60/100 concentric flue system parts - mkm building … · 60/100 concentric flue system parts...
TRANSCRIPT
2
60/100 Concentric Flue System Parts
MG82330 Vertical Terminal 60/100 (Avanta Plus) 1. Vertical terminal 2. Boiler connector 3. Wall bracket
MG83815 Vertical Terminal 60/100 (Avanta 12/18/24v) 1. Vertical terminal 2. Wall bracket
MG82329 Std Concentric Flue 60/100 (Avanta 12/18/24v) 1. Boiler bend (Avanta 12/18/24v) 2. Telescopic terminal 3. Wall plates - (2 x white)
MG82328(MG82335 1m extended option)Std Concentric Flue 60/100 (Avanta Plus) 1. Low profile bend (Avanta Plus) 2. Telescopic terminal 3. Wall plates - (2 x white)
1
2 3
1
2
3
1
3 2
1
2
3
MG87910 Roof flashing (20° to 45° pitched)
MG87372 Roof flashing (flat)
MG83236 - 250mm MG83237 - 500mm MG83238 - 1000mm Flue Extension Piece (cannot be cut) c/w Clamp
MG83241 - 500mm MG83242 - 1000mm Flue Extension Piece (cuttable) c/w Clamp
MG83240 - 275 to 315mm Flue extension piece (adjustable) c/w Clamp
MG83247 90° Bend c/w Clamp (single seal)
MG83248 45° Bend c/w Clamp (single seal)
4
60/100mm Concentric Flue Spare Parts(not all illustrated)
Part No Description 116534 LP adaptor plate (Avanta Plus) MG27218 Air inlet seal for LP boiler bend (flue side) MG87650 Clamp MG87720 Wall bracket 100mm MG27245 Air inlet seal for Avanta 18v boiler bend MG85010 Wall plate - Black MG75682 Wall Plate - White
Wall Plate See table for part Nos.
MG83243
S62768 Boiler connector (Avanta Plus) - for vertical outlet supplied as standard with Part No. MG82330 Vertical flue kit (Avanta Plus) -
MG82333 LP Bend + adaptor plate (Avanta Plus)
116534 LP adaptor plate (Avanta Plus) -supplied as standard with boiler-
5
Avanta Plus 60/100mm Concentric Flue System
MG82330 - Vertical Flue (Avanta Plus) Installed in Flat Roof
99 o/d
805 ±10 to inside weathercollar
615 ±10 to rooflevel
10120 o/d Min Hole in roof
To suit site
MG82330 - Vertical Flue (Avanta Plus) Installed in Pitched Roof
45
5
Weather collar detail
805±10To inside of weather collar
760±10
Pitch20° to 45°
1099 o/d
120 o/d Min Hole in Roof
To suit site
MG82328 Std Concentric Flue 60/100 ( Avanta Plus) installed 1. Low profile bend (Avanta Plus) 2. Telescopic terminal 3. Wall plates (2 white)
Wall Depth Max 450mm - Min 250mm
Terminal is telescopic132.5
Core Drill Wall - 125mm Dia.C/L of Terminal
98
Top of boiler
100
NOTE: If the wall depth is less than 250mm the telescopic terminal can still be used by removing the boiler end part and cutting the remaining outer part down to suit wall depth (min 150mm) + 60mm out of wall to connect to bend) Remember to leave the inner pipe 10mm longer than the outer
6
Avanta 12/18/24ov 60/100mm Concentric Flue System
MG83815 - Vertical Flue (Avanta 12/18/24ov) Installed on Flat Roof
99 o/d
805 ±10 to inside weathercollar
615 ±10 to rooflevel
10
120 o/d Min Hole in roof
45
5
Weather collar detail
MG83815 - Vertical Flue (Avanta 12/18/24ov) Installed in Pitched Roof
805±10To inside of weather collar
760±10
Pitch20° to 45°
1099 o/d
120 o/d Min Hole in Roof
Wall Depth Max 450mm - Min 250mm
Terminal is telescopic132.5
Core Drill Wall - 125mm Dia.
Top of boiler
164
C/L of Terminal
NOTE: If the wall depth is less than 250mm the telescopic terminal can still be used by removing the boiler end part and cutting the remaining outer part down to suit wall depth (min 150mm) + 60mm out of wall to connect to bend) Remember to leave the inner pipe 10mm longer than the outer
MG82329 Std Concentric Flue 60/100 ( Avanta ov) installed 1. Boiler bend (Avanta ov) 2. Telescopic terminal 3. Wall plates (2 white)
7
Avanta Plus 60/100mm Plume Management Kits
MG82331 PMK-Horizontal Terminal Kit (Avanta Plus) 1. PMK Wall terminal 2. LP boiler bend (Avanta Plus) 3. Wall plates (1 white and 1 black) 4. 1000mm flue extension (60mm) 5. Support bracket (60mm) 6. 90 bend (60mm) 7. Flue outlet (60mm) 8. Bird guard NOTE: The horizontal terminal unit must be in-stalled with the outlet pointing vertically up-wards
PMK– Horizontal Terminal Kit installed
Wall Depth - Max 550mm - Min 150mm
Terminal inner and outer can be cut to suit- Note: Maintain the 10mm difference
Core Drill Wall - 125mm Dia.
Max
110
0mm
- M
in 1
50m
m
Not
e: C
an b
e ex
tend
ed w
ith e
xtra
par
ts
C/L of Terminal
98
Top of boiler
100
132.5
1
2
3
4 5
6 7 8
8
Avanta Plus 60/100mm Plume Management Kits
PMK– Horizontal Terminal Kit with a vertical outlet installed
Wall Depth - Max 550mm - Min 150mm
Terminal inner and outer can be cut to suit- Note: Maintain the 10mm difference
Core Drill Wall - 125mm Dia.
Sta
ndar
d Te
rmin
al
Max
100
0mm
- M
in 1
50m
m
Not
e: C
an b
e ex
tend
ed w
ith e
xtra
par
ts
Roof level
132.5
C/L of Terminal
98
Top of boiler
100
MG82331 + MG83235 PMK-Horizontal Terminal Kit (Avanta Plus) 1. PMK Wall terminal 2. LP boiler bend (Avanta Plus) 3. Wall plates (1 white and 1 black) 4. 1000mm flue extension (60) 5. Support bracket (60) 6. Vertical outlet NOTE: The horizontal terminal unit must be in-stalled with the outlet pointing vertically up-wards The vertical outlet replaces the 90 bend, flue outlet and bird guard which are dis-carded.
1
2
3
4
5
6
9
Avanta 12/18/24ov 60/100mm Plume Management Kits
PMK Horizontal Terminal Kit (Avanta 12/18/24ov) installed
Wall Depth - Max 550mm - Min 150mm
Terminal inner and outer can be cut to suit- Note: Maintain the 10mm difference100
132.5
Top of boilerflue outlet
164
C/L of TerminalCore Drill Wall - 125mm Dia.
Max
110
0mm
- M
in 1
50m
m
Not
e: C
an b
e ex
tend
ed w
ith e
xtra
par
ts
MG83230 PMK-Horizontal Terminal Kit (Avanta ov) 1. PMK Wall terminal 2. Boiler bend (Avanta ov) 3. Wall plates (1 white and 1 black) 4. 1000mm flue extension (60mm) 5. Support bracket (60mm) 6. 90 bend (60mm) 7. Flue outlet (60mm) 8. Bird guard NOTE: The horizontal terminal unit must be in-stalled with the outlet pointing vertically up-wards
1
2
3
4
5
6 7 8
10
Avanta 12/18/24ov 60/100mm Plume Management Kits
PMK Horizontal Terminal (Avanta 12/18/24ov) with a vertical outlet installed
Wall Depth - Max 550mm - Min 150mm
Terminal inner and outer can be cut to suit- Note: Maintain the 10mm difference100
132.5
Top of boilerflue outlet
164
C/L of TerminalCore Drill Wall - 125mm Dia.
Roof level
MG83230 + MG83235 PMK-Horizontal Terminal Kit (Avanta OV) 1. PMK Wall terminal 2. LP boiler bend (Avanta OV) 3. Wall plates (1 white and 1 black) 4. 1000mm flue extension (60mm) 5. Support bracket (60mm) 6. Vertical outlet NOTE: The horizontal terminal unit must be in-stalled with the outlet pointing vertically up-wards The vertical outlet replaces the 90 bend, flue outlet and bird guard which is dis-carded.
1
2
3
4
5
6
Sta
ndar
d T
erm
inal
M
ax 1
000m
m -
Min
150
mm
N
ote:
Can
be
exte
nded
with
ext
ra p
arts
11
Avanta Plus 60/100mm PMK Balcony Terminal Kit
MG82332 PMK Balcony Flue 60/100mm(Avanta Plus) 1. PMK Balcony terminal 2. LP Boiler bend (Avanta Plus) 3. Wall plates (1 white and 1 black) 4. Two 1000mm flue extensions (60mm) 5. Two Support brackets(60mm) 6. Flue outlet (60mm) 7. Bird guard NOTE: Horizontal Terminal unit must be installed with the flue exit point at the top of the air inlet. (flue exit is offset from centre line)
PMK Balcony Flue 60/100 (Avanta Plus) installed for a 2M overhang
Wall Depth - Max 550mm - Min 150mm Terminal can be cut to suit
Core Drill Wall - 125mm Dia. Balcony
Standard Balcony Kit for up to 2M One additional length allowed up to a Max of 3M
Note: the extension kit must be graded back to the Terminal at approx 3° to allow condensate to drain to boiler
C/L of Terminal
98
Top of boiler
100
132.5
1
2
3 4 5 6
7
Wall Depth - Max 550mm -Min 150mm Terminal can be cut to suit
12
Avanta 12/18/24ov 60/100mm PMK Balcony Terminal Kit
MG82322 PMK Balcony Flue 60/100mm (Avanta ov) 1. PMK Balcony terminal 2. Boiler bend (Avanta ov) 3. Wall plates (1 white and 1 black) 4. Two 1000mm flue extensions (60mm) 5. Two Support brackets(60mm) 6. Flue outlet (60mm) 7. Bird guard NOTE: Horizontal Terminal unit must be installed with the flue exit point at the top of the air inlet. (flue exit is offset from centre line)
PMK– Balcony Flue 60/100mm (Avanta ov) installed for a 2M overhang
164
Top of boiler
C/L of Terminal
100
132.5
Note: the extension kit must be graded back to the Terminal at approx 3° to allow condensate to drain to boiler
Standard Balcony Kit for up to 2M overhang One additional length allowed up to a Max of 3M
Balcony
Wall Depth - Max 700mm - Min 150mm Terminal can be cut to suit
Core Drill Wall - 125mm Dia.
1
2
3 4 5
6
7
13
MG82323 PMK-Horizontal outlet (60)
MG83235 PMK-Vertical outlet terminal (60)
MG83234 PMK– 1000mm Flue Exten-sion piece c/w wall bracket (60)
MG83231 PMK-45°Angle deflector (60) for use with Std Wall Terminal Kits (MG82328 and MG82329) only
MG83232 PMK-90° Bend (60)
MG83233 PMK-45° Bend (60)
60/100 Plume Management Spare Parts
MG82325 PMK-Wall bracket (60) not illustrated
60/100 Plume Management Spare Parts
MG82320 PMK-Horizontal Terminal only
MG83249 PMK-90° Bend + horizontal outlet c/w bird guard (60)
MG82321 PMK-Balcony Terminal only