Page 1: 5Power Cable Specs Set 2 - Condumex  · PDF fileCondumex Wire and Cable 2590 114th Street, ... Type Conductors Diameter Ampacity Weight AWG ... 6 19 26.2 0.18 30 6 0.26

CablesELECTRICALE L E C T R I C A L

July 28 2009

CONDUMEX INCORPORATEDWIRE amp CABLE PRODUCT INDEX

MTWTHHNTHWN 600 VOLTS COPPER 14 AWG SOLID 750 MCM STRANDED UL 83 XHHW-2 600 VOLTS COPPER 14 AWG 1000 MCM STRANDED UL 44 RHH-RHW-USE 600 VOLTS COPPER (XLP) 6 AWG 1000 MCM STRANDED UL 44 MC Cable XHHW or XHHW-2 600 VOLTS ALUMINUM

BUILDING WIRE

TYPE TCTHHN 600 VOLTS COPPER 14 AWG STRANDED 750 MCM STRANDED 3 ANDOR 4 CONDUCTOR WITH OR WITHOUT BARE GROUND WIRE (SIZES 8 AWG AND LARGER) UP TO 16 CONDUCTOR

FOR SIZES 14 12 AND 10 AWG UL 1277 ldquoERrdquo LISTED TYPE TCXHHW-2 600 VOLTS COPPER 14 AWG STRANDED 750 MCM

STRANDED 3 ANDOR 4 CONDUCTOR WITH OR WITHOUT BAREGROUND WIRE (SIZES 8 AWG AND LARGER) UP TO 16 CONDUCTORFOR SIZES 14 12 AND 10 AWG UL 1277 ldquoERrdquo LISTED

TYPE TCXHHW-2 600 VOLTS COPPER 10 TO 14 AWG STRANDEDUP TO 19 CONDUCTOR ON 12 AND 14 AWG AND 12 CONDUCTORS ON 10 AWG UL LISTED FOR ldquoERrdquo AND DIRECT BURIAL

TRAY CABLE

POWER CABLE PRIMARY URD CABLES 15 KV 35 KV 100 amp 133 INSULATION

LEVELS COPPER OR ALUMINUM CONDUCTOR EPR OR TR-XLP INSULATION CONCENTRIC COPPER WIRE NEUTRAL WITH OR WITHOUT ENCAPSULATING JACKET OVERALLSPECIFICATIONS ICEA S-94-649 amp AEIC CS8

TYPE MV-90 amp MV-105 (EPR INSULATION ONLY FOR MV-105) POWER CABLE 5 KV - 35 KV 100 amp 133 INSULATION LEVELS COPPER CONDUCTOR EPR OR XLP INSULATION COPPER DRAIN WIRE OR COPPER TAPE METALLIC SHIELD BLACK PVC SUNLIGHT RESISTANT JACKET SINGLE CONDUCTOR CONSTRUCTIONLISTED UL 1072 SPECIFICATIONS ICEA S-93-639 amp AEIC CS8

TYPE MC ARMORED CABLES 600 VOLTS 5 KV - 15 KV MULTI-CONDUCTOR STRANDED COPPER EPR OR XLP INSULATION ALUMINUM OR GALVANIZED STEEL INTERLOCKED ARMOR PVC SUNLIGHT RESISTANT JACKET OVERALL UL 1569

HIGH VOLTAGE POWER CABLES UP TO 138 KV COPPER OR ALUMINUM CONDUCTOR XLP UNSULATION METALLIC SHIELDPVC JACKETSPECIFICATION AEIC Cs7

BARE OVERHEAD CONDUCTORS TYPES AAC AND ACSR PER ASTM B230 amp B232 VULCANEL EPR ANTILLAMA CABLE 600 VOLT NETWORK CABLE

SPECIAL PURPOSE CABLES

TYPE RHH-RHW 2000 VOLTS (DLO) SINGLE CONDUCTOR TINNED COPPER ROPE-LAY STRANDED EPR INSULATION SEPARATOR BLACK CSPE JACKET CONDUCTOR SIZES 4 AWG 1 AWG UL LISTED AS VW-1 SIZES 10 AWG 9292 MCM UL LISTED FOR ldquoCT USErdquo CSA LISTED AS FT4 SIZE 1111 MCM IS PER ICEA S-95-658

Condumex Wire and Cable th 2590 114 Street - Grand Prairie TX 75050 - (800) 925-947311-05

Notes

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947304-11

HOW TO ORDER

MC Armalat Vinilat Nylon Cable TypeTHHNTHWN gauge and length

DESCRIPTION

identification Types THHN-THWN

1) Soft annealed wire or stranded class C

copper conductor

2) PVC insulationNylon jacket with color

APPLICATION

Dry Locations (THHN Type) 90deg C

High resistance to heat and moisture

Good resistance to gasoline and oil

UL-1569

Flame retardance

SPECIFICATIONS

impact and abrasion3)The armor makes the cable resistant to

4) Type THHNTHWN offers

2) Aluminum interlock armor provides greatinstallations

Metal Clad Cable

Wet Locations (THWN Type) 75deg C

Flexibility

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

MAXIMUM OPERATING VOLTAGE

1) Easy installation on exposed or concealed

FEATURES

14 Solid 2 0242rdquo 0414rdquo 25 97

14 Solid 3 0269rdquo 0442rdquo 25 117

14 Solid 4 0302rdquo 0475rdquo 25 137

12 Solid 2 0277rdquo 0450rdquo 30 126

12 Solid 3 0309rdquo 0482rdquo 30 154

12 Solid 4 0347rdquo 0520rdquo 30 183

10 Solid 2 0346rdquo 0519rdquo 40 178

10 Solid 3 0386rdquo 0559rdquo 40 221

10 Solid 4 0434rdquo 0606rdquo 40 266

8 Stranded 2 0492rdquo 0664rdquo 55 259

8 Stranded 3 0549rdquo 0721rdquo 55 332

8 Stranded 4 0617rdquo 0789rdquo 55 406

6 Stranded 2 0568rdquo 0741rdquo 75 361

6 Stranded 3 0634rdquo 0807rdquo 75 468

6 Stranded 4 0713rdquo 0885rdquo 75 577

Dimension and weights shown are nominal unless otherwise indicated and subject to

Size Number of Nominal Nominal Allowable NetType Conductors Diameter Diameter Ampacity Weight

AWGUnder Armor Over ArmorAWG 90 C lbMft

manufacturing tolerances

11

3) Insulated grounded conductor

4) Plastic binder tape

5) Interlocked aluminum armor

Branch feeder and service power distributionsin industrial commercial and residential buildings For power lighting control and signal circuits in generalApplications where maximum security is required as hazardous locations Class I Div 2 Class II Div 2 and Class III Div I

UL-1581

File E 115900

TM TM

TYPE MC Metal Clad Cables

THHNTHWN 600V ArmalatTM

5) Insulated ground (green) is same construction as conductors

2 Conductor black white

3 Conductor black white red

4) Conductor color code

4 Conductor black white red blue

Type MC Cable meets or excides all applicable ASTM Specifications UL standards for safety

UL-83

Armored Cable

11

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947311-10

THHN or THWN-2 600 VOLTS (MTW STRANDED)

DESCRIPTION

2) Polyvinyl chloride (PVC insulation)3) Nylon overall protective jacket

123

Dimension and weights shown are nominal unless otherwise indicated and subject to

14 1 Solid 41 006 15 5 010

12 1 Solid 65 008 15 5 012

10 1 Solid 103 010 20 5 015

14 19 41 007 15 5 012

12 19 65 009 15 5 014

10 19 103 011 20 5 017

8 19 165 015 30 5 023

6 19 262 018 30 6 026

4 19 417 023 40 6 034

3 19 526 026 40 7 036

2 19 663 029 40 7 039

1 19 837 032 50 7 045

10 19 106 037 50 8 050

20 19 133 041 50 8 054

30 19 168 047 50 8 059

40 19 211 052 50 8 065

250 37 057 60 9 072

300 37 062 60 9 078

350 37 067 60 9 083

400 37 072 60 9 087

500 37 080 60 9 096

600 61 088 70 10 106

750 61 098 70 10 115

1000 61 114 70 10 127

16

23

37

17

26

40

65

99

157

197

241

306

380

472

587

729

870

1033

1196

1359

1685

2023

2454

3347

Size Number Conductor Conductor Insulation Jacket OverallAWG of Area Diameter Thickness Thickness Diameterkcmil Strands kcmil mils mils mils inch

NetWeightlbmft

manufacturing tolerances

VINILAT Nylon solid or stranded typereg

General use in commercial and industrial

SPECIFICATIONS

construction and installations whereresistance against oils and gasoline is

APPLICATION

75deg CIn oil (Oil resistant II)

6) Superior abrasion and mechanical properties7) Sizes 10 and larger are marked For CT use and are approved for installation

overload exists

in cable trays Sunlight resistant in Accordance with NEC Article 318

manufacturing process4) Flame retardant UL listed as VW-15) Smooth nylon jacket aids in easier pulling

1) Good resistance to moisture heat oil gasoline chemicals and grease2) Suitable for installation where thermal

3) Strict quality control during

FEATURES

MAXIMUM CONDUCTOR TEMPERATURE

Dry locations (THHN)Dry and wet locations (THWN-2)

90deg C90deg C

MAXIMUM OPERATING VOLTAGE

600 volts

required May be used for power and

gases gasoline and chemicals Alsosuitable as machine tool and switchboard

control circuits in recognized raceways inwet or dry locations and in presence of

wiring

UL-83

HOW TO ORDER

NATIONAL ELECTRICAL CODE REFERENCE

Ampacities

Switchboard wiring

Conduit fill tables

Article 3 10-15

Article 384

Chapter 9

THHN or THWN-2 600 volts size color and length

12

RoHS

IEEE 1202 and ULFT4 Flame Test

CESMEC E-022-01-5505

Type THHN or THWN-2 Annealed bare solid (14-10 AWG) type THHN or THWN-2 Annealed bare stranded class C concentric round (14-2 AWG) compressed stranding class B (1 AWG-1000MCM)copper conductor

1)

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947311-10

XHHW-2 600 VOLTS

POWER CABLE TYPE TC

DESCRIPTION

Dimension and weights shown are nominal unless otherwise indicated and subject to

Size Number Number Jacket Overall Netof of Thickness Diameter WeightAWG

Strands Conductors mils inches lbMft

2 45 033 65

3 45 035 81

4 45 038 103

14 7 5 45 042 125

7 60 049 182

9 60 060 230

12 60 067 288

19 80 077 455

2 45 041 84

3 45 043 112

4 45 047 140

5 45 051 172

12 7 7 60 063 247

9 60 073 310

12 60 081 397

19 80 098 626

2 45 046 97

3 45 048 125

4 60 057 173

10 7 5 60 062 209

7 60 071 279

9 60 081 350

12 80 095 481

manufacturing tolerances

FEATURES

Wet or DryDry

90deg C90deg C

APPLICATION

Electrical Code

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet ordry locations and in the presence of oil and most

lighting control signal and communcation circuitsin raceways direct burial in earth or in

SPECIFICATIONS

S-73-532 (table E-2 or Method SB 4)7) Circuit identification color coded per ICEA

UL 1277 UL 44

HOW TO ORDER

chemicals in accordance with the National

MAXIMUM OPERATING VOLTAGE

600 volts

MAXIMUM CONDUCTOR TEMPERATURE

Condumex Tray Cable Type TCXHHW-2

600 volts number and size of conductors

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

BTU flame test3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

Electrical Code

tray cable used in accordance with the National

Resistant I

O5) PVC jacket is UL rated 90 C and listed Oil

Location Applications6) Acceptable for Class I Division 2 Hazardous

7a) Other color coding methods are available based on ICEA S-73-532

24 13

1) Annealed bare Class C concentric strand copper conductors2) Flame retardant XLPE3) Binder tape over core4) Overall flame retardant PVC jacket

Contact factory for items not shown above

8) ldquoERrdquo Listed per UL 1277

1113

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947311-10

THHNTHWN 600 VOLTS

POWER CABLE TYPE TC

DESCRIPTION

2) Polyvinyl Chloride (PVC) thermoplastic

insulation

1) Annealed bare Class C concentric

strand copper conductors

3) Nylon protective covering

4) Binder tape over core

5) Overall flame retardant PVC jacket

Dimension and weights shown are nominal unless otherwise indicated and subject to

Size Number Number Jacket Overall Netof of Thickness Diameter WeightAWG

Strands Conductors mils inches lbMft

2 45 034 68

3 45 036 87

4 45 040 109

14 19 5 45 043 130

7 45 046 167

9 60 056 234

12 60 063 285

16 60 067 335

2 45 038 90

3 45 040 119

4 45 043 154

5 45 046 173

12 19 7 60 055 247

9 60 064 326

12 60 071 400

16 60 076 485

2 45 045 139

3 45 047 180

4 60 055 247

10 19 5 60 060 178

7 60 065 367

9 60 075 480

12 80 089 637

manufacturing tolerances

FEATURES

Wet or DryDry

75deg C90deg C

APPLICATION

Electrical Code

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet ordry locations and in the presence of oil and most

lighting control signal and communcation circuitsin raceways direct burial in earth or in

SPECIFICATIONS

S-73-532 (table E-2 or Method SB 4)7) Circuit identification color coded per ICEA

UL 1277 UL 83 and ER Approved

HOW TO ORDER

chemicals in accordance with the National

MAXIMUM OPERATING VOLTAGE

600 volts

MAXIMUM CONDUCTOR TEMPERATURE

Condumex Tray Cable Type TCTHHN

600 volts number and size of conductors

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

BTU flame test3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

Electrical Code

tray cable used in accordance with the National

Resistant I

O5) PVC jacket is UL rated 90 C and listed Oil

required metallic sheathed cablessubstantial cost savings over the previouslyLocation Applications Type TX offers

6) Acceptable for Class I Division 2 Hazardous

7a) Other color coding methods are available based on ICEA S-73-532

4

245 13

8) ldquoERrdquo Listed per UL 1277

RoHS

5) Binder tape over core

750 kcmil) copper conductors

6) Overall flame retardant PVC jacket

DESCRIPTION

3) Nylon protective covering4) Fillers

1) Annealed bare Class C (8-2 AWG)compressed stranded Class B (10 AWG-

2) Polyvinyl Chloride thermoplastic insulation

36 145 2

POWER CABLE TYPE TC

THHNTHWN 600 VOLTS

Size Number Ground Insulation Jacket Overall Netof Conductor Thickness Thickness Diameter Weight

AWGkcmilConductors AWG mils mils inch lbMft

8 3 10 305 60 0638 338

6 3 8 305 60 0698 448

4 3 6 407 80 0884 693

2 3 6 407 80 1015 1012

1 3 8 507 80 1150 1210

10 3 6 508 80 1223 1495

20 3 6 508 80 1320 1858

30 3 4 508 80 1428 2297

40 3 4 508 80 1549 2791

250 3 4 609 80 1760 3374

350 3 3 609 110 1980 4526

500 3 2 609 110 2260 6230

750 3 1 7010 110 2967 8845

10 4 6 508 80 1350 1913

20 4 6 508 80 1457 2311

40 4 4 508 110 1773 3597

350 4 3 609 110 2188 5754

500 4 2 609 110 2502 8018

750 4 1 7010 140 3057 11716

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

MAXIMUM OPERATING VOLTAGE

UL 1277 UL 83 and ER Approved

7) Circuit identification color coded per ICEA

MAXIMUM CONDUCTOR TEMPERATURE

Wet or DryDry

75deg C90deg C

required metallic sheathed cables

3) Sunlight resistant can be installed outdoors

tray cable use in accordance with the National

Electrical Code

APPLICATION

in accordance with the National Electrical Code

6) Acceptable for Class I Division 2 Hazardous

4) UL listed as Type TC for power and control

600 volts

5) PVC jacket is UL rated 90deg C and listed Oil

Resistant I

1) UL listed for direct burial

2) Flame retardant (passes UL 1277 70000

BTU flame test)

FEATURES

Condumex Type TC cable may be used for

cable may be used in wet or dry locations and in the presence of oil and most chemicals

power lighting control signal and communication circuits in raceways direct

HOW TO ORDER

600 volts number and size of conductorsCondumex Tray Cable Type TCTHHN

SPECIFICATIONS

S-73-532 (table E-2 or Method SB 4)

Location Applications Type TC offers

substantial cost savings over the previously

7a) Other color coding methods are available based on ICEA S-73-532

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947303-06

5

8) ldquoERrdquo Listed per UL 1277

RoHS

1) Annealed bare stranded class B compact

copper conductor

DESCRIPTION

3) Ethylene propylene (EPR) or cross-linked

polyethylene (XLPE) insulation

4) Polyvinyl chloride (PVC) protective jacket

2) Extruded semiconducting strand shield

VULCANELreg MEDIUM VOLTAGE

WET OR DRY POWER CABLE 5 KVXLPE OR EPR NON-SHIELDED

24 13

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

Size Number Conductor Insulation Insulation Jacket OverallAWG of Diameter Thickness Diameter Thickness Diameterkcmil Strands inch inch inch mils Inch XLPE EPR

Net WeightLbMft

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

manufacturing tolerances

5kV 133 Insulation Level 115 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject to

cable voltage and insulation level conductor

Ampacities

Cable Trays

Type MV

ICEA S-66-524 AEIC CS-S (XLP)

extrusion) results in a virtually perfect cable core

- Very low dielectric loss

Normal Operation 105deg C130deg CEmergency Overload

VULCANELreg 5kv Non-shielded power cables

adequate for proper termination of the shielding

1) Simultaneous extrusion of strand shield

250deg CShort Circuit

UL 1072

326

318

310-15

National Electrical Code References

VULCANELreg EPRXLPE Non-Shielded power

size and type length and reel dimensions

SPECIFICATIONS

are ideally suited for use in industrial andutility applications where shields cannot be

APPLICATION

abrasion ozone and moisture

- Electrical stability under stress- Low dielectric loss- Chemical resistance

FEATURES

3) Easy-stripping insulation shield4) The external PVC jacket is resistant to

EPR insulation offers- Excellent heat moisture and corona

2) XLPE insulation offers- Low moisture absorption- Good resistance to chemicals

insulation and insulation shield (triple

accordance with the National ElectricalCode

5) UL listed as MV-105 sunlight resistantdirect burial Optional marking For CTuse available on single conductor in

HOW TO ORDER

resistance

MAXIMUM CONDUCTOR TEMPERATURE

Page 1 of 2

ICEA S-68-516 AEIC CS-6-87 (EPR)

6

RoHS

VULCANELreg MEDIUM VOLTAGE

WET OR DRY POWER CABLE 5 KVXLPE OR EPR NON-SHIELDED

Page 2 of 2

Size Number Conductor Insulation Insulation Jacket OverallAWG of Diameter Thickness Diameter Thickness Diameterkcmil Strands inch inch inch mils Inch XLPE EPR

Net WeightlbMft

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

25kV 100 Insulation Level 260 mils Insulation Thickness

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

35kV 100 Insulation Level 345 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

15kV 133 Insulation Level 220 mils Insulation Thickness

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

17

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANELreg MEDIUM VOLTAGE EPR

SHIELDED POWER CABLES 5 15 25 35 KV

346 125

DESCRIPTION

1) Annealed bare stranded class B compactcopper conductor

2) Extruded semiconducting strand shield3) Ethylene propylene rubber (EPR) insulation4) Extruded semiconducting insulation shield5) Annealed copper tape shield (25 overlap

6) Polyvinyl chloride (PVC) protective jacketminimum)

Three-phase electrical distribution systems

trays

Suitable for use in overhead installationsrecognized raceways direct burial or cable

APPLICATION

voltage and insulation level conductor

AmpacitiesCable TraysType MV

- Chemical resistance

5) The external PVC jacket is resistant to

- Electrical stability under stress

MAXIMUM CONDUCTOR TEMPERATURE

SPECIFICATIONS

use available on single conductor in

accordance with the National ElectricalCode

abrasion ozone and moisture6) UL listed as MV-105 sunlight resistant

direct burial Optional marking For CT

3) Easy-stripping insulation shield4) Tape shield provides high short circuit

capabilities and uniform shield impedance

- Low dielectric loss

UL 1072

size and type length and reel dimensions

ICEA S-68-516 AEIC CS6-87

326318310-15

National Electrical Code References

VULCANELreg EPR shielded power cable

2) EPR insulation offers- Excellent heat moisture and corona

resistance

insulation and insulation shield (tripleextrusion) results in a virtually perfect

cable core

250 degCShort Circuit

1) Simultaneous extrusion of strand shield

Normal Operation 105 degC130 degCEmergency Overload

FEATURES

SPECIFICATIONS

HOW TO ORDER

Page 1 of 2

Size Number Conductor Insulation Insul Shld Jacket Overall Netof Diameter Thickness Diameter Thickness Diameter Weight

AWGkcmilStrands Inch inch inch mils Inch lbMft

6 7 017 045 053 60 067 290

4 7 022 049 057 60 071 357

2 7 027 055 063 60 074 478

10 19 034 062 070 80 085 668

20 19 038 066 074 80 092 775

30 19 043 071 079 80 097 933

40 19 048 076 084 80 102 1071

250 37 052 081 090 80 107 1226

350 37 062 091 099 80 117 1560

500 37 074 103 113 80 132 2150

750 61 091 121 132 80 150 3027

1000 61 111 136 146 80 164 3845

5kV 133 Insulation Level 115 mils Insulation Thickness

2 7 027 067 075 80 093 570

10 19 034 074 082 80 100 736

20 19 038 078 086 80 104 849

30 19 043 083 091 80 109 1010

40 19 048 088 096 80 114 1190

250 37 052 094 102 80 120 1330

350 37 062 103 114 80 132 1753

500 37 074 116 126 80 144 2280

750 61 091 134 144 80 162 3142

1000 61 111 136 159 110 183 5794

5kV 100 Insulation Level 175 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

Page 2 of 2

VULCANELreg MEDIUM VOLTAGE EPR

SHIELDED POWER CABLES 5 15 25 35 KV

Size Number Conductor Insulation Insul Shld Jacket Overall Netof Diameter Thickness Diameter Thickness Diameter Weight

AWGkcmilStrands Inch inch inch mils Inch lbMft

6 7 017 045 053 60 067 290

4 7 022 049 057 60 071 357

2 7 027 055 063 60 074 478

10 19 034 062 070 80 085 668

20 19 038 066 074 80 092 775

30 19 043 071 079 80 097 933

40 19 048 076 084 80 102 1071

250 37 052 081 090 80 107 1226

350 37 062 091 099 80 117 1560

500 37 074 103 113 80 132 2150

750 61 091 121 132 80 150 3027

1000 61 111 136 146 80 164 3845

15kV 133 Insulation Level 220 mils Insulation Thickness

10 19 034 092 100 80 118 894

20 19 038 096 104 80 122 1009

30 19 043 100 111 80 129 1181

40 19 048 106 116 80 134 1394

250 37 052 111 122 80 140 1537

350 37 062 121 131 80 149 1936

500 37 074 133 143 80 161 2516

750 61 091 151 161 110 185 3620

1000 61 111 166 180 110 204 4543

25kV 100 Insulation Level 260 mils Insulation Thickness

10 19 034 109 119 80 137 1041

20 19 038 113 123 80 141 1226

30 19 043 118 128 80 146 1380

40 19 048 123 133 80 151 1569

250 37 052 129 139 80 157 1750

350 37 062 138 149 80 167 2163

500 37 074 150 161 110 185 2893

750 61 091 168 183 110 207 3900

1000 61 111 183 197 110 221 4807

35kV 100 Insulation Level 345 mils Insulation Thickness

manufacturing tolerancesDimension and weights shown are nominal unless otherwise indicated and subject to

19

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-94735-05

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

ICEA-S-68-516

SPECIFICATIONS

three conductor cable voltage size andlength

Condumex Mining Cable EPR type SHD-GC

HOW TO ORDER

MINING CABLE EPR TYPE SHD-GC

THREE CONDUCTOR 5000 VOLTS

18SHD-GC01

with a nylon webbing provides a tough defense

round configuration

and Health Administration Approval No P-218-1-MSHA

by the Pennsylvania Department of Environmental

Resources Meets MSHA flame test requirements

6) Acceptance No P-218-1-MSHA by Mines Safety

5) CV-Cured extra-heavy-duty CPE reinforced

4) Prevulcanized thermosetting non-wicking fillers

mechanical resistant jacket

resistance outstanding corona resistance

high dielectric strength and chemical resistance

designed for flexibility and resistance to

FEATURES

2) Ground check conductor facilitates fail-safe

3) EPR insulation offers excellent heat and moisture

are used if necessary to obtain a substantially

1) Special tinned copper stranded conductors

fatigue resulting from bending and flexing

ground monitoring for maximum safety

Dimension and weights shown are nominal unless otherwise indicated and subject to

6 7x3029 020 110 10 8 156

4 7x4729 025 110 8 8 168

2 7x7429 031 110 6 8 187

1 7x3725 035 110 5 8 195

10 7x4725 039 110 4 8 208

20 7x6025 045 110 3 8 220

30 7x7525 050 110 2 8 236

40 19x3525 059 110 1 8 250

300 19x4925 069 120 10 8 281

350 19x5825 076 120 20 8 295

1675

1888

2322

2653

3068

3504

4206

5023

6371

7654

Size Number of Conductor Insulation Ground Ground OverallAWG Strands Diameter Thickness Size Check Size Diameterkcmil AWG inch mils AWG AWG inch

NetWeightlbmft

manufacturing tolerances

MAXIMUM CONDUCTOR TEMPERATURE

Normal continuous 90deg C130deg COverload

250deg CShort circuit

MAXIMUM OPERATING VOLTAGE

5000 volts

Trailing cable on ac mining equipment

where service conditions are severe andmaximum safety is mandatory such as

APPLICATION

power shovels and draglines in open-pit

mines quarries gantry cranes and slag

reclaiming Also used for medium voltage

distribution in underground mines where

frequent relocation is necessary

DESCRIPTION

1) Three flexible annealed tinned copper rope-lay stranded conductors

2) Extruded semi-conducting conductor shieldand ethylene propylene rubber (EPR) insulation

3) Color coded cottoncopper braid shield applied over semi-conducting tape

4) Two annealed tinned copper rope-lay strandedgrounding conductors

5) Annealed tinned copper rope-lay stranded

and covered with a yellow cotton braid

chlorinated polyethylene (CPE) jacket

6) Rubberized cotton binder tape7) Nylon web reinforced extra-heavy-duty

ground check conductor yellow EPR insulation

346 2 157

110

RoHS

5) Overall flame retardant PVC jacket

DESCRIPTION

XLP insulation3) Fillers (if required)

4) Binder tape over core

2) Cross-Linked polyethylene thermosetting

1) Annealed bare stranded compressed

Class B copper conductors

without grounding conductorVolts number and size of conductors with or

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet

lighting control signal and communication circuitsin cable trays raceways direct burial or on

HOW TO ORDER

Condumex Tray Cable Type TCXHHW 600

SPECIFICATIONS

UL-1277 amp UL-44

APPLICATION

most chemicals in accordance with the

MAXIMUM OPERATING VOLTAGE

National Electrical Code

or dry locations and in the presence of oil and

6) Acceptable for Class 1 Division 2 HazardousLocations applications

O5) PVC jacket is UL rated 90 C and listed OilResistant I

600 volts

MAXIMUM CONDUCTOR TEMPERATUREO 90 C

O130 C

FEATURES

OverloadNormal

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

National Electrical Code

BTU flame test)3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

tray cable use in accordance with the

3 145 2

POWER CABLE TYPE TC

XHHW 600 VOLTS

Size Number Ground Insulation Jacket Overall Netof Conductor Thickness Thickness Diameter Weight

AWGkcmilConductors AWG mils mils inch lbMft

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 3 10 45 60 066 310

6 3 8 45 60 074 448

4 3 8 45 80 088 659

2 3 6 45 80 103 968

10 3 6 55 80 121 1428

20 3 4 55 80 131 1735

30 3 4 55 80 142 2150

40 3 4 55 80 154 3620

250 3 4 65 110 175 3190

350 3 3 65 110 196 4305

500 3 2 65 110 225 5940

8 4 10 45 60 073 385

6 4 8 45 80 083 568

4 4 8 45 80 097 832

2 4 6 45 80 112 1230

10 4 6 5 80 134 1825

20 4 4 55 80 145 2212

30 4 4 55 80 157 2751

40 4 4 55 110 177 3462

250 4 4 65 110 198 4097

350 4 3 65 110 217 5542

500 4 2 65 110 249 7690

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

111

7) ldquoERrdquo Listed per UL 1277

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

National Electrical Code References

Product Article 310 Table 310-13

Ampacities Article 310-15

HOW TO ORDER

CONDUMEX type RHH-RHW-USE-2

XLPE 600 volts size length quantity

packaging

DESCRIPTION

polyethylene (XLPE) insualtion

1) Annealed bare stranded class B

conductor

2) Flame-retardant cross-linked

TYPE RHH-RHW-USE-2

COPPER XLPE 600 VOLTS

APPLICATION

May be installed in free air all raceways or

underground service entrance cable

Type RHH 90deg C Dry and

temperatures

6) Stable electrical propoerties

UL-44 Standard for Rubber-Insulated

use in direct burial in industrial andcommercial application May be used as

7) Extremely tough

SPECIFICATIONS

4) Good resistance to most oils and

3) UL approved as VW-1 (RHH or RHW)

chemicals5) Suitable for installation in sub-zero

2) UL listed as types RHH or RHW or USE forresistant insulation

damp locations

ICEA S-66-524 Standard for Cross-Linked

Type RHW or 75deg C Dry and

use in accordance with the National

Electrical Code

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

MAXIMUM OPERATING VOLTAGE

USE wet locatinons

1) Flame retardant moisture and heat

FEATURES

Wires and Cables

Polyethylene Insualted Wire and Cable

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch mils inch lbMft

8 7 165 015 60 027 73

6 7 262 018 60 031 108

4 7 417 022 60 035 161

2 7 663 028 60 041 245

10 19 106 036 80 053 392

20 19 133 041 80 058 485

30 19 168 046 80 063 600

40 19 211 051 80 069 746

250 37 056 95 076 887

300 37 061 95 082 1052

350 37 066 95 087 1216

400 37 071 95 092 1380

500 37 079 95 099 1708

600 61 087 110 111 2055

750 61 097 110 120 2542

1000 61 112 110 136 3353

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

11 112

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

copper conductor

2) Cross-linked polyethylene (XLPE)

insulation

compressed (6 AWG-1000 MCM)

1) Annealed bare stranded class B

concentric round (14-8 AWG)

APPLICATION

Power or control circuits in recognized

switchboard wiring

Dry locations 90deg C

presence of oil Also suitable as

designs

temperatures

4) Suitable for installation in sub-zero

pulling and greater conduit fill

5) Optical For CT use marking for use in

cable trays Sunlight resistant in

FEATURES

2) Good moisture resistance

raceways in wet or dry location and in

90deg CWet locationsOverload 130deg CShort Circuit

MAXIMUM OPERATING VOLTAGE

3) Good resistance to most oils and

chemicals

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

accordance with NEC Article 3186) Available in VW-1 and non VW-1

UL-44

SPECIFICATIONS

Chapter 9

250deg C

1) Smaller overall diameter for easier

HOW TO ORDER

National Electrical Code References

Article 310

VULCANELreg XLPE cable type XHHW-2600 volts size and length

Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL

TYPE XHHW-2 600 VOLTS

reg XLPE CABLE

2 1

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch Mils inch lbMft

manufacturing tolerances

14 7 41 007 30 013 19

12 7 65 009 30 015 48

10 7 103 011 30 017 42

8 7 165 015 45 024 71

6 7 262 018 45 027 98

4 7 417 023 45 032 153

2 7 663 029 45 038 241

10 19 1060 037 55 048 378

20 19 1330 041 55 052 446

30 19 1680 047 55 058 556

40 19 2110 052 55 063 697

250 37 057 65 070 851

300 37 062 65 075 997

350 37 067 65 080 1180

400 37 072 65 085 1306

500 37 080 65 093 1662

600 61 088 80 104 1974

750 61 098 80 115 2450

1000 61 114 80 130 3240

Dimension and weights shown are nominal unless otherwise indicated and subject to

13

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

APPLICATION

FEATURES

MAXIMUM OPERATING VOLTAGE

MAXIMUM CONDUCTOR TEMPERATURE

UL-44

SPECIFICATIONS

Chapter 9

HOW TO ORDER

National Electrical Code References

Article 310Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL S8000

XHHW or XHHW-2 600 VOLTS ALUMINUM

reg XLPE CABLE

manufacturing tolerances

Size Number Insulations Overall Netof Thickness Diameter Weight

AWGkcmilStrands Mils In LbMft

6 7 45 027 42

4 7 45 031 59

2 7 45 036 88

1 7 55 042 111

10 19 55 045 136

20 19 55 049 165

30 19 55 054 203

40 19 55 059 250

250 37 65 066 300

300 37 65 071 354

350 37 65 075 405

500 37 65 087 562

600 61 80 098 684

750 61 80 108 840

900 61 80 117 995

Dimension and weights shown are nominal unless otherwise indicated and subject to

2 13

1) Stranded compact class B AA-8000 series aluminum alloy soft conductor2) Separator tape3) Cross-linked polyethylene (XLPE) insulation type XHHW or XHHW-2

Branch-circuits and feeders conductors in low voltage for buildings schools auditoriums hospitals stadiums museums poultry farms etc Industrial and commercial buildings For use in cable trays or raceways in wet and dry locations

600 volts

Wet and dry continuousOverloadShort circuit

90 C130 C125 C

1) Easier pulling and greater conduit fill2) Good moisture resistance3) Excellent dielectrics properties4) Continuous 90 C operating temperature in wet or dry locations5) Suitable for use in cable trays (10 AWG and greater)6) VW-1 compliant7) Sunlight resistant insulatedRoHS compliant

APPROVALS

Type XHHW or XHHW-2 UL listedType Rw90 or RWU90 upon special request

Vulcanel S8000 cable type XHHW or XHHW-2 RoHS CT-SR with stranded compact class B AA-8000 series aluminum alloy soft conductor size length and product number

reg

114

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANEL EPR ANTILLAMA CABLE

600 VOLTS

26ACSR01

DESCRIPTION

FEATURES

HOW TO ORDER

SPECIFICATIONSSPECIFICATIONS

3 2 1

1) Annealed coated or un-coated stranded class B copper conductor2) Ethylene propylene rubber (EPR) insulation3) Chlorosulfonated polyethylene (Hypalon) or chlorinated polyethylene(CPE) jacket

APPLICATION

Ideally suited for use in Electrical generating stations May be installed in free air all raceways or direct burial

MAXIMUM CONDUCTOR TEMPERATUREDry LocationsDry and Wet LocationsOverloadShort Circuit

90 C75 C130 C250 C

MAXIMUM OPERATING VOLTAGE600 Volts

1) Flame resistant Meets or exceeds requirements of IEEE 383 flame test2) Deformation resistant at high temperatures3) Excellent Flexibility at low temperature suitable for installation in sub-zero temperatures4) Extra tough mechanically rugged composite insulation and jacket construction6) Resistant to most oils and chemicals

ICEA S-95-658

VULCANEL EPR ANTILLAMA cable 600 volts size length National Electrical Code ReferencesAmpacities Article 31318-10Cable Trays Article 318

Dupont trade mark

reg reg

Size Number Conductor Insulation Jacket Overall Netof Diameter Thickness Thickness Diameter Weight

AWGkcmilStrands Inch mils mils inch lbMft

8 7 015 45 15 026 79

6 7 118 45 30 042 125

4 7 023 45 30 038 179

2 7 029 45 30 043 269

10 19 037 55 45 056 432

20 19 041 55 45 061 528

30 19 047 55 45 066 647

40 19 052 55 45 071 797

250 37 057 65 45 082 982

300 37 062 65 65 087 1146

352 37 067 65 65 092 1351

400 37 072 65 65 097 1480

500 37 080 65 65 105 1782

600 61 088 80 65 116 2186

750 61 098 80 65 126 2685

1000 61 114 80 65 141 3410

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

reg reg

15

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

CODE SIZE STRAND OVERALL DIAMETER NET WEIGHT RUPTURE STRENGTH

Turkey 6 61 0198 503 36 54

Swan 4 61 0250 635 58 86

Swallow 3 61 0281 714 73 108

Sparrow 2 61 0316 803 91 136

Robin 1 61 0355 902 115 171

Raven 10 61 0398 1011 145 216

Quail 20 61 0447 1135 183 273

Pigeon 30 61 0502 1275 231 344

Penguin 40 61 0563 1430 291 433

Partridge 2668 267 0642 1631 366 544

Linnet 3364 267 0721 1831 162 688

Oriole 3364 307 0741 1882 525 782

Ibis 3975 267 0783 1989 545 811

Lark 3975 307 0806 2047 619 921

Hawk 4770 267 0858 2179 654 973

Hen 4770 307 0883 2243 743 1106

Heron 5000 307 0904 2296 781 1162

Dove 5565 267 0927 2355 765 1138

Eagle 5565 307 0953 2421 869 1293

Duck 6050 547 0953 2421 779 1159

Grosbeak 6360 267 0990 2515 872 1298

Starling 7155 267 1051 2670 986 1467

Crow 7155 547 1035 2629 918 1366

Drake 7950 267 1108 2814 1095 1629

Condor 7950 547 1093 2776 1021 1520

Canary 9000 547 1162 2951 1160 1726

Rail 9540 457 1165 2959 1076 1601

Bluejay 11130 457 1259 3198 1256 1869

11903

18608

23040

28575

35550

43875

53100

66825

84308

113175

141075

173250

163125

203175

195075

238500

247500

227250

279000

234000

252000

283500

261000

315000

281250

323370

258750

309870

WORD AWG or MCM ALSteel Inch mm Lbsmft kgkm lbs

manufacturing tolerances

Condumex can currently produce a wider

BARE ACSR CABLE

ALUMINUM CONDUCTOR STEEL REINFORCED

26ACSR01

DESCRIPTION

CONDUCTORS

Aluminum 1350 wire concentrically laid overa solid or stranded galvanized steel core

Mechanical design requirements5) Good corrosion resistance

3) High resistance to mechanical strength4) Wide variety of sizes available in long

lengths to suit both electrical and

fewer towers required

strength to permit the longest possiblespans

2) Minimum sag between supports with

1) Ideal combination of conductivity and

FEATURES

Code Word quantity required in weight

ACSR cable size Aluminum Association

HOW TO ORDER

Overhead transmission subtransmission

overhead electrical cables Messenger and

overhead lines Messenger cables to support

APPLICATION

and distribution systems Static wires to protect

power support conductor in catenary systems

for railroad electrification

SPECIFICATIONS

ASTM B498 Galvanized steel class A

ASTM B232 Conductor overall

SPECIFICATIONS

ASTM B230 Aluminum wires

MAXIMUM CONDUCTOR TEMPERATURE

Normal Operation 75 degC

116

Dimension and weights shown are nominal unless otherwise indicated and subject to

range of products then what is listedPlease contact us for other items

Grand Prairie Texas800-925-9473

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
Page 2: 5Power Cable Specs Set 2 - Condumex  · PDF fileCondumex Wire and Cable 2590 114th Street, ... Type Conductors Diameter Ampacity Weight AWG ... 6 19 26.2 0.18 30 6 0.26

July 28 2009

CONDUMEX INCORPORATEDWIRE amp CABLE PRODUCT INDEX

MTWTHHNTHWN 600 VOLTS COPPER 14 AWG SOLID 750 MCM STRANDED UL 83 XHHW-2 600 VOLTS COPPER 14 AWG 1000 MCM STRANDED UL 44 RHH-RHW-USE 600 VOLTS COPPER (XLP) 6 AWG 1000 MCM STRANDED UL 44 MC Cable XHHW or XHHW-2 600 VOLTS ALUMINUM

BUILDING WIRE

TYPE TCTHHN 600 VOLTS COPPER 14 AWG STRANDED 750 MCM STRANDED 3 ANDOR 4 CONDUCTOR WITH OR WITHOUT BARE GROUND WIRE (SIZES 8 AWG AND LARGER) UP TO 16 CONDUCTOR

FOR SIZES 14 12 AND 10 AWG UL 1277 ldquoERrdquo LISTED TYPE TCXHHW-2 600 VOLTS COPPER 14 AWG STRANDED 750 MCM

STRANDED 3 ANDOR 4 CONDUCTOR WITH OR WITHOUT BAREGROUND WIRE (SIZES 8 AWG AND LARGER) UP TO 16 CONDUCTORFOR SIZES 14 12 AND 10 AWG UL 1277 ldquoERrdquo LISTED

TYPE TCXHHW-2 600 VOLTS COPPER 10 TO 14 AWG STRANDEDUP TO 19 CONDUCTOR ON 12 AND 14 AWG AND 12 CONDUCTORS ON 10 AWG UL LISTED FOR ldquoERrdquo AND DIRECT BURIAL

TRAY CABLE

POWER CABLE PRIMARY URD CABLES 15 KV 35 KV 100 amp 133 INSULATION

LEVELS COPPER OR ALUMINUM CONDUCTOR EPR OR TR-XLP INSULATION CONCENTRIC COPPER WIRE NEUTRAL WITH OR WITHOUT ENCAPSULATING JACKET OVERALLSPECIFICATIONS ICEA S-94-649 amp AEIC CS8

TYPE MV-90 amp MV-105 (EPR INSULATION ONLY FOR MV-105) POWER CABLE 5 KV - 35 KV 100 amp 133 INSULATION LEVELS COPPER CONDUCTOR EPR OR XLP INSULATION COPPER DRAIN WIRE OR COPPER TAPE METALLIC SHIELD BLACK PVC SUNLIGHT RESISTANT JACKET SINGLE CONDUCTOR CONSTRUCTIONLISTED UL 1072 SPECIFICATIONS ICEA S-93-639 amp AEIC CS8

TYPE MC ARMORED CABLES 600 VOLTS 5 KV - 15 KV MULTI-CONDUCTOR STRANDED COPPER EPR OR XLP INSULATION ALUMINUM OR GALVANIZED STEEL INTERLOCKED ARMOR PVC SUNLIGHT RESISTANT JACKET OVERALL UL 1569

HIGH VOLTAGE POWER CABLES UP TO 138 KV COPPER OR ALUMINUM CONDUCTOR XLP UNSULATION METALLIC SHIELDPVC JACKETSPECIFICATION AEIC Cs7

BARE OVERHEAD CONDUCTORS TYPES AAC AND ACSR PER ASTM B230 amp B232 VULCANEL EPR ANTILLAMA CABLE 600 VOLT NETWORK CABLE

SPECIAL PURPOSE CABLES

TYPE RHH-RHW 2000 VOLTS (DLO) SINGLE CONDUCTOR TINNED COPPER ROPE-LAY STRANDED EPR INSULATION SEPARATOR BLACK CSPE JACKET CONDUCTOR SIZES 4 AWG 1 AWG UL LISTED AS VW-1 SIZES 10 AWG 9292 MCM UL LISTED FOR ldquoCT USErdquo CSA LISTED AS FT4 SIZE 1111 MCM IS PER ICEA S-95-658

Condumex Wire and Cable th 2590 114 Street - Grand Prairie TX 75050 - (800) 925-947311-05

Notes

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947304-11

HOW TO ORDER

MC Armalat Vinilat Nylon Cable TypeTHHNTHWN gauge and length

DESCRIPTION

identification Types THHN-THWN

1) Soft annealed wire or stranded class C

copper conductor

2) PVC insulationNylon jacket with color

APPLICATION

Dry Locations (THHN Type) 90deg C

High resistance to heat and moisture

Good resistance to gasoline and oil

UL-1569

Flame retardance

SPECIFICATIONS

impact and abrasion3)The armor makes the cable resistant to

4) Type THHNTHWN offers

2) Aluminum interlock armor provides greatinstallations

Metal Clad Cable

Wet Locations (THWN Type) 75deg C

Flexibility

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

MAXIMUM OPERATING VOLTAGE

1) Easy installation on exposed or concealed

FEATURES

14 Solid 2 0242rdquo 0414rdquo 25 97

14 Solid 3 0269rdquo 0442rdquo 25 117

14 Solid 4 0302rdquo 0475rdquo 25 137

12 Solid 2 0277rdquo 0450rdquo 30 126

12 Solid 3 0309rdquo 0482rdquo 30 154

12 Solid 4 0347rdquo 0520rdquo 30 183

10 Solid 2 0346rdquo 0519rdquo 40 178

10 Solid 3 0386rdquo 0559rdquo 40 221

10 Solid 4 0434rdquo 0606rdquo 40 266

8 Stranded 2 0492rdquo 0664rdquo 55 259

8 Stranded 3 0549rdquo 0721rdquo 55 332

8 Stranded 4 0617rdquo 0789rdquo 55 406

6 Stranded 2 0568rdquo 0741rdquo 75 361

6 Stranded 3 0634rdquo 0807rdquo 75 468

6 Stranded 4 0713rdquo 0885rdquo 75 577

Dimension and weights shown are nominal unless otherwise indicated and subject to

Size Number of Nominal Nominal Allowable NetType Conductors Diameter Diameter Ampacity Weight

AWGUnder Armor Over ArmorAWG 90 C lbMft

manufacturing tolerances

11

3) Insulated grounded conductor

4) Plastic binder tape

5) Interlocked aluminum armor

Branch feeder and service power distributionsin industrial commercial and residential buildings For power lighting control and signal circuits in generalApplications where maximum security is required as hazardous locations Class I Div 2 Class II Div 2 and Class III Div I

UL-1581

File E 115900

TM TM

TYPE MC Metal Clad Cables

THHNTHWN 600V ArmalatTM

5) Insulated ground (green) is same construction as conductors

2 Conductor black white

3 Conductor black white red

4) Conductor color code

4 Conductor black white red blue

Type MC Cable meets or excides all applicable ASTM Specifications UL standards for safety

UL-83

Armored Cable

11

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947311-10

THHN or THWN-2 600 VOLTS (MTW STRANDED)

DESCRIPTION

2) Polyvinyl chloride (PVC insulation)3) Nylon overall protective jacket

123

Dimension and weights shown are nominal unless otherwise indicated and subject to

14 1 Solid 41 006 15 5 010

12 1 Solid 65 008 15 5 012

10 1 Solid 103 010 20 5 015

14 19 41 007 15 5 012

12 19 65 009 15 5 014

10 19 103 011 20 5 017

8 19 165 015 30 5 023

6 19 262 018 30 6 026

4 19 417 023 40 6 034

3 19 526 026 40 7 036

2 19 663 029 40 7 039

1 19 837 032 50 7 045

10 19 106 037 50 8 050

20 19 133 041 50 8 054

30 19 168 047 50 8 059

40 19 211 052 50 8 065

250 37 057 60 9 072

300 37 062 60 9 078

350 37 067 60 9 083

400 37 072 60 9 087

500 37 080 60 9 096

600 61 088 70 10 106

750 61 098 70 10 115

1000 61 114 70 10 127

16

23

37

17

26

40

65

99

157

197

241

306

380

472

587

729

870

1033

1196

1359

1685

2023

2454

3347

Size Number Conductor Conductor Insulation Jacket OverallAWG of Area Diameter Thickness Thickness Diameterkcmil Strands kcmil mils mils mils inch

NetWeightlbmft

manufacturing tolerances

VINILAT Nylon solid or stranded typereg

General use in commercial and industrial

SPECIFICATIONS

construction and installations whereresistance against oils and gasoline is

APPLICATION

75deg CIn oil (Oil resistant II)

6) Superior abrasion and mechanical properties7) Sizes 10 and larger are marked For CT use and are approved for installation

overload exists

in cable trays Sunlight resistant in Accordance with NEC Article 318

manufacturing process4) Flame retardant UL listed as VW-15) Smooth nylon jacket aids in easier pulling

1) Good resistance to moisture heat oil gasoline chemicals and grease2) Suitable for installation where thermal

3) Strict quality control during

FEATURES

MAXIMUM CONDUCTOR TEMPERATURE

Dry locations (THHN)Dry and wet locations (THWN-2)

90deg C90deg C

MAXIMUM OPERATING VOLTAGE

600 volts

required May be used for power and

gases gasoline and chemicals Alsosuitable as machine tool and switchboard

control circuits in recognized raceways inwet or dry locations and in presence of

wiring

UL-83

HOW TO ORDER

NATIONAL ELECTRICAL CODE REFERENCE

Ampacities

Switchboard wiring

Conduit fill tables

Article 3 10-15

Article 384

Chapter 9

THHN or THWN-2 600 volts size color and length

12

RoHS

IEEE 1202 and ULFT4 Flame Test

CESMEC E-022-01-5505

Type THHN or THWN-2 Annealed bare solid (14-10 AWG) type THHN or THWN-2 Annealed bare stranded class C concentric round (14-2 AWG) compressed stranding class B (1 AWG-1000MCM)copper conductor

1)

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947311-10

XHHW-2 600 VOLTS

POWER CABLE TYPE TC

DESCRIPTION

Dimension and weights shown are nominal unless otherwise indicated and subject to

Size Number Number Jacket Overall Netof of Thickness Diameter WeightAWG

Strands Conductors mils inches lbMft

2 45 033 65

3 45 035 81

4 45 038 103

14 7 5 45 042 125

7 60 049 182

9 60 060 230

12 60 067 288

19 80 077 455

2 45 041 84

3 45 043 112

4 45 047 140

5 45 051 172

12 7 7 60 063 247

9 60 073 310

12 60 081 397

19 80 098 626

2 45 046 97

3 45 048 125

4 60 057 173

10 7 5 60 062 209

7 60 071 279

9 60 081 350

12 80 095 481

manufacturing tolerances

FEATURES

Wet or DryDry

90deg C90deg C

APPLICATION

Electrical Code

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet ordry locations and in the presence of oil and most

lighting control signal and communcation circuitsin raceways direct burial in earth or in

SPECIFICATIONS

S-73-532 (table E-2 or Method SB 4)7) Circuit identification color coded per ICEA

UL 1277 UL 44

HOW TO ORDER

chemicals in accordance with the National

MAXIMUM OPERATING VOLTAGE

600 volts

MAXIMUM CONDUCTOR TEMPERATURE

Condumex Tray Cable Type TCXHHW-2

600 volts number and size of conductors

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

BTU flame test3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

Electrical Code

tray cable used in accordance with the National

Resistant I

O5) PVC jacket is UL rated 90 C and listed Oil

Location Applications6) Acceptable for Class I Division 2 Hazardous

7a) Other color coding methods are available based on ICEA S-73-532

24 13

1) Annealed bare Class C concentric strand copper conductors2) Flame retardant XLPE3) Binder tape over core4) Overall flame retardant PVC jacket

Contact factory for items not shown above

8) ldquoERrdquo Listed per UL 1277

1113

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947311-10

THHNTHWN 600 VOLTS

POWER CABLE TYPE TC

DESCRIPTION

2) Polyvinyl Chloride (PVC) thermoplastic

insulation

1) Annealed bare Class C concentric

strand copper conductors

3) Nylon protective covering

4) Binder tape over core

5) Overall flame retardant PVC jacket

Dimension and weights shown are nominal unless otherwise indicated and subject to

Size Number Number Jacket Overall Netof of Thickness Diameter WeightAWG

Strands Conductors mils inches lbMft

2 45 034 68

3 45 036 87

4 45 040 109

14 19 5 45 043 130

7 45 046 167

9 60 056 234

12 60 063 285

16 60 067 335

2 45 038 90

3 45 040 119

4 45 043 154

5 45 046 173

12 19 7 60 055 247

9 60 064 326

12 60 071 400

16 60 076 485

2 45 045 139

3 45 047 180

4 60 055 247

10 19 5 60 060 178

7 60 065 367

9 60 075 480

12 80 089 637

manufacturing tolerances

FEATURES

Wet or DryDry

75deg C90deg C

APPLICATION

Electrical Code

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet ordry locations and in the presence of oil and most

lighting control signal and communcation circuitsin raceways direct burial in earth or in

SPECIFICATIONS

S-73-532 (table E-2 or Method SB 4)7) Circuit identification color coded per ICEA

UL 1277 UL 83 and ER Approved

HOW TO ORDER

chemicals in accordance with the National

MAXIMUM OPERATING VOLTAGE

600 volts

MAXIMUM CONDUCTOR TEMPERATURE

Condumex Tray Cable Type TCTHHN

600 volts number and size of conductors

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

BTU flame test3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

Electrical Code

tray cable used in accordance with the National

Resistant I

O5) PVC jacket is UL rated 90 C and listed Oil

required metallic sheathed cablessubstantial cost savings over the previouslyLocation Applications Type TX offers

6) Acceptable for Class I Division 2 Hazardous

7a) Other color coding methods are available based on ICEA S-73-532

4

245 13

8) ldquoERrdquo Listed per UL 1277

RoHS

5) Binder tape over core

750 kcmil) copper conductors

6) Overall flame retardant PVC jacket

DESCRIPTION

3) Nylon protective covering4) Fillers

1) Annealed bare Class C (8-2 AWG)compressed stranded Class B (10 AWG-

2) Polyvinyl Chloride thermoplastic insulation

36 145 2

POWER CABLE TYPE TC

THHNTHWN 600 VOLTS

Size Number Ground Insulation Jacket Overall Netof Conductor Thickness Thickness Diameter Weight

AWGkcmilConductors AWG mils mils inch lbMft

8 3 10 305 60 0638 338

6 3 8 305 60 0698 448

4 3 6 407 80 0884 693

2 3 6 407 80 1015 1012

1 3 8 507 80 1150 1210

10 3 6 508 80 1223 1495

20 3 6 508 80 1320 1858

30 3 4 508 80 1428 2297

40 3 4 508 80 1549 2791

250 3 4 609 80 1760 3374

350 3 3 609 110 1980 4526

500 3 2 609 110 2260 6230

750 3 1 7010 110 2967 8845

10 4 6 508 80 1350 1913

20 4 6 508 80 1457 2311

40 4 4 508 110 1773 3597

350 4 3 609 110 2188 5754

500 4 2 609 110 2502 8018

750 4 1 7010 140 3057 11716

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

MAXIMUM OPERATING VOLTAGE

UL 1277 UL 83 and ER Approved

7) Circuit identification color coded per ICEA

MAXIMUM CONDUCTOR TEMPERATURE

Wet or DryDry

75deg C90deg C

required metallic sheathed cables

3) Sunlight resistant can be installed outdoors

tray cable use in accordance with the National

Electrical Code

APPLICATION

in accordance with the National Electrical Code

6) Acceptable for Class I Division 2 Hazardous

4) UL listed as Type TC for power and control

600 volts

5) PVC jacket is UL rated 90deg C and listed Oil

Resistant I

1) UL listed for direct burial

2) Flame retardant (passes UL 1277 70000

BTU flame test)

FEATURES

Condumex Type TC cable may be used for

cable may be used in wet or dry locations and in the presence of oil and most chemicals

power lighting control signal and communication circuits in raceways direct

HOW TO ORDER

600 volts number and size of conductorsCondumex Tray Cable Type TCTHHN

SPECIFICATIONS

S-73-532 (table E-2 or Method SB 4)

Location Applications Type TC offers

substantial cost savings over the previously

7a) Other color coding methods are available based on ICEA S-73-532

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947303-06

5

8) ldquoERrdquo Listed per UL 1277

RoHS

1) Annealed bare stranded class B compact

copper conductor

DESCRIPTION

3) Ethylene propylene (EPR) or cross-linked

polyethylene (XLPE) insulation

4) Polyvinyl chloride (PVC) protective jacket

2) Extruded semiconducting strand shield

VULCANELreg MEDIUM VOLTAGE

WET OR DRY POWER CABLE 5 KVXLPE OR EPR NON-SHIELDED

24 13

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

Size Number Conductor Insulation Insulation Jacket OverallAWG of Diameter Thickness Diameter Thickness Diameterkcmil Strands inch inch inch mils Inch XLPE EPR

Net WeightLbMft

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

manufacturing tolerances

5kV 133 Insulation Level 115 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject to

cable voltage and insulation level conductor

Ampacities

Cable Trays

Type MV

ICEA S-66-524 AEIC CS-S (XLP)

extrusion) results in a virtually perfect cable core

- Very low dielectric loss

Normal Operation 105deg C130deg CEmergency Overload

VULCANELreg 5kv Non-shielded power cables

adequate for proper termination of the shielding

1) Simultaneous extrusion of strand shield

250deg CShort Circuit

UL 1072

326

318

310-15

National Electrical Code References

VULCANELreg EPRXLPE Non-Shielded power

size and type length and reel dimensions

SPECIFICATIONS

are ideally suited for use in industrial andutility applications where shields cannot be

APPLICATION

abrasion ozone and moisture

- Electrical stability under stress- Low dielectric loss- Chemical resistance

FEATURES

3) Easy-stripping insulation shield4) The external PVC jacket is resistant to

EPR insulation offers- Excellent heat moisture and corona

2) XLPE insulation offers- Low moisture absorption- Good resistance to chemicals

insulation and insulation shield (triple

accordance with the National ElectricalCode

5) UL listed as MV-105 sunlight resistantdirect burial Optional marking For CTuse available on single conductor in

HOW TO ORDER

resistance

MAXIMUM CONDUCTOR TEMPERATURE

Page 1 of 2

ICEA S-68-516 AEIC CS-6-87 (EPR)

6

RoHS

VULCANELreg MEDIUM VOLTAGE

WET OR DRY POWER CABLE 5 KVXLPE OR EPR NON-SHIELDED

Page 2 of 2

Size Number Conductor Insulation Insulation Jacket OverallAWG of Diameter Thickness Diameter Thickness Diameterkcmil Strands inch inch inch mils Inch XLPE EPR

Net WeightlbMft

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

25kV 100 Insulation Level 260 mils Insulation Thickness

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

35kV 100 Insulation Level 345 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

15kV 133 Insulation Level 220 mils Insulation Thickness

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

17

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANELreg MEDIUM VOLTAGE EPR

SHIELDED POWER CABLES 5 15 25 35 KV

346 125

DESCRIPTION

1) Annealed bare stranded class B compactcopper conductor

2) Extruded semiconducting strand shield3) Ethylene propylene rubber (EPR) insulation4) Extruded semiconducting insulation shield5) Annealed copper tape shield (25 overlap

6) Polyvinyl chloride (PVC) protective jacketminimum)

Three-phase electrical distribution systems

trays

Suitable for use in overhead installationsrecognized raceways direct burial or cable

APPLICATION

voltage and insulation level conductor

AmpacitiesCable TraysType MV

- Chemical resistance

5) The external PVC jacket is resistant to

- Electrical stability under stress

MAXIMUM CONDUCTOR TEMPERATURE

SPECIFICATIONS

use available on single conductor in

accordance with the National ElectricalCode

abrasion ozone and moisture6) UL listed as MV-105 sunlight resistant

direct burial Optional marking For CT

3) Easy-stripping insulation shield4) Tape shield provides high short circuit

capabilities and uniform shield impedance

- Low dielectric loss

UL 1072

size and type length and reel dimensions

ICEA S-68-516 AEIC CS6-87

326318310-15

National Electrical Code References

VULCANELreg EPR shielded power cable

2) EPR insulation offers- Excellent heat moisture and corona

resistance

insulation and insulation shield (tripleextrusion) results in a virtually perfect

cable core

250 degCShort Circuit

1) Simultaneous extrusion of strand shield

Normal Operation 105 degC130 degCEmergency Overload

FEATURES

SPECIFICATIONS

HOW TO ORDER

Page 1 of 2

Size Number Conductor Insulation Insul Shld Jacket Overall Netof Diameter Thickness Diameter Thickness Diameter Weight

AWGkcmilStrands Inch inch inch mils Inch lbMft

6 7 017 045 053 60 067 290

4 7 022 049 057 60 071 357

2 7 027 055 063 60 074 478

10 19 034 062 070 80 085 668

20 19 038 066 074 80 092 775

30 19 043 071 079 80 097 933

40 19 048 076 084 80 102 1071

250 37 052 081 090 80 107 1226

350 37 062 091 099 80 117 1560

500 37 074 103 113 80 132 2150

750 61 091 121 132 80 150 3027

1000 61 111 136 146 80 164 3845

5kV 133 Insulation Level 115 mils Insulation Thickness

2 7 027 067 075 80 093 570

10 19 034 074 082 80 100 736

20 19 038 078 086 80 104 849

30 19 043 083 091 80 109 1010

40 19 048 088 096 80 114 1190

250 37 052 094 102 80 120 1330

350 37 062 103 114 80 132 1753

500 37 074 116 126 80 144 2280

750 61 091 134 144 80 162 3142

1000 61 111 136 159 110 183 5794

5kV 100 Insulation Level 175 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

Page 2 of 2

VULCANELreg MEDIUM VOLTAGE EPR

SHIELDED POWER CABLES 5 15 25 35 KV

Size Number Conductor Insulation Insul Shld Jacket Overall Netof Diameter Thickness Diameter Thickness Diameter Weight

AWGkcmilStrands Inch inch inch mils Inch lbMft

6 7 017 045 053 60 067 290

4 7 022 049 057 60 071 357

2 7 027 055 063 60 074 478

10 19 034 062 070 80 085 668

20 19 038 066 074 80 092 775

30 19 043 071 079 80 097 933

40 19 048 076 084 80 102 1071

250 37 052 081 090 80 107 1226

350 37 062 091 099 80 117 1560

500 37 074 103 113 80 132 2150

750 61 091 121 132 80 150 3027

1000 61 111 136 146 80 164 3845

15kV 133 Insulation Level 220 mils Insulation Thickness

10 19 034 092 100 80 118 894

20 19 038 096 104 80 122 1009

30 19 043 100 111 80 129 1181

40 19 048 106 116 80 134 1394

250 37 052 111 122 80 140 1537

350 37 062 121 131 80 149 1936

500 37 074 133 143 80 161 2516

750 61 091 151 161 110 185 3620

1000 61 111 166 180 110 204 4543

25kV 100 Insulation Level 260 mils Insulation Thickness

10 19 034 109 119 80 137 1041

20 19 038 113 123 80 141 1226

30 19 043 118 128 80 146 1380

40 19 048 123 133 80 151 1569

250 37 052 129 139 80 157 1750

350 37 062 138 149 80 167 2163

500 37 074 150 161 110 185 2893

750 61 091 168 183 110 207 3900

1000 61 111 183 197 110 221 4807

35kV 100 Insulation Level 345 mils Insulation Thickness

manufacturing tolerancesDimension and weights shown are nominal unless otherwise indicated and subject to

19

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-94735-05

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

ICEA-S-68-516

SPECIFICATIONS

three conductor cable voltage size andlength

Condumex Mining Cable EPR type SHD-GC

HOW TO ORDER

MINING CABLE EPR TYPE SHD-GC

THREE CONDUCTOR 5000 VOLTS

18SHD-GC01

with a nylon webbing provides a tough defense

round configuration

and Health Administration Approval No P-218-1-MSHA

by the Pennsylvania Department of Environmental

Resources Meets MSHA flame test requirements

6) Acceptance No P-218-1-MSHA by Mines Safety

5) CV-Cured extra-heavy-duty CPE reinforced

4) Prevulcanized thermosetting non-wicking fillers

mechanical resistant jacket

resistance outstanding corona resistance

high dielectric strength and chemical resistance

designed for flexibility and resistance to

FEATURES

2) Ground check conductor facilitates fail-safe

3) EPR insulation offers excellent heat and moisture

are used if necessary to obtain a substantially

1) Special tinned copper stranded conductors

fatigue resulting from bending and flexing

ground monitoring for maximum safety

Dimension and weights shown are nominal unless otherwise indicated and subject to

6 7x3029 020 110 10 8 156

4 7x4729 025 110 8 8 168

2 7x7429 031 110 6 8 187

1 7x3725 035 110 5 8 195

10 7x4725 039 110 4 8 208

20 7x6025 045 110 3 8 220

30 7x7525 050 110 2 8 236

40 19x3525 059 110 1 8 250

300 19x4925 069 120 10 8 281

350 19x5825 076 120 20 8 295

1675

1888

2322

2653

3068

3504

4206

5023

6371

7654

Size Number of Conductor Insulation Ground Ground OverallAWG Strands Diameter Thickness Size Check Size Diameterkcmil AWG inch mils AWG AWG inch

NetWeightlbmft

manufacturing tolerances

MAXIMUM CONDUCTOR TEMPERATURE

Normal continuous 90deg C130deg COverload

250deg CShort circuit

MAXIMUM OPERATING VOLTAGE

5000 volts

Trailing cable on ac mining equipment

where service conditions are severe andmaximum safety is mandatory such as

APPLICATION

power shovels and draglines in open-pit

mines quarries gantry cranes and slag

reclaiming Also used for medium voltage

distribution in underground mines where

frequent relocation is necessary

DESCRIPTION

1) Three flexible annealed tinned copper rope-lay stranded conductors

2) Extruded semi-conducting conductor shieldand ethylene propylene rubber (EPR) insulation

3) Color coded cottoncopper braid shield applied over semi-conducting tape

4) Two annealed tinned copper rope-lay strandedgrounding conductors

5) Annealed tinned copper rope-lay stranded

and covered with a yellow cotton braid

chlorinated polyethylene (CPE) jacket

6) Rubberized cotton binder tape7) Nylon web reinforced extra-heavy-duty

ground check conductor yellow EPR insulation

346 2 157

110

RoHS

5) Overall flame retardant PVC jacket

DESCRIPTION

XLP insulation3) Fillers (if required)

4) Binder tape over core

2) Cross-Linked polyethylene thermosetting

1) Annealed bare stranded compressed

Class B copper conductors

without grounding conductorVolts number and size of conductors with or

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet

lighting control signal and communication circuitsin cable trays raceways direct burial or on

HOW TO ORDER

Condumex Tray Cable Type TCXHHW 600

SPECIFICATIONS

UL-1277 amp UL-44

APPLICATION

most chemicals in accordance with the

MAXIMUM OPERATING VOLTAGE

National Electrical Code

or dry locations and in the presence of oil and

6) Acceptable for Class 1 Division 2 HazardousLocations applications

O5) PVC jacket is UL rated 90 C and listed OilResistant I

600 volts

MAXIMUM CONDUCTOR TEMPERATUREO 90 C

O130 C

FEATURES

OverloadNormal

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

National Electrical Code

BTU flame test)3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

tray cable use in accordance with the

3 145 2

POWER CABLE TYPE TC

XHHW 600 VOLTS

Size Number Ground Insulation Jacket Overall Netof Conductor Thickness Thickness Diameter Weight

AWGkcmilConductors AWG mils mils inch lbMft

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 3 10 45 60 066 310

6 3 8 45 60 074 448

4 3 8 45 80 088 659

2 3 6 45 80 103 968

10 3 6 55 80 121 1428

20 3 4 55 80 131 1735

30 3 4 55 80 142 2150

40 3 4 55 80 154 3620

250 3 4 65 110 175 3190

350 3 3 65 110 196 4305

500 3 2 65 110 225 5940

8 4 10 45 60 073 385

6 4 8 45 80 083 568

4 4 8 45 80 097 832

2 4 6 45 80 112 1230

10 4 6 5 80 134 1825

20 4 4 55 80 145 2212

30 4 4 55 80 157 2751

40 4 4 55 110 177 3462

250 4 4 65 110 198 4097

350 4 3 65 110 217 5542

500 4 2 65 110 249 7690

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

111

7) ldquoERrdquo Listed per UL 1277

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

National Electrical Code References

Product Article 310 Table 310-13

Ampacities Article 310-15

HOW TO ORDER

CONDUMEX type RHH-RHW-USE-2

XLPE 600 volts size length quantity

packaging

DESCRIPTION

polyethylene (XLPE) insualtion

1) Annealed bare stranded class B

conductor

2) Flame-retardant cross-linked

TYPE RHH-RHW-USE-2

COPPER XLPE 600 VOLTS

APPLICATION

May be installed in free air all raceways or

underground service entrance cable

Type RHH 90deg C Dry and

temperatures

6) Stable electrical propoerties

UL-44 Standard for Rubber-Insulated

use in direct burial in industrial andcommercial application May be used as

7) Extremely tough

SPECIFICATIONS

4) Good resistance to most oils and

3) UL approved as VW-1 (RHH or RHW)

chemicals5) Suitable for installation in sub-zero

2) UL listed as types RHH or RHW or USE forresistant insulation

damp locations

ICEA S-66-524 Standard for Cross-Linked

Type RHW or 75deg C Dry and

use in accordance with the National

Electrical Code

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

MAXIMUM OPERATING VOLTAGE

USE wet locatinons

1) Flame retardant moisture and heat

FEATURES

Wires and Cables

Polyethylene Insualted Wire and Cable

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch mils inch lbMft

8 7 165 015 60 027 73

6 7 262 018 60 031 108

4 7 417 022 60 035 161

2 7 663 028 60 041 245

10 19 106 036 80 053 392

20 19 133 041 80 058 485

30 19 168 046 80 063 600

40 19 211 051 80 069 746

250 37 056 95 076 887

300 37 061 95 082 1052

350 37 066 95 087 1216

400 37 071 95 092 1380

500 37 079 95 099 1708

600 61 087 110 111 2055

750 61 097 110 120 2542

1000 61 112 110 136 3353

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

11 112

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

copper conductor

2) Cross-linked polyethylene (XLPE)

insulation

compressed (6 AWG-1000 MCM)

1) Annealed bare stranded class B

concentric round (14-8 AWG)

APPLICATION

Power or control circuits in recognized

switchboard wiring

Dry locations 90deg C

presence of oil Also suitable as

designs

temperatures

4) Suitable for installation in sub-zero

pulling and greater conduit fill

5) Optical For CT use marking for use in

cable trays Sunlight resistant in

FEATURES

2) Good moisture resistance

raceways in wet or dry location and in

90deg CWet locationsOverload 130deg CShort Circuit

MAXIMUM OPERATING VOLTAGE

3) Good resistance to most oils and

chemicals

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

accordance with NEC Article 3186) Available in VW-1 and non VW-1

UL-44

SPECIFICATIONS

Chapter 9

250deg C

1) Smaller overall diameter for easier

HOW TO ORDER

National Electrical Code References

Article 310

VULCANELreg XLPE cable type XHHW-2600 volts size and length

Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL

TYPE XHHW-2 600 VOLTS

reg XLPE CABLE

2 1

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch Mils inch lbMft

manufacturing tolerances

14 7 41 007 30 013 19

12 7 65 009 30 015 48

10 7 103 011 30 017 42

8 7 165 015 45 024 71

6 7 262 018 45 027 98

4 7 417 023 45 032 153

2 7 663 029 45 038 241

10 19 1060 037 55 048 378

20 19 1330 041 55 052 446

30 19 1680 047 55 058 556

40 19 2110 052 55 063 697

250 37 057 65 070 851

300 37 062 65 075 997

350 37 067 65 080 1180

400 37 072 65 085 1306

500 37 080 65 093 1662

600 61 088 80 104 1974

750 61 098 80 115 2450

1000 61 114 80 130 3240

Dimension and weights shown are nominal unless otherwise indicated and subject to

13

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

APPLICATION

FEATURES

MAXIMUM OPERATING VOLTAGE

MAXIMUM CONDUCTOR TEMPERATURE

UL-44

SPECIFICATIONS

Chapter 9

HOW TO ORDER

National Electrical Code References

Article 310Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL S8000

XHHW or XHHW-2 600 VOLTS ALUMINUM

reg XLPE CABLE

manufacturing tolerances

Size Number Insulations Overall Netof Thickness Diameter Weight

AWGkcmilStrands Mils In LbMft

6 7 45 027 42

4 7 45 031 59

2 7 45 036 88

1 7 55 042 111

10 19 55 045 136

20 19 55 049 165

30 19 55 054 203

40 19 55 059 250

250 37 65 066 300

300 37 65 071 354

350 37 65 075 405

500 37 65 087 562

600 61 80 098 684

750 61 80 108 840

900 61 80 117 995

Dimension and weights shown are nominal unless otherwise indicated and subject to

2 13

1) Stranded compact class B AA-8000 series aluminum alloy soft conductor2) Separator tape3) Cross-linked polyethylene (XLPE) insulation type XHHW or XHHW-2

Branch-circuits and feeders conductors in low voltage for buildings schools auditoriums hospitals stadiums museums poultry farms etc Industrial and commercial buildings For use in cable trays or raceways in wet and dry locations

600 volts

Wet and dry continuousOverloadShort circuit

90 C130 C125 C

1) Easier pulling and greater conduit fill2) Good moisture resistance3) Excellent dielectrics properties4) Continuous 90 C operating temperature in wet or dry locations5) Suitable for use in cable trays (10 AWG and greater)6) VW-1 compliant7) Sunlight resistant insulatedRoHS compliant

APPROVALS

Type XHHW or XHHW-2 UL listedType Rw90 or RWU90 upon special request

Vulcanel S8000 cable type XHHW or XHHW-2 RoHS CT-SR with stranded compact class B AA-8000 series aluminum alloy soft conductor size length and product number

reg

114

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANEL EPR ANTILLAMA CABLE

600 VOLTS

26ACSR01

DESCRIPTION

FEATURES

HOW TO ORDER

SPECIFICATIONSSPECIFICATIONS

3 2 1

1) Annealed coated or un-coated stranded class B copper conductor2) Ethylene propylene rubber (EPR) insulation3) Chlorosulfonated polyethylene (Hypalon) or chlorinated polyethylene(CPE) jacket

APPLICATION

Ideally suited for use in Electrical generating stations May be installed in free air all raceways or direct burial

MAXIMUM CONDUCTOR TEMPERATUREDry LocationsDry and Wet LocationsOverloadShort Circuit

90 C75 C130 C250 C

MAXIMUM OPERATING VOLTAGE600 Volts

1) Flame resistant Meets or exceeds requirements of IEEE 383 flame test2) Deformation resistant at high temperatures3) Excellent Flexibility at low temperature suitable for installation in sub-zero temperatures4) Extra tough mechanically rugged composite insulation and jacket construction6) Resistant to most oils and chemicals

ICEA S-95-658

VULCANEL EPR ANTILLAMA cable 600 volts size length National Electrical Code ReferencesAmpacities Article 31318-10Cable Trays Article 318

Dupont trade mark

reg reg

Size Number Conductor Insulation Jacket Overall Netof Diameter Thickness Thickness Diameter Weight

AWGkcmilStrands Inch mils mils inch lbMft

8 7 015 45 15 026 79

6 7 118 45 30 042 125

4 7 023 45 30 038 179

2 7 029 45 30 043 269

10 19 037 55 45 056 432

20 19 041 55 45 061 528

30 19 047 55 45 066 647

40 19 052 55 45 071 797

250 37 057 65 45 082 982

300 37 062 65 65 087 1146

352 37 067 65 65 092 1351

400 37 072 65 65 097 1480

500 37 080 65 65 105 1782

600 61 088 80 65 116 2186

750 61 098 80 65 126 2685

1000 61 114 80 65 141 3410

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

reg reg

15

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

CODE SIZE STRAND OVERALL DIAMETER NET WEIGHT RUPTURE STRENGTH

Turkey 6 61 0198 503 36 54

Swan 4 61 0250 635 58 86

Swallow 3 61 0281 714 73 108

Sparrow 2 61 0316 803 91 136

Robin 1 61 0355 902 115 171

Raven 10 61 0398 1011 145 216

Quail 20 61 0447 1135 183 273

Pigeon 30 61 0502 1275 231 344

Penguin 40 61 0563 1430 291 433

Partridge 2668 267 0642 1631 366 544

Linnet 3364 267 0721 1831 162 688

Oriole 3364 307 0741 1882 525 782

Ibis 3975 267 0783 1989 545 811

Lark 3975 307 0806 2047 619 921

Hawk 4770 267 0858 2179 654 973

Hen 4770 307 0883 2243 743 1106

Heron 5000 307 0904 2296 781 1162

Dove 5565 267 0927 2355 765 1138

Eagle 5565 307 0953 2421 869 1293

Duck 6050 547 0953 2421 779 1159

Grosbeak 6360 267 0990 2515 872 1298

Starling 7155 267 1051 2670 986 1467

Crow 7155 547 1035 2629 918 1366

Drake 7950 267 1108 2814 1095 1629

Condor 7950 547 1093 2776 1021 1520

Canary 9000 547 1162 2951 1160 1726

Rail 9540 457 1165 2959 1076 1601

Bluejay 11130 457 1259 3198 1256 1869

11903

18608

23040

28575

35550

43875

53100

66825

84308

113175

141075

173250

163125

203175

195075

238500

247500

227250

279000

234000

252000

283500

261000

315000

281250

323370

258750

309870

WORD AWG or MCM ALSteel Inch mm Lbsmft kgkm lbs

manufacturing tolerances

Condumex can currently produce a wider

BARE ACSR CABLE

ALUMINUM CONDUCTOR STEEL REINFORCED

26ACSR01

DESCRIPTION

CONDUCTORS

Aluminum 1350 wire concentrically laid overa solid or stranded galvanized steel core

Mechanical design requirements5) Good corrosion resistance

3) High resistance to mechanical strength4) Wide variety of sizes available in long

lengths to suit both electrical and

fewer towers required

strength to permit the longest possiblespans

2) Minimum sag between supports with

1) Ideal combination of conductivity and

FEATURES

Code Word quantity required in weight

ACSR cable size Aluminum Association

HOW TO ORDER

Overhead transmission subtransmission

overhead electrical cables Messenger and

overhead lines Messenger cables to support

APPLICATION

and distribution systems Static wires to protect

power support conductor in catenary systems

for railroad electrification

SPECIFICATIONS

ASTM B498 Galvanized steel class A

ASTM B232 Conductor overall

SPECIFICATIONS

ASTM B230 Aluminum wires

MAXIMUM CONDUCTOR TEMPERATURE

Normal Operation 75 degC

116

Dimension and weights shown are nominal unless otherwise indicated and subject to

range of products then what is listedPlease contact us for other items

Grand Prairie Texas800-925-9473

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
Page 3: 5Power Cable Specs Set 2 - Condumex  · PDF fileCondumex Wire and Cable 2590 114th Street, ... Type Conductors Diameter Ampacity Weight AWG ... 6 19 26.2 0.18 30 6 0.26

Condumex Wire and Cable th 2590 114 Street - Grand Prairie TX 75050 - (800) 925-947311-05

Notes

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947304-11

HOW TO ORDER

MC Armalat Vinilat Nylon Cable TypeTHHNTHWN gauge and length

DESCRIPTION

identification Types THHN-THWN

1) Soft annealed wire or stranded class C

copper conductor

2) PVC insulationNylon jacket with color

APPLICATION

Dry Locations (THHN Type) 90deg C

High resistance to heat and moisture

Good resistance to gasoline and oil

UL-1569

Flame retardance

SPECIFICATIONS

impact and abrasion3)The armor makes the cable resistant to

4) Type THHNTHWN offers

2) Aluminum interlock armor provides greatinstallations

Metal Clad Cable

Wet Locations (THWN Type) 75deg C

Flexibility

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

MAXIMUM OPERATING VOLTAGE

1) Easy installation on exposed or concealed

FEATURES

14 Solid 2 0242rdquo 0414rdquo 25 97

14 Solid 3 0269rdquo 0442rdquo 25 117

14 Solid 4 0302rdquo 0475rdquo 25 137

12 Solid 2 0277rdquo 0450rdquo 30 126

12 Solid 3 0309rdquo 0482rdquo 30 154

12 Solid 4 0347rdquo 0520rdquo 30 183

10 Solid 2 0346rdquo 0519rdquo 40 178

10 Solid 3 0386rdquo 0559rdquo 40 221

10 Solid 4 0434rdquo 0606rdquo 40 266

8 Stranded 2 0492rdquo 0664rdquo 55 259

8 Stranded 3 0549rdquo 0721rdquo 55 332

8 Stranded 4 0617rdquo 0789rdquo 55 406

6 Stranded 2 0568rdquo 0741rdquo 75 361

6 Stranded 3 0634rdquo 0807rdquo 75 468

6 Stranded 4 0713rdquo 0885rdquo 75 577

Dimension and weights shown are nominal unless otherwise indicated and subject to

Size Number of Nominal Nominal Allowable NetType Conductors Diameter Diameter Ampacity Weight

AWGUnder Armor Over ArmorAWG 90 C lbMft

manufacturing tolerances

11

3) Insulated grounded conductor

4) Plastic binder tape

5) Interlocked aluminum armor

Branch feeder and service power distributionsin industrial commercial and residential buildings For power lighting control and signal circuits in generalApplications where maximum security is required as hazardous locations Class I Div 2 Class II Div 2 and Class III Div I

UL-1581

File E 115900

TM TM

TYPE MC Metal Clad Cables

THHNTHWN 600V ArmalatTM

5) Insulated ground (green) is same construction as conductors

2 Conductor black white

3 Conductor black white red

4) Conductor color code

4 Conductor black white red blue

Type MC Cable meets or excides all applicable ASTM Specifications UL standards for safety

UL-83

Armored Cable

11

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947311-10

THHN or THWN-2 600 VOLTS (MTW STRANDED)

DESCRIPTION

2) Polyvinyl chloride (PVC insulation)3) Nylon overall protective jacket

123

Dimension and weights shown are nominal unless otherwise indicated and subject to

14 1 Solid 41 006 15 5 010

12 1 Solid 65 008 15 5 012

10 1 Solid 103 010 20 5 015

14 19 41 007 15 5 012

12 19 65 009 15 5 014

10 19 103 011 20 5 017

8 19 165 015 30 5 023

6 19 262 018 30 6 026

4 19 417 023 40 6 034

3 19 526 026 40 7 036

2 19 663 029 40 7 039

1 19 837 032 50 7 045

10 19 106 037 50 8 050

20 19 133 041 50 8 054

30 19 168 047 50 8 059

40 19 211 052 50 8 065

250 37 057 60 9 072

300 37 062 60 9 078

350 37 067 60 9 083

400 37 072 60 9 087

500 37 080 60 9 096

600 61 088 70 10 106

750 61 098 70 10 115

1000 61 114 70 10 127

16

23

37

17

26

40

65

99

157

197

241

306

380

472

587

729

870

1033

1196

1359

1685

2023

2454

3347

Size Number Conductor Conductor Insulation Jacket OverallAWG of Area Diameter Thickness Thickness Diameterkcmil Strands kcmil mils mils mils inch

NetWeightlbmft

manufacturing tolerances

VINILAT Nylon solid or stranded typereg

General use in commercial and industrial

SPECIFICATIONS

construction and installations whereresistance against oils and gasoline is

APPLICATION

75deg CIn oil (Oil resistant II)

6) Superior abrasion and mechanical properties7) Sizes 10 and larger are marked For CT use and are approved for installation

overload exists

in cable trays Sunlight resistant in Accordance with NEC Article 318

manufacturing process4) Flame retardant UL listed as VW-15) Smooth nylon jacket aids in easier pulling

1) Good resistance to moisture heat oil gasoline chemicals and grease2) Suitable for installation where thermal

3) Strict quality control during

FEATURES

MAXIMUM CONDUCTOR TEMPERATURE

Dry locations (THHN)Dry and wet locations (THWN-2)

90deg C90deg C

MAXIMUM OPERATING VOLTAGE

600 volts

required May be used for power and

gases gasoline and chemicals Alsosuitable as machine tool and switchboard

control circuits in recognized raceways inwet or dry locations and in presence of

wiring

UL-83

HOW TO ORDER

NATIONAL ELECTRICAL CODE REFERENCE

Ampacities

Switchboard wiring

Conduit fill tables

Article 3 10-15

Article 384

Chapter 9

THHN or THWN-2 600 volts size color and length

12

RoHS

IEEE 1202 and ULFT4 Flame Test

CESMEC E-022-01-5505

Type THHN or THWN-2 Annealed bare solid (14-10 AWG) type THHN or THWN-2 Annealed bare stranded class C concentric round (14-2 AWG) compressed stranding class B (1 AWG-1000MCM)copper conductor

1)

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947311-10

XHHW-2 600 VOLTS

POWER CABLE TYPE TC

DESCRIPTION

Dimension and weights shown are nominal unless otherwise indicated and subject to

Size Number Number Jacket Overall Netof of Thickness Diameter WeightAWG

Strands Conductors mils inches lbMft

2 45 033 65

3 45 035 81

4 45 038 103

14 7 5 45 042 125

7 60 049 182

9 60 060 230

12 60 067 288

19 80 077 455

2 45 041 84

3 45 043 112

4 45 047 140

5 45 051 172

12 7 7 60 063 247

9 60 073 310

12 60 081 397

19 80 098 626

2 45 046 97

3 45 048 125

4 60 057 173

10 7 5 60 062 209

7 60 071 279

9 60 081 350

12 80 095 481

manufacturing tolerances

FEATURES

Wet or DryDry

90deg C90deg C

APPLICATION

Electrical Code

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet ordry locations and in the presence of oil and most

lighting control signal and communcation circuitsin raceways direct burial in earth or in

SPECIFICATIONS

S-73-532 (table E-2 or Method SB 4)7) Circuit identification color coded per ICEA

UL 1277 UL 44

HOW TO ORDER

chemicals in accordance with the National

MAXIMUM OPERATING VOLTAGE

600 volts

MAXIMUM CONDUCTOR TEMPERATURE

Condumex Tray Cable Type TCXHHW-2

600 volts number and size of conductors

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

BTU flame test3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

Electrical Code

tray cable used in accordance with the National

Resistant I

O5) PVC jacket is UL rated 90 C and listed Oil

Location Applications6) Acceptable for Class I Division 2 Hazardous

7a) Other color coding methods are available based on ICEA S-73-532

24 13

1) Annealed bare Class C concentric strand copper conductors2) Flame retardant XLPE3) Binder tape over core4) Overall flame retardant PVC jacket

Contact factory for items not shown above

8) ldquoERrdquo Listed per UL 1277

1113

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947311-10

THHNTHWN 600 VOLTS

POWER CABLE TYPE TC

DESCRIPTION

2) Polyvinyl Chloride (PVC) thermoplastic

insulation

1) Annealed bare Class C concentric

strand copper conductors

3) Nylon protective covering

4) Binder tape over core

5) Overall flame retardant PVC jacket

Dimension and weights shown are nominal unless otherwise indicated and subject to

Size Number Number Jacket Overall Netof of Thickness Diameter WeightAWG

Strands Conductors mils inches lbMft

2 45 034 68

3 45 036 87

4 45 040 109

14 19 5 45 043 130

7 45 046 167

9 60 056 234

12 60 063 285

16 60 067 335

2 45 038 90

3 45 040 119

4 45 043 154

5 45 046 173

12 19 7 60 055 247

9 60 064 326

12 60 071 400

16 60 076 485

2 45 045 139

3 45 047 180

4 60 055 247

10 19 5 60 060 178

7 60 065 367

9 60 075 480

12 80 089 637

manufacturing tolerances

FEATURES

Wet or DryDry

75deg C90deg C

APPLICATION

Electrical Code

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet ordry locations and in the presence of oil and most

lighting control signal and communcation circuitsin raceways direct burial in earth or in

SPECIFICATIONS

S-73-532 (table E-2 or Method SB 4)7) Circuit identification color coded per ICEA

UL 1277 UL 83 and ER Approved

HOW TO ORDER

chemicals in accordance with the National

MAXIMUM OPERATING VOLTAGE

600 volts

MAXIMUM CONDUCTOR TEMPERATURE

Condumex Tray Cable Type TCTHHN

600 volts number and size of conductors

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

BTU flame test3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

Electrical Code

tray cable used in accordance with the National

Resistant I

O5) PVC jacket is UL rated 90 C and listed Oil

required metallic sheathed cablessubstantial cost savings over the previouslyLocation Applications Type TX offers

6) Acceptable for Class I Division 2 Hazardous

7a) Other color coding methods are available based on ICEA S-73-532

4

245 13

8) ldquoERrdquo Listed per UL 1277

RoHS

5) Binder tape over core

750 kcmil) copper conductors

6) Overall flame retardant PVC jacket

DESCRIPTION

3) Nylon protective covering4) Fillers

1) Annealed bare Class C (8-2 AWG)compressed stranded Class B (10 AWG-

2) Polyvinyl Chloride thermoplastic insulation

36 145 2

POWER CABLE TYPE TC

THHNTHWN 600 VOLTS

Size Number Ground Insulation Jacket Overall Netof Conductor Thickness Thickness Diameter Weight

AWGkcmilConductors AWG mils mils inch lbMft

8 3 10 305 60 0638 338

6 3 8 305 60 0698 448

4 3 6 407 80 0884 693

2 3 6 407 80 1015 1012

1 3 8 507 80 1150 1210

10 3 6 508 80 1223 1495

20 3 6 508 80 1320 1858

30 3 4 508 80 1428 2297

40 3 4 508 80 1549 2791

250 3 4 609 80 1760 3374

350 3 3 609 110 1980 4526

500 3 2 609 110 2260 6230

750 3 1 7010 110 2967 8845

10 4 6 508 80 1350 1913

20 4 6 508 80 1457 2311

40 4 4 508 110 1773 3597

350 4 3 609 110 2188 5754

500 4 2 609 110 2502 8018

750 4 1 7010 140 3057 11716

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

MAXIMUM OPERATING VOLTAGE

UL 1277 UL 83 and ER Approved

7) Circuit identification color coded per ICEA

MAXIMUM CONDUCTOR TEMPERATURE

Wet or DryDry

75deg C90deg C

required metallic sheathed cables

3) Sunlight resistant can be installed outdoors

tray cable use in accordance with the National

Electrical Code

APPLICATION

in accordance with the National Electrical Code

6) Acceptable for Class I Division 2 Hazardous

4) UL listed as Type TC for power and control

600 volts

5) PVC jacket is UL rated 90deg C and listed Oil

Resistant I

1) UL listed for direct burial

2) Flame retardant (passes UL 1277 70000

BTU flame test)

FEATURES

Condumex Type TC cable may be used for

cable may be used in wet or dry locations and in the presence of oil and most chemicals

power lighting control signal and communication circuits in raceways direct

HOW TO ORDER

600 volts number and size of conductorsCondumex Tray Cable Type TCTHHN

SPECIFICATIONS

S-73-532 (table E-2 or Method SB 4)

Location Applications Type TC offers

substantial cost savings over the previously

7a) Other color coding methods are available based on ICEA S-73-532

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947303-06

5

8) ldquoERrdquo Listed per UL 1277

RoHS

1) Annealed bare stranded class B compact

copper conductor

DESCRIPTION

3) Ethylene propylene (EPR) or cross-linked

polyethylene (XLPE) insulation

4) Polyvinyl chloride (PVC) protective jacket

2) Extruded semiconducting strand shield

VULCANELreg MEDIUM VOLTAGE

WET OR DRY POWER CABLE 5 KVXLPE OR EPR NON-SHIELDED

24 13

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

Size Number Conductor Insulation Insulation Jacket OverallAWG of Diameter Thickness Diameter Thickness Diameterkcmil Strands inch inch inch mils Inch XLPE EPR

Net WeightLbMft

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

manufacturing tolerances

5kV 133 Insulation Level 115 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject to

cable voltage and insulation level conductor

Ampacities

Cable Trays

Type MV

ICEA S-66-524 AEIC CS-S (XLP)

extrusion) results in a virtually perfect cable core

- Very low dielectric loss

Normal Operation 105deg C130deg CEmergency Overload

VULCANELreg 5kv Non-shielded power cables

adequate for proper termination of the shielding

1) Simultaneous extrusion of strand shield

250deg CShort Circuit

UL 1072

326

318

310-15

National Electrical Code References

VULCANELreg EPRXLPE Non-Shielded power

size and type length and reel dimensions

SPECIFICATIONS

are ideally suited for use in industrial andutility applications where shields cannot be

APPLICATION

abrasion ozone and moisture

- Electrical stability under stress- Low dielectric loss- Chemical resistance

FEATURES

3) Easy-stripping insulation shield4) The external PVC jacket is resistant to

EPR insulation offers- Excellent heat moisture and corona

2) XLPE insulation offers- Low moisture absorption- Good resistance to chemicals

insulation and insulation shield (triple

accordance with the National ElectricalCode

5) UL listed as MV-105 sunlight resistantdirect burial Optional marking For CTuse available on single conductor in

HOW TO ORDER

resistance

MAXIMUM CONDUCTOR TEMPERATURE

Page 1 of 2

ICEA S-68-516 AEIC CS-6-87 (EPR)

6

RoHS

VULCANELreg MEDIUM VOLTAGE

WET OR DRY POWER CABLE 5 KVXLPE OR EPR NON-SHIELDED

Page 2 of 2

Size Number Conductor Insulation Insulation Jacket OverallAWG of Diameter Thickness Diameter Thickness Diameterkcmil Strands inch inch inch mils Inch XLPE EPR

Net WeightlbMft

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

25kV 100 Insulation Level 260 mils Insulation Thickness

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

35kV 100 Insulation Level 345 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

15kV 133 Insulation Level 220 mils Insulation Thickness

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

17

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANELreg MEDIUM VOLTAGE EPR

SHIELDED POWER CABLES 5 15 25 35 KV

346 125

DESCRIPTION

1) Annealed bare stranded class B compactcopper conductor

2) Extruded semiconducting strand shield3) Ethylene propylene rubber (EPR) insulation4) Extruded semiconducting insulation shield5) Annealed copper tape shield (25 overlap

6) Polyvinyl chloride (PVC) protective jacketminimum)

Three-phase electrical distribution systems

trays

Suitable for use in overhead installationsrecognized raceways direct burial or cable

APPLICATION

voltage and insulation level conductor

AmpacitiesCable TraysType MV

- Chemical resistance

5) The external PVC jacket is resistant to

- Electrical stability under stress

MAXIMUM CONDUCTOR TEMPERATURE

SPECIFICATIONS

use available on single conductor in

accordance with the National ElectricalCode

abrasion ozone and moisture6) UL listed as MV-105 sunlight resistant

direct burial Optional marking For CT

3) Easy-stripping insulation shield4) Tape shield provides high short circuit

capabilities and uniform shield impedance

- Low dielectric loss

UL 1072

size and type length and reel dimensions

ICEA S-68-516 AEIC CS6-87

326318310-15

National Electrical Code References

VULCANELreg EPR shielded power cable

2) EPR insulation offers- Excellent heat moisture and corona

resistance

insulation and insulation shield (tripleextrusion) results in a virtually perfect

cable core

250 degCShort Circuit

1) Simultaneous extrusion of strand shield

Normal Operation 105 degC130 degCEmergency Overload

FEATURES

SPECIFICATIONS

HOW TO ORDER

Page 1 of 2

Size Number Conductor Insulation Insul Shld Jacket Overall Netof Diameter Thickness Diameter Thickness Diameter Weight

AWGkcmilStrands Inch inch inch mils Inch lbMft

6 7 017 045 053 60 067 290

4 7 022 049 057 60 071 357

2 7 027 055 063 60 074 478

10 19 034 062 070 80 085 668

20 19 038 066 074 80 092 775

30 19 043 071 079 80 097 933

40 19 048 076 084 80 102 1071

250 37 052 081 090 80 107 1226

350 37 062 091 099 80 117 1560

500 37 074 103 113 80 132 2150

750 61 091 121 132 80 150 3027

1000 61 111 136 146 80 164 3845

5kV 133 Insulation Level 115 mils Insulation Thickness

2 7 027 067 075 80 093 570

10 19 034 074 082 80 100 736

20 19 038 078 086 80 104 849

30 19 043 083 091 80 109 1010

40 19 048 088 096 80 114 1190

250 37 052 094 102 80 120 1330

350 37 062 103 114 80 132 1753

500 37 074 116 126 80 144 2280

750 61 091 134 144 80 162 3142

1000 61 111 136 159 110 183 5794

5kV 100 Insulation Level 175 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

Page 2 of 2

VULCANELreg MEDIUM VOLTAGE EPR

SHIELDED POWER CABLES 5 15 25 35 KV

Size Number Conductor Insulation Insul Shld Jacket Overall Netof Diameter Thickness Diameter Thickness Diameter Weight

AWGkcmilStrands Inch inch inch mils Inch lbMft

6 7 017 045 053 60 067 290

4 7 022 049 057 60 071 357

2 7 027 055 063 60 074 478

10 19 034 062 070 80 085 668

20 19 038 066 074 80 092 775

30 19 043 071 079 80 097 933

40 19 048 076 084 80 102 1071

250 37 052 081 090 80 107 1226

350 37 062 091 099 80 117 1560

500 37 074 103 113 80 132 2150

750 61 091 121 132 80 150 3027

1000 61 111 136 146 80 164 3845

15kV 133 Insulation Level 220 mils Insulation Thickness

10 19 034 092 100 80 118 894

20 19 038 096 104 80 122 1009

30 19 043 100 111 80 129 1181

40 19 048 106 116 80 134 1394

250 37 052 111 122 80 140 1537

350 37 062 121 131 80 149 1936

500 37 074 133 143 80 161 2516

750 61 091 151 161 110 185 3620

1000 61 111 166 180 110 204 4543

25kV 100 Insulation Level 260 mils Insulation Thickness

10 19 034 109 119 80 137 1041

20 19 038 113 123 80 141 1226

30 19 043 118 128 80 146 1380

40 19 048 123 133 80 151 1569

250 37 052 129 139 80 157 1750

350 37 062 138 149 80 167 2163

500 37 074 150 161 110 185 2893

750 61 091 168 183 110 207 3900

1000 61 111 183 197 110 221 4807

35kV 100 Insulation Level 345 mils Insulation Thickness

manufacturing tolerancesDimension and weights shown are nominal unless otherwise indicated and subject to

19

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-94735-05

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

ICEA-S-68-516

SPECIFICATIONS

three conductor cable voltage size andlength

Condumex Mining Cable EPR type SHD-GC

HOW TO ORDER

MINING CABLE EPR TYPE SHD-GC

THREE CONDUCTOR 5000 VOLTS

18SHD-GC01

with a nylon webbing provides a tough defense

round configuration

and Health Administration Approval No P-218-1-MSHA

by the Pennsylvania Department of Environmental

Resources Meets MSHA flame test requirements

6) Acceptance No P-218-1-MSHA by Mines Safety

5) CV-Cured extra-heavy-duty CPE reinforced

4) Prevulcanized thermosetting non-wicking fillers

mechanical resistant jacket

resistance outstanding corona resistance

high dielectric strength and chemical resistance

designed for flexibility and resistance to

FEATURES

2) Ground check conductor facilitates fail-safe

3) EPR insulation offers excellent heat and moisture

are used if necessary to obtain a substantially

1) Special tinned copper stranded conductors

fatigue resulting from bending and flexing

ground monitoring for maximum safety

Dimension and weights shown are nominal unless otherwise indicated and subject to

6 7x3029 020 110 10 8 156

4 7x4729 025 110 8 8 168

2 7x7429 031 110 6 8 187

1 7x3725 035 110 5 8 195

10 7x4725 039 110 4 8 208

20 7x6025 045 110 3 8 220

30 7x7525 050 110 2 8 236

40 19x3525 059 110 1 8 250

300 19x4925 069 120 10 8 281

350 19x5825 076 120 20 8 295

1675

1888

2322

2653

3068

3504

4206

5023

6371

7654

Size Number of Conductor Insulation Ground Ground OverallAWG Strands Diameter Thickness Size Check Size Diameterkcmil AWG inch mils AWG AWG inch

NetWeightlbmft

manufacturing tolerances

MAXIMUM CONDUCTOR TEMPERATURE

Normal continuous 90deg C130deg COverload

250deg CShort circuit

MAXIMUM OPERATING VOLTAGE

5000 volts

Trailing cable on ac mining equipment

where service conditions are severe andmaximum safety is mandatory such as

APPLICATION

power shovels and draglines in open-pit

mines quarries gantry cranes and slag

reclaiming Also used for medium voltage

distribution in underground mines where

frequent relocation is necessary

DESCRIPTION

1) Three flexible annealed tinned copper rope-lay stranded conductors

2) Extruded semi-conducting conductor shieldand ethylene propylene rubber (EPR) insulation

3) Color coded cottoncopper braid shield applied over semi-conducting tape

4) Two annealed tinned copper rope-lay strandedgrounding conductors

5) Annealed tinned copper rope-lay stranded

and covered with a yellow cotton braid

chlorinated polyethylene (CPE) jacket

6) Rubberized cotton binder tape7) Nylon web reinforced extra-heavy-duty

ground check conductor yellow EPR insulation

346 2 157

110

RoHS

5) Overall flame retardant PVC jacket

DESCRIPTION

XLP insulation3) Fillers (if required)

4) Binder tape over core

2) Cross-Linked polyethylene thermosetting

1) Annealed bare stranded compressed

Class B copper conductors

without grounding conductorVolts number and size of conductors with or

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet

lighting control signal and communication circuitsin cable trays raceways direct burial or on

HOW TO ORDER

Condumex Tray Cable Type TCXHHW 600

SPECIFICATIONS

UL-1277 amp UL-44

APPLICATION

most chemicals in accordance with the

MAXIMUM OPERATING VOLTAGE

National Electrical Code

or dry locations and in the presence of oil and

6) Acceptable for Class 1 Division 2 HazardousLocations applications

O5) PVC jacket is UL rated 90 C and listed OilResistant I

600 volts

MAXIMUM CONDUCTOR TEMPERATUREO 90 C

O130 C

FEATURES

OverloadNormal

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

National Electrical Code

BTU flame test)3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

tray cable use in accordance with the

3 145 2

POWER CABLE TYPE TC

XHHW 600 VOLTS

Size Number Ground Insulation Jacket Overall Netof Conductor Thickness Thickness Diameter Weight

AWGkcmilConductors AWG mils mils inch lbMft

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 3 10 45 60 066 310

6 3 8 45 60 074 448

4 3 8 45 80 088 659

2 3 6 45 80 103 968

10 3 6 55 80 121 1428

20 3 4 55 80 131 1735

30 3 4 55 80 142 2150

40 3 4 55 80 154 3620

250 3 4 65 110 175 3190

350 3 3 65 110 196 4305

500 3 2 65 110 225 5940

8 4 10 45 60 073 385

6 4 8 45 80 083 568

4 4 8 45 80 097 832

2 4 6 45 80 112 1230

10 4 6 5 80 134 1825

20 4 4 55 80 145 2212

30 4 4 55 80 157 2751

40 4 4 55 110 177 3462

250 4 4 65 110 198 4097

350 4 3 65 110 217 5542

500 4 2 65 110 249 7690

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

111

7) ldquoERrdquo Listed per UL 1277

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

National Electrical Code References

Product Article 310 Table 310-13

Ampacities Article 310-15

HOW TO ORDER

CONDUMEX type RHH-RHW-USE-2

XLPE 600 volts size length quantity

packaging

DESCRIPTION

polyethylene (XLPE) insualtion

1) Annealed bare stranded class B

conductor

2) Flame-retardant cross-linked

TYPE RHH-RHW-USE-2

COPPER XLPE 600 VOLTS

APPLICATION

May be installed in free air all raceways or

underground service entrance cable

Type RHH 90deg C Dry and

temperatures

6) Stable electrical propoerties

UL-44 Standard for Rubber-Insulated

use in direct burial in industrial andcommercial application May be used as

7) Extremely tough

SPECIFICATIONS

4) Good resistance to most oils and

3) UL approved as VW-1 (RHH or RHW)

chemicals5) Suitable for installation in sub-zero

2) UL listed as types RHH or RHW or USE forresistant insulation

damp locations

ICEA S-66-524 Standard for Cross-Linked

Type RHW or 75deg C Dry and

use in accordance with the National

Electrical Code

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

MAXIMUM OPERATING VOLTAGE

USE wet locatinons

1) Flame retardant moisture and heat

FEATURES

Wires and Cables

Polyethylene Insualted Wire and Cable

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch mils inch lbMft

8 7 165 015 60 027 73

6 7 262 018 60 031 108

4 7 417 022 60 035 161

2 7 663 028 60 041 245

10 19 106 036 80 053 392

20 19 133 041 80 058 485

30 19 168 046 80 063 600

40 19 211 051 80 069 746

250 37 056 95 076 887

300 37 061 95 082 1052

350 37 066 95 087 1216

400 37 071 95 092 1380

500 37 079 95 099 1708

600 61 087 110 111 2055

750 61 097 110 120 2542

1000 61 112 110 136 3353

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

11 112

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

copper conductor

2) Cross-linked polyethylene (XLPE)

insulation

compressed (6 AWG-1000 MCM)

1) Annealed bare stranded class B

concentric round (14-8 AWG)

APPLICATION

Power or control circuits in recognized

switchboard wiring

Dry locations 90deg C

presence of oil Also suitable as

designs

temperatures

4) Suitable for installation in sub-zero

pulling and greater conduit fill

5) Optical For CT use marking for use in

cable trays Sunlight resistant in

FEATURES

2) Good moisture resistance

raceways in wet or dry location and in

90deg CWet locationsOverload 130deg CShort Circuit

MAXIMUM OPERATING VOLTAGE

3) Good resistance to most oils and

chemicals

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

accordance with NEC Article 3186) Available in VW-1 and non VW-1

UL-44

SPECIFICATIONS

Chapter 9

250deg C

1) Smaller overall diameter for easier

HOW TO ORDER

National Electrical Code References

Article 310

VULCANELreg XLPE cable type XHHW-2600 volts size and length

Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL

TYPE XHHW-2 600 VOLTS

reg XLPE CABLE

2 1

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch Mils inch lbMft

manufacturing tolerances

14 7 41 007 30 013 19

12 7 65 009 30 015 48

10 7 103 011 30 017 42

8 7 165 015 45 024 71

6 7 262 018 45 027 98

4 7 417 023 45 032 153

2 7 663 029 45 038 241

10 19 1060 037 55 048 378

20 19 1330 041 55 052 446

30 19 1680 047 55 058 556

40 19 2110 052 55 063 697

250 37 057 65 070 851

300 37 062 65 075 997

350 37 067 65 080 1180

400 37 072 65 085 1306

500 37 080 65 093 1662

600 61 088 80 104 1974

750 61 098 80 115 2450

1000 61 114 80 130 3240

Dimension and weights shown are nominal unless otherwise indicated and subject to

13

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

APPLICATION

FEATURES

MAXIMUM OPERATING VOLTAGE

MAXIMUM CONDUCTOR TEMPERATURE

UL-44

SPECIFICATIONS

Chapter 9

HOW TO ORDER

National Electrical Code References

Article 310Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL S8000

XHHW or XHHW-2 600 VOLTS ALUMINUM

reg XLPE CABLE

manufacturing tolerances

Size Number Insulations Overall Netof Thickness Diameter Weight

AWGkcmilStrands Mils In LbMft

6 7 45 027 42

4 7 45 031 59

2 7 45 036 88

1 7 55 042 111

10 19 55 045 136

20 19 55 049 165

30 19 55 054 203

40 19 55 059 250

250 37 65 066 300

300 37 65 071 354

350 37 65 075 405

500 37 65 087 562

600 61 80 098 684

750 61 80 108 840

900 61 80 117 995

Dimension and weights shown are nominal unless otherwise indicated and subject to

2 13

1) Stranded compact class B AA-8000 series aluminum alloy soft conductor2) Separator tape3) Cross-linked polyethylene (XLPE) insulation type XHHW or XHHW-2

Branch-circuits and feeders conductors in low voltage for buildings schools auditoriums hospitals stadiums museums poultry farms etc Industrial and commercial buildings For use in cable trays or raceways in wet and dry locations

600 volts

Wet and dry continuousOverloadShort circuit

90 C130 C125 C

1) Easier pulling and greater conduit fill2) Good moisture resistance3) Excellent dielectrics properties4) Continuous 90 C operating temperature in wet or dry locations5) Suitable for use in cable trays (10 AWG and greater)6) VW-1 compliant7) Sunlight resistant insulatedRoHS compliant

APPROVALS

Type XHHW or XHHW-2 UL listedType Rw90 or RWU90 upon special request

Vulcanel S8000 cable type XHHW or XHHW-2 RoHS CT-SR with stranded compact class B AA-8000 series aluminum alloy soft conductor size length and product number

reg

114

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANEL EPR ANTILLAMA CABLE

600 VOLTS

26ACSR01

DESCRIPTION

FEATURES

HOW TO ORDER

SPECIFICATIONSSPECIFICATIONS

3 2 1

1) Annealed coated or un-coated stranded class B copper conductor2) Ethylene propylene rubber (EPR) insulation3) Chlorosulfonated polyethylene (Hypalon) or chlorinated polyethylene(CPE) jacket

APPLICATION

Ideally suited for use in Electrical generating stations May be installed in free air all raceways or direct burial

MAXIMUM CONDUCTOR TEMPERATUREDry LocationsDry and Wet LocationsOverloadShort Circuit

90 C75 C130 C250 C

MAXIMUM OPERATING VOLTAGE600 Volts

1) Flame resistant Meets or exceeds requirements of IEEE 383 flame test2) Deformation resistant at high temperatures3) Excellent Flexibility at low temperature suitable for installation in sub-zero temperatures4) Extra tough mechanically rugged composite insulation and jacket construction6) Resistant to most oils and chemicals

ICEA S-95-658

VULCANEL EPR ANTILLAMA cable 600 volts size length National Electrical Code ReferencesAmpacities Article 31318-10Cable Trays Article 318

Dupont trade mark

reg reg

Size Number Conductor Insulation Jacket Overall Netof Diameter Thickness Thickness Diameter Weight

AWGkcmilStrands Inch mils mils inch lbMft

8 7 015 45 15 026 79

6 7 118 45 30 042 125

4 7 023 45 30 038 179

2 7 029 45 30 043 269

10 19 037 55 45 056 432

20 19 041 55 45 061 528

30 19 047 55 45 066 647

40 19 052 55 45 071 797

250 37 057 65 45 082 982

300 37 062 65 65 087 1146

352 37 067 65 65 092 1351

400 37 072 65 65 097 1480

500 37 080 65 65 105 1782

600 61 088 80 65 116 2186

750 61 098 80 65 126 2685

1000 61 114 80 65 141 3410

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

reg reg

15

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

CODE SIZE STRAND OVERALL DIAMETER NET WEIGHT RUPTURE STRENGTH

Turkey 6 61 0198 503 36 54

Swan 4 61 0250 635 58 86

Swallow 3 61 0281 714 73 108

Sparrow 2 61 0316 803 91 136

Robin 1 61 0355 902 115 171

Raven 10 61 0398 1011 145 216

Quail 20 61 0447 1135 183 273

Pigeon 30 61 0502 1275 231 344

Penguin 40 61 0563 1430 291 433

Partridge 2668 267 0642 1631 366 544

Linnet 3364 267 0721 1831 162 688

Oriole 3364 307 0741 1882 525 782

Ibis 3975 267 0783 1989 545 811

Lark 3975 307 0806 2047 619 921

Hawk 4770 267 0858 2179 654 973

Hen 4770 307 0883 2243 743 1106

Heron 5000 307 0904 2296 781 1162

Dove 5565 267 0927 2355 765 1138

Eagle 5565 307 0953 2421 869 1293

Duck 6050 547 0953 2421 779 1159

Grosbeak 6360 267 0990 2515 872 1298

Starling 7155 267 1051 2670 986 1467

Crow 7155 547 1035 2629 918 1366

Drake 7950 267 1108 2814 1095 1629

Condor 7950 547 1093 2776 1021 1520

Canary 9000 547 1162 2951 1160 1726

Rail 9540 457 1165 2959 1076 1601

Bluejay 11130 457 1259 3198 1256 1869

11903

18608

23040

28575

35550

43875

53100

66825

84308

113175

141075

173250

163125

203175

195075

238500

247500

227250

279000

234000

252000

283500

261000

315000

281250

323370

258750

309870

WORD AWG or MCM ALSteel Inch mm Lbsmft kgkm lbs

manufacturing tolerances

Condumex can currently produce a wider

BARE ACSR CABLE

ALUMINUM CONDUCTOR STEEL REINFORCED

26ACSR01

DESCRIPTION

CONDUCTORS

Aluminum 1350 wire concentrically laid overa solid or stranded galvanized steel core

Mechanical design requirements5) Good corrosion resistance

3) High resistance to mechanical strength4) Wide variety of sizes available in long

lengths to suit both electrical and

fewer towers required

strength to permit the longest possiblespans

2) Minimum sag between supports with

1) Ideal combination of conductivity and

FEATURES

Code Word quantity required in weight

ACSR cable size Aluminum Association

HOW TO ORDER

Overhead transmission subtransmission

overhead electrical cables Messenger and

overhead lines Messenger cables to support

APPLICATION

and distribution systems Static wires to protect

power support conductor in catenary systems

for railroad electrification

SPECIFICATIONS

ASTM B498 Galvanized steel class A

ASTM B232 Conductor overall

SPECIFICATIONS

ASTM B230 Aluminum wires

MAXIMUM CONDUCTOR TEMPERATURE

Normal Operation 75 degC

116

Dimension and weights shown are nominal unless otherwise indicated and subject to

range of products then what is listedPlease contact us for other items

Grand Prairie Texas800-925-9473

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
Page 4: 5Power Cable Specs Set 2 - Condumex  · PDF fileCondumex Wire and Cable 2590 114th Street, ... Type Conductors Diameter Ampacity Weight AWG ... 6 19 26.2 0.18 30 6 0.26

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947304-11

HOW TO ORDER

MC Armalat Vinilat Nylon Cable TypeTHHNTHWN gauge and length

DESCRIPTION

identification Types THHN-THWN

1) Soft annealed wire or stranded class C

copper conductor

2) PVC insulationNylon jacket with color

APPLICATION

Dry Locations (THHN Type) 90deg C

High resistance to heat and moisture

Good resistance to gasoline and oil

UL-1569

Flame retardance

SPECIFICATIONS

impact and abrasion3)The armor makes the cable resistant to

4) Type THHNTHWN offers

2) Aluminum interlock armor provides greatinstallations

Metal Clad Cable

Wet Locations (THWN Type) 75deg C

Flexibility

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

MAXIMUM OPERATING VOLTAGE

1) Easy installation on exposed or concealed

FEATURES

14 Solid 2 0242rdquo 0414rdquo 25 97

14 Solid 3 0269rdquo 0442rdquo 25 117

14 Solid 4 0302rdquo 0475rdquo 25 137

12 Solid 2 0277rdquo 0450rdquo 30 126

12 Solid 3 0309rdquo 0482rdquo 30 154

12 Solid 4 0347rdquo 0520rdquo 30 183

10 Solid 2 0346rdquo 0519rdquo 40 178

10 Solid 3 0386rdquo 0559rdquo 40 221

10 Solid 4 0434rdquo 0606rdquo 40 266

8 Stranded 2 0492rdquo 0664rdquo 55 259

8 Stranded 3 0549rdquo 0721rdquo 55 332

8 Stranded 4 0617rdquo 0789rdquo 55 406

6 Stranded 2 0568rdquo 0741rdquo 75 361

6 Stranded 3 0634rdquo 0807rdquo 75 468

6 Stranded 4 0713rdquo 0885rdquo 75 577

Dimension and weights shown are nominal unless otherwise indicated and subject to

Size Number of Nominal Nominal Allowable NetType Conductors Diameter Diameter Ampacity Weight

AWGUnder Armor Over ArmorAWG 90 C lbMft

manufacturing tolerances

11

3) Insulated grounded conductor

4) Plastic binder tape

5) Interlocked aluminum armor

Branch feeder and service power distributionsin industrial commercial and residential buildings For power lighting control and signal circuits in generalApplications where maximum security is required as hazardous locations Class I Div 2 Class II Div 2 and Class III Div I

UL-1581

File E 115900

TM TM

TYPE MC Metal Clad Cables

THHNTHWN 600V ArmalatTM

5) Insulated ground (green) is same construction as conductors

2 Conductor black white

3 Conductor black white red

4) Conductor color code

4 Conductor black white red blue

Type MC Cable meets or excides all applicable ASTM Specifications UL standards for safety

UL-83

Armored Cable

11

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947311-10

THHN or THWN-2 600 VOLTS (MTW STRANDED)

DESCRIPTION

2) Polyvinyl chloride (PVC insulation)3) Nylon overall protective jacket

123

Dimension and weights shown are nominal unless otherwise indicated and subject to

14 1 Solid 41 006 15 5 010

12 1 Solid 65 008 15 5 012

10 1 Solid 103 010 20 5 015

14 19 41 007 15 5 012

12 19 65 009 15 5 014

10 19 103 011 20 5 017

8 19 165 015 30 5 023

6 19 262 018 30 6 026

4 19 417 023 40 6 034

3 19 526 026 40 7 036

2 19 663 029 40 7 039

1 19 837 032 50 7 045

10 19 106 037 50 8 050

20 19 133 041 50 8 054

30 19 168 047 50 8 059

40 19 211 052 50 8 065

250 37 057 60 9 072

300 37 062 60 9 078

350 37 067 60 9 083

400 37 072 60 9 087

500 37 080 60 9 096

600 61 088 70 10 106

750 61 098 70 10 115

1000 61 114 70 10 127

16

23

37

17

26

40

65

99

157

197

241

306

380

472

587

729

870

1033

1196

1359

1685

2023

2454

3347

Size Number Conductor Conductor Insulation Jacket OverallAWG of Area Diameter Thickness Thickness Diameterkcmil Strands kcmil mils mils mils inch

NetWeightlbmft

manufacturing tolerances

VINILAT Nylon solid or stranded typereg

General use in commercial and industrial

SPECIFICATIONS

construction and installations whereresistance against oils and gasoline is

APPLICATION

75deg CIn oil (Oil resistant II)

6) Superior abrasion and mechanical properties7) Sizes 10 and larger are marked For CT use and are approved for installation

overload exists

in cable trays Sunlight resistant in Accordance with NEC Article 318

manufacturing process4) Flame retardant UL listed as VW-15) Smooth nylon jacket aids in easier pulling

1) Good resistance to moisture heat oil gasoline chemicals and grease2) Suitable for installation where thermal

3) Strict quality control during

FEATURES

MAXIMUM CONDUCTOR TEMPERATURE

Dry locations (THHN)Dry and wet locations (THWN-2)

90deg C90deg C

MAXIMUM OPERATING VOLTAGE

600 volts

required May be used for power and

gases gasoline and chemicals Alsosuitable as machine tool and switchboard

control circuits in recognized raceways inwet or dry locations and in presence of

wiring

UL-83

HOW TO ORDER

NATIONAL ELECTRICAL CODE REFERENCE

Ampacities

Switchboard wiring

Conduit fill tables

Article 3 10-15

Article 384

Chapter 9

THHN or THWN-2 600 volts size color and length

12

RoHS

IEEE 1202 and ULFT4 Flame Test

CESMEC E-022-01-5505

Type THHN or THWN-2 Annealed bare solid (14-10 AWG) type THHN or THWN-2 Annealed bare stranded class C concentric round (14-2 AWG) compressed stranding class B (1 AWG-1000MCM)copper conductor

1)

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947311-10

XHHW-2 600 VOLTS

POWER CABLE TYPE TC

DESCRIPTION

Dimension and weights shown are nominal unless otherwise indicated and subject to

Size Number Number Jacket Overall Netof of Thickness Diameter WeightAWG

Strands Conductors mils inches lbMft

2 45 033 65

3 45 035 81

4 45 038 103

14 7 5 45 042 125

7 60 049 182

9 60 060 230

12 60 067 288

19 80 077 455

2 45 041 84

3 45 043 112

4 45 047 140

5 45 051 172

12 7 7 60 063 247

9 60 073 310

12 60 081 397

19 80 098 626

2 45 046 97

3 45 048 125

4 60 057 173

10 7 5 60 062 209

7 60 071 279

9 60 081 350

12 80 095 481

manufacturing tolerances

FEATURES

Wet or DryDry

90deg C90deg C

APPLICATION

Electrical Code

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet ordry locations and in the presence of oil and most

lighting control signal and communcation circuitsin raceways direct burial in earth or in

SPECIFICATIONS

S-73-532 (table E-2 or Method SB 4)7) Circuit identification color coded per ICEA

UL 1277 UL 44

HOW TO ORDER

chemicals in accordance with the National

MAXIMUM OPERATING VOLTAGE

600 volts

MAXIMUM CONDUCTOR TEMPERATURE

Condumex Tray Cable Type TCXHHW-2

600 volts number and size of conductors

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

BTU flame test3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

Electrical Code

tray cable used in accordance with the National

Resistant I

O5) PVC jacket is UL rated 90 C and listed Oil

Location Applications6) Acceptable for Class I Division 2 Hazardous

7a) Other color coding methods are available based on ICEA S-73-532

24 13

1) Annealed bare Class C concentric strand copper conductors2) Flame retardant XLPE3) Binder tape over core4) Overall flame retardant PVC jacket

Contact factory for items not shown above

8) ldquoERrdquo Listed per UL 1277

1113

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947311-10

THHNTHWN 600 VOLTS

POWER CABLE TYPE TC

DESCRIPTION

2) Polyvinyl Chloride (PVC) thermoplastic

insulation

1) Annealed bare Class C concentric

strand copper conductors

3) Nylon protective covering

4) Binder tape over core

5) Overall flame retardant PVC jacket

Dimension and weights shown are nominal unless otherwise indicated and subject to

Size Number Number Jacket Overall Netof of Thickness Diameter WeightAWG

Strands Conductors mils inches lbMft

2 45 034 68

3 45 036 87

4 45 040 109

14 19 5 45 043 130

7 45 046 167

9 60 056 234

12 60 063 285

16 60 067 335

2 45 038 90

3 45 040 119

4 45 043 154

5 45 046 173

12 19 7 60 055 247

9 60 064 326

12 60 071 400

16 60 076 485

2 45 045 139

3 45 047 180

4 60 055 247

10 19 5 60 060 178

7 60 065 367

9 60 075 480

12 80 089 637

manufacturing tolerances

FEATURES

Wet or DryDry

75deg C90deg C

APPLICATION

Electrical Code

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet ordry locations and in the presence of oil and most

lighting control signal and communcation circuitsin raceways direct burial in earth or in

SPECIFICATIONS

S-73-532 (table E-2 or Method SB 4)7) Circuit identification color coded per ICEA

UL 1277 UL 83 and ER Approved

HOW TO ORDER

chemicals in accordance with the National

MAXIMUM OPERATING VOLTAGE

600 volts

MAXIMUM CONDUCTOR TEMPERATURE

Condumex Tray Cable Type TCTHHN

600 volts number and size of conductors

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

BTU flame test3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

Electrical Code

tray cable used in accordance with the National

Resistant I

O5) PVC jacket is UL rated 90 C and listed Oil

required metallic sheathed cablessubstantial cost savings over the previouslyLocation Applications Type TX offers

6) Acceptable for Class I Division 2 Hazardous

7a) Other color coding methods are available based on ICEA S-73-532

4

245 13

8) ldquoERrdquo Listed per UL 1277

RoHS

5) Binder tape over core

750 kcmil) copper conductors

6) Overall flame retardant PVC jacket

DESCRIPTION

3) Nylon protective covering4) Fillers

1) Annealed bare Class C (8-2 AWG)compressed stranded Class B (10 AWG-

2) Polyvinyl Chloride thermoplastic insulation

36 145 2

POWER CABLE TYPE TC

THHNTHWN 600 VOLTS

Size Number Ground Insulation Jacket Overall Netof Conductor Thickness Thickness Diameter Weight

AWGkcmilConductors AWG mils mils inch lbMft

8 3 10 305 60 0638 338

6 3 8 305 60 0698 448

4 3 6 407 80 0884 693

2 3 6 407 80 1015 1012

1 3 8 507 80 1150 1210

10 3 6 508 80 1223 1495

20 3 6 508 80 1320 1858

30 3 4 508 80 1428 2297

40 3 4 508 80 1549 2791

250 3 4 609 80 1760 3374

350 3 3 609 110 1980 4526

500 3 2 609 110 2260 6230

750 3 1 7010 110 2967 8845

10 4 6 508 80 1350 1913

20 4 6 508 80 1457 2311

40 4 4 508 110 1773 3597

350 4 3 609 110 2188 5754

500 4 2 609 110 2502 8018

750 4 1 7010 140 3057 11716

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

MAXIMUM OPERATING VOLTAGE

UL 1277 UL 83 and ER Approved

7) Circuit identification color coded per ICEA

MAXIMUM CONDUCTOR TEMPERATURE

Wet or DryDry

75deg C90deg C

required metallic sheathed cables

3) Sunlight resistant can be installed outdoors

tray cable use in accordance with the National

Electrical Code

APPLICATION

in accordance with the National Electrical Code

6) Acceptable for Class I Division 2 Hazardous

4) UL listed as Type TC for power and control

600 volts

5) PVC jacket is UL rated 90deg C and listed Oil

Resistant I

1) UL listed for direct burial

2) Flame retardant (passes UL 1277 70000

BTU flame test)

FEATURES

Condumex Type TC cable may be used for

cable may be used in wet or dry locations and in the presence of oil and most chemicals

power lighting control signal and communication circuits in raceways direct

HOW TO ORDER

600 volts number and size of conductorsCondumex Tray Cable Type TCTHHN

SPECIFICATIONS

S-73-532 (table E-2 or Method SB 4)

Location Applications Type TC offers

substantial cost savings over the previously

7a) Other color coding methods are available based on ICEA S-73-532

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947303-06

5

8) ldquoERrdquo Listed per UL 1277

RoHS

1) Annealed bare stranded class B compact

copper conductor

DESCRIPTION

3) Ethylene propylene (EPR) or cross-linked

polyethylene (XLPE) insulation

4) Polyvinyl chloride (PVC) protective jacket

2) Extruded semiconducting strand shield

VULCANELreg MEDIUM VOLTAGE

WET OR DRY POWER CABLE 5 KVXLPE OR EPR NON-SHIELDED

24 13

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

Size Number Conductor Insulation Insulation Jacket OverallAWG of Diameter Thickness Diameter Thickness Diameterkcmil Strands inch inch inch mils Inch XLPE EPR

Net WeightLbMft

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

manufacturing tolerances

5kV 133 Insulation Level 115 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject to

cable voltage and insulation level conductor

Ampacities

Cable Trays

Type MV

ICEA S-66-524 AEIC CS-S (XLP)

extrusion) results in a virtually perfect cable core

- Very low dielectric loss

Normal Operation 105deg C130deg CEmergency Overload

VULCANELreg 5kv Non-shielded power cables

adequate for proper termination of the shielding

1) Simultaneous extrusion of strand shield

250deg CShort Circuit

UL 1072

326

318

310-15

National Electrical Code References

VULCANELreg EPRXLPE Non-Shielded power

size and type length and reel dimensions

SPECIFICATIONS

are ideally suited for use in industrial andutility applications where shields cannot be

APPLICATION

abrasion ozone and moisture

- Electrical stability under stress- Low dielectric loss- Chemical resistance

FEATURES

3) Easy-stripping insulation shield4) The external PVC jacket is resistant to

EPR insulation offers- Excellent heat moisture and corona

2) XLPE insulation offers- Low moisture absorption- Good resistance to chemicals

insulation and insulation shield (triple

accordance with the National ElectricalCode

5) UL listed as MV-105 sunlight resistantdirect burial Optional marking For CTuse available on single conductor in

HOW TO ORDER

resistance

MAXIMUM CONDUCTOR TEMPERATURE

Page 1 of 2

ICEA S-68-516 AEIC CS-6-87 (EPR)

6

RoHS

VULCANELreg MEDIUM VOLTAGE

WET OR DRY POWER CABLE 5 KVXLPE OR EPR NON-SHIELDED

Page 2 of 2

Size Number Conductor Insulation Insulation Jacket OverallAWG of Diameter Thickness Diameter Thickness Diameterkcmil Strands inch inch inch mils Inch XLPE EPR

Net WeightlbMft

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

25kV 100 Insulation Level 260 mils Insulation Thickness

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

35kV 100 Insulation Level 345 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

15kV 133 Insulation Level 220 mils Insulation Thickness

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

17

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANELreg MEDIUM VOLTAGE EPR

SHIELDED POWER CABLES 5 15 25 35 KV

346 125

DESCRIPTION

1) Annealed bare stranded class B compactcopper conductor

2) Extruded semiconducting strand shield3) Ethylene propylene rubber (EPR) insulation4) Extruded semiconducting insulation shield5) Annealed copper tape shield (25 overlap

6) Polyvinyl chloride (PVC) protective jacketminimum)

Three-phase electrical distribution systems

trays

Suitable for use in overhead installationsrecognized raceways direct burial or cable

APPLICATION

voltage and insulation level conductor

AmpacitiesCable TraysType MV

- Chemical resistance

5) The external PVC jacket is resistant to

- Electrical stability under stress

MAXIMUM CONDUCTOR TEMPERATURE

SPECIFICATIONS

use available on single conductor in

accordance with the National ElectricalCode

abrasion ozone and moisture6) UL listed as MV-105 sunlight resistant

direct burial Optional marking For CT

3) Easy-stripping insulation shield4) Tape shield provides high short circuit

capabilities and uniform shield impedance

- Low dielectric loss

UL 1072

size and type length and reel dimensions

ICEA S-68-516 AEIC CS6-87

326318310-15

National Electrical Code References

VULCANELreg EPR shielded power cable

2) EPR insulation offers- Excellent heat moisture and corona

resistance

insulation and insulation shield (tripleextrusion) results in a virtually perfect

cable core

250 degCShort Circuit

1) Simultaneous extrusion of strand shield

Normal Operation 105 degC130 degCEmergency Overload

FEATURES

SPECIFICATIONS

HOW TO ORDER

Page 1 of 2

Size Number Conductor Insulation Insul Shld Jacket Overall Netof Diameter Thickness Diameter Thickness Diameter Weight

AWGkcmilStrands Inch inch inch mils Inch lbMft

6 7 017 045 053 60 067 290

4 7 022 049 057 60 071 357

2 7 027 055 063 60 074 478

10 19 034 062 070 80 085 668

20 19 038 066 074 80 092 775

30 19 043 071 079 80 097 933

40 19 048 076 084 80 102 1071

250 37 052 081 090 80 107 1226

350 37 062 091 099 80 117 1560

500 37 074 103 113 80 132 2150

750 61 091 121 132 80 150 3027

1000 61 111 136 146 80 164 3845

5kV 133 Insulation Level 115 mils Insulation Thickness

2 7 027 067 075 80 093 570

10 19 034 074 082 80 100 736

20 19 038 078 086 80 104 849

30 19 043 083 091 80 109 1010

40 19 048 088 096 80 114 1190

250 37 052 094 102 80 120 1330

350 37 062 103 114 80 132 1753

500 37 074 116 126 80 144 2280

750 61 091 134 144 80 162 3142

1000 61 111 136 159 110 183 5794

5kV 100 Insulation Level 175 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

Page 2 of 2

VULCANELreg MEDIUM VOLTAGE EPR

SHIELDED POWER CABLES 5 15 25 35 KV

Size Number Conductor Insulation Insul Shld Jacket Overall Netof Diameter Thickness Diameter Thickness Diameter Weight

AWGkcmilStrands Inch inch inch mils Inch lbMft

6 7 017 045 053 60 067 290

4 7 022 049 057 60 071 357

2 7 027 055 063 60 074 478

10 19 034 062 070 80 085 668

20 19 038 066 074 80 092 775

30 19 043 071 079 80 097 933

40 19 048 076 084 80 102 1071

250 37 052 081 090 80 107 1226

350 37 062 091 099 80 117 1560

500 37 074 103 113 80 132 2150

750 61 091 121 132 80 150 3027

1000 61 111 136 146 80 164 3845

15kV 133 Insulation Level 220 mils Insulation Thickness

10 19 034 092 100 80 118 894

20 19 038 096 104 80 122 1009

30 19 043 100 111 80 129 1181

40 19 048 106 116 80 134 1394

250 37 052 111 122 80 140 1537

350 37 062 121 131 80 149 1936

500 37 074 133 143 80 161 2516

750 61 091 151 161 110 185 3620

1000 61 111 166 180 110 204 4543

25kV 100 Insulation Level 260 mils Insulation Thickness

10 19 034 109 119 80 137 1041

20 19 038 113 123 80 141 1226

30 19 043 118 128 80 146 1380

40 19 048 123 133 80 151 1569

250 37 052 129 139 80 157 1750

350 37 062 138 149 80 167 2163

500 37 074 150 161 110 185 2893

750 61 091 168 183 110 207 3900

1000 61 111 183 197 110 221 4807

35kV 100 Insulation Level 345 mils Insulation Thickness

manufacturing tolerancesDimension and weights shown are nominal unless otherwise indicated and subject to

19

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-94735-05

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

ICEA-S-68-516

SPECIFICATIONS

three conductor cable voltage size andlength

Condumex Mining Cable EPR type SHD-GC

HOW TO ORDER

MINING CABLE EPR TYPE SHD-GC

THREE CONDUCTOR 5000 VOLTS

18SHD-GC01

with a nylon webbing provides a tough defense

round configuration

and Health Administration Approval No P-218-1-MSHA

by the Pennsylvania Department of Environmental

Resources Meets MSHA flame test requirements

6) Acceptance No P-218-1-MSHA by Mines Safety

5) CV-Cured extra-heavy-duty CPE reinforced

4) Prevulcanized thermosetting non-wicking fillers

mechanical resistant jacket

resistance outstanding corona resistance

high dielectric strength and chemical resistance

designed for flexibility and resistance to

FEATURES

2) Ground check conductor facilitates fail-safe

3) EPR insulation offers excellent heat and moisture

are used if necessary to obtain a substantially

1) Special tinned copper stranded conductors

fatigue resulting from bending and flexing

ground monitoring for maximum safety

Dimension and weights shown are nominal unless otherwise indicated and subject to

6 7x3029 020 110 10 8 156

4 7x4729 025 110 8 8 168

2 7x7429 031 110 6 8 187

1 7x3725 035 110 5 8 195

10 7x4725 039 110 4 8 208

20 7x6025 045 110 3 8 220

30 7x7525 050 110 2 8 236

40 19x3525 059 110 1 8 250

300 19x4925 069 120 10 8 281

350 19x5825 076 120 20 8 295

1675

1888

2322

2653

3068

3504

4206

5023

6371

7654

Size Number of Conductor Insulation Ground Ground OverallAWG Strands Diameter Thickness Size Check Size Diameterkcmil AWG inch mils AWG AWG inch

NetWeightlbmft

manufacturing tolerances

MAXIMUM CONDUCTOR TEMPERATURE

Normal continuous 90deg C130deg COverload

250deg CShort circuit

MAXIMUM OPERATING VOLTAGE

5000 volts

Trailing cable on ac mining equipment

where service conditions are severe andmaximum safety is mandatory such as

APPLICATION

power shovels and draglines in open-pit

mines quarries gantry cranes and slag

reclaiming Also used for medium voltage

distribution in underground mines where

frequent relocation is necessary

DESCRIPTION

1) Three flexible annealed tinned copper rope-lay stranded conductors

2) Extruded semi-conducting conductor shieldand ethylene propylene rubber (EPR) insulation

3) Color coded cottoncopper braid shield applied over semi-conducting tape

4) Two annealed tinned copper rope-lay strandedgrounding conductors

5) Annealed tinned copper rope-lay stranded

and covered with a yellow cotton braid

chlorinated polyethylene (CPE) jacket

6) Rubberized cotton binder tape7) Nylon web reinforced extra-heavy-duty

ground check conductor yellow EPR insulation

346 2 157

110

RoHS

5) Overall flame retardant PVC jacket

DESCRIPTION

XLP insulation3) Fillers (if required)

4) Binder tape over core

2) Cross-Linked polyethylene thermosetting

1) Annealed bare stranded compressed

Class B copper conductors

without grounding conductorVolts number and size of conductors with or

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet

lighting control signal and communication circuitsin cable trays raceways direct burial or on

HOW TO ORDER

Condumex Tray Cable Type TCXHHW 600

SPECIFICATIONS

UL-1277 amp UL-44

APPLICATION

most chemicals in accordance with the

MAXIMUM OPERATING VOLTAGE

National Electrical Code

or dry locations and in the presence of oil and

6) Acceptable for Class 1 Division 2 HazardousLocations applications

O5) PVC jacket is UL rated 90 C and listed OilResistant I

600 volts

MAXIMUM CONDUCTOR TEMPERATUREO 90 C

O130 C

FEATURES

OverloadNormal

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

National Electrical Code

BTU flame test)3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

tray cable use in accordance with the

3 145 2

POWER CABLE TYPE TC

XHHW 600 VOLTS

Size Number Ground Insulation Jacket Overall Netof Conductor Thickness Thickness Diameter Weight

AWGkcmilConductors AWG mils mils inch lbMft

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 3 10 45 60 066 310

6 3 8 45 60 074 448

4 3 8 45 80 088 659

2 3 6 45 80 103 968

10 3 6 55 80 121 1428

20 3 4 55 80 131 1735

30 3 4 55 80 142 2150

40 3 4 55 80 154 3620

250 3 4 65 110 175 3190

350 3 3 65 110 196 4305

500 3 2 65 110 225 5940

8 4 10 45 60 073 385

6 4 8 45 80 083 568

4 4 8 45 80 097 832

2 4 6 45 80 112 1230

10 4 6 5 80 134 1825

20 4 4 55 80 145 2212

30 4 4 55 80 157 2751

40 4 4 55 110 177 3462

250 4 4 65 110 198 4097

350 4 3 65 110 217 5542

500 4 2 65 110 249 7690

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

111

7) ldquoERrdquo Listed per UL 1277

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

National Electrical Code References

Product Article 310 Table 310-13

Ampacities Article 310-15

HOW TO ORDER

CONDUMEX type RHH-RHW-USE-2

XLPE 600 volts size length quantity

packaging

DESCRIPTION

polyethylene (XLPE) insualtion

1) Annealed bare stranded class B

conductor

2) Flame-retardant cross-linked

TYPE RHH-RHW-USE-2

COPPER XLPE 600 VOLTS

APPLICATION

May be installed in free air all raceways or

underground service entrance cable

Type RHH 90deg C Dry and

temperatures

6) Stable electrical propoerties

UL-44 Standard for Rubber-Insulated

use in direct burial in industrial andcommercial application May be used as

7) Extremely tough

SPECIFICATIONS

4) Good resistance to most oils and

3) UL approved as VW-1 (RHH or RHW)

chemicals5) Suitable for installation in sub-zero

2) UL listed as types RHH or RHW or USE forresistant insulation

damp locations

ICEA S-66-524 Standard for Cross-Linked

Type RHW or 75deg C Dry and

use in accordance with the National

Electrical Code

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

MAXIMUM OPERATING VOLTAGE

USE wet locatinons

1) Flame retardant moisture and heat

FEATURES

Wires and Cables

Polyethylene Insualted Wire and Cable

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch mils inch lbMft

8 7 165 015 60 027 73

6 7 262 018 60 031 108

4 7 417 022 60 035 161

2 7 663 028 60 041 245

10 19 106 036 80 053 392

20 19 133 041 80 058 485

30 19 168 046 80 063 600

40 19 211 051 80 069 746

250 37 056 95 076 887

300 37 061 95 082 1052

350 37 066 95 087 1216

400 37 071 95 092 1380

500 37 079 95 099 1708

600 61 087 110 111 2055

750 61 097 110 120 2542

1000 61 112 110 136 3353

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

11 112

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

copper conductor

2) Cross-linked polyethylene (XLPE)

insulation

compressed (6 AWG-1000 MCM)

1) Annealed bare stranded class B

concentric round (14-8 AWG)

APPLICATION

Power or control circuits in recognized

switchboard wiring

Dry locations 90deg C

presence of oil Also suitable as

designs

temperatures

4) Suitable for installation in sub-zero

pulling and greater conduit fill

5) Optical For CT use marking for use in

cable trays Sunlight resistant in

FEATURES

2) Good moisture resistance

raceways in wet or dry location and in

90deg CWet locationsOverload 130deg CShort Circuit

MAXIMUM OPERATING VOLTAGE

3) Good resistance to most oils and

chemicals

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

accordance with NEC Article 3186) Available in VW-1 and non VW-1

UL-44

SPECIFICATIONS

Chapter 9

250deg C

1) Smaller overall diameter for easier

HOW TO ORDER

National Electrical Code References

Article 310

VULCANELreg XLPE cable type XHHW-2600 volts size and length

Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL

TYPE XHHW-2 600 VOLTS

reg XLPE CABLE

2 1

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch Mils inch lbMft

manufacturing tolerances

14 7 41 007 30 013 19

12 7 65 009 30 015 48

10 7 103 011 30 017 42

8 7 165 015 45 024 71

6 7 262 018 45 027 98

4 7 417 023 45 032 153

2 7 663 029 45 038 241

10 19 1060 037 55 048 378

20 19 1330 041 55 052 446

30 19 1680 047 55 058 556

40 19 2110 052 55 063 697

250 37 057 65 070 851

300 37 062 65 075 997

350 37 067 65 080 1180

400 37 072 65 085 1306

500 37 080 65 093 1662

600 61 088 80 104 1974

750 61 098 80 115 2450

1000 61 114 80 130 3240

Dimension and weights shown are nominal unless otherwise indicated and subject to

13

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

APPLICATION

FEATURES

MAXIMUM OPERATING VOLTAGE

MAXIMUM CONDUCTOR TEMPERATURE

UL-44

SPECIFICATIONS

Chapter 9

HOW TO ORDER

National Electrical Code References

Article 310Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL S8000

XHHW or XHHW-2 600 VOLTS ALUMINUM

reg XLPE CABLE

manufacturing tolerances

Size Number Insulations Overall Netof Thickness Diameter Weight

AWGkcmilStrands Mils In LbMft

6 7 45 027 42

4 7 45 031 59

2 7 45 036 88

1 7 55 042 111

10 19 55 045 136

20 19 55 049 165

30 19 55 054 203

40 19 55 059 250

250 37 65 066 300

300 37 65 071 354

350 37 65 075 405

500 37 65 087 562

600 61 80 098 684

750 61 80 108 840

900 61 80 117 995

Dimension and weights shown are nominal unless otherwise indicated and subject to

2 13

1) Stranded compact class B AA-8000 series aluminum alloy soft conductor2) Separator tape3) Cross-linked polyethylene (XLPE) insulation type XHHW or XHHW-2

Branch-circuits and feeders conductors in low voltage for buildings schools auditoriums hospitals stadiums museums poultry farms etc Industrial and commercial buildings For use in cable trays or raceways in wet and dry locations

600 volts

Wet and dry continuousOverloadShort circuit

90 C130 C125 C

1) Easier pulling and greater conduit fill2) Good moisture resistance3) Excellent dielectrics properties4) Continuous 90 C operating temperature in wet or dry locations5) Suitable for use in cable trays (10 AWG and greater)6) VW-1 compliant7) Sunlight resistant insulatedRoHS compliant

APPROVALS

Type XHHW or XHHW-2 UL listedType Rw90 or RWU90 upon special request

Vulcanel S8000 cable type XHHW or XHHW-2 RoHS CT-SR with stranded compact class B AA-8000 series aluminum alloy soft conductor size length and product number

reg

114

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANEL EPR ANTILLAMA CABLE

600 VOLTS

26ACSR01

DESCRIPTION

FEATURES

HOW TO ORDER

SPECIFICATIONSSPECIFICATIONS

3 2 1

1) Annealed coated or un-coated stranded class B copper conductor2) Ethylene propylene rubber (EPR) insulation3) Chlorosulfonated polyethylene (Hypalon) or chlorinated polyethylene(CPE) jacket

APPLICATION

Ideally suited for use in Electrical generating stations May be installed in free air all raceways or direct burial

MAXIMUM CONDUCTOR TEMPERATUREDry LocationsDry and Wet LocationsOverloadShort Circuit

90 C75 C130 C250 C

MAXIMUM OPERATING VOLTAGE600 Volts

1) Flame resistant Meets or exceeds requirements of IEEE 383 flame test2) Deformation resistant at high temperatures3) Excellent Flexibility at low temperature suitable for installation in sub-zero temperatures4) Extra tough mechanically rugged composite insulation and jacket construction6) Resistant to most oils and chemicals

ICEA S-95-658

VULCANEL EPR ANTILLAMA cable 600 volts size length National Electrical Code ReferencesAmpacities Article 31318-10Cable Trays Article 318

Dupont trade mark

reg reg

Size Number Conductor Insulation Jacket Overall Netof Diameter Thickness Thickness Diameter Weight

AWGkcmilStrands Inch mils mils inch lbMft

8 7 015 45 15 026 79

6 7 118 45 30 042 125

4 7 023 45 30 038 179

2 7 029 45 30 043 269

10 19 037 55 45 056 432

20 19 041 55 45 061 528

30 19 047 55 45 066 647

40 19 052 55 45 071 797

250 37 057 65 45 082 982

300 37 062 65 65 087 1146

352 37 067 65 65 092 1351

400 37 072 65 65 097 1480

500 37 080 65 65 105 1782

600 61 088 80 65 116 2186

750 61 098 80 65 126 2685

1000 61 114 80 65 141 3410

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

reg reg

15

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

CODE SIZE STRAND OVERALL DIAMETER NET WEIGHT RUPTURE STRENGTH

Turkey 6 61 0198 503 36 54

Swan 4 61 0250 635 58 86

Swallow 3 61 0281 714 73 108

Sparrow 2 61 0316 803 91 136

Robin 1 61 0355 902 115 171

Raven 10 61 0398 1011 145 216

Quail 20 61 0447 1135 183 273

Pigeon 30 61 0502 1275 231 344

Penguin 40 61 0563 1430 291 433

Partridge 2668 267 0642 1631 366 544

Linnet 3364 267 0721 1831 162 688

Oriole 3364 307 0741 1882 525 782

Ibis 3975 267 0783 1989 545 811

Lark 3975 307 0806 2047 619 921

Hawk 4770 267 0858 2179 654 973

Hen 4770 307 0883 2243 743 1106

Heron 5000 307 0904 2296 781 1162

Dove 5565 267 0927 2355 765 1138

Eagle 5565 307 0953 2421 869 1293

Duck 6050 547 0953 2421 779 1159

Grosbeak 6360 267 0990 2515 872 1298

Starling 7155 267 1051 2670 986 1467

Crow 7155 547 1035 2629 918 1366

Drake 7950 267 1108 2814 1095 1629

Condor 7950 547 1093 2776 1021 1520

Canary 9000 547 1162 2951 1160 1726

Rail 9540 457 1165 2959 1076 1601

Bluejay 11130 457 1259 3198 1256 1869

11903

18608

23040

28575

35550

43875

53100

66825

84308

113175

141075

173250

163125

203175

195075

238500

247500

227250

279000

234000

252000

283500

261000

315000

281250

323370

258750

309870

WORD AWG or MCM ALSteel Inch mm Lbsmft kgkm lbs

manufacturing tolerances

Condumex can currently produce a wider

BARE ACSR CABLE

ALUMINUM CONDUCTOR STEEL REINFORCED

26ACSR01

DESCRIPTION

CONDUCTORS

Aluminum 1350 wire concentrically laid overa solid or stranded galvanized steel core

Mechanical design requirements5) Good corrosion resistance

3) High resistance to mechanical strength4) Wide variety of sizes available in long

lengths to suit both electrical and

fewer towers required

strength to permit the longest possiblespans

2) Minimum sag between supports with

1) Ideal combination of conductivity and

FEATURES

Code Word quantity required in weight

ACSR cable size Aluminum Association

HOW TO ORDER

Overhead transmission subtransmission

overhead electrical cables Messenger and

overhead lines Messenger cables to support

APPLICATION

and distribution systems Static wires to protect

power support conductor in catenary systems

for railroad electrification

SPECIFICATIONS

ASTM B498 Galvanized steel class A

ASTM B232 Conductor overall

SPECIFICATIONS

ASTM B230 Aluminum wires

MAXIMUM CONDUCTOR TEMPERATURE

Normal Operation 75 degC

116

Dimension and weights shown are nominal unless otherwise indicated and subject to

range of products then what is listedPlease contact us for other items

Grand Prairie Texas800-925-9473

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
Page 5: 5Power Cable Specs Set 2 - Condumex  · PDF fileCondumex Wire and Cable 2590 114th Street, ... Type Conductors Diameter Ampacity Weight AWG ... 6 19 26.2 0.18 30 6 0.26

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947311-10

THHN or THWN-2 600 VOLTS (MTW STRANDED)

DESCRIPTION

2) Polyvinyl chloride (PVC insulation)3) Nylon overall protective jacket

123

Dimension and weights shown are nominal unless otherwise indicated and subject to

14 1 Solid 41 006 15 5 010

12 1 Solid 65 008 15 5 012

10 1 Solid 103 010 20 5 015

14 19 41 007 15 5 012

12 19 65 009 15 5 014

10 19 103 011 20 5 017

8 19 165 015 30 5 023

6 19 262 018 30 6 026

4 19 417 023 40 6 034

3 19 526 026 40 7 036

2 19 663 029 40 7 039

1 19 837 032 50 7 045

10 19 106 037 50 8 050

20 19 133 041 50 8 054

30 19 168 047 50 8 059

40 19 211 052 50 8 065

250 37 057 60 9 072

300 37 062 60 9 078

350 37 067 60 9 083

400 37 072 60 9 087

500 37 080 60 9 096

600 61 088 70 10 106

750 61 098 70 10 115

1000 61 114 70 10 127

16

23

37

17

26

40

65

99

157

197

241

306

380

472

587

729

870

1033

1196

1359

1685

2023

2454

3347

Size Number Conductor Conductor Insulation Jacket OverallAWG of Area Diameter Thickness Thickness Diameterkcmil Strands kcmil mils mils mils inch

NetWeightlbmft

manufacturing tolerances

VINILAT Nylon solid or stranded typereg

General use in commercial and industrial

SPECIFICATIONS

construction and installations whereresistance against oils and gasoline is

APPLICATION

75deg CIn oil (Oil resistant II)

6) Superior abrasion and mechanical properties7) Sizes 10 and larger are marked For CT use and are approved for installation

overload exists

in cable trays Sunlight resistant in Accordance with NEC Article 318

manufacturing process4) Flame retardant UL listed as VW-15) Smooth nylon jacket aids in easier pulling

1) Good resistance to moisture heat oil gasoline chemicals and grease2) Suitable for installation where thermal

3) Strict quality control during

FEATURES

MAXIMUM CONDUCTOR TEMPERATURE

Dry locations (THHN)Dry and wet locations (THWN-2)

90deg C90deg C

MAXIMUM OPERATING VOLTAGE

600 volts

required May be used for power and

gases gasoline and chemicals Alsosuitable as machine tool and switchboard

control circuits in recognized raceways inwet or dry locations and in presence of

wiring

UL-83

HOW TO ORDER

NATIONAL ELECTRICAL CODE REFERENCE

Ampacities

Switchboard wiring

Conduit fill tables

Article 3 10-15

Article 384

Chapter 9

THHN or THWN-2 600 volts size color and length

12

RoHS

IEEE 1202 and ULFT4 Flame Test

CESMEC E-022-01-5505

Type THHN or THWN-2 Annealed bare solid (14-10 AWG) type THHN or THWN-2 Annealed bare stranded class C concentric round (14-2 AWG) compressed stranding class B (1 AWG-1000MCM)copper conductor

1)

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947311-10

XHHW-2 600 VOLTS

POWER CABLE TYPE TC

DESCRIPTION

Dimension and weights shown are nominal unless otherwise indicated and subject to

Size Number Number Jacket Overall Netof of Thickness Diameter WeightAWG

Strands Conductors mils inches lbMft

2 45 033 65

3 45 035 81

4 45 038 103

14 7 5 45 042 125

7 60 049 182

9 60 060 230

12 60 067 288

19 80 077 455

2 45 041 84

3 45 043 112

4 45 047 140

5 45 051 172

12 7 7 60 063 247

9 60 073 310

12 60 081 397

19 80 098 626

2 45 046 97

3 45 048 125

4 60 057 173

10 7 5 60 062 209

7 60 071 279

9 60 081 350

12 80 095 481

manufacturing tolerances

FEATURES

Wet or DryDry

90deg C90deg C

APPLICATION

Electrical Code

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet ordry locations and in the presence of oil and most

lighting control signal and communcation circuitsin raceways direct burial in earth or in

SPECIFICATIONS

S-73-532 (table E-2 or Method SB 4)7) Circuit identification color coded per ICEA

UL 1277 UL 44

HOW TO ORDER

chemicals in accordance with the National

MAXIMUM OPERATING VOLTAGE

600 volts

MAXIMUM CONDUCTOR TEMPERATURE

Condumex Tray Cable Type TCXHHW-2

600 volts number and size of conductors

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

BTU flame test3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

Electrical Code

tray cable used in accordance with the National

Resistant I

O5) PVC jacket is UL rated 90 C and listed Oil

Location Applications6) Acceptable for Class I Division 2 Hazardous

7a) Other color coding methods are available based on ICEA S-73-532

24 13

1) Annealed bare Class C concentric strand copper conductors2) Flame retardant XLPE3) Binder tape over core4) Overall flame retardant PVC jacket

Contact factory for items not shown above

8) ldquoERrdquo Listed per UL 1277

1113

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947311-10

THHNTHWN 600 VOLTS

POWER CABLE TYPE TC

DESCRIPTION

2) Polyvinyl Chloride (PVC) thermoplastic

insulation

1) Annealed bare Class C concentric

strand copper conductors

3) Nylon protective covering

4) Binder tape over core

5) Overall flame retardant PVC jacket

Dimension and weights shown are nominal unless otherwise indicated and subject to

Size Number Number Jacket Overall Netof of Thickness Diameter WeightAWG

Strands Conductors mils inches lbMft

2 45 034 68

3 45 036 87

4 45 040 109

14 19 5 45 043 130

7 45 046 167

9 60 056 234

12 60 063 285

16 60 067 335

2 45 038 90

3 45 040 119

4 45 043 154

5 45 046 173

12 19 7 60 055 247

9 60 064 326

12 60 071 400

16 60 076 485

2 45 045 139

3 45 047 180

4 60 055 247

10 19 5 60 060 178

7 60 065 367

9 60 075 480

12 80 089 637

manufacturing tolerances

FEATURES

Wet or DryDry

75deg C90deg C

APPLICATION

Electrical Code

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet ordry locations and in the presence of oil and most

lighting control signal and communcation circuitsin raceways direct burial in earth or in

SPECIFICATIONS

S-73-532 (table E-2 or Method SB 4)7) Circuit identification color coded per ICEA

UL 1277 UL 83 and ER Approved

HOW TO ORDER

chemicals in accordance with the National

MAXIMUM OPERATING VOLTAGE

600 volts

MAXIMUM CONDUCTOR TEMPERATURE

Condumex Tray Cable Type TCTHHN

600 volts number and size of conductors

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

BTU flame test3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

Electrical Code

tray cable used in accordance with the National

Resistant I

O5) PVC jacket is UL rated 90 C and listed Oil

required metallic sheathed cablessubstantial cost savings over the previouslyLocation Applications Type TX offers

6) Acceptable for Class I Division 2 Hazardous

7a) Other color coding methods are available based on ICEA S-73-532

4

245 13

8) ldquoERrdquo Listed per UL 1277

RoHS

5) Binder tape over core

750 kcmil) copper conductors

6) Overall flame retardant PVC jacket

DESCRIPTION

3) Nylon protective covering4) Fillers

1) Annealed bare Class C (8-2 AWG)compressed stranded Class B (10 AWG-

2) Polyvinyl Chloride thermoplastic insulation

36 145 2

POWER CABLE TYPE TC

THHNTHWN 600 VOLTS

Size Number Ground Insulation Jacket Overall Netof Conductor Thickness Thickness Diameter Weight

AWGkcmilConductors AWG mils mils inch lbMft

8 3 10 305 60 0638 338

6 3 8 305 60 0698 448

4 3 6 407 80 0884 693

2 3 6 407 80 1015 1012

1 3 8 507 80 1150 1210

10 3 6 508 80 1223 1495

20 3 6 508 80 1320 1858

30 3 4 508 80 1428 2297

40 3 4 508 80 1549 2791

250 3 4 609 80 1760 3374

350 3 3 609 110 1980 4526

500 3 2 609 110 2260 6230

750 3 1 7010 110 2967 8845

10 4 6 508 80 1350 1913

20 4 6 508 80 1457 2311

40 4 4 508 110 1773 3597

350 4 3 609 110 2188 5754

500 4 2 609 110 2502 8018

750 4 1 7010 140 3057 11716

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

MAXIMUM OPERATING VOLTAGE

UL 1277 UL 83 and ER Approved

7) Circuit identification color coded per ICEA

MAXIMUM CONDUCTOR TEMPERATURE

Wet or DryDry

75deg C90deg C

required metallic sheathed cables

3) Sunlight resistant can be installed outdoors

tray cable use in accordance with the National

Electrical Code

APPLICATION

in accordance with the National Electrical Code

6) Acceptable for Class I Division 2 Hazardous

4) UL listed as Type TC for power and control

600 volts

5) PVC jacket is UL rated 90deg C and listed Oil

Resistant I

1) UL listed for direct burial

2) Flame retardant (passes UL 1277 70000

BTU flame test)

FEATURES

Condumex Type TC cable may be used for

cable may be used in wet or dry locations and in the presence of oil and most chemicals

power lighting control signal and communication circuits in raceways direct

HOW TO ORDER

600 volts number and size of conductorsCondumex Tray Cable Type TCTHHN

SPECIFICATIONS

S-73-532 (table E-2 or Method SB 4)

Location Applications Type TC offers

substantial cost savings over the previously

7a) Other color coding methods are available based on ICEA S-73-532

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947303-06

5

8) ldquoERrdquo Listed per UL 1277

RoHS

1) Annealed bare stranded class B compact

copper conductor

DESCRIPTION

3) Ethylene propylene (EPR) or cross-linked

polyethylene (XLPE) insulation

4) Polyvinyl chloride (PVC) protective jacket

2) Extruded semiconducting strand shield

VULCANELreg MEDIUM VOLTAGE

WET OR DRY POWER CABLE 5 KVXLPE OR EPR NON-SHIELDED

24 13

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

Size Number Conductor Insulation Insulation Jacket OverallAWG of Diameter Thickness Diameter Thickness Diameterkcmil Strands inch inch inch mils Inch XLPE EPR

Net WeightLbMft

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

manufacturing tolerances

5kV 133 Insulation Level 115 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject to

cable voltage and insulation level conductor

Ampacities

Cable Trays

Type MV

ICEA S-66-524 AEIC CS-S (XLP)

extrusion) results in a virtually perfect cable core

- Very low dielectric loss

Normal Operation 105deg C130deg CEmergency Overload

VULCANELreg 5kv Non-shielded power cables

adequate for proper termination of the shielding

1) Simultaneous extrusion of strand shield

250deg CShort Circuit

UL 1072

326

318

310-15

National Electrical Code References

VULCANELreg EPRXLPE Non-Shielded power

size and type length and reel dimensions

SPECIFICATIONS

are ideally suited for use in industrial andutility applications where shields cannot be

APPLICATION

abrasion ozone and moisture

- Electrical stability under stress- Low dielectric loss- Chemical resistance

FEATURES

3) Easy-stripping insulation shield4) The external PVC jacket is resistant to

EPR insulation offers- Excellent heat moisture and corona

2) XLPE insulation offers- Low moisture absorption- Good resistance to chemicals

insulation and insulation shield (triple

accordance with the National ElectricalCode

5) UL listed as MV-105 sunlight resistantdirect burial Optional marking For CTuse available on single conductor in

HOW TO ORDER

resistance

MAXIMUM CONDUCTOR TEMPERATURE

Page 1 of 2

ICEA S-68-516 AEIC CS-6-87 (EPR)

6

RoHS

VULCANELreg MEDIUM VOLTAGE

WET OR DRY POWER CABLE 5 KVXLPE OR EPR NON-SHIELDED

Page 2 of 2

Size Number Conductor Insulation Insulation Jacket OverallAWG of Diameter Thickness Diameter Thickness Diameterkcmil Strands inch inch inch mils Inch XLPE EPR

Net WeightlbMft

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

25kV 100 Insulation Level 260 mils Insulation Thickness

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

35kV 100 Insulation Level 345 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

15kV 133 Insulation Level 220 mils Insulation Thickness

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

17

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANELreg MEDIUM VOLTAGE EPR

SHIELDED POWER CABLES 5 15 25 35 KV

346 125

DESCRIPTION

1) Annealed bare stranded class B compactcopper conductor

2) Extruded semiconducting strand shield3) Ethylene propylene rubber (EPR) insulation4) Extruded semiconducting insulation shield5) Annealed copper tape shield (25 overlap

6) Polyvinyl chloride (PVC) protective jacketminimum)

Three-phase electrical distribution systems

trays

Suitable for use in overhead installationsrecognized raceways direct burial or cable

APPLICATION

voltage and insulation level conductor

AmpacitiesCable TraysType MV

- Chemical resistance

5) The external PVC jacket is resistant to

- Electrical stability under stress

MAXIMUM CONDUCTOR TEMPERATURE

SPECIFICATIONS

use available on single conductor in

accordance with the National ElectricalCode

abrasion ozone and moisture6) UL listed as MV-105 sunlight resistant

direct burial Optional marking For CT

3) Easy-stripping insulation shield4) Tape shield provides high short circuit

capabilities and uniform shield impedance

- Low dielectric loss

UL 1072

size and type length and reel dimensions

ICEA S-68-516 AEIC CS6-87

326318310-15

National Electrical Code References

VULCANELreg EPR shielded power cable

2) EPR insulation offers- Excellent heat moisture and corona

resistance

insulation and insulation shield (tripleextrusion) results in a virtually perfect

cable core

250 degCShort Circuit

1) Simultaneous extrusion of strand shield

Normal Operation 105 degC130 degCEmergency Overload

FEATURES

SPECIFICATIONS

HOW TO ORDER

Page 1 of 2

Size Number Conductor Insulation Insul Shld Jacket Overall Netof Diameter Thickness Diameter Thickness Diameter Weight

AWGkcmilStrands Inch inch inch mils Inch lbMft

6 7 017 045 053 60 067 290

4 7 022 049 057 60 071 357

2 7 027 055 063 60 074 478

10 19 034 062 070 80 085 668

20 19 038 066 074 80 092 775

30 19 043 071 079 80 097 933

40 19 048 076 084 80 102 1071

250 37 052 081 090 80 107 1226

350 37 062 091 099 80 117 1560

500 37 074 103 113 80 132 2150

750 61 091 121 132 80 150 3027

1000 61 111 136 146 80 164 3845

5kV 133 Insulation Level 115 mils Insulation Thickness

2 7 027 067 075 80 093 570

10 19 034 074 082 80 100 736

20 19 038 078 086 80 104 849

30 19 043 083 091 80 109 1010

40 19 048 088 096 80 114 1190

250 37 052 094 102 80 120 1330

350 37 062 103 114 80 132 1753

500 37 074 116 126 80 144 2280

750 61 091 134 144 80 162 3142

1000 61 111 136 159 110 183 5794

5kV 100 Insulation Level 175 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

Page 2 of 2

VULCANELreg MEDIUM VOLTAGE EPR

SHIELDED POWER CABLES 5 15 25 35 KV

Size Number Conductor Insulation Insul Shld Jacket Overall Netof Diameter Thickness Diameter Thickness Diameter Weight

AWGkcmilStrands Inch inch inch mils Inch lbMft

6 7 017 045 053 60 067 290

4 7 022 049 057 60 071 357

2 7 027 055 063 60 074 478

10 19 034 062 070 80 085 668

20 19 038 066 074 80 092 775

30 19 043 071 079 80 097 933

40 19 048 076 084 80 102 1071

250 37 052 081 090 80 107 1226

350 37 062 091 099 80 117 1560

500 37 074 103 113 80 132 2150

750 61 091 121 132 80 150 3027

1000 61 111 136 146 80 164 3845

15kV 133 Insulation Level 220 mils Insulation Thickness

10 19 034 092 100 80 118 894

20 19 038 096 104 80 122 1009

30 19 043 100 111 80 129 1181

40 19 048 106 116 80 134 1394

250 37 052 111 122 80 140 1537

350 37 062 121 131 80 149 1936

500 37 074 133 143 80 161 2516

750 61 091 151 161 110 185 3620

1000 61 111 166 180 110 204 4543

25kV 100 Insulation Level 260 mils Insulation Thickness

10 19 034 109 119 80 137 1041

20 19 038 113 123 80 141 1226

30 19 043 118 128 80 146 1380

40 19 048 123 133 80 151 1569

250 37 052 129 139 80 157 1750

350 37 062 138 149 80 167 2163

500 37 074 150 161 110 185 2893

750 61 091 168 183 110 207 3900

1000 61 111 183 197 110 221 4807

35kV 100 Insulation Level 345 mils Insulation Thickness

manufacturing tolerancesDimension and weights shown are nominal unless otherwise indicated and subject to

19

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-94735-05

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

ICEA-S-68-516

SPECIFICATIONS

three conductor cable voltage size andlength

Condumex Mining Cable EPR type SHD-GC

HOW TO ORDER

MINING CABLE EPR TYPE SHD-GC

THREE CONDUCTOR 5000 VOLTS

18SHD-GC01

with a nylon webbing provides a tough defense

round configuration

and Health Administration Approval No P-218-1-MSHA

by the Pennsylvania Department of Environmental

Resources Meets MSHA flame test requirements

6) Acceptance No P-218-1-MSHA by Mines Safety

5) CV-Cured extra-heavy-duty CPE reinforced

4) Prevulcanized thermosetting non-wicking fillers

mechanical resistant jacket

resistance outstanding corona resistance

high dielectric strength and chemical resistance

designed for flexibility and resistance to

FEATURES

2) Ground check conductor facilitates fail-safe

3) EPR insulation offers excellent heat and moisture

are used if necessary to obtain a substantially

1) Special tinned copper stranded conductors

fatigue resulting from bending and flexing

ground monitoring for maximum safety

Dimension and weights shown are nominal unless otherwise indicated and subject to

6 7x3029 020 110 10 8 156

4 7x4729 025 110 8 8 168

2 7x7429 031 110 6 8 187

1 7x3725 035 110 5 8 195

10 7x4725 039 110 4 8 208

20 7x6025 045 110 3 8 220

30 7x7525 050 110 2 8 236

40 19x3525 059 110 1 8 250

300 19x4925 069 120 10 8 281

350 19x5825 076 120 20 8 295

1675

1888

2322

2653

3068

3504

4206

5023

6371

7654

Size Number of Conductor Insulation Ground Ground OverallAWG Strands Diameter Thickness Size Check Size Diameterkcmil AWG inch mils AWG AWG inch

NetWeightlbmft

manufacturing tolerances

MAXIMUM CONDUCTOR TEMPERATURE

Normal continuous 90deg C130deg COverload

250deg CShort circuit

MAXIMUM OPERATING VOLTAGE

5000 volts

Trailing cable on ac mining equipment

where service conditions are severe andmaximum safety is mandatory such as

APPLICATION

power shovels and draglines in open-pit

mines quarries gantry cranes and slag

reclaiming Also used for medium voltage

distribution in underground mines where

frequent relocation is necessary

DESCRIPTION

1) Three flexible annealed tinned copper rope-lay stranded conductors

2) Extruded semi-conducting conductor shieldand ethylene propylene rubber (EPR) insulation

3) Color coded cottoncopper braid shield applied over semi-conducting tape

4) Two annealed tinned copper rope-lay strandedgrounding conductors

5) Annealed tinned copper rope-lay stranded

and covered with a yellow cotton braid

chlorinated polyethylene (CPE) jacket

6) Rubberized cotton binder tape7) Nylon web reinforced extra-heavy-duty

ground check conductor yellow EPR insulation

346 2 157

110

RoHS

5) Overall flame retardant PVC jacket

DESCRIPTION

XLP insulation3) Fillers (if required)

4) Binder tape over core

2) Cross-Linked polyethylene thermosetting

1) Annealed bare stranded compressed

Class B copper conductors

without grounding conductorVolts number and size of conductors with or

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet

lighting control signal and communication circuitsin cable trays raceways direct burial or on

HOW TO ORDER

Condumex Tray Cable Type TCXHHW 600

SPECIFICATIONS

UL-1277 amp UL-44

APPLICATION

most chemicals in accordance with the

MAXIMUM OPERATING VOLTAGE

National Electrical Code

or dry locations and in the presence of oil and

6) Acceptable for Class 1 Division 2 HazardousLocations applications

O5) PVC jacket is UL rated 90 C and listed OilResistant I

600 volts

MAXIMUM CONDUCTOR TEMPERATUREO 90 C

O130 C

FEATURES

OverloadNormal

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

National Electrical Code

BTU flame test)3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

tray cable use in accordance with the

3 145 2

POWER CABLE TYPE TC

XHHW 600 VOLTS

Size Number Ground Insulation Jacket Overall Netof Conductor Thickness Thickness Diameter Weight

AWGkcmilConductors AWG mils mils inch lbMft

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 3 10 45 60 066 310

6 3 8 45 60 074 448

4 3 8 45 80 088 659

2 3 6 45 80 103 968

10 3 6 55 80 121 1428

20 3 4 55 80 131 1735

30 3 4 55 80 142 2150

40 3 4 55 80 154 3620

250 3 4 65 110 175 3190

350 3 3 65 110 196 4305

500 3 2 65 110 225 5940

8 4 10 45 60 073 385

6 4 8 45 80 083 568

4 4 8 45 80 097 832

2 4 6 45 80 112 1230

10 4 6 5 80 134 1825

20 4 4 55 80 145 2212

30 4 4 55 80 157 2751

40 4 4 55 110 177 3462

250 4 4 65 110 198 4097

350 4 3 65 110 217 5542

500 4 2 65 110 249 7690

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

111

7) ldquoERrdquo Listed per UL 1277

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

National Electrical Code References

Product Article 310 Table 310-13

Ampacities Article 310-15

HOW TO ORDER

CONDUMEX type RHH-RHW-USE-2

XLPE 600 volts size length quantity

packaging

DESCRIPTION

polyethylene (XLPE) insualtion

1) Annealed bare stranded class B

conductor

2) Flame-retardant cross-linked

TYPE RHH-RHW-USE-2

COPPER XLPE 600 VOLTS

APPLICATION

May be installed in free air all raceways or

underground service entrance cable

Type RHH 90deg C Dry and

temperatures

6) Stable electrical propoerties

UL-44 Standard for Rubber-Insulated

use in direct burial in industrial andcommercial application May be used as

7) Extremely tough

SPECIFICATIONS

4) Good resistance to most oils and

3) UL approved as VW-1 (RHH or RHW)

chemicals5) Suitable for installation in sub-zero

2) UL listed as types RHH or RHW or USE forresistant insulation

damp locations

ICEA S-66-524 Standard for Cross-Linked

Type RHW or 75deg C Dry and

use in accordance with the National

Electrical Code

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

MAXIMUM OPERATING VOLTAGE

USE wet locatinons

1) Flame retardant moisture and heat

FEATURES

Wires and Cables

Polyethylene Insualted Wire and Cable

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch mils inch lbMft

8 7 165 015 60 027 73

6 7 262 018 60 031 108

4 7 417 022 60 035 161

2 7 663 028 60 041 245

10 19 106 036 80 053 392

20 19 133 041 80 058 485

30 19 168 046 80 063 600

40 19 211 051 80 069 746

250 37 056 95 076 887

300 37 061 95 082 1052

350 37 066 95 087 1216

400 37 071 95 092 1380

500 37 079 95 099 1708

600 61 087 110 111 2055

750 61 097 110 120 2542

1000 61 112 110 136 3353

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

11 112

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

copper conductor

2) Cross-linked polyethylene (XLPE)

insulation

compressed (6 AWG-1000 MCM)

1) Annealed bare stranded class B

concentric round (14-8 AWG)

APPLICATION

Power or control circuits in recognized

switchboard wiring

Dry locations 90deg C

presence of oil Also suitable as

designs

temperatures

4) Suitable for installation in sub-zero

pulling and greater conduit fill

5) Optical For CT use marking for use in

cable trays Sunlight resistant in

FEATURES

2) Good moisture resistance

raceways in wet or dry location and in

90deg CWet locationsOverload 130deg CShort Circuit

MAXIMUM OPERATING VOLTAGE

3) Good resistance to most oils and

chemicals

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

accordance with NEC Article 3186) Available in VW-1 and non VW-1

UL-44

SPECIFICATIONS

Chapter 9

250deg C

1) Smaller overall diameter for easier

HOW TO ORDER

National Electrical Code References

Article 310

VULCANELreg XLPE cable type XHHW-2600 volts size and length

Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL

TYPE XHHW-2 600 VOLTS

reg XLPE CABLE

2 1

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch Mils inch lbMft

manufacturing tolerances

14 7 41 007 30 013 19

12 7 65 009 30 015 48

10 7 103 011 30 017 42

8 7 165 015 45 024 71

6 7 262 018 45 027 98

4 7 417 023 45 032 153

2 7 663 029 45 038 241

10 19 1060 037 55 048 378

20 19 1330 041 55 052 446

30 19 1680 047 55 058 556

40 19 2110 052 55 063 697

250 37 057 65 070 851

300 37 062 65 075 997

350 37 067 65 080 1180

400 37 072 65 085 1306

500 37 080 65 093 1662

600 61 088 80 104 1974

750 61 098 80 115 2450

1000 61 114 80 130 3240

Dimension and weights shown are nominal unless otherwise indicated and subject to

13

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

APPLICATION

FEATURES

MAXIMUM OPERATING VOLTAGE

MAXIMUM CONDUCTOR TEMPERATURE

UL-44

SPECIFICATIONS

Chapter 9

HOW TO ORDER

National Electrical Code References

Article 310Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL S8000

XHHW or XHHW-2 600 VOLTS ALUMINUM

reg XLPE CABLE

manufacturing tolerances

Size Number Insulations Overall Netof Thickness Diameter Weight

AWGkcmilStrands Mils In LbMft

6 7 45 027 42

4 7 45 031 59

2 7 45 036 88

1 7 55 042 111

10 19 55 045 136

20 19 55 049 165

30 19 55 054 203

40 19 55 059 250

250 37 65 066 300

300 37 65 071 354

350 37 65 075 405

500 37 65 087 562

600 61 80 098 684

750 61 80 108 840

900 61 80 117 995

Dimension and weights shown are nominal unless otherwise indicated and subject to

2 13

1) Stranded compact class B AA-8000 series aluminum alloy soft conductor2) Separator tape3) Cross-linked polyethylene (XLPE) insulation type XHHW or XHHW-2

Branch-circuits and feeders conductors in low voltage for buildings schools auditoriums hospitals stadiums museums poultry farms etc Industrial and commercial buildings For use in cable trays or raceways in wet and dry locations

600 volts

Wet and dry continuousOverloadShort circuit

90 C130 C125 C

1) Easier pulling and greater conduit fill2) Good moisture resistance3) Excellent dielectrics properties4) Continuous 90 C operating temperature in wet or dry locations5) Suitable for use in cable trays (10 AWG and greater)6) VW-1 compliant7) Sunlight resistant insulatedRoHS compliant

APPROVALS

Type XHHW or XHHW-2 UL listedType Rw90 or RWU90 upon special request

Vulcanel S8000 cable type XHHW or XHHW-2 RoHS CT-SR with stranded compact class B AA-8000 series aluminum alloy soft conductor size length and product number

reg

114

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANEL EPR ANTILLAMA CABLE

600 VOLTS

26ACSR01

DESCRIPTION

FEATURES

HOW TO ORDER

SPECIFICATIONSSPECIFICATIONS

3 2 1

1) Annealed coated or un-coated stranded class B copper conductor2) Ethylene propylene rubber (EPR) insulation3) Chlorosulfonated polyethylene (Hypalon) or chlorinated polyethylene(CPE) jacket

APPLICATION

Ideally suited for use in Electrical generating stations May be installed in free air all raceways or direct burial

MAXIMUM CONDUCTOR TEMPERATUREDry LocationsDry and Wet LocationsOverloadShort Circuit

90 C75 C130 C250 C

MAXIMUM OPERATING VOLTAGE600 Volts

1) Flame resistant Meets or exceeds requirements of IEEE 383 flame test2) Deformation resistant at high temperatures3) Excellent Flexibility at low temperature suitable for installation in sub-zero temperatures4) Extra tough mechanically rugged composite insulation and jacket construction6) Resistant to most oils and chemicals

ICEA S-95-658

VULCANEL EPR ANTILLAMA cable 600 volts size length National Electrical Code ReferencesAmpacities Article 31318-10Cable Trays Article 318

Dupont trade mark

reg reg

Size Number Conductor Insulation Jacket Overall Netof Diameter Thickness Thickness Diameter Weight

AWGkcmilStrands Inch mils mils inch lbMft

8 7 015 45 15 026 79

6 7 118 45 30 042 125

4 7 023 45 30 038 179

2 7 029 45 30 043 269

10 19 037 55 45 056 432

20 19 041 55 45 061 528

30 19 047 55 45 066 647

40 19 052 55 45 071 797

250 37 057 65 45 082 982

300 37 062 65 65 087 1146

352 37 067 65 65 092 1351

400 37 072 65 65 097 1480

500 37 080 65 65 105 1782

600 61 088 80 65 116 2186

750 61 098 80 65 126 2685

1000 61 114 80 65 141 3410

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

reg reg

15

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

CODE SIZE STRAND OVERALL DIAMETER NET WEIGHT RUPTURE STRENGTH

Turkey 6 61 0198 503 36 54

Swan 4 61 0250 635 58 86

Swallow 3 61 0281 714 73 108

Sparrow 2 61 0316 803 91 136

Robin 1 61 0355 902 115 171

Raven 10 61 0398 1011 145 216

Quail 20 61 0447 1135 183 273

Pigeon 30 61 0502 1275 231 344

Penguin 40 61 0563 1430 291 433

Partridge 2668 267 0642 1631 366 544

Linnet 3364 267 0721 1831 162 688

Oriole 3364 307 0741 1882 525 782

Ibis 3975 267 0783 1989 545 811

Lark 3975 307 0806 2047 619 921

Hawk 4770 267 0858 2179 654 973

Hen 4770 307 0883 2243 743 1106

Heron 5000 307 0904 2296 781 1162

Dove 5565 267 0927 2355 765 1138

Eagle 5565 307 0953 2421 869 1293

Duck 6050 547 0953 2421 779 1159

Grosbeak 6360 267 0990 2515 872 1298

Starling 7155 267 1051 2670 986 1467

Crow 7155 547 1035 2629 918 1366

Drake 7950 267 1108 2814 1095 1629

Condor 7950 547 1093 2776 1021 1520

Canary 9000 547 1162 2951 1160 1726

Rail 9540 457 1165 2959 1076 1601

Bluejay 11130 457 1259 3198 1256 1869

11903

18608

23040

28575

35550

43875

53100

66825

84308

113175

141075

173250

163125

203175

195075

238500

247500

227250

279000

234000

252000

283500

261000

315000

281250

323370

258750

309870

WORD AWG or MCM ALSteel Inch mm Lbsmft kgkm lbs

manufacturing tolerances

Condumex can currently produce a wider

BARE ACSR CABLE

ALUMINUM CONDUCTOR STEEL REINFORCED

26ACSR01

DESCRIPTION

CONDUCTORS

Aluminum 1350 wire concentrically laid overa solid or stranded galvanized steel core

Mechanical design requirements5) Good corrosion resistance

3) High resistance to mechanical strength4) Wide variety of sizes available in long

lengths to suit both electrical and

fewer towers required

strength to permit the longest possiblespans

2) Minimum sag between supports with

1) Ideal combination of conductivity and

FEATURES

Code Word quantity required in weight

ACSR cable size Aluminum Association

HOW TO ORDER

Overhead transmission subtransmission

overhead electrical cables Messenger and

overhead lines Messenger cables to support

APPLICATION

and distribution systems Static wires to protect

power support conductor in catenary systems

for railroad electrification

SPECIFICATIONS

ASTM B498 Galvanized steel class A

ASTM B232 Conductor overall

SPECIFICATIONS

ASTM B230 Aluminum wires

MAXIMUM CONDUCTOR TEMPERATURE

Normal Operation 75 degC

116

Dimension and weights shown are nominal unless otherwise indicated and subject to

range of products then what is listedPlease contact us for other items

Grand Prairie Texas800-925-9473

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
Page 6: 5Power Cable Specs Set 2 - Condumex  · PDF fileCondumex Wire and Cable 2590 114th Street, ... Type Conductors Diameter Ampacity Weight AWG ... 6 19 26.2 0.18 30 6 0.26

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947311-10

XHHW-2 600 VOLTS

POWER CABLE TYPE TC

DESCRIPTION

Dimension and weights shown are nominal unless otherwise indicated and subject to

Size Number Number Jacket Overall Netof of Thickness Diameter WeightAWG

Strands Conductors mils inches lbMft

2 45 033 65

3 45 035 81

4 45 038 103

14 7 5 45 042 125

7 60 049 182

9 60 060 230

12 60 067 288

19 80 077 455

2 45 041 84

3 45 043 112

4 45 047 140

5 45 051 172

12 7 7 60 063 247

9 60 073 310

12 60 081 397

19 80 098 626

2 45 046 97

3 45 048 125

4 60 057 173

10 7 5 60 062 209

7 60 071 279

9 60 081 350

12 80 095 481

manufacturing tolerances

FEATURES

Wet or DryDry

90deg C90deg C

APPLICATION

Electrical Code

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet ordry locations and in the presence of oil and most

lighting control signal and communcation circuitsin raceways direct burial in earth or in

SPECIFICATIONS

S-73-532 (table E-2 or Method SB 4)7) Circuit identification color coded per ICEA

UL 1277 UL 44

HOW TO ORDER

chemicals in accordance with the National

MAXIMUM OPERATING VOLTAGE

600 volts

MAXIMUM CONDUCTOR TEMPERATURE

Condumex Tray Cable Type TCXHHW-2

600 volts number and size of conductors

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

BTU flame test3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

Electrical Code

tray cable used in accordance with the National

Resistant I

O5) PVC jacket is UL rated 90 C and listed Oil

Location Applications6) Acceptable for Class I Division 2 Hazardous

7a) Other color coding methods are available based on ICEA S-73-532

24 13

1) Annealed bare Class C concentric strand copper conductors2) Flame retardant XLPE3) Binder tape over core4) Overall flame retardant PVC jacket

Contact factory for items not shown above

8) ldquoERrdquo Listed per UL 1277

1113

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947311-10

THHNTHWN 600 VOLTS

POWER CABLE TYPE TC

DESCRIPTION

2) Polyvinyl Chloride (PVC) thermoplastic

insulation

1) Annealed bare Class C concentric

strand copper conductors

3) Nylon protective covering

4) Binder tape over core

5) Overall flame retardant PVC jacket

Dimension and weights shown are nominal unless otherwise indicated and subject to

Size Number Number Jacket Overall Netof of Thickness Diameter WeightAWG

Strands Conductors mils inches lbMft

2 45 034 68

3 45 036 87

4 45 040 109

14 19 5 45 043 130

7 45 046 167

9 60 056 234

12 60 063 285

16 60 067 335

2 45 038 90

3 45 040 119

4 45 043 154

5 45 046 173

12 19 7 60 055 247

9 60 064 326

12 60 071 400

16 60 076 485

2 45 045 139

3 45 047 180

4 60 055 247

10 19 5 60 060 178

7 60 065 367

9 60 075 480

12 80 089 637

manufacturing tolerances

FEATURES

Wet or DryDry

75deg C90deg C

APPLICATION

Electrical Code

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet ordry locations and in the presence of oil and most

lighting control signal and communcation circuitsin raceways direct burial in earth or in

SPECIFICATIONS

S-73-532 (table E-2 or Method SB 4)7) Circuit identification color coded per ICEA

UL 1277 UL 83 and ER Approved

HOW TO ORDER

chemicals in accordance with the National

MAXIMUM OPERATING VOLTAGE

600 volts

MAXIMUM CONDUCTOR TEMPERATURE

Condumex Tray Cable Type TCTHHN

600 volts number and size of conductors

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

BTU flame test3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

Electrical Code

tray cable used in accordance with the National

Resistant I

O5) PVC jacket is UL rated 90 C and listed Oil

required metallic sheathed cablessubstantial cost savings over the previouslyLocation Applications Type TX offers

6) Acceptable for Class I Division 2 Hazardous

7a) Other color coding methods are available based on ICEA S-73-532

4

245 13

8) ldquoERrdquo Listed per UL 1277

RoHS

5) Binder tape over core

750 kcmil) copper conductors

6) Overall flame retardant PVC jacket

DESCRIPTION

3) Nylon protective covering4) Fillers

1) Annealed bare Class C (8-2 AWG)compressed stranded Class B (10 AWG-

2) Polyvinyl Chloride thermoplastic insulation

36 145 2

POWER CABLE TYPE TC

THHNTHWN 600 VOLTS

Size Number Ground Insulation Jacket Overall Netof Conductor Thickness Thickness Diameter Weight

AWGkcmilConductors AWG mils mils inch lbMft

8 3 10 305 60 0638 338

6 3 8 305 60 0698 448

4 3 6 407 80 0884 693

2 3 6 407 80 1015 1012

1 3 8 507 80 1150 1210

10 3 6 508 80 1223 1495

20 3 6 508 80 1320 1858

30 3 4 508 80 1428 2297

40 3 4 508 80 1549 2791

250 3 4 609 80 1760 3374

350 3 3 609 110 1980 4526

500 3 2 609 110 2260 6230

750 3 1 7010 110 2967 8845

10 4 6 508 80 1350 1913

20 4 6 508 80 1457 2311

40 4 4 508 110 1773 3597

350 4 3 609 110 2188 5754

500 4 2 609 110 2502 8018

750 4 1 7010 140 3057 11716

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

MAXIMUM OPERATING VOLTAGE

UL 1277 UL 83 and ER Approved

7) Circuit identification color coded per ICEA

MAXIMUM CONDUCTOR TEMPERATURE

Wet or DryDry

75deg C90deg C

required metallic sheathed cables

3) Sunlight resistant can be installed outdoors

tray cable use in accordance with the National

Electrical Code

APPLICATION

in accordance with the National Electrical Code

6) Acceptable for Class I Division 2 Hazardous

4) UL listed as Type TC for power and control

600 volts

5) PVC jacket is UL rated 90deg C and listed Oil

Resistant I

1) UL listed for direct burial

2) Flame retardant (passes UL 1277 70000

BTU flame test)

FEATURES

Condumex Type TC cable may be used for

cable may be used in wet or dry locations and in the presence of oil and most chemicals

power lighting control signal and communication circuits in raceways direct

HOW TO ORDER

600 volts number and size of conductorsCondumex Tray Cable Type TCTHHN

SPECIFICATIONS

S-73-532 (table E-2 or Method SB 4)

Location Applications Type TC offers

substantial cost savings over the previously

7a) Other color coding methods are available based on ICEA S-73-532

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947303-06

5

8) ldquoERrdquo Listed per UL 1277

RoHS

1) Annealed bare stranded class B compact

copper conductor

DESCRIPTION

3) Ethylene propylene (EPR) or cross-linked

polyethylene (XLPE) insulation

4) Polyvinyl chloride (PVC) protective jacket

2) Extruded semiconducting strand shield

VULCANELreg MEDIUM VOLTAGE

WET OR DRY POWER CABLE 5 KVXLPE OR EPR NON-SHIELDED

24 13

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

Size Number Conductor Insulation Insulation Jacket OverallAWG of Diameter Thickness Diameter Thickness Diameterkcmil Strands inch inch inch mils Inch XLPE EPR

Net WeightLbMft

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

manufacturing tolerances

5kV 133 Insulation Level 115 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject to

cable voltage and insulation level conductor

Ampacities

Cable Trays

Type MV

ICEA S-66-524 AEIC CS-S (XLP)

extrusion) results in a virtually perfect cable core

- Very low dielectric loss

Normal Operation 105deg C130deg CEmergency Overload

VULCANELreg 5kv Non-shielded power cables

adequate for proper termination of the shielding

1) Simultaneous extrusion of strand shield

250deg CShort Circuit

UL 1072

326

318

310-15

National Electrical Code References

VULCANELreg EPRXLPE Non-Shielded power

size and type length and reel dimensions

SPECIFICATIONS

are ideally suited for use in industrial andutility applications where shields cannot be

APPLICATION

abrasion ozone and moisture

- Electrical stability under stress- Low dielectric loss- Chemical resistance

FEATURES

3) Easy-stripping insulation shield4) The external PVC jacket is resistant to

EPR insulation offers- Excellent heat moisture and corona

2) XLPE insulation offers- Low moisture absorption- Good resistance to chemicals

insulation and insulation shield (triple

accordance with the National ElectricalCode

5) UL listed as MV-105 sunlight resistantdirect burial Optional marking For CTuse available on single conductor in

HOW TO ORDER

resistance

MAXIMUM CONDUCTOR TEMPERATURE

Page 1 of 2

ICEA S-68-516 AEIC CS-6-87 (EPR)

6

RoHS

VULCANELreg MEDIUM VOLTAGE

WET OR DRY POWER CABLE 5 KVXLPE OR EPR NON-SHIELDED

Page 2 of 2

Size Number Conductor Insulation Insulation Jacket OverallAWG of Diameter Thickness Diameter Thickness Diameterkcmil Strands inch inch inch mils Inch XLPE EPR

Net WeightlbMft

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

25kV 100 Insulation Level 260 mils Insulation Thickness

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

35kV 100 Insulation Level 345 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

15kV 133 Insulation Level 220 mils Insulation Thickness

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

17

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANELreg MEDIUM VOLTAGE EPR

SHIELDED POWER CABLES 5 15 25 35 KV

346 125

DESCRIPTION

1) Annealed bare stranded class B compactcopper conductor

2) Extruded semiconducting strand shield3) Ethylene propylene rubber (EPR) insulation4) Extruded semiconducting insulation shield5) Annealed copper tape shield (25 overlap

6) Polyvinyl chloride (PVC) protective jacketminimum)

Three-phase electrical distribution systems

trays

Suitable for use in overhead installationsrecognized raceways direct burial or cable

APPLICATION

voltage and insulation level conductor

AmpacitiesCable TraysType MV

- Chemical resistance

5) The external PVC jacket is resistant to

- Electrical stability under stress

MAXIMUM CONDUCTOR TEMPERATURE

SPECIFICATIONS

use available on single conductor in

accordance with the National ElectricalCode

abrasion ozone and moisture6) UL listed as MV-105 sunlight resistant

direct burial Optional marking For CT

3) Easy-stripping insulation shield4) Tape shield provides high short circuit

capabilities and uniform shield impedance

- Low dielectric loss

UL 1072

size and type length and reel dimensions

ICEA S-68-516 AEIC CS6-87

326318310-15

National Electrical Code References

VULCANELreg EPR shielded power cable

2) EPR insulation offers- Excellent heat moisture and corona

resistance

insulation and insulation shield (tripleextrusion) results in a virtually perfect

cable core

250 degCShort Circuit

1) Simultaneous extrusion of strand shield

Normal Operation 105 degC130 degCEmergency Overload

FEATURES

SPECIFICATIONS

HOW TO ORDER

Page 1 of 2

Size Number Conductor Insulation Insul Shld Jacket Overall Netof Diameter Thickness Diameter Thickness Diameter Weight

AWGkcmilStrands Inch inch inch mils Inch lbMft

6 7 017 045 053 60 067 290

4 7 022 049 057 60 071 357

2 7 027 055 063 60 074 478

10 19 034 062 070 80 085 668

20 19 038 066 074 80 092 775

30 19 043 071 079 80 097 933

40 19 048 076 084 80 102 1071

250 37 052 081 090 80 107 1226

350 37 062 091 099 80 117 1560

500 37 074 103 113 80 132 2150

750 61 091 121 132 80 150 3027

1000 61 111 136 146 80 164 3845

5kV 133 Insulation Level 115 mils Insulation Thickness

2 7 027 067 075 80 093 570

10 19 034 074 082 80 100 736

20 19 038 078 086 80 104 849

30 19 043 083 091 80 109 1010

40 19 048 088 096 80 114 1190

250 37 052 094 102 80 120 1330

350 37 062 103 114 80 132 1753

500 37 074 116 126 80 144 2280

750 61 091 134 144 80 162 3142

1000 61 111 136 159 110 183 5794

5kV 100 Insulation Level 175 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

Page 2 of 2

VULCANELreg MEDIUM VOLTAGE EPR

SHIELDED POWER CABLES 5 15 25 35 KV

Size Number Conductor Insulation Insul Shld Jacket Overall Netof Diameter Thickness Diameter Thickness Diameter Weight

AWGkcmilStrands Inch inch inch mils Inch lbMft

6 7 017 045 053 60 067 290

4 7 022 049 057 60 071 357

2 7 027 055 063 60 074 478

10 19 034 062 070 80 085 668

20 19 038 066 074 80 092 775

30 19 043 071 079 80 097 933

40 19 048 076 084 80 102 1071

250 37 052 081 090 80 107 1226

350 37 062 091 099 80 117 1560

500 37 074 103 113 80 132 2150

750 61 091 121 132 80 150 3027

1000 61 111 136 146 80 164 3845

15kV 133 Insulation Level 220 mils Insulation Thickness

10 19 034 092 100 80 118 894

20 19 038 096 104 80 122 1009

30 19 043 100 111 80 129 1181

40 19 048 106 116 80 134 1394

250 37 052 111 122 80 140 1537

350 37 062 121 131 80 149 1936

500 37 074 133 143 80 161 2516

750 61 091 151 161 110 185 3620

1000 61 111 166 180 110 204 4543

25kV 100 Insulation Level 260 mils Insulation Thickness

10 19 034 109 119 80 137 1041

20 19 038 113 123 80 141 1226

30 19 043 118 128 80 146 1380

40 19 048 123 133 80 151 1569

250 37 052 129 139 80 157 1750

350 37 062 138 149 80 167 2163

500 37 074 150 161 110 185 2893

750 61 091 168 183 110 207 3900

1000 61 111 183 197 110 221 4807

35kV 100 Insulation Level 345 mils Insulation Thickness

manufacturing tolerancesDimension and weights shown are nominal unless otherwise indicated and subject to

19

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-94735-05

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

ICEA-S-68-516

SPECIFICATIONS

three conductor cable voltage size andlength

Condumex Mining Cable EPR type SHD-GC

HOW TO ORDER

MINING CABLE EPR TYPE SHD-GC

THREE CONDUCTOR 5000 VOLTS

18SHD-GC01

with a nylon webbing provides a tough defense

round configuration

and Health Administration Approval No P-218-1-MSHA

by the Pennsylvania Department of Environmental

Resources Meets MSHA flame test requirements

6) Acceptance No P-218-1-MSHA by Mines Safety

5) CV-Cured extra-heavy-duty CPE reinforced

4) Prevulcanized thermosetting non-wicking fillers

mechanical resistant jacket

resistance outstanding corona resistance

high dielectric strength and chemical resistance

designed for flexibility and resistance to

FEATURES

2) Ground check conductor facilitates fail-safe

3) EPR insulation offers excellent heat and moisture

are used if necessary to obtain a substantially

1) Special tinned copper stranded conductors

fatigue resulting from bending and flexing

ground monitoring for maximum safety

Dimension and weights shown are nominal unless otherwise indicated and subject to

6 7x3029 020 110 10 8 156

4 7x4729 025 110 8 8 168

2 7x7429 031 110 6 8 187

1 7x3725 035 110 5 8 195

10 7x4725 039 110 4 8 208

20 7x6025 045 110 3 8 220

30 7x7525 050 110 2 8 236

40 19x3525 059 110 1 8 250

300 19x4925 069 120 10 8 281

350 19x5825 076 120 20 8 295

1675

1888

2322

2653

3068

3504

4206

5023

6371

7654

Size Number of Conductor Insulation Ground Ground OverallAWG Strands Diameter Thickness Size Check Size Diameterkcmil AWG inch mils AWG AWG inch

NetWeightlbmft

manufacturing tolerances

MAXIMUM CONDUCTOR TEMPERATURE

Normal continuous 90deg C130deg COverload

250deg CShort circuit

MAXIMUM OPERATING VOLTAGE

5000 volts

Trailing cable on ac mining equipment

where service conditions are severe andmaximum safety is mandatory such as

APPLICATION

power shovels and draglines in open-pit

mines quarries gantry cranes and slag

reclaiming Also used for medium voltage

distribution in underground mines where

frequent relocation is necessary

DESCRIPTION

1) Three flexible annealed tinned copper rope-lay stranded conductors

2) Extruded semi-conducting conductor shieldand ethylene propylene rubber (EPR) insulation

3) Color coded cottoncopper braid shield applied over semi-conducting tape

4) Two annealed tinned copper rope-lay strandedgrounding conductors

5) Annealed tinned copper rope-lay stranded

and covered with a yellow cotton braid

chlorinated polyethylene (CPE) jacket

6) Rubberized cotton binder tape7) Nylon web reinforced extra-heavy-duty

ground check conductor yellow EPR insulation

346 2 157

110

RoHS

5) Overall flame retardant PVC jacket

DESCRIPTION

XLP insulation3) Fillers (if required)

4) Binder tape over core

2) Cross-Linked polyethylene thermosetting

1) Annealed bare stranded compressed

Class B copper conductors

without grounding conductorVolts number and size of conductors with or

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet

lighting control signal and communication circuitsin cable trays raceways direct burial or on

HOW TO ORDER

Condumex Tray Cable Type TCXHHW 600

SPECIFICATIONS

UL-1277 amp UL-44

APPLICATION

most chemicals in accordance with the

MAXIMUM OPERATING VOLTAGE

National Electrical Code

or dry locations and in the presence of oil and

6) Acceptable for Class 1 Division 2 HazardousLocations applications

O5) PVC jacket is UL rated 90 C and listed OilResistant I

600 volts

MAXIMUM CONDUCTOR TEMPERATUREO 90 C

O130 C

FEATURES

OverloadNormal

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

National Electrical Code

BTU flame test)3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

tray cable use in accordance with the

3 145 2

POWER CABLE TYPE TC

XHHW 600 VOLTS

Size Number Ground Insulation Jacket Overall Netof Conductor Thickness Thickness Diameter Weight

AWGkcmilConductors AWG mils mils inch lbMft

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 3 10 45 60 066 310

6 3 8 45 60 074 448

4 3 8 45 80 088 659

2 3 6 45 80 103 968

10 3 6 55 80 121 1428

20 3 4 55 80 131 1735

30 3 4 55 80 142 2150

40 3 4 55 80 154 3620

250 3 4 65 110 175 3190

350 3 3 65 110 196 4305

500 3 2 65 110 225 5940

8 4 10 45 60 073 385

6 4 8 45 80 083 568

4 4 8 45 80 097 832

2 4 6 45 80 112 1230

10 4 6 5 80 134 1825

20 4 4 55 80 145 2212

30 4 4 55 80 157 2751

40 4 4 55 110 177 3462

250 4 4 65 110 198 4097

350 4 3 65 110 217 5542

500 4 2 65 110 249 7690

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

111

7) ldquoERrdquo Listed per UL 1277

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

National Electrical Code References

Product Article 310 Table 310-13

Ampacities Article 310-15

HOW TO ORDER

CONDUMEX type RHH-RHW-USE-2

XLPE 600 volts size length quantity

packaging

DESCRIPTION

polyethylene (XLPE) insualtion

1) Annealed bare stranded class B

conductor

2) Flame-retardant cross-linked

TYPE RHH-RHW-USE-2

COPPER XLPE 600 VOLTS

APPLICATION

May be installed in free air all raceways or

underground service entrance cable

Type RHH 90deg C Dry and

temperatures

6) Stable electrical propoerties

UL-44 Standard for Rubber-Insulated

use in direct burial in industrial andcommercial application May be used as

7) Extremely tough

SPECIFICATIONS

4) Good resistance to most oils and

3) UL approved as VW-1 (RHH or RHW)

chemicals5) Suitable for installation in sub-zero

2) UL listed as types RHH or RHW or USE forresistant insulation

damp locations

ICEA S-66-524 Standard for Cross-Linked

Type RHW or 75deg C Dry and

use in accordance with the National

Electrical Code

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

MAXIMUM OPERATING VOLTAGE

USE wet locatinons

1) Flame retardant moisture and heat

FEATURES

Wires and Cables

Polyethylene Insualted Wire and Cable

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch mils inch lbMft

8 7 165 015 60 027 73

6 7 262 018 60 031 108

4 7 417 022 60 035 161

2 7 663 028 60 041 245

10 19 106 036 80 053 392

20 19 133 041 80 058 485

30 19 168 046 80 063 600

40 19 211 051 80 069 746

250 37 056 95 076 887

300 37 061 95 082 1052

350 37 066 95 087 1216

400 37 071 95 092 1380

500 37 079 95 099 1708

600 61 087 110 111 2055

750 61 097 110 120 2542

1000 61 112 110 136 3353

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

11 112

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

copper conductor

2) Cross-linked polyethylene (XLPE)

insulation

compressed (6 AWG-1000 MCM)

1) Annealed bare stranded class B

concentric round (14-8 AWG)

APPLICATION

Power or control circuits in recognized

switchboard wiring

Dry locations 90deg C

presence of oil Also suitable as

designs

temperatures

4) Suitable for installation in sub-zero

pulling and greater conduit fill

5) Optical For CT use marking for use in

cable trays Sunlight resistant in

FEATURES

2) Good moisture resistance

raceways in wet or dry location and in

90deg CWet locationsOverload 130deg CShort Circuit

MAXIMUM OPERATING VOLTAGE

3) Good resistance to most oils and

chemicals

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

accordance with NEC Article 3186) Available in VW-1 and non VW-1

UL-44

SPECIFICATIONS

Chapter 9

250deg C

1) Smaller overall diameter for easier

HOW TO ORDER

National Electrical Code References

Article 310

VULCANELreg XLPE cable type XHHW-2600 volts size and length

Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL

TYPE XHHW-2 600 VOLTS

reg XLPE CABLE

2 1

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch Mils inch lbMft

manufacturing tolerances

14 7 41 007 30 013 19

12 7 65 009 30 015 48

10 7 103 011 30 017 42

8 7 165 015 45 024 71

6 7 262 018 45 027 98

4 7 417 023 45 032 153

2 7 663 029 45 038 241

10 19 1060 037 55 048 378

20 19 1330 041 55 052 446

30 19 1680 047 55 058 556

40 19 2110 052 55 063 697

250 37 057 65 070 851

300 37 062 65 075 997

350 37 067 65 080 1180

400 37 072 65 085 1306

500 37 080 65 093 1662

600 61 088 80 104 1974

750 61 098 80 115 2450

1000 61 114 80 130 3240

Dimension and weights shown are nominal unless otherwise indicated and subject to

13

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

APPLICATION

FEATURES

MAXIMUM OPERATING VOLTAGE

MAXIMUM CONDUCTOR TEMPERATURE

UL-44

SPECIFICATIONS

Chapter 9

HOW TO ORDER

National Electrical Code References

Article 310Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL S8000

XHHW or XHHW-2 600 VOLTS ALUMINUM

reg XLPE CABLE

manufacturing tolerances

Size Number Insulations Overall Netof Thickness Diameter Weight

AWGkcmilStrands Mils In LbMft

6 7 45 027 42

4 7 45 031 59

2 7 45 036 88

1 7 55 042 111

10 19 55 045 136

20 19 55 049 165

30 19 55 054 203

40 19 55 059 250

250 37 65 066 300

300 37 65 071 354

350 37 65 075 405

500 37 65 087 562

600 61 80 098 684

750 61 80 108 840

900 61 80 117 995

Dimension and weights shown are nominal unless otherwise indicated and subject to

2 13

1) Stranded compact class B AA-8000 series aluminum alloy soft conductor2) Separator tape3) Cross-linked polyethylene (XLPE) insulation type XHHW or XHHW-2

Branch-circuits and feeders conductors in low voltage for buildings schools auditoriums hospitals stadiums museums poultry farms etc Industrial and commercial buildings For use in cable trays or raceways in wet and dry locations

600 volts

Wet and dry continuousOverloadShort circuit

90 C130 C125 C

1) Easier pulling and greater conduit fill2) Good moisture resistance3) Excellent dielectrics properties4) Continuous 90 C operating temperature in wet or dry locations5) Suitable for use in cable trays (10 AWG and greater)6) VW-1 compliant7) Sunlight resistant insulatedRoHS compliant

APPROVALS

Type XHHW or XHHW-2 UL listedType Rw90 or RWU90 upon special request

Vulcanel S8000 cable type XHHW or XHHW-2 RoHS CT-SR with stranded compact class B AA-8000 series aluminum alloy soft conductor size length and product number

reg

114

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANEL EPR ANTILLAMA CABLE

600 VOLTS

26ACSR01

DESCRIPTION

FEATURES

HOW TO ORDER

SPECIFICATIONSSPECIFICATIONS

3 2 1

1) Annealed coated or un-coated stranded class B copper conductor2) Ethylene propylene rubber (EPR) insulation3) Chlorosulfonated polyethylene (Hypalon) or chlorinated polyethylene(CPE) jacket

APPLICATION

Ideally suited for use in Electrical generating stations May be installed in free air all raceways or direct burial

MAXIMUM CONDUCTOR TEMPERATUREDry LocationsDry and Wet LocationsOverloadShort Circuit

90 C75 C130 C250 C

MAXIMUM OPERATING VOLTAGE600 Volts

1) Flame resistant Meets or exceeds requirements of IEEE 383 flame test2) Deformation resistant at high temperatures3) Excellent Flexibility at low temperature suitable for installation in sub-zero temperatures4) Extra tough mechanically rugged composite insulation and jacket construction6) Resistant to most oils and chemicals

ICEA S-95-658

VULCANEL EPR ANTILLAMA cable 600 volts size length National Electrical Code ReferencesAmpacities Article 31318-10Cable Trays Article 318

Dupont trade mark

reg reg

Size Number Conductor Insulation Jacket Overall Netof Diameter Thickness Thickness Diameter Weight

AWGkcmilStrands Inch mils mils inch lbMft

8 7 015 45 15 026 79

6 7 118 45 30 042 125

4 7 023 45 30 038 179

2 7 029 45 30 043 269

10 19 037 55 45 056 432

20 19 041 55 45 061 528

30 19 047 55 45 066 647

40 19 052 55 45 071 797

250 37 057 65 45 082 982

300 37 062 65 65 087 1146

352 37 067 65 65 092 1351

400 37 072 65 65 097 1480

500 37 080 65 65 105 1782

600 61 088 80 65 116 2186

750 61 098 80 65 126 2685

1000 61 114 80 65 141 3410

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

reg reg

15

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

CODE SIZE STRAND OVERALL DIAMETER NET WEIGHT RUPTURE STRENGTH

Turkey 6 61 0198 503 36 54

Swan 4 61 0250 635 58 86

Swallow 3 61 0281 714 73 108

Sparrow 2 61 0316 803 91 136

Robin 1 61 0355 902 115 171

Raven 10 61 0398 1011 145 216

Quail 20 61 0447 1135 183 273

Pigeon 30 61 0502 1275 231 344

Penguin 40 61 0563 1430 291 433

Partridge 2668 267 0642 1631 366 544

Linnet 3364 267 0721 1831 162 688

Oriole 3364 307 0741 1882 525 782

Ibis 3975 267 0783 1989 545 811

Lark 3975 307 0806 2047 619 921

Hawk 4770 267 0858 2179 654 973

Hen 4770 307 0883 2243 743 1106

Heron 5000 307 0904 2296 781 1162

Dove 5565 267 0927 2355 765 1138

Eagle 5565 307 0953 2421 869 1293

Duck 6050 547 0953 2421 779 1159

Grosbeak 6360 267 0990 2515 872 1298

Starling 7155 267 1051 2670 986 1467

Crow 7155 547 1035 2629 918 1366

Drake 7950 267 1108 2814 1095 1629

Condor 7950 547 1093 2776 1021 1520

Canary 9000 547 1162 2951 1160 1726

Rail 9540 457 1165 2959 1076 1601

Bluejay 11130 457 1259 3198 1256 1869

11903

18608

23040

28575

35550

43875

53100

66825

84308

113175

141075

173250

163125

203175

195075

238500

247500

227250

279000

234000

252000

283500

261000

315000

281250

323370

258750

309870

WORD AWG or MCM ALSteel Inch mm Lbsmft kgkm lbs

manufacturing tolerances

Condumex can currently produce a wider

BARE ACSR CABLE

ALUMINUM CONDUCTOR STEEL REINFORCED

26ACSR01

DESCRIPTION

CONDUCTORS

Aluminum 1350 wire concentrically laid overa solid or stranded galvanized steel core

Mechanical design requirements5) Good corrosion resistance

3) High resistance to mechanical strength4) Wide variety of sizes available in long

lengths to suit both electrical and

fewer towers required

strength to permit the longest possiblespans

2) Minimum sag between supports with

1) Ideal combination of conductivity and

FEATURES

Code Word quantity required in weight

ACSR cable size Aluminum Association

HOW TO ORDER

Overhead transmission subtransmission

overhead electrical cables Messenger and

overhead lines Messenger cables to support

APPLICATION

and distribution systems Static wires to protect

power support conductor in catenary systems

for railroad electrification

SPECIFICATIONS

ASTM B498 Galvanized steel class A

ASTM B232 Conductor overall

SPECIFICATIONS

ASTM B230 Aluminum wires

MAXIMUM CONDUCTOR TEMPERATURE

Normal Operation 75 degC

116

Dimension and weights shown are nominal unless otherwise indicated and subject to

range of products then what is listedPlease contact us for other items

Grand Prairie Texas800-925-9473

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
Page 7: 5Power Cable Specs Set 2 - Condumex  · PDF fileCondumex Wire and Cable 2590 114th Street, ... Type Conductors Diameter Ampacity Weight AWG ... 6 19 26.2 0.18 30 6 0.26

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947311-10

THHNTHWN 600 VOLTS

POWER CABLE TYPE TC

DESCRIPTION

2) Polyvinyl Chloride (PVC) thermoplastic

insulation

1) Annealed bare Class C concentric

strand copper conductors

3) Nylon protective covering

4) Binder tape over core

5) Overall flame retardant PVC jacket

Dimension and weights shown are nominal unless otherwise indicated and subject to

Size Number Number Jacket Overall Netof of Thickness Diameter WeightAWG

Strands Conductors mils inches lbMft

2 45 034 68

3 45 036 87

4 45 040 109

14 19 5 45 043 130

7 45 046 167

9 60 056 234

12 60 063 285

16 60 067 335

2 45 038 90

3 45 040 119

4 45 043 154

5 45 046 173

12 19 7 60 055 247

9 60 064 326

12 60 071 400

16 60 076 485

2 45 045 139

3 45 047 180

4 60 055 247

10 19 5 60 060 178

7 60 065 367

9 60 075 480

12 80 089 637

manufacturing tolerances

FEATURES

Wet or DryDry

75deg C90deg C

APPLICATION

Electrical Code

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet ordry locations and in the presence of oil and most

lighting control signal and communcation circuitsin raceways direct burial in earth or in

SPECIFICATIONS

S-73-532 (table E-2 or Method SB 4)7) Circuit identification color coded per ICEA

UL 1277 UL 83 and ER Approved

HOW TO ORDER

chemicals in accordance with the National

MAXIMUM OPERATING VOLTAGE

600 volts

MAXIMUM CONDUCTOR TEMPERATURE

Condumex Tray Cable Type TCTHHN

600 volts number and size of conductors

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

BTU flame test3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

Electrical Code

tray cable used in accordance with the National

Resistant I

O5) PVC jacket is UL rated 90 C and listed Oil

required metallic sheathed cablessubstantial cost savings over the previouslyLocation Applications Type TX offers

6) Acceptable for Class I Division 2 Hazardous

7a) Other color coding methods are available based on ICEA S-73-532

4

245 13

8) ldquoERrdquo Listed per UL 1277

RoHS

5) Binder tape over core

750 kcmil) copper conductors

6) Overall flame retardant PVC jacket

DESCRIPTION

3) Nylon protective covering4) Fillers

1) Annealed bare Class C (8-2 AWG)compressed stranded Class B (10 AWG-

2) Polyvinyl Chloride thermoplastic insulation

36 145 2

POWER CABLE TYPE TC

THHNTHWN 600 VOLTS

Size Number Ground Insulation Jacket Overall Netof Conductor Thickness Thickness Diameter Weight

AWGkcmilConductors AWG mils mils inch lbMft

8 3 10 305 60 0638 338

6 3 8 305 60 0698 448

4 3 6 407 80 0884 693

2 3 6 407 80 1015 1012

1 3 8 507 80 1150 1210

10 3 6 508 80 1223 1495

20 3 6 508 80 1320 1858

30 3 4 508 80 1428 2297

40 3 4 508 80 1549 2791

250 3 4 609 80 1760 3374

350 3 3 609 110 1980 4526

500 3 2 609 110 2260 6230

750 3 1 7010 110 2967 8845

10 4 6 508 80 1350 1913

20 4 6 508 80 1457 2311

40 4 4 508 110 1773 3597

350 4 3 609 110 2188 5754

500 4 2 609 110 2502 8018

750 4 1 7010 140 3057 11716

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

MAXIMUM OPERATING VOLTAGE

UL 1277 UL 83 and ER Approved

7) Circuit identification color coded per ICEA

MAXIMUM CONDUCTOR TEMPERATURE

Wet or DryDry

75deg C90deg C

required metallic sheathed cables

3) Sunlight resistant can be installed outdoors

tray cable use in accordance with the National

Electrical Code

APPLICATION

in accordance with the National Electrical Code

6) Acceptable for Class I Division 2 Hazardous

4) UL listed as Type TC for power and control

600 volts

5) PVC jacket is UL rated 90deg C and listed Oil

Resistant I

1) UL listed for direct burial

2) Flame retardant (passes UL 1277 70000

BTU flame test)

FEATURES

Condumex Type TC cable may be used for

cable may be used in wet or dry locations and in the presence of oil and most chemicals

power lighting control signal and communication circuits in raceways direct

HOW TO ORDER

600 volts number and size of conductorsCondumex Tray Cable Type TCTHHN

SPECIFICATIONS

S-73-532 (table E-2 or Method SB 4)

Location Applications Type TC offers

substantial cost savings over the previously

7a) Other color coding methods are available based on ICEA S-73-532

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947303-06

5

8) ldquoERrdquo Listed per UL 1277

RoHS

1) Annealed bare stranded class B compact

copper conductor

DESCRIPTION

3) Ethylene propylene (EPR) or cross-linked

polyethylene (XLPE) insulation

4) Polyvinyl chloride (PVC) protective jacket

2) Extruded semiconducting strand shield

VULCANELreg MEDIUM VOLTAGE

WET OR DRY POWER CABLE 5 KVXLPE OR EPR NON-SHIELDED

24 13

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

Size Number Conductor Insulation Insulation Jacket OverallAWG of Diameter Thickness Diameter Thickness Diameterkcmil Strands inch inch inch mils Inch XLPE EPR

Net WeightLbMft

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

manufacturing tolerances

5kV 133 Insulation Level 115 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject to

cable voltage and insulation level conductor

Ampacities

Cable Trays

Type MV

ICEA S-66-524 AEIC CS-S (XLP)

extrusion) results in a virtually perfect cable core

- Very low dielectric loss

Normal Operation 105deg C130deg CEmergency Overload

VULCANELreg 5kv Non-shielded power cables

adequate for proper termination of the shielding

1) Simultaneous extrusion of strand shield

250deg CShort Circuit

UL 1072

326

318

310-15

National Electrical Code References

VULCANELreg EPRXLPE Non-Shielded power

size and type length and reel dimensions

SPECIFICATIONS

are ideally suited for use in industrial andutility applications where shields cannot be

APPLICATION

abrasion ozone and moisture

- Electrical stability under stress- Low dielectric loss- Chemical resistance

FEATURES

3) Easy-stripping insulation shield4) The external PVC jacket is resistant to

EPR insulation offers- Excellent heat moisture and corona

2) XLPE insulation offers- Low moisture absorption- Good resistance to chemicals

insulation and insulation shield (triple

accordance with the National ElectricalCode

5) UL listed as MV-105 sunlight resistantdirect burial Optional marking For CTuse available on single conductor in

HOW TO ORDER

resistance

MAXIMUM CONDUCTOR TEMPERATURE

Page 1 of 2

ICEA S-68-516 AEIC CS-6-87 (EPR)

6

RoHS

VULCANELreg MEDIUM VOLTAGE

WET OR DRY POWER CABLE 5 KVXLPE OR EPR NON-SHIELDED

Page 2 of 2

Size Number Conductor Insulation Insulation Jacket OverallAWG of Diameter Thickness Diameter Thickness Diameterkcmil Strands inch inch inch mils Inch XLPE EPR

Net WeightlbMft

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

25kV 100 Insulation Level 260 mils Insulation Thickness

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

35kV 100 Insulation Level 345 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

15kV 133 Insulation Level 220 mils Insulation Thickness

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

17

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANELreg MEDIUM VOLTAGE EPR

SHIELDED POWER CABLES 5 15 25 35 KV

346 125

DESCRIPTION

1) Annealed bare stranded class B compactcopper conductor

2) Extruded semiconducting strand shield3) Ethylene propylene rubber (EPR) insulation4) Extruded semiconducting insulation shield5) Annealed copper tape shield (25 overlap

6) Polyvinyl chloride (PVC) protective jacketminimum)

Three-phase electrical distribution systems

trays

Suitable for use in overhead installationsrecognized raceways direct burial or cable

APPLICATION

voltage and insulation level conductor

AmpacitiesCable TraysType MV

- Chemical resistance

5) The external PVC jacket is resistant to

- Electrical stability under stress

MAXIMUM CONDUCTOR TEMPERATURE

SPECIFICATIONS

use available on single conductor in

accordance with the National ElectricalCode

abrasion ozone and moisture6) UL listed as MV-105 sunlight resistant

direct burial Optional marking For CT

3) Easy-stripping insulation shield4) Tape shield provides high short circuit

capabilities and uniform shield impedance

- Low dielectric loss

UL 1072

size and type length and reel dimensions

ICEA S-68-516 AEIC CS6-87

326318310-15

National Electrical Code References

VULCANELreg EPR shielded power cable

2) EPR insulation offers- Excellent heat moisture and corona

resistance

insulation and insulation shield (tripleextrusion) results in a virtually perfect

cable core

250 degCShort Circuit

1) Simultaneous extrusion of strand shield

Normal Operation 105 degC130 degCEmergency Overload

FEATURES

SPECIFICATIONS

HOW TO ORDER

Page 1 of 2

Size Number Conductor Insulation Insul Shld Jacket Overall Netof Diameter Thickness Diameter Thickness Diameter Weight

AWGkcmilStrands Inch inch inch mils Inch lbMft

6 7 017 045 053 60 067 290

4 7 022 049 057 60 071 357

2 7 027 055 063 60 074 478

10 19 034 062 070 80 085 668

20 19 038 066 074 80 092 775

30 19 043 071 079 80 097 933

40 19 048 076 084 80 102 1071

250 37 052 081 090 80 107 1226

350 37 062 091 099 80 117 1560

500 37 074 103 113 80 132 2150

750 61 091 121 132 80 150 3027

1000 61 111 136 146 80 164 3845

5kV 133 Insulation Level 115 mils Insulation Thickness

2 7 027 067 075 80 093 570

10 19 034 074 082 80 100 736

20 19 038 078 086 80 104 849

30 19 043 083 091 80 109 1010

40 19 048 088 096 80 114 1190

250 37 052 094 102 80 120 1330

350 37 062 103 114 80 132 1753

500 37 074 116 126 80 144 2280

750 61 091 134 144 80 162 3142

1000 61 111 136 159 110 183 5794

5kV 100 Insulation Level 175 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

Page 2 of 2

VULCANELreg MEDIUM VOLTAGE EPR

SHIELDED POWER CABLES 5 15 25 35 KV

Size Number Conductor Insulation Insul Shld Jacket Overall Netof Diameter Thickness Diameter Thickness Diameter Weight

AWGkcmilStrands Inch inch inch mils Inch lbMft

6 7 017 045 053 60 067 290

4 7 022 049 057 60 071 357

2 7 027 055 063 60 074 478

10 19 034 062 070 80 085 668

20 19 038 066 074 80 092 775

30 19 043 071 079 80 097 933

40 19 048 076 084 80 102 1071

250 37 052 081 090 80 107 1226

350 37 062 091 099 80 117 1560

500 37 074 103 113 80 132 2150

750 61 091 121 132 80 150 3027

1000 61 111 136 146 80 164 3845

15kV 133 Insulation Level 220 mils Insulation Thickness

10 19 034 092 100 80 118 894

20 19 038 096 104 80 122 1009

30 19 043 100 111 80 129 1181

40 19 048 106 116 80 134 1394

250 37 052 111 122 80 140 1537

350 37 062 121 131 80 149 1936

500 37 074 133 143 80 161 2516

750 61 091 151 161 110 185 3620

1000 61 111 166 180 110 204 4543

25kV 100 Insulation Level 260 mils Insulation Thickness

10 19 034 109 119 80 137 1041

20 19 038 113 123 80 141 1226

30 19 043 118 128 80 146 1380

40 19 048 123 133 80 151 1569

250 37 052 129 139 80 157 1750

350 37 062 138 149 80 167 2163

500 37 074 150 161 110 185 2893

750 61 091 168 183 110 207 3900

1000 61 111 183 197 110 221 4807

35kV 100 Insulation Level 345 mils Insulation Thickness

manufacturing tolerancesDimension and weights shown are nominal unless otherwise indicated and subject to

19

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-94735-05

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

ICEA-S-68-516

SPECIFICATIONS

three conductor cable voltage size andlength

Condumex Mining Cable EPR type SHD-GC

HOW TO ORDER

MINING CABLE EPR TYPE SHD-GC

THREE CONDUCTOR 5000 VOLTS

18SHD-GC01

with a nylon webbing provides a tough defense

round configuration

and Health Administration Approval No P-218-1-MSHA

by the Pennsylvania Department of Environmental

Resources Meets MSHA flame test requirements

6) Acceptance No P-218-1-MSHA by Mines Safety

5) CV-Cured extra-heavy-duty CPE reinforced

4) Prevulcanized thermosetting non-wicking fillers

mechanical resistant jacket

resistance outstanding corona resistance

high dielectric strength and chemical resistance

designed for flexibility and resistance to

FEATURES

2) Ground check conductor facilitates fail-safe

3) EPR insulation offers excellent heat and moisture

are used if necessary to obtain a substantially

1) Special tinned copper stranded conductors

fatigue resulting from bending and flexing

ground monitoring for maximum safety

Dimension and weights shown are nominal unless otherwise indicated and subject to

6 7x3029 020 110 10 8 156

4 7x4729 025 110 8 8 168

2 7x7429 031 110 6 8 187

1 7x3725 035 110 5 8 195

10 7x4725 039 110 4 8 208

20 7x6025 045 110 3 8 220

30 7x7525 050 110 2 8 236

40 19x3525 059 110 1 8 250

300 19x4925 069 120 10 8 281

350 19x5825 076 120 20 8 295

1675

1888

2322

2653

3068

3504

4206

5023

6371

7654

Size Number of Conductor Insulation Ground Ground OverallAWG Strands Diameter Thickness Size Check Size Diameterkcmil AWG inch mils AWG AWG inch

NetWeightlbmft

manufacturing tolerances

MAXIMUM CONDUCTOR TEMPERATURE

Normal continuous 90deg C130deg COverload

250deg CShort circuit

MAXIMUM OPERATING VOLTAGE

5000 volts

Trailing cable on ac mining equipment

where service conditions are severe andmaximum safety is mandatory such as

APPLICATION

power shovels and draglines in open-pit

mines quarries gantry cranes and slag

reclaiming Also used for medium voltage

distribution in underground mines where

frequent relocation is necessary

DESCRIPTION

1) Three flexible annealed tinned copper rope-lay stranded conductors

2) Extruded semi-conducting conductor shieldand ethylene propylene rubber (EPR) insulation

3) Color coded cottoncopper braid shield applied over semi-conducting tape

4) Two annealed tinned copper rope-lay strandedgrounding conductors

5) Annealed tinned copper rope-lay stranded

and covered with a yellow cotton braid

chlorinated polyethylene (CPE) jacket

6) Rubberized cotton binder tape7) Nylon web reinforced extra-heavy-duty

ground check conductor yellow EPR insulation

346 2 157

110

RoHS

5) Overall flame retardant PVC jacket

DESCRIPTION

XLP insulation3) Fillers (if required)

4) Binder tape over core

2) Cross-Linked polyethylene thermosetting

1) Annealed bare stranded compressed

Class B copper conductors

without grounding conductorVolts number and size of conductors with or

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet

lighting control signal and communication circuitsin cable trays raceways direct burial or on

HOW TO ORDER

Condumex Tray Cable Type TCXHHW 600

SPECIFICATIONS

UL-1277 amp UL-44

APPLICATION

most chemicals in accordance with the

MAXIMUM OPERATING VOLTAGE

National Electrical Code

or dry locations and in the presence of oil and

6) Acceptable for Class 1 Division 2 HazardousLocations applications

O5) PVC jacket is UL rated 90 C and listed OilResistant I

600 volts

MAXIMUM CONDUCTOR TEMPERATUREO 90 C

O130 C

FEATURES

OverloadNormal

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

National Electrical Code

BTU flame test)3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

tray cable use in accordance with the

3 145 2

POWER CABLE TYPE TC

XHHW 600 VOLTS

Size Number Ground Insulation Jacket Overall Netof Conductor Thickness Thickness Diameter Weight

AWGkcmilConductors AWG mils mils inch lbMft

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 3 10 45 60 066 310

6 3 8 45 60 074 448

4 3 8 45 80 088 659

2 3 6 45 80 103 968

10 3 6 55 80 121 1428

20 3 4 55 80 131 1735

30 3 4 55 80 142 2150

40 3 4 55 80 154 3620

250 3 4 65 110 175 3190

350 3 3 65 110 196 4305

500 3 2 65 110 225 5940

8 4 10 45 60 073 385

6 4 8 45 80 083 568

4 4 8 45 80 097 832

2 4 6 45 80 112 1230

10 4 6 5 80 134 1825

20 4 4 55 80 145 2212

30 4 4 55 80 157 2751

40 4 4 55 110 177 3462

250 4 4 65 110 198 4097

350 4 3 65 110 217 5542

500 4 2 65 110 249 7690

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

111

7) ldquoERrdquo Listed per UL 1277

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

National Electrical Code References

Product Article 310 Table 310-13

Ampacities Article 310-15

HOW TO ORDER

CONDUMEX type RHH-RHW-USE-2

XLPE 600 volts size length quantity

packaging

DESCRIPTION

polyethylene (XLPE) insualtion

1) Annealed bare stranded class B

conductor

2) Flame-retardant cross-linked

TYPE RHH-RHW-USE-2

COPPER XLPE 600 VOLTS

APPLICATION

May be installed in free air all raceways or

underground service entrance cable

Type RHH 90deg C Dry and

temperatures

6) Stable electrical propoerties

UL-44 Standard for Rubber-Insulated

use in direct burial in industrial andcommercial application May be used as

7) Extremely tough

SPECIFICATIONS

4) Good resistance to most oils and

3) UL approved as VW-1 (RHH or RHW)

chemicals5) Suitable for installation in sub-zero

2) UL listed as types RHH or RHW or USE forresistant insulation

damp locations

ICEA S-66-524 Standard for Cross-Linked

Type RHW or 75deg C Dry and

use in accordance with the National

Electrical Code

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

MAXIMUM OPERATING VOLTAGE

USE wet locatinons

1) Flame retardant moisture and heat

FEATURES

Wires and Cables

Polyethylene Insualted Wire and Cable

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch mils inch lbMft

8 7 165 015 60 027 73

6 7 262 018 60 031 108

4 7 417 022 60 035 161

2 7 663 028 60 041 245

10 19 106 036 80 053 392

20 19 133 041 80 058 485

30 19 168 046 80 063 600

40 19 211 051 80 069 746

250 37 056 95 076 887

300 37 061 95 082 1052

350 37 066 95 087 1216

400 37 071 95 092 1380

500 37 079 95 099 1708

600 61 087 110 111 2055

750 61 097 110 120 2542

1000 61 112 110 136 3353

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

11 112

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

copper conductor

2) Cross-linked polyethylene (XLPE)

insulation

compressed (6 AWG-1000 MCM)

1) Annealed bare stranded class B

concentric round (14-8 AWG)

APPLICATION

Power or control circuits in recognized

switchboard wiring

Dry locations 90deg C

presence of oil Also suitable as

designs

temperatures

4) Suitable for installation in sub-zero

pulling and greater conduit fill

5) Optical For CT use marking for use in

cable trays Sunlight resistant in

FEATURES

2) Good moisture resistance

raceways in wet or dry location and in

90deg CWet locationsOverload 130deg CShort Circuit

MAXIMUM OPERATING VOLTAGE

3) Good resistance to most oils and

chemicals

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

accordance with NEC Article 3186) Available in VW-1 and non VW-1

UL-44

SPECIFICATIONS

Chapter 9

250deg C

1) Smaller overall diameter for easier

HOW TO ORDER

National Electrical Code References

Article 310

VULCANELreg XLPE cable type XHHW-2600 volts size and length

Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL

TYPE XHHW-2 600 VOLTS

reg XLPE CABLE

2 1

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch Mils inch lbMft

manufacturing tolerances

14 7 41 007 30 013 19

12 7 65 009 30 015 48

10 7 103 011 30 017 42

8 7 165 015 45 024 71

6 7 262 018 45 027 98

4 7 417 023 45 032 153

2 7 663 029 45 038 241

10 19 1060 037 55 048 378

20 19 1330 041 55 052 446

30 19 1680 047 55 058 556

40 19 2110 052 55 063 697

250 37 057 65 070 851

300 37 062 65 075 997

350 37 067 65 080 1180

400 37 072 65 085 1306

500 37 080 65 093 1662

600 61 088 80 104 1974

750 61 098 80 115 2450

1000 61 114 80 130 3240

Dimension and weights shown are nominal unless otherwise indicated and subject to

13

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

APPLICATION

FEATURES

MAXIMUM OPERATING VOLTAGE

MAXIMUM CONDUCTOR TEMPERATURE

UL-44

SPECIFICATIONS

Chapter 9

HOW TO ORDER

National Electrical Code References

Article 310Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL S8000

XHHW or XHHW-2 600 VOLTS ALUMINUM

reg XLPE CABLE

manufacturing tolerances

Size Number Insulations Overall Netof Thickness Diameter Weight

AWGkcmilStrands Mils In LbMft

6 7 45 027 42

4 7 45 031 59

2 7 45 036 88

1 7 55 042 111

10 19 55 045 136

20 19 55 049 165

30 19 55 054 203

40 19 55 059 250

250 37 65 066 300

300 37 65 071 354

350 37 65 075 405

500 37 65 087 562

600 61 80 098 684

750 61 80 108 840

900 61 80 117 995

Dimension and weights shown are nominal unless otherwise indicated and subject to

2 13

1) Stranded compact class B AA-8000 series aluminum alloy soft conductor2) Separator tape3) Cross-linked polyethylene (XLPE) insulation type XHHW or XHHW-2

Branch-circuits and feeders conductors in low voltage for buildings schools auditoriums hospitals stadiums museums poultry farms etc Industrial and commercial buildings For use in cable trays or raceways in wet and dry locations

600 volts

Wet and dry continuousOverloadShort circuit

90 C130 C125 C

1) Easier pulling and greater conduit fill2) Good moisture resistance3) Excellent dielectrics properties4) Continuous 90 C operating temperature in wet or dry locations5) Suitable for use in cable trays (10 AWG and greater)6) VW-1 compliant7) Sunlight resistant insulatedRoHS compliant

APPROVALS

Type XHHW or XHHW-2 UL listedType Rw90 or RWU90 upon special request

Vulcanel S8000 cable type XHHW or XHHW-2 RoHS CT-SR with stranded compact class B AA-8000 series aluminum alloy soft conductor size length and product number

reg

114

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANEL EPR ANTILLAMA CABLE

600 VOLTS

26ACSR01

DESCRIPTION

FEATURES

HOW TO ORDER

SPECIFICATIONSSPECIFICATIONS

3 2 1

1) Annealed coated or un-coated stranded class B copper conductor2) Ethylene propylene rubber (EPR) insulation3) Chlorosulfonated polyethylene (Hypalon) or chlorinated polyethylene(CPE) jacket

APPLICATION

Ideally suited for use in Electrical generating stations May be installed in free air all raceways or direct burial

MAXIMUM CONDUCTOR TEMPERATUREDry LocationsDry and Wet LocationsOverloadShort Circuit

90 C75 C130 C250 C

MAXIMUM OPERATING VOLTAGE600 Volts

1) Flame resistant Meets or exceeds requirements of IEEE 383 flame test2) Deformation resistant at high temperatures3) Excellent Flexibility at low temperature suitable for installation in sub-zero temperatures4) Extra tough mechanically rugged composite insulation and jacket construction6) Resistant to most oils and chemicals

ICEA S-95-658

VULCANEL EPR ANTILLAMA cable 600 volts size length National Electrical Code ReferencesAmpacities Article 31318-10Cable Trays Article 318

Dupont trade mark

reg reg

Size Number Conductor Insulation Jacket Overall Netof Diameter Thickness Thickness Diameter Weight

AWGkcmilStrands Inch mils mils inch lbMft

8 7 015 45 15 026 79

6 7 118 45 30 042 125

4 7 023 45 30 038 179

2 7 029 45 30 043 269

10 19 037 55 45 056 432

20 19 041 55 45 061 528

30 19 047 55 45 066 647

40 19 052 55 45 071 797

250 37 057 65 45 082 982

300 37 062 65 65 087 1146

352 37 067 65 65 092 1351

400 37 072 65 65 097 1480

500 37 080 65 65 105 1782

600 61 088 80 65 116 2186

750 61 098 80 65 126 2685

1000 61 114 80 65 141 3410

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

reg reg

15

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

CODE SIZE STRAND OVERALL DIAMETER NET WEIGHT RUPTURE STRENGTH

Turkey 6 61 0198 503 36 54

Swan 4 61 0250 635 58 86

Swallow 3 61 0281 714 73 108

Sparrow 2 61 0316 803 91 136

Robin 1 61 0355 902 115 171

Raven 10 61 0398 1011 145 216

Quail 20 61 0447 1135 183 273

Pigeon 30 61 0502 1275 231 344

Penguin 40 61 0563 1430 291 433

Partridge 2668 267 0642 1631 366 544

Linnet 3364 267 0721 1831 162 688

Oriole 3364 307 0741 1882 525 782

Ibis 3975 267 0783 1989 545 811

Lark 3975 307 0806 2047 619 921

Hawk 4770 267 0858 2179 654 973

Hen 4770 307 0883 2243 743 1106

Heron 5000 307 0904 2296 781 1162

Dove 5565 267 0927 2355 765 1138

Eagle 5565 307 0953 2421 869 1293

Duck 6050 547 0953 2421 779 1159

Grosbeak 6360 267 0990 2515 872 1298

Starling 7155 267 1051 2670 986 1467

Crow 7155 547 1035 2629 918 1366

Drake 7950 267 1108 2814 1095 1629

Condor 7950 547 1093 2776 1021 1520

Canary 9000 547 1162 2951 1160 1726

Rail 9540 457 1165 2959 1076 1601

Bluejay 11130 457 1259 3198 1256 1869

11903

18608

23040

28575

35550

43875

53100

66825

84308

113175

141075

173250

163125

203175

195075

238500

247500

227250

279000

234000

252000

283500

261000

315000

281250

323370

258750

309870

WORD AWG or MCM ALSteel Inch mm Lbsmft kgkm lbs

manufacturing tolerances

Condumex can currently produce a wider

BARE ACSR CABLE

ALUMINUM CONDUCTOR STEEL REINFORCED

26ACSR01

DESCRIPTION

CONDUCTORS

Aluminum 1350 wire concentrically laid overa solid or stranded galvanized steel core

Mechanical design requirements5) Good corrosion resistance

3) High resistance to mechanical strength4) Wide variety of sizes available in long

lengths to suit both electrical and

fewer towers required

strength to permit the longest possiblespans

2) Minimum sag between supports with

1) Ideal combination of conductivity and

FEATURES

Code Word quantity required in weight

ACSR cable size Aluminum Association

HOW TO ORDER

Overhead transmission subtransmission

overhead electrical cables Messenger and

overhead lines Messenger cables to support

APPLICATION

and distribution systems Static wires to protect

power support conductor in catenary systems

for railroad electrification

SPECIFICATIONS

ASTM B498 Galvanized steel class A

ASTM B232 Conductor overall

SPECIFICATIONS

ASTM B230 Aluminum wires

MAXIMUM CONDUCTOR TEMPERATURE

Normal Operation 75 degC

116

Dimension and weights shown are nominal unless otherwise indicated and subject to

range of products then what is listedPlease contact us for other items

Grand Prairie Texas800-925-9473

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
Page 8: 5Power Cable Specs Set 2 - Condumex  · PDF fileCondumex Wire and Cable 2590 114th Street, ... Type Conductors Diameter Ampacity Weight AWG ... 6 19 26.2 0.18 30 6 0.26

5) Binder tape over core

750 kcmil) copper conductors

6) Overall flame retardant PVC jacket

DESCRIPTION

3) Nylon protective covering4) Fillers

1) Annealed bare Class C (8-2 AWG)compressed stranded Class B (10 AWG-

2) Polyvinyl Chloride thermoplastic insulation

36 145 2

POWER CABLE TYPE TC

THHNTHWN 600 VOLTS

Size Number Ground Insulation Jacket Overall Netof Conductor Thickness Thickness Diameter Weight

AWGkcmilConductors AWG mils mils inch lbMft

8 3 10 305 60 0638 338

6 3 8 305 60 0698 448

4 3 6 407 80 0884 693

2 3 6 407 80 1015 1012

1 3 8 507 80 1150 1210

10 3 6 508 80 1223 1495

20 3 6 508 80 1320 1858

30 3 4 508 80 1428 2297

40 3 4 508 80 1549 2791

250 3 4 609 80 1760 3374

350 3 3 609 110 1980 4526

500 3 2 609 110 2260 6230

750 3 1 7010 110 2967 8845

10 4 6 508 80 1350 1913

20 4 6 508 80 1457 2311

40 4 4 508 110 1773 3597

350 4 3 609 110 2188 5754

500 4 2 609 110 2502 8018

750 4 1 7010 140 3057 11716

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

MAXIMUM OPERATING VOLTAGE

UL 1277 UL 83 and ER Approved

7) Circuit identification color coded per ICEA

MAXIMUM CONDUCTOR TEMPERATURE

Wet or DryDry

75deg C90deg C

required metallic sheathed cables

3) Sunlight resistant can be installed outdoors

tray cable use in accordance with the National

Electrical Code

APPLICATION

in accordance with the National Electrical Code

6) Acceptable for Class I Division 2 Hazardous

4) UL listed as Type TC for power and control

600 volts

5) PVC jacket is UL rated 90deg C and listed Oil

Resistant I

1) UL listed for direct burial

2) Flame retardant (passes UL 1277 70000

BTU flame test)

FEATURES

Condumex Type TC cable may be used for

cable may be used in wet or dry locations and in the presence of oil and most chemicals

power lighting control signal and communication circuits in raceways direct

HOW TO ORDER

600 volts number and size of conductorsCondumex Tray Cable Type TCTHHN

SPECIFICATIONS

S-73-532 (table E-2 or Method SB 4)

Location Applications Type TC offers

substantial cost savings over the previously

7a) Other color coding methods are available based on ICEA S-73-532

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947303-06

5

8) ldquoERrdquo Listed per UL 1277

RoHS

1) Annealed bare stranded class B compact

copper conductor

DESCRIPTION

3) Ethylene propylene (EPR) or cross-linked

polyethylene (XLPE) insulation

4) Polyvinyl chloride (PVC) protective jacket

2) Extruded semiconducting strand shield

VULCANELreg MEDIUM VOLTAGE

WET OR DRY POWER CABLE 5 KVXLPE OR EPR NON-SHIELDED

24 13

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

Size Number Conductor Insulation Insulation Jacket OverallAWG of Diameter Thickness Diameter Thickness Diameterkcmil Strands inch inch inch mils Inch XLPE EPR

Net WeightLbMft

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

manufacturing tolerances

5kV 133 Insulation Level 115 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject to

cable voltage and insulation level conductor

Ampacities

Cable Trays

Type MV

ICEA S-66-524 AEIC CS-S (XLP)

extrusion) results in a virtually perfect cable core

- Very low dielectric loss

Normal Operation 105deg C130deg CEmergency Overload

VULCANELreg 5kv Non-shielded power cables

adequate for proper termination of the shielding

1) Simultaneous extrusion of strand shield

250deg CShort Circuit

UL 1072

326

318

310-15

National Electrical Code References

VULCANELreg EPRXLPE Non-Shielded power

size and type length and reel dimensions

SPECIFICATIONS

are ideally suited for use in industrial andutility applications where shields cannot be

APPLICATION

abrasion ozone and moisture

- Electrical stability under stress- Low dielectric loss- Chemical resistance

FEATURES

3) Easy-stripping insulation shield4) The external PVC jacket is resistant to

EPR insulation offers- Excellent heat moisture and corona

2) XLPE insulation offers- Low moisture absorption- Good resistance to chemicals

insulation and insulation shield (triple

accordance with the National ElectricalCode

5) UL listed as MV-105 sunlight resistantdirect burial Optional marking For CTuse available on single conductor in

HOW TO ORDER

resistance

MAXIMUM CONDUCTOR TEMPERATURE

Page 1 of 2

ICEA S-68-516 AEIC CS-6-87 (EPR)

6

RoHS

VULCANELreg MEDIUM VOLTAGE

WET OR DRY POWER CABLE 5 KVXLPE OR EPR NON-SHIELDED

Page 2 of 2

Size Number Conductor Insulation Insulation Jacket OverallAWG of Diameter Thickness Diameter Thickness Diameterkcmil Strands inch inch inch mils Inch XLPE EPR

Net WeightlbMft

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

25kV 100 Insulation Level 260 mils Insulation Thickness

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

35kV 100 Insulation Level 345 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

15kV 133 Insulation Level 220 mils Insulation Thickness

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

17

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANELreg MEDIUM VOLTAGE EPR

SHIELDED POWER CABLES 5 15 25 35 KV

346 125

DESCRIPTION

1) Annealed bare stranded class B compactcopper conductor

2) Extruded semiconducting strand shield3) Ethylene propylene rubber (EPR) insulation4) Extruded semiconducting insulation shield5) Annealed copper tape shield (25 overlap

6) Polyvinyl chloride (PVC) protective jacketminimum)

Three-phase electrical distribution systems

trays

Suitable for use in overhead installationsrecognized raceways direct burial or cable

APPLICATION

voltage and insulation level conductor

AmpacitiesCable TraysType MV

- Chemical resistance

5) The external PVC jacket is resistant to

- Electrical stability under stress

MAXIMUM CONDUCTOR TEMPERATURE

SPECIFICATIONS

use available on single conductor in

accordance with the National ElectricalCode

abrasion ozone and moisture6) UL listed as MV-105 sunlight resistant

direct burial Optional marking For CT

3) Easy-stripping insulation shield4) Tape shield provides high short circuit

capabilities and uniform shield impedance

- Low dielectric loss

UL 1072

size and type length and reel dimensions

ICEA S-68-516 AEIC CS6-87

326318310-15

National Electrical Code References

VULCANELreg EPR shielded power cable

2) EPR insulation offers- Excellent heat moisture and corona

resistance

insulation and insulation shield (tripleextrusion) results in a virtually perfect

cable core

250 degCShort Circuit

1) Simultaneous extrusion of strand shield

Normal Operation 105 degC130 degCEmergency Overload

FEATURES

SPECIFICATIONS

HOW TO ORDER

Page 1 of 2

Size Number Conductor Insulation Insul Shld Jacket Overall Netof Diameter Thickness Diameter Thickness Diameter Weight

AWGkcmilStrands Inch inch inch mils Inch lbMft

6 7 017 045 053 60 067 290

4 7 022 049 057 60 071 357

2 7 027 055 063 60 074 478

10 19 034 062 070 80 085 668

20 19 038 066 074 80 092 775

30 19 043 071 079 80 097 933

40 19 048 076 084 80 102 1071

250 37 052 081 090 80 107 1226

350 37 062 091 099 80 117 1560

500 37 074 103 113 80 132 2150

750 61 091 121 132 80 150 3027

1000 61 111 136 146 80 164 3845

5kV 133 Insulation Level 115 mils Insulation Thickness

2 7 027 067 075 80 093 570

10 19 034 074 082 80 100 736

20 19 038 078 086 80 104 849

30 19 043 083 091 80 109 1010

40 19 048 088 096 80 114 1190

250 37 052 094 102 80 120 1330

350 37 062 103 114 80 132 1753

500 37 074 116 126 80 144 2280

750 61 091 134 144 80 162 3142

1000 61 111 136 159 110 183 5794

5kV 100 Insulation Level 175 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

Page 2 of 2

VULCANELreg MEDIUM VOLTAGE EPR

SHIELDED POWER CABLES 5 15 25 35 KV

Size Number Conductor Insulation Insul Shld Jacket Overall Netof Diameter Thickness Diameter Thickness Diameter Weight

AWGkcmilStrands Inch inch inch mils Inch lbMft

6 7 017 045 053 60 067 290

4 7 022 049 057 60 071 357

2 7 027 055 063 60 074 478

10 19 034 062 070 80 085 668

20 19 038 066 074 80 092 775

30 19 043 071 079 80 097 933

40 19 048 076 084 80 102 1071

250 37 052 081 090 80 107 1226

350 37 062 091 099 80 117 1560

500 37 074 103 113 80 132 2150

750 61 091 121 132 80 150 3027

1000 61 111 136 146 80 164 3845

15kV 133 Insulation Level 220 mils Insulation Thickness

10 19 034 092 100 80 118 894

20 19 038 096 104 80 122 1009

30 19 043 100 111 80 129 1181

40 19 048 106 116 80 134 1394

250 37 052 111 122 80 140 1537

350 37 062 121 131 80 149 1936

500 37 074 133 143 80 161 2516

750 61 091 151 161 110 185 3620

1000 61 111 166 180 110 204 4543

25kV 100 Insulation Level 260 mils Insulation Thickness

10 19 034 109 119 80 137 1041

20 19 038 113 123 80 141 1226

30 19 043 118 128 80 146 1380

40 19 048 123 133 80 151 1569

250 37 052 129 139 80 157 1750

350 37 062 138 149 80 167 2163

500 37 074 150 161 110 185 2893

750 61 091 168 183 110 207 3900

1000 61 111 183 197 110 221 4807

35kV 100 Insulation Level 345 mils Insulation Thickness

manufacturing tolerancesDimension and weights shown are nominal unless otherwise indicated and subject to

19

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-94735-05

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

ICEA-S-68-516

SPECIFICATIONS

three conductor cable voltage size andlength

Condumex Mining Cable EPR type SHD-GC

HOW TO ORDER

MINING CABLE EPR TYPE SHD-GC

THREE CONDUCTOR 5000 VOLTS

18SHD-GC01

with a nylon webbing provides a tough defense

round configuration

and Health Administration Approval No P-218-1-MSHA

by the Pennsylvania Department of Environmental

Resources Meets MSHA flame test requirements

6) Acceptance No P-218-1-MSHA by Mines Safety

5) CV-Cured extra-heavy-duty CPE reinforced

4) Prevulcanized thermosetting non-wicking fillers

mechanical resistant jacket

resistance outstanding corona resistance

high dielectric strength and chemical resistance

designed for flexibility and resistance to

FEATURES

2) Ground check conductor facilitates fail-safe

3) EPR insulation offers excellent heat and moisture

are used if necessary to obtain a substantially

1) Special tinned copper stranded conductors

fatigue resulting from bending and flexing

ground monitoring for maximum safety

Dimension and weights shown are nominal unless otherwise indicated and subject to

6 7x3029 020 110 10 8 156

4 7x4729 025 110 8 8 168

2 7x7429 031 110 6 8 187

1 7x3725 035 110 5 8 195

10 7x4725 039 110 4 8 208

20 7x6025 045 110 3 8 220

30 7x7525 050 110 2 8 236

40 19x3525 059 110 1 8 250

300 19x4925 069 120 10 8 281

350 19x5825 076 120 20 8 295

1675

1888

2322

2653

3068

3504

4206

5023

6371

7654

Size Number of Conductor Insulation Ground Ground OverallAWG Strands Diameter Thickness Size Check Size Diameterkcmil AWG inch mils AWG AWG inch

NetWeightlbmft

manufacturing tolerances

MAXIMUM CONDUCTOR TEMPERATURE

Normal continuous 90deg C130deg COverload

250deg CShort circuit

MAXIMUM OPERATING VOLTAGE

5000 volts

Trailing cable on ac mining equipment

where service conditions are severe andmaximum safety is mandatory such as

APPLICATION

power shovels and draglines in open-pit

mines quarries gantry cranes and slag

reclaiming Also used for medium voltage

distribution in underground mines where

frequent relocation is necessary

DESCRIPTION

1) Three flexible annealed tinned copper rope-lay stranded conductors

2) Extruded semi-conducting conductor shieldand ethylene propylene rubber (EPR) insulation

3) Color coded cottoncopper braid shield applied over semi-conducting tape

4) Two annealed tinned copper rope-lay strandedgrounding conductors

5) Annealed tinned copper rope-lay stranded

and covered with a yellow cotton braid

chlorinated polyethylene (CPE) jacket

6) Rubberized cotton binder tape7) Nylon web reinforced extra-heavy-duty

ground check conductor yellow EPR insulation

346 2 157

110

RoHS

5) Overall flame retardant PVC jacket

DESCRIPTION

XLP insulation3) Fillers (if required)

4) Binder tape over core

2) Cross-Linked polyethylene thermosetting

1) Annealed bare stranded compressed

Class B copper conductors

without grounding conductorVolts number and size of conductors with or

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet

lighting control signal and communication circuitsin cable trays raceways direct burial or on

HOW TO ORDER

Condumex Tray Cable Type TCXHHW 600

SPECIFICATIONS

UL-1277 amp UL-44

APPLICATION

most chemicals in accordance with the

MAXIMUM OPERATING VOLTAGE

National Electrical Code

or dry locations and in the presence of oil and

6) Acceptable for Class 1 Division 2 HazardousLocations applications

O5) PVC jacket is UL rated 90 C and listed OilResistant I

600 volts

MAXIMUM CONDUCTOR TEMPERATUREO 90 C

O130 C

FEATURES

OverloadNormal

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

National Electrical Code

BTU flame test)3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

tray cable use in accordance with the

3 145 2

POWER CABLE TYPE TC

XHHW 600 VOLTS

Size Number Ground Insulation Jacket Overall Netof Conductor Thickness Thickness Diameter Weight

AWGkcmilConductors AWG mils mils inch lbMft

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 3 10 45 60 066 310

6 3 8 45 60 074 448

4 3 8 45 80 088 659

2 3 6 45 80 103 968

10 3 6 55 80 121 1428

20 3 4 55 80 131 1735

30 3 4 55 80 142 2150

40 3 4 55 80 154 3620

250 3 4 65 110 175 3190

350 3 3 65 110 196 4305

500 3 2 65 110 225 5940

8 4 10 45 60 073 385

6 4 8 45 80 083 568

4 4 8 45 80 097 832

2 4 6 45 80 112 1230

10 4 6 5 80 134 1825

20 4 4 55 80 145 2212

30 4 4 55 80 157 2751

40 4 4 55 110 177 3462

250 4 4 65 110 198 4097

350 4 3 65 110 217 5542

500 4 2 65 110 249 7690

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

111

7) ldquoERrdquo Listed per UL 1277

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

National Electrical Code References

Product Article 310 Table 310-13

Ampacities Article 310-15

HOW TO ORDER

CONDUMEX type RHH-RHW-USE-2

XLPE 600 volts size length quantity

packaging

DESCRIPTION

polyethylene (XLPE) insualtion

1) Annealed bare stranded class B

conductor

2) Flame-retardant cross-linked

TYPE RHH-RHW-USE-2

COPPER XLPE 600 VOLTS

APPLICATION

May be installed in free air all raceways or

underground service entrance cable

Type RHH 90deg C Dry and

temperatures

6) Stable electrical propoerties

UL-44 Standard for Rubber-Insulated

use in direct burial in industrial andcommercial application May be used as

7) Extremely tough

SPECIFICATIONS

4) Good resistance to most oils and

3) UL approved as VW-1 (RHH or RHW)

chemicals5) Suitable for installation in sub-zero

2) UL listed as types RHH or RHW or USE forresistant insulation

damp locations

ICEA S-66-524 Standard for Cross-Linked

Type RHW or 75deg C Dry and

use in accordance with the National

Electrical Code

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

MAXIMUM OPERATING VOLTAGE

USE wet locatinons

1) Flame retardant moisture and heat

FEATURES

Wires and Cables

Polyethylene Insualted Wire and Cable

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch mils inch lbMft

8 7 165 015 60 027 73

6 7 262 018 60 031 108

4 7 417 022 60 035 161

2 7 663 028 60 041 245

10 19 106 036 80 053 392

20 19 133 041 80 058 485

30 19 168 046 80 063 600

40 19 211 051 80 069 746

250 37 056 95 076 887

300 37 061 95 082 1052

350 37 066 95 087 1216

400 37 071 95 092 1380

500 37 079 95 099 1708

600 61 087 110 111 2055

750 61 097 110 120 2542

1000 61 112 110 136 3353

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

11 112

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

copper conductor

2) Cross-linked polyethylene (XLPE)

insulation

compressed (6 AWG-1000 MCM)

1) Annealed bare stranded class B

concentric round (14-8 AWG)

APPLICATION

Power or control circuits in recognized

switchboard wiring

Dry locations 90deg C

presence of oil Also suitable as

designs

temperatures

4) Suitable for installation in sub-zero

pulling and greater conduit fill

5) Optical For CT use marking for use in

cable trays Sunlight resistant in

FEATURES

2) Good moisture resistance

raceways in wet or dry location and in

90deg CWet locationsOverload 130deg CShort Circuit

MAXIMUM OPERATING VOLTAGE

3) Good resistance to most oils and

chemicals

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

accordance with NEC Article 3186) Available in VW-1 and non VW-1

UL-44

SPECIFICATIONS

Chapter 9

250deg C

1) Smaller overall diameter for easier

HOW TO ORDER

National Electrical Code References

Article 310

VULCANELreg XLPE cable type XHHW-2600 volts size and length

Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL

TYPE XHHW-2 600 VOLTS

reg XLPE CABLE

2 1

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch Mils inch lbMft

manufacturing tolerances

14 7 41 007 30 013 19

12 7 65 009 30 015 48

10 7 103 011 30 017 42

8 7 165 015 45 024 71

6 7 262 018 45 027 98

4 7 417 023 45 032 153

2 7 663 029 45 038 241

10 19 1060 037 55 048 378

20 19 1330 041 55 052 446

30 19 1680 047 55 058 556

40 19 2110 052 55 063 697

250 37 057 65 070 851

300 37 062 65 075 997

350 37 067 65 080 1180

400 37 072 65 085 1306

500 37 080 65 093 1662

600 61 088 80 104 1974

750 61 098 80 115 2450

1000 61 114 80 130 3240

Dimension and weights shown are nominal unless otherwise indicated and subject to

13

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

APPLICATION

FEATURES

MAXIMUM OPERATING VOLTAGE

MAXIMUM CONDUCTOR TEMPERATURE

UL-44

SPECIFICATIONS

Chapter 9

HOW TO ORDER

National Electrical Code References

Article 310Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL S8000

XHHW or XHHW-2 600 VOLTS ALUMINUM

reg XLPE CABLE

manufacturing tolerances

Size Number Insulations Overall Netof Thickness Diameter Weight

AWGkcmilStrands Mils In LbMft

6 7 45 027 42

4 7 45 031 59

2 7 45 036 88

1 7 55 042 111

10 19 55 045 136

20 19 55 049 165

30 19 55 054 203

40 19 55 059 250

250 37 65 066 300

300 37 65 071 354

350 37 65 075 405

500 37 65 087 562

600 61 80 098 684

750 61 80 108 840

900 61 80 117 995

Dimension and weights shown are nominal unless otherwise indicated and subject to

2 13

1) Stranded compact class B AA-8000 series aluminum alloy soft conductor2) Separator tape3) Cross-linked polyethylene (XLPE) insulation type XHHW or XHHW-2

Branch-circuits and feeders conductors in low voltage for buildings schools auditoriums hospitals stadiums museums poultry farms etc Industrial and commercial buildings For use in cable trays or raceways in wet and dry locations

600 volts

Wet and dry continuousOverloadShort circuit

90 C130 C125 C

1) Easier pulling and greater conduit fill2) Good moisture resistance3) Excellent dielectrics properties4) Continuous 90 C operating temperature in wet or dry locations5) Suitable for use in cable trays (10 AWG and greater)6) VW-1 compliant7) Sunlight resistant insulatedRoHS compliant

APPROVALS

Type XHHW or XHHW-2 UL listedType Rw90 or RWU90 upon special request

Vulcanel S8000 cable type XHHW or XHHW-2 RoHS CT-SR with stranded compact class B AA-8000 series aluminum alloy soft conductor size length and product number

reg

114

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANEL EPR ANTILLAMA CABLE

600 VOLTS

26ACSR01

DESCRIPTION

FEATURES

HOW TO ORDER

SPECIFICATIONSSPECIFICATIONS

3 2 1

1) Annealed coated or un-coated stranded class B copper conductor2) Ethylene propylene rubber (EPR) insulation3) Chlorosulfonated polyethylene (Hypalon) or chlorinated polyethylene(CPE) jacket

APPLICATION

Ideally suited for use in Electrical generating stations May be installed in free air all raceways or direct burial

MAXIMUM CONDUCTOR TEMPERATUREDry LocationsDry and Wet LocationsOverloadShort Circuit

90 C75 C130 C250 C

MAXIMUM OPERATING VOLTAGE600 Volts

1) Flame resistant Meets or exceeds requirements of IEEE 383 flame test2) Deformation resistant at high temperatures3) Excellent Flexibility at low temperature suitable for installation in sub-zero temperatures4) Extra tough mechanically rugged composite insulation and jacket construction6) Resistant to most oils and chemicals

ICEA S-95-658

VULCANEL EPR ANTILLAMA cable 600 volts size length National Electrical Code ReferencesAmpacities Article 31318-10Cable Trays Article 318

Dupont trade mark

reg reg

Size Number Conductor Insulation Jacket Overall Netof Diameter Thickness Thickness Diameter Weight

AWGkcmilStrands Inch mils mils inch lbMft

8 7 015 45 15 026 79

6 7 118 45 30 042 125

4 7 023 45 30 038 179

2 7 029 45 30 043 269

10 19 037 55 45 056 432

20 19 041 55 45 061 528

30 19 047 55 45 066 647

40 19 052 55 45 071 797

250 37 057 65 45 082 982

300 37 062 65 65 087 1146

352 37 067 65 65 092 1351

400 37 072 65 65 097 1480

500 37 080 65 65 105 1782

600 61 088 80 65 116 2186

750 61 098 80 65 126 2685

1000 61 114 80 65 141 3410

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

reg reg

15

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

CODE SIZE STRAND OVERALL DIAMETER NET WEIGHT RUPTURE STRENGTH

Turkey 6 61 0198 503 36 54

Swan 4 61 0250 635 58 86

Swallow 3 61 0281 714 73 108

Sparrow 2 61 0316 803 91 136

Robin 1 61 0355 902 115 171

Raven 10 61 0398 1011 145 216

Quail 20 61 0447 1135 183 273

Pigeon 30 61 0502 1275 231 344

Penguin 40 61 0563 1430 291 433

Partridge 2668 267 0642 1631 366 544

Linnet 3364 267 0721 1831 162 688

Oriole 3364 307 0741 1882 525 782

Ibis 3975 267 0783 1989 545 811

Lark 3975 307 0806 2047 619 921

Hawk 4770 267 0858 2179 654 973

Hen 4770 307 0883 2243 743 1106

Heron 5000 307 0904 2296 781 1162

Dove 5565 267 0927 2355 765 1138

Eagle 5565 307 0953 2421 869 1293

Duck 6050 547 0953 2421 779 1159

Grosbeak 6360 267 0990 2515 872 1298

Starling 7155 267 1051 2670 986 1467

Crow 7155 547 1035 2629 918 1366

Drake 7950 267 1108 2814 1095 1629

Condor 7950 547 1093 2776 1021 1520

Canary 9000 547 1162 2951 1160 1726

Rail 9540 457 1165 2959 1076 1601

Bluejay 11130 457 1259 3198 1256 1869

11903

18608

23040

28575

35550

43875

53100

66825

84308

113175

141075

173250

163125

203175

195075

238500

247500

227250

279000

234000

252000

283500

261000

315000

281250

323370

258750

309870

WORD AWG or MCM ALSteel Inch mm Lbsmft kgkm lbs

manufacturing tolerances

Condumex can currently produce a wider

BARE ACSR CABLE

ALUMINUM CONDUCTOR STEEL REINFORCED

26ACSR01

DESCRIPTION

CONDUCTORS

Aluminum 1350 wire concentrically laid overa solid or stranded galvanized steel core

Mechanical design requirements5) Good corrosion resistance

3) High resistance to mechanical strength4) Wide variety of sizes available in long

lengths to suit both electrical and

fewer towers required

strength to permit the longest possiblespans

2) Minimum sag between supports with

1) Ideal combination of conductivity and

FEATURES

Code Word quantity required in weight

ACSR cable size Aluminum Association

HOW TO ORDER

Overhead transmission subtransmission

overhead electrical cables Messenger and

overhead lines Messenger cables to support

APPLICATION

and distribution systems Static wires to protect

power support conductor in catenary systems

for railroad electrification

SPECIFICATIONS

ASTM B498 Galvanized steel class A

ASTM B232 Conductor overall

SPECIFICATIONS

ASTM B230 Aluminum wires

MAXIMUM CONDUCTOR TEMPERATURE

Normal Operation 75 degC

116

Dimension and weights shown are nominal unless otherwise indicated and subject to

range of products then what is listedPlease contact us for other items

Grand Prairie Texas800-925-9473

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
Page 9: 5Power Cable Specs Set 2 - Condumex  · PDF fileCondumex Wire and Cable 2590 114th Street, ... Type Conductors Diameter Ampacity Weight AWG ... 6 19 26.2 0.18 30 6 0.26

1) Annealed bare stranded class B compact

copper conductor

DESCRIPTION

3) Ethylene propylene (EPR) or cross-linked

polyethylene (XLPE) insulation

4) Polyvinyl chloride (PVC) protective jacket

2) Extruded semiconducting strand shield

VULCANELreg MEDIUM VOLTAGE

WET OR DRY POWER CABLE 5 KVXLPE OR EPR NON-SHIELDED

24 13

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

Size Number Conductor Insulation Insulation Jacket OverallAWG of Diameter Thickness Diameter Thickness Diameterkcmil Strands inch inch inch mils Inch XLPE EPR

Net WeightLbMft

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

manufacturing tolerances

5kV 133 Insulation Level 115 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject to

cable voltage and insulation level conductor

Ampacities

Cable Trays

Type MV

ICEA S-66-524 AEIC CS-S (XLP)

extrusion) results in a virtually perfect cable core

- Very low dielectric loss

Normal Operation 105deg C130deg CEmergency Overload

VULCANELreg 5kv Non-shielded power cables

adequate for proper termination of the shielding

1) Simultaneous extrusion of strand shield

250deg CShort Circuit

UL 1072

326

318

310-15

National Electrical Code References

VULCANELreg EPRXLPE Non-Shielded power

size and type length and reel dimensions

SPECIFICATIONS

are ideally suited for use in industrial andutility applications where shields cannot be

APPLICATION

abrasion ozone and moisture

- Electrical stability under stress- Low dielectric loss- Chemical resistance

FEATURES

3) Easy-stripping insulation shield4) The external PVC jacket is resistant to

EPR insulation offers- Excellent heat moisture and corona

2) XLPE insulation offers- Low moisture absorption- Good resistance to chemicals

insulation and insulation shield (triple

accordance with the National ElectricalCode

5) UL listed as MV-105 sunlight resistantdirect burial Optional marking For CTuse available on single conductor in

HOW TO ORDER

resistance

MAXIMUM CONDUCTOR TEMPERATURE

Page 1 of 2

ICEA S-68-516 AEIC CS-6-87 (EPR)

6

RoHS

VULCANELreg MEDIUM VOLTAGE

WET OR DRY POWER CABLE 5 KVXLPE OR EPR NON-SHIELDED

Page 2 of 2

Size Number Conductor Insulation Insulation Jacket OverallAWG of Diameter Thickness Diameter Thickness Diameterkcmil Strands inch inch inch mils Inch XLPE EPR

Net WeightlbMft

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

25kV 100 Insulation Level 260 mils Insulation Thickness

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

35kV 100 Insulation Level 345 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

15kV 133 Insulation Level 220 mils Insulation Thickness

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

17

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANELreg MEDIUM VOLTAGE EPR

SHIELDED POWER CABLES 5 15 25 35 KV

346 125

DESCRIPTION

1) Annealed bare stranded class B compactcopper conductor

2) Extruded semiconducting strand shield3) Ethylene propylene rubber (EPR) insulation4) Extruded semiconducting insulation shield5) Annealed copper tape shield (25 overlap

6) Polyvinyl chloride (PVC) protective jacketminimum)

Three-phase electrical distribution systems

trays

Suitable for use in overhead installationsrecognized raceways direct burial or cable

APPLICATION

voltage and insulation level conductor

AmpacitiesCable TraysType MV

- Chemical resistance

5) The external PVC jacket is resistant to

- Electrical stability under stress

MAXIMUM CONDUCTOR TEMPERATURE

SPECIFICATIONS

use available on single conductor in

accordance with the National ElectricalCode

abrasion ozone and moisture6) UL listed as MV-105 sunlight resistant

direct burial Optional marking For CT

3) Easy-stripping insulation shield4) Tape shield provides high short circuit

capabilities and uniform shield impedance

- Low dielectric loss

UL 1072

size and type length and reel dimensions

ICEA S-68-516 AEIC CS6-87

326318310-15

National Electrical Code References

VULCANELreg EPR shielded power cable

2) EPR insulation offers- Excellent heat moisture and corona

resistance

insulation and insulation shield (tripleextrusion) results in a virtually perfect

cable core

250 degCShort Circuit

1) Simultaneous extrusion of strand shield

Normal Operation 105 degC130 degCEmergency Overload

FEATURES

SPECIFICATIONS

HOW TO ORDER

Page 1 of 2

Size Number Conductor Insulation Insul Shld Jacket Overall Netof Diameter Thickness Diameter Thickness Diameter Weight

AWGkcmilStrands Inch inch inch mils Inch lbMft

6 7 017 045 053 60 067 290

4 7 022 049 057 60 071 357

2 7 027 055 063 60 074 478

10 19 034 062 070 80 085 668

20 19 038 066 074 80 092 775

30 19 043 071 079 80 097 933

40 19 048 076 084 80 102 1071

250 37 052 081 090 80 107 1226

350 37 062 091 099 80 117 1560

500 37 074 103 113 80 132 2150

750 61 091 121 132 80 150 3027

1000 61 111 136 146 80 164 3845

5kV 133 Insulation Level 115 mils Insulation Thickness

2 7 027 067 075 80 093 570

10 19 034 074 082 80 100 736

20 19 038 078 086 80 104 849

30 19 043 083 091 80 109 1010

40 19 048 088 096 80 114 1190

250 37 052 094 102 80 120 1330

350 37 062 103 114 80 132 1753

500 37 074 116 126 80 144 2280

750 61 091 134 144 80 162 3142

1000 61 111 136 159 110 183 5794

5kV 100 Insulation Level 175 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

Page 2 of 2

VULCANELreg MEDIUM VOLTAGE EPR

SHIELDED POWER CABLES 5 15 25 35 KV

Size Number Conductor Insulation Insul Shld Jacket Overall Netof Diameter Thickness Diameter Thickness Diameter Weight

AWGkcmilStrands Inch inch inch mils Inch lbMft

6 7 017 045 053 60 067 290

4 7 022 049 057 60 071 357

2 7 027 055 063 60 074 478

10 19 034 062 070 80 085 668

20 19 038 066 074 80 092 775

30 19 043 071 079 80 097 933

40 19 048 076 084 80 102 1071

250 37 052 081 090 80 107 1226

350 37 062 091 099 80 117 1560

500 37 074 103 113 80 132 2150

750 61 091 121 132 80 150 3027

1000 61 111 136 146 80 164 3845

15kV 133 Insulation Level 220 mils Insulation Thickness

10 19 034 092 100 80 118 894

20 19 038 096 104 80 122 1009

30 19 043 100 111 80 129 1181

40 19 048 106 116 80 134 1394

250 37 052 111 122 80 140 1537

350 37 062 121 131 80 149 1936

500 37 074 133 143 80 161 2516

750 61 091 151 161 110 185 3620

1000 61 111 166 180 110 204 4543

25kV 100 Insulation Level 260 mils Insulation Thickness

10 19 034 109 119 80 137 1041

20 19 038 113 123 80 141 1226

30 19 043 118 128 80 146 1380

40 19 048 123 133 80 151 1569

250 37 052 129 139 80 157 1750

350 37 062 138 149 80 167 2163

500 37 074 150 161 110 185 2893

750 61 091 168 183 110 207 3900

1000 61 111 183 197 110 221 4807

35kV 100 Insulation Level 345 mils Insulation Thickness

manufacturing tolerancesDimension and weights shown are nominal unless otherwise indicated and subject to

19

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-94735-05

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

ICEA-S-68-516

SPECIFICATIONS

three conductor cable voltage size andlength

Condumex Mining Cable EPR type SHD-GC

HOW TO ORDER

MINING CABLE EPR TYPE SHD-GC

THREE CONDUCTOR 5000 VOLTS

18SHD-GC01

with a nylon webbing provides a tough defense

round configuration

and Health Administration Approval No P-218-1-MSHA

by the Pennsylvania Department of Environmental

Resources Meets MSHA flame test requirements

6) Acceptance No P-218-1-MSHA by Mines Safety

5) CV-Cured extra-heavy-duty CPE reinforced

4) Prevulcanized thermosetting non-wicking fillers

mechanical resistant jacket

resistance outstanding corona resistance

high dielectric strength and chemical resistance

designed for flexibility and resistance to

FEATURES

2) Ground check conductor facilitates fail-safe

3) EPR insulation offers excellent heat and moisture

are used if necessary to obtain a substantially

1) Special tinned copper stranded conductors

fatigue resulting from bending and flexing

ground monitoring for maximum safety

Dimension and weights shown are nominal unless otherwise indicated and subject to

6 7x3029 020 110 10 8 156

4 7x4729 025 110 8 8 168

2 7x7429 031 110 6 8 187

1 7x3725 035 110 5 8 195

10 7x4725 039 110 4 8 208

20 7x6025 045 110 3 8 220

30 7x7525 050 110 2 8 236

40 19x3525 059 110 1 8 250

300 19x4925 069 120 10 8 281

350 19x5825 076 120 20 8 295

1675

1888

2322

2653

3068

3504

4206

5023

6371

7654

Size Number of Conductor Insulation Ground Ground OverallAWG Strands Diameter Thickness Size Check Size Diameterkcmil AWG inch mils AWG AWG inch

NetWeightlbmft

manufacturing tolerances

MAXIMUM CONDUCTOR TEMPERATURE

Normal continuous 90deg C130deg COverload

250deg CShort circuit

MAXIMUM OPERATING VOLTAGE

5000 volts

Trailing cable on ac mining equipment

where service conditions are severe andmaximum safety is mandatory such as

APPLICATION

power shovels and draglines in open-pit

mines quarries gantry cranes and slag

reclaiming Also used for medium voltage

distribution in underground mines where

frequent relocation is necessary

DESCRIPTION

1) Three flexible annealed tinned copper rope-lay stranded conductors

2) Extruded semi-conducting conductor shieldand ethylene propylene rubber (EPR) insulation

3) Color coded cottoncopper braid shield applied over semi-conducting tape

4) Two annealed tinned copper rope-lay strandedgrounding conductors

5) Annealed tinned copper rope-lay stranded

and covered with a yellow cotton braid

chlorinated polyethylene (CPE) jacket

6) Rubberized cotton binder tape7) Nylon web reinforced extra-heavy-duty

ground check conductor yellow EPR insulation

346 2 157

110

RoHS

5) Overall flame retardant PVC jacket

DESCRIPTION

XLP insulation3) Fillers (if required)

4) Binder tape over core

2) Cross-Linked polyethylene thermosetting

1) Annealed bare stranded compressed

Class B copper conductors

without grounding conductorVolts number and size of conductors with or

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet

lighting control signal and communication circuitsin cable trays raceways direct burial or on

HOW TO ORDER

Condumex Tray Cable Type TCXHHW 600

SPECIFICATIONS

UL-1277 amp UL-44

APPLICATION

most chemicals in accordance with the

MAXIMUM OPERATING VOLTAGE

National Electrical Code

or dry locations and in the presence of oil and

6) Acceptable for Class 1 Division 2 HazardousLocations applications

O5) PVC jacket is UL rated 90 C and listed OilResistant I

600 volts

MAXIMUM CONDUCTOR TEMPERATUREO 90 C

O130 C

FEATURES

OverloadNormal

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

National Electrical Code

BTU flame test)3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

tray cable use in accordance with the

3 145 2

POWER CABLE TYPE TC

XHHW 600 VOLTS

Size Number Ground Insulation Jacket Overall Netof Conductor Thickness Thickness Diameter Weight

AWGkcmilConductors AWG mils mils inch lbMft

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 3 10 45 60 066 310

6 3 8 45 60 074 448

4 3 8 45 80 088 659

2 3 6 45 80 103 968

10 3 6 55 80 121 1428

20 3 4 55 80 131 1735

30 3 4 55 80 142 2150

40 3 4 55 80 154 3620

250 3 4 65 110 175 3190

350 3 3 65 110 196 4305

500 3 2 65 110 225 5940

8 4 10 45 60 073 385

6 4 8 45 80 083 568

4 4 8 45 80 097 832

2 4 6 45 80 112 1230

10 4 6 5 80 134 1825

20 4 4 55 80 145 2212

30 4 4 55 80 157 2751

40 4 4 55 110 177 3462

250 4 4 65 110 198 4097

350 4 3 65 110 217 5542

500 4 2 65 110 249 7690

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

111

7) ldquoERrdquo Listed per UL 1277

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

National Electrical Code References

Product Article 310 Table 310-13

Ampacities Article 310-15

HOW TO ORDER

CONDUMEX type RHH-RHW-USE-2

XLPE 600 volts size length quantity

packaging

DESCRIPTION

polyethylene (XLPE) insualtion

1) Annealed bare stranded class B

conductor

2) Flame-retardant cross-linked

TYPE RHH-RHW-USE-2

COPPER XLPE 600 VOLTS

APPLICATION

May be installed in free air all raceways or

underground service entrance cable

Type RHH 90deg C Dry and

temperatures

6) Stable electrical propoerties

UL-44 Standard for Rubber-Insulated

use in direct burial in industrial andcommercial application May be used as

7) Extremely tough

SPECIFICATIONS

4) Good resistance to most oils and

3) UL approved as VW-1 (RHH or RHW)

chemicals5) Suitable for installation in sub-zero

2) UL listed as types RHH or RHW or USE forresistant insulation

damp locations

ICEA S-66-524 Standard for Cross-Linked

Type RHW or 75deg C Dry and

use in accordance with the National

Electrical Code

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

MAXIMUM OPERATING VOLTAGE

USE wet locatinons

1) Flame retardant moisture and heat

FEATURES

Wires and Cables

Polyethylene Insualted Wire and Cable

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch mils inch lbMft

8 7 165 015 60 027 73

6 7 262 018 60 031 108

4 7 417 022 60 035 161

2 7 663 028 60 041 245

10 19 106 036 80 053 392

20 19 133 041 80 058 485

30 19 168 046 80 063 600

40 19 211 051 80 069 746

250 37 056 95 076 887

300 37 061 95 082 1052

350 37 066 95 087 1216

400 37 071 95 092 1380

500 37 079 95 099 1708

600 61 087 110 111 2055

750 61 097 110 120 2542

1000 61 112 110 136 3353

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

11 112

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

copper conductor

2) Cross-linked polyethylene (XLPE)

insulation

compressed (6 AWG-1000 MCM)

1) Annealed bare stranded class B

concentric round (14-8 AWG)

APPLICATION

Power or control circuits in recognized

switchboard wiring

Dry locations 90deg C

presence of oil Also suitable as

designs

temperatures

4) Suitable for installation in sub-zero

pulling and greater conduit fill

5) Optical For CT use marking for use in

cable trays Sunlight resistant in

FEATURES

2) Good moisture resistance

raceways in wet or dry location and in

90deg CWet locationsOverload 130deg CShort Circuit

MAXIMUM OPERATING VOLTAGE

3) Good resistance to most oils and

chemicals

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

accordance with NEC Article 3186) Available in VW-1 and non VW-1

UL-44

SPECIFICATIONS

Chapter 9

250deg C

1) Smaller overall diameter for easier

HOW TO ORDER

National Electrical Code References

Article 310

VULCANELreg XLPE cable type XHHW-2600 volts size and length

Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL

TYPE XHHW-2 600 VOLTS

reg XLPE CABLE

2 1

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch Mils inch lbMft

manufacturing tolerances

14 7 41 007 30 013 19

12 7 65 009 30 015 48

10 7 103 011 30 017 42

8 7 165 015 45 024 71

6 7 262 018 45 027 98

4 7 417 023 45 032 153

2 7 663 029 45 038 241

10 19 1060 037 55 048 378

20 19 1330 041 55 052 446

30 19 1680 047 55 058 556

40 19 2110 052 55 063 697

250 37 057 65 070 851

300 37 062 65 075 997

350 37 067 65 080 1180

400 37 072 65 085 1306

500 37 080 65 093 1662

600 61 088 80 104 1974

750 61 098 80 115 2450

1000 61 114 80 130 3240

Dimension and weights shown are nominal unless otherwise indicated and subject to

13

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

APPLICATION

FEATURES

MAXIMUM OPERATING VOLTAGE

MAXIMUM CONDUCTOR TEMPERATURE

UL-44

SPECIFICATIONS

Chapter 9

HOW TO ORDER

National Electrical Code References

Article 310Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL S8000

XHHW or XHHW-2 600 VOLTS ALUMINUM

reg XLPE CABLE

manufacturing tolerances

Size Number Insulations Overall Netof Thickness Diameter Weight

AWGkcmilStrands Mils In LbMft

6 7 45 027 42

4 7 45 031 59

2 7 45 036 88

1 7 55 042 111

10 19 55 045 136

20 19 55 049 165

30 19 55 054 203

40 19 55 059 250

250 37 65 066 300

300 37 65 071 354

350 37 65 075 405

500 37 65 087 562

600 61 80 098 684

750 61 80 108 840

900 61 80 117 995

Dimension and weights shown are nominal unless otherwise indicated and subject to

2 13

1) Stranded compact class B AA-8000 series aluminum alloy soft conductor2) Separator tape3) Cross-linked polyethylene (XLPE) insulation type XHHW or XHHW-2

Branch-circuits and feeders conductors in low voltage for buildings schools auditoriums hospitals stadiums museums poultry farms etc Industrial and commercial buildings For use in cable trays or raceways in wet and dry locations

600 volts

Wet and dry continuousOverloadShort circuit

90 C130 C125 C

1) Easier pulling and greater conduit fill2) Good moisture resistance3) Excellent dielectrics properties4) Continuous 90 C operating temperature in wet or dry locations5) Suitable for use in cable trays (10 AWG and greater)6) VW-1 compliant7) Sunlight resistant insulatedRoHS compliant

APPROVALS

Type XHHW or XHHW-2 UL listedType Rw90 or RWU90 upon special request

Vulcanel S8000 cable type XHHW or XHHW-2 RoHS CT-SR with stranded compact class B AA-8000 series aluminum alloy soft conductor size length and product number

reg

114

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANEL EPR ANTILLAMA CABLE

600 VOLTS

26ACSR01

DESCRIPTION

FEATURES

HOW TO ORDER

SPECIFICATIONSSPECIFICATIONS

3 2 1

1) Annealed coated or un-coated stranded class B copper conductor2) Ethylene propylene rubber (EPR) insulation3) Chlorosulfonated polyethylene (Hypalon) or chlorinated polyethylene(CPE) jacket

APPLICATION

Ideally suited for use in Electrical generating stations May be installed in free air all raceways or direct burial

MAXIMUM CONDUCTOR TEMPERATUREDry LocationsDry and Wet LocationsOverloadShort Circuit

90 C75 C130 C250 C

MAXIMUM OPERATING VOLTAGE600 Volts

1) Flame resistant Meets or exceeds requirements of IEEE 383 flame test2) Deformation resistant at high temperatures3) Excellent Flexibility at low temperature suitable for installation in sub-zero temperatures4) Extra tough mechanically rugged composite insulation and jacket construction6) Resistant to most oils and chemicals

ICEA S-95-658

VULCANEL EPR ANTILLAMA cable 600 volts size length National Electrical Code ReferencesAmpacities Article 31318-10Cable Trays Article 318

Dupont trade mark

reg reg

Size Number Conductor Insulation Jacket Overall Netof Diameter Thickness Thickness Diameter Weight

AWGkcmilStrands Inch mils mils inch lbMft

8 7 015 45 15 026 79

6 7 118 45 30 042 125

4 7 023 45 30 038 179

2 7 029 45 30 043 269

10 19 037 55 45 056 432

20 19 041 55 45 061 528

30 19 047 55 45 066 647

40 19 052 55 45 071 797

250 37 057 65 45 082 982

300 37 062 65 65 087 1146

352 37 067 65 65 092 1351

400 37 072 65 65 097 1480

500 37 080 65 65 105 1782

600 61 088 80 65 116 2186

750 61 098 80 65 126 2685

1000 61 114 80 65 141 3410

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

reg reg

15

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

CODE SIZE STRAND OVERALL DIAMETER NET WEIGHT RUPTURE STRENGTH

Turkey 6 61 0198 503 36 54

Swan 4 61 0250 635 58 86

Swallow 3 61 0281 714 73 108

Sparrow 2 61 0316 803 91 136

Robin 1 61 0355 902 115 171

Raven 10 61 0398 1011 145 216

Quail 20 61 0447 1135 183 273

Pigeon 30 61 0502 1275 231 344

Penguin 40 61 0563 1430 291 433

Partridge 2668 267 0642 1631 366 544

Linnet 3364 267 0721 1831 162 688

Oriole 3364 307 0741 1882 525 782

Ibis 3975 267 0783 1989 545 811

Lark 3975 307 0806 2047 619 921

Hawk 4770 267 0858 2179 654 973

Hen 4770 307 0883 2243 743 1106

Heron 5000 307 0904 2296 781 1162

Dove 5565 267 0927 2355 765 1138

Eagle 5565 307 0953 2421 869 1293

Duck 6050 547 0953 2421 779 1159

Grosbeak 6360 267 0990 2515 872 1298

Starling 7155 267 1051 2670 986 1467

Crow 7155 547 1035 2629 918 1366

Drake 7950 267 1108 2814 1095 1629

Condor 7950 547 1093 2776 1021 1520

Canary 9000 547 1162 2951 1160 1726

Rail 9540 457 1165 2959 1076 1601

Bluejay 11130 457 1259 3198 1256 1869

11903

18608

23040

28575

35550

43875

53100

66825

84308

113175

141075

173250

163125

203175

195075

238500

247500

227250

279000

234000

252000

283500

261000

315000

281250

323370

258750

309870

WORD AWG or MCM ALSteel Inch mm Lbsmft kgkm lbs

manufacturing tolerances

Condumex can currently produce a wider

BARE ACSR CABLE

ALUMINUM CONDUCTOR STEEL REINFORCED

26ACSR01

DESCRIPTION

CONDUCTORS

Aluminum 1350 wire concentrically laid overa solid or stranded galvanized steel core

Mechanical design requirements5) Good corrosion resistance

3) High resistance to mechanical strength4) Wide variety of sizes available in long

lengths to suit both electrical and

fewer towers required

strength to permit the longest possiblespans

2) Minimum sag between supports with

1) Ideal combination of conductivity and

FEATURES

Code Word quantity required in weight

ACSR cable size Aluminum Association

HOW TO ORDER

Overhead transmission subtransmission

overhead electrical cables Messenger and

overhead lines Messenger cables to support

APPLICATION

and distribution systems Static wires to protect

power support conductor in catenary systems

for railroad electrification

SPECIFICATIONS

ASTM B498 Galvanized steel class A

ASTM B232 Conductor overall

SPECIFICATIONS

ASTM B230 Aluminum wires

MAXIMUM CONDUCTOR TEMPERATURE

Normal Operation 75 degC

116

Dimension and weights shown are nominal unless otherwise indicated and subject to

range of products then what is listedPlease contact us for other items

Grand Prairie Texas800-925-9473

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
Page 10: 5Power Cable Specs Set 2 - Condumex  · PDF fileCondumex Wire and Cable 2590 114th Street, ... Type Conductors Diameter Ampacity Weight AWG ... 6 19 26.2 0.18 30 6 0.26

VULCANELreg MEDIUM VOLTAGE

WET OR DRY POWER CABLE 5 KVXLPE OR EPR NON-SHIELDED

Page 2 of 2

Size Number Conductor Insulation Insulation Jacket OverallAWG of Diameter Thickness Diameter Thickness Diameterkcmil Strands inch inch inch mils Inch XLPE EPR

Net WeightlbMft

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

25kV 100 Insulation Level 260 mils Insulation Thickness

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

35kV 100 Insulation Level 345 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 7 014 125 043 80 060

6 7 017 125 047 80 064

4 7 022 125 052 80 068

2 7 027 125 057 80 074

10 19 034 125 064 80 080

20 19 038 125 068 80 085

30 19 043 125 073 95 092

40 19 048 125 078 95 097

250 37 052 140 087 110 109

350 37 062 140 096 110 119

500 37 074 140 108 110 131

750 61 091 155 129 125 155

1000 61 106 155 144 125 170

190 201

234 245

298 310

394 409

539 557

639 658

788 808

944 966

1143 1171

1496 1527

2014 2030

2950 2998

3799 3854

15kV 133 Insulation Level 220 mils Insulation Thickness

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

17

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANELreg MEDIUM VOLTAGE EPR

SHIELDED POWER CABLES 5 15 25 35 KV

346 125

DESCRIPTION

1) Annealed bare stranded class B compactcopper conductor

2) Extruded semiconducting strand shield3) Ethylene propylene rubber (EPR) insulation4) Extruded semiconducting insulation shield5) Annealed copper tape shield (25 overlap

6) Polyvinyl chloride (PVC) protective jacketminimum)

Three-phase electrical distribution systems

trays

Suitable for use in overhead installationsrecognized raceways direct burial or cable

APPLICATION

voltage and insulation level conductor

AmpacitiesCable TraysType MV

- Chemical resistance

5) The external PVC jacket is resistant to

- Electrical stability under stress

MAXIMUM CONDUCTOR TEMPERATURE

SPECIFICATIONS

use available on single conductor in

accordance with the National ElectricalCode

abrasion ozone and moisture6) UL listed as MV-105 sunlight resistant

direct burial Optional marking For CT

3) Easy-stripping insulation shield4) Tape shield provides high short circuit

capabilities and uniform shield impedance

- Low dielectric loss

UL 1072

size and type length and reel dimensions

ICEA S-68-516 AEIC CS6-87

326318310-15

National Electrical Code References

VULCANELreg EPR shielded power cable

2) EPR insulation offers- Excellent heat moisture and corona

resistance

insulation and insulation shield (tripleextrusion) results in a virtually perfect

cable core

250 degCShort Circuit

1) Simultaneous extrusion of strand shield

Normal Operation 105 degC130 degCEmergency Overload

FEATURES

SPECIFICATIONS

HOW TO ORDER

Page 1 of 2

Size Number Conductor Insulation Insul Shld Jacket Overall Netof Diameter Thickness Diameter Thickness Diameter Weight

AWGkcmilStrands Inch inch inch mils Inch lbMft

6 7 017 045 053 60 067 290

4 7 022 049 057 60 071 357

2 7 027 055 063 60 074 478

10 19 034 062 070 80 085 668

20 19 038 066 074 80 092 775

30 19 043 071 079 80 097 933

40 19 048 076 084 80 102 1071

250 37 052 081 090 80 107 1226

350 37 062 091 099 80 117 1560

500 37 074 103 113 80 132 2150

750 61 091 121 132 80 150 3027

1000 61 111 136 146 80 164 3845

5kV 133 Insulation Level 115 mils Insulation Thickness

2 7 027 067 075 80 093 570

10 19 034 074 082 80 100 736

20 19 038 078 086 80 104 849

30 19 043 083 091 80 109 1010

40 19 048 088 096 80 114 1190

250 37 052 094 102 80 120 1330

350 37 062 103 114 80 132 1753

500 37 074 116 126 80 144 2280

750 61 091 134 144 80 162 3142

1000 61 111 136 159 110 183 5794

5kV 100 Insulation Level 175 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

Page 2 of 2

VULCANELreg MEDIUM VOLTAGE EPR

SHIELDED POWER CABLES 5 15 25 35 KV

Size Number Conductor Insulation Insul Shld Jacket Overall Netof Diameter Thickness Diameter Thickness Diameter Weight

AWGkcmilStrands Inch inch inch mils Inch lbMft

6 7 017 045 053 60 067 290

4 7 022 049 057 60 071 357

2 7 027 055 063 60 074 478

10 19 034 062 070 80 085 668

20 19 038 066 074 80 092 775

30 19 043 071 079 80 097 933

40 19 048 076 084 80 102 1071

250 37 052 081 090 80 107 1226

350 37 062 091 099 80 117 1560

500 37 074 103 113 80 132 2150

750 61 091 121 132 80 150 3027

1000 61 111 136 146 80 164 3845

15kV 133 Insulation Level 220 mils Insulation Thickness

10 19 034 092 100 80 118 894

20 19 038 096 104 80 122 1009

30 19 043 100 111 80 129 1181

40 19 048 106 116 80 134 1394

250 37 052 111 122 80 140 1537

350 37 062 121 131 80 149 1936

500 37 074 133 143 80 161 2516

750 61 091 151 161 110 185 3620

1000 61 111 166 180 110 204 4543

25kV 100 Insulation Level 260 mils Insulation Thickness

10 19 034 109 119 80 137 1041

20 19 038 113 123 80 141 1226

30 19 043 118 128 80 146 1380

40 19 048 123 133 80 151 1569

250 37 052 129 139 80 157 1750

350 37 062 138 149 80 167 2163

500 37 074 150 161 110 185 2893

750 61 091 168 183 110 207 3900

1000 61 111 183 197 110 221 4807

35kV 100 Insulation Level 345 mils Insulation Thickness

manufacturing tolerancesDimension and weights shown are nominal unless otherwise indicated and subject to

19

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-94735-05

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

ICEA-S-68-516

SPECIFICATIONS

three conductor cable voltage size andlength

Condumex Mining Cable EPR type SHD-GC

HOW TO ORDER

MINING CABLE EPR TYPE SHD-GC

THREE CONDUCTOR 5000 VOLTS

18SHD-GC01

with a nylon webbing provides a tough defense

round configuration

and Health Administration Approval No P-218-1-MSHA

by the Pennsylvania Department of Environmental

Resources Meets MSHA flame test requirements

6) Acceptance No P-218-1-MSHA by Mines Safety

5) CV-Cured extra-heavy-duty CPE reinforced

4) Prevulcanized thermosetting non-wicking fillers

mechanical resistant jacket

resistance outstanding corona resistance

high dielectric strength and chemical resistance

designed for flexibility and resistance to

FEATURES

2) Ground check conductor facilitates fail-safe

3) EPR insulation offers excellent heat and moisture

are used if necessary to obtain a substantially

1) Special tinned copper stranded conductors

fatigue resulting from bending and flexing

ground monitoring for maximum safety

Dimension and weights shown are nominal unless otherwise indicated and subject to

6 7x3029 020 110 10 8 156

4 7x4729 025 110 8 8 168

2 7x7429 031 110 6 8 187

1 7x3725 035 110 5 8 195

10 7x4725 039 110 4 8 208

20 7x6025 045 110 3 8 220

30 7x7525 050 110 2 8 236

40 19x3525 059 110 1 8 250

300 19x4925 069 120 10 8 281

350 19x5825 076 120 20 8 295

1675

1888

2322

2653

3068

3504

4206

5023

6371

7654

Size Number of Conductor Insulation Ground Ground OverallAWG Strands Diameter Thickness Size Check Size Diameterkcmil AWG inch mils AWG AWG inch

NetWeightlbmft

manufacturing tolerances

MAXIMUM CONDUCTOR TEMPERATURE

Normal continuous 90deg C130deg COverload

250deg CShort circuit

MAXIMUM OPERATING VOLTAGE

5000 volts

Trailing cable on ac mining equipment

where service conditions are severe andmaximum safety is mandatory such as

APPLICATION

power shovels and draglines in open-pit

mines quarries gantry cranes and slag

reclaiming Also used for medium voltage

distribution in underground mines where

frequent relocation is necessary

DESCRIPTION

1) Three flexible annealed tinned copper rope-lay stranded conductors

2) Extruded semi-conducting conductor shieldand ethylene propylene rubber (EPR) insulation

3) Color coded cottoncopper braid shield applied over semi-conducting tape

4) Two annealed tinned copper rope-lay strandedgrounding conductors

5) Annealed tinned copper rope-lay stranded

and covered with a yellow cotton braid

chlorinated polyethylene (CPE) jacket

6) Rubberized cotton binder tape7) Nylon web reinforced extra-heavy-duty

ground check conductor yellow EPR insulation

346 2 157

110

RoHS

5) Overall flame retardant PVC jacket

DESCRIPTION

XLP insulation3) Fillers (if required)

4) Binder tape over core

2) Cross-Linked polyethylene thermosetting

1) Annealed bare stranded compressed

Class B copper conductors

without grounding conductorVolts number and size of conductors with or

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet

lighting control signal and communication circuitsin cable trays raceways direct burial or on

HOW TO ORDER

Condumex Tray Cable Type TCXHHW 600

SPECIFICATIONS

UL-1277 amp UL-44

APPLICATION

most chemicals in accordance with the

MAXIMUM OPERATING VOLTAGE

National Electrical Code

or dry locations and in the presence of oil and

6) Acceptable for Class 1 Division 2 HazardousLocations applications

O5) PVC jacket is UL rated 90 C and listed OilResistant I

600 volts

MAXIMUM CONDUCTOR TEMPERATUREO 90 C

O130 C

FEATURES

OverloadNormal

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

National Electrical Code

BTU flame test)3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

tray cable use in accordance with the

3 145 2

POWER CABLE TYPE TC

XHHW 600 VOLTS

Size Number Ground Insulation Jacket Overall Netof Conductor Thickness Thickness Diameter Weight

AWGkcmilConductors AWG mils mils inch lbMft

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 3 10 45 60 066 310

6 3 8 45 60 074 448

4 3 8 45 80 088 659

2 3 6 45 80 103 968

10 3 6 55 80 121 1428

20 3 4 55 80 131 1735

30 3 4 55 80 142 2150

40 3 4 55 80 154 3620

250 3 4 65 110 175 3190

350 3 3 65 110 196 4305

500 3 2 65 110 225 5940

8 4 10 45 60 073 385

6 4 8 45 80 083 568

4 4 8 45 80 097 832

2 4 6 45 80 112 1230

10 4 6 5 80 134 1825

20 4 4 55 80 145 2212

30 4 4 55 80 157 2751

40 4 4 55 110 177 3462

250 4 4 65 110 198 4097

350 4 3 65 110 217 5542

500 4 2 65 110 249 7690

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

111

7) ldquoERrdquo Listed per UL 1277

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

National Electrical Code References

Product Article 310 Table 310-13

Ampacities Article 310-15

HOW TO ORDER

CONDUMEX type RHH-RHW-USE-2

XLPE 600 volts size length quantity

packaging

DESCRIPTION

polyethylene (XLPE) insualtion

1) Annealed bare stranded class B

conductor

2) Flame-retardant cross-linked

TYPE RHH-RHW-USE-2

COPPER XLPE 600 VOLTS

APPLICATION

May be installed in free air all raceways or

underground service entrance cable

Type RHH 90deg C Dry and

temperatures

6) Stable electrical propoerties

UL-44 Standard for Rubber-Insulated

use in direct burial in industrial andcommercial application May be used as

7) Extremely tough

SPECIFICATIONS

4) Good resistance to most oils and

3) UL approved as VW-1 (RHH or RHW)

chemicals5) Suitable for installation in sub-zero

2) UL listed as types RHH or RHW or USE forresistant insulation

damp locations

ICEA S-66-524 Standard for Cross-Linked

Type RHW or 75deg C Dry and

use in accordance with the National

Electrical Code

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

MAXIMUM OPERATING VOLTAGE

USE wet locatinons

1) Flame retardant moisture and heat

FEATURES

Wires and Cables

Polyethylene Insualted Wire and Cable

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch mils inch lbMft

8 7 165 015 60 027 73

6 7 262 018 60 031 108

4 7 417 022 60 035 161

2 7 663 028 60 041 245

10 19 106 036 80 053 392

20 19 133 041 80 058 485

30 19 168 046 80 063 600

40 19 211 051 80 069 746

250 37 056 95 076 887

300 37 061 95 082 1052

350 37 066 95 087 1216

400 37 071 95 092 1380

500 37 079 95 099 1708

600 61 087 110 111 2055

750 61 097 110 120 2542

1000 61 112 110 136 3353

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

11 112

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

copper conductor

2) Cross-linked polyethylene (XLPE)

insulation

compressed (6 AWG-1000 MCM)

1) Annealed bare stranded class B

concentric round (14-8 AWG)

APPLICATION

Power or control circuits in recognized

switchboard wiring

Dry locations 90deg C

presence of oil Also suitable as

designs

temperatures

4) Suitable for installation in sub-zero

pulling and greater conduit fill

5) Optical For CT use marking for use in

cable trays Sunlight resistant in

FEATURES

2) Good moisture resistance

raceways in wet or dry location and in

90deg CWet locationsOverload 130deg CShort Circuit

MAXIMUM OPERATING VOLTAGE

3) Good resistance to most oils and

chemicals

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

accordance with NEC Article 3186) Available in VW-1 and non VW-1

UL-44

SPECIFICATIONS

Chapter 9

250deg C

1) Smaller overall diameter for easier

HOW TO ORDER

National Electrical Code References

Article 310

VULCANELreg XLPE cable type XHHW-2600 volts size and length

Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL

TYPE XHHW-2 600 VOLTS

reg XLPE CABLE

2 1

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch Mils inch lbMft

manufacturing tolerances

14 7 41 007 30 013 19

12 7 65 009 30 015 48

10 7 103 011 30 017 42

8 7 165 015 45 024 71

6 7 262 018 45 027 98

4 7 417 023 45 032 153

2 7 663 029 45 038 241

10 19 1060 037 55 048 378

20 19 1330 041 55 052 446

30 19 1680 047 55 058 556

40 19 2110 052 55 063 697

250 37 057 65 070 851

300 37 062 65 075 997

350 37 067 65 080 1180

400 37 072 65 085 1306

500 37 080 65 093 1662

600 61 088 80 104 1974

750 61 098 80 115 2450

1000 61 114 80 130 3240

Dimension and weights shown are nominal unless otherwise indicated and subject to

13

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

APPLICATION

FEATURES

MAXIMUM OPERATING VOLTAGE

MAXIMUM CONDUCTOR TEMPERATURE

UL-44

SPECIFICATIONS

Chapter 9

HOW TO ORDER

National Electrical Code References

Article 310Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL S8000

XHHW or XHHW-2 600 VOLTS ALUMINUM

reg XLPE CABLE

manufacturing tolerances

Size Number Insulations Overall Netof Thickness Diameter Weight

AWGkcmilStrands Mils In LbMft

6 7 45 027 42

4 7 45 031 59

2 7 45 036 88

1 7 55 042 111

10 19 55 045 136

20 19 55 049 165

30 19 55 054 203

40 19 55 059 250

250 37 65 066 300

300 37 65 071 354

350 37 65 075 405

500 37 65 087 562

600 61 80 098 684

750 61 80 108 840

900 61 80 117 995

Dimension and weights shown are nominal unless otherwise indicated and subject to

2 13

1) Stranded compact class B AA-8000 series aluminum alloy soft conductor2) Separator tape3) Cross-linked polyethylene (XLPE) insulation type XHHW or XHHW-2

Branch-circuits and feeders conductors in low voltage for buildings schools auditoriums hospitals stadiums museums poultry farms etc Industrial and commercial buildings For use in cable trays or raceways in wet and dry locations

600 volts

Wet and dry continuousOverloadShort circuit

90 C130 C125 C

1) Easier pulling and greater conduit fill2) Good moisture resistance3) Excellent dielectrics properties4) Continuous 90 C operating temperature in wet or dry locations5) Suitable for use in cable trays (10 AWG and greater)6) VW-1 compliant7) Sunlight resistant insulatedRoHS compliant

APPROVALS

Type XHHW or XHHW-2 UL listedType Rw90 or RWU90 upon special request

Vulcanel S8000 cable type XHHW or XHHW-2 RoHS CT-SR with stranded compact class B AA-8000 series aluminum alloy soft conductor size length and product number

reg

114

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANEL EPR ANTILLAMA CABLE

600 VOLTS

26ACSR01

DESCRIPTION

FEATURES

HOW TO ORDER

SPECIFICATIONSSPECIFICATIONS

3 2 1

1) Annealed coated or un-coated stranded class B copper conductor2) Ethylene propylene rubber (EPR) insulation3) Chlorosulfonated polyethylene (Hypalon) or chlorinated polyethylene(CPE) jacket

APPLICATION

Ideally suited for use in Electrical generating stations May be installed in free air all raceways or direct burial

MAXIMUM CONDUCTOR TEMPERATUREDry LocationsDry and Wet LocationsOverloadShort Circuit

90 C75 C130 C250 C

MAXIMUM OPERATING VOLTAGE600 Volts

1) Flame resistant Meets or exceeds requirements of IEEE 383 flame test2) Deformation resistant at high temperatures3) Excellent Flexibility at low temperature suitable for installation in sub-zero temperatures4) Extra tough mechanically rugged composite insulation and jacket construction6) Resistant to most oils and chemicals

ICEA S-95-658

VULCANEL EPR ANTILLAMA cable 600 volts size length National Electrical Code ReferencesAmpacities Article 31318-10Cable Trays Article 318

Dupont trade mark

reg reg

Size Number Conductor Insulation Jacket Overall Netof Diameter Thickness Thickness Diameter Weight

AWGkcmilStrands Inch mils mils inch lbMft

8 7 015 45 15 026 79

6 7 118 45 30 042 125

4 7 023 45 30 038 179

2 7 029 45 30 043 269

10 19 037 55 45 056 432

20 19 041 55 45 061 528

30 19 047 55 45 066 647

40 19 052 55 45 071 797

250 37 057 65 45 082 982

300 37 062 65 65 087 1146

352 37 067 65 65 092 1351

400 37 072 65 65 097 1480

500 37 080 65 65 105 1782

600 61 088 80 65 116 2186

750 61 098 80 65 126 2685

1000 61 114 80 65 141 3410

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

reg reg

15

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

CODE SIZE STRAND OVERALL DIAMETER NET WEIGHT RUPTURE STRENGTH

Turkey 6 61 0198 503 36 54

Swan 4 61 0250 635 58 86

Swallow 3 61 0281 714 73 108

Sparrow 2 61 0316 803 91 136

Robin 1 61 0355 902 115 171

Raven 10 61 0398 1011 145 216

Quail 20 61 0447 1135 183 273

Pigeon 30 61 0502 1275 231 344

Penguin 40 61 0563 1430 291 433

Partridge 2668 267 0642 1631 366 544

Linnet 3364 267 0721 1831 162 688

Oriole 3364 307 0741 1882 525 782

Ibis 3975 267 0783 1989 545 811

Lark 3975 307 0806 2047 619 921

Hawk 4770 267 0858 2179 654 973

Hen 4770 307 0883 2243 743 1106

Heron 5000 307 0904 2296 781 1162

Dove 5565 267 0927 2355 765 1138

Eagle 5565 307 0953 2421 869 1293

Duck 6050 547 0953 2421 779 1159

Grosbeak 6360 267 0990 2515 872 1298

Starling 7155 267 1051 2670 986 1467

Crow 7155 547 1035 2629 918 1366

Drake 7950 267 1108 2814 1095 1629

Condor 7950 547 1093 2776 1021 1520

Canary 9000 547 1162 2951 1160 1726

Rail 9540 457 1165 2959 1076 1601

Bluejay 11130 457 1259 3198 1256 1869

11903

18608

23040

28575

35550

43875

53100

66825

84308

113175

141075

173250

163125

203175

195075

238500

247500

227250

279000

234000

252000

283500

261000

315000

281250

323370

258750

309870

WORD AWG or MCM ALSteel Inch mm Lbsmft kgkm lbs

manufacturing tolerances

Condumex can currently produce a wider

BARE ACSR CABLE

ALUMINUM CONDUCTOR STEEL REINFORCED

26ACSR01

DESCRIPTION

CONDUCTORS

Aluminum 1350 wire concentrically laid overa solid or stranded galvanized steel core

Mechanical design requirements5) Good corrosion resistance

3) High resistance to mechanical strength4) Wide variety of sizes available in long

lengths to suit both electrical and

fewer towers required

strength to permit the longest possiblespans

2) Minimum sag between supports with

1) Ideal combination of conductivity and

FEATURES

Code Word quantity required in weight

ACSR cable size Aluminum Association

HOW TO ORDER

Overhead transmission subtransmission

overhead electrical cables Messenger and

overhead lines Messenger cables to support

APPLICATION

and distribution systems Static wires to protect

power support conductor in catenary systems

for railroad electrification

SPECIFICATIONS

ASTM B498 Galvanized steel class A

ASTM B232 Conductor overall

SPECIFICATIONS

ASTM B230 Aluminum wires

MAXIMUM CONDUCTOR TEMPERATURE

Normal Operation 75 degC

116

Dimension and weights shown are nominal unless otherwise indicated and subject to

range of products then what is listedPlease contact us for other items

Grand Prairie Texas800-925-9473

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
Page 11: 5Power Cable Specs Set 2 - Condumex  · PDF fileCondumex Wire and Cable 2590 114th Street, ... Type Conductors Diameter Ampacity Weight AWG ... 6 19 26.2 0.18 30 6 0.26

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANELreg MEDIUM VOLTAGE EPR

SHIELDED POWER CABLES 5 15 25 35 KV

346 125

DESCRIPTION

1) Annealed bare stranded class B compactcopper conductor

2) Extruded semiconducting strand shield3) Ethylene propylene rubber (EPR) insulation4) Extruded semiconducting insulation shield5) Annealed copper tape shield (25 overlap

6) Polyvinyl chloride (PVC) protective jacketminimum)

Three-phase electrical distribution systems

trays

Suitable for use in overhead installationsrecognized raceways direct burial or cable

APPLICATION

voltage and insulation level conductor

AmpacitiesCable TraysType MV

- Chemical resistance

5) The external PVC jacket is resistant to

- Electrical stability under stress

MAXIMUM CONDUCTOR TEMPERATURE

SPECIFICATIONS

use available on single conductor in

accordance with the National ElectricalCode

abrasion ozone and moisture6) UL listed as MV-105 sunlight resistant

direct burial Optional marking For CT

3) Easy-stripping insulation shield4) Tape shield provides high short circuit

capabilities and uniform shield impedance

- Low dielectric loss

UL 1072

size and type length and reel dimensions

ICEA S-68-516 AEIC CS6-87

326318310-15

National Electrical Code References

VULCANELreg EPR shielded power cable

2) EPR insulation offers- Excellent heat moisture and corona

resistance

insulation and insulation shield (tripleextrusion) results in a virtually perfect

cable core

250 degCShort Circuit

1) Simultaneous extrusion of strand shield

Normal Operation 105 degC130 degCEmergency Overload

FEATURES

SPECIFICATIONS

HOW TO ORDER

Page 1 of 2

Size Number Conductor Insulation Insul Shld Jacket Overall Netof Diameter Thickness Diameter Thickness Diameter Weight

AWGkcmilStrands Inch inch inch mils Inch lbMft

6 7 017 045 053 60 067 290

4 7 022 049 057 60 071 357

2 7 027 055 063 60 074 478

10 19 034 062 070 80 085 668

20 19 038 066 074 80 092 775

30 19 043 071 079 80 097 933

40 19 048 076 084 80 102 1071

250 37 052 081 090 80 107 1226

350 37 062 091 099 80 117 1560

500 37 074 103 113 80 132 2150

750 61 091 121 132 80 150 3027

1000 61 111 136 146 80 164 3845

5kV 133 Insulation Level 115 mils Insulation Thickness

2 7 027 067 075 80 093 570

10 19 034 074 082 80 100 736

20 19 038 078 086 80 104 849

30 19 043 083 091 80 109 1010

40 19 048 088 096 80 114 1190

250 37 052 094 102 80 120 1330

350 37 062 103 114 80 132 1753

500 37 074 116 126 80 144 2280

750 61 091 134 144 80 162 3142

1000 61 111 136 159 110 183 5794

5kV 100 Insulation Level 175 mils Insulation Thickness

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

Page 2 of 2

VULCANELreg MEDIUM VOLTAGE EPR

SHIELDED POWER CABLES 5 15 25 35 KV

Size Number Conductor Insulation Insul Shld Jacket Overall Netof Diameter Thickness Diameter Thickness Diameter Weight

AWGkcmilStrands Inch inch inch mils Inch lbMft

6 7 017 045 053 60 067 290

4 7 022 049 057 60 071 357

2 7 027 055 063 60 074 478

10 19 034 062 070 80 085 668

20 19 038 066 074 80 092 775

30 19 043 071 079 80 097 933

40 19 048 076 084 80 102 1071

250 37 052 081 090 80 107 1226

350 37 062 091 099 80 117 1560

500 37 074 103 113 80 132 2150

750 61 091 121 132 80 150 3027

1000 61 111 136 146 80 164 3845

15kV 133 Insulation Level 220 mils Insulation Thickness

10 19 034 092 100 80 118 894

20 19 038 096 104 80 122 1009

30 19 043 100 111 80 129 1181

40 19 048 106 116 80 134 1394

250 37 052 111 122 80 140 1537

350 37 062 121 131 80 149 1936

500 37 074 133 143 80 161 2516

750 61 091 151 161 110 185 3620

1000 61 111 166 180 110 204 4543

25kV 100 Insulation Level 260 mils Insulation Thickness

10 19 034 109 119 80 137 1041

20 19 038 113 123 80 141 1226

30 19 043 118 128 80 146 1380

40 19 048 123 133 80 151 1569

250 37 052 129 139 80 157 1750

350 37 062 138 149 80 167 2163

500 37 074 150 161 110 185 2893

750 61 091 168 183 110 207 3900

1000 61 111 183 197 110 221 4807

35kV 100 Insulation Level 345 mils Insulation Thickness

manufacturing tolerancesDimension and weights shown are nominal unless otherwise indicated and subject to

19

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-94735-05

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

ICEA-S-68-516

SPECIFICATIONS

three conductor cable voltage size andlength

Condumex Mining Cable EPR type SHD-GC

HOW TO ORDER

MINING CABLE EPR TYPE SHD-GC

THREE CONDUCTOR 5000 VOLTS

18SHD-GC01

with a nylon webbing provides a tough defense

round configuration

and Health Administration Approval No P-218-1-MSHA

by the Pennsylvania Department of Environmental

Resources Meets MSHA flame test requirements

6) Acceptance No P-218-1-MSHA by Mines Safety

5) CV-Cured extra-heavy-duty CPE reinforced

4) Prevulcanized thermosetting non-wicking fillers

mechanical resistant jacket

resistance outstanding corona resistance

high dielectric strength and chemical resistance

designed for flexibility and resistance to

FEATURES

2) Ground check conductor facilitates fail-safe

3) EPR insulation offers excellent heat and moisture

are used if necessary to obtain a substantially

1) Special tinned copper stranded conductors

fatigue resulting from bending and flexing

ground monitoring for maximum safety

Dimension and weights shown are nominal unless otherwise indicated and subject to

6 7x3029 020 110 10 8 156

4 7x4729 025 110 8 8 168

2 7x7429 031 110 6 8 187

1 7x3725 035 110 5 8 195

10 7x4725 039 110 4 8 208

20 7x6025 045 110 3 8 220

30 7x7525 050 110 2 8 236

40 19x3525 059 110 1 8 250

300 19x4925 069 120 10 8 281

350 19x5825 076 120 20 8 295

1675

1888

2322

2653

3068

3504

4206

5023

6371

7654

Size Number of Conductor Insulation Ground Ground OverallAWG Strands Diameter Thickness Size Check Size Diameterkcmil AWG inch mils AWG AWG inch

NetWeightlbmft

manufacturing tolerances

MAXIMUM CONDUCTOR TEMPERATURE

Normal continuous 90deg C130deg COverload

250deg CShort circuit

MAXIMUM OPERATING VOLTAGE

5000 volts

Trailing cable on ac mining equipment

where service conditions are severe andmaximum safety is mandatory such as

APPLICATION

power shovels and draglines in open-pit

mines quarries gantry cranes and slag

reclaiming Also used for medium voltage

distribution in underground mines where

frequent relocation is necessary

DESCRIPTION

1) Three flexible annealed tinned copper rope-lay stranded conductors

2) Extruded semi-conducting conductor shieldand ethylene propylene rubber (EPR) insulation

3) Color coded cottoncopper braid shield applied over semi-conducting tape

4) Two annealed tinned copper rope-lay strandedgrounding conductors

5) Annealed tinned copper rope-lay stranded

and covered with a yellow cotton braid

chlorinated polyethylene (CPE) jacket

6) Rubberized cotton binder tape7) Nylon web reinforced extra-heavy-duty

ground check conductor yellow EPR insulation

346 2 157

110

RoHS

5) Overall flame retardant PVC jacket

DESCRIPTION

XLP insulation3) Fillers (if required)

4) Binder tape over core

2) Cross-Linked polyethylene thermosetting

1) Annealed bare stranded compressed

Class B copper conductors

without grounding conductorVolts number and size of conductors with or

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet

lighting control signal and communication circuitsin cable trays raceways direct burial or on

HOW TO ORDER

Condumex Tray Cable Type TCXHHW 600

SPECIFICATIONS

UL-1277 amp UL-44

APPLICATION

most chemicals in accordance with the

MAXIMUM OPERATING VOLTAGE

National Electrical Code

or dry locations and in the presence of oil and

6) Acceptable for Class 1 Division 2 HazardousLocations applications

O5) PVC jacket is UL rated 90 C and listed OilResistant I

600 volts

MAXIMUM CONDUCTOR TEMPERATUREO 90 C

O130 C

FEATURES

OverloadNormal

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

National Electrical Code

BTU flame test)3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

tray cable use in accordance with the

3 145 2

POWER CABLE TYPE TC

XHHW 600 VOLTS

Size Number Ground Insulation Jacket Overall Netof Conductor Thickness Thickness Diameter Weight

AWGkcmilConductors AWG mils mils inch lbMft

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 3 10 45 60 066 310

6 3 8 45 60 074 448

4 3 8 45 80 088 659

2 3 6 45 80 103 968

10 3 6 55 80 121 1428

20 3 4 55 80 131 1735

30 3 4 55 80 142 2150

40 3 4 55 80 154 3620

250 3 4 65 110 175 3190

350 3 3 65 110 196 4305

500 3 2 65 110 225 5940

8 4 10 45 60 073 385

6 4 8 45 80 083 568

4 4 8 45 80 097 832

2 4 6 45 80 112 1230

10 4 6 5 80 134 1825

20 4 4 55 80 145 2212

30 4 4 55 80 157 2751

40 4 4 55 110 177 3462

250 4 4 65 110 198 4097

350 4 3 65 110 217 5542

500 4 2 65 110 249 7690

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

111

7) ldquoERrdquo Listed per UL 1277

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

National Electrical Code References

Product Article 310 Table 310-13

Ampacities Article 310-15

HOW TO ORDER

CONDUMEX type RHH-RHW-USE-2

XLPE 600 volts size length quantity

packaging

DESCRIPTION

polyethylene (XLPE) insualtion

1) Annealed bare stranded class B

conductor

2) Flame-retardant cross-linked

TYPE RHH-RHW-USE-2

COPPER XLPE 600 VOLTS

APPLICATION

May be installed in free air all raceways or

underground service entrance cable

Type RHH 90deg C Dry and

temperatures

6) Stable electrical propoerties

UL-44 Standard for Rubber-Insulated

use in direct burial in industrial andcommercial application May be used as

7) Extremely tough

SPECIFICATIONS

4) Good resistance to most oils and

3) UL approved as VW-1 (RHH or RHW)

chemicals5) Suitable for installation in sub-zero

2) UL listed as types RHH or RHW or USE forresistant insulation

damp locations

ICEA S-66-524 Standard for Cross-Linked

Type RHW or 75deg C Dry and

use in accordance with the National

Electrical Code

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

MAXIMUM OPERATING VOLTAGE

USE wet locatinons

1) Flame retardant moisture and heat

FEATURES

Wires and Cables

Polyethylene Insualted Wire and Cable

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch mils inch lbMft

8 7 165 015 60 027 73

6 7 262 018 60 031 108

4 7 417 022 60 035 161

2 7 663 028 60 041 245

10 19 106 036 80 053 392

20 19 133 041 80 058 485

30 19 168 046 80 063 600

40 19 211 051 80 069 746

250 37 056 95 076 887

300 37 061 95 082 1052

350 37 066 95 087 1216

400 37 071 95 092 1380

500 37 079 95 099 1708

600 61 087 110 111 2055

750 61 097 110 120 2542

1000 61 112 110 136 3353

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

11 112

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

copper conductor

2) Cross-linked polyethylene (XLPE)

insulation

compressed (6 AWG-1000 MCM)

1) Annealed bare stranded class B

concentric round (14-8 AWG)

APPLICATION

Power or control circuits in recognized

switchboard wiring

Dry locations 90deg C

presence of oil Also suitable as

designs

temperatures

4) Suitable for installation in sub-zero

pulling and greater conduit fill

5) Optical For CT use marking for use in

cable trays Sunlight resistant in

FEATURES

2) Good moisture resistance

raceways in wet or dry location and in

90deg CWet locationsOverload 130deg CShort Circuit

MAXIMUM OPERATING VOLTAGE

3) Good resistance to most oils and

chemicals

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

accordance with NEC Article 3186) Available in VW-1 and non VW-1

UL-44

SPECIFICATIONS

Chapter 9

250deg C

1) Smaller overall diameter for easier

HOW TO ORDER

National Electrical Code References

Article 310

VULCANELreg XLPE cable type XHHW-2600 volts size and length

Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL

TYPE XHHW-2 600 VOLTS

reg XLPE CABLE

2 1

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch Mils inch lbMft

manufacturing tolerances

14 7 41 007 30 013 19

12 7 65 009 30 015 48

10 7 103 011 30 017 42

8 7 165 015 45 024 71

6 7 262 018 45 027 98

4 7 417 023 45 032 153

2 7 663 029 45 038 241

10 19 1060 037 55 048 378

20 19 1330 041 55 052 446

30 19 1680 047 55 058 556

40 19 2110 052 55 063 697

250 37 057 65 070 851

300 37 062 65 075 997

350 37 067 65 080 1180

400 37 072 65 085 1306

500 37 080 65 093 1662

600 61 088 80 104 1974

750 61 098 80 115 2450

1000 61 114 80 130 3240

Dimension and weights shown are nominal unless otherwise indicated and subject to

13

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

APPLICATION

FEATURES

MAXIMUM OPERATING VOLTAGE

MAXIMUM CONDUCTOR TEMPERATURE

UL-44

SPECIFICATIONS

Chapter 9

HOW TO ORDER

National Electrical Code References

Article 310Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL S8000

XHHW or XHHW-2 600 VOLTS ALUMINUM

reg XLPE CABLE

manufacturing tolerances

Size Number Insulations Overall Netof Thickness Diameter Weight

AWGkcmilStrands Mils In LbMft

6 7 45 027 42

4 7 45 031 59

2 7 45 036 88

1 7 55 042 111

10 19 55 045 136

20 19 55 049 165

30 19 55 054 203

40 19 55 059 250

250 37 65 066 300

300 37 65 071 354

350 37 65 075 405

500 37 65 087 562

600 61 80 098 684

750 61 80 108 840

900 61 80 117 995

Dimension and weights shown are nominal unless otherwise indicated and subject to

2 13

1) Stranded compact class B AA-8000 series aluminum alloy soft conductor2) Separator tape3) Cross-linked polyethylene (XLPE) insulation type XHHW or XHHW-2

Branch-circuits and feeders conductors in low voltage for buildings schools auditoriums hospitals stadiums museums poultry farms etc Industrial and commercial buildings For use in cable trays or raceways in wet and dry locations

600 volts

Wet and dry continuousOverloadShort circuit

90 C130 C125 C

1) Easier pulling and greater conduit fill2) Good moisture resistance3) Excellent dielectrics properties4) Continuous 90 C operating temperature in wet or dry locations5) Suitable for use in cable trays (10 AWG and greater)6) VW-1 compliant7) Sunlight resistant insulatedRoHS compliant

APPROVALS

Type XHHW or XHHW-2 UL listedType Rw90 or RWU90 upon special request

Vulcanel S8000 cable type XHHW or XHHW-2 RoHS CT-SR with stranded compact class B AA-8000 series aluminum alloy soft conductor size length and product number

reg

114

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANEL EPR ANTILLAMA CABLE

600 VOLTS

26ACSR01

DESCRIPTION

FEATURES

HOW TO ORDER

SPECIFICATIONSSPECIFICATIONS

3 2 1

1) Annealed coated or un-coated stranded class B copper conductor2) Ethylene propylene rubber (EPR) insulation3) Chlorosulfonated polyethylene (Hypalon) or chlorinated polyethylene(CPE) jacket

APPLICATION

Ideally suited for use in Electrical generating stations May be installed in free air all raceways or direct burial

MAXIMUM CONDUCTOR TEMPERATUREDry LocationsDry and Wet LocationsOverloadShort Circuit

90 C75 C130 C250 C

MAXIMUM OPERATING VOLTAGE600 Volts

1) Flame resistant Meets or exceeds requirements of IEEE 383 flame test2) Deformation resistant at high temperatures3) Excellent Flexibility at low temperature suitable for installation in sub-zero temperatures4) Extra tough mechanically rugged composite insulation and jacket construction6) Resistant to most oils and chemicals

ICEA S-95-658

VULCANEL EPR ANTILLAMA cable 600 volts size length National Electrical Code ReferencesAmpacities Article 31318-10Cable Trays Article 318

Dupont trade mark

reg reg

Size Number Conductor Insulation Jacket Overall Netof Diameter Thickness Thickness Diameter Weight

AWGkcmilStrands Inch mils mils inch lbMft

8 7 015 45 15 026 79

6 7 118 45 30 042 125

4 7 023 45 30 038 179

2 7 029 45 30 043 269

10 19 037 55 45 056 432

20 19 041 55 45 061 528

30 19 047 55 45 066 647

40 19 052 55 45 071 797

250 37 057 65 45 082 982

300 37 062 65 65 087 1146

352 37 067 65 65 092 1351

400 37 072 65 65 097 1480

500 37 080 65 65 105 1782

600 61 088 80 65 116 2186

750 61 098 80 65 126 2685

1000 61 114 80 65 141 3410

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

reg reg

15

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

CODE SIZE STRAND OVERALL DIAMETER NET WEIGHT RUPTURE STRENGTH

Turkey 6 61 0198 503 36 54

Swan 4 61 0250 635 58 86

Swallow 3 61 0281 714 73 108

Sparrow 2 61 0316 803 91 136

Robin 1 61 0355 902 115 171

Raven 10 61 0398 1011 145 216

Quail 20 61 0447 1135 183 273

Pigeon 30 61 0502 1275 231 344

Penguin 40 61 0563 1430 291 433

Partridge 2668 267 0642 1631 366 544

Linnet 3364 267 0721 1831 162 688

Oriole 3364 307 0741 1882 525 782

Ibis 3975 267 0783 1989 545 811

Lark 3975 307 0806 2047 619 921

Hawk 4770 267 0858 2179 654 973

Hen 4770 307 0883 2243 743 1106

Heron 5000 307 0904 2296 781 1162

Dove 5565 267 0927 2355 765 1138

Eagle 5565 307 0953 2421 869 1293

Duck 6050 547 0953 2421 779 1159

Grosbeak 6360 267 0990 2515 872 1298

Starling 7155 267 1051 2670 986 1467

Crow 7155 547 1035 2629 918 1366

Drake 7950 267 1108 2814 1095 1629

Condor 7950 547 1093 2776 1021 1520

Canary 9000 547 1162 2951 1160 1726

Rail 9540 457 1165 2959 1076 1601

Bluejay 11130 457 1259 3198 1256 1869

11903

18608

23040

28575

35550

43875

53100

66825

84308

113175

141075

173250

163125

203175

195075

238500

247500

227250

279000

234000

252000

283500

261000

315000

281250

323370

258750

309870

WORD AWG or MCM ALSteel Inch mm Lbsmft kgkm lbs

manufacturing tolerances

Condumex can currently produce a wider

BARE ACSR CABLE

ALUMINUM CONDUCTOR STEEL REINFORCED

26ACSR01

DESCRIPTION

CONDUCTORS

Aluminum 1350 wire concentrically laid overa solid or stranded galvanized steel core

Mechanical design requirements5) Good corrosion resistance

3) High resistance to mechanical strength4) Wide variety of sizes available in long

lengths to suit both electrical and

fewer towers required

strength to permit the longest possiblespans

2) Minimum sag between supports with

1) Ideal combination of conductivity and

FEATURES

Code Word quantity required in weight

ACSR cable size Aluminum Association

HOW TO ORDER

Overhead transmission subtransmission

overhead electrical cables Messenger and

overhead lines Messenger cables to support

APPLICATION

and distribution systems Static wires to protect

power support conductor in catenary systems

for railroad electrification

SPECIFICATIONS

ASTM B498 Galvanized steel class A

ASTM B232 Conductor overall

SPECIFICATIONS

ASTM B230 Aluminum wires

MAXIMUM CONDUCTOR TEMPERATURE

Normal Operation 75 degC

116

Dimension and weights shown are nominal unless otherwise indicated and subject to

range of products then what is listedPlease contact us for other items

Grand Prairie Texas800-925-9473

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
Page 12: 5Power Cable Specs Set 2 - Condumex  · PDF fileCondumex Wire and Cable 2590 114th Street, ... Type Conductors Diameter Ampacity Weight AWG ... 6 19 26.2 0.18 30 6 0.26

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

Page 2 of 2

VULCANELreg MEDIUM VOLTAGE EPR

SHIELDED POWER CABLES 5 15 25 35 KV

Size Number Conductor Insulation Insul Shld Jacket Overall Netof Diameter Thickness Diameter Thickness Diameter Weight

AWGkcmilStrands Inch inch inch mils Inch lbMft

6 7 017 045 053 60 067 290

4 7 022 049 057 60 071 357

2 7 027 055 063 60 074 478

10 19 034 062 070 80 085 668

20 19 038 066 074 80 092 775

30 19 043 071 079 80 097 933

40 19 048 076 084 80 102 1071

250 37 052 081 090 80 107 1226

350 37 062 091 099 80 117 1560

500 37 074 103 113 80 132 2150

750 61 091 121 132 80 150 3027

1000 61 111 136 146 80 164 3845

15kV 133 Insulation Level 220 mils Insulation Thickness

10 19 034 092 100 80 118 894

20 19 038 096 104 80 122 1009

30 19 043 100 111 80 129 1181

40 19 048 106 116 80 134 1394

250 37 052 111 122 80 140 1537

350 37 062 121 131 80 149 1936

500 37 074 133 143 80 161 2516

750 61 091 151 161 110 185 3620

1000 61 111 166 180 110 204 4543

25kV 100 Insulation Level 260 mils Insulation Thickness

10 19 034 109 119 80 137 1041

20 19 038 113 123 80 141 1226

30 19 043 118 128 80 146 1380

40 19 048 123 133 80 151 1569

250 37 052 129 139 80 157 1750

350 37 062 138 149 80 167 2163

500 37 074 150 161 110 185 2893

750 61 091 168 183 110 207 3900

1000 61 111 183 197 110 221 4807

35kV 100 Insulation Level 345 mils Insulation Thickness

manufacturing tolerancesDimension and weights shown are nominal unless otherwise indicated and subject to

19

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-94735-05

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

ICEA-S-68-516

SPECIFICATIONS

three conductor cable voltage size andlength

Condumex Mining Cable EPR type SHD-GC

HOW TO ORDER

MINING CABLE EPR TYPE SHD-GC

THREE CONDUCTOR 5000 VOLTS

18SHD-GC01

with a nylon webbing provides a tough defense

round configuration

and Health Administration Approval No P-218-1-MSHA

by the Pennsylvania Department of Environmental

Resources Meets MSHA flame test requirements

6) Acceptance No P-218-1-MSHA by Mines Safety

5) CV-Cured extra-heavy-duty CPE reinforced

4) Prevulcanized thermosetting non-wicking fillers

mechanical resistant jacket

resistance outstanding corona resistance

high dielectric strength and chemical resistance

designed for flexibility and resistance to

FEATURES

2) Ground check conductor facilitates fail-safe

3) EPR insulation offers excellent heat and moisture

are used if necessary to obtain a substantially

1) Special tinned copper stranded conductors

fatigue resulting from bending and flexing

ground monitoring for maximum safety

Dimension and weights shown are nominal unless otherwise indicated and subject to

6 7x3029 020 110 10 8 156

4 7x4729 025 110 8 8 168

2 7x7429 031 110 6 8 187

1 7x3725 035 110 5 8 195

10 7x4725 039 110 4 8 208

20 7x6025 045 110 3 8 220

30 7x7525 050 110 2 8 236

40 19x3525 059 110 1 8 250

300 19x4925 069 120 10 8 281

350 19x5825 076 120 20 8 295

1675

1888

2322

2653

3068

3504

4206

5023

6371

7654

Size Number of Conductor Insulation Ground Ground OverallAWG Strands Diameter Thickness Size Check Size Diameterkcmil AWG inch mils AWG AWG inch

NetWeightlbmft

manufacturing tolerances

MAXIMUM CONDUCTOR TEMPERATURE

Normal continuous 90deg C130deg COverload

250deg CShort circuit

MAXIMUM OPERATING VOLTAGE

5000 volts

Trailing cable on ac mining equipment

where service conditions are severe andmaximum safety is mandatory such as

APPLICATION

power shovels and draglines in open-pit

mines quarries gantry cranes and slag

reclaiming Also used for medium voltage

distribution in underground mines where

frequent relocation is necessary

DESCRIPTION

1) Three flexible annealed tinned copper rope-lay stranded conductors

2) Extruded semi-conducting conductor shieldand ethylene propylene rubber (EPR) insulation

3) Color coded cottoncopper braid shield applied over semi-conducting tape

4) Two annealed tinned copper rope-lay strandedgrounding conductors

5) Annealed tinned copper rope-lay stranded

and covered with a yellow cotton braid

chlorinated polyethylene (CPE) jacket

6) Rubberized cotton binder tape7) Nylon web reinforced extra-heavy-duty

ground check conductor yellow EPR insulation

346 2 157

110

RoHS

5) Overall flame retardant PVC jacket

DESCRIPTION

XLP insulation3) Fillers (if required)

4) Binder tape over core

2) Cross-Linked polyethylene thermosetting

1) Annealed bare stranded compressed

Class B copper conductors

without grounding conductorVolts number and size of conductors with or

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet

lighting control signal and communication circuitsin cable trays raceways direct burial or on

HOW TO ORDER

Condumex Tray Cable Type TCXHHW 600

SPECIFICATIONS

UL-1277 amp UL-44

APPLICATION

most chemicals in accordance with the

MAXIMUM OPERATING VOLTAGE

National Electrical Code

or dry locations and in the presence of oil and

6) Acceptable for Class 1 Division 2 HazardousLocations applications

O5) PVC jacket is UL rated 90 C and listed OilResistant I

600 volts

MAXIMUM CONDUCTOR TEMPERATUREO 90 C

O130 C

FEATURES

OverloadNormal

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

National Electrical Code

BTU flame test)3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

tray cable use in accordance with the

3 145 2

POWER CABLE TYPE TC

XHHW 600 VOLTS

Size Number Ground Insulation Jacket Overall Netof Conductor Thickness Thickness Diameter Weight

AWGkcmilConductors AWG mils mils inch lbMft

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 3 10 45 60 066 310

6 3 8 45 60 074 448

4 3 8 45 80 088 659

2 3 6 45 80 103 968

10 3 6 55 80 121 1428

20 3 4 55 80 131 1735

30 3 4 55 80 142 2150

40 3 4 55 80 154 3620

250 3 4 65 110 175 3190

350 3 3 65 110 196 4305

500 3 2 65 110 225 5940

8 4 10 45 60 073 385

6 4 8 45 80 083 568

4 4 8 45 80 097 832

2 4 6 45 80 112 1230

10 4 6 5 80 134 1825

20 4 4 55 80 145 2212

30 4 4 55 80 157 2751

40 4 4 55 110 177 3462

250 4 4 65 110 198 4097

350 4 3 65 110 217 5542

500 4 2 65 110 249 7690

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

111

7) ldquoERrdquo Listed per UL 1277

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

National Electrical Code References

Product Article 310 Table 310-13

Ampacities Article 310-15

HOW TO ORDER

CONDUMEX type RHH-RHW-USE-2

XLPE 600 volts size length quantity

packaging

DESCRIPTION

polyethylene (XLPE) insualtion

1) Annealed bare stranded class B

conductor

2) Flame-retardant cross-linked

TYPE RHH-RHW-USE-2

COPPER XLPE 600 VOLTS

APPLICATION

May be installed in free air all raceways or

underground service entrance cable

Type RHH 90deg C Dry and

temperatures

6) Stable electrical propoerties

UL-44 Standard for Rubber-Insulated

use in direct burial in industrial andcommercial application May be used as

7) Extremely tough

SPECIFICATIONS

4) Good resistance to most oils and

3) UL approved as VW-1 (RHH or RHW)

chemicals5) Suitable for installation in sub-zero

2) UL listed as types RHH or RHW or USE forresistant insulation

damp locations

ICEA S-66-524 Standard for Cross-Linked

Type RHW or 75deg C Dry and

use in accordance with the National

Electrical Code

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

MAXIMUM OPERATING VOLTAGE

USE wet locatinons

1) Flame retardant moisture and heat

FEATURES

Wires and Cables

Polyethylene Insualted Wire and Cable

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch mils inch lbMft

8 7 165 015 60 027 73

6 7 262 018 60 031 108

4 7 417 022 60 035 161

2 7 663 028 60 041 245

10 19 106 036 80 053 392

20 19 133 041 80 058 485

30 19 168 046 80 063 600

40 19 211 051 80 069 746

250 37 056 95 076 887

300 37 061 95 082 1052

350 37 066 95 087 1216

400 37 071 95 092 1380

500 37 079 95 099 1708

600 61 087 110 111 2055

750 61 097 110 120 2542

1000 61 112 110 136 3353

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

11 112

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

copper conductor

2) Cross-linked polyethylene (XLPE)

insulation

compressed (6 AWG-1000 MCM)

1) Annealed bare stranded class B

concentric round (14-8 AWG)

APPLICATION

Power or control circuits in recognized

switchboard wiring

Dry locations 90deg C

presence of oil Also suitable as

designs

temperatures

4) Suitable for installation in sub-zero

pulling and greater conduit fill

5) Optical For CT use marking for use in

cable trays Sunlight resistant in

FEATURES

2) Good moisture resistance

raceways in wet or dry location and in

90deg CWet locationsOverload 130deg CShort Circuit

MAXIMUM OPERATING VOLTAGE

3) Good resistance to most oils and

chemicals

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

accordance with NEC Article 3186) Available in VW-1 and non VW-1

UL-44

SPECIFICATIONS

Chapter 9

250deg C

1) Smaller overall diameter for easier

HOW TO ORDER

National Electrical Code References

Article 310

VULCANELreg XLPE cable type XHHW-2600 volts size and length

Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL

TYPE XHHW-2 600 VOLTS

reg XLPE CABLE

2 1

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch Mils inch lbMft

manufacturing tolerances

14 7 41 007 30 013 19

12 7 65 009 30 015 48

10 7 103 011 30 017 42

8 7 165 015 45 024 71

6 7 262 018 45 027 98

4 7 417 023 45 032 153

2 7 663 029 45 038 241

10 19 1060 037 55 048 378

20 19 1330 041 55 052 446

30 19 1680 047 55 058 556

40 19 2110 052 55 063 697

250 37 057 65 070 851

300 37 062 65 075 997

350 37 067 65 080 1180

400 37 072 65 085 1306

500 37 080 65 093 1662

600 61 088 80 104 1974

750 61 098 80 115 2450

1000 61 114 80 130 3240

Dimension and weights shown are nominal unless otherwise indicated and subject to

13

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

APPLICATION

FEATURES

MAXIMUM OPERATING VOLTAGE

MAXIMUM CONDUCTOR TEMPERATURE

UL-44

SPECIFICATIONS

Chapter 9

HOW TO ORDER

National Electrical Code References

Article 310Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL S8000

XHHW or XHHW-2 600 VOLTS ALUMINUM

reg XLPE CABLE

manufacturing tolerances

Size Number Insulations Overall Netof Thickness Diameter Weight

AWGkcmilStrands Mils In LbMft

6 7 45 027 42

4 7 45 031 59

2 7 45 036 88

1 7 55 042 111

10 19 55 045 136

20 19 55 049 165

30 19 55 054 203

40 19 55 059 250

250 37 65 066 300

300 37 65 071 354

350 37 65 075 405

500 37 65 087 562

600 61 80 098 684

750 61 80 108 840

900 61 80 117 995

Dimension and weights shown are nominal unless otherwise indicated and subject to

2 13

1) Stranded compact class B AA-8000 series aluminum alloy soft conductor2) Separator tape3) Cross-linked polyethylene (XLPE) insulation type XHHW or XHHW-2

Branch-circuits and feeders conductors in low voltage for buildings schools auditoriums hospitals stadiums museums poultry farms etc Industrial and commercial buildings For use in cable trays or raceways in wet and dry locations

600 volts

Wet and dry continuousOverloadShort circuit

90 C130 C125 C

1) Easier pulling and greater conduit fill2) Good moisture resistance3) Excellent dielectrics properties4) Continuous 90 C operating temperature in wet or dry locations5) Suitable for use in cable trays (10 AWG and greater)6) VW-1 compliant7) Sunlight resistant insulatedRoHS compliant

APPROVALS

Type XHHW or XHHW-2 UL listedType Rw90 or RWU90 upon special request

Vulcanel S8000 cable type XHHW or XHHW-2 RoHS CT-SR with stranded compact class B AA-8000 series aluminum alloy soft conductor size length and product number

reg

114

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANEL EPR ANTILLAMA CABLE

600 VOLTS

26ACSR01

DESCRIPTION

FEATURES

HOW TO ORDER

SPECIFICATIONSSPECIFICATIONS

3 2 1

1) Annealed coated or un-coated stranded class B copper conductor2) Ethylene propylene rubber (EPR) insulation3) Chlorosulfonated polyethylene (Hypalon) or chlorinated polyethylene(CPE) jacket

APPLICATION

Ideally suited for use in Electrical generating stations May be installed in free air all raceways or direct burial

MAXIMUM CONDUCTOR TEMPERATUREDry LocationsDry and Wet LocationsOverloadShort Circuit

90 C75 C130 C250 C

MAXIMUM OPERATING VOLTAGE600 Volts

1) Flame resistant Meets or exceeds requirements of IEEE 383 flame test2) Deformation resistant at high temperatures3) Excellent Flexibility at low temperature suitable for installation in sub-zero temperatures4) Extra tough mechanically rugged composite insulation and jacket construction6) Resistant to most oils and chemicals

ICEA S-95-658

VULCANEL EPR ANTILLAMA cable 600 volts size length National Electrical Code ReferencesAmpacities Article 31318-10Cable Trays Article 318

Dupont trade mark

reg reg

Size Number Conductor Insulation Jacket Overall Netof Diameter Thickness Thickness Diameter Weight

AWGkcmilStrands Inch mils mils inch lbMft

8 7 015 45 15 026 79

6 7 118 45 30 042 125

4 7 023 45 30 038 179

2 7 029 45 30 043 269

10 19 037 55 45 056 432

20 19 041 55 45 061 528

30 19 047 55 45 066 647

40 19 052 55 45 071 797

250 37 057 65 45 082 982

300 37 062 65 65 087 1146

352 37 067 65 65 092 1351

400 37 072 65 65 097 1480

500 37 080 65 65 105 1782

600 61 088 80 65 116 2186

750 61 098 80 65 126 2685

1000 61 114 80 65 141 3410

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

reg reg

15

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

CODE SIZE STRAND OVERALL DIAMETER NET WEIGHT RUPTURE STRENGTH

Turkey 6 61 0198 503 36 54

Swan 4 61 0250 635 58 86

Swallow 3 61 0281 714 73 108

Sparrow 2 61 0316 803 91 136

Robin 1 61 0355 902 115 171

Raven 10 61 0398 1011 145 216

Quail 20 61 0447 1135 183 273

Pigeon 30 61 0502 1275 231 344

Penguin 40 61 0563 1430 291 433

Partridge 2668 267 0642 1631 366 544

Linnet 3364 267 0721 1831 162 688

Oriole 3364 307 0741 1882 525 782

Ibis 3975 267 0783 1989 545 811

Lark 3975 307 0806 2047 619 921

Hawk 4770 267 0858 2179 654 973

Hen 4770 307 0883 2243 743 1106

Heron 5000 307 0904 2296 781 1162

Dove 5565 267 0927 2355 765 1138

Eagle 5565 307 0953 2421 869 1293

Duck 6050 547 0953 2421 779 1159

Grosbeak 6360 267 0990 2515 872 1298

Starling 7155 267 1051 2670 986 1467

Crow 7155 547 1035 2629 918 1366

Drake 7950 267 1108 2814 1095 1629

Condor 7950 547 1093 2776 1021 1520

Canary 9000 547 1162 2951 1160 1726

Rail 9540 457 1165 2959 1076 1601

Bluejay 11130 457 1259 3198 1256 1869

11903

18608

23040

28575

35550

43875

53100

66825

84308

113175

141075

173250

163125

203175

195075

238500

247500

227250

279000

234000

252000

283500

261000

315000

281250

323370

258750

309870

WORD AWG or MCM ALSteel Inch mm Lbsmft kgkm lbs

manufacturing tolerances

Condumex can currently produce a wider

BARE ACSR CABLE

ALUMINUM CONDUCTOR STEEL REINFORCED

26ACSR01

DESCRIPTION

CONDUCTORS

Aluminum 1350 wire concentrically laid overa solid or stranded galvanized steel core

Mechanical design requirements5) Good corrosion resistance

3) High resistance to mechanical strength4) Wide variety of sizes available in long

lengths to suit both electrical and

fewer towers required

strength to permit the longest possiblespans

2) Minimum sag between supports with

1) Ideal combination of conductivity and

FEATURES

Code Word quantity required in weight

ACSR cable size Aluminum Association

HOW TO ORDER

Overhead transmission subtransmission

overhead electrical cables Messenger and

overhead lines Messenger cables to support

APPLICATION

and distribution systems Static wires to protect

power support conductor in catenary systems

for railroad electrification

SPECIFICATIONS

ASTM B498 Galvanized steel class A

ASTM B232 Conductor overall

SPECIFICATIONS

ASTM B230 Aluminum wires

MAXIMUM CONDUCTOR TEMPERATURE

Normal Operation 75 degC

116

Dimension and weights shown are nominal unless otherwise indicated and subject to

range of products then what is listedPlease contact us for other items

Grand Prairie Texas800-925-9473

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
Page 13: 5Power Cable Specs Set 2 - Condumex  · PDF fileCondumex Wire and Cable 2590 114th Street, ... Type Conductors Diameter Ampacity Weight AWG ... 6 19 26.2 0.18 30 6 0.26

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

ICEA-S-68-516

SPECIFICATIONS

three conductor cable voltage size andlength

Condumex Mining Cable EPR type SHD-GC

HOW TO ORDER

MINING CABLE EPR TYPE SHD-GC

THREE CONDUCTOR 5000 VOLTS

18SHD-GC01

with a nylon webbing provides a tough defense

round configuration

and Health Administration Approval No P-218-1-MSHA

by the Pennsylvania Department of Environmental

Resources Meets MSHA flame test requirements

6) Acceptance No P-218-1-MSHA by Mines Safety

5) CV-Cured extra-heavy-duty CPE reinforced

4) Prevulcanized thermosetting non-wicking fillers

mechanical resistant jacket

resistance outstanding corona resistance

high dielectric strength and chemical resistance

designed for flexibility and resistance to

FEATURES

2) Ground check conductor facilitates fail-safe

3) EPR insulation offers excellent heat and moisture

are used if necessary to obtain a substantially

1) Special tinned copper stranded conductors

fatigue resulting from bending and flexing

ground monitoring for maximum safety

Dimension and weights shown are nominal unless otherwise indicated and subject to

6 7x3029 020 110 10 8 156

4 7x4729 025 110 8 8 168

2 7x7429 031 110 6 8 187

1 7x3725 035 110 5 8 195

10 7x4725 039 110 4 8 208

20 7x6025 045 110 3 8 220

30 7x7525 050 110 2 8 236

40 19x3525 059 110 1 8 250

300 19x4925 069 120 10 8 281

350 19x5825 076 120 20 8 295

1675

1888

2322

2653

3068

3504

4206

5023

6371

7654

Size Number of Conductor Insulation Ground Ground OverallAWG Strands Diameter Thickness Size Check Size Diameterkcmil AWG inch mils AWG AWG inch

NetWeightlbmft

manufacturing tolerances

MAXIMUM CONDUCTOR TEMPERATURE

Normal continuous 90deg C130deg COverload

250deg CShort circuit

MAXIMUM OPERATING VOLTAGE

5000 volts

Trailing cable on ac mining equipment

where service conditions are severe andmaximum safety is mandatory such as

APPLICATION

power shovels and draglines in open-pit

mines quarries gantry cranes and slag

reclaiming Also used for medium voltage

distribution in underground mines where

frequent relocation is necessary

DESCRIPTION

1) Three flexible annealed tinned copper rope-lay stranded conductors

2) Extruded semi-conducting conductor shieldand ethylene propylene rubber (EPR) insulation

3) Color coded cottoncopper braid shield applied over semi-conducting tape

4) Two annealed tinned copper rope-lay strandedgrounding conductors

5) Annealed tinned copper rope-lay stranded

and covered with a yellow cotton braid

chlorinated polyethylene (CPE) jacket

6) Rubberized cotton binder tape7) Nylon web reinforced extra-heavy-duty

ground check conductor yellow EPR insulation

346 2 157

110

RoHS

5) Overall flame retardant PVC jacket

DESCRIPTION

XLP insulation3) Fillers (if required)

4) Binder tape over core

2) Cross-Linked polyethylene thermosetting

1) Annealed bare stranded compressed

Class B copper conductors

without grounding conductorVolts number and size of conductors with or

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet

lighting control signal and communication circuitsin cable trays raceways direct burial or on

HOW TO ORDER

Condumex Tray Cable Type TCXHHW 600

SPECIFICATIONS

UL-1277 amp UL-44

APPLICATION

most chemicals in accordance with the

MAXIMUM OPERATING VOLTAGE

National Electrical Code

or dry locations and in the presence of oil and

6) Acceptable for Class 1 Division 2 HazardousLocations applications

O5) PVC jacket is UL rated 90 C and listed OilResistant I

600 volts

MAXIMUM CONDUCTOR TEMPERATUREO 90 C

O130 C

FEATURES

OverloadNormal

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

National Electrical Code

BTU flame test)3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

tray cable use in accordance with the

3 145 2

POWER CABLE TYPE TC

XHHW 600 VOLTS

Size Number Ground Insulation Jacket Overall Netof Conductor Thickness Thickness Diameter Weight

AWGkcmilConductors AWG mils mils inch lbMft

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 3 10 45 60 066 310

6 3 8 45 60 074 448

4 3 8 45 80 088 659

2 3 6 45 80 103 968

10 3 6 55 80 121 1428

20 3 4 55 80 131 1735

30 3 4 55 80 142 2150

40 3 4 55 80 154 3620

250 3 4 65 110 175 3190

350 3 3 65 110 196 4305

500 3 2 65 110 225 5940

8 4 10 45 60 073 385

6 4 8 45 80 083 568

4 4 8 45 80 097 832

2 4 6 45 80 112 1230

10 4 6 5 80 134 1825

20 4 4 55 80 145 2212

30 4 4 55 80 157 2751

40 4 4 55 110 177 3462

250 4 4 65 110 198 4097

350 4 3 65 110 217 5542

500 4 2 65 110 249 7690

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

111

7) ldquoERrdquo Listed per UL 1277

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

National Electrical Code References

Product Article 310 Table 310-13

Ampacities Article 310-15

HOW TO ORDER

CONDUMEX type RHH-RHW-USE-2

XLPE 600 volts size length quantity

packaging

DESCRIPTION

polyethylene (XLPE) insualtion

1) Annealed bare stranded class B

conductor

2) Flame-retardant cross-linked

TYPE RHH-RHW-USE-2

COPPER XLPE 600 VOLTS

APPLICATION

May be installed in free air all raceways or

underground service entrance cable

Type RHH 90deg C Dry and

temperatures

6) Stable electrical propoerties

UL-44 Standard for Rubber-Insulated

use in direct burial in industrial andcommercial application May be used as

7) Extremely tough

SPECIFICATIONS

4) Good resistance to most oils and

3) UL approved as VW-1 (RHH or RHW)

chemicals5) Suitable for installation in sub-zero

2) UL listed as types RHH or RHW or USE forresistant insulation

damp locations

ICEA S-66-524 Standard for Cross-Linked

Type RHW or 75deg C Dry and

use in accordance with the National

Electrical Code

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

MAXIMUM OPERATING VOLTAGE

USE wet locatinons

1) Flame retardant moisture and heat

FEATURES

Wires and Cables

Polyethylene Insualted Wire and Cable

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch mils inch lbMft

8 7 165 015 60 027 73

6 7 262 018 60 031 108

4 7 417 022 60 035 161

2 7 663 028 60 041 245

10 19 106 036 80 053 392

20 19 133 041 80 058 485

30 19 168 046 80 063 600

40 19 211 051 80 069 746

250 37 056 95 076 887

300 37 061 95 082 1052

350 37 066 95 087 1216

400 37 071 95 092 1380

500 37 079 95 099 1708

600 61 087 110 111 2055

750 61 097 110 120 2542

1000 61 112 110 136 3353

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

11 112

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

copper conductor

2) Cross-linked polyethylene (XLPE)

insulation

compressed (6 AWG-1000 MCM)

1) Annealed bare stranded class B

concentric round (14-8 AWG)

APPLICATION

Power or control circuits in recognized

switchboard wiring

Dry locations 90deg C

presence of oil Also suitable as

designs

temperatures

4) Suitable for installation in sub-zero

pulling and greater conduit fill

5) Optical For CT use marking for use in

cable trays Sunlight resistant in

FEATURES

2) Good moisture resistance

raceways in wet or dry location and in

90deg CWet locationsOverload 130deg CShort Circuit

MAXIMUM OPERATING VOLTAGE

3) Good resistance to most oils and

chemicals

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

accordance with NEC Article 3186) Available in VW-1 and non VW-1

UL-44

SPECIFICATIONS

Chapter 9

250deg C

1) Smaller overall diameter for easier

HOW TO ORDER

National Electrical Code References

Article 310

VULCANELreg XLPE cable type XHHW-2600 volts size and length

Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL

TYPE XHHW-2 600 VOLTS

reg XLPE CABLE

2 1

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch Mils inch lbMft

manufacturing tolerances

14 7 41 007 30 013 19

12 7 65 009 30 015 48

10 7 103 011 30 017 42

8 7 165 015 45 024 71

6 7 262 018 45 027 98

4 7 417 023 45 032 153

2 7 663 029 45 038 241

10 19 1060 037 55 048 378

20 19 1330 041 55 052 446

30 19 1680 047 55 058 556

40 19 2110 052 55 063 697

250 37 057 65 070 851

300 37 062 65 075 997

350 37 067 65 080 1180

400 37 072 65 085 1306

500 37 080 65 093 1662

600 61 088 80 104 1974

750 61 098 80 115 2450

1000 61 114 80 130 3240

Dimension and weights shown are nominal unless otherwise indicated and subject to

13

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

APPLICATION

FEATURES

MAXIMUM OPERATING VOLTAGE

MAXIMUM CONDUCTOR TEMPERATURE

UL-44

SPECIFICATIONS

Chapter 9

HOW TO ORDER

National Electrical Code References

Article 310Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL S8000

XHHW or XHHW-2 600 VOLTS ALUMINUM

reg XLPE CABLE

manufacturing tolerances

Size Number Insulations Overall Netof Thickness Diameter Weight

AWGkcmilStrands Mils In LbMft

6 7 45 027 42

4 7 45 031 59

2 7 45 036 88

1 7 55 042 111

10 19 55 045 136

20 19 55 049 165

30 19 55 054 203

40 19 55 059 250

250 37 65 066 300

300 37 65 071 354

350 37 65 075 405

500 37 65 087 562

600 61 80 098 684

750 61 80 108 840

900 61 80 117 995

Dimension and weights shown are nominal unless otherwise indicated and subject to

2 13

1) Stranded compact class B AA-8000 series aluminum alloy soft conductor2) Separator tape3) Cross-linked polyethylene (XLPE) insulation type XHHW or XHHW-2

Branch-circuits and feeders conductors in low voltage for buildings schools auditoriums hospitals stadiums museums poultry farms etc Industrial and commercial buildings For use in cable trays or raceways in wet and dry locations

600 volts

Wet and dry continuousOverloadShort circuit

90 C130 C125 C

1) Easier pulling and greater conduit fill2) Good moisture resistance3) Excellent dielectrics properties4) Continuous 90 C operating temperature in wet or dry locations5) Suitable for use in cable trays (10 AWG and greater)6) VW-1 compliant7) Sunlight resistant insulatedRoHS compliant

APPROVALS

Type XHHW or XHHW-2 UL listedType Rw90 or RWU90 upon special request

Vulcanel S8000 cable type XHHW or XHHW-2 RoHS CT-SR with stranded compact class B AA-8000 series aluminum alloy soft conductor size length and product number

reg

114

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANEL EPR ANTILLAMA CABLE

600 VOLTS

26ACSR01

DESCRIPTION

FEATURES

HOW TO ORDER

SPECIFICATIONSSPECIFICATIONS

3 2 1

1) Annealed coated or un-coated stranded class B copper conductor2) Ethylene propylene rubber (EPR) insulation3) Chlorosulfonated polyethylene (Hypalon) or chlorinated polyethylene(CPE) jacket

APPLICATION

Ideally suited for use in Electrical generating stations May be installed in free air all raceways or direct burial

MAXIMUM CONDUCTOR TEMPERATUREDry LocationsDry and Wet LocationsOverloadShort Circuit

90 C75 C130 C250 C

MAXIMUM OPERATING VOLTAGE600 Volts

1) Flame resistant Meets or exceeds requirements of IEEE 383 flame test2) Deformation resistant at high temperatures3) Excellent Flexibility at low temperature suitable for installation in sub-zero temperatures4) Extra tough mechanically rugged composite insulation and jacket construction6) Resistant to most oils and chemicals

ICEA S-95-658

VULCANEL EPR ANTILLAMA cable 600 volts size length National Electrical Code ReferencesAmpacities Article 31318-10Cable Trays Article 318

Dupont trade mark

reg reg

Size Number Conductor Insulation Jacket Overall Netof Diameter Thickness Thickness Diameter Weight

AWGkcmilStrands Inch mils mils inch lbMft

8 7 015 45 15 026 79

6 7 118 45 30 042 125

4 7 023 45 30 038 179

2 7 029 45 30 043 269

10 19 037 55 45 056 432

20 19 041 55 45 061 528

30 19 047 55 45 066 647

40 19 052 55 45 071 797

250 37 057 65 45 082 982

300 37 062 65 65 087 1146

352 37 067 65 65 092 1351

400 37 072 65 65 097 1480

500 37 080 65 65 105 1782

600 61 088 80 65 116 2186

750 61 098 80 65 126 2685

1000 61 114 80 65 141 3410

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

reg reg

15

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

CODE SIZE STRAND OVERALL DIAMETER NET WEIGHT RUPTURE STRENGTH

Turkey 6 61 0198 503 36 54

Swan 4 61 0250 635 58 86

Swallow 3 61 0281 714 73 108

Sparrow 2 61 0316 803 91 136

Robin 1 61 0355 902 115 171

Raven 10 61 0398 1011 145 216

Quail 20 61 0447 1135 183 273

Pigeon 30 61 0502 1275 231 344

Penguin 40 61 0563 1430 291 433

Partridge 2668 267 0642 1631 366 544

Linnet 3364 267 0721 1831 162 688

Oriole 3364 307 0741 1882 525 782

Ibis 3975 267 0783 1989 545 811

Lark 3975 307 0806 2047 619 921

Hawk 4770 267 0858 2179 654 973

Hen 4770 307 0883 2243 743 1106

Heron 5000 307 0904 2296 781 1162

Dove 5565 267 0927 2355 765 1138

Eagle 5565 307 0953 2421 869 1293

Duck 6050 547 0953 2421 779 1159

Grosbeak 6360 267 0990 2515 872 1298

Starling 7155 267 1051 2670 986 1467

Crow 7155 547 1035 2629 918 1366

Drake 7950 267 1108 2814 1095 1629

Condor 7950 547 1093 2776 1021 1520

Canary 9000 547 1162 2951 1160 1726

Rail 9540 457 1165 2959 1076 1601

Bluejay 11130 457 1259 3198 1256 1869

11903

18608

23040

28575

35550

43875

53100

66825

84308

113175

141075

173250

163125

203175

195075

238500

247500

227250

279000

234000

252000

283500

261000

315000

281250

323370

258750

309870

WORD AWG or MCM ALSteel Inch mm Lbsmft kgkm lbs

manufacturing tolerances

Condumex can currently produce a wider

BARE ACSR CABLE

ALUMINUM CONDUCTOR STEEL REINFORCED

26ACSR01

DESCRIPTION

CONDUCTORS

Aluminum 1350 wire concentrically laid overa solid or stranded galvanized steel core

Mechanical design requirements5) Good corrosion resistance

3) High resistance to mechanical strength4) Wide variety of sizes available in long

lengths to suit both electrical and

fewer towers required

strength to permit the longest possiblespans

2) Minimum sag between supports with

1) Ideal combination of conductivity and

FEATURES

Code Word quantity required in weight

ACSR cable size Aluminum Association

HOW TO ORDER

Overhead transmission subtransmission

overhead electrical cables Messenger and

overhead lines Messenger cables to support

APPLICATION

and distribution systems Static wires to protect

power support conductor in catenary systems

for railroad electrification

SPECIFICATIONS

ASTM B498 Galvanized steel class A

ASTM B232 Conductor overall

SPECIFICATIONS

ASTM B230 Aluminum wires

MAXIMUM CONDUCTOR TEMPERATURE

Normal Operation 75 degC

116

Dimension and weights shown are nominal unless otherwise indicated and subject to

range of products then what is listedPlease contact us for other items

Grand Prairie Texas800-925-9473

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
Page 14: 5Power Cable Specs Set 2 - Condumex  · PDF fileCondumex Wire and Cable 2590 114th Street, ... Type Conductors Diameter Ampacity Weight AWG ... 6 19 26.2 0.18 30 6 0.26

5) Overall flame retardant PVC jacket

DESCRIPTION

XLP insulation3) Fillers (if required)

4) Binder tape over core

2) Cross-Linked polyethylene thermosetting

1) Annealed bare stranded compressed

Class B copper conductors

without grounding conductorVolts number and size of conductors with or

Condumex Type TC cable may be used for power

messenger Type TC cable may be used in wet

lighting control signal and communication circuitsin cable trays raceways direct burial or on

HOW TO ORDER

Condumex Tray Cable Type TCXHHW 600

SPECIFICATIONS

UL-1277 amp UL-44

APPLICATION

most chemicals in accordance with the

MAXIMUM OPERATING VOLTAGE

National Electrical Code

or dry locations and in the presence of oil and

6) Acceptable for Class 1 Division 2 HazardousLocations applications

O5) PVC jacket is UL rated 90 C and listed OilResistant I

600 volts

MAXIMUM CONDUCTOR TEMPERATUREO 90 C

O130 C

FEATURES

OverloadNormal

1) UL listed for direct burial2) Flame retardant (passes UL 1277 70000

National Electrical Code

BTU flame test)3) Sunlight resistant can be installed outdoors4) UL listed as Type TC for power and control

tray cable use in accordance with the

3 145 2

POWER CABLE TYPE TC

XHHW 600 VOLTS

Size Number Ground Insulation Jacket Overall Netof Conductor Thickness Thickness Diameter Weight

AWGkcmilConductors AWG mils mils inch lbMft

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

8 3 10 45 60 066 310

6 3 8 45 60 074 448

4 3 8 45 80 088 659

2 3 6 45 80 103 968

10 3 6 55 80 121 1428

20 3 4 55 80 131 1735

30 3 4 55 80 142 2150

40 3 4 55 80 154 3620

250 3 4 65 110 175 3190

350 3 3 65 110 196 4305

500 3 2 65 110 225 5940

8 4 10 45 60 073 385

6 4 8 45 80 083 568

4 4 8 45 80 097 832

2 4 6 45 80 112 1230

10 4 6 5 80 134 1825

20 4 4 55 80 145 2212

30 4 4 55 80 157 2751

40 4 4 55 110 177 3462

250 4 4 65 110 198 4097

350 4 3 65 110 217 5542

500 4 2 65 110 249 7690

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

111

7) ldquoERrdquo Listed per UL 1277

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

National Electrical Code References

Product Article 310 Table 310-13

Ampacities Article 310-15

HOW TO ORDER

CONDUMEX type RHH-RHW-USE-2

XLPE 600 volts size length quantity

packaging

DESCRIPTION

polyethylene (XLPE) insualtion

1) Annealed bare stranded class B

conductor

2) Flame-retardant cross-linked

TYPE RHH-RHW-USE-2

COPPER XLPE 600 VOLTS

APPLICATION

May be installed in free air all raceways or

underground service entrance cable

Type RHH 90deg C Dry and

temperatures

6) Stable electrical propoerties

UL-44 Standard for Rubber-Insulated

use in direct burial in industrial andcommercial application May be used as

7) Extremely tough

SPECIFICATIONS

4) Good resistance to most oils and

3) UL approved as VW-1 (RHH or RHW)

chemicals5) Suitable for installation in sub-zero

2) UL listed as types RHH or RHW or USE forresistant insulation

damp locations

ICEA S-66-524 Standard for Cross-Linked

Type RHW or 75deg C Dry and

use in accordance with the National

Electrical Code

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

MAXIMUM OPERATING VOLTAGE

USE wet locatinons

1) Flame retardant moisture and heat

FEATURES

Wires and Cables

Polyethylene Insualted Wire and Cable

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch mils inch lbMft

8 7 165 015 60 027 73

6 7 262 018 60 031 108

4 7 417 022 60 035 161

2 7 663 028 60 041 245

10 19 106 036 80 053 392

20 19 133 041 80 058 485

30 19 168 046 80 063 600

40 19 211 051 80 069 746

250 37 056 95 076 887

300 37 061 95 082 1052

350 37 066 95 087 1216

400 37 071 95 092 1380

500 37 079 95 099 1708

600 61 087 110 111 2055

750 61 097 110 120 2542

1000 61 112 110 136 3353

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

11 112

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

copper conductor

2) Cross-linked polyethylene (XLPE)

insulation

compressed (6 AWG-1000 MCM)

1) Annealed bare stranded class B

concentric round (14-8 AWG)

APPLICATION

Power or control circuits in recognized

switchboard wiring

Dry locations 90deg C

presence of oil Also suitable as

designs

temperatures

4) Suitable for installation in sub-zero

pulling and greater conduit fill

5) Optical For CT use marking for use in

cable trays Sunlight resistant in

FEATURES

2) Good moisture resistance

raceways in wet or dry location and in

90deg CWet locationsOverload 130deg CShort Circuit

MAXIMUM OPERATING VOLTAGE

3) Good resistance to most oils and

chemicals

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

accordance with NEC Article 3186) Available in VW-1 and non VW-1

UL-44

SPECIFICATIONS

Chapter 9

250deg C

1) Smaller overall diameter for easier

HOW TO ORDER

National Electrical Code References

Article 310

VULCANELreg XLPE cable type XHHW-2600 volts size and length

Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL

TYPE XHHW-2 600 VOLTS

reg XLPE CABLE

2 1

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch Mils inch lbMft

manufacturing tolerances

14 7 41 007 30 013 19

12 7 65 009 30 015 48

10 7 103 011 30 017 42

8 7 165 015 45 024 71

6 7 262 018 45 027 98

4 7 417 023 45 032 153

2 7 663 029 45 038 241

10 19 1060 037 55 048 378

20 19 1330 041 55 052 446

30 19 1680 047 55 058 556

40 19 2110 052 55 063 697

250 37 057 65 070 851

300 37 062 65 075 997

350 37 067 65 080 1180

400 37 072 65 085 1306

500 37 080 65 093 1662

600 61 088 80 104 1974

750 61 098 80 115 2450

1000 61 114 80 130 3240

Dimension and weights shown are nominal unless otherwise indicated and subject to

13

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

APPLICATION

FEATURES

MAXIMUM OPERATING VOLTAGE

MAXIMUM CONDUCTOR TEMPERATURE

UL-44

SPECIFICATIONS

Chapter 9

HOW TO ORDER

National Electrical Code References

Article 310Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL S8000

XHHW or XHHW-2 600 VOLTS ALUMINUM

reg XLPE CABLE

manufacturing tolerances

Size Number Insulations Overall Netof Thickness Diameter Weight

AWGkcmilStrands Mils In LbMft

6 7 45 027 42

4 7 45 031 59

2 7 45 036 88

1 7 55 042 111

10 19 55 045 136

20 19 55 049 165

30 19 55 054 203

40 19 55 059 250

250 37 65 066 300

300 37 65 071 354

350 37 65 075 405

500 37 65 087 562

600 61 80 098 684

750 61 80 108 840

900 61 80 117 995

Dimension and weights shown are nominal unless otherwise indicated and subject to

2 13

1) Stranded compact class B AA-8000 series aluminum alloy soft conductor2) Separator tape3) Cross-linked polyethylene (XLPE) insulation type XHHW or XHHW-2

Branch-circuits and feeders conductors in low voltage for buildings schools auditoriums hospitals stadiums museums poultry farms etc Industrial and commercial buildings For use in cable trays or raceways in wet and dry locations

600 volts

Wet and dry continuousOverloadShort circuit

90 C130 C125 C

1) Easier pulling and greater conduit fill2) Good moisture resistance3) Excellent dielectrics properties4) Continuous 90 C operating temperature in wet or dry locations5) Suitable for use in cable trays (10 AWG and greater)6) VW-1 compliant7) Sunlight resistant insulatedRoHS compliant

APPROVALS

Type XHHW or XHHW-2 UL listedType Rw90 or RWU90 upon special request

Vulcanel S8000 cable type XHHW or XHHW-2 RoHS CT-SR with stranded compact class B AA-8000 series aluminum alloy soft conductor size length and product number

reg

114

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANEL EPR ANTILLAMA CABLE

600 VOLTS

26ACSR01

DESCRIPTION

FEATURES

HOW TO ORDER

SPECIFICATIONSSPECIFICATIONS

3 2 1

1) Annealed coated or un-coated stranded class B copper conductor2) Ethylene propylene rubber (EPR) insulation3) Chlorosulfonated polyethylene (Hypalon) or chlorinated polyethylene(CPE) jacket

APPLICATION

Ideally suited for use in Electrical generating stations May be installed in free air all raceways or direct burial

MAXIMUM CONDUCTOR TEMPERATUREDry LocationsDry and Wet LocationsOverloadShort Circuit

90 C75 C130 C250 C

MAXIMUM OPERATING VOLTAGE600 Volts

1) Flame resistant Meets or exceeds requirements of IEEE 383 flame test2) Deformation resistant at high temperatures3) Excellent Flexibility at low temperature suitable for installation in sub-zero temperatures4) Extra tough mechanically rugged composite insulation and jacket construction6) Resistant to most oils and chemicals

ICEA S-95-658

VULCANEL EPR ANTILLAMA cable 600 volts size length National Electrical Code ReferencesAmpacities Article 31318-10Cable Trays Article 318

Dupont trade mark

reg reg

Size Number Conductor Insulation Jacket Overall Netof Diameter Thickness Thickness Diameter Weight

AWGkcmilStrands Inch mils mils inch lbMft

8 7 015 45 15 026 79

6 7 118 45 30 042 125

4 7 023 45 30 038 179

2 7 029 45 30 043 269

10 19 037 55 45 056 432

20 19 041 55 45 061 528

30 19 047 55 45 066 647

40 19 052 55 45 071 797

250 37 057 65 45 082 982

300 37 062 65 65 087 1146

352 37 067 65 65 092 1351

400 37 072 65 65 097 1480

500 37 080 65 65 105 1782

600 61 088 80 65 116 2186

750 61 098 80 65 126 2685

1000 61 114 80 65 141 3410

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

reg reg

15

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

CODE SIZE STRAND OVERALL DIAMETER NET WEIGHT RUPTURE STRENGTH

Turkey 6 61 0198 503 36 54

Swan 4 61 0250 635 58 86

Swallow 3 61 0281 714 73 108

Sparrow 2 61 0316 803 91 136

Robin 1 61 0355 902 115 171

Raven 10 61 0398 1011 145 216

Quail 20 61 0447 1135 183 273

Pigeon 30 61 0502 1275 231 344

Penguin 40 61 0563 1430 291 433

Partridge 2668 267 0642 1631 366 544

Linnet 3364 267 0721 1831 162 688

Oriole 3364 307 0741 1882 525 782

Ibis 3975 267 0783 1989 545 811

Lark 3975 307 0806 2047 619 921

Hawk 4770 267 0858 2179 654 973

Hen 4770 307 0883 2243 743 1106

Heron 5000 307 0904 2296 781 1162

Dove 5565 267 0927 2355 765 1138

Eagle 5565 307 0953 2421 869 1293

Duck 6050 547 0953 2421 779 1159

Grosbeak 6360 267 0990 2515 872 1298

Starling 7155 267 1051 2670 986 1467

Crow 7155 547 1035 2629 918 1366

Drake 7950 267 1108 2814 1095 1629

Condor 7950 547 1093 2776 1021 1520

Canary 9000 547 1162 2951 1160 1726

Rail 9540 457 1165 2959 1076 1601

Bluejay 11130 457 1259 3198 1256 1869

11903

18608

23040

28575

35550

43875

53100

66825

84308

113175

141075

173250

163125

203175

195075

238500

247500

227250

279000

234000

252000

283500

261000

315000

281250

323370

258750

309870

WORD AWG or MCM ALSteel Inch mm Lbsmft kgkm lbs

manufacturing tolerances

Condumex can currently produce a wider

BARE ACSR CABLE

ALUMINUM CONDUCTOR STEEL REINFORCED

26ACSR01

DESCRIPTION

CONDUCTORS

Aluminum 1350 wire concentrically laid overa solid or stranded galvanized steel core

Mechanical design requirements5) Good corrosion resistance

3) High resistance to mechanical strength4) Wide variety of sizes available in long

lengths to suit both electrical and

fewer towers required

strength to permit the longest possiblespans

2) Minimum sag between supports with

1) Ideal combination of conductivity and

FEATURES

Code Word quantity required in weight

ACSR cable size Aluminum Association

HOW TO ORDER

Overhead transmission subtransmission

overhead electrical cables Messenger and

overhead lines Messenger cables to support

APPLICATION

and distribution systems Static wires to protect

power support conductor in catenary systems

for railroad electrification

SPECIFICATIONS

ASTM B498 Galvanized steel class A

ASTM B232 Conductor overall

SPECIFICATIONS

ASTM B230 Aluminum wires

MAXIMUM CONDUCTOR TEMPERATURE

Normal Operation 75 degC

116

Dimension and weights shown are nominal unless otherwise indicated and subject to

range of products then what is listedPlease contact us for other items

Grand Prairie Texas800-925-9473

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
Page 15: 5Power Cable Specs Set 2 - Condumex  · PDF fileCondumex Wire and Cable 2590 114th Street, ... Type Conductors Diameter Ampacity Weight AWG ... 6 19 26.2 0.18 30 6 0.26

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

National Electrical Code References

Product Article 310 Table 310-13

Ampacities Article 310-15

HOW TO ORDER

CONDUMEX type RHH-RHW-USE-2

XLPE 600 volts size length quantity

packaging

DESCRIPTION

polyethylene (XLPE) insualtion

1) Annealed bare stranded class B

conductor

2) Flame-retardant cross-linked

TYPE RHH-RHW-USE-2

COPPER XLPE 600 VOLTS

APPLICATION

May be installed in free air all raceways or

underground service entrance cable

Type RHH 90deg C Dry and

temperatures

6) Stable electrical propoerties

UL-44 Standard for Rubber-Insulated

use in direct burial in industrial andcommercial application May be used as

7) Extremely tough

SPECIFICATIONS

4) Good resistance to most oils and

3) UL approved as VW-1 (RHH or RHW)

chemicals5) Suitable for installation in sub-zero

2) UL listed as types RHH or RHW or USE forresistant insulation

damp locations

ICEA S-66-524 Standard for Cross-Linked

Type RHW or 75deg C Dry and

use in accordance with the National

Electrical Code

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

MAXIMUM OPERATING VOLTAGE

USE wet locatinons

1) Flame retardant moisture and heat

FEATURES

Wires and Cables

Polyethylene Insualted Wire and Cable

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch mils inch lbMft

8 7 165 015 60 027 73

6 7 262 018 60 031 108

4 7 417 022 60 035 161

2 7 663 028 60 041 245

10 19 106 036 80 053 392

20 19 133 041 80 058 485

30 19 168 046 80 063 600

40 19 211 051 80 069 746

250 37 056 95 076 887

300 37 061 95 082 1052

350 37 066 95 087 1216

400 37 071 95 092 1380

500 37 079 95 099 1708

600 61 087 110 111 2055

750 61 097 110 120 2542

1000 61 112 110 136 3353

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

11 112

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

copper conductor

2) Cross-linked polyethylene (XLPE)

insulation

compressed (6 AWG-1000 MCM)

1) Annealed bare stranded class B

concentric round (14-8 AWG)

APPLICATION

Power or control circuits in recognized

switchboard wiring

Dry locations 90deg C

presence of oil Also suitable as

designs

temperatures

4) Suitable for installation in sub-zero

pulling and greater conduit fill

5) Optical For CT use marking for use in

cable trays Sunlight resistant in

FEATURES

2) Good moisture resistance

raceways in wet or dry location and in

90deg CWet locationsOverload 130deg CShort Circuit

MAXIMUM OPERATING VOLTAGE

3) Good resistance to most oils and

chemicals

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

accordance with NEC Article 3186) Available in VW-1 and non VW-1

UL-44

SPECIFICATIONS

Chapter 9

250deg C

1) Smaller overall diameter for easier

HOW TO ORDER

National Electrical Code References

Article 310

VULCANELreg XLPE cable type XHHW-2600 volts size and length

Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL

TYPE XHHW-2 600 VOLTS

reg XLPE CABLE

2 1

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch Mils inch lbMft

manufacturing tolerances

14 7 41 007 30 013 19

12 7 65 009 30 015 48

10 7 103 011 30 017 42

8 7 165 015 45 024 71

6 7 262 018 45 027 98

4 7 417 023 45 032 153

2 7 663 029 45 038 241

10 19 1060 037 55 048 378

20 19 1330 041 55 052 446

30 19 1680 047 55 058 556

40 19 2110 052 55 063 697

250 37 057 65 070 851

300 37 062 65 075 997

350 37 067 65 080 1180

400 37 072 65 085 1306

500 37 080 65 093 1662

600 61 088 80 104 1974

750 61 098 80 115 2450

1000 61 114 80 130 3240

Dimension and weights shown are nominal unless otherwise indicated and subject to

13

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

APPLICATION

FEATURES

MAXIMUM OPERATING VOLTAGE

MAXIMUM CONDUCTOR TEMPERATURE

UL-44

SPECIFICATIONS

Chapter 9

HOW TO ORDER

National Electrical Code References

Article 310Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL S8000

XHHW or XHHW-2 600 VOLTS ALUMINUM

reg XLPE CABLE

manufacturing tolerances

Size Number Insulations Overall Netof Thickness Diameter Weight

AWGkcmilStrands Mils In LbMft

6 7 45 027 42

4 7 45 031 59

2 7 45 036 88

1 7 55 042 111

10 19 55 045 136

20 19 55 049 165

30 19 55 054 203

40 19 55 059 250

250 37 65 066 300

300 37 65 071 354

350 37 65 075 405

500 37 65 087 562

600 61 80 098 684

750 61 80 108 840

900 61 80 117 995

Dimension and weights shown are nominal unless otherwise indicated and subject to

2 13

1) Stranded compact class B AA-8000 series aluminum alloy soft conductor2) Separator tape3) Cross-linked polyethylene (XLPE) insulation type XHHW or XHHW-2

Branch-circuits and feeders conductors in low voltage for buildings schools auditoriums hospitals stadiums museums poultry farms etc Industrial and commercial buildings For use in cable trays or raceways in wet and dry locations

600 volts

Wet and dry continuousOverloadShort circuit

90 C130 C125 C

1) Easier pulling and greater conduit fill2) Good moisture resistance3) Excellent dielectrics properties4) Continuous 90 C operating temperature in wet or dry locations5) Suitable for use in cable trays (10 AWG and greater)6) VW-1 compliant7) Sunlight resistant insulatedRoHS compliant

APPROVALS

Type XHHW or XHHW-2 UL listedType Rw90 or RWU90 upon special request

Vulcanel S8000 cable type XHHW or XHHW-2 RoHS CT-SR with stranded compact class B AA-8000 series aluminum alloy soft conductor size length and product number

reg

114

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANEL EPR ANTILLAMA CABLE

600 VOLTS

26ACSR01

DESCRIPTION

FEATURES

HOW TO ORDER

SPECIFICATIONSSPECIFICATIONS

3 2 1

1) Annealed coated or un-coated stranded class B copper conductor2) Ethylene propylene rubber (EPR) insulation3) Chlorosulfonated polyethylene (Hypalon) or chlorinated polyethylene(CPE) jacket

APPLICATION

Ideally suited for use in Electrical generating stations May be installed in free air all raceways or direct burial

MAXIMUM CONDUCTOR TEMPERATUREDry LocationsDry and Wet LocationsOverloadShort Circuit

90 C75 C130 C250 C

MAXIMUM OPERATING VOLTAGE600 Volts

1) Flame resistant Meets or exceeds requirements of IEEE 383 flame test2) Deformation resistant at high temperatures3) Excellent Flexibility at low temperature suitable for installation in sub-zero temperatures4) Extra tough mechanically rugged composite insulation and jacket construction6) Resistant to most oils and chemicals

ICEA S-95-658

VULCANEL EPR ANTILLAMA cable 600 volts size length National Electrical Code ReferencesAmpacities Article 31318-10Cable Trays Article 318

Dupont trade mark

reg reg

Size Number Conductor Insulation Jacket Overall Netof Diameter Thickness Thickness Diameter Weight

AWGkcmilStrands Inch mils mils inch lbMft

8 7 015 45 15 026 79

6 7 118 45 30 042 125

4 7 023 45 30 038 179

2 7 029 45 30 043 269

10 19 037 55 45 056 432

20 19 041 55 45 061 528

30 19 047 55 45 066 647

40 19 052 55 45 071 797

250 37 057 65 45 082 982

300 37 062 65 65 087 1146

352 37 067 65 65 092 1351

400 37 072 65 65 097 1480

500 37 080 65 65 105 1782

600 61 088 80 65 116 2186

750 61 098 80 65 126 2685

1000 61 114 80 65 141 3410

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

reg reg

15

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

CODE SIZE STRAND OVERALL DIAMETER NET WEIGHT RUPTURE STRENGTH

Turkey 6 61 0198 503 36 54

Swan 4 61 0250 635 58 86

Swallow 3 61 0281 714 73 108

Sparrow 2 61 0316 803 91 136

Robin 1 61 0355 902 115 171

Raven 10 61 0398 1011 145 216

Quail 20 61 0447 1135 183 273

Pigeon 30 61 0502 1275 231 344

Penguin 40 61 0563 1430 291 433

Partridge 2668 267 0642 1631 366 544

Linnet 3364 267 0721 1831 162 688

Oriole 3364 307 0741 1882 525 782

Ibis 3975 267 0783 1989 545 811

Lark 3975 307 0806 2047 619 921

Hawk 4770 267 0858 2179 654 973

Hen 4770 307 0883 2243 743 1106

Heron 5000 307 0904 2296 781 1162

Dove 5565 267 0927 2355 765 1138

Eagle 5565 307 0953 2421 869 1293

Duck 6050 547 0953 2421 779 1159

Grosbeak 6360 267 0990 2515 872 1298

Starling 7155 267 1051 2670 986 1467

Crow 7155 547 1035 2629 918 1366

Drake 7950 267 1108 2814 1095 1629

Condor 7950 547 1093 2776 1021 1520

Canary 9000 547 1162 2951 1160 1726

Rail 9540 457 1165 2959 1076 1601

Bluejay 11130 457 1259 3198 1256 1869

11903

18608

23040

28575

35550

43875

53100

66825

84308

113175

141075

173250

163125

203175

195075

238500

247500

227250

279000

234000

252000

283500

261000

315000

281250

323370

258750

309870

WORD AWG or MCM ALSteel Inch mm Lbsmft kgkm lbs

manufacturing tolerances

Condumex can currently produce a wider

BARE ACSR CABLE

ALUMINUM CONDUCTOR STEEL REINFORCED

26ACSR01

DESCRIPTION

CONDUCTORS

Aluminum 1350 wire concentrically laid overa solid or stranded galvanized steel core

Mechanical design requirements5) Good corrosion resistance

3) High resistance to mechanical strength4) Wide variety of sizes available in long

lengths to suit both electrical and

fewer towers required

strength to permit the longest possiblespans

2) Minimum sag between supports with

1) Ideal combination of conductivity and

FEATURES

Code Word quantity required in weight

ACSR cable size Aluminum Association

HOW TO ORDER

Overhead transmission subtransmission

overhead electrical cables Messenger and

overhead lines Messenger cables to support

APPLICATION

and distribution systems Static wires to protect

power support conductor in catenary systems

for railroad electrification

SPECIFICATIONS

ASTM B498 Galvanized steel class A

ASTM B232 Conductor overall

SPECIFICATIONS

ASTM B230 Aluminum wires

MAXIMUM CONDUCTOR TEMPERATURE

Normal Operation 75 degC

116

Dimension and weights shown are nominal unless otherwise indicated and subject to

range of products then what is listedPlease contact us for other items

Grand Prairie Texas800-925-9473

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
Page 16: 5Power Cable Specs Set 2 - Condumex  · PDF fileCondumex Wire and Cable 2590 114th Street, ... Type Conductors Diameter Ampacity Weight AWG ... 6 19 26.2 0.18 30 6 0.26

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

copper conductor

2) Cross-linked polyethylene (XLPE)

insulation

compressed (6 AWG-1000 MCM)

1) Annealed bare stranded class B

concentric round (14-8 AWG)

APPLICATION

Power or control circuits in recognized

switchboard wiring

Dry locations 90deg C

presence of oil Also suitable as

designs

temperatures

4) Suitable for installation in sub-zero

pulling and greater conduit fill

5) Optical For CT use marking for use in

cable trays Sunlight resistant in

FEATURES

2) Good moisture resistance

raceways in wet or dry location and in

90deg CWet locationsOverload 130deg CShort Circuit

MAXIMUM OPERATING VOLTAGE

3) Good resistance to most oils and

chemicals

MAXIMUM CONDUCTOR TEMPERATURE

600 volts

accordance with NEC Article 3186) Available in VW-1 and non VW-1

UL-44

SPECIFICATIONS

Chapter 9

250deg C

1) Smaller overall diameter for easier

HOW TO ORDER

National Electrical Code References

Article 310

VULCANELreg XLPE cable type XHHW-2600 volts size and length

Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL

TYPE XHHW-2 600 VOLTS

reg XLPE CABLE

2 1

Size Number Conductor Conductor Insulations Overall Netof Area Diameter Thickness Diameter Weight

AWGkcmilStrands kcmil inch Mils inch lbMft

manufacturing tolerances

14 7 41 007 30 013 19

12 7 65 009 30 015 48

10 7 103 011 30 017 42

8 7 165 015 45 024 71

6 7 262 018 45 027 98

4 7 417 023 45 032 153

2 7 663 029 45 038 241

10 19 1060 037 55 048 378

20 19 1330 041 55 052 446

30 19 1680 047 55 058 556

40 19 2110 052 55 063 697

250 37 057 65 070 851

300 37 062 65 075 997

350 37 067 65 080 1180

400 37 072 65 085 1306

500 37 080 65 093 1662

600 61 088 80 104 1974

750 61 098 80 115 2450

1000 61 114 80 130 3240

Dimension and weights shown are nominal unless otherwise indicated and subject to

13

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

APPLICATION

FEATURES

MAXIMUM OPERATING VOLTAGE

MAXIMUM CONDUCTOR TEMPERATURE

UL-44

SPECIFICATIONS

Chapter 9

HOW TO ORDER

National Electrical Code References

Article 310Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL S8000

XHHW or XHHW-2 600 VOLTS ALUMINUM

reg XLPE CABLE

manufacturing tolerances

Size Number Insulations Overall Netof Thickness Diameter Weight

AWGkcmilStrands Mils In LbMft

6 7 45 027 42

4 7 45 031 59

2 7 45 036 88

1 7 55 042 111

10 19 55 045 136

20 19 55 049 165

30 19 55 054 203

40 19 55 059 250

250 37 65 066 300

300 37 65 071 354

350 37 65 075 405

500 37 65 087 562

600 61 80 098 684

750 61 80 108 840

900 61 80 117 995

Dimension and weights shown are nominal unless otherwise indicated and subject to

2 13

1) Stranded compact class B AA-8000 series aluminum alloy soft conductor2) Separator tape3) Cross-linked polyethylene (XLPE) insulation type XHHW or XHHW-2

Branch-circuits and feeders conductors in low voltage for buildings schools auditoriums hospitals stadiums museums poultry farms etc Industrial and commercial buildings For use in cable trays or raceways in wet and dry locations

600 volts

Wet and dry continuousOverloadShort circuit

90 C130 C125 C

1) Easier pulling and greater conduit fill2) Good moisture resistance3) Excellent dielectrics properties4) Continuous 90 C operating temperature in wet or dry locations5) Suitable for use in cable trays (10 AWG and greater)6) VW-1 compliant7) Sunlight resistant insulatedRoHS compliant

APPROVALS

Type XHHW or XHHW-2 UL listedType Rw90 or RWU90 upon special request

Vulcanel S8000 cable type XHHW or XHHW-2 RoHS CT-SR with stranded compact class B AA-8000 series aluminum alloy soft conductor size length and product number

reg

114

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANEL EPR ANTILLAMA CABLE

600 VOLTS

26ACSR01

DESCRIPTION

FEATURES

HOW TO ORDER

SPECIFICATIONSSPECIFICATIONS

3 2 1

1) Annealed coated or un-coated stranded class B copper conductor2) Ethylene propylene rubber (EPR) insulation3) Chlorosulfonated polyethylene (Hypalon) or chlorinated polyethylene(CPE) jacket

APPLICATION

Ideally suited for use in Electrical generating stations May be installed in free air all raceways or direct burial

MAXIMUM CONDUCTOR TEMPERATUREDry LocationsDry and Wet LocationsOverloadShort Circuit

90 C75 C130 C250 C

MAXIMUM OPERATING VOLTAGE600 Volts

1) Flame resistant Meets or exceeds requirements of IEEE 383 flame test2) Deformation resistant at high temperatures3) Excellent Flexibility at low temperature suitable for installation in sub-zero temperatures4) Extra tough mechanically rugged composite insulation and jacket construction6) Resistant to most oils and chemicals

ICEA S-95-658

VULCANEL EPR ANTILLAMA cable 600 volts size length National Electrical Code ReferencesAmpacities Article 31318-10Cable Trays Article 318

Dupont trade mark

reg reg

Size Number Conductor Insulation Jacket Overall Netof Diameter Thickness Thickness Diameter Weight

AWGkcmilStrands Inch mils mils inch lbMft

8 7 015 45 15 026 79

6 7 118 45 30 042 125

4 7 023 45 30 038 179

2 7 029 45 30 043 269

10 19 037 55 45 056 432

20 19 041 55 45 061 528

30 19 047 55 45 066 647

40 19 052 55 45 071 797

250 37 057 65 45 082 982

300 37 062 65 65 087 1146

352 37 067 65 65 092 1351

400 37 072 65 65 097 1480

500 37 080 65 65 105 1782

600 61 088 80 65 116 2186

750 61 098 80 65 126 2685

1000 61 114 80 65 141 3410

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

reg reg

15

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

CODE SIZE STRAND OVERALL DIAMETER NET WEIGHT RUPTURE STRENGTH

Turkey 6 61 0198 503 36 54

Swan 4 61 0250 635 58 86

Swallow 3 61 0281 714 73 108

Sparrow 2 61 0316 803 91 136

Robin 1 61 0355 902 115 171

Raven 10 61 0398 1011 145 216

Quail 20 61 0447 1135 183 273

Pigeon 30 61 0502 1275 231 344

Penguin 40 61 0563 1430 291 433

Partridge 2668 267 0642 1631 366 544

Linnet 3364 267 0721 1831 162 688

Oriole 3364 307 0741 1882 525 782

Ibis 3975 267 0783 1989 545 811

Lark 3975 307 0806 2047 619 921

Hawk 4770 267 0858 2179 654 973

Hen 4770 307 0883 2243 743 1106

Heron 5000 307 0904 2296 781 1162

Dove 5565 267 0927 2355 765 1138

Eagle 5565 307 0953 2421 869 1293

Duck 6050 547 0953 2421 779 1159

Grosbeak 6360 267 0990 2515 872 1298

Starling 7155 267 1051 2670 986 1467

Crow 7155 547 1035 2629 918 1366

Drake 7950 267 1108 2814 1095 1629

Condor 7950 547 1093 2776 1021 1520

Canary 9000 547 1162 2951 1160 1726

Rail 9540 457 1165 2959 1076 1601

Bluejay 11130 457 1259 3198 1256 1869

11903

18608

23040

28575

35550

43875

53100

66825

84308

113175

141075

173250

163125

203175

195075

238500

247500

227250

279000

234000

252000

283500

261000

315000

281250

323370

258750

309870

WORD AWG or MCM ALSteel Inch mm Lbsmft kgkm lbs

manufacturing tolerances

Condumex can currently produce a wider

BARE ACSR CABLE

ALUMINUM CONDUCTOR STEEL REINFORCED

26ACSR01

DESCRIPTION

CONDUCTORS

Aluminum 1350 wire concentrically laid overa solid or stranded galvanized steel core

Mechanical design requirements5) Good corrosion resistance

3) High resistance to mechanical strength4) Wide variety of sizes available in long

lengths to suit both electrical and

fewer towers required

strength to permit the longest possiblespans

2) Minimum sag between supports with

1) Ideal combination of conductivity and

FEATURES

Code Word quantity required in weight

ACSR cable size Aluminum Association

HOW TO ORDER

Overhead transmission subtransmission

overhead electrical cables Messenger and

overhead lines Messenger cables to support

APPLICATION

and distribution systems Static wires to protect

power support conductor in catenary systems

for railroad electrification

SPECIFICATIONS

ASTM B498 Galvanized steel class A

ASTM B232 Conductor overall

SPECIFICATIONS

ASTM B230 Aluminum wires

MAXIMUM CONDUCTOR TEMPERATURE

Normal Operation 75 degC

116

Dimension and weights shown are nominal unless otherwise indicated and subject to

range of products then what is listedPlease contact us for other items

Grand Prairie Texas800-925-9473

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
Page 17: 5Power Cable Specs Set 2 - Condumex  · PDF fileCondumex Wire and Cable 2590 114th Street, ... Type Conductors Diameter Ampacity Weight AWG ... 6 19 26.2 0.18 30 6 0.26

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

DESCRIPTION

APPLICATION

FEATURES

MAXIMUM OPERATING VOLTAGE

MAXIMUM CONDUCTOR TEMPERATURE

UL-44

SPECIFICATIONS

Chapter 9

HOW TO ORDER

National Electrical Code References

Article 310Ampacities

Switchboard wiring

Conduit fill tables

Dupont trade mark

Article 384

VULCANEL S8000

XHHW or XHHW-2 600 VOLTS ALUMINUM

reg XLPE CABLE

manufacturing tolerances

Size Number Insulations Overall Netof Thickness Diameter Weight

AWGkcmilStrands Mils In LbMft

6 7 45 027 42

4 7 45 031 59

2 7 45 036 88

1 7 55 042 111

10 19 55 045 136

20 19 55 049 165

30 19 55 054 203

40 19 55 059 250

250 37 65 066 300

300 37 65 071 354

350 37 65 075 405

500 37 65 087 562

600 61 80 098 684

750 61 80 108 840

900 61 80 117 995

Dimension and weights shown are nominal unless otherwise indicated and subject to

2 13

1) Stranded compact class B AA-8000 series aluminum alloy soft conductor2) Separator tape3) Cross-linked polyethylene (XLPE) insulation type XHHW or XHHW-2

Branch-circuits and feeders conductors in low voltage for buildings schools auditoriums hospitals stadiums museums poultry farms etc Industrial and commercial buildings For use in cable trays or raceways in wet and dry locations

600 volts

Wet and dry continuousOverloadShort circuit

90 C130 C125 C

1) Easier pulling and greater conduit fill2) Good moisture resistance3) Excellent dielectrics properties4) Continuous 90 C operating temperature in wet or dry locations5) Suitable for use in cable trays (10 AWG and greater)6) VW-1 compliant7) Sunlight resistant insulatedRoHS compliant

APPROVALS

Type XHHW or XHHW-2 UL listedType Rw90 or RWU90 upon special request

Vulcanel S8000 cable type XHHW or XHHW-2 RoHS CT-SR with stranded compact class B AA-8000 series aluminum alloy soft conductor size length and product number

reg

114

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANEL EPR ANTILLAMA CABLE

600 VOLTS

26ACSR01

DESCRIPTION

FEATURES

HOW TO ORDER

SPECIFICATIONSSPECIFICATIONS

3 2 1

1) Annealed coated or un-coated stranded class B copper conductor2) Ethylene propylene rubber (EPR) insulation3) Chlorosulfonated polyethylene (Hypalon) or chlorinated polyethylene(CPE) jacket

APPLICATION

Ideally suited for use in Electrical generating stations May be installed in free air all raceways or direct burial

MAXIMUM CONDUCTOR TEMPERATUREDry LocationsDry and Wet LocationsOverloadShort Circuit

90 C75 C130 C250 C

MAXIMUM OPERATING VOLTAGE600 Volts

1) Flame resistant Meets or exceeds requirements of IEEE 383 flame test2) Deformation resistant at high temperatures3) Excellent Flexibility at low temperature suitable for installation in sub-zero temperatures4) Extra tough mechanically rugged composite insulation and jacket construction6) Resistant to most oils and chemicals

ICEA S-95-658

VULCANEL EPR ANTILLAMA cable 600 volts size length National Electrical Code ReferencesAmpacities Article 31318-10Cable Trays Article 318

Dupont trade mark

reg reg

Size Number Conductor Insulation Jacket Overall Netof Diameter Thickness Thickness Diameter Weight

AWGkcmilStrands Inch mils mils inch lbMft

8 7 015 45 15 026 79

6 7 118 45 30 042 125

4 7 023 45 30 038 179

2 7 029 45 30 043 269

10 19 037 55 45 056 432

20 19 041 55 45 061 528

30 19 047 55 45 066 647

40 19 052 55 45 071 797

250 37 057 65 45 082 982

300 37 062 65 65 087 1146

352 37 067 65 65 092 1351

400 37 072 65 65 097 1480

500 37 080 65 65 105 1782

600 61 088 80 65 116 2186

750 61 098 80 65 126 2685

1000 61 114 80 65 141 3410

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

reg reg

15

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

CODE SIZE STRAND OVERALL DIAMETER NET WEIGHT RUPTURE STRENGTH

Turkey 6 61 0198 503 36 54

Swan 4 61 0250 635 58 86

Swallow 3 61 0281 714 73 108

Sparrow 2 61 0316 803 91 136

Robin 1 61 0355 902 115 171

Raven 10 61 0398 1011 145 216

Quail 20 61 0447 1135 183 273

Pigeon 30 61 0502 1275 231 344

Penguin 40 61 0563 1430 291 433

Partridge 2668 267 0642 1631 366 544

Linnet 3364 267 0721 1831 162 688

Oriole 3364 307 0741 1882 525 782

Ibis 3975 267 0783 1989 545 811

Lark 3975 307 0806 2047 619 921

Hawk 4770 267 0858 2179 654 973

Hen 4770 307 0883 2243 743 1106

Heron 5000 307 0904 2296 781 1162

Dove 5565 267 0927 2355 765 1138

Eagle 5565 307 0953 2421 869 1293

Duck 6050 547 0953 2421 779 1159

Grosbeak 6360 267 0990 2515 872 1298

Starling 7155 267 1051 2670 986 1467

Crow 7155 547 1035 2629 918 1366

Drake 7950 267 1108 2814 1095 1629

Condor 7950 547 1093 2776 1021 1520

Canary 9000 547 1162 2951 1160 1726

Rail 9540 457 1165 2959 1076 1601

Bluejay 11130 457 1259 3198 1256 1869

11903

18608

23040

28575

35550

43875

53100

66825

84308

113175

141075

173250

163125

203175

195075

238500

247500

227250

279000

234000

252000

283500

261000

315000

281250

323370

258750

309870

WORD AWG or MCM ALSteel Inch mm Lbsmft kgkm lbs

manufacturing tolerances

Condumex can currently produce a wider

BARE ACSR CABLE

ALUMINUM CONDUCTOR STEEL REINFORCED

26ACSR01

DESCRIPTION

CONDUCTORS

Aluminum 1350 wire concentrically laid overa solid or stranded galvanized steel core

Mechanical design requirements5) Good corrosion resistance

3) High resistance to mechanical strength4) Wide variety of sizes available in long

lengths to suit both electrical and

fewer towers required

strength to permit the longest possiblespans

2) Minimum sag between supports with

1) Ideal combination of conductivity and

FEATURES

Code Word quantity required in weight

ACSR cable size Aluminum Association

HOW TO ORDER

Overhead transmission subtransmission

overhead electrical cables Messenger and

overhead lines Messenger cables to support

APPLICATION

and distribution systems Static wires to protect

power support conductor in catenary systems

for railroad electrification

SPECIFICATIONS

ASTM B498 Galvanized steel class A

ASTM B232 Conductor overall

SPECIFICATIONS

ASTM B230 Aluminum wires

MAXIMUM CONDUCTOR TEMPERATURE

Normal Operation 75 degC

116

Dimension and weights shown are nominal unless otherwise indicated and subject to

range of products then what is listedPlease contact us for other items

Grand Prairie Texas800-925-9473

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
Page 18: 5Power Cable Specs Set 2 - Condumex  · PDF fileCondumex Wire and Cable 2590 114th Street, ... Type Conductors Diameter Ampacity Weight AWG ... 6 19 26.2 0.18 30 6 0.26

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

VULCANEL EPR ANTILLAMA CABLE

600 VOLTS

26ACSR01

DESCRIPTION

FEATURES

HOW TO ORDER

SPECIFICATIONSSPECIFICATIONS

3 2 1

1) Annealed coated or un-coated stranded class B copper conductor2) Ethylene propylene rubber (EPR) insulation3) Chlorosulfonated polyethylene (Hypalon) or chlorinated polyethylene(CPE) jacket

APPLICATION

Ideally suited for use in Electrical generating stations May be installed in free air all raceways or direct burial

MAXIMUM CONDUCTOR TEMPERATUREDry LocationsDry and Wet LocationsOverloadShort Circuit

90 C75 C130 C250 C

MAXIMUM OPERATING VOLTAGE600 Volts

1) Flame resistant Meets or exceeds requirements of IEEE 383 flame test2) Deformation resistant at high temperatures3) Excellent Flexibility at low temperature suitable for installation in sub-zero temperatures4) Extra tough mechanically rugged composite insulation and jacket construction6) Resistant to most oils and chemicals

ICEA S-95-658

VULCANEL EPR ANTILLAMA cable 600 volts size length National Electrical Code ReferencesAmpacities Article 31318-10Cable Trays Article 318

Dupont trade mark

reg reg

Size Number Conductor Insulation Jacket Overall Netof Diameter Thickness Thickness Diameter Weight

AWGkcmilStrands Inch mils mils inch lbMft

8 7 015 45 15 026 79

6 7 118 45 30 042 125

4 7 023 45 30 038 179

2 7 029 45 30 043 269

10 19 037 55 45 056 432

20 19 041 55 45 061 528

30 19 047 55 45 066 647

40 19 052 55 45 071 797

250 37 057 65 45 082 982

300 37 062 65 65 087 1146

352 37 067 65 65 092 1351

400 37 072 65 65 097 1480

500 37 080 65 65 105 1782

600 61 088 80 65 116 2186

750 61 098 80 65 126 2685

1000 61 114 80 65 141 3410

Dimension and weights shown are nominal unless otherwise indicated and subject tomanufacturing tolerances

reg reg

15

RoHS

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

CODE SIZE STRAND OVERALL DIAMETER NET WEIGHT RUPTURE STRENGTH

Turkey 6 61 0198 503 36 54

Swan 4 61 0250 635 58 86

Swallow 3 61 0281 714 73 108

Sparrow 2 61 0316 803 91 136

Robin 1 61 0355 902 115 171

Raven 10 61 0398 1011 145 216

Quail 20 61 0447 1135 183 273

Pigeon 30 61 0502 1275 231 344

Penguin 40 61 0563 1430 291 433

Partridge 2668 267 0642 1631 366 544

Linnet 3364 267 0721 1831 162 688

Oriole 3364 307 0741 1882 525 782

Ibis 3975 267 0783 1989 545 811

Lark 3975 307 0806 2047 619 921

Hawk 4770 267 0858 2179 654 973

Hen 4770 307 0883 2243 743 1106

Heron 5000 307 0904 2296 781 1162

Dove 5565 267 0927 2355 765 1138

Eagle 5565 307 0953 2421 869 1293

Duck 6050 547 0953 2421 779 1159

Grosbeak 6360 267 0990 2515 872 1298

Starling 7155 267 1051 2670 986 1467

Crow 7155 547 1035 2629 918 1366

Drake 7950 267 1108 2814 1095 1629

Condor 7950 547 1093 2776 1021 1520

Canary 9000 547 1162 2951 1160 1726

Rail 9540 457 1165 2959 1076 1601

Bluejay 11130 457 1259 3198 1256 1869

11903

18608

23040

28575

35550

43875

53100

66825

84308

113175

141075

173250

163125

203175

195075

238500

247500

227250

279000

234000

252000

283500

261000

315000

281250

323370

258750

309870

WORD AWG or MCM ALSteel Inch mm Lbsmft kgkm lbs

manufacturing tolerances

Condumex can currently produce a wider

BARE ACSR CABLE

ALUMINUM CONDUCTOR STEEL REINFORCED

26ACSR01

DESCRIPTION

CONDUCTORS

Aluminum 1350 wire concentrically laid overa solid or stranded galvanized steel core

Mechanical design requirements5) Good corrosion resistance

3) High resistance to mechanical strength4) Wide variety of sizes available in long

lengths to suit both electrical and

fewer towers required

strength to permit the longest possiblespans

2) Minimum sag between supports with

1) Ideal combination of conductivity and

FEATURES

Code Word quantity required in weight

ACSR cable size Aluminum Association

HOW TO ORDER

Overhead transmission subtransmission

overhead electrical cables Messenger and

overhead lines Messenger cables to support

APPLICATION

and distribution systems Static wires to protect

power support conductor in catenary systems

for railroad electrification

SPECIFICATIONS

ASTM B498 Galvanized steel class A

ASTM B232 Conductor overall

SPECIFICATIONS

ASTM B230 Aluminum wires

MAXIMUM CONDUCTOR TEMPERATURE

Normal Operation 75 degC

116

Dimension and weights shown are nominal unless otherwise indicated and subject to

range of products then what is listedPlease contact us for other items

Grand Prairie Texas800-925-9473

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
Page 19: 5Power Cable Specs Set 2 - Condumex  · PDF fileCondumex Wire and Cable 2590 114th Street, ... Type Conductors Diameter Ampacity Weight AWG ... 6 19 26.2 0.18 30 6 0.26

Condumex Wire and Cable 2590 114th Street 200 - Grand Prairie TX 75050 (800) 925-947307-04

CODE SIZE STRAND OVERALL DIAMETER NET WEIGHT RUPTURE STRENGTH

Turkey 6 61 0198 503 36 54

Swan 4 61 0250 635 58 86

Swallow 3 61 0281 714 73 108

Sparrow 2 61 0316 803 91 136

Robin 1 61 0355 902 115 171

Raven 10 61 0398 1011 145 216

Quail 20 61 0447 1135 183 273

Pigeon 30 61 0502 1275 231 344

Penguin 40 61 0563 1430 291 433

Partridge 2668 267 0642 1631 366 544

Linnet 3364 267 0721 1831 162 688

Oriole 3364 307 0741 1882 525 782

Ibis 3975 267 0783 1989 545 811

Lark 3975 307 0806 2047 619 921

Hawk 4770 267 0858 2179 654 973

Hen 4770 307 0883 2243 743 1106

Heron 5000 307 0904 2296 781 1162

Dove 5565 267 0927 2355 765 1138

Eagle 5565 307 0953 2421 869 1293

Duck 6050 547 0953 2421 779 1159

Grosbeak 6360 267 0990 2515 872 1298

Starling 7155 267 1051 2670 986 1467

Crow 7155 547 1035 2629 918 1366

Drake 7950 267 1108 2814 1095 1629

Condor 7950 547 1093 2776 1021 1520

Canary 9000 547 1162 2951 1160 1726

Rail 9540 457 1165 2959 1076 1601

Bluejay 11130 457 1259 3198 1256 1869

11903

18608

23040

28575

35550

43875

53100

66825

84308

113175

141075

173250

163125

203175

195075

238500

247500

227250

279000

234000

252000

283500

261000

315000

281250

323370

258750

309870

WORD AWG or MCM ALSteel Inch mm Lbsmft kgkm lbs

manufacturing tolerances

Condumex can currently produce a wider

BARE ACSR CABLE

ALUMINUM CONDUCTOR STEEL REINFORCED

26ACSR01

DESCRIPTION

CONDUCTORS

Aluminum 1350 wire concentrically laid overa solid or stranded galvanized steel core

Mechanical design requirements5) Good corrosion resistance

3) High resistance to mechanical strength4) Wide variety of sizes available in long

lengths to suit both electrical and

fewer towers required

strength to permit the longest possiblespans

2) Minimum sag between supports with

1) Ideal combination of conductivity and

FEATURES

Code Word quantity required in weight

ACSR cable size Aluminum Association

HOW TO ORDER

Overhead transmission subtransmission

overhead electrical cables Messenger and

overhead lines Messenger cables to support

APPLICATION

and distribution systems Static wires to protect

power support conductor in catenary systems

for railroad electrification

SPECIFICATIONS

ASTM B498 Galvanized steel class A

ASTM B232 Conductor overall

SPECIFICATIONS

ASTM B230 Aluminum wires

MAXIMUM CONDUCTOR TEMPERATURE

Normal Operation 75 degC

116

Dimension and weights shown are nominal unless otherwise indicated and subject to

range of products then what is listedPlease contact us for other items

Grand Prairie Texas800-925-9473

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20
Page 20: 5Power Cable Specs Set 2 - Condumex  · PDF fileCondumex Wire and Cable 2590 114th Street, ... Type Conductors Diameter Ampacity Weight AWG ... 6 19 26.2 0.18 30 6 0.26

Grand Prairie Texas800-925-9473

  • Page 1
  • Page 2
  • Page 3
  • Page 4
  • Page 5
  • Page 6
  • Page 7
  • Page 8
  • Page 9
  • Page 10
  • Page 11
  • Page 12
  • Page 13
  • Page 14
  • Page 15
  • Page 16
  • Page 17
  • Page 18
  • Page 19
  • Page 20