6 414 345 811 xx hand - delta light...- delta light recommands to use the power supplies that are...
TRANSCRIPT
1Last Update ALLU 18/11/2015
NORTH AMERICAN EDITION
HEADQUARTERS - www.deltalight.com - USA - www.deltalight.us - CANADA - www.deltalight.ca
Installation instruction SPY FOCUS CLIP
Application Ceiling recessed mounted
Finishing section to be used with DELTA LIGHT rough-in housing, plasterframeFor indoor use only
Color FinishW - White
B - Black
Light sourceOne 10,4W max POWERLED WHITE (500mA) ( Typical forward voltage: 20,7V )
1x ADJUSTABLE REFLECTOR 11°- 44° INCLUDED
Power SupplyRemote current controled class 2 power supply required. (not supplied)
Max 500mA, typical forward voltage 11,9V.
Do not interconnect in parallel!
Specification featuresPowder coated aluminum assembly
Pre-installed springs for easy installation
Suitable for damp locations
DimensionsHeight: 111mm = 4”-3/8
Width: ø62mm = 2”-7/16
Ceiling Cut out: 50,8mm = 2”
Required options for non-class 2 power limited circuitsHousing for IC and/or airtight applications
Plasterframe for IC applications
2 = 3000K
3 = 2700K
Color temperature
7 - IC AT Housing S6 202 00 - Plate D50 0 1 - Bar hangers standard
1 - Bar hangers standard0 - No bar hangers
1 - 120V2 - 277V3 - 120-277V
Range Installation type
Lamp Source Opening
Voltage Mounting Option
1 - Bar hangers standard0 - No bar hangers
1 - 120V2 - 277V3 - 120-277V
Range Installation type
Voltage Mounting Option
6 202 Plate D50 1 - Bar hangers standard06 - IC Plasterframe S6 00 - 0
Lamp Source Opening
NICICATSPY FOCUS CLIP 927
6 414 345 811 92 = W-W / B-B / W-BSPY FOCUS CLIP 9306 414 345 811 93 = W-W / B-B / W-BSPY FOCUS CLIP 9356 414 345 811 95 = W-W / B-B / W-B
35mm
1”-3/8
2mm
1/16"
Conforms to ANSI/UL Std. 2108
Cert. to CAN/CSA Std. 22.2 No. 250.0
Ø58mm
Ø2”-5/16
0-90°355°
108mm
4”-1/4Ø62mm
Ø2”7/16
Installation instruction
2
NORTH AMERICAN EDITION
HEADQUARTERS - www.deltalight.com - USA - www.deltalight.us - CANADA - www.deltalight.ca
A
B
A
B
SAVE!
B
A
INSTALLATION LUMINAIRE
SPY FOCUS CLIP
if not installed in a class 2 power limited circuit
NICICAT
HOUSING PLASTERFRAME
Not Supplied Rough-in Housing or Plasterframe
Required
Accessories
2X
NIC
MOUNTING KIT
1
4
5
2
6
CAUTION!
CLASS 2 POWER LIMITED CIRCUITS ONLY
ATTENTION!
SEULEMENT POUR RESEAUS CLASS 2,
A PUISSANCE LIMITE
MAX 500mA DC (red/rouge: +, black/noir: -)
1/2”1 3 4
2
MAX 2 x 14-18AWG 50L/STR
REDROUGE
REDROUGE
BLACKNOIR
BLACKNOIR
+ +
--
3
NORTH AMERICAN EDITION
HEADQUARTERS - www.deltalight.com - USA - www.deltalight.us - CANADA - www.deltalight.ca
Installation instruction
INSTALLATION LUMINAIRE
SPY FOCUS CLIP
on
off
10
355°
90
- Use only power supplies that are certified according to the applicable IEC or UL safety standards.
- Use only SELV power supplies.
- Check the ratings of the power supply with those of the luminaire.
The maximum current rating must be taken into account.
The indicated typical voltage must not be used to select a constant voltage power supply but is indented to used
to select a constant current power supply that is able to cover that typical voltage.
- Take appropriate ESD measures. Avoid touching bare conductors.
- Leds or led luminaires that require a current controlled power supply must never be connected in parallel.
- Leds can be damaged by the contact with certain chemicals or chemical gasses.
Therefore led domes or led engines should never be cleaned with chemical substances.
The following substances have proven to have a negative influence on the performance and
must not be used in the direct environment of a led luminaire.
Methyl acetate or ethyl acetate (i.e., nail polish remover)
Cyanoacrylates (i.e., “Superglue”)
Glycol ethers (including Radio Shack® Precision Electronics Cleaner - dipropylene glycol monomethyl ether)
Formaldehyde or butadiene (including Ashland PLIOBOND® adhesive)
Dymax 984-LVUF conformal coating
Loctite Sumo Glue
Gorilla Glue
Bleach, Bleach-containing cleaners, sprays
Loctite 384 adhesive
Loctite 7387 activator
Loctite 242 threadlocker
- Remove insulation and/or provide sufficient ventilation so that the indicated max Tc is not surpassed.
- Leds are susceptible to switching transients. Therefore switching must be done in the primary circuit
of the power supply.
- DELTA LIGHT recommands to use the power supplies that are indicated in the Lighting Bible.
- Respect polarity
- Don’t test LED luminaires one by one on a powersupply that is switched on.
DO NOT TOUCH OR CLEAN THE LED ARRAY!
!
NO SECONDARY SWITCHING
AC DC
AC DC
ATTENTION
OBSERVE PRECAUTIONS FOR
HANDLING ELECTROSTATIC
DISCHARGE SENSITIVE
DEVICES
7 8
Min 11°
Max 44°
Min 11°
Max 44°