6-pvtsim-4-olga-upd

26
PVTsim for OLGA

Upload: osecul

Post on 08-Oct-2014

1.079 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: 6-PVTsim-4-OLGA-upd

PVTsim for OLGA

Page 2: 6-PVTsim-4-OLGA-upd

PVTsim by Calsep

• Calsep – a Danish alliance partner– Founded in 1982– Specialists in PVT and fluid properties

calculations– Ensures most updated PVT calculation

methods for OLGA users

• PVTsim– On the market since 1991– Developed for process, reservoir and

laboratory engineers– More than 200 installations worldwide

Page 3: 6-PVTsim-4-OLGA-upd

PVTsim 15 main window

Page 4: 6-PVTsim-4-OLGA-upd

PVTsim OLGA Version

• Limited version of full PVTsim package– additional modules available through Calsep

• Use PVTsim to– characterize fluids

• tune characterized fluid to saturation points• mix fluids by volume, by weight or on molar basis• do flash calculations• calculate phase envelopes• calculate various fluid properties• make OLGA fluid property tables (.tab files)

Page 5: 6-PVTsim-4-OLGA-upd

Basic Models in PVTsim

• Equation of state (EOS)– Soave-Redlich-Kwong - Peneloux (SRK-P)

• default EOS– Peng-Robinson - Peneloux (PR-P)– Soave-Redlich-Kwong (SRK)– Peng-Robinson (PR)

• Water mixed with hydrate inhibitors– EOS with Huron and Vidal (1979) mixing rule

Page 6: 6-PVTsim-4-OLGA-upd

C7+ Characterization Procedure

• Pedersen et al, 1984 - estimate distributions of– mol fraction, density and molecular weight

• Based on above estimates– Calculate properties of carbon number fractions

• Tc , Pc ,acentric factor needed by EOS

– Group the carbon number fractions• TBP-fractions + estimated carbon number fractions of

plus fraction into a user defined number of pseudo components (default 12)

Page 7: 6-PVTsim-4-OLGA-upd

Estimate Molar Distribution

Page 8: 6-PVTsim-4-OLGA-upd

Estimate Density Distribution

Page 9: 6-PVTsim-4-OLGA-upd

Estimate Molecular Weight

• Molecular weight versus carbon number fraction

MWN = 14 CN - 4

– MWN : Molecular weight– CN : Carbon number fraction

Page 10: 6-PVTsim-4-OLGA-upd

Transport Properties• Viscosity

– Corresponding states principle (CSP) - default method• Pedersen et al, 1987

– Lohrenz-Bray-Clark (LBC)• same 1964

• Thermal Conductivity– Pedersen et al, 1987

Page 11: 6-PVTsim-4-OLGA-upd

Transport Properties cont.

• Surface Tension– Gas/oil: Weinaug & Katz 1943– Gas/pure water: API Technical databook, 1983– Oil/pure water: API Technical databook, 1983– Gas/salt water & oil/salt water: Firoozabadi & Ramey, 1988

Page 12: 6-PVTsim-4-OLGA-upd

OLGA Tables Content

• General specification– Pressure, temperature, total water mass fraction, gas mass fraction,

water vapor fraction of gas, • Physical properties for each phase

– density– density derivatives– enthalpy– heat capacity– entropy– viscosity– thermal conductivity– surface tension

Page 13: 6-PVTsim-4-OLGA-upd

OLGA Tables - Water Flashing

• Complete three-phase flash is always performed when water and other aqeous components(MeOH, MEG etc.) are present, i.e. full miscibility.

• For two-phase tables two liquid phases are lumped into one liquid with average fluid properties.

Page 14: 6-PVTsim-4-OLGA-upd

OLGA Tables - Water Flashing cont.

– Water properties from EOS

– Density and viscosity corrected for salts

Page 15: 6-PVTsim-4-OLGA-upd

References

• Search in pvtdoc.doc in the PVTsim directory• Characterization

– Pedersen: Ind. Chem. Process Des. Dev., 1984, 163 - 170• Mixing rule

– Huron, M. J. and Vidal, J.: Fluid Phase Eq. 3, 1979, 255.• Transport properties

– Weinaug, C. F. and Katz, D. L., Ind. Eng. Chem. 35, 1943, 239.– Lohrenz, J.,, Bray, B. G. and Clark, C. R.

J. Pet. Technol., Oct. 1964, 1171-1176.– Pedersen et al: Chem. Eng. Sci. 42, 1987, 182-186– Pedersen et al: J. Can. Pet. Tech, 1988– Firoozabadi, A. and Ramey, H. J., Journal of Canadian Petroleum

Technology 27, 1988, pp. 41-48.

Page 16: 6-PVTsim-4-OLGA-upd

PVTsim - Composition Input

Page 17: 6-PVTsim-4-OLGA-upd

PVTsim - Characterized Fluid

Page 18: 6-PVTsim-4-OLGA-upd

PVTsim - Mixing Fluids

Page 19: 6-PVTsim-4-OLGA-upd

PVTsim - Recombining Fluids

Page 20: 6-PVTsim-4-OLGA-upd

PVTsim - Phase Envelope

0

1000

2000

3000

4000

5000

6000

-100 0 100 200 300 400 500 600 700 800 900

Temperature/°F

Crit P

TEST 4 BHS OIL C10+

Page 21: 6-PVTsim-4-OLGA-upd

PVTsim - OLGA fluid table file input

Specify a sufficiently wide region of P and T.Account for occasional peak (high and low) values.

e.g.Tmin could be ≤ -10 CPmin should be ≥ 0.5 Bara

Page 22: 6-PVTsim-4-OLGA-upd

Example

Page 23: 6-PVTsim-4-OLGA-upd

Extract of fluid table

Page 24: 6-PVTsim-4-OLGA-upd

Fluid tables - Check the Results!

• Check the fluid tables for discontinuities and strange tendencies as function of P and T e.g.– Gas mass fraction– Densities– Derivatives of hydrocarbon liquid density

• Check the single phase regions in particular (gas mass fraction equals 0 or 1)

• Use the plotting facility in the OLGA 5 GUI

Page 25: 6-PVTsim-4-OLGA-upd

OLGA 5 fluid plotting (open a .tab file)

Page 26: 6-PVTsim-4-OLGA-upd

Densities as function of P at 200 Bara