50hz light commercial · 2019. 3. 18. · 2009 2011 the chigo air-cooled (heat pump) chiller is...

20
50Hz Light Commercial Note:All the data in this book maybe changed without notice for further improvement on quality and performance. Air Conditioner 2013

Upload: others

Post on 23-May-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 50Hz Light Commercial · 2019. 3. 18. · 2009 2011 The Chigo Air-cooled (Heat Pump) Chiller is included in the 2009 Energy-saving Product Catalog of National Commerce Domain The

50Hz Light Commercial

Note:All the data in this book maybe changed without notice for further improvement on quality and performance.

Air Conditioner 2013

Page 2: 50Hz Light Commercial · 2019. 3. 18. · 2009 2011 The Chigo Air-cooled (Heat Pump) Chiller is included in the 2009 Energy-saving Product Catalog of National Commerce Domain The

more than 150 countries and regions all over the world, and set agencies at 31 provinces in China. It has many senior engineers to provide professional design and appropriate service for customers.

CompanyIntroduction

GUANGDONG CHIGO AIR CONDITIONING CO., LTD.(Listing members of the Group, Stock Code: 449.HK)established in 1994 and located in a famous Chinese industrial city Foshan. We are a big modern enterprise and mainly engage in designing, R&D, manufacturing AC as well as distributing AC domestically and internationally.

As a leading enterprise in Chinese AC industry, CHIGO’s designed annual output is 10 million sets, which includes complete series of AC products. We are one of the biggest AC enterprises which have the most complete refrigeration industrial chain. All-in-one production strategy can meet with the diversity of global market demand and render CHIGO to keep fast development speed over many years.

Till today, CHIGO air conditioners won varies strict certification in all important market, including the ISO9001 Quality System Authentication, the ISO14000 Environmental Management System Authentication, China Inspection-free Product Certificate, China Energy-saving Product Certificate, China Compulsory Certificate (CCC), UL certificate of the USA, CE certificate of EU, GS certificate of German, SAA safety certificate of Australia, etc. We also won the award of “Global Green Environment-Protection Energy-Saving Air-conditioning” from United Nations.

The Synopsis of Chigo Central Air-conditioning

Chigo Central Air-conditioning established in 2002, which belongs to GUANGDONG CHIGO AIR CONDITIONING CO.,LTD, a professional Central AC equipment manufacturing and supplying enterprises, with a net of R&D, production,manufac- turing, sales, design, installation and service.

To “Be Professional Central Air-conditioning Supplier”, Chigo Central Air-conditioning dedicate to research,design,manuf- acture and sale Central Air-conditioning. During 8 years developing, it has formed an annual production capacity of 600,000 sets, and become the most complete refrigeration industrial chain in China. All-in-one Production strategy can meet the various market demand and enable CHIGO to be the biggest scale, the width product line, the most complete product series central air-conditioning enterprise in China.Chigo Central Air-conditioning marketing net have covered

Chigo Group

Main performance

2002The Chigo Air-conditioning commence into Commercial Air-conditioning domain

2006The Chigo Central Air-conditioning obtains “The Guangdong Famous Brand Goods”

2009 2011The Chigo Air-cooled (Heat Pump) Chiller is included in the 2009 Energy-saving Product Catalog of National Commerce Domain

The Chigo Central Air-conditioning obtains the title “The Chinese Designers Most Trust Ten Nationality Brand of HVAC in 2009”

The Chigo industrial air-conditioner obtains “the Guangdong Province Famous Brand Goods”

The Postdoctoral Programme & The Best Growth Air Conditioner Supply & The AAA Grade for the Credit Risk Management.

2004The Chigo Central Air-conditioning had been established

2008The Chigo Central Air-conditioning own the honor of “Top Ten National Brands”

2010The Chigo (including Central Air-conditioning) own the honor “the Best Energy-saving prize of Government Procurement Air-conditioning Project in 2009”The Top Ten Brand Enterprises of Low-carbon & Energy-saving Air-conditioning in the Eleventh Five-Year Plan

Page 3: 50Hz Light Commercial · 2019. 3. 18. · 2009 2011 The Chigo Air-cooled (Heat Pump) Chiller is included in the 2009 Energy-saving Product Catalog of National Commerce Domain The

Contents................................................................01

How to Read the models.........................................02

Directory

Light Commercial Universal Outdoor Unit...............03

Light Commercial Universal Indoor Unit.................06

4-way Cassette (Compact) Unit .............................06

4-way Cassette Unit...............................................09

Floor & Ceiling Unit.................................................13

Low ESP Ducted Unit.............................................16

Medium ESP Ducted Unit......................................18

High ESP Ducted Type Unit..................................21

Floor-standing Outdoor Unit...................................23

Floor-standing Indoor Unit......................................25

96K&110K Btu/h High ESP Ducted Outdoor Unit......27

96K&110K Btu/h High ESP Ducted Indoor Unit........29

DC Inverter Multi Split Unit.......................................31

Controller................................................................34

The Testing Center is a comprehensive, multi-functional labortory, mainly used to engage residential and commercial air-conditioner's performance, safety, reliability and authent-ication testing. It takes 6000 square meters, 50 million RMB permanent assets.

It has 9 Air-enthalpy Labs, 3 Condition operating labs, 1 Noise Testing Lab, 2 Long-term Operating Labs, Security Structure Analysis Lab, Air Volume Lab; and labs in planning, EMC, Wet State, Thermal Equilibrium, Capacity Testing and so on.

Profile of Testing Center

Chinese Energy Efficiency Label Management Center's Verification.

15 Engineers, all had got professional training before commencement.

World-class Professional HR.

Long-term Cooperation with

Professional Certification Test

Organization.

Denmark B&K 3560 Acousitics

and Vibration Noise Test

Analysis System.

Page 4: 50Hz Light Commercial · 2019. 3. 18. · 2009 2011 The Chigo Air-cooled (Heat Pump) Chiller is included in the 2009 Energy-saving Product Catalog of National Commerce Domain The

R1

Contents

C:Chigo HVAC

Match Code-- : unitary series; 2: Multi 1 drives2; 3: Multi 1 drives 3;

Product seriesOU: Universal type. OT: Top-discharge; OW: Non-universal typ

Power Code-- : 220-240V/1Ph/50Hz; S: 380V/3Ph/50HZ.

Function code C: Cooling only; H: heat pump

Capacity,unit: kBtu/h

C:Chigo HVAC

Product seriesCA: 4-way cassette; CB: Compact 4-way Cassette; TA: Low ESP Duct; TB: Mid ESP Duct; TH: High ESP Duct; UA: Floor & Ceiling; SG: Multi Wall type; SC: Multi 4-way Cassette; ST:Multi Duct.

Working Condition -- : T1 condition; T:T3 condition.

Working Condition -- : T1 condition; T:T3 condition.

C CA 24 VT E C

Function codeC: Cooling only; H: Heat pump.

E: Electrical auxiliary heater.

Capacity,unit: kBtu/h

V: DC Inv. -- : Fixed speed.

-- : Match universal outdoor unit; i: match individual outdoor unit

Bi

Design No B: second design

Refrigerant -- : R22; R1:R410A

R1V

V: DC Inv. -- : Fixed speed.

B

Design No B: second design

Refrigerant -- : R22; R1:R410A

VC 3 24OU C S

50Hz Light Commercial Air Conditioner 50Hz Light Commercial Air Conditioner

21

7,000

Multi Split

Capacity(Btu/h) 9,000 12,000 14,000 18,000 21,000 27,000Wall-mountedPanel code:84#

Wall-mounted Panel code:87#

Wall-mounted Panel code:107#

Wall-mounted Panel code:103#

Outdoor Unit (1 drives 2)

Outdoor Unit (1 drives 3)

Light Commercial

Capacity(Btu/h) 12,000 18,000 24,000 36,000 48,000 60,000 70,000 96,000

Compact 4-wayCassette Unit

Low ESP Ducted Unit

High ESP DuctedUnit

Floor-ceiling Unit

96K&110K Btu/h High ESP Ducted Unit

Floor-ceiling Unit

4-way Cassette Unit

Medium ESP Ducted Unit

Outdoor Unit

(R22 Only)

Page 5: 50Hz Light Commercial · 2019. 3. 18. · 2009 2011 The Chigo Air-cooled (Heat Pump) Chiller is included in the 2009 Energy-saving Product Catalog of National Commerce Domain The

Outdoor unit

Power supply

Capacity

Physical data

Piping data

Cooling

Capacity

Heating

Compressor

V/Hz/Ph

Btu/hKWWA

Btu/hKWWA

WAA

m3/hdB(A)mmmmkgg

MPa

mmmm

180005.3

19008.64

198005.8

16907.68

250011.36

40RotaryHitachi2800

53866×535×304920×585×335

49/51R410A/1200

4.2

2010

InputRated current

Capacity

InputRated current

TypeBrand

Max. input consumption Max. current Starting current

Outdoor air flow Outdoor noise level Dimension(WxHxD) Packing dimension(WxHxD) Net/Gross weight Refrigerant type/quantity Design pressure

Liquid side/Gas side Max. pipe length Max. high drop

COU-18HR1

220~240/1/50

240007.1

240010.9126400

7.821009.55

270012.27

49RotaryHitachi3800

65930×700×370990×770×410

58/61R410A/1800

4.2

2010

COU-24HR1

220~240/1/50

3600010.5371016.863960011.5331015.05

480021.82112

ScrollSanyo6000

651070×995×4001145×1120×475

92/100R410A/2100

4.2

2010

COU-36HR1

220~240/1/50

3600010.538006.79

3960011.536006.44

49008.7648

ScrollSanyo6000

651070×995×4001145×1120×475

92/100R410A/2100

4.2

2010

COU-36HSR1

380~415/3/50

4800014

50008.94

5280015.451009.12

600010.73

66ScrollSanyo6100

60911×1335×400964×1445×475

96/107R410A/3600

4.2

2010

COU-48HSR1

380~415/3/50

6000016

570010.196600016.6580010.37

660011.870

ScrollSanyo6100

60911×1335×400964×1445×475

96/107R410A/4000

4.2

2010

COU-60HSR1

380~415/3/50

12k/18k Btu/h 24k Btu/h

48k Btu/h

36k Btu/h

48k/60k Btu/h

Light Commercial Universal Outdoor Unit R410A Heating Pump

R410A Cooling Only

50Hz Light Commercial Air Conditioner 50Hz Light Commercial Air Conditioner

43

2

Features:

Famous scroll compressor with quick reactivity, stronger power and operation stable. Anti-attenuation design and better low-temperature heating performance.

Brand-new outdoor unit design, multi-direction piping connection meet different requirement, convenient installation.

1

Environment friend refrigerant R410A.

Front Right

Rear

3

270°

Outdoor unit

Power supply

Capacity

Physical data

Piping data

Cooling

Compressor

V/Hz/Ph

Btu/hKWWA

WAA

m3/hdB(A)mmmmkgg

MPa

mmmm

180005.3

19008.64

250011.36

40RotaryHitachi2800

53866×535×304920×585×335

48/50R410A/1200

4.2

2010

Capacity

InputRated current

TypeBrand

Max. input consumption Max. current Starting current

Outdoor air flow Outdoor noise level Dimension(WxHxD) Packing dimension(WxHxD) Net/Gross weight Refrigerant type/quantity Design pressure

COU-18CR1

220~240/1/50

240007.1

240010.91

270012.27

49RotaryHitachi3800

65930×700×370990×770×410

57/60R410A/1800

4.2

2010

COU-24CR1

220~240/1/50

3600010.5371016.86

480021.82112

ScrollSanyo6000

651070×995×4001145×1120×475

91/99R410A/2100

4.2

2010

COU-36CR1

220~240/1/50

3600010.538006.79

49008.7648

ScrollSanyo6000

651070×995×4001145×1120×475

91/99R410A/2100

4.2

2010

COU-36CSR1

380~415/3/50

4800014

50008.94

600010.73

66ScrollSanyo6100

60911×1335×400964×1445×475

95/106R410A/3600

4.2

2010

COU-48CSR1

380~415/3/50

6000016

570010.19

660011.870

ScrollSanyo6100

60911×1335×400964×1445×475

95/106R410A/4000

4.2

2010

COU-60CSR1

380~415/3/50

Liquid side/Gas side Max. pipe length Max. high drop

R410A

R410A

Page 6: 50Hz Light Commercial · 2019. 3. 18. · 2009 2011 The Chigo Air-cooled (Heat Pump) Chiller is included in the 2009 Energy-saving Product Catalog of National Commerce Domain The

50Hz Light Commercial Air Conditioner 50Hz Light Commercial Air Conditioner

6

Outdoor unit

Power supply

Capacity

Physical data

Piping data

Cooling

Capacity

Capacity

Heating

Compressor

V/Hz/Ph

Btu/hKWWA

Btu/hKWWA

WAA

m3/hdB(A)mmmmkgg

MPa

mmmm

90002.69904.5

100002.99204.1

11505.916

RotaryMitsubishi

200050

735×505×286825×550×320

30/28800

2.7/0.7

6.35/ 9.52158

Rated current

InputRated current

TypeBrand

Max. input consumption Max. current Starting current

Outdoor air flow Outdoor noise level Dimension(WxHxD) Packing dimension(WxHxD) Net/Gross weight Refrigerant type/quantity Design pressure

COU-9H

220~240/1/50

120003.5

13206.1

130003.8

12205.6

16208.327

RotaryMitsubishi

200050

880×540×305920×585×335

35/331000

2.7/0.7

6.35/ 12.7158

COU-12H

220~240/1/50

180005.3

17808.1

200005.8

16307.5

230011.638

RotaryMitsubishi

280053

880×540×305920×585×335

49/511520

2.7/0.7

6.35/ 12.7158

COU-18H

220~240/1/50

240007.1

233010.9

260007.8

214010.2

326014.864.7

RotaryGmcc3800

55925×700×366990×770×410

55/601900

2.7/0.7

9.52/ 15.882010

COU-24H

220~240/1/50

3600010.5398018.2

4000011.5375017.2

537024.6112

ScrollSanyo560060

1050×995×4001145×1120×475

92/1002500 2.7/0.7

9.52/ 19.052010

COU-36H

220~240/1/50

3600010.538006.8

4000011.536806.6

51309.248

ScrollSanyo5600

601050×995×4001145×1120×475

92/1002500 2.7/0.7

9.52/ 19.052010

COU-36HS

380~415/3/50

4800014

52309.5

5200015.451309.3

732013.255

ScrollSanyo560060

1050×995×4001145×1120×475

98/1063000

2.7/0.7

2010

COU-48HS-A

380~415/3/50

4800014

52309.5

5200015.451309.3

732013.255

ScrollSanyo610060

911×1330×400964×1445×402

96/1073500

2.7/0.7

2010

COU-48HS

380~415/3/50

6000016

570010

6000016.6580010.2

760013.573

ScrollSanyo610060

911×1330×400964×1445×402

99/1104000

2.7/0.7

2010

COU-60HS

380~415/3/50

R22 Heating Pump

R22 Cooling Pump

Liquid side/Gas side Max. pipe length Max. high drop

4-way Cassette (Compact) Unit

Three-dimensional centrifugal fan design.4

diffuser

three-dimensionalspiral fan blade

12k/18k Btu/h

Features:

2

Ultra-thin body design, the min. height is only 275mm, save installation space.

5

4-way air flow, cold air can reach each corner of the room, providing a stable and comfortable environment.

1 Compact design,Panel dimension,650*650mm.

3 3 fan speed, meet for different requirement.

275mm

Input

R22 Cooling Only

Outdoor unit

Power supply

Capacity

Physical data

Piping data

Cooling

Compressor

V/Hz/Ph

Btu/hKWWA

WAA

m3/hdB(A)mmmmkgg

MPa

mmmm

90002.69904.5

11505.916

RotaryMitsubishi

200050

735×505×286825×550×320

28/26590

2.7/0.7

6.35/ 9.52158

Capacity

InputRated current

TypeBrand

Max. input consumption Max. current Starting current

Outdoor air flow Outdoor noise level Dimension(WxHxD) Packing dimension(WxHxD) Net/Gross weight Refrigerant type/quantity Design pressure

COU-9C

220~240/1/50

120003.5

13206.1

16208.327

RotaryMitsubishi

200050

880×540×305920×585×335

34/32680

2.7/0.7

6.35/ 12.7158

COU-12C

220~240/1/50

180005.3

17808.1

230011.638

RotaryMitsubishi

280053

880×540×305920×585×335

48/501000

2.7/0.7

6.35/ 12.7158

COU-18C

220~240/1/50

240007.1

233010.9

326014.864.7

RotaryGmcc3800

55925×700×366990×770×410

54/591100

2.7/0.7

9.52/ 15.882010

COU-24C

220~240/1/50

3600010.5398018.2

537024.6112

ScrollSanyo560060

1050×995×4001145×1120×475

92/1002200 2.7/0.7

9.52/ 19.052010

COU-36C

220~240/1/50

3600010.538006.8

51309.248

ScrollSanyo560060

1050×995×4001145×1120×475

92/1002200 2.7/0.7

9.52/ 19.052010

COU-36CS

380~415/3/50

523014

52309.5

732013.255

ScrollSanyo560060

1050×995×4001145×1120×475

92/1002050

2.7/0.7

2010

COU-48CS-A

380~415/3/50

4800014

52309.5

732013.255

ScrollSanyo610060

911×1330×400964×1445×402

88/992500

2.7/0.7

2010

COU-48CS

380~415/3/50

6000016

570010

760013.573

ScrollSanyo610060

911×1330×400964×1445×402

96/1073000

2.7/0.7

2010

COU-60CS

380~415/3/50

Liquid side/Gas side Max. pipe length Max. high drop

5

High

Optional

Standard

Page 7: 50Hz Light Commercial · 2019. 3. 18. · 2009 2011 The Chigo Air-cooled (Heat Pump) Chiller is included in the 2009 Energy-saving Product Catalog of National Commerce Domain The

50Hz Light Commercial Air Conditioner 50Hz Light Commercial Air Conditioner

87

Intelligent auto-swing function, three modes for choice.

6

Standard mode

Anti-point blow

Ceiling against mode

Multi protection and auto-restart function.11

Fire resistance design, the E-box with galvanized steel built-in body easy for maintenance.

Metal

10Easy and convenient installation and maintenance, washable filter design.

It is washable

7

Energy saving and healthy, adopting hydrophilic aluminum fins increasing heat-exchange efficiency.

condensing water and dust on aluminum fin surface

hydrophilic aluminun fin makes condensing water dispersing,and removing dust

9

R410A Heating Pump

Specification

Indoor Unit

Power supplyCapacity

Capacity

InputRated current

InputRated current

COP

EER

Capacity

Cooling

Heating

Physical data

Indoor noise level(Hi/Med/Lo)

Dimension(W×H×D)

Packing dimension(W×H×D)

Net/Gross weight

Refrigerant typePiping data

Liquid side/Gas sideDrainag pipe

Stuffing Quantity(set)

Indoor air flow(Hi/Med/Lo)

V/Ph/Hz

Btu/hKWWA

W/WBtu/hKWWA

W/W

m3/hdB(A)

Body(mm)Panel(mm)Body(mm)Panel(mm)Body(Kg)Panel(Kg) 

mmmmm2

40'HQ

180005.385

0.392.67

19800 5.8 85

0.393.27

700/580/48045/42/40

580×275×580650×30×650

745×375×675750×95×750

25/274/5

R410A

DN2520-35150

CCB-18HR1

220~240/1/50

R410A Cooling Only

Indoor Unit

Power supply Capacity

InputRated current

COP

Capacity

Cooling

Physical data

Indoor noise level(Hi/Med/Lo)

Dimension(W×H×D)

Packing dimension(W×H×D)

Net/Gross weight

Refrigerant typePiping data

Liquid side/Gas sideDrainag pipeApplication area

Application area

Stuffing Quantity(set)

Indoor air flow(Hi/Med/Lo)

V/Ph/Hz

Btu/hKWWA

W/W

m3/hdB(A)

Body(mm)Panel(mm)Body(mm)Panel(mm)Body(Kg)Panel(Kg) 

mmmmm2

40'HQ

180005.385

0.392.67

700/580/48045/42/40

580×275×580650×30×650

745×375×675750×95×750

25/274/5

R410A

DN2520-35150

CCB-18CR1

220~240/1/50

R22 Cooling Only

Indoor Unit

Power supply Capacity

InputRated current

COP

Capacity

Cooling

Physical data

Indoor noise level(Hi/Med/Lo)

Dimension(W×H×D)

Packing dimension(W×H×D)

Net/Gross weight

Refrigerant typePiping data

Liquid side/Gas sideDrainag pipeApplication areaStuffing Quantity(set)

Indoor air flow(Hi/Med/Lo)

V/Ph/Hz

Btu/hKWWA

W/W

m3/hdB(A)

Body(mm)Panel(mm)Body(mm)Panel(mm)Body (Kg)Panel (Kg)

mmmmm2

40'HQ

120003.5

13806.4

2.54

560/480/42045/42/40

580×275×580650×30×650

745×375×675750×95×750

25/274/5

R22

DN2515~25

150

CCB-12CR1

220~240/1/50

180005.3

18808.6

2.82

700/580/48048/43/38

580×275×580650×30×650

745×375×675750×95×750

25/274/5

R22

DN2520~35

150

CCB-18CR1

220~240/1/50

R22 Heating Pump

Model

Power supplyCapacity

Cooling

Capacity

InputRated current

EER

Capacity

InputRated current

EER

Heating

Physical data

Indoor noise level(Hi/Med/Lo)

Dimension(W×H×D)

Packing dimension(W×H×D)

Net/Gross weight

Refrigerant typePiping data

Liquid side/Gas side

Application areaDrainage pipe

Stuffing Quantity(set)

Indoor air flow(Hi/Med/Lo)

V/Ph/Hz

CCB-12H

220~240/1/50

CCB-18H

220~240/1/50

Built-in water pump, water head up to 700mm.8

700mm Btu/hKWWA

W/WBtu/hKWWA

W/W

m3/hdB(A)

Body(mm)Panel(mm)Body(mm)Panel(mm)Body (Kg)Panel (Kg)

mmmmm2

40'HQ

120003.5

13806.4

2.54 13000

3.812805.9

3.01

560/480/42045/42/40

580×275×580650×30×650745×375×675750×95×750

25/274/5

R22

DN2515~25

150

180005.3

18808.6

2.82 20000

5.8 1730

83.37

700/580/48048/43/38

580×275×580650×30×650

745×375×675750×95×750

25/274/5

R22

DN2520~35

150

R410A

R410A

Page 8: 50Hz Light Commercial · 2019. 3. 18. · 2009 2011 The Chigo Air-cooled (Heat Pump) Chiller is included in the 2009 Energy-saving Product Catalog of National Commerce Domain The

50Hz Light Commercial Air Conditioner 50Hz Light Commercial Air Conditioner

109

4-way Cassette Unit

Features:

Brand-new panel design

Simple, featly and voguish appearance suit for different requirements, it’ s mostly used for office, shopping center, restaurant, meeting room and etc..

1

18kBtu~60kBtu, standard type, 950*950

Ultra-thin body design, the min. height is only 230mm, save installation space.

5

4-way air flow, cold air can reach each corner of the room, providing a stable and comfortable environment.

2

Intelligent auto-swing function, three modes for choice.

6

Standard mode

High

Anti-point blow Ceiling against mode

Built-in water pump, water head up to 800mm.11

Multi protection and auto-restart function.9

Fresh air intake10

Fire resistance design, the E-box with galvanized steel built-in body easy for maintenance.

Metal

8

3 fan speed, meet for different requirement. 3

Easy and convenient installation and maintenance, washable filter design.

7

Three-dimensional centrifugal fan design.4

Energy saving and healthy, adopting hydrophilic aluminum fins increasing heat-exchange efficiency.

diffuser

three-dimensionalspiral fan blade

condensing water and dust on aluminum fin surface

hydrophilic aluminun fin makes condensing water dispersing,and removing dust

12

18k~60k Btu/h

Optional

Standard

Page 9: 50Hz Light Commercial · 2019. 3. 18. · 2009 2011 The Chigo Air-cooled (Heat Pump) Chiller is included in the 2009 Energy-saving Product Catalog of National Commerce Domain The

R410A Heating Pump

Indoor Unit

Power supplyCapacity

Capacity

InputRated current

InputRated current

COP

EER

Capacity

Cooling

Heating

Physical data

Indoor noise level(Hi/Med/Lo)

Dimension(W×H×D)

Packing dimension(W×H×D)

Net/Gross weight

Refrigerant typePiping data

Liquid side/Gas sideDrainag pipeApplication areaStuffing Quantity(Set)

Indoor air flow(Hi/Med/Lo)

V/Ph/Hz

Btu/hKW

Btu/hKWWA

W

W/W

W/W

A

dB(A)Body(mm)Pane(mm)

mmmmm2

220-240/1/50

18000

640.292.70

19800

640.293.31

810/720/64039/36/35

840x230x840950x50x950

Body(kg)Pane(kg)

26/325/7

R410A

DN25 DN25 DN25 DN25 DN2520-35

90

5.8

5.3

CCA-18HR1

m3/h

40’ HQ

220-240/1/50

24000

1200.552.82

26400

1200.553.51

1100/920/75044/41/39

840x230x840950x50x950

28/325/7

R410A

28-5090

7.8

7.1

CCA-24HR1

220-240/1/50

36000

1600.732.71

39600

1600.733.31

1600/1300/110047/44/42

840x285x840950x50x950

31/355/7

R410A

40-7060 60 60

11.5

10.5

CCA-36HR1

220-240/1/50

48000

1800.822.70

52800

1800.822.92

1900/1550/130048/47/44

840x285x840950x50x950

31/355/7

R410A

55-95

15.4

14

CCA-48HR1

220-240/1/50

60000

1800.822.72

66000

1800.822.78

1900/1550/130048/47/44

840x285x840950x50x950

31/355/7

R410A

60-105

16.6

16

CCA-60HR1

Body(mm)Pane(mm)

920x310x920 920x310x920 920x375x920 920x375x920 920x375x9201030x105x1030 1030x105x1030 1030x105x1030 1030x105x1030 1030x105x1030

R410A Cooling Only

Indoor Unit

Power supply

Capacity

Capacity

InputRated current

EER

Cooling

Physical data

Indoor noise level(Hi/Med/Lo)

Dimension(W×H×D)

Packing dimension(W×H×D)

Net/Gross weight

Refrigerant typePiping data

Liquid side/Gas sideDrainag pipeApplication areaStuffing Quantity(Set)

Indoor air flow(Hi/Med/Lo)

V/Ph/Hz

Btu/hKWW

W/WA

dB(A)Body(mm)Pane(mm)

mmmmm2

180005.364

0.292.70

810/720/64039/36/35

840×230×840950×50×950

920×310×9201030×105×1030

26/325/7

R410A

DN2520-35

90

240007.11200.552.82

1100/920/75044/41/39

840×230×840950×50×950

920×310×9201030×105×1030

28/325/7

R410A

DN2528-50

90

3600010.51600.732.71

1600/1300/110047/44/42

840×285×840950×50×950

920×375×9201030×105×1030

31/355/7

R410A

DN2540-70

60

4800014

1800.822.70

1900/1550/130048/47/44

840×285×840950×50×950

920×375×9201030×105×1030

31/355/7

R410A

DN2555~95

60

6000016

1800.822.72

1900/1550/130048/47/44

840×285×840950×50×950

920×375×9201030×105×1030

31/355/7

R410A

DN2560~105

60

Body(kg)Pane(kg)

CCA-18CR1

220-240/1/50

CCA-24CR1

220-240/1/50

CCA-36CR1

220-240/1/50

CCA-48CR1

220-240/1/50

CCA-60CR1

220-240/1/50

m3/h

40’ HQ

Body(mm)Pane(mm)

R22 Heating Pump

Indoor Unit

Power supplyCapacity

Capacity

InputRated current

InputRated current

COP

EER

Capacity

Cooling

Heating

Physical data

Indoor noise level(Hi/Med/Lo)

Dimension(W×H×D)

Packing dimension(W×H×D)

Net/Gross weight

Refrigerant typePiping data

Liquid side/Gas sideDrainag pipeApplication areaStuffing Quantity(Set)

Indoor air flow(Hi/Med/Lo)

V/Ph/Hz

Btu/hKW

Btu/hKWWA

W

W/W

W/W

A

dB(A)Body(mm)Pane(mm)

mmmmm2

Body(kg)Pane(kg)

CCA-18H

220~240/1/50

m3/h

40’ HQ

180005.3

18808.6

2.82 20000

5.8 1730

83.37

810/700/58048/45/43

840×230×840950×50×950

920×310×9201030×105×1030

26/325/7

R22

DN2520~35

90

CCA-24H

220~240/1/50

240007.1

248011.62.86

260007.8

229010.93.41

1200/1050/90048/46/44

840×230×840950×50×950

920×310×9201030×105×1030

28/325/7

R22

9.52/15.88DN2528~50

90

CCA-36H

220~240/1/50

3600010.539607.1

2.65 3900011.5 38406.9

3.01

1700/1500/120048/46/44

840×285×840950×50×950

920×375×9201030×105×1030

31/355/7

R22

DN2540~70

60

CCA-48H

220~240/1/50

4800014

53909.8

2.60 5200015.4 52909.6

2.91

1700/1500/120052/48/45

840×285×840950×50×950920×375×920

1030×105×103032/36

5/7 R22

DN2555~95

60

CCA-60H

220~240/1/50

6000016

588010.32.72 6000016.6 598010.52.68

1900/1600/130052/48/45

840×285×840950×50×950920×375×920

1030×105×103031/355/7

R22

DN2560~105

60

Body(mm)Pane(mm)

R22 Cooling Only

Indoor Unit

Power supply

Capacity

Capacity

InputRated current

EER

Cooling

Physical data

Indoor noise level(Hi/Med/Lo)

Dimension(W×H×D)

Packing dimension(W×H×D)

Net/Gross weight

Refrigerant typePiping data

Liquid side/Gas sideDrainag pipeApplication areaStuffing Quantity(Set)

Indoor air flow(Hi/Med/Lo)

V/Ph/Hz

Btu/hKWW

W/WA

dB(A)Body(mm)Pane(mm)

mmmmm2

180005.3

18808.6

2.82

810/700/58048/45/43

840×230×840950×50×950

920×310×9201030×105×1030

26/325/7

R22

DN2520~35

90

240007.1

248011.62.86

1200/1050/90048/46/44

840×230×840950×50×950

920×310×9201030×105×1030

28/325/7

R22

9.52/15.88DN2528~50

90

3600010.539607.1

2.65

1700/1500/120048/46/44

840×285×840950×50×950

920×375×9201030×105×1030

31/355/7

R22

DN2540~70

60

4800014

54109.8

2.59

1900/1600/130052/48/45

840×285×840950×50×950

920×375×9201030×105×1030

32/365/7

R22

DN2555~95

60

6000016

588010.32.72

1900/1600/130052/48/45

840×285×840950×50×950

920×375×9201030×105×1030

31/355/7

R22

DN2560~105

60

Body(kg)Pane(kg)

CCA-18C

220~240/1/50

CCA-24C

220~240/1/50

CCA-36C

220~240/1/50

CCA-48C

220~240/1/50

CCA-60C

220~240/1/50

m3/h

40’ HQ

Body(mm)Pane(mm)

R410A

R410A

1211

50Hz Light Commercial Air Conditioner 50Hz Light Commercial Air Conditioner

Page 10: 50Hz Light Commercial · 2019. 3. 18. · 2009 2011 The Chigo Air-cooled (Heat Pump) Chiller is included in the 2009 Energy-saving Product Catalog of National Commerce Domain The

R410A Heating Pump

Indoor Unit

Power supply

Capacity

Capacity

InputRated current

InputRated current

COP

EER

Capacity

Cooling

Heating

Physical data

Indoor noise level(Hi/Med/Lo)Dimension(W×H×D) Packing dimension(W×H×D)

Net/Gross weightRefrigerant typePiping data

Liquid side/Gas sideDrainag pipeApplication areaStuffing Quantity(Set)

Indoor air flow(Hi/Med/Lo)

V/Ph/Hz

Btu/hKW

Btu/hKWW

A

W

W/W

W/W

A

dB(A)

mm

mm

mmmmm2

220-240/1/50

18000

650.3

2.719800

65

0.33.3

790/670/54051/47/43

880x635x203

970x711x301kg 26/32

R410A

DN2520-35150

5.8

5.3

CUA-18HR1

m3/h

40’ HQ

220-240/1/50

24000

1500.68

2.7826400

150

0.683.47

1100/860/74047/48/43

1245x680x247

1325x770x32528/32

R410A

DN2528-50

95

7.8

7.1

CUA-24HR1

220-240/1/50

36000

3001.36

2.6239600

300

1.363.19

1700/1300/110050/46/43

1245x680x247

1325x770x32531/35

R410A

DN2540-70

70

11.5

10.5

CUA-36HR1

220-240/1/50

48000

3301.5

2.6352800

330

1.52.84

2300/1900/150055/52/50

1670x680x247 1670x680x247

1750x770x325 1750x770x32531/35

R410A

DN2555-95

60

15.4

14

CUA-48HR1

220-240/1/50

60000

3301.5

2.6566000

330

1.52.71

2300/1900/160055/52/50

31/35

R410A

DN2560-105

60

16.6

16

CUA-60HR1

R410A Cooling Only

Model

Indoor Power supply

Capacity

Capacity

InputRated current

EER

Cooling

Physical data

Indoor noise level(Hi/Med/Lo)Dimension(W×H×D) Packing dimension(W×H×D) Net/Gross weightRefrigerant typePiping data

Liquid side/Gas sideDrainag pipeApplication areaStuffing Quantity(Set)

Indoor air flow(Hi/Med/Lo)

V/Ph/Hz

Btu/hKWW

W/W

A

dB(A)

mm

mm

mmmmm2

220-240/1/50

180005.3650.32.7

790/670/54051/47/43

880×635×203970×711×301

30/32R410A

DN2520-35150

240007.11500.682.78

1100/860/74047/45/43

1245×680×2471325×770×325

35/41R410A

DN2528-50

95

3600010.53001.362.62

1700/1300/110050/46/43

1245×680×2471325×770×325

37/43R410A

DN2540-70

70

48000143301.52.63

2300/1900/150055/52/50

1670×680×2471750×770×325

47/54R410A

DN2555~95

60

60000163301.52.65

2300/1900/160055/52/50

1670×680×2471750×770×325

47/54R410A

DN2560~105

60

kg

CUA-18CR1

m3/h

40’ HQ

220-240/1/50

CUA-24CR1

220-240/1/50

CUA-36CR1

220-240/1/50

CUA-48CR1

220-240/1/50

CUA-60CR1

00000000000000000000000

Floor & Ceiling Unit

3

Features:

Flexible installation, ceiling suspended and floor standing.

Auto-swing function, built-in two louver motor, vertical and horizontal air-flow adjustment.

1

Washable air filter

5 Adopting waterproof plastic f i lm on water col lector, avoiding water leakage.

4 Built-in with water pump,pumping head is up to 1200mm(Option).

6 Self-diagnostic function and multi protection.

7 Auto-restart function.

astic tor,

18k~60k Btu/h

2

Optional

Standard

R410A

R410A

1413

50Hz Light Commercial Air Conditioner 50Hz Light Commercial Air Conditioner

Page 11: 50Hz Light Commercial · 2019. 3. 18. · 2009 2011 The Chigo Air-cooled (Heat Pump) Chiller is included in the 2009 Energy-saving Product Catalog of National Commerce Domain The

00000000000000000000000

Low ESP Ducted Unit

2

Features:

Ultra-thin body design.

Three fan speed, meeting different requirements.

1

Multi protection and auto-restart function.3

5 Body-side is E-box, convenient for installation and maintenance.

4 Adopting aviation centrifugal fans, and CFD technology design, increasing air-volume and decreasing noise level, noise level only 29dB(A) for Low ESP Ducted Unit .

12k-24k Btu/h

R22 Heating Pump

Indoor Unit

Power supplyCapacity

Capacity

InputRated current

InputRated current

COP

EER

Capacity

Cooling

Heating

V/Ph/Hz

Btu/hKW

Btu/hKWWA

W

W/W

W/W

A

dB(A)

mmmmm2

CUA-18H

220~240/1/50

m3/h

40’ HQ

180005.3

19108.7

2.77 200005.8 17608.1

3.31

790/670/54052/48/44

880×635×203970×711×301

30/32 R22

DN2520-35 

150

mmmmKg

CUA-24H

220~240/1/50

240007.1

248011.62.86

260007.8 229010.93.41

1300/1100/90048/43/39

1245×680×2351325×770×325

35/41 R22

DN25 28-50

95

CUA-36H

220~240/1/50

3600010.540407.2

2.60 3900011.5 3920

72.95

1500/1300/110050/47/44

1245×680×2351325×770×325

37/43 R22

DN2540~70

70

CUA-48H

220~240/1/50

4800014

556010.12.53

5200015.4 54609.9

2.79

2300/1900/160052/48/45

1670×680×2351750×770×325

47/54 R22

DN2555~95

60

CUA-60H

220~240/1/50

6000016

603010.62.65

6000016.6 613010.82.61

2300/1900/160052/48/45

1670×680×2351750×770×325

47/54 R22

DN2560~105

60

Physical data

Piping data

Liquid side/Gas side

Application areaDrainage pipe

Stuffing Quantity(Set)

Indoor air flow(Hi/Med/Lo)Indoor noise level(Hi/Med/Lo)Dimension(W×H×D) Packing dimension(W×H×D) Net/Gross weightRefrigerant type

R22 Cooling Only

Indoor Unit

Power supplyCapacity

InputRated current

COP

Capacity

Cooling

V/Ph/Hz

Btu/hKWWA

W/W

dB(A)

mmmmm2

CUA-18C

220~240/1/50

m3/h

40’ HQ

180005.3

19108.7

2.77

790/670/54048/43/38

880×635×203970×711×301

30/32 R22

DN2520-35 

150

mmmmKg

CUA-24C

220~240/1/50

240007.1

248011.62.86

1300/1100/90048/43/39

1245×680×2351325×770×325

35/41 R22

DN25 28-50

95

CUA-36C

220~240/1/50

3600010.540407.2

2.60

1500/1300/110050/47/44

1245×680×2351325×770×325

37/43 R22

DN2540~70

70

CUA-48C

220~240/1/50

4800014

556010.12.53

2300/1900/160052/48/45

1670×680×2351750×770×325

47/54 R22

DN2555~95

60

CUA-60C

220~240/1/50

6000016

603010.62.65

2300/1900/160052/48/45

1670×680×2351750×770×325

47/54 R22

DN2560~105

60

Physical data

Piping data

Liquid side/Gas side

Application areaDrainage pipe

Stuffing Quantity(Set)

Indoor air flow(Hi/Med/Lo)Indoor noise level(Hi/Med/Lo)Dimension(W×H×D) Packing dimension(W×H×D) Net/Gross weightRefrigerant type

Optional

Standard

1615

50Hz Light Commercial Air Conditioner 50Hz Light Commercial Air Conditioner

Page 12: 50Hz Light Commercial · 2019. 3. 18. · 2009 2011 The Chigo Air-cooled (Heat Pump) Chiller is included in the 2009 Energy-saving Product Catalog of National Commerce Domain The

R410A Heating Pump

Indoor Unit

Power supply

Capacity

Capacity

InputRated current

Input

Rated current

COP

EER

Capacity

Cooling

Heating

Physical data

Static Pressure

Dimension(W×H×D)

Packing(W×H×D)

Net/Gross weightRefrigerant type

Piping data

Liquid side/Gas sideDrainag pipe

Application area

Stuffing quantity(Set)

Indoor air flow(Hi/Med/Lo)

V/Ph/Hz

Btu/h

KW

Btu/hKWW

A

W

W/W

W/W

A

Pa

mm

mm

kg

mm

mm

m2

220-240/1/50

18000

5.3

70

0.32

2.69

19800

5.8

70

0.3

3.30

730/600/500

10

42/31/26

1204×181×510

1330×250×605

21/25

R410A

DN25

20-35

130

Indoor noise level(Hi/Med/Lo) dB(A)

CTA-18HR1

220-240/1/50

24000

7.1

150

0.68

2.78

26400

7.8

150

0.7

3.47

1020/860/740

10

43/32/28

1532×181×510

1650×250×605

26/30

R410A

DN25

28-50

120

CTA-24HR1

m3/h

40’HQ

R22 Heating Pump

Indoor Unit

Power supply

Capacity

Capacity

InputRated current

Input

Rated current

COP

EER

Capacity

Cooling

Heating

Physical data

Static Pressure

Dimension(W×H×D)

Packing(W×H×D)

Net/Gross weightRefrigerant type

Piping data

Liquid side/Gas sideDrainag pipe

Application area

Stuffing quantity(Set)

Indoor air flow(Hi/Med/Lo)

V/Ph/Hz

Btu/h

KW

Btu/hKWW

A

W

W/W

W/W

A

Pa

mm

mm

kg

mm

mm

m2

220-240/1/50

9000

2.6

1010

4.7

2.57

10000

2.9

940

4.3

3.04

420/370/300

0/10

40/35/29

926×181×510

1055×250×605

17/20

R22

DN25

10~20

140

Indoor noise level(Hi/Med/Lo) dB(A)

CTA-9H

220-240/1/50

12000

3.5

1380

6.4

2.54

13000

3.8

1280

5.9

3.01

500/400/350

0/10

46/40/35

926×181×510

1055×250×605

17/20

R22

DN25

15~25

140

CTA-12H

220-240/1/50

18000

5.3

1850

8.4

2.86

20000

5.8

1700

7.8

3.43

730/600/500

0/10

46/42/37

1204×181×510

1330×250×605

21/25

R22

DN25

20~35

130

CTA-18H

220-240/1/50

24000

7.1

2460

11.3

2.89

26000

7.8

2270

10.8

3.44

1020/860/740

0/10

48/43/38

1532×181×510

1645×250×605

26/30

R22

DN25

28~50

120

CTA-24H

m3/h

40’HQ

Indoor Unit

Power supply

Capacity

Capacity

InputRated current

EER

Cooling

Physical data

Static Pressure

Dimension(W×H×D)

Packing(W×H×D)

Net/Gross weightRefrigerant type

Piping data

Liquid side/Gas sideDrainag pipe

Application area

Stuffing quantity(Set)

Indoor air flow(Hi/Med/Lo)

V/Ph/Hz

Btu/h

KW

W

W/W

A

Pa

mm

mm

kg

mm

mm

m2

220-240/1/50

18000

5.3

70

0.32

2.69

730/600/500

10

42/31/26

1204×181×510

1330×250×605

21/25

R410A

DN25

20-35

130

Indoor noise level(Hi/Med/Lo) dB(A)

CTA-18CR1

220-240/1/50

24000

7.1

150

0.68

2.78

1020/860/740

10

43/32/28

1532×181×510

1650×250×605

26/30

R410A

DN25

28~50

120

CTA-24CR1

m3/h

40’HQ

Medium ESP Ducted Unit

Features:

Ultra-thin body design.

Medium ESP Type

1

2 Adopting aviation centrifugal fans, and CFD technology design, increasing air-volume and decreasing noise level.

3 Filter can be taken out easily for clean maintenance.

Multi protection and auto-restart function.7

4 Body-side is E-box, convenient for installation and maintenance.

5 Three fan speed, meeting different requirements.

6 50Pa ESP design, duct connected installation meeting different room structure.

R410A Cooling Only

Indoor Unit

Power supply

Capacity

Capacity

InputRated current

EER

Cooling

Physical data

Static Pressure

Dimension(W×H×D)

Packing(W×H×D)

Net/Gross weightRefrigerant type

Piping data

Liquid side/Gas sideDrainag pipe

Application area

Stuffing quantity(Set)

Indoor air flow(Hi/Med/Lo)

V/Ph/Hz

Btu/h

KW

W

W/W

A

Pa

mm

mm

kg

mm

mm

m2

220-240/1/50

9000

2.6

1010

4.7

2.57

420/370/300

0/10

40/35/29

926×181×510

1055×250×605

19/16

R22

DN25

10~20

140

Indoor noise level(Hi/Med/Lo) dB(A)

CTA-9C

220-240/1/50

12000

3.5

1380

6.4

2.54

500/400/350

0/10

46/40/35

926×181×510

1055×250×605

16.5/19.5

R22

DN25

15~25

140

CTA-12C

220-240/1/50

18000

5.3

1850

8.4

2.86

730/600/500

0/10

46/42/37

1204×181×510

1330×250×605

20/24

R22

DN25

20~35

130

CTA-18C

220-240/1/50

24000

7.1

2460

11.3

2.89

1020/860/740

0/10

48/43/38

1532×181×510

1645×250×605

26/30

R22

DN25

28~50

120

CTA-24C

m3/h

40’HQ

R22 Cooling Only

R410A

R410A

24k~60k Btu/h Optional

Standard

1817

50Hz Light Commercial Air Conditioner 50Hz Light Commercial Air Conditioner

Page 13: 50Hz Light Commercial · 2019. 3. 18. · 2009 2011 The Chigo Air-cooled (Heat Pump) Chiller is included in the 2009 Energy-saving Product Catalog of National Commerce Domain The

R22 Heating Pump

R22 Cooling Only

R410A Heating Pump

Indoor Unit

Power supply

Capacity

Capacity

InputRated current

Input

Rated currentCOP

EER

Capacity

Cooling

Heating

Physical data

Static Pressure

Dimension(W×H×D)

Packing dimension(W×H×D) Net/Gross weightRefrigerant typePiping data

Liquid side/Gas sideDrainag pipe

Application areaStuffing quantity(Set)

Indoor air flow(Hi/Med/Lo)

V/Ph/Hz

Btu/hKW

Btu/hKWW

A

W

W/W

W/W

A

Pa

mm

mmkg

mmmmm2

220-240/1/50

240007.12501.142.68

26400 7.8 2501.163.32

1200/860/74050

46/42/381189×260×6631255×330×730

32/36R410A

DN2528-50100

Indoor noise level(Hi/Med/Lo) dB(A)

CTB-24HR1

220-240/1/50

3600010.53401.552.59

39600 11.5 3401.6

3.18

1900/1500/120050

48/43/381425×260×6631490×330×730

44/48R410A

DN2540-70

70

CTB-36HR1

220-240/1/50

4800014

3401.552.62

52800 15.4 3401.6

2.83

2000/1600/130050

48/43/381425×260×6631490×330×730

44/48R410A

DN2555-95

60

CTB-48HR1

220-240/1/50

6000016

3401.552.65

66000 16.6 3401.6

2.72

2000/1600/130050

48/43/381425×260×6631490×330×730

44/48R410A

DN2560-105

60

CTB-60HR1

m3/h

40’ HQ

Indoor Unit

Power supply

Capacity

Capacity

InputRated current

Input

Rated currentCOP

EER

Capacity

Cooling

Heating

Physical data

Static Pressure

Dimension(W×H×D)

Packing dimension(W×H×D) Net/Gross weightRefrigerant typePiping data

Liquid side/Gas sideDrainag pipe

Application areaStuffing quantity(Set)

Indoor air flow(Hi/Med/Lo)

V/Ph/Hz

Btu/hKW

Btu/hKWW

A

W

W/W

W/W

A

Pa

mm

mmkg

mmmmm2

220-240/1/50

240007.1

252011.82.82

260007.8

233011.13.35

1150/1000/82050

48/44/401190×260×6631255×330×730

32/36 R22

DN2528-50100

Indoor noise level(Hi/Med/Lo) dB(A)

CTB-24H

220-240/1/50

3600010.541407.4

2.54 3900011.5 40207.2

2.87

1900/1600/130050

50/45/401425×260×6631490×330×730

44/48 R22

DN2540-70

70

CTB-36H

220-240/1/50

4800014

557010.12.51

5200015.4 54709.9

2.82

2000/1700/140050

50/45/401425×260×6631490×330×730

46/50 R22

DN2555-95

60

CTB-48H

220-240/1/50

6000016

604010.62.65 6000016.6 614010.82.61

2000/1700/140050

50/45/401425×260×6631490×330×730

46/50 R22

DN2560-105

60

CTB-60H

m3/h

40’ HQ

R410A Cooling Only

Indoor Unit

Power supply

Capacity

Capacity

InputRated current

EER

Cooling

Physical data

Static Pressure

Dimension(W×H×D)

Packing dimension(W×H×D) Net/Gross weightRefrigerant typePiping data

Liquid side/Gas sideDrainag pipeApplication area

Stuffing quantity(Set)

Indoor air flow(Hi/Med/Lo)

V/Ph/Hz

Btu/hKWW

W/W

A

Pa

mm

mmkg

mmmmm2

220-240/1/50

240007.12501.142.68

1200/860/74050

46/42/381189×260×6631255×330×730

32/36R410A

DN2528-50100

Indoor noise level(Hi/Med/Lo) dB(A)

CTB-24CR1

220-240/1/50

3600010.53401.552.59

1900/1500/120050

48/43/381425×260×6631490×330×730

44/48R410A

DN2540-70

70

CTB-36CR1

220-240/1/50

4800014

3401.552.62

2000/1600/130050

48/43/381425×260×6631490×330×730

44/48R410A

DN2555~95

60

CTB-48CR1

220-240/1/50

6000016

3401.552.65

2000/1600/130050

48/43/381425×260×6631490×330×730

44/48R410A

DN2560~105

60

CTB-60CR1

m3/h

40’ HQ

Indoor Unit

Power supply

Capacity

Capacity

InputRated current

EER

Cooling

Physical data

Static Pressure

Dimension(W×H×D)

Packing dimension(W×H×D) Net/Gross weightRefrigerant typePiping data

Liquid side/Gas sideDrainag pipeApplication area

Stuffing quantity(Set)

Indoor air flow(Hi/Med/Lo)

V/Ph/Hz

Btu/hKWW

W/W

A

Pa

mm

mmkg

mmmmm2

220-240/1/50

240007.1

252011.82.82

1150/1000/82050

48/44/401190×260×6631255×330×730

32/36 R22

DN2528-50100

Indoor noise level(Hi/Med/Lo) dB(A)

CTB-24C

220-240/1/50

3600010.541407.4

2.54

1900/1600/130050

50/45/401425×260×6631490×330×730

44/48 R22

DN2540-70

70

CTB-36C

220-240/1/50

4800014

557010.12.51

2000/1700/140050

50/45/401425×260×6631490×330×730

46/50 R22

DN2555-95

60

CTB-48C

220-240/1/50

6000016

604010.62.65

2000/1700/140050

50/45/401425×260×6631490×330×730

46/50 R22

DN2560-105

60

CTB-60C

m3/h

40’ HQ

R410A

R410A

2019

50Hz Light Commercial Air Conditioner 50Hz Light Commercial Air Conditioner

Page 14: 50Hz Light Commercial · 2019. 3. 18. · 2009 2011 The Chigo Air-cooled (Heat Pump) Chiller is included in the 2009 Energy-saving Product Catalog of National Commerce Domain The

50Hz Light Commercial Air Conditioner 50Hz Light Commercial Air Conditioner

2221

R22 Heating PumpR410A Heating Pump

Indoor Unit

power supply

Capacity

Cooling

Heating

Capacity

InputRated current

EER

Capacity

Input

Rated currentCOP

Physical data

Indoor air flow(Hi/Med/Lo)Static PressureIndoor noise level(Hi/Med/Lo)Dimension(WxHxD)Packing(WxHxD)

Piping data

Liquid side/Gas side Drainage pipe

V/Ph/Hz

Btu/h

WA

WW

m3/hpa

dB(A)mmmm

Kg

mmmm

Application area m2

40'HQ

30 30

60/64 60/64

48000 60000

KW

Btu/h

W

AWW

KW

220-240/1/50 208-230/60/1

CTH-48HR1 CTH-60HR1

Net/Gross weightRefrigerant type

Stuffing Quantity(Set)

66000

Indoor Unit

power supply

Capacity

Cooling

Heating

Capacity

InputRated current

EER

Capacity

Input

Rated currentCOP

Physical data

Indoor air flow(Hi/Med/Lo)Static PressureIndoor noise level(Hi/Med/Lo)Dimension(WxHxD)Packing(WxHxD)

Piping data

Liquid side/Gas side Drainage pipe

V/Ph/Hz

Btu/h

WA

WW

m3/hpa

dB(A)mmmm

Kg

mmmm

Application area m2

40'HQ

48000

R22

60000

6200

60000

6300

R22

KW

Btu/h

W

AWW

KW

220-240/1/50 208-230/60/1

CTH-48H CTH-60H

Net/Gross weightRefrigerant type

Stuffing Quantity(Set)

High ESP Ducted Type Unit

Features:

Centrifugal fan, low noise and big airflow.1

3

Standard ESP is 120Pa, flexible air duct installtion.2

Max.refrigerant pipe length is 50m. Max.difference in height 20m.

4 Standard for wired controllr; optional for wireless controller.

R22 Cooling Only

Indoor Unit

power supply

Capacity

Physical data

Piping data

Liquid side/Gas side

Drainage pipe

Application area

Stuffing Quantity(Set)

Cooling

V/Ph/Hz

Btu/h

KW

W

A

W/W

m3/h

Pa

dB(A)

mm

mm

Kg

mm

mm

m2

40'HQ

Indoor air flow(Hi/Med/Lo)

Static Pressure

Indoor noise level(Hi/Med/Lo)

Dimension(WxHxD)

Packing(WxHxD)

Net/Gross weight

Refrigerant type

48000

60/64

60000

60/64

CTH-48CR1

220-240/1/50

CTH-60CR1

220-240/1/50

R410A Cooling Only

Input

Rated current

EER

Capaci

Indoor Unit

power supply

Capacity

Physical data

Piping data

Liquid side/Gas side

Drainage pipe

Application area

Stuffing Quantity(Set)

Cooling

V/Ph/Hz

Btu/h

KW

W

A

W/W

m3/h

Pa

dB(A)

mm

mm

Kg

mm

m2

40'HQ

Indoor air flow(Hi/Med/Lo)

Static Pressure

Indoor noise level(Hi/Med/Lo)

Dimension(WxHxD)

Packing(WxHxD)

Net/Gross weight

Refrigerant type

48000

44/48

R22

60000

6200

44/48

R22

CTH-48C

220-240/1/50

CTH-60C

220-240/1/50

Input

Rated current

EER

Capaci

48k~60k Btu/h Optional

Standard

R410A

R410A

Page 15: 50Hz Light Commercial · 2019. 3. 18. · 2009 2011 The Chigo Air-cooled (Heat Pump) Chiller is included in the 2009 Energy-saving Product Catalog of National Commerce Domain The

Famous scroll compressor with quick reactivity, stronger power and operation stable.Anti-attenuation design and better low-temperature heating performance.

1

Features:

New panel and Plastics Safe guard of outdoor unit.

2

The diameter of globe valve is DN8mm.3

50Hz Light Commercial Air Conditioner 50Hz Light Commercial Air Conditioner

2423

R22 Cooling Only

Floor-standing Outdoor Unit

96k Btu/h70k Btu/h

R22 Heating Pump

Outdoor Unit

power supply

Capacity

Cooling

Heating

Capacity

Input

Capacity

InputPhysical data

Outdoor air flowOutdoor noise levelNet dimension (WxHxD)

Packing dimension(WxHxD)

Net weight

Refrigerant Type

Charge

Piping data

V/Ph/Hz

Btu/h

WKW

KW

m3/h

mmdB(A)

mmkg

kg

g

mm

mmm

m

m2

20

22

8000

R22

20

-

28

30

68

208

223

R22

20

-

Btu/h

W

380-415/3/50 380-415/3/50

COW-70HS COW-96HS

Gross weight

Liquid sideGas side

Application area

Outdoor Unit

power supply

Capacity

Cooling

Capacity

Input

EER

Physical data

Outdoor air flowOutdoor noise levelNet dimension (WxHxD)

Packing dimension(WxHxD)

Net weight

Refrigerant Type

Charge

Piping data

V/Ph/Hz

Btu/h

WW/W

KW

m3/h

mmdB(A)

mmkg

kg

g

mm

mmm

m

m2

20

8000

R22

20

-

28

68

208

223

R22

20

-

380-415/3/50 380-415/3/50

COW-70CS C0W-96CS

Gross weight

Liquid sideGas side

Application area

Page 16: 50Hz Light Commercial · 2019. 3. 18. · 2009 2011 The Chigo Air-cooled (Heat Pump) Chiller is included in the 2009 Energy-saving Product Catalog of National Commerce Domain The

50Hz Light Commercial Air Conditioner 50Hz Light Commercial Air Conditioner

2625

R22 Heating Pump

Indoor UnitPower supply

Capacity

Cooling

Heating

Capacity

InputEER

Capacity

Input

COPPhysical data

Piping data

V/Ph/Hz

Btu/h

WKW

m3/h

mmdB(A)

mmkg

kg

mm

mmm

m

mmm2

40'HQ

28

30

4000/3600/3300

20

Btu/h

W/W

W/W

W

KW

220~240/1/50 220~240/1/50

CFAi-70H CFAi-96H

Liquid sideGas side

Drainage pipe Application areaStuffing Quantity(Set)

Indoor air flow (Hi/Med/Lo) (0 pa)Indoor noise level (Hi/Med/Lo)Net dimension (WxHxD)Packing dimension(WxHxD)Net weightGross weight

20

22

20

Indoor Unit

Power supply

Capacity

Cooling

V/ph/Hz

Btu/hKWW

W/W

m3/hdB(A)mmmmkgkg 

mmmmmm

mmm2

40'HQ

20

20

28

4000/3600/3300

20

CFAi-70C

220~240/1/50

CFAi-96C

220~240/1/50

R22 Cooling Only

Capacity

Input

EERPhysical data

Indoor air flow (Hi/Med/Lo) (0 pa)Indoor noise level (Hi/Med/Lo)Net dimension (WxHxD)Packing dimension(WxHxD)Net weightGross weightPiping data

Liquid sideGas side

Drainage pipe Application area Stuffing Quantity(Set)

Features:

70k Btu/h 96k Btu/h

New air f low system, Larger heat-exchanging area, Higher efficiency of the evaporator.

Brand-new panel design Sinple, featly and voguish appearance suit different requirements.it’ s mostly used for office,shopping center,restaurant,meeting room andetc..Aviation centrifugal fan.Double CFD technology design,increasing air-volume and decreaing noise level.

Floor-standing Indoor Unit

2

1

3

765

Standard for horizontal air flow, cold air can reach each corner of the room, providing a stable and comfortable environment.

Standard

Optional

Optional control pa- nel,meeting diffe- rent requirements.

4 Plastics centrifugal fan, suitable blades, low noise and big flow.

Sl im body, the depth of the body is only 380mm.

Easy and convenient instal lat ion and maintenance.

Standard

Page 17: 50Hz Light Commercial · 2019. 3. 18. · 2009 2011 The Chigo Air-cooled (Heat Pump) Chiller is included in the 2009 Energy-saving Product Catalog of National Commerce Domain The

50Hz Light Commercial Air Conditioner 50Hz Light Commercial Air Conditioner

2827

R22 Heating Pump

Outdoor Unitpower supply

Capacity

Cooling

Heating

Physical data

Piping data

V/Ph/Hz

m3/h

mmdB(A)

mmkg

g

mm m m

COW-96HZ

380~415V/3/50

Liquid side/ Gas side

Outdoor air flow Outdoor noise level Net dimension(WxHxD) Packing dimension (WxHxD)Net/Gross weight Refrigerant type(R22)

28

30

68

208/223

20 

COW-110HZ

380~415/3/50

32

34

68

20

Capacity Input Rated current Capacity Input Rated current

Btu/h KW W A

Btu/h KW W A

Outdoor Unit

Power supply

Capacity

Cooling

V/Ph/Hz

Btu/h KW W A

m3/h dB(A) mm mm kg g

mm m m

28

68

208/223

20

COW-96CZ

380~415V/3/50

32

68

20

COW-110CZ

380~415/3/50

R22 Cooling Only

Capacity

Rated current Input

Physical data

Physical data

Outdoor air flow Outdoor noise level Net dimension(WxHxD) Packing dimension (WxHxD) Net/Gross weight Refrigerant type(R22)

Liquid side/ Gas side

Features:

New panel and Plastics Safe guard of outdoor unit.

2

The diameter of globe valve is DN8mm.3

Famous scroll compressor with quick reactivity, stronger power and operation stable.Anti-attenuation design and better low-temperature heating performance.

1

96K&110K Btu/h High ESP Ducted Outdoor Unit

96k/110k Btu/h

Page 18: 50Hz Light Commercial · 2019. 3. 18. · 2009 2011 The Chigo Air-cooled (Heat Pump) Chiller is included in the 2009 Energy-saving Product Catalog of National Commerce Domain The

50Hz Light Commercial Air Conditioner 50Hz Light Commercial Air Conditioner

3029

Heating Pump

Indoor Unit

power supply

Capacity

Cooling

Heating

Capacity

EER

Capacity

COP

Physical data

Piping data

V/Ph/Hz

Btu/h

KW

m3/h

dB(A)

Pa

mm

mm

kg

Btu/h

W/W

W/W

KW

Liquid side/ Gas side

Ambient temp

Application area

Stuffing Quantity

Indoor air flow (Hi/Med/Lo)

Static Pressure

Indoor noise level(Hi/Med/Lo)

Dimension (WxHxD)

Packing (WxHxD)

Net/Gross weight

Refrigerant type

96000

28

2.64

105000

30

2.93

4400/3800/3300

120

55/50/45

1440×811×448

1595×855×560

100/104

R22

DN25

140-187

47

mm

°C

m2

20'/40'/40'HQ

CTHi-96H

220~240/1/50

110000

32

3.1

116000

34

3.11

5400/5100/4750

120

65/60/55

1630×720×1145

1835×850×1185

200/220

R22

DN25

160-213

40

CTHi-110H

220~240/1/50

Indoor Unit

Power supply

Capacity

Cooling

V-Ph-Hz

Btu/h

KW

W/W

m3/h

Pa

dB(A)

mm

mm

Kg

 

mm

m

m2

20'/40'/40'HQ

96000

28

2.64

4400/3800/3300

120

55/50/45

1440×811×448

1595×855×560

100/104

R22

DN25

140-187

47

CTHi-96C

220~240/1/50

110000

32

3.10

5400/5100/4750

120

65/60/55

1630×720×1145

1835×850×1185

200/220

R22

DN25

160-213

40

CTHi-110C

220~240/1/50

Cooling Only

Physical data

Piping data

Indoor air flow (Hi/Med/Lo)

Static Pressure

Indoor noise level(Hi/Med/Lo)

Dimension (WxHxD)

Packing (WxHxD)

Net/Gross weight

Refrigerant type

Liquid side/ Gas side

Drainage pipe

Application area

Stuffing Quantity

Capacity

EER

Rated ESP is 120Pa,flexible air duct installation.

96K&110K Btu/h High ESP Ducted Indoor Unit

1

3

Features:

2

Max.refrigerant pipe length is 50m. Max.difference in height 20m.

4 Standard for wired controllr; optional for wireless controller.

Centrifugal fan, low noise and big airflow.

96k/110k Btu/h Optional

Standard

Page 19: 50Hz Light Commercial · 2019. 3. 18. · 2009 2011 The Chigo Air-cooled (Heat Pump) Chiller is included in the 2009 Energy-saving Product Catalog of National Commerce Domain The

50Hz Light Commercial Air Conditioner 50Hz Light Commercial Air Conditioner

3231

R410A Heating Pump

Outdoor Unit

1 drive 2

C2OU-14HVR1

C2OU-18HVR1

1 drive 3

C3OU-21HVR1

C30U-27HVR1

79

127+77+9

7+129+9

9+1279

127+77+9

7+129+9

9+1212+12

79

127+77+9

7+129+9

9+1212+127+7+77+7+9

7+7+127+9+9

7+9+127+12+12

9+9+99+9+12

9+12+1212+12+12

79

1218

7+77+9

7+127+189+9

9+129+18

12+1212+1818+187+7+77+7+9

7+7+127+7+187+9+9

7+9+127+9+18

7+12+127+12+18

9+9+99+9+129+9+18

9+12+129+12+18

12+12+12

CombinationCSG-7HVR1 CSG-9HVR1 CSG-12HVR1 CSG-18HVR1

Indoor Unit

180° sin wave compressor control, higher efficiency and lower power consumption and noise.

Japanese Electronic ship and new design for E-box, easy to heat elimination.

Mitsubishi Twin rotary compressor

Anti-rust design, making electronic parts longer service life.

Dynamic refrigerant control and fuzzy logic manag-ement, more precise control and more user-friendly design.

High efficient and energy-saving EER&COP reaching European A-class energy label.

00000000000000000000000

DC lnverter Multi Split Unit

5

Features:

1

7

4

3

6

2

Dual split(14k/18k Btu/h) Triple split(21k/27k Btu/h)

Wide operating range: cooling: 10-46℃, heating: - 15-24℃

Page 20: 50Hz Light Commercial · 2019. 3. 18. · 2009 2011 The Chigo Air-cooled (Heat Pump) Chiller is included in the 2009 Energy-saving Product Catalog of National Commerce Domain The

50Hz Light Commercial Air Conditioner 50Hz Light Commercial Air Conditioner

3433

lndoor Unit Specification

Indoor Unit

Power supply V/ph/HzCapacity

Cooling

Heating

Btu/hWA

Btu/hWA

7000400.2

8500400.2

9000400.2

10400400.2

12000400.2

13800400.2

1800060

0.2719800

600.27

CapacityInputRated currentCapacityInputRated current

Physical data

Physical data

Indoor air flow (Hi/Med/Lo) Indoor noise level (Hi/Med/Lo) Net Dimension (WxHxD) Packing Dimension (WxHxD) Net/Gross weight Refrigerant Type

m3/hdB(A)mmmmkg

400/345/29030/28/26

800x287x192865x358x275

9/11R410a

450/390/32733/30/27

800x287x192865x358x275

9/11R410a

Refrigerant pipe(Liquid side/ Gas side)

Drainage water pipe diameter Application area

mmmmm2

DN2513-15

DN2516-20

500/431/36435/32/28

800x287x192865x358x275

9/11R410a

750/600/42043/39/35

900x282x202983x377x300

14/16R410a

DN2521-26

DN2532-40

CSG-07HVR1

220~240/1/50

CSG-09HVR1

220~240/1/50

CSG-12HVR1

220~240/1/50

CSG-18HVR1

220~240/1/50

R410A Heating Pump

Indoor units combination Single Double Single Double Single Double Triple Single Double TriplePower supply

Outdoor Unit

V/ph/Hz

Capacity

Cooling

Heating

Compressor Type Brand

CapacityInput

Rated current

EER

Btu/hWA

Btu/(h*W)W/WBtu/h

WA

Btu/(h*W)W/W

7000~12000600~1040

3.0~5.1

1400012146.0

7000~12000600~1050

3.0~5.1

1800016037.9

7000~12000600~1040

3.0~5.1

7000~18000600~1040

3.0~5.1

14000~240001181~2087

5.8~10.3

27000243412.0

14000~180001213~1584

6.0~7.8

2100018609.2

8500~13800660~10843.3~5.4

1700013436.6

8500~13800660~1090

3.3~5.4

2100016658.2

8500~13800648~10623.2~5.2

17000~208001318~1630

6.5~8.1

25500203110.0

8500~19800657~1542

3.2~7.6

17000~276001325~2182

6.5~10.8

31200251112.4

11.53.38

11.53.38

11.33.31

11.13.25

12.73.71

12.63.70

12.63.68

12.43.64

CapacityInput

Rated current

COP

Physical data

Piping data

Max. input consumption Max. current

Outdoor air flow Outdoor noise level Net dimension (WxHxD) Packing dimension (WxHxD)

Net / Gross weight

Liquid side/ Gas side Max. pipe length Max. height difference Ambient temperature Application area

WA

m3/hdB(A)mmmmkg

g

mmmm

m2

6.35/9.523010

-15~4626~30

6.35/9.523010

-15~4635~43

6.35/9.524510

-15~4639~45

6.35/9.524510

-15~4652~65

RefrigerantType

Charged volume

14106.3

16507.4

C2OU-14HVR1

220~240/1/50

C2OU-18HVR1

220~240/1/50

C3OU-21HVR1

220~240/1/50

C3OU-27HVR1

220~240/1/50

DC inverter twin-rotaryMitsubishi

250057

940x332x608995x415x680

38/41R410a1150

17808.8

227010.2

DC inverter twin-rotaryMitsubishi

250057

940x332x608995x415x680

39/42R410a1450

17808.8

227010.2

227010.2

DC inverter twin-rotaryMitsubishi

288057

940x332x8401030x440x960

62/67R410a1550

194010.0

300013.3

251011.8

DC inverter twin-rotaryMitsubishi

310057

900x332x8401030x440x960

63/68R410a1550

Outdoor unitControllerWireless controller

Wired controller

Wireless 8m transmission

5 Operation modes: Auto, Cooling,Dehumidification, Heating, Fan

Timer ON/OFF setting up to 24Hr

Temperature control range 16-32℃

Three fan speed selection

Sleep mode function

LCD display

5~8 m wire length

5 Operation modes: Auto, Cool, Dehumidification, Heat, Fan

Timer ON/OFF setting up to 24Hr

Temperature control range 16-32℃

Three fan speed selection

ZKX-FE-01 ZKX-FE-02