50 years thermal management - seifert systemsseifertsystems.com.au/docs/seifert-products2015.pdf ·...

20
1 9 6 5 - 2 0 1 5 SoliTherm Control Cabinet Air Conditioning 50 Years Thermal Management www.seifertsystems.com

Upload: others

Post on 01-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Products2015.pdf · 50 1965 - 2015 SoliTherm Control Cabinet Air Conditioning 50 Years Thermal Management

501 9 6 5 - 2 0 1 5

Sol iTherm Contro l Cabinet A ir Condit ion ing

50 Years Thermal Management

www.seifertsystems.com

Page 2: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Products2015.pdf · 50 1965 - 2015 SoliTherm Control Cabinet Air Conditioning 50 Years Thermal Management

Page

So l iTherm ComPact 5 - 6

So l iTherm ComPact Recessed 7 - 8

So l iTherm 19” Rack & Top mount 9

So l iTherm S l imL ine 11 - 12

So l iTherm Coo lMatch 13

Pe l t ie r Coo l ing Un i ts 15

So l iTherm Outdoor 17 - 18

More Se i fe r t Produc ts 19

Technical rights reserved

Table of Contents

Page 3: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Products2015.pdf · 50 1965 - 2015 SoliTherm Control Cabinet Air Conditioning 50 Years Thermal Management

Cooling capacity (DIN 3168) Rated voltage Mounting Dimensions Page

Type L35L35 ( H x W x D ) mmKG 4304 320 W • • • • • • 500 x 280 x 200 5

KG 4305 550 W • • • • • • 650 x 315 x 260 5 / 7

KG 4308 750 W • • • • • • 650 x 315 x 260 5 / 7

KG 4309 850 W • • • • • • 650 x 315 x 260 5 / 7

KG 4310 1,000 W • • • • • • 650 x 315 x 260 5 / 7

KG 4315 1,500 W • • • • • • 980 x 395 x 260 6 / 8

KG 4320 2,000 W • • • • • • 980 x 395 x 260 6 / 8

KG 4325 2,500 W • • • • • • 1,230 x 500 x 340 6 / 8

KG 4330 3,000 W • • • • • • 1,230 x 500 x 340 6 / 8

KG 4340 4,000 W • • • • • 1,230 x 500 x 340 6 / 8

KG 4266 320 W • • • • 520 x 270 x 110 11

KG 4267 400 W • • • • 340 x 520 x 110 11

KG 4268 400 W • • • • 520 x 320 x 110 11

KG 4269 500 W • • • • 600 x 320 x 110 11

KG 4270 600 W • • • • • • 810 x 395 x 145 12

KG 4271 820 W • • • • • • 980 x 395 x 145 12

KG 4272 1,100 W • • • • • • 1250 x 395 x 145 12

KG 4274 1,500 W • • • • • • 1550 x 395 x 145 12

KG 2019 520 W • • • 3U x 19” x 564.5 13

KG 2020 520 W • • • 3U x 19” x 19” 13

KG 2025 520 W • • • • 310 x 475 x 98 13

KG 2002 520 W • • • 260 x 203.2 x 220 13

KG 4482 450 W • • • 230 x 430 x 330 9

KG 4555 1,100 W • • • • • 400 x 600 x 400 9

KG 4533 550 W • • 222 x 483 x 549 9

KG 4534 850 W • • 266 x 483 x 549 9

KG 4535 900 W • • • 265 x 444 x 565 9

OC 5705 550 W • • • • • 830 x 315 x 270 17

OC 5708 750 W • • • • • 830 x 315 x 270 17

OC 5709 850 W • • • • • 830 x 315 x 270 17

OC 5710 1,000 W • • • • • 900 x 315 x 270 17

OC 5715 1,500 W • • • • • 1150 x 395 x 270 18

OC 5720 2,000 W • • • • • 1150 x 395 x 270 18

OC 5725 2,500 W • • • • • 1550 x 495 x 355 18

OC 5730 3,000 W • • • • • 1550 x 495 x 355 18

OC 5740 4,000 W • • • • 1550 x 495 x 355 18

Peltier cooling unitsTG 3050 50 W • • • 206 x 154 x 135 15

TG 3102 100 W • • • 304 x 200 x 138 15

TG 3152 150 W • • • 400 x 180 x 171 15

TG 3152 175 W • • • 400 x 180 x 171 15

TG 3200 200 W • • • 400 x 180 x 171 15

TG 3200 250 W • • • 400 x 180 x 171 15

230 V

400 V

24 V

120 V

460 V

48 V

Ext

Int

Rece

ss

TOP

19 “

Page 4: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Products2015.pdf · 50 1965 - 2015 SoliTherm Control Cabinet Air Conditioning 50 Years Thermal Management

SoliTherm ComPact | the economica l a l l - round so lu t ion

Re l i ab i l i t y and use r f r i end l i ness a re t he bes t ways t o desc r i be t he e lec t ron i c con t ro l l e r be ing used i n t he ComPac t a i r cond i t i one rs . The d i sp lay i nd i ca tes t empera tu re and ope ra t i ng s ta tus and can be eas i l y se t and ad jus ted by t he use r v i a a Touch Pad .

A comple te mode l range f rom 320 W up to 4kW wi th s imp le opera t ion were the key ideas dur ing the deve lopment . We have a lso p laced a s t rong emphas is in s tandard iz ing components , vers ions and s izes thus d im in ish ing the need o f la rge spare par t s tocks , complex t ra in ing o r long un i t se lec t ion p rocesses .

Al l ComPact un i ts have a powder coated mi ld s tee l hous ing (RAL 7035) . For appl icat ions were hygiene and corros ion p ro tec t ion a re requ i red , we o f fe r a s ta in less s tee l cover fo r a l l ComPact mode ls . Un i ts w i th a coo l ing capac i ty o f 2 kW and above can be op t iona l l y supp l ied w i th an e lec t r i c condensate evapora to r.

For a un iversa l use o f our ComPact un i ts we o f fe r a lso mode ls fo r recessed mount ing . The ava i lab le recessed depth (A) var ies f rom 30mm to 120mm. The par t numbers XXXXXX81 have a s tandard depth o f 90mm. K ind ly con tac t us fo r o ther mode ls and par t numbers .

Page 5: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Products2015.pdf · 50 1965 - 2015 SoliTherm Control Cabinet Air Conditioning 50 Years Thermal Management

5www.seifertsystems.com

Note: The IP rating on the ambient side can be increased by using filter mats

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Sol iTherm ComPactUL Type12

Part-no. Cooling capacityL35L35 / L35L50 (DIN3168)

Voltage / Frequency Operating temp. range

IP protection to IEC 60 529 Ext/ Int Weight (Kg) QR Code

Dimensions (H x W x D): 500 x 280 x 200 mm

43040001 320 W / 200 W 230 V - 50/60 Hz +20°C - +55°C 24 / 54 18

Dimensions (H x W x D): 500 x 280 x 270 mm

43041001 320 W / 240 W 120 V - 60 Hz +20°C - +55°C 24 / 54 26

KG 430443042001 320 W / 240 W 400/460 V - 50/60 Hz 2~ +20°C - +55°C 24 / 54 26

Dimensions (H x W x D): 650 x 315 x 260 mm

43050001 550 W / 410 W 230 V - 50/60 Hz +20°C - +55°C 24 / 54 27.7

KG 4305

43051001 550 W / 410 W 120 V - 60 Hz +20°C - +55°C 24 / 54 33.7

43052001 550 W / 410 W 400/460 V - 50/60 Hz 2~ +20°C - +55°C 24 / 54 33.7

43080001 750 W / 470 W 230 V - 50/60 Hz +20°C - +55°C 24 / 54 27.7

KG 4308

43081001 750 W / 480 W 120 V - 60 Hz +20°C - +55°C 24 / 54 33.7

43082001 750 W / 480 W 400/460 V - 50/60 Hz 2~ +20°C - +55°C 24 / 54 33.7

43090001 850 W / 610 W 230 V - 50/60 Hz +20°C - +55°C 24 / 54 30

KG 4309

43091001 850 W / 600 W 120 V - 60 Hz +20°C - +55°C 24 / 54 36

43092001 850 W / 600 W 400/460 V - 50/60 Hz 2~ +20°C - +55°C 24 / 54 36

43100001 1 kW / 660 W 230 V - 50/60 Hz +20°C - +55°C 24 / 54 30

KG 4310

43101001 1 kW / 660 W 120 V - 60 Hz +20°C - +55°C 24 / 54 36

43102001 1 kW / 720 W 400/460 V - 50/60 Hz 2~ +20°C - +55°C 24 / 54 36

Page 6: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Products2015.pdf · 50 1965 - 2015 SoliTherm Control Cabinet Air Conditioning 50 Years Thermal Management

6 www.seifertsystems.com

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Note: The IP rating on the ambient side can be increased by using filter mats

Sol iTherm ComPactUL Type12

Part-no. Cooling capacityL35L35 / L35L50 (DIN3168)

Voltage / Frequency Operating temp. range

IP protection to IEC 60 529 Ext/ Int Weight (Kg) QR Code

Dimensions (H x W x D): 980 x 395 x 260 mm

43150001 1.50 kW / 1.22 kW 230 V - 50/60 Hz +20°C - +55°C 24 / 54 39.7

KG 4315

43151001 1.50 kW / 1.22 kW 120 V - 60 Hz +20°C - +55°C 24 / 54 47.7

43152001 1.50 kW / 1.22 kW 400/460 V - 50/60 Hz 2~ +20°C - +55°C 24 / 54 47.7

43200001 2 kW / 1.6 kW 230 V - 50/60 Hz +20°C - +55°C 24 / 54 44.2

KG 4320

43201001 2 kW / 1.6 kW 120 V - 60 Hz +20°C - +55°C 24 / 54 50

43202001 2 kW / 1.63 kW 400/460 V - 50/60 Hz 3~ +20°C - +55°C 24 / 54 44.2

Dimensions (H x W x D): 1,230 x 500 x 340 mm

43250001 2.5 kW / 1.97 kW 230 V - 50/60 Hz +20°C - +55°C 24 / 54 67.5

KG 4325

43251001 2.5 kW / 1.97 kW 120 V - 60 Hz +20°C - +55°C 24 / 54 73

43252001 2.5 kW / 1.97 kW 400/460 V - 50/60 Hz 3~ +20°C - +55°C 24 / 54 73

43300001 3 kW / 2.38 kW 230 V - 50/60 Hz +20°C - +55°C 24 / 54 67.5

KG 4330

43301001 3 kW / 2.42 kW 120 V - 50/60 Hz +20°C - +55°C 24 / 54 75

43302001 3 kW / 2.39 kW 400/460 V - 50/60 Hz 3~ +20°C - +55°C 24 / 54 72.5

43400001 4 kW / 3.18 kW 230 V - 50/60 Hz +20°C - +55°C 24 / 54 69

KG 434043402001 4 kW / 3.17 kW 400/460 V - 50/60 Hz 3~ +20°C - +55°C 24 / 54 72.5

Page 7: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Products2015.pdf · 50 1965 - 2015 SoliTherm Control Cabinet Air Conditioning 50 Years Thermal Management

7www.seifertsystems.com

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Note: The IP rating on the ambient side can be increased by using filter mats

Sol iTherm ComPact recessed

Part-no. Cooling capacityL35L35 / L35L50 (DIN3168)

Voltage / Frequency Operating temp. range

IP protection to IEC 60 529 Ext/ Int Weight (Kg) QR Code

Dimensions (H x W x D): 715 x 372 x 260 mm (incl. 90 mm recess)

43050081 550 W / 410 W 230 V - 50/60 Hz +20°C - +55°C 24 / 54 27.7

KG 4305

43051081 550 W / 410 W 120 V - 60 Hz +20°C - +55°C 24 / 54 33.7

43052081 550 W / 410 W 400/460 V - 50/60 Hz 2~ +20°C - +55°C 24 / 54 33.7

43080081 750 W / 470 W 230 V - 50/60 Hz +20°C - +55°C 24 / 54 27.7

KG 4308

43081081 750 W / 480 W 120 V - 60 Hz +20°C - +55°C 24 / 54 33.7

43082081 750 W / 480 W 400/460 V - 50/60 Hz 2~ +20°C - +55°C 24 / 54 33.7

43090081 850 W / 610 W 230 V - 50/60 Hz +20°C - +55°C 24 / 54 30

KG 4309

43091081 850 W / 600 W 120 V - 60 Hz +20°C - +55°C 24 / 54 36

43092081 850 W / 600 W 400/460 V - 50/60 Hz 2~ +20°C - +55°C 24 / 54 36

43100081 1 kW / 660 W 230 V - 50/60 Hz +20°C - +55°C 24 / 54 30

KG 4310

43101081 1 kW / 660 W 120 V - 60 Hz +20°C - +55°C 24 / 54 36

43102081 1 kW / 720 W 400/460 V - 50/60 Hz 2~ +20°C - +55°C 24 / 54 36

Page 8: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Products2015.pdf · 50 1965 - 2015 SoliTherm Control Cabinet Air Conditioning 50 Years Thermal Management

8 www.seifertsystems.com

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Note: The IP rating on the ambient side can be increased by using filter mats

Sol iTherm ComPact recessed

Part-no. Cooling capacityL35L35 / L35L50 (DIN3168)

Voltage / Frequency Operating temp. range

IP protection to IEC 60 529 Ext/ Int Weight (Kg) QR Code

Dimensions (H x W x D): 1045 x 452 x 270 mm (incl. 90 mm recess)

43150081 1.5 kW / 1.22 kW 230 V - 50/60 Hz +20°C - +55°C 24 / 54 39.7

KG 4315

43151081 1.5 kW / 1.22 kW 120 V - 60 Hz +20°C - +55°C 24 / 54 47.7

43152081 1.5 kW / 1.22 kW 400/460 V - 50/60 Hz 2~ +20°C - +55°C 24 / 54 47.7

43200081 2 kW / 1.6 kW 230 V - 50/60 Hz +20°C - +55°C 24 / 54 44.2

KG 4320

43201081 2 kW / 1.6 kW 120 V - 60 Hz +20°C - +55°C 24 / 54 50

43202081 2 kW / 1.63 kW 400/460 V - 50/60 Hz 3~ +20°C - +55°C 24 / 54 44.2

Dimensions (H x W x D): 1,295 x 557 x 340 mm (incl. 90 mm recess)

43250081 2.5 kW / 1.97 kW 230 V - 50/60 Hz +20°C - +55°C 24 / 54 67.5

KG 4325

43251081 2.5 kW / 1.97 kW 120 V - 60 Hz +20°C - +55°C 24 / 54 73

43252081 2.5 kW / 1.97 kW 400/460 V - 50/60 Hz 3~ +20°C - +55°C 24 / 54 73

43300081 3 kW / 2.38 kW 230 V - 50/60 Hz +20°C - +55°C 24 / 54 67.5

KG 4330

43301081 3 kW / 2.42 kW 120 V - 50/60 Hz +20°C - +55°C 24 / 54 75

43302081 3 kW / 2.39 kW 400/460 V - 50/60 Hz 3~ +20°C - +55°C 24 / 54 72.5

43400081 4 kW / 3.18 kW 230 V - 50/60 Hz +20°C - +55°C 24 / 54 69

KG 434043402081 4 kW / 3.17 kW 400/460 V - 50/60 Hz 3~ +20°C - +55°C 24 / 54 72.5

Page 9: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Products2015.pdf · 50 1965 - 2015 SoliTherm Control Cabinet Air Conditioning 50 Years Thermal Management

9www.seifertsystems.com

Sol iTherm TOP & 19” rack mounted

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

UL Type12

Part-no. Cooling capacityL35L35 / L35L50 (DIN3168)

Voltage / Frequency Operating temp. range

IP protection to IEC 60 529 Ext/ Int Weight (Kg) QR Code

Dimensions (H x W x D): 230 x 430 x 330 mm

44820001 450 W / 280 W 230 V - 50/60 Hz +20°C - +50°C 24 / 54 23

KG 448244821001 450 W / 280 W 120 V - 60 Hz +20°C - +50°C 24 / 54 23

Dimensions (H x W x D): 400 x 600 x 400 mm

45550001 1.1 kW / 700 W 230 V - 50/60 Hz +20°C - +55°C 24 / 54 55

KG 4555

45551001 1.1 kW / 700 W 120 V - 60 Hz +20°C - +55°C 24 / 54 55

45552001 1.1 kW / 700 W 400/460 V - 50/60 Hz 3~ +20°C - +55°C 24 / 54 55

19” Rack mounted

45330001 550 W / 370 W 230 V - 50/60 Hz +20°C - +55°C 24 / 54 28

KG 4533

45340001 850 W / 590 W 230 V - 50/60 Hz +20°C - +55°C 24 / 54 33

KG 4534

4535000 900 W / 700 W 230 V - 50/60 Hz +20°C - +55°C 24 / 44 45

KG 45354535100 900 W / 700 W 120 V - 60 Hz +20°C - +55°C 24 / 44 45

Page 10: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Products2015.pdf · 50 1965 - 2015 SoliTherm Control Cabinet Air Conditioning 50 Years Thermal Management

10 www.seifertsystems.com

SoliTherm SlimLine | f i l te r less techno logy fo r more sa fe ty

Maximum power to s ize rat io – th is character ises the Sl imLine a i r condi t ioners. Compat ib i l i ty wi th market s tandards ensures the customer an easy in tegrat ion wi th h is enc losure or cabinet systems. S l imLine a i r condi t ioners a re des igned to opera te w i th abso lu te ly min imum main tenance. They a re eco- f r iend ly and do no t need d i r t co l lec t ing f i l te r mats .

The op t im ised w ide- r ibbed a lumin ium condenser p rov ides improved coo l ing per fo rmance and ensures re l iab i l i t y in indus t r ia l opera t ions . H igh qua l i t y components fo rm the bas is fo r the smooth runn ing and long work ing l i fe o f the S l imL ine a i r cond i t ioners .

T h e u n i t s c a n b e e x t e r n a l l y o r i n t e r n a l l y m o u n t e d a n d a r e o n l y 11 0 m m d e e p a n d t h e r e f o r e c u r r e n t l y t h e s l i m m e s t a i r c o n d i t i o n e r o n t h e m a r k e t . W i t h r e c e s s e d m o u n t i n g t h e u n i t s w i l l o n l y b e 2 5 m m o u t o f t h e c a b i n e t w a l l . A s o n l y s m a l l a p e r t u r e s n e e d t o b e c u t f o r m o u n t i n g , t h e c a b i n e t d o o r s r e m a i n s t a b l e .

As an op t ion , a l l S l imL ine mode ls can be upgraded w i th a master / s lave func t ion wh ich a l lows to connec t up to 20 un i ts toge ther, a d isp lay, an IP address , the poss ib i l i ty to download operat ional data and a USB connect ion.

By add ing a NEMA COVER KIT made o f V2A (A IS I 304 / 1 .4301) to your ex is t ing o r new S l imL ine coo l ing un i ts , they can be upgraded to pass the s t r i c t NEMA 4x ( IP 56) ra t ing . In th is way, the un i ts a re su i tab le fo r the food indus t ry and ou tdoor app l i ca t ions where requ i rements aga ins t hose water and ingress p ro tec t ion a re necessary. Wi th h igher ambien t tempera tu res , the coo l ing capac i ty can be reduced by approx imate ly 10%.

NEMA 4X part.no.

SlimLine model

Dimension (H x W x D) mm

S/M5930017544 KG 4266 600 x 280 x 220

S/M5930018050 KG 4268 650 x 342 x 220

S/M5930017545 KG 4269 680 x 330 x 220

S/M5930019506 KG 4270 1010 x 420 x 282

S/M5930018030 KG 4271 1101 x 420 x 282

S/M5930019200 KG 4272 1400 x 420 x 282

S/M5930016726 KG 4274 1680 x 420 x 282

Page 11: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Products2015.pdf · 50 1965 - 2015 SoliTherm Control Cabinet Air Conditioning 50 Years Thermal Management

11www.seifertsystems.com

SoliTherm SlimLine

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

UL Type12

Part-no. Cooling capacityL35L35 / L35L50 (DIN3168)

Voltage / Frequency Operating temp. range

IP protection to IEC 60 529 Ext/ Int Weight (Kg) QR Code

Dimensions (H x W x D): 520 x 270 x 110 mm

42660001 320 W / 140 W 230 V - 50/60 Hz +20°C - +50°C 24 / 54 13

KG 426642661001 320 W / 140 W 120 V - 60 Hz +20°C - +50°C 24 / 54 13

Dimensions (H x W x D): 340 x 520 x 110 mm

42670001 400 W / 195 W 230 V - 50/60 Hz +20°C - +50°C 24 / 54 14.8

KG 426742671001 400 W / 195 W 120 V - 60 Hz +20°C - +50°C 24 / 54 14.8

Dimensions (H x W x D): 520 x 320 x 110 mm

42680001 400 W / 155 W 230 V - 50/60 Hz +20°C - +50°C 24 / 54 14.8

KG 426842681001 400 W / 155 W 120 V - 60 Hz +20°C - +50°C 24 / 54 14.8

Dimensions (H x W x D): 600 x 320 x 110 mm

42690001 500 W / 160 W 230 V - 50/60 Hz +20°C - +50°C 24 / 54 15.8

KG 426942691001 500 W / 160 W 120 V - 60 Hz +20°C - +50°C 24 / 54 15.8

Page 12: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Products2015.pdf · 50 1965 - 2015 SoliTherm Control Cabinet Air Conditioning 50 Years Thermal Management

12 www.seifertsystems.com

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

SoliTherm SlimLine

UL Type12

Part-no. Cooling capacityL35L35 / L35L50 (DIN3168)

Voltage / Frequency Operating temp. range

IP protection to IEC 60 529 Ext/ Int Weight (Kg) QR Code

Dimensions (H x W x D): 810 x 395 x 145 mm

42700001 600 W / 300 W 230 V - 50/60 Hz +20°C - +50°C 24 / 54 30

KG 4270

42701001 600 W / 300 W 120 V - 60 Hz +20°C - +50°C 24 / 54 30

42702001 600 W / 300 W 400/460 V - 50/60 Hz 2~ +20°C - +50°C 24 / 54 33

Dimensions (H x W x D): 980 x 395 x 145 mm

42710001 820 W / 480 W 230 V - 50/60 Hz +20°C - +55°C 24 / 54 33

KG 4271

42711001 820 W / 480 W 120 V - 60 Hz +20°C - +55°C 24 / 54 34

42712001 820 W / 480 W 380/415 V - 50 Hz 3~400/460 V - 60 Hz 3~ +20°C - +55°C 24 / 54 38

Dimensions (H x W x D): 1250 x 395 x 145 mm

42720001 1.1 kW / 710 W 230 V - 50/60 Hz +20°C - +55°C 24 / 54 44

KG 4272

42721001 1.1 kW / 710 W 120 V - 60 Hz +20°C - +55°C 24 / 54 44

42722001 1.1 kW / 710 W 380/415 V - 50 Hz 3~400/460 V - 60 Hz 3~ +20°C - +55°C 24 / 54 45

Dimensions (H x W x D): 1550 x 395 x 145 mm

42740001 1.5 k / 1.2 kW 230 V - 50/60 Hz +20°C - +55°C 24 / 54 50

KG 4274

42741001 1.5 k / 1.2 kW 120 V - 60 Hz +20°C - +55°C 24 / 54 50

42742001 1.5 k / 1.2 kW 380/415 V - 50 Hz 3~400/460 V - 60 Hz 3~ +20°C - +55°C 24 / 54 55

Page 13: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Products2015.pdf · 50 1965 - 2015 SoliTherm Control Cabinet Air Conditioning 50 Years Thermal Management

13www.seifertsystems.com

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

SoliTherm CoolMatch | Var iab le coo l ing capac i ty fo r your cab ine t

The u l t r a - compac t and l i gh twe igh t a i r cond i t i one rs a re spec ia l l y des igned fo r sma l l enc losu res w i t h l im i t ed moun t i ng a reas . They can be moun ted ex te rna l l y, r ecessed o r moun ted i n to a 19 ” rack w i t h on l y 3U un i t he igh t . The compac t compresso r w i t h i t s va r i ab le speed , can be se t t o p rov ide on l y t he coo l i ng power wh i ch i s ac tua l l y needed . The cons tan t ad jus tmen t resu l t s i n a ve ry un i f o rm tempera tu re l eve l w i t h i n t he cab ine t and the re fo re s t resses t he e lec t r i ca l componen ts and the coo l i ng s i gn i f i can t l y l ess . Th i s resu l t s i n h i ghe r sa fe t y and l onge r l i f e cyc le . I n add i t i on , t he condensa t i on i ns ide t he cab ine t i s m in im ized . The Coo lMa tch Se r i es se t s new pe r fo rmance - to -s i ze s tanda rds wh i ch makes i t pa r t i cu la r l y su i t ab le f o r app l i ca t i ons such as ba t t e r y coo l i ng . I n case o f emergency t he DC ope ra t i on a l l ows the un i t t o be ba t t e r y ope ra ted . A l l t h i s comes w i t h s i gn i f i can t ene rgy sav ings !

Part-no. Cooling capacityL35L35 / L35L50 (DIN3168)

Voltage / Frequency Operating temp. range

IP protection to IEC 60 529 Ext/ Int Weight (Kg) QR Code

19” Rack mounted

20190240 520 W / 380 W 24 V DC +10°C - +55°C 22 / 54 9

KG 201920190480 520 W / 380 W 48 V DC +10°C - +55°C 22 / 54 9

19” Rack mounted

20200240 520 W / 380 W 24 V DC +10°C - +55°C 22 / 54 8.6

KG 202020200480 520 W / 380 W 48 V DC +10°C - +55°C 22 / 54 8.6

Dimensions (H x W x D): 310 x 475 x 98 mm

20250240 520 W / 380 W 24 V DC +10°C - +55°C 22 / 54 7.9

KG 202520250480 520 W / 380 W 48 V DC +10°C - +55°C 22 / 54 7.9

Dimensions (H x W x D): 260 x 203.2 x 220 mm

20020240 520 W / 380 W 24 V DC +10°C - +55°C 22 / 54 7.2

KG 200220020480 520 W / 380 W 48 V DC +10°C - +55°C 22 / 54 6.8

Page 14: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Products2015.pdf · 50 1965 - 2015 SoliTherm Control Cabinet Air Conditioning 50 Years Thermal Management

14

SoliTherm Peltier | the u l t ra -compact coo l ing un i ts

The innova t ive Pe l t ie r thermoe lec t r i c techno logy p rov ides an e f fec t i ve coo l ing so lu t ion v i r tua l l y ma in tenance f ree . The So l iTherm Pe l t ie r a i r cond i t ioners incorpora te the techno logy w i th in a s leek and modern des ign rang ing f rom 50W to 250W.

Thermoelect r ic e lements create a temperature d i f ference between the in ternal and ambient heat s inks, making in te rna l a i r coo le r wh i le d iss ipa t ing the heat ou t to the ex te rna l env i ronment . Fans help the transfer of convective hea t f rom the heat s inks , wh ich a re op t im ised fo r max imum f low.

These a i r cond i t ioners come in powder -coa ted sheet s tee l o r s ta in less s tee l hous ings accord ing to cus tomer ’s requ i rements . They can be mounted in any pos i t ion because these un i ts don ’ t have a compressor. P lease no te tha t the in tegra ted condensat ion management may vary depend ing on the mount ing s i tua t ion .

So l iTherm Pe l t ie r coo l ing un i ts a re res is tan t to ex t reme ambien t cond i t ions and can opera te e f fec t i ve ly even in env i ronments wh ich a re dus ty and o i l y and where tempera tu res may vary f rom -20°C to 65°C. They comply w i th European s tandards IEC/TC 62610-1 and IEC/TC 62610-3 , and can be used bo th fo r indoor and ou tdoor app l i ca t ions .

Cont ro l le rs and thermosta ts fo r Pe l t ie r un i ts a re ava i lab le on reques t

Page 15: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Products2015.pdf · 50 1965 - 2015 SoliTherm Control Cabinet Air Conditioning 50 Years Thermal Management

15www.seifertsystems.com

SoliTherm Peltier

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

UL Type12

Part-no. Cooling capacityL35L35 Voltage / Frequency Operating

temp. rangeIngress IP protection Weight (Kg) QR Code

Dimensions (H x W x D): 206 x 154 x 135 mm

3050303 50 W 24 V DC -20°C - +65°C IP 66 3.3

Dimensions (H x W x D): 302 x 158 x 137 mm

3050305 50 W 24 V DC -20°C - +65°C IP 66 3.9TG 3050

Dimensions (H x W x D): 304 x 200 x 138 mm

3102303 100 W 24 V DC -20°C - +65°C IP 66 5.9

Dimensions (H x W x D): 306 x 302 x 140 mm

3102305 100 W 24 V DC -20°C - +65°C IP 66 7.4TG 3102

Dimensions (H x W x D): 400 x 180 x 171 mm

3152303 150 W 24 V DC -20°C - +65°C IP 66 9

TG 31523152308 175 W 48 V DC -20°C - +65°C IP 66 9

3200303 200 W 24 V DC -20°C - +65°C IP 66 9

TG 32003200308 250 W 48 V DC -20°C - +65°C IP 66 9

Dimensions (H x W x D): 500 x 188 x 174 mm

3152305 150 W 24 V DC -20°C - +65°C IP 66 12.7

TG 31523152310 175 W 48 V DC -20°C - +65°C IP 66 12.7

3200305 200 W 24 V DC -20°C - +65°C IP 66 12.7

TG 32003200310 250 W 48 V DC -20°C - +65°C IP 66 12.7

Page 16: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Products2015.pdf · 50 1965 - 2015 SoliTherm Control Cabinet Air Conditioning 50 Years Thermal Management

16 www.seifertsystems.com

SoliTherm Outdoor | the economica l ou tdoor so lu t ion

Outdoor cond i t ions can be harsh on con t ro l cab ine ts , there fo re our un i ts a re thorough ly des igned to p ro tec t your cab ine ts aga ins t any ingress o f fo re ign so l id and / o r l i qu id mater ia l tha t cou ld po ten t ia l l y damage the sens i t i ve e lec t ron ic components .The h igh f in separa t ion nanocoated condenser requ i res a lmost no ma in tenance and serv ice . Our wa l l mounted coo l ing un i ts opera te be tween -20°C and 55°C. An op t iona l hea te r k i t i s ava i lab le to hea t the in te rna l cab ine t tempera tu re when necessary.

A l l So l iTherm Outdoor coo l ing un i ts a re equ ipped w i th our new e lec t ron ic con t ro l le r, wh ich cons tan t l y mon i to rs the p re -se t cab ine t tempera tu re . Depend ing on the tempera tu re and the power loss ins ide the cab ine t , the coo l ing o r hea t ing c i rcu i ts w i l l be sw i tched on and o f f accord ing ly. Energy sav ing and ex tended component l i fe a re the pos i t i ve e f fec ts . The So l iTherm Outdoor range o f fe rs coo l ing capac i t ies f rom 550 W up to 4 kW and has as a s tandard IP 56 ra t ing towards the cab ine t (NEMA 12, 3 , 3R, 4 , 4X) .

Fu l l s ta in less s tee l vers ions even meet the NEMA 4X requ i rements . A l l un i ts come w i th a cover in mi ld s tee l , powder coa ted (RAL 7035) . Opt iona l s ta in less s tee l covers a re ava i lab le fo r improved cor ros ion p ro tec t ion .

Page 17: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Products2015.pdf · 50 1965 - 2015 SoliTherm Control Cabinet Air Conditioning 50 Years Thermal Management

17www.seifertsystems.com

Part-no. Cooling capacityL35L35 / L35L50 (DIN3168)

Voltage / Frequency Operating temp. range

IP protection to IEC 60 529 Ext/ Int Weight (Kg) QR Code

Dimensions (H x W x D): 830 x 315 x 270 mm

570500001 550 W / 410 W 230 V - 50/60 Hz -20°C - +55°C IP 56 30

OC 5705

570510001 550 W / 410 W 120 V - 60 Hz -20°C - +55°C IP 56 35

570520001 550 W / 410 W 400/460 V - 50/60 Hz 2~ -20°C - +55°C IP 56 35

570800001 750 W / 470 W 230 V - 50/60 Hz -20°C - +55°C IP 56 30

OC 5708

570810001 750 W / 480 W 120 V - 60 Hz -20°C - +55°C IP 56 35

570820001 750 W / 480 W 400/460 V - 50/60 Hz 2~ -20°C - +55°C IP 56 35

570900001 850 W / 610 W 230 V - 50/60 Hz -20°C - +55°C IP 56 32

OC 5709

570910001 850 W / 600 W 120 V - 60 Hz -20°C - +55°C IP 56 37

570920001 850 W / 600 W 400/460 V - 50/60 Hz 2~ -20°C - +55°C IP 56 37

Dimensions (H x W x D): 900 x 315 x 270 mm

571000001 1 kW / 660 W 230 V - 50/60 Hz -20°C - +55°C IP 56 38

OC 5710

571010001 1 kW / 660 W 120 V - 60 Hz -20°C - +55°C IP 56 45

571020001 1 kW / 720 W 400/460 V - 50/60 Hz 2~ -20°C - +55°C IP 56 45

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

UL Type 12, 3, 3R, 4, 4X

SoliTherm Outdoor

Page 18: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Products2015.pdf · 50 1965 - 2015 SoliTherm Control Cabinet Air Conditioning 50 Years Thermal Management

18 www.seifertsystems.com

SoliTherm Outdoor

Part-no. Cooling capacityL35L35 / L35L50 (DIN3168)

Voltage / Frequency Operating temp. range

IP protection to IEC 60 529 Ext/ Int Weight (Kg) QR Code

Dimensions (H x W x D): 1150 x 395 x 270 mm

571500001 1.5 kW / 1.22 kW 230 V - 50/60 Hz -20°C - +55°C IP 56 48

OC 5715

571510001 1.5 kW / 1.22 kW 120 V - 60 Hz -20°C - +55°C IP 56 55

571520001 1.5 kW / 1.22 kW 400/460 V - 50/60 Hz 2~ -20°C - +55°C IP 56 55

572000001 2 kW / 1.6 kW 230 V - 50/60 Hz -20°C - +55°C IP 56 49

OC 5720

572010001 2 kW / 1.6 kW 120 V - 60 Hz -20°C - +55°C IP 56 53

572020001 2 kW / 1.63 kW 400/460 V - 50/60 Hz 3~ -20°C - +55°C IP 56 50

Dimensions (H x W x D): 1550 x 495 x 355 mm

572500001 2.5 kW / 1.97 kW 230 V - 50/60 Hz -20°C - +55°C IP 56 68

OC 5725

572510001 2.5 kW / 2 kW 120 V - 60 Hz -20°C - +55°C IP 56 75

572520001 2.5 kW / 2 kW 400/460 V - 50/60 Hz 3~ -20°C - +55°C IP 56 75

573000001 3 kW / 2.4 kW 230 V - 50/60 Hz -20°C - +55°C IP 56 70

OC 5730

573010001 3 kW / 2.4 kW 120 V - 60 Hz -20°C - +55°C IP 56 78

573020001 3 kW / 2.4 kW 400/460 V - 50/60 Hz 3~ -20°C - +55°C IP 56 75

574000001 4 kW / 3.3 kW 230 V - 50/60 Hz -20°C - +55°C IP 56 72

OC 5740574020001 4 kW / 3.3 kW 400/460 V - 50/60 Hz 3~ -20°C - +55°C IP 56 72

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

Click herefor full

technicalspecifications

UL Type12, 3, 3R, 4, 4X

Page 19: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Products2015.pdf · 50 1965 - 2015 SoliTherm Control Cabinet Air Conditioning 50 Years Thermal Management

19www.seifertsystems.com

Sei fe r t | Thermal Management So lu t ions

Cont ro l cab ine t hea te rs

Cab ine t hea te rs a re an impor tan t segment o f the Se i fe r t cab ine t accessor ies p rogram and fo rm par t o f our therma l management so lu t ions . Tempera tu re d i f fe rences in cab ine ts , mos t ly in ou tdoor app l i ca t ions , o f ten resu l t in humid i ty and condensat ion wh ich may cause func t ion fa i lu res and cor ros ion . The use o f the appropr ia te hea t ing un i t fo r your cab ine t w i l l e l im ina te these p rob lems. Fan heaters d is t r ibu te the in te rna l warm a i r equa l l y th roughout the con t ro l cab ine t .

A i r / Water Heat Exchangers

Our compact a i r / wa te r hea t exchangers can be used i f a co ld water supp ly i s ava i lab le . Se i fe r t hea t exchangers a re ava i lab le as 19” p lug- in mode ls w i th min ima l dep th , as in te rna l , and as top and s ide mount ing vers ions . These indus t ry p roven heat exchangers d iss ipa te f rom 700W up to 5 .5 kW (L35W10) . W i t h o u r m o d u l a r s y s t e m s e t u p w e c a n e v e n r e a c h p e r f o r m a n c e s o f u p t o 4 0 k W.

A i r / A i r Heat Exchangers

Our counter f low and c ross f low heat exchangers a re des igned bo th fo r ou tdoor and indoor app l i ca t ions . The Se i fe r t h igh-end vacuum braz ing techno logy i s bes t - in -c lass therma l d i s s i p a t i o n and the most compact foo tp r in t in the indus t ry. They comply w i th the NEMA and IP requ i rements . Our customers can a lso opt for u l t imate corros ion protect ion and chromated a lumin ium sur faces.

F i l te r fans

Fi l te r fans a re used i f the des i red cab ine t tempera tu re can be cons tan t l y above the ambien t a i r tempera tu re . In combina t ion w i th thermosta ts f rom Se i fe r t you can save on energy s ince the fan i s on ly on when ac tua l l y needed, on mater ia l because o f less consumpt ion o f f i l te r mats and on t ime s ince less c lean ing i s requ i red . A l l th is w i l l ensure a longer l i fe t ime o f the f i l te r fans and w i l l enhance your p rocess re l iab i l i t y and sa fe ty. A l l our f i l te r fans a re a lso ava i lab le in EMC and NEMA 3R vers ions .

Cont ro l cab ine t accessor ies

In add i t ion to our innova t ive range o f a i r cond i t ioners , Se i fe r t has deve loped a comple te l ine o f accessor ies to meet the d i f fe ren t requ i rements o f our cus tomers . We o f fe r a w ide range o f in te l l i gen t con t ro l le rs , thermosta ts and hygros ta ts , door sw i tches and l igh t ing . Our new s t r ipL i te LED l igh t f i x tu re i s the economica l and space sav ing so lu t ion fo r cab ine t and enc losure l igh t ing . The s ta te o f the a r t LED techno logy ensures a long and ma in tenance f ree l i fe cyc le . In tegra ted on /o f f sw i tches , mot ion sensors and da isy cha in adapters to connec t up to 8 l igh ts a l low var ious poss ib i l i t i es o f ins ta l la t ions d i rec t ing the l igh t to where i t i s ac tua l l y needed.

Page 20: 50 Years Thermal Management - Seifert Systemsseifertsystems.com.au/docs/Seifert-Products2015.pdf · 50 1965 - 2015 SoliTherm Control Cabinet Air Conditioning 50 Years Thermal Management

Seifert Systems GmbH Seifert Systems Ltd. Seifert Systems AG Seifert Systems Inc. Seifert Systems Pty Ltd.

Haßlinghauser Str. 156 HF 09/10 Hal Far Industrial Estate Wilerstraße 16 75 Circuit Drive 105 Lewis Road58285 Gevelsberg Birzebbuga, BBG 3000 CH- 4563 Gerlafingen North Kingstown Wantirna South RI 02852 3152 VictoriaGermany Malta Switzerland USA Australia Tel. +49 (0) 2332 55124-0 Tel. +356 2220 7000 Tel. +41 (0) 32 675 35 51 Tel. +1 401-294-6960 Tel. +61 (3) 98 01 19 06Fax +49 (0) 2332 5512429 Fax +356 2165 2009 Fax +41 (0) 32 675 44 76 Fax +1 401-294-6963 Fax +61 (3) 98 87 08 45

www.seifertsystems.com

www.facebook.com/sei fer t .mtmsystems

© 0

3/2