5cast resin dry-type transformer

2
Rated primary voltage : 12/24kV, 22kV, 33kV CAPACITY NO-LOAD LOSSES LOAD LOSSES AT 75 °C TOTAL LOSSES AT 75 °C IMPEDANCE AT 75 °C VOLTAGE REGULATION AT FULL LOAD (P.F.=1) (kVA) (Watt) (Watt) (Watt) (%) ½ Load (%) Full Load (%) (%) W L H 315 1200 4100 5300 4.0 99.63 99.56 1.37 56 860 1400 1580 400 1400 4800 6200 4.0 99.63 99.56 1.27 56 860 1500 1600 500 1650 5900 7550 4.0 99.62 99.54 1.25 56 960 1550 1650 630 1960 6900 8860 4.0 99.63 99.55 1.17 57 960 1600 1800 800 2300 8300 10600 6.0 99.62 99.54 1.21 58 1060 1700 1870 1000 2660 9600 12260 6.0 99.62 99.54 1.14 58 1160 1800 1965 1250 3100 11800 14900 6.0 99.61 99.52 1.12 60 1160 1840 2020 1600 3800 14000 17800 6.0 99.62 99.53 1.05 61 1160 1920 2110 2000 5000 17000 22000 6.0 99.63 99.56 1.03 61 1160 1950 2140 2500 5800 20000 25800 7.0 99.63 99.56 1.04 63 1260 2150 2600 1. The transformer is designed to operate under the following conditions Altitude : Up to 1000 m above sea level Ambient air temperature : 40 °C maximum 2. Limits of temperature rise (winding) : 100 °C maximum 3. Insulation class : F 4. Connection symbol : Dyn 11 5. Reference standard : IEC standard 6. Special vector group and other primary voltage available upon request TME-TDDC-1509 TECHNICAL DATA OF DRY TYPE CAST RESIN THREE PHASE TRANSFORMER (IP00) The contents and specifications of this datasheet are subject to change without prior notice. No part of this data may be reproduced without the prior approval of Thai Maxwell Electric. EFFICIENCY (P.F.=1) NOISE LEVEL dB (A) : 0.3 m OUTLINE DIMENSION (APPROX in mm.) Note : TOTAL WEIGHT (APPROX) (kg) 1550 1700 5250 6800 1980 2510 2950 3500 3900 4800

Upload: tdkishorebabu654

Post on 30-Jan-2016

13 views

Category:

Documents


0 download

DESCRIPTION

Resin Dry-type Transformer

TRANSCRIPT

Page 1: 5Cast Resin Dry-type Transformer

Rated primary voltage : 12/24kV, 22kV, 33kV

CAPACITYNO-LOAD

LOSSES

LOAD

LOSSES

AT 75 °C

TOTAL

LOSSES

AT 75 °C

IMPEDANCE

AT 75 °C

VOLTAGE

REGULATION

AT FULL LOAD

(P.F.=1)

(kVA) (Watt) (Watt) (Watt) (%)½ Load

(%)

Full Load

(%)(%) W L H

315 1200 4100 5300 4.0 99.63 99.56 1.37 56 860 1400 1580

400 1400 4800 6200 4.0 99.63 99.56 1.27 56 860 1500 1600

500 1650 5900 7550 4.0 99.62 99.54 1.25 56 960 1550 1650

630 1960 6900 8860 4.0 99.63 99.55 1.17 57 960 1600 1800

800 2300 8300 10600 6.0 99.62 99.54 1.21 58 1060 1700 1870

1000 2660 9600 12260 6.0 99.62 99.54 1.14 58 1160 1800 1965

1250 3100 11800 14900 6.0 99.61 99.52 1.12 60 1160 1840 2020

1600 3800 14000 17800 6.0 99.62 99.53 1.05 61 1160 1920 2110

2000 5000 17000 22000 6.0 99.63 99.56 1.03 61 1160 1950 2140

2500 5800 20000 25800 7.0 99.63 99.56 1.04 63 1260 2150 2600

1. The transformer is designed to operate under the following conditions

Altitude : Up to 1000 m above sea level

Ambient air temperature : 40 °C maximum

2. Limits of temperature rise (winding) : 100 °C maximum

3. Insulation class : F

4. Connection symbol : Dyn 11

5. Reference standard : IEC standard

6. Special vector group and other primary voltage available upon request

TME-TDDC-1509

TECHNICAL DATA OF DRY TYPE CAST RESIN THREE PHASE TRANSFORMER (IP00)

The c

onte

nts

an

d s

pecific

ations o

f th

is d

ata

shee

t are

subje

ct to

chan

ge w

itho

ut p

rior

no

tice. N

o p

art

of

this

da

ta m

ay b

e r

epro

duced w

itho

ut th

e p

rior

ap

pro

val of

Thai M

axw

ell

Ele

ctr

ic.

EFFICIENCY

(P.F.=1) NOISE

LEVEL dB

(A) : 0.3 m

OUTLINE DIMENSION

(APPROX in mm.)

Note :

TOTAL WEIGHT

(APPROX)

(kg)

1550

1700

5250

6800

1980

2510

2950

3500

3900

4800

Page 2: 5Cast Resin Dry-type Transformer

Rated primary voltage : 12/24kV, 22kV, 33kV

CAPACITYNO-LOAD

LOSSES

LOAD

LOSSES

AT 75 °C

TOTAL

LOSSES

AT 75 °C

IMPEDANCE

AT 75 °C

VOLTAGE

REGULATION

AT FULL LOAD

(P.F.=1)

(kVA) (Watt) (Watt) (Watt) (%)½ Load

(%)

Full Load

(%)(%) W L H

315 1200 4100 5300 4.0 99.63 99.56 1.37 56 1360 1850 1880

400 1400 4800 6200 4.0 99.63 99.56 1.27 56 1360 1950 1900

500 1650 5900 7550 4.0 99.62 99.54 1.25 56 1460 2000 1950

630 1960 6900 8860 4.0 99.63 99.55 1.17 57 1460 2050 2100

800 2300 8300 10600 6.0 99.62 99.54 1.21 58 1560 2150 2170

1000 2660 9600 12260 6.0 99.62 99.54 1.14 58 1660 2250 2270

1250 3100 11800 14900 6.0 99.61 99.52 1.12 60 1660 2290 2320

1600 3800 14000 17800 6.0 99.62 99.53 1.05 61 1660 2370 2410

2000 5000 17000 22000 6.0 99.63 99.56 1.03 61 1660 2400 2440

2500 5800 20000 25800 7.0 99.63 99.56 1.04 63 1760 2600 2900

1. The transformer is designed to operate under the following conditions

Altitude : Up to 1000 m above sea level

Ambient air temperature : 40 °C maximum

2. Limits of temperature rise (winding) : 100 °C maximum

3. Insulation class : F

4. Connection symbol : Dyn 11

5. Reference standard : IEC 60726 or IEC 60076-11

6. Special vector group and other primary voltage available upon request

TME-TDDC-1609

TECHNICAL DATA OF DRY TYPE CAST RESIN THREE PHASE TRANSFORMER (IP21)

The c

onte

nts

an

d s

pecific

ations o

f th

is d

ata

shee

t are

subje

ct to

chan

ge w

itho

ut p

rior

no

tice. N

o p

art

of

this

da

ta m

ay b

e r

epro

duced w

itho

ut th

e p

rior

ap

pro

val of

Thai M

axw

ell

Ele

ctr

ic.

EFFICIENCY

(P.F.=1) NOISE

LEVEL dB

(A) : 0.3 m

OUTLINE DIMENSION

(APPROX. in mm.)TOTAL WEIGHT

(kg)

1970

2140

2440

7500

Note :

2990

3450

4050

4450

5380