Principal characteristics DN 15: Qn 1.5 PN16 DN 20: Qn 2.5 PN16 Anti-fraud snap-on head Optional : removable head to allow easy meter repair Counter with screen wiper orientable through 350º on site Protected against magnetic fraud Suitable for remote-reading systems Application Long experience with the 520 meter and the constant efforts devoted to improving it have made it possible to achieve an exceptional degree of quality and reliability. The integration of innovative materials has in particular increased the accuracy and measuring range of this meter. The 520 meter thus greatly exceeds the regulatory metrological performance of a Class C meter. Its efficiency as an invoicing tool makes it ideal equipment for operators. Its new pre-fitted counter for the HRI electronic sensor makes the 520 compatible with all modern remote reading applications. Available Options HRI Sensor Pipe to meter couplings Non-return valve in the pipe Upstream and downstream stop valves 520 Volumetric Meter Anti-fraud dry dial All positions Class C L D 1730 INT • Page 1 / 4 International Enquiries Sensus Metering Systems GmbH Ludwigshafen Industriestrasse 16, 67063 Ludwigshafen Germany T: +49 (0) 621-6904-0 F: +49 (0) 621-6904-1409 Email: [email protected] www.sensus.com UK & Ireland Enquiries Sensus Metering Systems 11 The Quadrangle, Abbey Park, Romsey, Hampshire SO51 9DL UK T: +44 (0) 1794 526100 F: +44 (0) 1794 526101 Email: [email protected] www.sensus.com

Upload: others

Post on 19-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 520 Volumetric Meter · individual manufacturing number may also be engraved on the head. Installation and Maintenance Instructions The 520 meter must be installed at a low point

Principal characteristics

DN 15: Qn 1.5 PN16DN 20: Qn 2.5 PN16

Anti-fraud snap-on head

Optional : removable head to allow easy meter repair

Counter with screen wiper orientable through 350º onsite

Protected against magnetic fraud

Suitable for remote-reading systems

Application

Long experience with the 520 meter and the constant efforts devoted to improvingit have made it possible to achieve an exceptional degree of quality and reliability.

The integration of innovative materials has in particular increased the accuracy andmeasuring range of this meter.

The 520 meter thus greatly exceeds the regulatory metrological performance of aClass C meter. Its efficiency as an invoicing tool makes it ideal equipment foroperators.

Its new pre-fitted counter for the HRI electronic sensor makes the 520 compatiblewith all modern remote reading applications.

Available Options

HRI Sensor

Pipe to meter couplings

Non-return valve in the pipe

Upstream and downstream stop valves

520 Volumetric MeterAnti-fraud dry dialAll positions Class C

L D 1730 INT • Page 1 / 4

International EnquiriesSensus Metering Systems GmbH LudwigshafenIndustriestrasse 16,67063 Ludwigshafen GermanyT: +49 (0) 621-6904-0F: +49 (0) 621-6904-1409Email: [email protected]

www.sensus.com

UK & Ireland EnquiriesSensus Metering Systems11 The Quadrangle, Abbey Park,Romsey, Hampshire SO51 9DL UKT: +44 (0) 1794 526100F: +44 (0) 1794 526101Email: [email protected]

www.sensus.com

Page 2: 520 Volumetric Meter · individual manufacturing number may also be engraved on the head. Installation and Maintenance Instructions The 520 meter must be installed at a low point

520LD 1730 INT • Page 2 / 4

Reliability

The 520 meter is a rotary-piston volumetric meter. Thehigh precision machining of the parts making up themechanism ensures the accuracy of the meter withoutany individual adjustment being necessary.

The movement of the self-lubricating measuringmechanism is transmitted to the counter by a pair ofpermanent magnets through a solid non-magneticstainless steel plate. The latter ensures a perfect sealbetween the body and head of the meter.The magnetic transmission is protected againstexternal magnetic influences.

A filter placed at the bottom of the casing providesexcellent filtration of the water. In Qn 2.5, this is astrainer situated in the inlet pipe, protecting themechanism from solid matter.

The 520 meter can be installed horizontally, verticallyor inclined.

Anti-fraud cover

The meter has a plastic head snapped onto the body ofthe meter. This bears the original verification marks.This part has to be broken in order to dismantle themeter.

Legibility

The 9-roller display guarantees simple andunambiguous reading of the meter index duringreadings and checks.

The dial, which can be oriented in service through350º, with its large white figures on a black backgroundfor m3 and on a red background for submultiples,facilitate reading of the index.

An unbreakable hermetically sealed casing enclosesthe counter. A screen wiper guarantees optimumlegibility of the index under all conditions. A coloureddevice makes it possible to check that the measuringmechanism has not been damaged by high mechanicalpressure. This device also makesit possible to detect exposure to frost.

Typical accuracy curve

Typical pressure drop curve

Cross Section

Flow Rate (m3 per hour)

Err

or (

%)

DN 15

DN 20

1

0.5

0.1

0.05

0.01

0.4 0.6 0.8 1 2 3 4 5 6 7

Page 3: 520 Volumetric Meter · individual manufacturing number may also be engraved on the head. Installation and Maintenance Instructions The 520 meter must be installed at a low point

520LD 1730 INT • Page 3 / 4

Conformity

The 520 conforms to Recommendation No 49 of theInternational Organisation of Legal Metrology, ISO4064 and EC Directive 75/33.

Pattern approval No

The various diameters of the 520 are approved inClass C in accordance with EEC pattern approval forall positions:

- Qn 1.5 (DN 15 mm) No B98.32.50

- Qn 2.5 (DN 20 mm) No B98.32.49

Marking

The body bears two arrows indicating the direction offlow.

The year of manufacture, the individual manufacturingnumber, the manufacturer’s mark, the model name, thenominal flow rate, the metrological class and the EECpattern approval reference are printed on the dial. Theindividual manufacturing number may also be engravedon the head.

Installation and Maintenance Instructions

The 520 meter must be installed at a low point in thepipe, complying with the orientation of the arrowsindicating the direction of water flow.

The pipe must be rinsed before installing the meter inorder to discharge all foreign bodies.

It is recommended that a valve be installed in front ofthe meter to enable it to be installed and removed.When the meter is commissioned, open the valve infront of the meter slowly so as to ensure gradual filling.

This meter does not require any special maintenance.

Technical characteristics

(1) Also available in lengths:- 110 and 114 mm thread 3/4" G injected brass body- 130, 134 and 170 mm thread 3/4" G cast brass body- 165 thread 1" G cast brass body(2) Also available in 165 mm length

Dimensional characteristics

Operating characteristics

Metrological characteristics

Dimensional diagram

Nominal Diameter DN mm 15 20

Nominal flow rate Qn m3/h 1.5 2.5

Maximum flow rate Qmax m3/h 3 5

Minimum flow rate ±5% Qmin l/h 15 25

Transitional flow rate ±2% Qt l/h 22.5 37.5

Nominal Diameter mm 15 20

Start-up flow rate l/h 2 4

Counter Maximum range m3 99999 99999

Smallest graduation litre 0.02 0.02

Cyclic volume cm3 39.7 55.3

Nominal pressure bar 16 16

Nominal Diameter DN mm 15 20

Filter Hole cross-section mm2 0.49 0.64

Total cross-section of flow mm2 540 615

Length L mm 165(1) 190(2)

Width La mm 99 99

Total height H mm 112 118

Height from bottom to

pipe axis h mm 34 35

Pipe thread inch 3/4” 1”

Outside diameter mm 26.44 33.25

Pitch mm 1.814 2.309

Weight (without coupling) kg 1.3 1.5

Dimensions and Weights

Page 4: 520 Volumetric Meter · individual manufacturing number may also be engraved on the head. Installation and Maintenance Instructions The 520 meter must be installed at a low point

520L D 1730 INT • Page 4 / 4

LD

1730

INT

/00

3-08

05•

Sub

ject

toch

ange

with

out

notic

e

Equipping with HRI sensor

The dial of the 520 is equipped as standard with apointer able to activate the HRI sensor.

The HRI provides a reliable data source for remotereading of a conventional meter. It is THE interface forall today's requirements for data interrogation andremote transmission.

The HRi is available in two versions :

1. HRI Pulse Unit

The use of the decilitre pointer for activating the HRIallows a basic resolution of one litre per pulse. Thefinal value of the pulse can be set using the divisor D(e.g. D = 100 means 1 pulse per 100 litres).

The possible D values are (in particular): 1 / 10 / 100 / 1000

2. HRI Data Unit

The design of the HRI Data Unit integrates a datainterface to read the index of the meter as well as theserial or customer number. The D value of the Divisor,the serial/subscriber number and the starting index areprogrammable. This version also allows a pulse signalto be emitted simultaneously (4 wire connection).

The HRI Data Unit can be connected to an M-Busnetwork or read through an inductive device (MiniBus)in accordance with the IEC 870 protocol.

Fitting of the HRI sensor

If the meter is equipped with a plastic register, thefitting is done through the installation of two screwsprotected with sealings provided with the sensor.

If the meter is equipped with a copper/glass register, afitting ring, on which the HRI sensor is screwed, allowsan easy and quick installation.

For additional information about the HRI, please referto the LS8100INT datasheet.