ For bottom ported, Rc is only available.
3 8
NilN∗
RcNPT
NPTFG
T∗F∗
∗ Option
Thread type
Q
CE-compliantNil —
CE-compliant
Port sizeSymbol0304
A, BP, R1, R2
M
RcRc Rc Mixed
1 21 2
3 8
∗ For bottom ported, Rc is only available.
3 8
D side mounting
U side mountingDU
Connector mountingdirection
D side mounting
U side mountingDU
Connector mountingdirection
··· ···
2 stations
8 stations
···
···
02
08∗
Stations
∗ Max. 8 stations
2 stations
8 stations
···
···
Portingspecifications
(A, B)
Bottom∗
Port sizeSymbol0304
A, BP, R1, R2
M
02
10
Stations
Symbol
∗ Option
NilN∗
RcNPT
NPTFG
T∗F∗
∗ Option
Thread type
Q
CE-compliantNil —
CE-compliant
RcRc Rc Mixed
2 stations
10 stations
1 21 2
3 8
Symbol
1 Side2
Passage
R1, R2P
CommonCommon
∗ For bottom ported, Rc is only available.
3 8
··· ···
Portingspecifications
(A, B)
Bottom∗
Symbol
∗ Option
Symbol
1 Side2
Passage
R1, R2P
CommonCommon
Portingspecifications
(A, B)
Bottom∗
Symbol
∗ Option
Symbol
1 Side2
Passage
R1, R2P
CommonCommon
Portingspecifications
(A, B)
Bottom∗
(Wiring specifications: Refer to page 1227.)
• Wide range of interchangeability(MIL Spec D-sub connector termi-nal 25 pcs attached.)
• Quick wiring permits easier installation.
(Wiring specifications: Refer to page 1227.)
Multi-connector
Plug assembly(Option)
Refer to page 1227.
Plug assembly(Option)
Refer to page 1227.
D-sub connector
DIN terminal
Grommet terminal
U side
U side
D side
D side
Terminal block
Q
CE-compliantNil —
CE-compliant
1188
Series VFS4000Manifold Specifications
1-02-16-VFS1000.qxd 09.11.2 1:31 PM Page 18
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Manifold SpecificationsHow to Order Manifold Assembly
∗ With multi-connector, or with D-sub connector: 8 stations max.
Passage/Stations Station 1 Station 5 Station 1010.50.202.511
0.202.9
10.50.202.511
0.202.9
10.50.202.511
0.202.9
Model
VV5FS4
∗ Port size: Rc 1/2
<Example>• Plug-in type with terminal block: 6 stations
(Manifold base) VV5FS4-01T-061-03 ······1(2 position single) VFS4100-5FZ ·············3(2 position double) VFS4200-5FZ ············2(Blanking plate) VVFS4000-10A ··············1
• Non plug-in type: 6 stations(Manifold base) VV5FS4-10-061-04 ········1(2 position single) VFS4110-5D ···············5(3 position exhaust center) VFS4410-5D ····1(Individual EXH spacer) VVFS4000-R-04-2·····1
Please indicate manifold base type, corresponding valve, and option parts.
Flow Characteristics at the Number of Manifold Stations (Operated individually)
,
Base model
Plug-in typeVV5FS4-01
Non plug-in typeVV5FS4-10
Wiring
• With terminal block• With multi-connector• With D-sub connector
• DIN terminal• Grommet terminal
Portingspecifications
A, B port
Side/Bottom
P, R1, R2
1 21 23 8
Port size RcA, B
Stations
2 to 10
Applicable valve model
VFS4�00-�F
VFS4�10-�DVFS4�10-�E
∗
4/2 5/3(A/B R1/R2)
C [dm3/(s·bar)]
bCv
1 4/2(P A/B)
bC [dm3/(s·bar)]
Cv
1189
Series VFS40005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:55 PM Page 1189
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Manifold Option Parts Assembly Manifold Option
For details, refer to page 1193.
For details, refer to page 1195.
For details, refer to page 1198.
Body type Plug-in typeVVFS4000-P-03-1
Non plug-in typeVVFS4000-P-03-2Part no.
Body type Plug-in typeVVFS4000-R-04-1
Non plug-in typeVVFS4000-R-04-2Part no.
Body type Plug-in typeAXT634-10A
Non plug-in typePart no.
Body type Plug-in typeAXT634-11A
Non plug-in typePart no.
EXH block plate SUP block plate
Body type Plug-in typeVVFS4000-20A-1
Non plug-in typeVVFS4000-20A-2Part no.
Part no.Body type Plug-in type
VVFS4000-22A-1Non plug-in typeVVFS4000-22A-2
Body type Plug-in typeARBF4050-00-P-1
Non plug-in typeARBF4050-00-P-2P port regulation
ARBF4050-00-A-1 ARBF4050-00-A-2A port regulationARBF4050-00-B-1 ARBF4050-00-B-2B port regulation
Body type Plug-in typeVVFS4000-10A
Non plug-in typePart no.
Individual SUP spacer An individual SUP spacer set on manifold block can form SUP port for every valve.
Individual EXH spacerAn individual EXH spacer set on manifold block can form EXH port for every valve.(common EXH type)
∗ SUP block plateWhen supplying manifold with more than two different pressures, high and low, insert a block plate in between stations subjected to Plug-in different pressures.
∗ EXH block plateWhen valve exhaust affects the other stations on the circuit or when a reverse pressure valve is used to a standard manifold valve, insert EXH block plate in between stations to separate valve exhaust.
Blanking plateIt is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc.
Throttle valve spacer Needle valve set on the manifold block can control cylinder speed by throttling exhaust.
With control unitPlug-in type/Non Plug-in type• Filter, regulation valve, pressure switch
and air release valve are all combined to form one unit.
• Piping processes are eliminated.
Double check spacerIf the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools.
With exhaust cleanerPlug-in type/Non Plug-in type• Valve exhaust noise dampening: 35 dB
or more.• Oil mist collection: Rate of collection
99.9% or more.• Piping process reduced.
Interface regulatorInterface regulator set on manifold block can regulate the pressure to each valve. (Refer to page 1225 for “Flow Characteristics”.)
Made to OrderManifold with serial transmission kit Plug-in type• Solenoid valve wiring process reduced
considerably.
1190
Series VFS4000
P1111-P1228-E.qxd 08.9.2 2:55 PM Page 1190
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Formula for manifold weight M = 0.565n + 0.923 (kg) n: Stations
Formula for manifold weight M = 0.478n + 0.671 (kg)Stations
L
L1
L2
2156168
3199211
4242254
5285297
6328340
7371383
8414426
9457469
10500512
FormulaL1 = 43 x n + 70L2 = 43 x n + 82
n: Stations
Manifold — Plug-in type, Non plug-in type
Plug-in type (With terminal block): VV5FS4-01T- Station 1- Port size
Non plug-in type: VV5FS4-10- Station 1- Port size
Bottom ported:VV5FS4-01T- Station 2- Port size
Bottom ported:VV5FS4-10- Station 2- Port size
Stations
Stations
Light
Light
Pilot valve manual override
Cable
(External pilot port)
Electrical entry
(Pilot EXH port: PE)
U side
D side
(Pilot EXH port: PE)
(External pilot port)
U side
D side
Pilot valve manual override
1191
Series VFS40005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:55 PM Page 1191
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Formula for manifold weight M = 0.57n + 1.011 (kg) n: Station∗ Wiring specifications: Refer to page 1227.
Formula for manifold weight M = 0.57n + 0.935 (kg)∗ Wiring specifications: Refer to page 1227.
StationsL
L1
L2
2156168
3199211
4242254
5285297
6328340
7371383
8414426
FormulaL1 = 43 x n + 70L2 = 43 x n + 82
Manifold — Plug-in type with multi-connector/D-sub connector
Plug-in type with D-sub connector: VV5FS4-01FD- Station 1- Port size , VV5FS4-01FU- Station 1- Port size
Plug-in type with multi-connector: VV5FS4-01CD- Station 1- Port size , VV5FS4-01CU- Station 1- Port size
Bottom ported:VV5FS4-01 - Station 2- Port sizeCD
CU
Bottom ported:VV5FS4-01 - Station 2- Port sizeFD
FU
n: Stations
U side
D side
U side
D side
Stations
Stations
Plug assembly VVFS2000-30A-�(Option: Refer to page 1227.)
Plug assembly VVZS3000-21A-�(Option: Refer to page 1227.)
(Pilot EXH port: PE)
(External pilot port)
Light
Light
Pilot valve manual override
Pilot valve manual override
(Pilot EXH port: PE)
(External pilot port)
1192
Series VFS4000
P1111-P1228-E.qxd 08.9.2 2:55 PM Page 1192
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Manifold Specifications
Plug-in type
Non plug-in type
CautionWhen using an exhaust cleaner, mount it downwards.
∗ Refer to Best Pneumatics Vol. 6 for Exhaust Cleaner details.
How to OrderExhaust cleaner(Option)
Note 1) With multi-connector, or with D-sub connector: 8 stations max. Note 2) Stations of 5 or more and high frequency of operation should be used with AMC810-14.
Exhaust cleaners AMC610-10 and AMC810-14 are not attached.
10610 03 CDSeries VFS4000
Manifold
VV5FS4
Base type/Electrical entry
01T
01C
01F
10
Symbol
CDCU
D sideU side
Exhaust Exhaust cleaner
mounting direction
D side mountingU side mounting
Exhaust cleanermounting direction
2 stations
10 stations
···
02
10
Stations
NilN∗
RcNPT
NPTFG
T∗F∗
Thread type
Port sizeSymbol
0304
A, BP
M
Exhaust cleaner(Option)
Manifold with Exhaust Cleaner
Manifold
Wiring
Applicable valve model
Porting specificationsRc
Stations
Plug-in type: VV5FS4-01� Non plug-in type: VV5FS4-10
With terminal blockWith multi-connectorWith D-sub connector
DIN terminal Grommet terminal
VFS4�00-�F VFS4�10-�D, VFS4�10-�ECommon SUP/Common EXH
Side: 3/8, 1/2, Bottom: 3/8 (Option)P: 1/2, EXH: 1, 1 1/2
2 to 10 (1)
Applicable exhaust cleaners AMC610-10 (Connecting port size R 1), AMC810-14 (Connecting port size R 1 1/2) (2)
2(B), 4(A) port1(P), 3(R2), 5(R1) port
• Serves to protect working environment.
• Valve exhaust noise dampening: 35 dB or more.
• Collection rate of drainage and oil mist: 99.9% or more.
• Piping work is reduced.
Symbol
Plug-in typewith terminal block
Plug-in typewith multi-connector
Plug-in typewith D-sub connector
Non plug-in type
Symbol Applicable base
DNil
U01C, 01F
01T, 10With connector
D side mountingNone
U side mounting
Connector mounting direction
Base type 01T, 10: 2 to 10 stationsBase type 01C, 01F: 2 to 8 stations
<Example> • Plug-in type with terminal block (6 stations)
(Manifold base)(2 position single)(2 position double)(Blanking plate)(Exhaust cleaner)
• Non plug-in type (6 stations)
13211
VV5FS4-01T-061-03-CDVFS4100-5FZVFS4200-5FZVVFS4000-10AAMC610-10
(Manifold base)(2 position single)(2 position double)(Blanking plate)(Exhaust cleaner)
13211
VV5FS4-10-061-04-CUVFS4110-5EVFS4210-5EVVFS4000-10AAMC810-14
∗ Option ∗ Please indicate exhaust cleaner size or port size.
Q
CE-compliantNil —
CE-compliant
RcRc Rc Mixed
1 21 2
3 8
∗ For bottom ported, Rc is only available.3 8
···
Symbol
1 Side
2 Bottom∗
Passage
R1, R2P
CommonCommon
∗ Option
Portingspecifications
(A, B)
U side
D side
How to Order Manifold Assembly [Example]Add the valve and option part numbers in order starting from the first station on the D side.
∗ ∗ ∗
∗ ∗ ∗
The asterisk denotes the symbol for assem-bly. Prefix it to the part numbers of the sole-noid valve.
1193
Series VFS40005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
1-02-16-VFS1000.qxd 09.11.2 1:31 PM Page 19
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
≅≅
≅≅
D side mounting
U side mounting
D side mounting
U side mounting
StationsL
L1
L2
2156168
3199211
4242254
5285297
6328340
7371383
8414426
9457469
10500512
FormulaL1 = 43 x n + 70L2 = 43 x n + 82
n: Stations
( ): AMC810
( ): AMC810
Manifold with Exhaust Cleaner — Plug-in type, Non plug-in type
Plug-in type: VV5FS4-01T- Station 1- Port size -CDCU
Non plug-in type: VV5FS4-10- Station 1- Port size - CDCU
Stations
Stations
Exhaust cleaner(Option)
Exhaust cleaner(Option)
Pilot valve manual override
Pilot valve manual override
(External pilot port)(Pilot EXH port: PE)
Manualoverride
Manualoverride
Electrical entry
(Pilot EXH port: PE)
U side
U side
D side
D side
U side
U side
D side
D side
1 2R1, 1
(External pilot port)
1194
Series VFS4000
P1111-P1228-E.qxd 08.9.2 2:55 PM Page 1194
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Manifold Specifications
Plug-in type
Non plug-in type
CautionWhen using an air filter with auto-drain or manual drain, mount the filter vertically.
How to Order
∗ With multi-connector, or with D-sub connector: 8 stations max.
VV5FS4 01C D 08 1 03 APSeries VFS4000
Manifold
Air release valve coil ratingNil159
01T01C01F10
Base type/Electrical entry
02
10∗
Stations
Manifold with Control Unit
Control Unit Specifications Control Unit/OptionAir filter (With auto-drain/With manual drain)Filtration degreeRegulatorSet pressure (Outlet pressure)Pressure switch (1)
Set pressure range: OFFDifferentialContact
Max. switch capacity
Max. operating current
Air release valve (Single only)Operating pressure range
5 µm
0.05 to 0.85 MPa
0.1 to 0.6 MPa
0.1 to 1.0 MPa
0.08 MPa or less1a
Indicator light LED (RED)2 VA AC, 2 W DC
24 VAC/DC or less: 50 mA48 VAC/DC: 40 mA100 VAC/DC: 20 mA
Air releasevalve spacer
Pressureswitch
Blankingplate
Filterelement
<Plug-in type>VVFS4000-24A-1R (D side mounting)<Non plug-in type>VVFS4000-24A-2R (D side mounting)
IS1000P-2-1Filter regulator
Pressure switchRelease valve
MP2-3MP3-2
VVFS4000-24A-1011104-5B
Note 1) Voltage: 24 VDC to 100 VACInner voltage drop: 4 V
Note 2) Combination of a valve VFS41�� (single) and a release valve spacer can be used as an air release valve.
Note 3) The non plug-in type cannot be mounted afterwards.
Air filter with auto-drainControl equipment
Symbol
Air filter with manual drainRegulatorAir release valvePressure switchBlanking plate (Air release valve)Blanking plate (Filter, Regulator)Blanking plate (Pressure switch)
Number of manifold blocksrequired for mounting (stations)
A AP M MP F G C E
Control unit type
None (F, G type only)
100 VAC, 50/60 Hz24 VDCOther
Q
CE-compliantNil —
CE-compliant
Plug-in type with terminal blockPlug-in type with multi-connectorPlug-in type with D-sub connector
Non plug-in type
Symbol Applicable base
DNil
U01C, 01F
01T, 10With connector
D side mountingNone
U side mounting
Connector mounting direction
Port size
Thread type
∗ Base type 01T, 10: 2 to 10 stations
Base type 01C, 01F: 2 to 8 stations
Symbol
0304
A, BP, R1, R2
RcRcRc
M Mixed
1 21 2
3 8
RcNPT
NPTFG
Nil N∗ T∗ F∗
<Example>
(Manifold base)(2 position single)(2 position double)
• Non plug-in type: In order to mount control unit, it requires 2 stations.(Manifold base)(2 position single)
142
14
VV5FS4-01T-081-03-AP5VFS4100-5FZVFS4200-5FZ
VV5FS4-10-061-03-AVFS4110-5D
2 stations
10 stations
∗ For bottom ported, Rc is only available.
3 8
• Control unit (Filter, Regulator, Pres-sure switch, Air release valve) are all standardized to the one unit, and can be mounted on the mani-fold base without any attachments.
• Piping processes are eliminated.
··· ··· Symbol
Symbol
1 Side
2 Bottom∗
Passage
R1, R2P
CommonCommon
∗ Option
∗ Option
Portingspecifications
(A, B) 2 2 2 2 2 2 2 1
Nil
Manifold
Wiring
Applicable valve model
Porting specificationsRc (PT)
Stations
Plug-in type: VV5FS4-01� Non plug-in type: VV5FS4-10With terminal block
With multi-connectorWith D-sub connector
DIN terminal Grommet terminal
VFS4�00-�F VFS4�10-�D, VFS4�10-�ECommon SUP, Common EXH
Side: 3/8, 1/2, Bottom: 3/8Side: 1/2
2 to 10 ∗
2(B), 4(A) port1(P), 3(R2), 5(R1) port
How to Order Manifold Assembly [Example]Add the valve and option part numbers in order starting from the first station on the D side.
∗ ∗
∗
The asterisk denotes the symbol for assembly. Prefix it to the part numbers of the solenoid valve.
• Plug-in type with terminal block: In order to mount control unit, it requires 2 stations.
(2)
(3)
1195
Series VFS40005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
1-02-16-VFS1000.qxd 09.11.2 1:31 PM Page 20
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
≅
≅
≅
≅
Example for manifold
Manifold with Control Unit — Plug-in type, Non plug-in type
Example for manifold
StationsL
L1
L2
L3 (MP)L3 (AP)
3199211
4242254
5285297
6328340
7371383
8414426
9457469
10500512
FormulaL1 = 43 x n + 70
n: Stations
L2 = 43 x n + 82385.5 428.5 471.5 514.5 557.5 600.5 643.5 686.5427 470 513 556 599 642 685 728
L3 = 43 x n + 256.5L3 = 43 x n + 298
Plug-in type: VV5FS4-01T- Station 1- Port size -AP Voltage for release valve
Non plug-in type: VV5FS4-10- Station 1- Port size -AP Voltage for release valve
Pilot valve manual override
Pilot valve manual override
Individual EXH spacer
Double check spacer
Individual SUP spacer
Air
filte
rre
gula
tor
Control unit
Outlet for check
Pressure switch
Air release valve
Pressure switch
Air release valve
Pressure switch
Air
rele
ase
valv
e
Individual EXH spacer
Double check spacer
Individual SUP spacer
Air
filte
rre
gula
tor
Control unit
Outlet for check
Pressure switch
Air
rele
ase
valv
e
Pilot valvemanual override
Stations
Stations
Pilot EXH port: PE
Electrical entry
(Po port)
(External pilot port)
U side
U side
D side
D side
222
(180
.5: -
MP
)(1
80.5
: -M
P)
Pilot EXH port: PE
(External pilot port)
(Po port)
1196
Series VFS4000
P1111-P1228-E.qxd 08.9.2 2:55 PM Page 1196
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
1197
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:55 PM Page 1197
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
VV5FS4 X19901S
Nil RcNPT
NPTFG
Thread type
NTF
Plug-in typeSerial transmission kit
Stations2
10
2 stations
10 stationsNote 1) Max. 10 stations. Add 1 station for serial unit mounting.Note 2) Max. 10 Stations: For single and double mixed wiring. (No. of
valves: 9) Max. 9 stations: For standard double wiring (No. of valves: 8)
Combination symbol
Symbol
SideBottom
Port specification
P R1, R2
Pipingspecification
A, B
CommonCommon12∗
∗ Option
Port sizeSymbol
0304M
A, BP, R1, R2
Rc 1/2
∗ For bottom ported: Rc 1/8 only
Rc 3/8Rc 1/2Mixed
SI unit mounting positionDU
D side mountingU side mounting
Applicable models
For U side mouning For D side mouning—
EX123U-SUW1EX123U-SUH1EX123U-SSL1EX123U-SSL2EX124U-SDN1EX124U-SCS1EX124U-SCS2EX124U-SMJ1
—EX123D-SUW1EX123D-SUH1EX123D-SSL1EX123D-SSL2EX124D-SDN1EX124D-SCS1EX124D-SCS2EX124D-SMJ1
DescriptionSI unit part no.
Without SI unitNKE Corporation: Uni-wire System (16 outputs)NKE Corporation: Uni-wire H System (16 outputs)SUNX Corporation: S-LINK System (16 outputs)SUNX Corporation: S-LINK System (8 outputs)DevieNet (2 power supply systems)OMRON Corporation: CompoBus/S (16 outputs) (2 power supply systems)OMRON Corporation: CompoBus/S (8 outputs) (2 power supply systems) CC-Link (2 power supply systems)
Symbol
0F1HJ1J2QR1R2V
� Correspondence of SI unit output numbers and solenoid valve coils<Wiring Example 1> Double wiring (Standard)
D side
Dou
ble
Dou
ble
Sin
gle
Sin
gle
Sin
gle
Dou
ble
Sin
gle
Sin
gle
SI u
nit
1
A B
2
A B
3
A B
4
A B
5
A B
6
A B
7
A B
8
A B
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
9
SI u
nit o
utpu
t no.
U side
<Wiring Example 2> Single/Double mixed wiring (Option)
∗ Mixed wiring is available as an option. Use the manifold specification sheet to specify this.
VFS4 00 5 F
24 VDC
Symbol123456
2 position single2 position double
3 position closed center3 position exhaust center3 position pressure center3 position double check
Nil Internal pilotExternal pilot
Pilot type
R
Nil Non-locking push type (Flush)Non-locking push type (Extended)
Locking type (Tool required)Locking type (Lever)
Pilot valve manual override
ABC
Nil NoneWith light/surge voltage suppressor
Option
Z
Nil NoneCoil rated voltage
D side
Dou
ble
Dou
ble
Sin
gle
Sin
gle
Sin
gle
Dou
ble
Sin
gle
Dou
ble
Sin
gle
SI u
nit
1
A B
2
A B
3
A
4
A
5
A
6
A B
7
A
8
A B
9
A
10
0 1 2 3 7 84 5 9 116
SI u
nit o
utpu
t no.
U side
10 11
How to Order Valves
How to Order Manifold
Refer to pages 1653 to 1655 for the details of the EX123/124 integrated type (for output) serial transmission system.
03108VU
Made to OrderSerial Transmission Kit Manifold: EX123/124 Integrated Type (For Output) Serial Transmission System
How to Order
SI unit can be mounted oneither U or D side.
1198
P1111-P1228-E.qxd 08.9.2 2:55 PM Page 1198
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
DimensionsFormula L1 = 43n + 70 L2 = 43n + 82
n: Stations (Max. 10 stations)
LL1
L2
n 2156168
3199211
4242254
5285297
6328340
7371383
8414426
9457469
10500512
Note) Actual number of manifold base stations: Add 1 SI unit mounting station to the number of valve stations.
1 2 3 4 5 6 7 nStationsD side U side
XE
AE
B
P
PE
38
18
86
28 2424
23
63.5
42
1(P), 5(R3), 3(R1)
6 x Rc 1/2
(Electrical entry)
2 x G 1 1/4 (Pilot EXH port: PE)2 x Rc 1/8
SMC
A
SMC
A
SMC
A
SMC
A
SMC
A
SMC
B
SMC
B
SMC
B
SMC
BB
SMC
SERIAL U
NIT
24V0V
+24V24G
DA
DB
DG
FG
B RATE
PW
STATION NO.
LERR.RD
SD
LRUN
MO
DE
LS
V(SI No.EX124U-SMJ1)
5.5
155.
5
95.5
187
202.
5166
105
55
47459
6
L2
L1
91.54319
6.5
205.
5
B
A
B
A
B
A
B
A
B
A
B
A
B
A
SMC
3043
33
62.5
141.
00
74.0
0
150.
5
115.
5
91.5
58
1814
3
Manual override
4(A), 2(B) port2n x Rc 3/8, 1/2
∗ Use a dripproof plug assembly (AXT100-B04A) for the unused conduit port (G 1/2).
SI unit
EX124�: 4 x G 1/2
Electrical entry
EX123�: 2 x G 1/2
Serial Transmission Kit Manifold (EX123/124): Plug-in Type
VV5FS4-01S Mounting position Model - Stations Symbol - Port size Thread -X199
1199
Series VFS40005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:55 PM Page 1199
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Manifold Option Parts — Plug-in type, Non plug-in type
( ): EXH block plate
Individual EXH spacer:VVFS4000-R-04-1 (Plug-in type)VVFS4000-R-04-2 (Non plug-in type)
SUP block plate: AXT634-10AEXH block plate: AXT634-11A
Throttle valve spacer:VVFS4000-20A-1 (Plug-in type) VVFS4000-20A-2 (Non plug-in type)
Interface regulator/A port regulation:ARBF4050-00-A-1 (Plug-in type)ARBF4050-00-A-2 (Non plug-in type)
Interface regulator/B port regulation:ARBF4050-00-B-1 (Plug-in type)ARBF4050-00-B-2 (Non plug-in type)
Interface regulator/P port regulation:ARBF4050-00-P-1 (Plug-in type)ARBF4050-00-P-2 (Non plug-in type)
Individual SUP spacer:VVFS4000-P-03-1 (Plug-in type)VVFS4000-P-03-2 (Non plug-in type)
Double check spacer:VVFS4000-22A-1 (Plug-in type)VVFS4000-22A-2 (Non plug-in type)
(172
: With
dire
ct m
anua
l ove
rrid
e)16
9
IndividualEXHspacer
(179
: With
dire
ct m
anua
l ove
rrid
e)
Interfaceregulator
(195
: With
dire
ct m
anua
l ove
rrid
e)
Interfaceregulator
Interfaceregulator
(195
: With
dire
ct m
anua
l ove
rrid
e)(1
95: W
ith d
irect
man
ual o
verr
ide)
(172
: With
dire
ct m
anua
l ove
rrid
e)
Block plate mounting position
Double checkspacer
Individual SUPspacer
Throttle valvespacer
1200
Series VFS40005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
P1111-P1228-E.qxd 08.9.2 2:55 PM Page 1200
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
12345678
9
13
10
11
12
Note) Manifold Base/Construction: Plug-in type with terminal block.
Manifold Base Construction — Plug-in type, Non Plug-in type
Replacement Parts: Sub Assembly
Replacement Parts
• For increasing the manifold bases, please order the manifold block assembly number of the principal part assembly !0.For plug-in type: The manifold base with terminal stand (integrated with a junction cover) is required with the o junction cover assembly.
No. DescriptionConnection fitting AConnection fitting BGasketGasketGasketO-ringO-ringTerminal assembly
Junction cover assembly
Rubber plug
MaterialSteel plateSteel plate
NBRNBRNBRNBRNBR—
For 01TFor 01SU
NBR
Part no.VVF4000-5-1AVVF4000-5-2
VVF4000-7 (End plate)VVF4000-7-1 (Manifold block)
VVF4000-8AS568-011
P-3VVF4000-6A
VVF4000-4A- AZ738-30A-
AXT336-9
Stations
Stations
No. Description Assembly part no. Component parts Applicable manifold base
Manifold blockassembly
End plate (U side)assembly
End plate (D side)assembly
VVF4000-1A-1-
VVF4000-1A-2- VVF4000-2A-1VVF4000-2A-2
VVF4000-3A-1
VVF4000-3A-2
Manifold block !0, Terminal i, Metal joint q, w, Gasket r, Receptacle assembly
Manifold block !0, Metal joint q, w, Gasket rEnd plate (U) !1, Metal joint q, wEnd plate (U) !1, Metal joint q, w
End plate (D) !2, Metal joint q, w, Gasket e, t, O-ring y, u
End plate (D) !2, Metal joint q, w, Gasket e, t, O-ring t, y
Plug-in type
Plug-in type
Plug-in type
Non plug-in type
Non plug-in type
Non plug-in type
0304
0304
End plate (D side)
End plate (U side)
Manifold block
1201
Series VFS40005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:55 PM Page 1201
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model
JIS Symbol
Plug-in type
Non plug-in type
VFS5300
VFS5400
VFS5500
VFS5100
VFS5200
1516171516171416161416171416189.09.09.0
0.300.150.150.300.150.150.250.250.250.320.170.200.300.230.25———
0.300.150.130.300.150.130.240.240.230.250.180.130.310.220.22———
4.14.54.74.14.54.74.14.14.13.54.14.13.84.14.3———
3.73.73.93.73.73.94.04.14.13.83.84.23.73.94.6———
1519201519201416161416171416179.09.09.0
VFS5600
VFS5310
VFS5410
VFS5110
VFS5210
VFS5510
VFS5610
3 8
3 8
1 23 4
1 23 43 81 23 43 81 23 43 81 23 43 81 23 4
300
300
300
600
600
180
1.16
1.14
0.88
1.06
1.14
1.99
Note 1) Based on JIS B 8375 (once per 30 days) for the minimum operating frequency. Note 2) Based on JIS B8375-1981. (The value at supply pressure 0.5 MPa.)Note 3) The figures in the above list are without sub-plate. In the case of with plug-in sub-plate and, with non plug-in sub-plate add Rc 3/8, 1/2—0.744 kg, Rc
3/4—0.966 kg and Rc 3/8, 1/2—0.577 kg, Rc 3/4—0.823 kg respectively.Note 4) “Note 1) ” and “Note 2) ” are with controlled clean air.
Type of actuation
2 po
sitio
n3
posi
tion
Single
Double
Doublecheck
Closedcenter
Pressure center
Exhaust center
Model
Plug-in Non plug-in
PortsizeRc
C[dm3/(s·bar)] b Cv
C[dm3/(s·bar)] b Cv
1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) Flow characteristics
55 or less
55 or less
55 or less
45 or less
25 or less
60 or less
Standard SpecificationsCompact yet provides a large flow capacity3/4: C: 20 dm3/(s·bar)
Low power consumption: 1.8 W DC
Easy maintenance2 types of sub-plates: Plug-in and non plug-in
Option Specifications
FluidMaximum operating pressureMinimum operating pressureProof pressureAmbient and fluid temperatureLubricationPilot valve manual overrideShock/Vibration resistance EnclosureCoil rated voltageAllowable voltage fluctuationCoil insulation typeApparent power(Power consumption)
Power consumption DC
InrushHolding
Electrical entry
Val
ve s
pec
ific
atio
ns
Elec
tric
ity s
peci
ficat
ions
Air/Inert gas
1.5 MPa–10 to 60°C (1)
Non-lube (2)
Non-locking push type (Flush)150/50 m/s2 (3)
Type E: Dustproof (Level 0), Type F: Dripproof (Level 2), Type D: Splashproof (Level 4) (4)
100, 200 VAC, 50/60 Hz; 24 VDC–15 to +10% of rated voltage
Class B or equivalent (130°C) (5)
5.6 VA/50 Hz, 5.0 VA/60 Hz3.4 VA (2.1 W)/50 Hz, 2.3 VA (1.5 W)/60 Hz
1.8 W (2.04 W: With light/surge voltage suppressor)Plug-in type
Non plug-in type
1.0 MPa0.1 MPa
Note 1) Use dry air at low temperatures.Note 2) Use turbine oil Class 1 (ISO VG32), if lubricated.Note 3) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial
direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period)
Note 4) Based on JIS C 0920. Note 5) Based on JIS C 4003.
AC
Conduit terminalGrommet terminal, DIN terminal
Pilot type
Manualoverride
Main valvePilot valve
Coil rated voltage
Porting specificationsOption
External pilot Note)
Direct manual overrideNon-locking push type (Extended), Locking type (Tool required), Locking type (Lever)
110 to 120, 220, 240 VAC (50/60 Hz) 12, 100 VDCBottom ported
With light/surge voltage suppressor, Non-rotating DIN terminal
Note) Operating pressure: 0 to 1.0 MPa Pilot pressure: 0.1 to 1.0 MPa
2 positionSingle
Double
3 positionClosed center
Exhaust center
Pressure center
Double check
Max. operating
cycle(cpm)
(Details → P. 1222-4)
Responsetime(ms)
Mass(kg)
(1)(2) (3)
1202
5 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
Series VFS5000
VFS.qxd 10.11.25 9:49 AM Page 9
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
How to Order Pilot Valve Assembly
1 04FVFS5 2
DVFS5
Symbol
1
2 position single
2
2 position double
3
3 position closed center
4
3 position exhaust center
5
3 position pressure center
6
3 position double check
O: Plug-in type sub-plate
1: Non plug-in type sub-plate
Body type
Pilot valveManual override
Port sizeNil0304
Thread typeNilN∗ NPT
Rc
T∗ NPTFF∗ G
∗ Option
06
Pilot typeNilR∗
Internal pilotExternal pilot
∗ Option
Body option01∗
StandardDirect manual override
∗ Option
Coil rated voltage
∗ Option ∗ Option
Nil: Non-locking push type(Flush)
06
0
1
0
5
Body type
OptionNilZP∗
ZP∗
A∗: Non-locking push type(Extended)
B∗: Locking type (Tool required)
C∗: Locking type(Lever)
F: Plug-in typeconduit terminal
Electrical entry
1 0
∗ Option
Manual override Coil rated voltage
SF4 F1 30
How to Order
Portingspecifications
NilB∗
Plug-in
Non plug-in
Side portedBottom ported
Without sub-plateRcRc
3 81 2
Rc 3 4
123∗4∗56∗7∗
100 VAC, 50/60 Hz200 VAC, 50/60 Hz
110 to 120 VAC, 50/60 Hz220 VAC, 50/60 Hz
24 VDC12 VDC
240 VAC, 50/60 Hz
9∗ Other
NoneWith light/surge voltage suppressor
Q
CE-compliantNil —
CE-compliant
Non-rotating DIN terminal
Light/Surge Voltage SuppressorNon-rotating DIN terminal
E: Grommet terminal D: DIN terminal
Electrical entry
∗ In the case of external pilot (Option), bot-tom piping is not available.
∗ Type “P”, “ZP” is available for DIN type only.
1 100 VAC, 50/60 Hz2 200 VAC, 50/60 Hz3∗ 110 to 120 VAC, 50/60 Hz4∗ 220 VAC, 50/60 Hz5 24 VDC6∗ 12 VDC7∗ 240 VAC, 50/60 Hz9∗ Other
∗∗ Refer to page 1224 for voltage conversion.
∗ Option
Nil
B∗
A∗
Non-locking push type(Flush)
Non-locking push type(Extended)
Locking type (Tool required)
C∗ Locking type (Lever)
1203
Series VFS50005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
1-02-16-VFS1000.qxd 09.11.2 1:31 PM Page 21
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Cylinder Speed Chart
Plug-in type
Specifications Check Valve Operation
Non plug-in type
Caution
Double check spacer
Series
VFS5100-06
800700600500400300200100 0
Bore size
ø125 ø140 ø160 ø180 ø200 ø250 ø300
Series CS1SGP20A x 1 m
AS500-06AN500-06
Tube bore x LengthSpeed controllerSilencer
VFS5100-06
Conditions
VVFS5000-22A-1 VVFS5000-22A-2
Double Check Spacer/Specifications
Can hold an intermediate cylinder position for an extended timeIf the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools.
• In the case of 3 position double check valve (VFS56�0), check the leakage from piping and fittings in between valve and cylinder by means of synthetic detergent solutions, and ensure that there is no such leakage found there. Also check the leakage from cylinder seal and piston seal. If there is any leakage, sometimes the cylinder, when valve is de-energized, can move without stopping at intermediate position.
• Be aware that if the exhaust side is restricted excessively, the intermediate stopping accuracy will decrease and will lead to improper intermediate stops.
• The combination of VFS51 0, VFS52 0 and a double check spacer can be used as prevention of falling at the stroke end but cannot hold the intermediate position of the cylinder.
Series CS1/CS2Pressure 0.5 MPaLoad factor 50%Stroke 300 mm
∗ It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open.
∗ The average velocity of the cylinder is what the stroke is divided by the total stroke time.∗ Load factor: ((Load weight x 9.8)/Theoretical force) x 100%
Use as a guide for selection.Please confirm the actual conditions with SMC Sizing Program.
Averagespeed(mm/s)
Perpendicular,upward actuationHorizontalactuation
01
01
Check valve
Piston SUP side pressure (P1)
Operating range
Cylinder side pressure P2 (MPa)
Cylinder side pressure(P2)
SU
P s
ide
pres
sure
P1
(MP
a)
Double checkspacer part no.
Applicablevalve model
Plug-in type
VFS5400-�F
Non plug-in type
VFS5410-�DVFS5410-�E
1204
Series VFS5000
P1111-P1228-E.qxd 08.9.2 2:55 PM Page 1204
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Construction
Sub-plate Assembly Part No.
∗ Mounting bolt and gasket are not included.
Plug-in
Non plug-in
VFS5000-P-
VFS5000-S-
030406030406
Sub-plate Assembly (For External Pilot) Part No.
Plug-in
Non plug-in
VFS5000-P-R
VFS5000-S-R
030406030406
Component PartsNo.
23
1Description Note
4—
56 —7 —8 —9 —10 —11 —12 — —13 — —
∗ Refer to “How to Order Pilot Valve Assembly” on page 1203.
2 position single 2 position double
3 position closed center/exhaust center/pressure centerClosed center
Exhaust center
Pressure center
Aluminum die-castedStainless steel
MaterialAluminum die-casted Platinum silver
Platinum silver
BlackBlack
Sub-plateBody
Spool/SleeveAdapter plateEnd plate
ResinPistonResin
ResinResin
Junction coverResinLight cover
Return springGasket
Pilot valve assembly
Stainless steelNBR
Hexagon socket head screw SteelDetent assembly
Part no. for mounting bolt and gasketBG-VFS5000
1205
Series VFS50005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:55 PM Page 1205
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Plug-in — 2 Position single/Double/3 Position closed center/Exhaust center/Pressure center/Double check
3 position double check: VFS5600-�F
2 position single: VFS5100-�F
2 position double: VFS5200-�F3 position closed center: VFS5300-�F3 position exhaust center: VFS5400-�F3 position pressure center: VFS5500-�F
3 4( ): Rc
3 4( ): Rc 3 4( ): Rc
2 x ø7mounting hole
2 x ø7 mountinghole
2 x ø7 mountinghole
Bottom ported
3(R2), 5(R1): Rc 1/2
With light/surgevoltage suppressor
With light/surgevoltage suppressor
With light/surgevoltage suppressor
Pilot valvemanual override
Direct manual override
G 1/2 electrical entry
Pilot valvemanual override
Direct manual override
G 1/2electrical entry
Pilot valvemanual override
Direct manual override
G 1/2electrical entry
Rc 1/8 external pilot(Port size: Rc 3/8, 1/2)
(Pilot EXH port)
Rc 1/8 external pilot
(Port size: Rc 3/4)
219.3 (218) 3 position 227.3 (226)
2(B
), 4
(A)
port
1206
Series VFS5000
P1111-P1228-E.qxd 08.9.2 2:55 PM Page 1206
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Non Plug-in — 2 Position single/Double/3 Position closed center/Exhaust center/Pressure center/Double check
2 position double: VFS5210-�E, VFS5210-�D3 position closed center: VFS5310-�E, VFS5310-�D3 position exhaust center: VFS5410-�E, VFS5410-�D3 position pressure center: VFS5510-�E, VFS5510-�D
3 position double check: VFS5610-�E, VFS5610-�D
2 position single: VFS5110-�E, VFS5110-�D
( ): Rc 3/4
( ): Rc 3/4 ( ): Rc 3/4
2 x ø7 mountinghole
2 x ø7 mountinghole
Rc 3/4: 3(R2), Rc 1/2: 5(R1)
Applicable cabtire cable O.D.ø8 to ø10
Pilot valvemanual override
Direct manual override
Applicable cabtire cable O.D.ø8 to ø10
Pilot valvemanual override
Direct manualoverride
Applicable cabtire cable O.D.ø8 to ø10
Pilot valvemanual override
Direct manualoverride
101.5 (3 position: 109.5)
Rc 1/8external pilot(Port size Rc 3/8, 1/2)
Rc 1/8 external pilot(Port size: Rc 3/4)
2(B
), 4
(A)
port
G 1 2
2 x ø7 mounting hole
2 x Rc 1/8(Pilot EXH port)
1207
Series VFS50005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:55 PM Page 1207
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
∗ For bottom ported, Rc is only available.
∗ For bottom ported, Rc is only avail-able.
∗ For bottom ported, Rc is only available.
NilN∗
RcNPT
NPTFG
T∗F∗
∗ Option
Thread type
Q
CE-compliantNil —
CE-compliant
Port sizeSymbol
0406
A, BP, R1, R2
M Mixed
1 2
RcRc Rc 3 43 4
1 2
∗ For bottom ported, Rc is only avail-able.
NilN∗
RcNPT
NPTFG
T∗F∗
∗ Option
Thread type
Q
CE-compliantNil —
CE-compliant
Port sizeSymbol
0406
A, BP, R1, R2
M Mixed
1 2
RcRc Rc 3 43 4
1 2
Plug-in Type: With Terminal Block
Plug-in Type: With Multi-connector
Plug-in Type: With D-sub Connector
Non Plug-in Type: Grommet Terminal, DIN Terminal
01TVV5FS5
Plug-in typewith terminal block Port size
Symbol
0406
A, BP, R1, R2
M Mixed
106 04Series VFS5000
Manifold
···
2 stations
10 stations
···
02
10
Stations
NilN∗
RcNPT
NPTFG
T∗F∗
∗ Option
Thread type
NilN∗
RcNPT
NPTFG
T∗F∗
∗ Option
Thread type
D
Connector mounting
direction
01CVV5FS5
Plug-in typewith multi-connector
205 04Series VFS5000
Manifold Q
CE-compliantNil —
CE-compliant
D01FVV5FS5
Plug-in typewith D-sub connector
106 04Series VFS5000
Manifold
10VV5FS5
Non plug-in type
205 04Series VFS5000
Manifold
• Since lead wires of solenoid valve are connected with the terminals on upper surface of terminal block, corresponding lead wires from power source can be wired at the bottom of terminal
block.
• Master connection of power and solenoid valves.
• Quick wiring permits easier installation.
• Wide range of interchangeability(MIL Spec. D-sub connector terminal 25 pcs attached.)
• Quick wiring permits easier installation.
• Wiring for every valve.
1 2
Stations
Symbol
∗ Max. 8 stations
(Wiring specifications: Refer to page 1227.)
(Wiring specifications: Refer to page 1227.)
∗ Option
RcRc Rc 3 43 4
1 2
Q
CE-compliantNil —
CE-compliant
Port sizeSymbol
0406
A, BP, R1, R2
M Mixed
1 2
RcRc Rc 3 43 4
1 2
2 stations
8 stations
···
Stations02
10
···
2 stations
10 stations
···
∗ Option
Symbol
1 Side2
Passage
R1, R2P
CommonCommon
Portingspecifications
(A, B)
Bottom∗
Symbol
∗ Option
Symbol
1 Side2
Passage
R1, R2P
CommonCommon
Portingspecifications
(A, B)
Bottom∗
Symbol
Symbol
1 Side2
Passage
R1, R2P
CommonCommon
Portingspecifications
(A, B)
Bottom∗
∗ Option
Symbol
Symbol
1 Side2
Passage
R1, R2P
CommonCommon
Portingspecifications
(A, B)
Bottom∗
U side
U side
D side
D side
Multi-connector
D-sub connector
DIN terminal
Grommet terminal
Plug assembly(Option)
Refer to page 1227.
Plug assembly(Option)
Refer to page 1227.
02
08∗
···
Stations
∗ Max. 8 stations
2 stations
8 stations
···
02
08∗
···
D side mounting
U side mountingDU
Connector mounting
directionD side mounting
U side mountingDU
1208
Series VFS5000Manifold Specifications
1-02-16-VFS1000.qxd 09.11.2 1:31 PM Page 22
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Manifold Option Parts Assembly Manifold Option
For details, refer to page 1214.
For details, refer to page 1212.
Individual SUP spacer An individual SUP spacer set on manifold block can form SUP port for every valve.
Manifold Specifications
Flow Characteristics at the Number of Manifold Stations (Operated individually)
Individual EXH spacerAn individual EXH spacer set on manifold block can form EXH port for every valve. (common EXH type)
SUP block plateWhen supplying manifold with more than two different pressures, high and low, insert a block plate in between stations subjected to different pressures.
EXH block plateWhen valve exhaust affects the other stations on the circuit or when a reverse pressure valve is used on a standard manifold valve, insert EXH block plate in between stations to separate valve exhaust.
Blanking plate It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc.
Double check spacerIf the double check spacer with a built-in double check valve is combined, it will enable the cylinder to stop in the intermediate stroke and maintain its position for a long time without being affected by the leakage between the spools.
Throttle valve spacer Needle valve set on the manifold block can control cylinder speed by throttling exhaust.
EXH block plate SUP block plate
Rc,
Base model
Plug-in typeVV5FS5-01�
Non plug-in typeVV5FS5-10
Wiring
• With terminal block• With multi-connector• With D-sub connector
• DIN terminal• Grommet terminal
A, B port P, R1, R2
3 4 1 2 3 4
Port size RcA, B
Stations
VFS5�00-�F
VFS5�10-�DVFS5�10-�E
Rc
∗With multi-connector, or with D-sub connector: 8 stations max.
∗ Port size: Rc 1/2, 3/4
4/2 5/3(A/B R1/R2)
C [dm3/(s·bar)]b
Cv
Passage/Stations
1 4/2(P A/B)
Station 1 Station 5 Station 10
bC [dm3/(s·bar)] 15.0
0.204.0
16.00.204.2
15.00.204.0
16.00.204.2
15.00.204.016.00.204.2
Cv
Model
VV5FS5
Body type Plug-in typeVVFS5000-P-04-1
Non plug-in typeVVFS5000-P-04-2Part no.
Body type Plug-in type
VVFS5000-20A-1
Non plug-in type
VVFS5000-20A-2Part no.
Body type Plug-in typeVVFS5000-R-04-1
Non plug-in typeVVFS5000-R-04-2Part no.
Body type Plug-in type
VVFS5000-22A-1
Non plug-in type
VVFS5000-22A-2Part no.
Body type Plug-in typeAXT628-12A
Non plug-in typePart no.
Body type Plug-in typeARBF5050-00-P-1
Non plug-in typeARBF5050-00-P-2P port regulation
ARBF5050-00-A-1 ARBF5050-00-A-2A port regulationARBF5050-00-B-1 ARBF5050-00-B-2B port regulation
Body type Plug-in typeAXT512-14-1A
Non plug-in typePart no.
Body type Plug-in typeVVFS5000-10A
Non plug-in typePart no.
<Example>• Plug-in type with terminal block: 6 stations
(Manifold base) VV5FS5-01T-061-04 ······1(2 position single) VFS5100-5FZ ··········· 3(2 position double) VFS5200-5FZ ··········2(Blanking plate) VVFS5000-10A ·············1
• Non plug-in type: 6 stations(Manifold base) VV5FS5-10-061-04 ········1(2 position single) VFS5110-5D ·············5(3 position exhaust center) VFS5410-5D ········1(Individual EXH center) VVFS5000-R-04-2 ····1
How to Order Manifold AssemblyPlease indicate manifold base type, corresponding valve, and option parts.
Portingspecifications
Side/Bottom 2 to 10∗
Applicablevalve model
With exhaust cleanerPlug-in type/Non plug-in type• Valve exhaust noise dampening: 35 dB
or more.• Oil mist collection: Rate of collection
99.9% or more.• Piping process reduced.
Interface regulatorInterface regulator set on manifold block can regulate the pressure to each valve. (In the event of using, refer to “Flow Characteristics” on page 1225).
Made to OrderManifold with serial transmission kit Plug-in type• Solenoid valve wiring process reduced
considerably.
1209
Series VFS50005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
1-2-16-VFS1000.qxd 09.8.3 5:06 PM Page 5
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Formula for manifold weight M = 0.811n + 1.231 (kg) n: StationStations
L
L1
L2
2194212
3245263
4296314
5347365
6398416
7449467
8500518
9551569
10602620
FormulaL1 = 51 x n + 92L2 = 51 x n + 110
Manifold — Plug-in type, Non plug-in type
Non plug-in type: VV5FS5-10- Station 1- Port size
Formula for manifold weight M = 0.911n + 1.621 (kg) n: Station3 4( ): 2(B)/4(A) port Rc
3 4( ): 2(B)/4(A) port Rc
Plug-in type (With terminal block): VV5FS5-01T- Station 1- Port size
Bottom ported:VV5FS5-01T- Station 2- Port size
DIN terminalVV5FS5-10- Station 2- Port size
Direct manual override
Pilot valvemanual override
Direct manual override
Pilot valvemanual override
Applicable cabtire cable O.D.ø8 to ø10
Stations
Pitc
hP
= 5
1P
itch
P =
51
Stations
Electrical entry
(External pilot)
(Pilot EXH)
U side
U side
D side
D side
(External pilot)
(Pilot EXH)
(External pilot)
(Pilot EXH)
1210
Series VFS5000
P1111-P1228-E.qxd 08.9.2 2:55 PM Page 1210
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
StationsL
L1
L2
2194212
3245263
4296314
5347365
6398416
7449467
8500518
FormulaL1 = 51 x n + 92L2 = 51 x n + 110
Manifold — Plug-in type with multi-connector/D-sub connector
Plug-in type with multi-connector: VV5FS5-01CD- Station 1- Port size , VV5FS5-01CU- Station 1- Port size
Plug-in type with D-sub connector: VV5FS5-01FD- Station 1- Port size , VV5FS5-01FU- Station 1- Port size
Bottom ported: VV5FS5-01 - Station 2- Port sizeCD
CU
Formula for manifold weight M = 0.916n + 1.709 (kg) n: Station ∗ Refer to page 1227. For wiring specifications.
Bottom ported:VV5FS5-01 - Station 2- Port sizeFD
FU
Formula for manifold weight M = 0.916n + 1.633 (kg) n: Station ∗ Refer to page 1227. For wiring specifications.
U side
D side
U side
D side
Direct manual override
Pilot valvemanual override
Plug assembly VVFS2000-30A-�(Option: Refer to page 1227.)
Pilot valve manual override
Direct manual override
Plug assembly VVZS3000-21A-�(Option: Refer to page 1227.)
Stations
Stations
(External pilot)
(External pilot)
Pitc
hP
= 5
1P
itch
P =
51
( ): 2(B)/4(A) port Rc 3 4
( ): 2(B)/4(A) port Rc 3 4
(Pilot EXH)
(Pilot EXH)
1211
Series VFS50005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:56 PM Page 1211
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Manifold Specifications
Manifold with Exhaust Cleaner
Plug-in type
Non plug-in type
CautionWhen using an exhaust cleaner, mount it downwards.
∗ Refer to Best Pneumatics Vol. 6 for Exhaust Cleaner details.
How to Order
Exhaust cleaner(Option)
Exhaust cleaner(Option)
10610 04 CDSeries VFS5000
Manifold
VV5FS5
Base type/Electrical entry
01T
01C
01F
10
Symbol
CDCU
D sideU side
Exhaust cleanermounting direction
D side mountingU side mounting
Exhaust cleanermounting direction
∗ Option
Thread type
Port sizeSymbol0406
A, BP
M
• Serves to protect working environment.
• Valve exhaust noise dampening: 35 dB or more.
• Collection rate of drainage and oil mist: 99.9% or more.
• Piping work is reduced.
Connector mounting direction
Stations
Manifold
Wiring
Applicable valve model
Porting specificationsRc
Stations
Plug-in type: VV5FS5-01� Non plug-in type: VV5FS5-10
With terminal blocksWith multi-connectorWith D-sub connector
DIN terminal Grommet terminal
VFS5�00-�F VFS5�10-�D, VFS5�10-�ECommon SUP/Common EXH
Side: 1/2, 3/4, Bottom: 1/2 (Option)
2 to 10 (1)
Applicable exhaust cleaners AMC810-14 (Connecting port size R 1 1/2) (2)
P: 3/4, EXH: 1 1/2
Note 1) With multi-connector, or with D-sub connector: 8 stations max.Note 2) Exhaust cleaner: Not attached.
2(B), 4(A) port1(P), 3(R2), 5(R1)
U side
D side
∗ For bottom ported, Rc is only available.
Symbol
VV5FS5-10-061-04-CUVFS5110-5EVFS5210-5EVVFS5000-10AAMC810-14
Plug-in typewith terminal block
Plug-in typewith multi-connector
Plug-in typewith D-sub connector
Non plug-in type
Symbol Applicable base
DNil
U01C, 01F
01T, 10With connector
D side mountingNone
U side mounting
2 stations
10 stations
02
10
Base type 01T, 10: 2 to 10 stationsBase type 01C, 01F: 2 to 8 stations
··· ···
NilN∗
RcNPT
NPTFG
T∗
F∗
RcRc Rc Mixed
3 43 4
1 2
1 2
Symbol
1 Side
2 Bottom∗
Passage
R1, R2P
CommonCommon
∗ Option
Portingspecifications
(A, B)
<Example> • Plug-in type with terminal block (6 stations)
(Manifold base)(2 position single)(2 position double)(Blanking plate)(Exhaust cleaner)
• Non plug-in type (6 stations)
13211
VV5FS5-01T-061-04-CDVFS5100-5FZVFS5200-5FZVVFS5000-10AAMC810-14
(Manifold base)(2 position single)(2 position double)(Blanking plate)(Exhaust cleaner)
13211
How to Order Manifold Assembly [Example]Add the valve and option part numbers in order starting from the first station on the D side.
∗ ∗ ∗
∗ ∗ ∗
The asterisk denotes the symbol for assembly. Prefix it to the part numbers of the solenoid valve.
Q
CE-compliantNil —
CE-compliant
1212
Series VFS5000
1-02-16-VFS1000.qxd 09.11.2 1:31 PM Page 23
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Manifold with Exhaust Cleaner — Plug-in type, Non plug-in type
D side mounting
U side mounting
D side mounting
U side mounting
StationsL
L1
L2
2194212
3245263
4296314
5347365
6398416
7449467
8500518
9551569
10602620
FormulaL1 = 51 x n + 92L2 = 51 x n + 110
n: Stations
Plug-in type: VV5FS5-01T- Station 1- Port size -CDCU
Non plug-in type: VV5FS5-10- Station 1- Port size - CDCU
( ): 2(B)/4(A) port Rc 3/4
( ): 2(B)/4(A) port Rc 3/4
Direct manualoverride
Pilot valvemanual override
Direct manualoverride
Pilot valvemanual override
Stations
Stations
Electrical entry
Exhaust cleaner(Option)
U side
U side
D side
U side
D side
D side
U side
D side
Exhaust cleaner(Option)
≅
1213
Series VFS50005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:56 PM Page 1213
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
VV5FS5 X19901SPlug-in type
Serial transmission kit
Stations2
10
2 stations
10 stationsNote 1) Max. 10 stations. Add 1 station for serial unit mounting.Note 2) Max. 10 Stations: For single and double mixed wiring. (No. of
valves: 9) Max. 9 stations: For standard double wiring (No. of valves: 8)
Port sizeSymbol
0406M
A, BP, R1, R2
Rc 3/4
∗ For bottom ported: Rc 1/8 only
Rc 1/2Rc 3/4Mixed
SI unit mounting positionDU
D side mountingU side mounting
Applicable models
For U side mouning For D side mouning—
EX123U-SUW1EX123U-SUH1EX123U-SSL1EX123U-SSL2EX124U-SDN1EX124U-SCS1EX124U-SCS2EX124U-SMJ1
—EX123D-SUW1EX123D-SUH1EX123D-SSL1EX123D-SSL2EX124D-SDN1EX124D-SCS1EX124D-SCS2EX124D-SMJ1
DescriptionSI unit part no.
Without SI unitNKE Corporation: Uni-wire System (16 outputs)NKE Corporation: Uni-wire H System (16 outputs)SUNX Corporation: S-LINK System (16 outputs)SUNX Corporation: S-LINK System (8 outputs)DevieNet (2 power supply systems)OMRON Corporation: CompoBus/S (16 outputs) (2 power supply systems)OMRON Corporation: CompoBus/S (8 outputs) (2 power supply systems) CC-Link (2 power supply systems)
Symbol
0F1HJ1J2QR1R2V
� Correspondence of SI unit output numbers and solenoid valve coils<Wiring Example 1> Double wiring (Standard)
D side
Dou
ble
Dou
ble
Sin
gle
Sin
gle
Sin
gle
Dou
ble
Sin
gle
Sin
gle
SI u
nit
1
A B
2
A B
3
A B
4
A B
5
A B
6
A B
7
A B
8
A B
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
9
SI u
nit o
utpu
t no.
U side
<Wiring Example 2> Single/Double mixed wiring (Option)
∗ Mixed wiring is available as an option. Use the manifold specification sheet to specify this.
VFS5 00 5 F
24 VDC
Nil Internal pilotExternal pilot
Pilot type
R
Nil Non-locking push type (Flush)Non-locking push type (Extended)
Locking type (Tool required)Locking type (Lever)
Pilot valve manual override
ABC
Nil NoneWith light/surge voltage suppressor
Option
Z
Nil NoneCoil rated voltage
D side
Dou
ble
Dou
ble
Sin
gle
Sin
gle
Sin
gle
Dou
ble
Sin
gle
Dou
ble
Sin
gle
SI u
nit
1
A B
2
A B
3
A
4
A
5
A
6
A B
7
A
8
A B
9
A
10
0 1 2 3 7 84 5 9 116
SI u
nit o
utpu
t no.
U side
10 11
How to Order Valves
Symbol123456
2 position single2 position double
3 position closed center3 position exhaust center3 position pressure center3 position double check
How to Order Manifold
Refer to pages 1653 to 1655 for the details of the EX123/124 integrated type (for output) serial transmission system.
0408 1VU
Made to OrderSerial Transmission Kit Manifold: EX123/124 Integrated Type (For Output) Serial Transmission System
How to Order
Nil RcNPT
NPTFG
Thread type
NTF
SI unit can be mounted oneither U or D side.
Combination symbol
Symbol
SideBottom
Port specification
P R1, R2
Pipingspecification
A, B
CommonCommon12∗
∗ Option
1214
P1111-P1228-E.qxd 08.9.2 2:56 PM Page 1214
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Serial Transmission Kit Manifold: EX123/124 Integrated Type (For Output) Serial Transmission System
VV5FS5-01S Mounting position Model - Stations Symbol - Port size Thread -X199
DimensionsFormula L1 = 51n + 92 L2 = 51n + 110
n: Stations (Max. 10 stations)
LL1
L2
n 2194212
3245263
4296314
5347365
6398416
7449467
8500518
9551569
10602620
Note) Actual number of manifold base stations: Add 1 SI unit mounting station to the number of valve stations.
∗ Use a dripproof plug assembly (AXT100-B04A) for the unused conduit port (G 1/2).
( ): 2(B)/4(B) port Rc 3/4
1 2 3 4 5 6 7 nStationsD side U side
A
B
A
B
A
B
SMC
A
B
A
B
A
B
A
B
48.5
5180.5
167
132
179
91
20
3(1)3(1)
70(7
1.5)
24(2
3)
Manual override
4(A), 2(B) port2n x Rc 1/2, 3/4
SMC
B
A
SMC
SMC
SERIAL U
NIT
24V0V
+24V24G
DA
DB
DG
FG
B RATE
PW
STATION NO.
LERR.RD
SD
LRUN
MO
DE
LS
V(SI No.EX124U-SMJ1)
SMC
B
A
SMC
SMC
B
A
SMC
SMC
B
A
SMC
B
A
SMC
L2
L1
244
240
200
223
207 17
4.5
103.
511
1.5
6060
R5.5 11
SMC
PE
PE
EB
PE
A
67
81
31
50
7210
3
6143
3737
1(P), 5(R1), 3(R2) port6 x Rc 3/4
(External pilot port)2 x Rc 1/8
(Pilot EXH port: PE)4 x Rc 1/8
Electrical entry2 x G 1 1/4
SI unit
EX124�: 4 x G 1/2
Electrical entry
EX123�: 2 x G 1/2
1215
Series VFS50005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:56 PM Page 1215
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Manifold Option Parts — Plug-in type, Non plug-in type
Individual SUP spacer:VVFS5000-P-04-1 (Plug-in type)VVFS5000-P-04-2 (Non plug-in type)
Individual EXH spacer:VVFS5000-R-04-1 (Plug-in type)VVFS5000-R-04-2 (Non plug-in type)
SUP block plate: AXT628-12AEXH block plate: AXT512-14-1A
Throttle valve spacer:VVFS5000-20A-1 (Plug-in type)VVFS5000-20A-2 (Non plug-in type)
Interface regulator/A port regulation:ARBF5050-00-A-1 (Plug-in type)ARBF5050-00-A-2 (Non plug-in type)
Interface regulator/B port regulation:ARBF5050-00-B-1 (Plug-in type)ARBF5050-00-B-2 (Non plug-in type)
Double check spacer:VVFS5000-22A-1 (Plug-in type)VVFS5000-22A-2 (Non plug-in type)
Interface regulator/P port regulation:ARBF5050-00-P-1 (Plug-in type)ARBF5050-00-P-2 (Non plug-in type)
IndividualSUPspacer
IndividualEXHspacer
Double checkspacer
Interfaceregulator
Interfaceregulator
Interfaceregulator
Block platemounting position
Throttle valvespacer
( ) : SUP block plate
1216
Series VFS5000
P1111-P1228-E.qxd 08.9.2 2:56 PM Page 1216
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Replacement Parts
Replacement Parts: Sub Assembly
No.12345678
9
13
Description MaterialSteel plateSteel plate
NBRNBRNBRNBRNBR—
For 01TFor 01SU
NBR
Part no.
No.
10
Description Assembly part no.
Component parts
11
Applicable manifold base
12
Manifold Base Construction — Plug-in type, Non plug-in type
• For increasing the manifold bases, please order the manifold block assembly number of the principal part assembly !0.For plug-in type: The manifold base with terminal stand (integrated with a junction cover) is required with the o junction cover assembly.
Connection fitting AConnection fitting BO-ringO-ringO-ringO-ringO-ringTerminal assembly
Junction cover assembly
Rubber plug
AXT628-6-1AAXT628-6-2AS568-006AS568-010AS568-013AS568-022AS568-026
AXT628-5-1AVVFS5000-4A-
AZ738-31A- AXT336-9
VVFS5000-1A-2-
VVFS5000-1A-1-
VVFS5000-2A-1VVFS5000-2A-2
Manifold block !0, Metal joint q, w,Terminal i, O-ring e, r, t, y, u, Receptacle assembly
Plug-in type
Manifold block !0, Metal joint q, w, O-ring e, r, t, y, u Non plug-in typeEnd plate (U) !1, Metal joint q, wEnd plate (U) !1, Metal joint q, w
End plate (D) !2, Metal joint q, w, O-ring e, r, t, y, uEnd plate (D) !2, Metal joint q, w, O-ring e, r, t, y, u
Plug-in typeNon plug-in type
VVFS5000-3A-1
Manifold block assembly
End plate (U side) assembly
End plate (D side) assemblyPlug-in type
Non plug-in typeVVFS5000-3A-2
0406
0406
Stations
Stations
End plate (D side)
Manifold block
End plate (U side)
Note) Manifold Base/Construction: Plug-in type with terminal block.
1217
Series VFS50005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:56 PM Page 1217
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
JIS Symbol2 position
Single
Double
Standard Specifications
Model
Compact yet provides a large flow capacity3/4: C: 38 dm3/(s·bar)
Low power consumption: 1.8 W DC
Easy maintenance2 types of sub-plates: Plug-in and non plug-in
Option Specifications
Type of actuation
Single
Double
Model
Plug-in Non plug-in
VFS6100
VFS6200
VFS6110 29
29
0.10
0.10
6.8
6.8
38
38
0.10
0.10
9.0
9.0VFS6210
PortsizeRc
3 4
3 4
180
180
2.5
2.75
160 or less
60 or less
Note 1) Based on JIS B 8375-1981 (once per 30 days) for the min. operating frequency.Note 2) According to JIS B 8375-1981. (The value at supply pressure 0.5 MPa.)Note 3) The figures in the above list are for without sub-plate. In case of with sub-plate, add 1.65 kg for Rc 3/4 and 1.5 kg for RC 1 respectively.Note 4) “Note 1)” and “Note 2)” are with controlled clean air.Note 5) The flow characteristics is for the port size Rc 4/3.
C[dm3/(s·bar)] b Cv
C[dm3/(s·bar)] b Cv
1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) Flow characteristics
1
1
Fluid Air/Inert gasMaximum operating pressureMinimum operating pressure
1.0 MPa0.1 MPa
–10 to 60°C (1)
Non-lube (2)
Non-locking push type (Flush)150/50 m/s2 (3)
Type E: Dustproof (Level 0), Type F: Dripproof (Level 2), Type D: Splashproof (Level 4) (4)
100, 200 VAC, 50/60 Hz; 24 VDC–15 to +10% of rated voltage
5.6 VA/50 Hz, 5.0 VA/60 Hz3.4 VA (2.1 W)/50 Hz, 2.3 VA (1.5 W)/60 Hz
InrushHolding
Conduit terminalGrommet terminal, DIN terminal
Plug-in typeNon plug-in type
Ambient and fluid temperature1.5 MPaProof pressure
LubricationPilot valve manual overrideShock/Vibration resistance EnclosureCoil rated voltageAllowable voltage fluctuation
Class B or equivalent (130°C) (5)Coil insulation typeApparent power(Power consumption)
Electrical entry
1.8 W (2.04 W: With light/surge voltage suppressor)Power consumption DC
Note 1) Use dry air at low temperatures.Note 2) Use turbine oil Class 1 (ISO VG32), if lubricated.Note 3) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial
direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period)
Note 4) Based on JIS C 0920. Note 5) Based on JIS C 4003.
Val
ve s
pec
ific
atio
ns
Elec
tric
ity s
peci
ficat
ions
AC
Manual override Main valve
Coil rated voltage
Option
110 to 120, 220, 240 VAC (50 Hz/60 Hz)Direct manual override
Pilot type External pilot
12, 100 VDC
Note) Operating pressure: 0 to 1.0 MPaPilot pressure: 0.1 to 1.0 MPa
Porting specifications Bottom portedWith light/surge voltage suppressor, Non-rotating DIN terminal
Note)
2 po
sitio
n
Max. operating
cycle(cpm)
Responsetime(ms)
(Details → P. 1222-5)
Mass(kg)
(1)(2)
(3)
1218
5 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
Series VFS6000
VFS.qxd 10.11.25 9:49 AM Page 10
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
How to Order Pilot Valve Assembly
1 10FVFS6 5
DVFS6
Symbol
1
2 position single
2
2 position double
O: Plug-in type sub-plate
1: Non plug-in type sub-plate
Body type
Portingspecifications
Nil Side ported
Port sizeNil06
Without sub-plate
10
Thread typeNilN∗ NPT
Rc
T∗ NPTFF∗ G
∗ Option
Pilot typeNilR∗
Internal pilotExternal pilot
∗ Option
Body Option01∗
StandardDirect manual override
∗ Option
Coil rated voltage
∗ Option
10
0
1
0
5
Body type
OptionNilZ
F: Plug-in typeconduit terminal
Electrical entry
E: Grommet terminal D: DIN terminal
Electrical entry
1 0
Z
Z
Coil rated voltage
SF4 F1 22
How to Order
Plug-in
Non plug-in
RcRc 1
3 4
∗ Option
123∗4∗56∗7∗
100 VAC, 50/60 Hz200 VAC, 50/60 Hz
110 to 120 VAC, 50/60 Hz220 VAC, 50/60 Hz
24 VDC12 VDC
240 VAC, 50/60 Hz9∗ Other
NoneWith light/surge voltage suppressor
1 100 VAC, 50/60 Hz2 200 VAC, 50/60 Hz3∗ 110 to 120 VAC, 50/60 Hz4∗ 220 VAC, 50/60 Hz5 24 VDC6∗ 12 VDC7∗ 240 VAC, 50/60 Hz9∗ Other
∗ Refer to page 1224 for voltage conversion.
Q
CE-compliantNil —
CE-compliant
1219
Series VFS60005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
1-02-16-VFS1000.qxd 09.11.2 1:31 PM Page 24
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Cylinder Speed Chart
Series
VFS6100-10
800700600500400300200100 0
Bore size
ø125 ø140 ø160 ø180 ø200 ø250 ø300
Series CS1/CS2SGP25A x 1 m
AS600-10AN600-10
Tube bore x LengthSpeed controllerSilencer
VFS6100-10
Conditions
Construction
Sub-plate Assembly Part No.
2 position single 2 position double
Plug-in
Non plug-in
∗ Mounting bolt and gasket are not included.
Component PartsNo.
23
1Description Material Note
456789101112
Aluminum die-castedStainless steel
Aluminum die-casted
Aluminum die-casted—
Platinum silverPlatinum silver
BlackAluminum die-casted Black
Resin —Resin —
——
Resin
Sub-plateBody
Spool/SleeveAdapter plateEnd platePistonJunction coverLight cover —
————
NBRStainless steelReturn spring
GasketDetent assemblyPilot valve assembly
∗ Refer to “How to Order Pilot Valve Assembly” on page 1219.
VFS6000-P-
VFS6000-S-
0610
0610
Series CS1/CS2Pressure 0.5 MPaLoad factor 50%Stroke 300 mm
Use as a guide for selection.Please confirm the actual conditions with SMC Sizing Program.
∗ It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open.
∗ The average velocity of the cylinder is what the stroke is divided by the total stroke time.∗ Load factor: ((Load weight x 9.8)/Theoretical force) x 100%
Averagespeed(mm/s)
Perpendicular,upward actuationHorizontalactuation
Plug-in
Non plug-in
Sub-plate Assembly (For External Pilot) Part No.
Part no. for mounting bolt and gasketBG-VFS6000
VFS6000-P-R
VFS6000-S-R
0102
0102
1220
Series VFS6000
P1111-P1228-E.qxd 08.9.2 2:56 PM Page 1220
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Plug-in — 2 Position single/Double
2 position single: VFS6100-�F
2 position double: VFS6200-�F
Pilot valve manual override
Pilot valve manual override
4 x ø9 mounting hole
4 x ø9 mounting hole
Solenoid valve mounting bolt(Hexagon socket head cap screw)
Light window (�FZ)
G 1/2 electrical entry
2 x Rc 1/8 pilot EXH port
G 1/2 electrical entry
2 x Rc 1/8 pilot EXH port
Rc 1/8 external pilot port
(VFS6100R)
Rc 1/8 external pilot port(VFS6200R)
(A, B
por
t)(A
, B p
ort)
Light window (�FZ)
4 x M8 x 80 with SW
with SW
Solenoid valve mounting bolt(Hexagon socket head cap screw)
1221
Series VFS60005 Port Pilot Operated Solenoid ValveMetal Seal, Plug-in/Non Plug-in
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:56 PM Page 1221
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Non Plug-in — 2 Position single/Double
2 position single: VFS6110-�E, VFS6110-�D
2 position double: VFS6210-�E, VFS6210-�D
Light window (�EZ, �DZ)
Pilot valve manual override
Pilot valve manual override
Light window (�EZ, �DZ)
(VFS6210R)
Rc 1/8 external pilot port
4 x ø9 mounting holeSolenoid valve mounting bolt(Hexagon socket head cap screw)
Applicable cabtire cable O.D.ø8 to ø10
Applicable cabtire cable O.D.
ø8 to ø10
2 x Rc 1/8 pilot EXH port
2 x Rc 1/8 pilot EXH port
external pilot port(VFS6110R)
(A, B
por
t)(A
, B p
ort)
4 x M8 x 80 with SW
Solenoid valve mounting bolt(Hexagon socket head cap screw)
4 x M8 x 80 with SW
4 x ø9 mounting hole
1222
Series VFS6000
P1111-P1228-E.qxd 08.9.2 2:56 PM Page 1222
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 110VFS2
Symbol
1
2 position single
2
2 position double
3
3 position closed center
4
3 position exhaust center
5
3 position pressure center
6
3 position double check
Porting specificationsNilB∗
Side portedBottom ported
OptionNilZ
NoneWith light/surge voltage suppressor
Thread typeRcNPT
NPTFG
NilN∗T∗F∗
∗ Option
∗ Option
Coil rated voltage123∗4∗56∗
100 VAC, 50/60 Hz200 VAC, 50/60 Hz
110 to 120 VAC, 50/60 Hz220 VAC, 50/60 Hz
24 VDC12 VDC
7∗ 240 VAC, 50/60 H
Body type
Pilot type
∗ Option
∗ Combining double check spacer with external pilot will not work.
Electrical entry
1: Non plug-in typesub-plate
Nil: Non-locking push type(Flush)
B∗: Locking type(Tool required)
A∗: Non-locking push type(Extended)
C∗: Locking type(Lever)
D: DIN terminal
∗ Option
Pilot valve manual override
NilR∗
Internal pilotExternal pilot
02Non plug-in 2
Port sizeNil
01Rc Non plug-in type,
Standardtype
Without sub-plate
1 8
1 402
Rc
∗ Option: External pilot is possible only to the one with sub-plate.
Conforming toCSA standard
30
Refer to standard products for specifications and dimensions.
How to Order
∗
1222-1
5 Port Pilot Operated Solenoid ValveMetal Seal, Non Plug-in
Series VFS2000
VFS.qxd 10.11.25 9:49 AM Page 11
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
DNon plug-in VFS330
Symbol
1
2 position single
2
2 position double
3
3 position closed center
4
3 position exhaust center
∗ Reverse pressure: Can be used by external pilot specifications.
5
3 position pressure center
6
3 position double check
1: Non plug-in type sub-plate
Pilot valvemanual override
Porting specificationsNilB∗
Side portedBottom ported
∗ Option
Port sizeNil02
Without sub-plateRc
03 Rc
Thread typeNilN∗ NPT
Rc
T∗ NPTFF∗ G
∗ Option
1 43 8
Pilot typeNilR∗
Internal pilotExternal pilot
∗ Option
Body option01∗
StandardDirect manual override
∗ Option
Coil rated voltage123∗4∗56∗7∗
100 VAC, 50/60 Hz200 VAC, 50/60 Hz
110 to 120 VAC, 50/60 Hz220 VAC, 50/60 Hz
24 VDC12 VDC
240 VAC, 50/60 Hz
∗ Option
∗ Option
Nil: Non-locking push type(Flush)
022
Body type
OptionNilZ
NoneWith light/surge voltage suppressor
A∗: Non-locking push type(Extended)
B∗: Locking type (Tool required)
C∗: Locking type(Lever)
D: DIN terminal
Electrical entry
2 1 1
Refer to standard products for specifications and dimensions.
Conforming toCSA standard
How to Order
1 4∗ For bottom ported, Rcis only available.
1222-2
5 Port Pilot Operated Solenoid ValveMetal Seal, Non Plug-in
Series VFS3000
VFS.qxd 10.11.25 9:49 AM Page 12
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 DVFS4
Symbol
1
2 position single
2
2 position double
3
3 position closed center
4
3 position exhaust center
∗ Reverse pressure: Can be used by external pilot specifications.
5
3 position pressure center
6
3 position double check
1: Non plug-in type sub-plate
Pilot valvemanual override
Porting specificationsNilB∗
Side portedBottom ported
Port sizeNil Without sub-plate
Rc0304∗ Rc
∗ EA, EB: Rc
Thread typeNilN∗ NPT
Rc
T∗ NPTFF∗ G
∗ Option
3 8
3 8
1 2
Pilot typeNilR∗
Internal pilotExternal pilot
∗ Option
Body option01∗
StandardDirect manual override
∗ Option
Coil rated voltage123∗4∗56∗7∗
100 VAC, 50/60 Hz200 VAC, 50/60 Hz
110 to 120 VAC, 50/60 Hz220 VAC, 50/60 Hz
24 VDC12 VDC
240 VAC, 50/60 Hz∗ Option
∗ Option
Nil: Non-locking push type(Flush)
031 1 1
Body type
OptionNilZ
NoneWith light/surge voltage suppressor
A∗: Non-locking push type(Extended)
B∗: Locking type (Tool required)
C∗: Locking type(Lever)
D: DIN terminal
Electrical entry
2 0
∗ In the case of external pilot (Option), bottom piping is not available.
Refer to standard products for specifications and dimensions.
30
Conforming toCSA standard
Non plug-in
How to Order
1222-3
5 Port Pilot Operated Solenoid ValveMetal Seal, Non Plug-in
Series VFS4000
VFS.qxd 10.11.25 9:49 AM Page 13
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
DNon plug-in VFS5
Symbol
1
2 position single
2
2 position double
3
3 position closed center
4
3 position exhaust center
5
3 position pressure center
6
3 position double check
1: Non plug-in type sub-plate
Pilot valvemanual override
Port sizeNil03
Without sub-plateRc
04 Rc
Thread typeNilN∗ NPT
Rc
T∗ NPTFF∗ G
∗ Option
3 81 2
06 Rc 3 4
Pilot typeNilR∗
Internal pilotExternal pilot
∗ Option
Body option01∗
StandardDirect manual override
∗ Option
Coil rated voltage123∗4∗56∗7∗
100 VAC, 50/60 Hz200 VAC, 50/60 Hz
110 to 120 VAC, 50/60 Hz220 VAC, 50/60 Hz
24 VDC12 VDC
240 VAC, 50/60 Hz∗ Option
∗ Option
Nil: Non-locking push type(Flush)
061 5
Body type
OptionNilZ
NoneWith light/surge voltage suppressor
A∗: Non-locking push type(Extended)
B∗: Locking type (Tool required)
C∗: Locking type(Lever)
D: DIN terminal
Electrical entry
1 0
Porting specificationsNilB∗
Side portedBottom ported
∗ In the case of external pilot (Option), bottom piping is not available.
30
Conforming toCSA standard
Refer to standard products for specifications and dimensions.
How to Order
1222-4
5 Port Pilot Operated Solenoid ValveMetal Seal, Non Plug-in
Series VFS5000
VFS.qxd 10.11.25 9:49 AM Page 14
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
DNon plug-in VFS6
Symbol
1
2 position single
2
2 position double
1: Non plug-in type sub-plate
Porting specificationsNil Side ported
Port sizeNil06
Without sub-plate
10 Rc 1
Thread typeNilN∗ NPT
Rc
T∗ NPTFF∗ G
∗ Option
Rc 3 4
Pilot typeNilR∗
Internal pilotExternal pilot
∗ Option
Body option01∗
StandardDirect manual override
∗ OptionCoil rated voltage123∗4∗56∗7∗
100 VAC, 50/60 Hz200 VAC, 50/60 Hz
110 to 120 VAC, 50/60 Hz220 VAC, 50/60 Hz
24 VDC12 VDC
240 VAC, 50/60 Hz
∗ Option
101 5
Body type OptionNilZ
NoneWith light/surge voltage suppressor
D: DIN terminal
Electrical entry
1 0 Z
Refer to standard products for specifications and dimensions.
30Conforming toCSA standard
How to Order
1222-5
5 Port Pilot Operated Solenoid ValveMetal Seal, Non Plug-in
Series VFS6000
VFS.qxd 10.11.25 9:49 AM Page 15
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Light/Surge Voltage Suppressor, Electrical Entry Single unit
Series VFS1000/2000/3000Body Ported
Base Mounted Series VFS2000
Light/Surge Voltage Suppressor
Caution
Light/Surge Voltage SuppressorAC and 100 VDC
24 VDC or less
In the case of DIN terminal and terminal block (with indicator light/surge voltage suppressor), the interior wiring is shown below.
Note) There is no polarity.
To change direction of DIN terminal retaining screw, pull off outer cover, rotate connector board through 180°. Replace cover and tighten screw.
Loosen the set screw (M3–2 pcs.), take out pilot operator, turn solenoid valve 180° degrees to change the direction of lead wire and manual override. (Possible on Series VFS1000 only.)
Single
Double
Single
Double
Applicable terminal: 1.25-3, 1.25-3S, 1.25Y-3N, 1.25Y-3S, but in the case of with DIN terminal block, is not a terminal structure.
Surge voltage suppressorDC AC
Manual position
Wiring
Changing Direction of DIN Terminal/Cable Entry
Changing Direction of Electrical Entry and Manual Override
With DINterminal block
With terminal block
• Type G: Lead wire comes directly from the solenoid part. Connect it with the power source. Grommet with DC voltage surge voltage suppressor has polarity. Connect red lead wire to + (positive) side and black to – (negative) side.
Terminal no. 1 +(–) A side
Terminal no. 1 +(–)
With indicator light
Terminal no. 2 –(+)Note) There is no polarity (+, –).
Terminal no. 2 –(+)Note) There is no polarity (+, –).
B side Terminal no. 1 +(–)
With indicator lightTerminal no. 2 –(+)
With indicator light
Terminal no. 1 (+)
B side Terminal no. 1 (+)Terminal no. 2 (–)
Terminal no. 2 (–) Terminal no. 2 (–)
With indicator light
With indicator lightA side
Red +
Black –
Varistor
• In the case of surge voltage suppressor, surge voltage absorption device ZNR is attached to AC power.
24 VDC or less
Plug-in type Non plug-in type
Single
Double
Double
• Type G: Use lead wire from solenoid to connect with power side.Grommet with DC voltage surge voltage suppressor has polarity. Connect red lead wire to + (positive) side and black to – (negative) side.
Surge voltage suppressorDC AC
Single
How to Exchange
AC and 100 VDC
Solenoid valve• Loosen 3 set screws (hexagonal socket head
cap screw M3 x 31) and pull solenoid valve out vertically, otherwise it may cause damage to the solenoid valve. Never remove a valve at an angle.
• When mounting solenoid valve onto the base, plug pin assembly (base side) into receptacle assembly (body-side) vertically.
Lead wire, red
Black
Black
B side lead wire, brown
White
Red A side
With indicator light
With light/surgevoltage suppressor
Terminal no. 1 +(–) A side
Terminal no. 1 +(–)
Terminal no. 2 –(+)
B side terminal no. 1 +(–)
Note) There is no polarity (+, –).
Terminal no. 2 –(+)Note) There is no polarity (+, –).
With indicator light
Receptacle assembly
Terminal no. 2 –(+)
With light/surgevoltage suppressor
With indicator light
With indicator light
With indicator light
Red +
Black –
Varistor
Exchange of pilot valve (Voltage exchange)• When changing rated voltage and electrical
entry etc., pilot valve assembly can be changed. But in case of a plug-in type with light/surge voltage suppressor, pilot valve assembly cannot be changed for changing rated voltage.
• Change of the electrical entry of DIN type connector cableUnscrew retaining screw, pull off outer cover, rotate connector board through 180°. Replace cover and tighten screw. Applicable cable: O.D. ø6 to ø8.
Single unit/Plug-in type sub-plate: TConduit terminal (With terminal block)• If the junction cover (1) of the sub-plate is
removed, you can see the plug-in type terminal block (2) (part no. NVF2000-27A-1) mounted inside the sub-plate.The following markings are on the terminal block board. Connect with corresponding power side.
DescriptionTerminal block
marking
Solenoid A side Solenoid B side
A B
Applicable terminal: 1.25-3, 1.25-3S, 1.25Y-3N,1.25Y-3S, but in the case of with DIN connector board, is not a terminal structure.Tightening torque for terminal: 0.6 N·m
Note) There is no polarity.
Changing Direction of DIN Terminal/Cable Entry
Electrical Connection
With DINterminal block
With terminal block
• There is no polarity.• When ground wiring and COM wiring are
required, please specify separately.• Applicable terminal: 1.25-3, 1.25-3S, 1.25Y-
3N, 1.25Y-3S
Single unit/Non plug-in type sub-plate: G, E, T, D• Type G: Use lead wire from solenoid to
connect with power side.• Type E, T, D: In the case of a DIN terminal
and terminal block (with light/surge voltage suppressor), the interior wiring is shown below. Connect with corresponding power side.
Pilot valve assembly
Pilot valve assembly
(1) (2)
Varistor
Varistor
Varistor Varistor
Varistor
Varistor
Varistor
Varistor Varistor
Varistor
VaristorVaristor
1223
Series VFSSpecific Product Precautions 1Be sure to read before handling.Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:56 PM Page 1223
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VFS3000/4000/5000/6000Base Mounted
Light/Surge Voltage Suppressor Substrate Part No.
VFS6000
Pilot cover
Mounting screw
Pilot valve assembly
VFS4000
VFS3000
VFS5000
VFS6000
VFS3000-10A-�100V or more24V or less100V or more24V or less100V or more24V or less
VF4000-9A-�VF4000-9B-�AXT627-7A-�AXT627-7B-�VF4000-9A-�VF4000-9B-�
-�: Coil rated voltage Symbol: Refer to below.1: 100 to 120 V2: 200 to 220 V5: 24 V
6: 12 V7: 240 V
Light/Surge Voltage Suppressor, Electrical Entry Single unit
Light/Surge Voltage Suppressor
How to Exchange
Lead Wire ConnectionIn the case of surge voltage suppressor, surge voltage absorption element is attached to terminal block on body area.
100 VAC/DC or more
24 VDC or less
SOL
SOL
Note) There is no polarity.
Light/Surge voltageabsorption element
With indicator light
With indicator light
Caution
VFS3000/4000/5000
Solenoid valve• Loosen set screw and take solenoid valve
out vertically, otherwise it may cause damage to the solenoid valve. Never remove a valve at an angle.
• When mounting solenoid valve onto the base, plug pin assembly (base side) into receptacle assembly (body side) vertically.
Pilot valve• When changing the rated voltage, electrical
entry, etc., pilot valve assembly can be ex-changed easily since this is plug-in type. Then, when changing the rated voltage with indicator light/surge voltage suppres-sor, change of indi-cator light/surge voltage suppressor substrate is also needed. So, order together with pilot valve assembly.
Plug-in type (With terminal)• If the junction cover (1) of the sub-plate is
removed, you can see the plug-in type terminal block (2) mounted inside the sub-plate.
DIN terminal block type• Male pin terminal of DIN terminal block
board of solenoid valve and wires as shown below. Connect to corresponding terminal block on the connector.
• There is no polarity.
DIN terminal (Wiring)
123
A sideB sideCOM
Ground
24 VDC or less
• Heavy-duty cordApplicable cable O. D.: ø8 to ø10
• Applicable terminalApplicable terminal on block board: 3 (kinds) 1.25Y-3L, 1.25-3.5S, 1.25-4M
• Connector/Clamping torqueSet screw 0.6 N·mTerminal screw 0.6 N·m
• Incorrect common (DIN terminal no. 3) causes damage on power side circuit.
Terminal blockmarking
Solenoid A side Solenoid B sideA B
+ – + –
• Applicable terminal:VFS3000: 1.25-3, 1.25-3S, 1.25Y-3N,
1.25Y-3SVFS4000: 1.25-3.5M, 1.25Y-3L, 1.25Y-3MVFS5000: 1.25-4, 1.25-4MVFS6000: 1.25-3.5M, 1.25Y-3L, 1.25-3M
• There is no polarity.• Tightening torque for terminal: 0.6 N·mNon plug-in type (With terminal)• Remove cover (1), over terminal block (2)
attached to the inside of body. Connect with corresponding power side. For a type with indicator light and surge voltage suppressor, pull out the light and surge voltage suppressor substrate (3) in a straight direction and then connect them.
• Applicable terminal:VFS3000: 1.25-3, 1.25-3S, 1.25Y-3N,
1.25Y-3SVFS4000/5000/6000: 1.25-3.5M,
1.25Y-3L, 1.25Y-3M
• There is no polarity.• Tightening torque for terminal: 0.6 N·m
Single
Double
Single
Double
100 VAC/DC or more
• The following markings are on the terminal block. Connect with corresponding power side.
(1)
(1)
(3)
(2)
(2)
A side
B side
B side
Ground
With indicator light
With indicator light
With indicator light
With indicator light
A side
A side B side
Varistor
Varistor
Varistor
VaristorVaristor
Varistor
Varistor Varistor
1224
Series VFSSpecific Product Precautions 2Be sure to read before handling.Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.
P1111-P1228-E.qxd 08.9.2 2:56 PM Page 1224
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Refer to front matters 44 to 47 for How to Calculate the Flow Rate.
Maintenance
How to Calculate the Flow Rate
1. A lot of carbon powder and oil waste from air sources (mostly from compressor) entering into the valve sometimes can lead to increased sliding resistance at the switching spool and cause valve malfunction. In the worst case, spool can adhere to the valve. Therefore, supply air should be kept clean.Also, if it is left for a long time exposed to an inferior quality of air under SUP pressure applied, carbon powders and oil wastes in the compressed air will be accumulated in the clearance of the spool and sleeve and can cause the spool to adhere to the valve.The remedy for this case is to check the compressor lubrication oil and find out the least oxidizing compressor lubrication oil.Meanwhile, a high filtration Mist Separator (Series AM) installed on the back of regular filter (Series AF) can prevent foreign particles from entering into the valve.Besides, as lubricant for compressors, Faircoal A-80 (Nippon Mitsubishi Oil Corp.), Dafney CSS55, CS49 (Idemitsu Kosan Co., Ltd), etc. are commercially available on the market.
2. When disassembling and re-assembling, please ensure that all components are in proper positions. Prevent gaskets from slipping, and clamp bolts down equally. Use torques listed below when mounting pilot valve assemblies and solenoid valve bodies.
Solenoid Valve Body
Holding screwM3
Proper tightening torque (N·m)0.45 to 0.6
Holding screwM3
Proper tightening torque (N·m)0.8 to 1.2
M4 1.4 to 2.5M5 2.8 to 5
Pilot Valve Assembly: SF4-�-�
Caution Interface Regulator SpecificationsInterface regulator (3)
Applicable solenoid valve seriesRegulating portProof pressureMaximum operating pressure
ARBF2000 ARBF3050 ARBF4050 ARBF5050VFS2000 VFS3000 VFS4000 VFS5000
P
M5 x 0.80.165.55.1
P → AP → B
1211
A → EAB → EB
0.4618.5224036
0.7231315545
0.833840
1112
2624
3231
2118.5
3531
4438
9077
A A AB B
Rc 1/8
BP P P
1.0 MPa1.5 MPa
Set pressure range (1) 0.1 to 0.83 MPa0.05 to 0.83 MPaAmbient and fluid temperature –5 to 60°C (No freezing)Port size for connection of pressure gaugeWeight (kg)Effective area at supply side (mm2) (2)
S at P1 = 0.7 MPa, P2 = 0.5 MPa
Effective area at exhaust side (mm2) (2)
S at P2 = 0.5 MPa
Note 1) Set within the operating pressure range of solenoid valve.Note 2) Synthesized effective area with solenoid valve 2 position single type.Note 3) • Operate an interface regulator only by applying pressure from the “P” port of the base, except
when using it as a reverse pressure valve. • To combine a pressure center valve and the A and B port pressure reduction of an interface
regulator, use the ARBF3000, 4000, or 5000 model.• To combine a reverse pressure valve and an interface regulator, use the ARBF3000, 4000, or 5000
model. Furthermore, the P port pressure reduction cannot be used for the reverse pressure valve.• When combining a double check valve and an interface regulator, use a manifold or sub-plate as a
basis, and stack them in the following order; the perfect spacer → the interface regulator → the valve.• When a closed center valve is combined with the interface regulator's A, B port regulation, note
that it cannot be used for intermediate stops of a cylinder because there is leakage from relief port on the regulator.
ARBF3050-00-P
ARBF2000-00-P
ARBF4050-00-P
ARBF5050-00-P
ARBF3050-00-A
ARBF4050-00-A
ARBF5050-00-A
P port regulation A port
regulation
B port regulation
JIS Symbol
Flow Characteristics (P → A) (Conditions: Inlet pressure 0.7 MPa. when 2 position solenoid valve is mounted.)
Inlet pressure 0.7 MPa
Inlet pressure 0.7 MPa Inlet pressure 0.7 MPa
Inlet pressure 0.7 MPa
Inlet pressure 0.7 MPa
Flow rate (l/min (ANR))
Out
let p
ress
ure
(MP
a)
Flow rate (l/min (ANR))
Out
let p
ress
ure
(MP
a)
Flow rate (l/min (ANR))
Out
let p
ress
ure
(MP
a)
Flow rate (l/min (ANR))
Out
let p
ress
ure
(MP
a)
Flow rate (l/min (ANR))
Out
let p
ress
ure
(MP
a)
Flow rate (l/min (ANR))
Out
let p
ress
ure
(MP
a)
Flow rate (l/min (ANR))
Out
let p
ress
ure
(MP
a)
1225
Series VFSSpecific Product Precautions 3Be sure to read before handling.Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
P1111-P1228-E.qxd 08.9.2 2:56 PM Page 1225
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Lead Wire Connection Manifold/Plug-in
Type 01 Insert Plug with Lead Wire Type 01 with Terminal Block
Series VFS2000 (Insert plug with lead wire is not available for Series VF3000, 4000, and 5000.) Series VFS2000
Series VFS3000
Series VFS4000/5000
Caution
How to remove junction cover (Type 01)Turn the knob (2) of junction cover (1) on the manifold block side by hand or slotted screwdriver to the C → O direction (counterclockwise) 90°. While holding the knob and upper part of junction cover, pull outward to remove junction cover.When reassembling, do the opposite.
How to Use Insert Plug• When removing insert plug (1) from
manifold base, push the lever area (2) of inset plug downward with thumb and pull it together with the lead wire (3) outward.
WiringThe insert plug (1) is attached to the manifold block and lead wire is plugged in with valve side as shown in the following list.
Single solenoid: AXT624-52A-S-1Double solenoid: AXT624-52A-D-1
Connect with corresponding power side.
Power supply Valve modelSingle solenoidAC
DC Double solenoid
Solenoid ARed, BlackRed, Black
Solenoid B—
Brown, White∗ There is no polarity.∗ Lead wire length is 1 m.
• When placing the inset plug (1) into the manifold base, push the lever area of inset plug with thumb and plug it in its place in the receptacle housing (4) horizontally.After plugging, pull lead wire out a little bit to ensure that insert plug is secure.
( (
(1)
(1)
(2)
(1)
(4)
(1)
(2)
(3)
ModelTerminal block marking
VFS2100VFS2200VFS2 00
AA sideA sideA side
COMCOMCOMCOM
B
B sideB side3
4
• Applicable terminal: 1.25-3, 1.25-3S, 1.25Y-3N, 1.25Y-3S
• Plugging COM bridge (part no. AXT625-73: 5 stations) in between each + COM on the block board will make the specifications of all the stations + COM and enables you to understand the wiring process.
• There is no polarity.• Tightening torque for terminal: 0.6 N·m
• Remove junction cover of manifold, exposing terminal block attached to the manifold block. Lead wires from solenoid valve are connected with the terminals on upper side of terminal block. (On the terminal block, lead wire is connected with both A and B sides of solenoid valve in accordance with the corresponding markings A and B on the block.) Connect each lead wire of power side corresponding to respective solenoid valve on the lower terminal block.VFS2000 has the marking + COM on the block board, but – COM specification is also available.
Connection
Marking
ModelTerminal block marking
VFS3100VFS3200VFS3 00
AA sideA sideA side
COMCOMCOMCOM
B
B sideB side3
4
• Applicable terminal:1.25-3.5M, 1.25Y-3L, 1.25-3M
• There is no polarity.• VFS 3000 has the marking + COM on the
block board, but – COM specification is also available.
• Tightening torque for terminal: 0.6 N·m
• Applicable terminal:1.25-3.5M, 1.25Y-3L, 1.25Y-3M
• There is no polarity.• Tightening torque for terminal: 0.6 N·m
ModelTerminal block marking
VFS 100VFS 200VFS4 00VFS5 00
A + A sideA side
A side
A–A sideA side
A side
B +
B side
B side
B–
B side
B side
4545
3434
1226
Series VFSSpecific Product Precautions 4Be sure to read before handling.Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.
P1111-P1228-E.qxd 08.9.2 2:56 PM Page 1226
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Caution
Type 01F D-sub Connector
Series VFS2000/3000/4000/5000 Series VFS2000/3000/4000/5000
Lead Wire Connection Manifold/Plug-in
Type 01C Circular Connector
Note 1) Maximum stations are 8.Note 2) There is no polarity.Note 3) Indication of stations are one station from D side regardless of the
connector mounting side, D or U.
• Wire connection specificationsLead wire for both solenoid A and B sides in manifold are connected to connector terminal as COM specifications.
• Wire connection specificationsLead wire for both solenoid A and B sides in manifold are connected to connector terminal as COM specifications.
Internal Wiring of Manifold
Applicable Plug Assembly (Option)
VVFS2000-30A-1VVFS2000-30A-2
Assembly part no. Cable length1.5 m3 m
VVFS2000-30A-3 5 mVVFS2000-30A-4 ∗ 7 mVVFS2000-30A-5 ∗ 10 mVVFS2000-30A-6 ∗ 15 mVVFS2000-30A-7 ∗ 20 m
Component parts
Plug 206837-1 1 pc. Cable clamp 206138-1 1 pc. Socket 66101-2 24 pcs. Cable VCTF 24 cores x 0.75 mm2
made by Tyco Electronics AMP K.K.
∗ Option
Cable Color List of Each Terminal No.Terminal no. 1
Orange Orange
—
2
Yes Yes Yes Yes Yes Yes
3Black Black
—
4 5
—
6Green Green Red Red Blue Blue Yellow Yellow
7
—
8 9
—
10 11
—
12Lead wire colorDot marking
Terminal no.Lead wire colorDot marking
Cable Color List of Each Terminal No.Terminal no. 1
Black Brown
— —
2
White Black Red Red Red
3Red Orange
— —
4 5
— —
6Yellow Pink Blue Purple Gray White White Yellow Orange
7
—
8 9
Black
10 11 12 13Lead wire color
Note 1) Maximum stations are 8.Note 2) There is no polarity.Note 3) Indication of stations are one station from D side regardless of the
connector mounting side, D or U.
Internal Wiring of Manifold
Applicable Plug Assembly (Option)
AXT100-DS25-015AXT100-DS25-030
Assembly part no. Cable length1.5 m3 m
AXT100-DS25-050 5 mAXT100-DS25-080 8 mAXT100-DS25-100 10 mAXT100-DS25-150 15 mAXT100-DS25-200 30 m
Component parts
AXT100-DS25-300 20 m
Dot marking
Terminal no.Lead wire colorDot marking Black Black BlackWhite White White WhiteRed
Yellow Pink Blue Purple Gray Orange Red Brown Pink
14 15 16 17
—
18 19
— —
20 21 22
Red
Gray Black White
23 24 25
D-sub connector
Standard Wiring with control unit
Multi-connector
Standard Wiring with control unit
Fig. (1) U side
Station
D side
Fig. (2)
Station
Connector terminal Connector terminal Connector terminal Connector terminal
U side
D side
Plug: MIL standard D type connector25 terminals Cable: 25 cores wire x 0.3 mm2
Applicable plug assembly (Option)
(1)(2)
(3)(n)
(1)(2)
(3)(n)
Applicable plug assembly (Option)
Connector terminal no.
1 station
Air release valve1station
2station
Pressure switch
Con
trol u
nit
3 station
4 station
5 station
6 station
7 station
2 station
3 station
4 station
5 station
6 station
7 station
Max.8 stations
Max.8 stations
Connectorterminal no.
1 station
Air release valve1station
2station
Pressure switch
Con
trol u
nit
3 station
4 station
5 station
6 station
7 station
3 station
4 station
5 station
6 station
7 station
Max.8 stations
Max.8 stations
2 station
23
Yes Yes Yes Yes Yes
Brown Brown White White Pink Pink Gray Gray Sky blue Sky blue Light green Light green
13
—
14 15
—
16 17
—
18 19
—
20 21
—
22 24
Yes—
1227
Series VFSSpecific Product Precautions 5Be sure to read before handling.Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.
SJ
SY
SV
SYJ
SZ
VP4
S0700
VQ
VQ4
VQ5
VQC
VQZ
SQ
VFS
VFR
VQ7
1-02-16-VFS1000.qxd 10.1.26 2:02 PM Page 2
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
1228
P1111-P1228-E.qxd 08.9.2 2:56 PM Page 1228
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com