550_831_installguide
TRANSCRIPT
-
7/28/2019 550_831_installguide
1/20
1Part Number 550-831
IT-550 ET1Fixed Cellular Gateway
for GSM 900/1800
Hardware Installation Guide
-
7/28/2019 550_831_installguide
2/20
Part Number 550-8312
-
7/28/2019 550_831_installguide
3/20
3Part Number 550-831
Preface
The product described in this manual conforms to the Radio and
Teleterminals directive 1999/5/EC with requirements covering EMC
directive 89/336/EEC and Low Voltage directive 73/23/EEC, Thecouncil of 3/9/99 on Radio Equipment and Telecommunication Terminal
Equipment and the mutual recognition of their conformity and with the
provisions of Annex III after having performed the required measure-
ments.
The information contained in this document is the proprietary informa-
tion ofFLOSYS. The contents are confidential and any disclosure to
persons other than the officers, employees, agents or subcontractors of
the owner or licensee of this document, without the prior written consent
ofFLOSYS is strictly prohibited.
Further, no portion of this publication may be reproduced, stored in a
retrieval system, or transmitted in any form or by any means, electronicor mechanical, including photocopying and recording, without the prior
written consent ofFLOSYS, the copyright holder.
Second Edition (February 2004)
FLOSYS publishes this manual without making any warranty as to the
content contained herein. FurtherFLOSYS reserves the right to make
modifications, additions and deletions to this manual due to typographi-cal errors, inaccurate information, or improvements to programs and/or
equipment at any time and without notice. Such changes will, neverthe-
less be incorporated into new editions of this manual.
2003-2004 FLOSYS LLC all rights reserved.
Designed and Produced by:
FLOSYS LLC.
7327 SW Barnes Rd. #409
Portland, Oregon 97225USA
Email: [email protected]
http://www.flosys.com
-
7/28/2019 550_831_installguide
4/20
Part Number 550-8314
Contents
Preface ..................................................................................... 3
Contents ................................................................................... 4
Safety Information .................................................................... 5
Package Content ..................................................................... 6
Basic Installation ......................................................................... 7
Troubleshooting .......................................................................... 14
Specifications ........................................................................... 17
Support .................................................................................... 18
-
7/28/2019 550_831_installguide
5/20
5Part Number 550-831
Safety Information
Operation of any radio transmitting equipment including cellular phones
may interfere with the functionality of medical devices. Consult the
manufacturer of the medical devices if you have any questions. Otherelectronic equipment, especially inadequately shielded telecommunica-
tion and audio systems may also be subject to interference. Ensure
adequate distance from such equipment to minimize interference.
Only authorized personnel should install or service the unit described in
this manual. Faulty installation or service may be dangerous and may
invalidate the warranty.
-
7/28/2019 550_831_installguide
6/20
Part Number 550-8316
Package Content
Following items are included in the basic IT-550 ET1 package:
IT-550 ET1 fixed cellular gateway.
Antennas.
Installation Guide.
Connectors:
Power supply: 85 265 Vac / 50-60 Hz.
T1/E1 digital span connector.
Ethernet 10baseT / 100baseT Ethernet port.
Antenna ports [1-8].
-
7/28/2019 550_831_installguide
7/20
7Part Number 550-831
Basic Installation
Physical installation of the IT-550 cellular gateway:
The IT-550 cellular gateway is housed in an aluminum 19" rack mountchassis. Both the front and the back panel are hinged to allow easy
access to the GSM SIM cards on the channel boards inside.
Securely mount the IT-550 unit in a 19" rack as shown in diagram 1.
IT-550
Front View
Side View
Front / Rear Clearance
27 cm min. 80 cm min.
Rear PanelFront Panel
Diagram 1: IT-550 Rack Mounting
Allow sufficient space in the front and back for access to the
channel boards.
The power dissipation of the IT-550 is up to 300 watts, make sure toprovide enough air flow access to avoid overheating of the unit.
Special consideration of air flow is required when stacking several
IT-550 gateways or other equipment in a confined space.
-
7/28/2019 550_831_installguide
8/20
Part Number 550-8318
Antenna Installation:
The IT-550 cellular gateway includes directional yagi antennas which
provide optimized performance for the IT-550 cellular gateway.
Lay out the antenna locations so that the distance between any
2 antennas is not less then 90cm (3ft) as shown in diagram 2.
2 meters min.
90cm.
90cm
.
9
0cm.
PBX
Exterior WallYagi Antennas
Diagram 2: Antenna Placement
Antennas should be kept at least 2m (6ft) apart from any telecom
equipment, cables or cable ducts to avoid interference and noiseproblems.
Make sure the antennas point in direction of the cellular base station.
Mount antennas in vertical direction as shown in diagram 3.
Yagi Antenna
Mounting Base
Diagram 3: Antenna Orientation
-
7/28/2019 550_831_installguide
9/20
9Part Number 550-831
Antenna Installation (cont.):
Use 50 ohm coax cable to connect the antennas to the IT-550
unit. Preferred cabletype is RG-58 for cable length of less then6m (20ft). and RG-213 for a cable length of up to 20m (60ft).
For longer cable runs please contact Flosys technical support.
Mount the coax connectors to the cable. Use a TNC connector at
the antenna end and a BNC connector at the gateway end. Check
for shorts and continuity.
Connect the cables to the antennas.
Connect the cables to the antenna ports on the IT-550 gateway as
shown in diagram 4.
IT-550
Serial No.:
ANTENNAS
Power:115-230VAC 50/60Hz.T1/E1 Ethernet
ANTENNASAntenna Cable
Yagi Antenna
Antenna Ports
Diagram 4: Antenna Connection
-
7/28/2019 550_831_installguide
10/20
Part Number 550-83110
T1 / E1 connection:
The IT-550 GSM gateway has a universal T1 (1.544Mb/s) / E1
(2.048 Mb/s) telco port via an RJ-48 connector with a symmetrical100 / 120 Ohm interface as shown in diagram 5.
IT-550
Serial No.:
ANTENNAS
Power:115-230 VAC 50/60Hz.T1/E1 Ethernet
ANTENNAS
T1/E1 Port
Diagram 5: T1/E1 Port Location
To connect to a VoIP gateway or channels bank use the appropriate
RJ-48 straight or crossover cable.
RJ-48 pinout: 1 = Rx +
2 = Rx
4 = Tx
5 = Tx +
T1 or E1 mode and communication protocols will be selected from
the configuration software.
1
8
-
7/28/2019 550_831_installguide
11/20
11Part Number 550-831
Ethernet connection:
The IT-550 cellular gateway has a 10/100baseT Ethernet
connection to connect it to the configuration and managementconsole.
The connector is a regular Cat-5 modular 8 pin connector as shown
in diagram 7.
IT-550
Serial No.:
ANTENNAS
Power:115-230 VAC 50/60Hz.T1/E1 Ethernet
ANTENNAS
Ethernet Port
Diagram 7: Ethernet Port Location
Connect either to a Ethernet hub/switch with a straight Cat-5 cable
or connect directly to a Ethernet-NIC in the configuration computer
via a Cat-5 crossover cable.
The initial ethernet TCP/IP setup will be done via the installation
software.
-
7/28/2019 550_831_installguide
12/20
Part Number 550-83112
Power connection:
The IT-550 cellular gateway is equipped with a universal AC power
supply.
Mains voltage can be either 110 Vac or 230 Vac 5060 Hz. The
power supply will adjust automatically.
Power consumption is Max. 300 watts. (1.5 3.0 Amp).
Use the included power cord to connect the IT-550 cellular gateway
to a properly fused and grounded AC outlet.
The use of an external UPS (Uninterruptible Power Supply) is highly
recommended to avoid problems with power outages, spikes and
power surges.
The power connector includes the main power switch and the
primary fuse (type 5x20mm 5A / 250V) as shown in diagram 8.
IT-550
Serial No.:
ANTENNAS
Power: 115-230 VAC 50/60Hz.T1/E1 Ethernet
ANTENNAS
On/OffSwitch
Connector
Fuse
Diagram 8: Power Connector
-
7/28/2019 550_831_installguide
13/20
13Part Number 550-831
SIM Card Installation:
The IT-550 cellular gateway is capable of utilizing up to 12 SIM cards
per channel. The SIM cards can be rotated manually or automatically byeither timeand / or remaining credit in the case of prepaid cards.
Open the front panel by unscrewing the 3 screws on the top edge of
the panel. Hinge the panel down.
Insert the SIM cards in the SIM card reader slots as shown in
diagram 9.
SIM 4SIM 1 SIM 2 SIM 3
Sub Board
Main Board
Diagram 9: SIM Card Reader Board
Start at the top left channel board for channel 1 until the bottomright board is channel 16 as shown in diagram 10.
Front ViewChannel 1 Channel 9
Channel 8 Channel 18E1 BoardUI Board
Diagram 10: Front View SIM Orientation
-
7/28/2019 550_831_installguide
14/20
Part Number 550-83114
Open the rear panel and hinge it down. Take care that the wiring
does not get tangled up.
Insert the SIM cards in the SIM card reader slots in the samemanner as used in loading the front SIM card readers.
Start at the top left channel board for channel 17 and continue to
the bottom right board for channel 32 as shown in diagram 11.
Rear ViewChannel 17 Channel 25
Channel 24 Channel 32
Diagram 11: Rear View SIM Orientation
Channel 31 and 32 are spare channels which can be activated from
the Configuration Software.
Close the front and rear panel.
The IT-550 cellular gateway is now ready for operation.
NOTE:When the green LED right of a SIM card slot is lit then the SIM
card is currently selectedand in use removing it may disrupt a current
call in progress.
-
7/28/2019 550_831_installguide
15/20
15Part Number 550-831
Troubleshooting
No function at all:
Check that power switch on the back panel is set to ON.
Check that power cord is plugged in and outlet has power.
Check if both green LEDs located on the power supplies on the
back panel are lit. If not check main fuse if fuse is blown replace
with a new fuse (5A/250V).
Red Alarm on T1/E1 interface:
A Red Alarm indicates total loss of connection on a T1 or E1 span.
Check that the T1 / E1 cable is properly plugged into the T1/E1 port
(white port) on the IT-550 and on the proper connector on the
terminating equipment.
Check if either a straight or a cross-connect cable is necessary for
proper operation with your equipment.
If cross-connect is required use a RJ-48 cross-connect cable.
A regular Ethernet Cat-5 cross-connect cable will NOT work.
Poor GSM receive signal:
Check if only a group of channels or all channels are affected by the
poor receiving signal condition.
If only a group of channels (i.e. Ch:1-4) has poor reception:
Check the respective anenna cabling and connectors.
Make sure connectors are fastened tightly.
Check the antenna cable for proper crimping of the connectors.
Check the direction of the antenna pointing towards the GSM
basestation tower.
If all channels are affected by poor GSM signal reception.
Make sure the antennas point in the direction of the GSM
basestation tower.
Check that the antennas are mounted with their directors in a
vertical position.
-
7/28/2019 550_831_installguide
16/20
Part Number 550-83116
Buzzing noise during calls:
If there is buzzing noise during phone calls very likely this is caused
by interference from the GSM transmitter antennas.
Make sure the antennas are at least 6ft / 2m apart from any telecom
equipment, cables or cable ducts to avoid interference and noise
problems.
Make sure the IT-550 cellular gateway is properly grounded.
-
7/28/2019 550_831_installguide
17/20
17Part Number 550-831
Specifications
GENERAL PARAMETERS:
Size: 482 mm. x 266 mm. x 535 mm.
Rack Units: 6RU.
Weight: approx. 15 kgs (30 lbs.).
Mounting: Desktop or Wall mount.
Operating temp: 0C to +45 C.
Humidity: 0-95% non condensing.
POWER:
Mains Voltage: 85 - 265 Vac.
Mains Frequency: 45 - 65 Hz.
Power Consumption: Max. 300W.
Mains Fuse: 5A / 250 V 5x20 mm.
TELCO INTERFACE:
Type: T1 / E1.
Clock Freq: 1.544 MHz / 2.048 MHz.
Clock source: Internal.
Line Code: B8ZS , HDB3.
Framing: ESF, CRC4.
Line Signaling: CAS, CCS.
CONTROL INTERFACE:
Type: Ethernet 10baseT.
Connector: Modular-8 pin (RJ-45).
Addressing: DHCP or static IP.
Interface: TCP/IP link.
User Interface: Windows GUI.
ANTENNA INTERFACE:
Number of Antennas: 8.
Channel to Antenna Ratio: 4:1.
Connectors: 8 x BNC.
Impedance: 50 Ohm.
LOCAL USER INTERFACE:
Type: LCD backlit.
Screen: Graphic / Text.
Input: 2 Softkeys.
CELLULAR NETWORK INTERFACE:
NETWORK
GSM-900 / EGSM-900 / GSM-1800 (DCS-1800).
BAND
900 / 1800 MHz.
POWER CLASS
GSM-900: Class 4 (33 dbm).
GSM-1800: Class 1 (30 dbm).
FREQUENCY RANGE
GSM-900 Tx: 880 - 915 MHz / Rx: 925-960MHz.
GSM-1800 Tx: 1710-1785 MHz / Rx:1805-
1880MHz.
CHANNEL SPACING
200 kHz.
NUMBER OF CHANNELS
GSM-900: 173 Carriers *8 (TDMA)
Channels 1 to 124 and 975 to 1023.
GSM-1800: 374 Carriers *8 (TDMA)
Channels 512 to 885.
MODULATIONGMSK.
TX PHASE ACCURACY
< 5 RMS Phase error (burst).
DUPLEX SPACING
GSM-900: 45 MHz.
GSM-1800: 95 MHz.
RECEIVER SENSITIVITY
< - 100 dBm.
AUTOMATIC HAND-OVER
Automatic hand-over between GSM 900 and
GSM 1800.
SIM CARD INTERFACE:
Type of SIM cards: All 3 5 volt phase I / II
cards supported.
Number of SIM / Channel: 4 / 8 /12.
Virtual SIM feature: Optional.
SIM selection: By time (48 entries) and/or by
remaining credit.
-
7/28/2019 550_831_installguide
18/20
Part Number 550-83118
Support
Via Web: www.flosys.com
Email: [email protected]
Postal Address:
FLOSYS LLC.
7327 SW Barnes Rd. #409
Portland, Oregon 97225
USA
-
7/28/2019 550_831_installguide
19/20
19Part Number 550-831
-
7/28/2019 550_831_installguide
20/20
Part Number 550-83120
2004 FLOSYS LLC all rights reserved.
7327 SW Barnes Rd. #409
Portland, Oregon 97225
Email: [email protected]: www.flosys.com