Read these instructions carefully. These instructions MUST stay with this product.
USASERVICE OFFICEDometic Corporation1120 North Main StreetElkhart, IN 46514
CANADADometic Corporation46 Zatonski, Unit 3Brantford, ON N3T 5L8CANADA
SERVICE CENTER &DEALER LOCATIONSPlease Visit:www.eDometic.com
FOR YOUR SAFETYDo not store or use gasoline or other flammable vapors and liquids in the vicin-ity of this or any other appliance.
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
REFRIGERATORRM2351 RM2510 DM2662 DM2862 NDA1402RM2354 RM2551 DM2663 RM3962RM2410 RM2554 RM3762 NDM1062RM2451 RM2620 RM2820 RM1350RM2454 DM2652 DM2852 RM1350SL
If the refrigerator stops cooling - or - if it emits an ammonia smell, immediately turn the refrigerator off and contact a Service Center.
REVISION EForm No. 3313238.036 6/17(French 3313239.034_E)©2017 Dometic CorporationLaGrange, IN 46761
INST
ALL
ATIO
NIN
STR
UC
TIO
NS
RECORD THIS INFORMATION FOR FUTURE REFERENCE:
Model NumberSerial NumberDate PurchasedRetailer / Qualified Installer
If you smell gas:1. Open windows.2. Do not attempt to light appliance.3. Do not touch electrical switches.
4. Extinguish any open flame.5. Shut off fuel supply.6. Evacuate immediately and call emergency services.
Failure to follow these instructions could result in fire or explosion, which could cause property damage, personal injury, or death.
FIRE OR EXPLOSION HAZARD
- 2 -
CERTIFICATION AND CODE REQUIREMENTS ............................................................................. 3
REFRIGERATOR REMOVAL / DISPOSAL ....................................................................................... 4
INSTALLATION PREPARATION ....................................................................................................... 5
VENT APPLICATION TYPES ........................................................................................................... 8
INSTALLATION PROCEDURE ....................................................................................................... 13
APPENDIX A - OVERALL & ROUGH IN DIMENSIONS FOR ENCLOSURE ................................. 28
APPENDIX B - MINIMUM VENTILATION HEIGHTS ...................................................................... 29
APPENDIX C - APPROVED VENTS ............................................................................................... 30
APPENDIX D - VENT INSTALLATION PROCEDURES.................................................................. 34
APPENDIX E - REARVIEW EQUIPMENT ...................................................................................... 36
APPENDIX F - WIRING DIAGRAMS .............................................................................................. 43
CONTENTS
SYMBOLSThe following symbols are used throughout this manual:
This is the safety alert symbol. It is used to alert you to personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION, used with the safety alert symbol, indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE is used to address practices not related to personal injury.
Information
Step-by-step instructions
- 3 -
This appliance is certified under the latest edition of ANSI Z21.19•CSA 1.4 Refrigerators using gas fuel. The installation must conform with local codes, or in absence of local codes, the following standards as applicable.
U.S.A. ● ANSI/NFPA70, National Electrical Code (NEC)
● ANSI/NFPA 1192, Recreational Vehicles Code
● Title 24 CFR, Part 3280, Manufactured Home Construction and Safety Standard
● National Fuel Gas Code, ANSI Z223.1/NFPA 54
CANADA ● CSA C22.1, Parts l & ll, Canadian Electrical Code
● CSA Z240 RV Series, Recreational Vehicles
● CSA Z240.4, Gas-Equipped Recreational Vehicles and Mobile Housing
● CSA B149.1, Natural Gas and Propane Installation Code
CERTIFICATION AND CODE REQUIREMENTS
The installation should be performed by qualified personnel only and must conform to all relevant local authori-ties. Be aware of possible safety hazards when seeing alert symbols on the refrigerator as well as in this manual. To ensure safe and efficient operation, the refrigerator and vents must be installed as identified in this manual without modification. The installer must affix the refrigerator model’s user manual to the refrigerator.
Appearance of your product may vary from illustrations shown in this document.
Not all procedures in this document will apply to your product. Read and follow the information pertaining to the specific model number of your product before starting the installation.
INTRODUCTION
Any modifications or deviations:• Can lead to carbon monoxide leaking into the
living area.• Can reduce cooling performance and/or result in
damage to the refrigerator. • Will void agency certifications.• Will void refrigerator warranty.
Any deviation from the prescribed installation instructions in this manual must have prior written approval and safety certification verification from Dometic Corporation.
- 4 -
1. Leave shelves in place to prevent children from eas-ily climbing inside refrigerator.
2. Recycle refrigerator using environmentally respon-sible practices.
Refrigerants MUST be recovered/recycled by a licensed technician who is EPA certi-fied in refrigerant recovery and recycling procedures. Disposal MUST comply with all applicable local and national codes.
INSPECT REFRIGERATOR ENCLOSURE• Verify there are no holes (other than ventilation holes)
inside enclosure.• Verify surface for sealing strips (isolating appliance
combustion system from vehicle interior) is clean and flat to allow a complete seal.
• Verify no objects are protruding into enclosure that could contact refrigerator.
Exceptions include utility connections for refrigerator.
• Verify seams are sealed to prevent flue gases from leaking into living area.
• Verify utility hookups (Water, LP gas, Electrical) for refrigerator are present and comply with all applicable codes.
• Review enclosure and venting requirements beginning with section, "Installation Preparation" on page (6).
• When enclosure is verified to meet all requirements, install refrigerator. See section, "Installation Proce-dure" on page (14)
REMOVE OLD REFRIGERATOR1. Remove screws anchoring the refrigerator to the
enclosure.2. Slide refrigerator out of its enclosure (refrigerator
compartment) and remove from RV.
REFRIGERATOR REMOVAL / DISPOSALSkip this section for OEM (new RV) installation or for RV's without existing refrigerator.
PREPARE TO REMOVE OLD REFRIGERA-TOR
1. Unplug 120 Vac power cord from receptacle at rear of refrigerator enclosure.
2. Disconnect 12 Vdc leads from refrigerator and cap lead ends.
Always use a backup wrench when loosing and tightening LP gas connections.
3. Turn LP gas supply (to refrigerator) off.
SUFFOCATION AND ENTRAPMENT HAZARD: Remove fresh food and freezer doors from refriger-ator prior to disposal. Failure to obey this warning could entrap a child and result in death or brain damage.
REFRIGERATOR DISPOSAL
FIRE OR EXPLOSION HAZARD: Turn OFF LP gas supply at tank. Failure to obey this warning could result in death or serious injury.
4. Disconnect LP gas line from refrigerator and cap line.
FIRE OR EXPLOSION HAZARD: NEVER use an open flame to check for gas leaks. Failure to obey this warning could result in death or serious injury.
5. Verify there are no LP gas leaks.
- 5 -
INSTALLATION PREPARATIONASSEMBLING THE REFRIGERATOR ENCLOSURE
The ventilation compartment is part of the product safety certification and must not be used for any other purpose than securing air for combustion and ventila-tion of flue gases and warm air.
Ventilation Compartment
Enclosure
Ref
riger
ator
CLEARANCES (FIG 2)Top (G) 0” Min to 1/4” MaxSide (K) 0” Min to 1/4” MaxBottom (L) 0” Min to 0” MaxRear (M1) 0” Min to 1” Max
1 The distance between the refrigerator cooling unit and the wall or baffle behind it.
Read and follow these points:• The refrigerator must be level and installed in a substantial
enclosure, see “APPENDIX A”.• The floor must be solid and level and able to support the
weight of the refrigerator and its contents.• Ensure that any adjacent heat sources, (e.g. furnace exhaust
vent) do not affect the ventilation of the refrigerator.• All joints in the enclosure must be sealed to prevent gas
leakage into the living area.• The enclosure must be free of exposed materials that may
potentially damage the refrigerator, e.g. screw tips, staples, etc.• A wood strip must be in place across the upper opening
of the enclosure. The top frame of the refrigerator will be anchored to the wood strip with screws, see FIG 2.
• The refrigerator must not be installed directly on carpeting:
- Carpeting must be removed or protected by a metal or wood panel beneath the appliance, which extends at least full width and depth of the appliance.
- If the refrigerator is sitting on a wood floor, it is recom-mended that the exposed portion of the floor behind the refrigerator be painted or otherwise protected against incidental moisture that can potentially enter through the refrigerator vents that are installed on the side wall and /or roof of the RV.
• It is required that OEM installed components such as current-carrying conductors (i.e. wiring), plumbing, etc. - except for those required to supply the refrigerator - shall not pass through the refrigerator enclosure except where:
G
K K
L
M
FIG 2 - CLEARANCESWood Strip
FIG 1 - ENCLOSURE
- OEM installed components inside of the refrigerator enclosure are contained outside of the ventilation com-partment by means of permanently securing them (e.g. behind paneling, behind batt-type insulation, inside of paneled storage space above refrigerator) in such a man-ner that OEM installed components will not come into contact with the refrigerator.
- Applications for which there are no alternatives except to have these OEM installed components pass through the ventilation compartment the following requirements must be met: 1) current carrying conductors (120V and 12V) and conductor routing - except for those required to supply the refrigerator - must be protected by conduit, raceway, covering boards or equivalent and in all cases must meet or exceed the requirements of the current publication of NFPA70 and article 551 of the NEC, 2) all OEM installed components shall maintain a mini-mum clearance of 1/2" clearance from the cooling unit to ensure that they will not come into contact with the heated boiler or tubing, 3) the routing of OEM installed components shall not impede the ventilation path for proper operation or combustion, 4) OEM installed com-ponents must not come into contact with the refrigerator mounting rails or frame and the refrigerator should not be modified in any way to accommodate the location or routing of OEM installed components.
CLEARANCESCSA International certification allows the refrigerator to have zero (0) inch minimum clearance at the sides, rear, top, and bottom. While there are no maximum clearances specified for certification, the maximum clearances specified are necessary for correct refrigerator performance.
Failure to adhere to the above installation criteria could cre-ate a combustion hazard.
- 6 -
INSTALLATION PREPARATIONTOP AND SIDES See “APPENDIX A” for rough in dimensions. Dimensions will vary by model. If there is more than 1/4” between either side or the top of the refrigerator and the inside of the refrigerator box, then fill the space with insulation, baffles, or non-flam-mable fabricated seals to avoid trapping heat and sacrificing the performance of the unit. See Insulation note below for additional details.
INSULATION NOTE! - Any insulation used must be securely attached to the enclosure walls and ceiling in order to prevent it from shifting when the refrigerator is installed in enclosure.
- If there is a void space above the refrigerator, insulation should be secured with spray adhesive to the top of the refrigerator to fill the space.
- Trim insulation. Cut it 2-3” shorter than the depth of the refrigerator box, see FIG 3 below.
- Insulation must not come in contact with the cooling unit! Loose insulation can obstruct air flow creating cooling issues and possible damage to the refrigerator.
FIG 3 - INSULATION
Place insulation filling in the space between refrigerator compartment and sides and top of refrigerator.
VENTILATION REQUIREMENTSVentilation is one of the requirements for proper cooling unit operation. Clearances and the use of vents ensure a natural draft which is necessary for good refrigeration. Make sure to read and follow these points:
• Certified installation requires one lower fresh air intake vent and one upper exhaust vent.
• Vents should be centered to the back of the refrigerator. If it is not possible to center the vent, refer to the offset installa-tion, see “OFFSET VENTS”, page 9.
• Safety certification requires specified Dometic vents, see “APPENDIX C”.
• Any obstruction of either of the vent openings is not per-missible, e.g. roof rafters, roofing materials, etc.
• Lower vent: Make sure the opening is even with - or - be-low the floor level to allow any raw LP gas to escape to the outside. NOTE! Floor must not interfere with or block vent openings.
FIG 5 - VENT ABOVE FLOOR LEVEL
When lower vent frame is positioned higher than the refrigerator compart-ment floor, the following is required:
• 2 holes with a diameter of 1-3/4” 1 in2 / hole free area.)
• Cover holes with a screen (min. 14 x 14 per inch)
• Holes must be clear of any obstruction. 1-3/4”
Covered by a screen
COMBUSTION HAZARD. Unburned “Raw” LP gas is heavier-than-air and can collect at floor level creating a combustion hazard.
FIG 4 - LOWER VENT
Side wall
FloorWeep hole
• For vents installed above floor level, additional holes are required to vent these gases to the out-of-doors. Use FIG 5 for details.
2” - 3”
2” - 3”
- 7 -
INSTALLATION PREPARATION
FIG 6 - RECESS DEPTH
FIG 7 - BOX BAFFLE
• The flow of combustion and ventilating air must not be obstructed, e.g. by an open RV door.
• Do not install an awning too close to the upper side vent. Allow a distance of approx. 6-12”.
• The minimum vent height requirements, listed in “AP-PENDIX B”, are part of the safety certification and must be complied with.
RECESS DEPTHSpaces of more than 1”, see FIG 6, from rear wall to the re-frigerator may create performance problems. Fresh air will not pass through the cooling unit which will reduce the efficiency. It is important to check the recess depth and add baffle(s) to increase the movement of air across the coil.
If there is more than 1” between the inside of the ventila-tion compartment and cooling unit, it is required to add box baffle(s) starting above the lower access vent and running perpendicular to the side wall. The baffle should extend up to the ceiling (in board roof vent applications) or up to within 1/2” lower than the condenser fins (roof vent applications). For upper and lower side wall vent applications the baffle should come within 1/2" lower than the condenser fins. This will ensure more efficient operation in warm temperatures. Make sure the baffle is of the same width as the ventilation compart-ment, see FIG 7.
Max 1”(without baffle)
BO
X B
AFF
LE
WATER SUPPLY CONNECTION
REFRIGERATOR MODELS EQUIPPED WITH ICE MAKER, ICE AND WATER DISPENSERSThe water supply system must have a minimum pressure of 15 pounds per square inch gauge (psig). A 1/4” diameter water line to the water valve should be used at the rear of the refrig-erator. The water line must have a manual shutoff valve placed where it is easily accessible.
1/2" Below Fins
Roof Vent ApplicationsInboard Roof VentApplications
BO
X B
AFF
LE
- 8 -
INSTALLATION PREPARATION
VENT APPLICATION TYPES
OFFSET VENTSIf vents must be offset due to interference of building materials the vent must always be offset towards the flue side of the cooling unit. The vent should be centered over the cool-ing unit so that the air can flow up and out of the compartment creating a chimney effect. For offset vent applications, prior written approval and safety certification must be obtained from Dometic Corporation.
FIG 8 - OFFSET VENT UPPER AND LOWER SIDE VENT
FIG 9 - OFFSET VENT SIDE AND ROOF VENT
CENTER OF REFRIGERATOR
CENTER OF REFRIGERATOR
CHOOSING TYPE OF VENT APPLICATIONThere are four types of applications:
• ROOF VENT APPLICATION Recommended for typical installations. Check the enclo-sure depth, see “INSTALLATION PREPARATION > ENCLO-SURE DEPTH” and add a baffle if required. Roof vent in-stallations can also be used when vents are inboard or offset due to radius roof or interference with building materials.
• UPPER AND LOWER SIDE VENT APPLICATION Choose this type of installation when a roof vent installa-tion is not possible. Baffle should be added. The refrigera-tor must be equipped with fan(s).
• ISLAND APPLICATION Intended for refrigerators installed on an inside wall and must be vented through the floor to the ceiling.
• CORNER APPLICATION Intended for refrigerators installed in the rear corner of the vehicle or in an angled cabinet. The refrigerator must be equipped with fan(s).
Please refer to page 30, some fans are optional and not required.
- 9 -
Step Action1 CHECK VENTILATION HEIGHT.
See “APPENDIX B”.
2 CHECK RECESS DEPTH. See “INSTALLATION PREPARATION > RECESS DEPTH”. If required, install a box baffle above the lower access vent.
3 INSTALL LOWER SIDE VENTSee “APPENDIX D”.
ROOF VENT APPLICATIONINSTALL LOWER SIDE VENT AND ROOF VENT
Minimum Ventilation Height
BO
X B
AFF
LE
RECESS DEPTH
4 INSTALL ROOF VENT• OptiOn 1 - typical
See “APPENDIX D”.
• OptiOn 2 - inbOard Inboard installs due to radius roof or interference with building material.
BO
X B
AFF
LE
RECESS DEPTH
BO
X B
AFF
LE
RECESS DEPTH
VENT APPLICATION TYPES
- 10 -
VENT APPLICATION TYPES
Step Action1 CHECK VENTILATION HEIGHT.
See “APPENDIX B”.
2 CHECK RECESS DEPTH. See “INSTALLATION PREPARATION > RECESS DEPTH”. If required, install a box baf-fle above the lower access vent extending within 1/2” lower than the condenser fins as shown in the picture below.
3 INSTALL LOWER SIDE VENT.See “APPENDIX D”.
4 INSTALL UPPER SIDE VENT. See “APPENDIX D”.
UPPER AND LOWER SIDE VENT APPLICATIONINSTALL UPPER AND LOWER SIDE VENTS
ISLAND APPLICATIONACCESS PANEL
• A sealed access panel is required when using this system in conjunction with below floor ventilation. Access is necessary to complete gas connections, gas leak tests, and periodic service requirements at the rear of the refrigerator.
Access panel dimensions
• If the refrigerator is located within the vehicle interior it must be completely sealed to prevent products of com-bustion or raw gas leakage within the living space! If it is placed alongside the sidewall and floor ventilation is provided, rear access is still required.
• The door or panel should prevent water entry.
DUCTAn air duct extends downwardly from the refrigerator through a floor of the vehicle. If the refrigerator is not equipped with a fan, a fan must be installed in the duct to aid air circulation. Air for cooling the condenser and absorber is drawn up the duct from outside the vehicle and exhausted outside the vehi-cle through an upper duct and vent in a roof of the vehicle. The duct must be centered horizontally on the back of the refrigerator and should have the following dimensions:
Length (L): 11-34” min - max valuesWidth (W): 6.5” Depth (D): 4-54” min - max values
Fan(s)*Minimum Ventilation Height
* Fan(s) position may vary by model.
BO
X B
AFF
LE
RECESS DEPTH
FIG 10 - DUCT DIMENSIONS
D
L
W
Center Fan Horizontally Min 3”
Max 8”
1/4” x 0.025 metal mesh
22”
14”
- 11 -
VENT APPLICATION TYPESISLAND APPLICATION CONT'DINSTALL DUCT AND ROOF VENT
Step Action1 CHECK VENTILATION HEIGHT.
See “APPENDIX B”.
2 CHECK RECESS DEPTH.See “INSTALLATION PREPARATION > RECESS DEPTH”. If required, install a box baffle above the lower access vent. Box baffle must be positioned no lower than access panel.
Minimum Ventilation Height
DUCT AND FAN
ACCESS PANEL{
ACCESS PANEL
DUCT AND FAN
RECESS DEPTH
3 INSTALL ACCESS PANEL
4 INSTALL DUCT
5 INSTALL ROOF VENTSee “APPENDIX D”.
CORNER APPLICATIONOPTION 1 - INSTALL LOWER SIDE VENT AND ROOF VENT
Step Action1 CHECK VENTILATION HEIGHT.
See “APPENDIX B”.
2 CHECK RECESS DEPTH. See “INSTALLATION PREPARATION > RECESS DEPTH”. A box baffle is required above the lower access vent.
Minimum Ventilation Height
RECESS DEPTH
- 12 -
OPTION 2 - INSTALL UPPER AND LOWER SIDE VENTS
Step Action1 CHECK VENTILATION HEIGHT.
See “APPENDIX B”.
2 CHECK RECESS DEPTH. See “INSTALLATION PREPARATION > RE-CESS DEPTH”. A box baffle is required above the lower access vent.
3 INSTALL LOWER SIDE VENT.See “APPENDIX D”.
4 INSTALL UPPER SIDE VENT. See “APPENDIX D”.
VENT APPLICATION TYPES
Roof vent opening must be a mini-mum of 110 in2 unobstructed free area.
Rafters
3 INSTALL LOWER SIDE VENT.See “APPENDIX D”.
4 INSTALL ROOF VENTSee “APPENDIX D”.
RECESS DEPTH
Fan*
Minimum Ventilation Height
* Fan position may vary by model.
BAFFLE
UPPER SIDE VENT
LOWER SIDE VENT
- 13 -
INSTALLING THE REFRIGERATOR Be careful when installing the refrigerator model NDM1062. It is equipped with the latest vacuum insulated panel technology. The insulating panels are located on the top, back, bottom, sides and doors. If the surface is punctured, loss of insulation will occur, resulting in poor refrigerator performance.
For a proper installation, follow these instructions:
• Carefully place the refrigerator in the enclosure.
• Verify that there is a complete seal between the front frame of the refrigerator and the top, sides and bottom of the enclosure. A length of sealing strip is applied to the rear surface of the front frame for this purpose. The sealing strip should provide a complete isolation of the appliance’s combustion system from the vehicle interior. RM2351, RM2354, RM2410 and RM2510: Apply a seal-ing strip to the foremost floor of the enclosure, see FIG 11.Be careful not to damage the sealing strip when the refrigerator is put in place!RM2351 & RM2354: Do NOT remove the factory in-stalled sealing strip at top rear corner of cabinet. It is NOT part of the shipping package and must be left intact. See FIG 11.
SECURING THE REFRIGERATORIt is important to follow the sequence in securing refrigerator in enclosure since failure in doing so can cause leakage be-tween the frame and cabinet. After the refrigerator is put in place (ensuring a combustion seal at the front frame), the refrigerator is to be secured in the enclosure with screws (not included).
RM2351 & RM2354Install the five screws in the following order:
1. Four screws installed through the front frame. (To cover the screw heads, use the plugs in the parts bag.)
2. One screw installed in the rear base.
2
1
INSTALLATION PROCEDURE
General view. Features may vary by model.
FIG 12 - RM2451, RM2454, RM2551, RM2554, DM2652, DM2662, DM2663, DM2852, DM2862, RM3762, RM3962, NDM1062, RM1350, RM1350SL & NDA1402
FIG 13 - SECURING RM2351 & RM2354
Sealing Strip
Do NOT Remove Factory Installed Sealing Strip
FIG 11 - RM2351, RM2354, RM2410 & RM2510
Apply sealing strip along floor here. Sealing strip must be width of enclosure.
RM2351 & RM2354:Do NOT Remove Factory InstalledSealing Strip
- 14 -
RM2410 & RM2510Install the six screws in the following order:
1. Two screws installed through the front base.2. Two screws installed in the top frame.3. Two screws installed in the rear base.
INSTALLATION PROCEDURE
FIG 14 - SECURING RM2410 & RM2510
FIG 15 - SECURING RM2620 & RM2820
Sealing Strip
3 rd.
2 nd.
1 st.
4 th.
1 st.
2 nd.3 rd.
RM2620 & RM2820Install the screws in the following order:
1. Two screws installed through the front base.2. Two screws installed in the top frame.3. Two screws installed in the rear base. 4. Attach lower front strip after the refrigerator is set
into the cutout opening.
- 15 -
INSTALLATION PROCEDURERM2451, RM2454, RM2551, RM2554, DM2652, DM2662, DM2663, DM2852, DM2862, RM3762, RM3962, RM1350, RM1350SL, NDA1402 & NDM1062Install the screws in the following order:
1. TWO SCREWS INSTALLED THROUGH THE FRONT BASE. The refrigerator is provided with a lower front strip (shipped as a loose part). Attach the front strip after the refrigerator is set into the cutout opening.
a) Install the lower front strip by sliding it under the bottom hinge plate(s).
Models with 1 Hinge Plate The hinge plate can be located on the left or right side depending on the door swing. Slip under the hinge and swing into place.
Models with 2 Hinge Plates
Models with 2 Hinge PlatesOne screw through each hinge.
b) Secure the refrigerator and the lower front strip with two screws.
Models with 1 Hinge Plate One screw through the hinge and on the opposite side and then, one screw through the lower front strip.
- 16 -
3. ONE SCREW INSTALLED IN THE REAR BASE. OPTIONAL SCREW MAY BE ADDED. RM2451, RM2454, RM2551, RM2554, DM2652, DM2662, DM2663, DM2852, DM2862, RM3762, RM3962 & NDM1062 RM1350. RM1350SL & NDA1402
DRAIN WATER HOSE• Hose must not contact the boiler casing.• Hose must not be kinked.• Hose must not be routed uphill at any point.• Perforated plug must be present at end of hose.
OPTION 1 - THROUGH FLOORDrill hole through flooring, see FIG 16. Seal around hole. Check to make sure the supplied hose is long enough – if not, installer will have to supply extra length of hose.
Ice Maker Cord (optional)
2. TWO SCREWS INSTALLED IN THE TOP FRAME. RM2451, RM2454, RM2551, RM2554, DM2652, DM2662, DM2663, DM2852, DM2862 & NDM1062
a) Gently push the tabs out of the hole in the hinge with a flat blade screwdriver (both sides).
b) Carefully tilt the top decoration panel and lift to remove from top frame. Be careful not to damage the circuit board and wires.
c) Install the two screws in the top frame, the holes are accessible from underneath.
d) Seal the opening for the screws with aluminum tape.
e) Replace the top decoration panel. Be careful not to pinch the wires behind the panel. Make sure the tabs snap back into the holes in the hinge plate.
RM3762, RM3962, RM1350, RM1350SL & NDA1402Fasten the refrigerator with two screws through the holes underneath the top decoration panel.
Hole for drain water hose
Boilercasing
Hos
e
INSTALLATION PROCEDURE
2
1
General view. Features may vary by model.
General view. Features may vary by model.
General view. Features may vary by model.
Optional Screw
FIG 16 - DRAIN WATER HOSE
- 17 -
OPTION 2 - THROUGH VENT FRAME (PLASTIC VENTS ONLY)Pull end of hose through louvers in vent door. Cut hoseto length. Reinstall perforated plug.
OPTION 3 - HANGING CLIP (PLASTIC VENTS ONLY)Install clip (part number 3106559.xxx) during vent installa-tion. Insert hose into “j” portion of clip. Cut hose to length. Reinstall perforated plug. Hose should be positioned to drain into uppermost row of louvers in vent door.
OPTION 4 - THROUGH VENT DOOR (SIDE-BY SIDE PLASTIC VENT ONLY)Drill a 5/8” hole in vent frame directly above floor line. Route drain hose through hole and cut to length. Reinstall perforated plug on the outside of the vent frame. Apply sealant around plug to ensure water does not seep into enclosure.
CONNECTIONS
GAS CONNECTIONHook up to the gas supply line is accomplished at the manual gas valve, which is furnished with a 3/8” SAE (UNF 5/8” -18) male flare connection. ALWAYS use a back-up wrench when loosening and tightening gas connections. All completed con-nections should be examined for leaks using an approved leak detection solution.
The gas supply system must incorporate a pressure regulatorto maintain a supply pressure of not more than 11 inches water column. When testing the gas supply system at test pressures:
• > 1/2 psi - the refrigerator and its individual shutoff valve must be disconnected from the gas supply piping system.
• ≤ 1/2 psi - the appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve.
If detailed instructions on the installation and connection tothe gas supply are required, please contact your dealer or distributor.
INSTALLATION PROCEDURE
All connections should be routed to avoid direct contact with boiler casing, burner cover, or any other components of refrigerator.
EXPLOSION HAZARD. Never use an open flame to check for gas leaks. Failure to obey this warn-ing could cause an explosion resulting in death or severe personal injury.
ELECTRICAL CONNECTION 120 VAC CONNECTIONThe refrigerator is equipped with a grounded three-prong plug for protection against shock hazards. It should be plugged di-rectly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug!The free length of the cord is 2 feet. To allow easy access through the vent door, it is recommended to install the recep-tacle on the opposite side of the burner assembly and approx. 3-6” above the refrigerator mounting floor.
General view. Features may vary by model.
3-6”
120 VACReceptacle
FIG 17 - 120 VAC CONNECTION
- 18 -
INSTALLATION PROCEDURE12 VDC CONNECTION RM2451, RM2551, DM2652, DM2852, RM3762, RM3962, RM1350, RM1350SL & NDA1402: These refrigerator models are not designed for 12V DC operation of the cooling system. However, 12V DC must be supplied to operate the controls. RM2354, RM2454, RM2554, DM2662, DM2663, DM2862 & NDM1062: These refrigerator models require a continuous 12 VDC supply to maintain the automatic energy system.
The connection is made to the positive (+) and negative (-) terminals of the terminal block on back of the refrigerator. Correct polarity must be observed when connecting to the DC supply. Do not use the chassis or vehicle frame as one of the conductors. Connect two wires at the refrigerator and route to the DC supply. Ensure the connections are clean, tight and free from corrosion.For 3-way models, the voltage drop affects the wattage output of the 12 V cartridge heater and the refrigerator performance. The 12 VDC heater is fused with a 30 amp. in-line blade fuse.Ensure that the wires from the battery to the refrigerator are able to handle the load. Recommended wire sizes are dis-played in the table below.
MAXIMUM WIRE LENGTHWIRE
MODELSize LengthAWG ft
RM2351, RM2451RM2551, DM2652DM2662, DM2852DM2862, RM3762RM3962, NDM1062RM1350, RM1350SL,NDA1402
14
12
17
27
RM2354, RM2454RM2554, DM2663
10
8
17
27
ALTERNATOR (D+) CONNECTION RM3762, RM3962, RM1350 & RM1350SL (with the auto-matic door locking system)The refrigerator requires the connection of a signal wire from the alternator (D+) in order to maintain the automatic door travel latch for RM1350, and RM1350SL and the temporary gas lockout function. The gas operation will automatically be locked out for a period of 15 minutes when the engine is switched off. This will prevent gas operation e.g. when stop-ping at a refueling station.
Connect the vehicles alternator (D+) to the D+ on the terminal block.
Battery
B+
Alternator signal wire to the refrigerator D+
ALTERNATOR
Ignition switch
Charge light
D+ (Alternator signal wire) Valid for refrigerator models with the automatic door lock-ing system.
FIG 18 - ALTERNATOR CONNECTION
- 19 -
INSTALLATION PROCEDUREDOOR AND HANDLE MOUNTING INSTRUCTIONS REVERSING THE DOOR SWINGRM2351, RM2354, RM2451, RM2454, RM2551, RM2554, DM2652, DM2662, DM2663, RM3762, DM2852, DM2862, RM3962, NDM1062 & NDA1402A special hinge kit must be used in order to change the door swing. For conversion kit number, please contact service point or distributor service department.
RM2410 & RM2510The refrigerator is equipped with hinges that make it possible to change the direction the door opens by moving the hinges to the opposite side. To change the door hinges from one side to the other, follow these steps:
1. Open the door and remove the two screws hold-ing the top decoration. (The screws are accessible from beneath.)
2. Remove the top hinge pin and lift out the door.3. Unscrew the bottom hinge pin. 4. Remove the plastic cap from the opposite lower
hinge and place it in the hole just “left empty” by the lower hinge pin.
5. Screw the lower hinge pin in the hole from which the plastic cap was removed.
6. Before replacing the door on the refrigerator, remove the catches and move them to the opposite side of the cabinet.
7. The holes are covered with plastic caps that must be removed and inserted in the holes that previ-ously held the catches.
8. Unscrew the handle and move it to the opposite side of the door.
9. Insert the plastic caps into the holes left open on the door. (Plastic caps for empty holes are in the parts bag inside the refrigerator.)
10. Remount the door and hinge pins in the reverse order of their removal.
11. Before the top decoration is refitted, check that the door closes easily and the gasket seals well on all sides.
FIG 19 - RM2410 & RM2510, REVERSING THE DOOR SWING
- 20 -
INSTALLATION PROCEDURE
PANEL DIMENSIONS MAX. THICKNESS 5/32”
HEIGHT
MAX MIN
WIDTH
MAX MIN
UPPER DOOR
DM2652 DM2662 DM2663DM2852 DM2862 NDM1062
15-27/32 15-25/32 20-3/4 20-5/8
RM2620 12-3/64 11-31/32 20-9/32 20-13/64
RM2820 14-7/8 14-51/64 22-11/64 22-3/32RM3762RM3962 17-3/64 16-31/32 23-25/32 23-11/16
LOWER DOOR / SINGLE DOOR
RM2351RM2354 26-17/64 26-3/16 19-5/8 19-17/32
RM2410 27-7/16 27-23/64 20-9/32 20-13/64
RM2510 35-5/16 35-15/64 20-9/32 20-13/64
RM2620 32-1/4 32-5/32 20-9/32 20-13/64
RM2820 35-5/16 35-15/64 22-11/64 22-3/32RM2451RM2454DM2652 DM2662 DM2663
32-9/16 32-1/2 20-3/4 20-5/8
RM2551RM2554DM2852 DM2862 NDM1062
38-11/16 38-5/8 20-3/4 20-5/8
RM3762 32-7/16 32-23/64 23-25/32 23-11/16
RM3962 41-39/64 41-9/16 23-25/32 23-11/16
INSTALLING THE DOOR PANEL(S) Before starting the mounting work, read this section thorough-ly. Make sure the panel dimensions are in compliance with those given in “PANEL DIMENSIONS”. After having mounted the panel(s) as described in “MOUNTING INSTRUCTIONS”, install the handles. For installation instructions for RM3762 & RM3962 (stainless steel doors) and for NDM1062, see “IN-STALLING THE DOOR HANDLES”.
DOOR PANEL DIMENSIONS
RM2351, RM2354, RM2410, RM2451, RM2454, RM2510, RM2620, DM2652, DM2662, DM2663, RM2551, RM2554, RM3762, RM2820, DM2852, DM2862, RM3962 & NDM1062
RM2620 & RM2820To change the door hinges from one side to the other, follow these steps:
1. Open the upper door and remove the two screws holding the top decoration. (The screws are acces-sible from beneath.)
2. Remove the top hinge pin and lift out the door.3. Remove center hinge pin and lift out the lower door.4. Unscrew the bottom hinge pin. 5. Remove the plastic cap from the opposite lower
hinge and place it in the hole just “left empty” by the lower hinge pin.
6. Screw the lower hinge pin in the hole from which the plastic cap was removed.
7. Before replacing the doors on the refrigerator, remove the catches and move them to the opposite side of the cabinet. The holes are covered with plastic caps that must be removed and inserted in the holes that previously held the catches.
8. Unscrew the handles and move them to the opposite side of the door.
9. Insert the plastic caps into the holes left open on the doors. (Plastic caps for empty holes are in the parts bag inside the refrigerator.)
10. Remount the doors and hinge pins in the reverse order of their removal.
11. Before the top decoration is refitted, check that the door closes easily and the gasket seals well on all sides.
FIG 20 - RM2620 & RM2820, REVERSING THE DOOR SWING
- 21 -
INSTALLATION PROCEDUREDOOR PANEL DIMENSIONS CONT'DRM1350
PANEL DIMENSIONS MAX. THICKNESS 5/32"
HEIGHT
MAX MIN
WIDTH
MAX MIN
UPPER DOORRM1350MRM1350SLMRM1350MIMRM1350WIM RM1350WID (left)
19-7/32 19-9/64 15-43/64 15-19/32
RM1350WID (right) 9-9/32 9-13/64 15-43/64 15-19/32
LOWER DOORRM1350MRM1350SLMRM1350MIMRM1350WIM (right)RM1350WID
40-1/32 39-31/32 15-43/64 15-19/32
RM1350WIM (left)
f
c
d
b
a
ea b
max min max min
5-63/64 5-29/32 9-49/64 9-11/16
c dmax min max min
11-55/64 11-49/64 28-17/64 28-3/16
e fmax min max min
15-43/64 15-19/32 40-1/32 39-31/32
NDA1402
MODELS EQUIPPED WITH ICE MAKER Freezer door Refrigerator door
11.181(284)
15.237(387)
)5.196( 422.72))5.497( 972.13(
5̊4
)5.7( 592.
)0251( 248.95
493.791. +890. –
01(5+
)5.2–
.197(2x) (5)(2x)
MAX 1.00(MAX 25) MAX 1.00
(MAX 25)
)5.7( 592.
5̊4
.197 (2x) (5)(2x)
493.791. +890. –
01(5+
)5.2–
16.811(427)
12.756(324)
)5.217( 150.82
))5.518( 601.23(
)0251( 248.95
Freezer door Refrigerator door
11.181(284)
15.237(387)
)5.196( 422.72))5.497( 972.13(
5̊4
)5.7( 592.
)0251( 248.95
493.791. +890. –
01(5+
)5.2–
.197(2x) (5)(2x)
MAX 1.00(MAX 25) MAX 1.00
(MAX 25)
)5.7( 592.
5̊4
.197 (2x) (5)(2x)493.
791. +890. –
01(5+
)5.2–
16.811(427)
12.756(324)
)5.217( 150.82
))5.518( 601.23(
)0251( 248.95
FIG 21 - PANEL DIMENSIONS FOR THE FREEZER DOOR
FIG 22 - PANEL DIMENSIONS FOR THE FRIDGE DOOR
- 22 -
Freezer door Refrigerator door
11.181(284)
15.237(387)
)5.196( 422.72
˚54
)5.7( 592.493.
791. +
890. –01(
5+
)5.2–
.197(2x) (5)(2x)
MAX 1.00(MAX 25)
MAX 1.00(MAX 25)
)5.7( 592.
˚54
.197 (2x) (5)(2x)
493.791.
+890. –
01(5
+)5.2–
16.811(427)
12.756(324)
)5.217( 150.82
))5.518( 601.23(
)0251( 248.95
)5.7( 592.
)083( 069.41
.197(2x) (5)(2x)
MAX 1.00(MAX 25)
493.791.
+890. –
01(5
+)5.2–
.913 (23.2) 9.370 (238)
)067( 129.92
INSTALLATION PROCEDUREDOOR PANEL DIMENSIONS CONT'DNDA1402MODELS EQUIPPED WITH ICE DISPENSER / ICE & WATER DIS-PENSERS Freezer door Refrigerator door
11.181(284)
15.237(387)
)5.196( 422.72
˚54
)5.7( 592.493.
791. +
890. –01(
5+
)5.2–
.197(2x) (5)(2x)
MAX 1.00(MAX 25)
MAX 1.00(MAX 25)
)5.7( 592.
˚54
.197 (2x) (5)(2x)
493.791.
+890. –
01(5
+)5.2–
16.811(427)
12.756(324)
)5.217( 150.82
))5.518( 601.23(
)0251( 248.95
)5.7( 592.
)083( 069.41
.197(2x) (5)(2x)
MAX 1.00(MAX 25)
493.791.
+890. –
01(5
+)5.2–
.913 (23.2) 9.370 (238)
)067( 129.92Freezer door Refrigerator door
11.181(284)
15.237(387)
)5.196( 422.72
˚54
)5.7( 592.493.
791. +
890. –01(
5+
)5.2–
.197(2x) (5)(2x)
MAX 1.00(MAX 25)
MAX 1.00(MAX 25)
)5.7( 592.
˚54
.197 (2x) (5)(2x)
493.791.
+890. –
01(5
+)5.2–
16.811(427)
12.756(324)
)5.217( 150.82
))5.518( 601.23(
)0251( 248.95
)5.7( 592.
)083( 069.41
.197(2x) (5)(2x)
MAX 1.00(MAX 25)
493.791.
+890. –
01(5
+)5.2–
.913 (23.2) 9.370 (238)
)067( 129.92
FIG 23 - PANEL DIMENSIONS FOR THE FREEZER DOOR FIG 24 - PANEL DIMENSIONS FOR THE FRIDGE DOOR
- 23 -
RM2410, RM2510, RM2620 & RM2820To install the door panel, follow these steps:
1. Open the door 90 degrees. 2. Locate decoration strips. On some refrigerators, the
decoration strip is taped inside the door; if installed on the door, remove the door decoration strip (2) by removing its two screws (1).
3. Insert one vertical edges into the groove of the door frame (3).
4. Bend the panel gently so that the free side of the panel can be slipped into the corresponding groove of the door frame (4). Slide the panel down into the groove of the bottom frame (5).
5. Between the upper edge of the panel and the door frame there is a gap which should be covered by the decoration strip.
6. Put the decoration strip across the door so that the gap is covered and push it upward (6). The tabs on the inside of the strip should fit behind the flange of the door frame.
7. Secure the decoration strip with the two screws removed in step 1.
DOOR PANEL INSTALLATION CONT'DMOUNTING INSTRUCTIONSRM2351, RM2354, RM2451, RM2454, RM2551, RM2554, DM2652, DM2662, DM2663, DM2852, DM2862 & NDM1062
To install the panel(s), follow these steps:
1. Open the door 90 degrees. 2. Locate decoration strips. These are taped to one of
the shelves or to the inside of the door. Loosen tape and remove strips.
3. Insert the vertical edges into the grooves of the door frame. Push the panel downwards so that the lower horizontal edge of the panel is fitted into the bot-tom groove (FIG 25).
4. Fasten the decoration strips: - Screws: Secure decoration strip with three screws (FIG 26).
- Snap-in: Snap in the decoration strips (FIG 27).
INSTALLATION PROCEDURE
1
2
2
1 1 1
2
1 1 1FIG 26
FIG 27
33
4
5
FIG 25
1 1 2
3 4
5
6
1 1
FIG 28 - DOOR PANEL
- 24 -
INSTALLATION PROCEDUREDOOR PANEL INSTALLATION CONT'DRM3762 & RM3962To install the door panels, follow these steps:
1. Remove the decoration strip by inserting a finger in the plastic profile and pull.
2. Open the door 90 degrees. 3. Insert the door panel’s edges into the grooves of the
door frame. Push the panel sideways until the edge of the panel is fitted into the opposite side groove.
4. Snap on the decoration strip.
1 2
5. Snap on the handle.
REPLACING THE DOOR PANELSTo replace a mounted door panel, follow these steps:
1. Detach the handle by using a flat blade screwdriver to gently push the two tabs away.
2. Remove decoration strip and door panel. 3. Install the new panel according to the previous
instruction, steps 3-5.
- 25 -
5. Put back the decoration strip. Slide (A) or snap (B) into place.
6. Slide the handle into place (A) and attach with the screw (B).
INSTALLATION PROCEDUREDOOR PANEL INSTALLATION CONT'DRM1350 & RM1350SLTo install the door panels, follow these steps:
1. Open the door.2. Remove the screw (A). Slide off the handle (B).*
3. Slide off the decoration strip.
4. Insert the door panel’s edges into the grooves of the door frame. Push the panel side-ways until the edge of the panel is fitted into the opposite side groove.
* For RM1350WID it is not necessary to remove the right freezer door handle in order to mount the door panel.
A
B
AB
A
B
- 26 -
INSTALLATION PROCEDURE
NDA1402MODELS EQUIPPED WITH ICE DISPENSER / ICE & WATER DISPENSERS
DOOR PANEL INSTALLATION CONT'D
NDA1402MODELS EQUIPPED WITH ICE MAKER
Freezer door
Refrigerator door
Freezer door
Refrigerator door
- 27 -
NDM1062To install the door handles, follow these steps:
1. Locate the plastic bag containing the handles and screws.
2. Open freezer door.3. Position handle. Align the holes in the
handle with the holes in the frame.
4. While holding handle firmly against the door, fasten screws with a Phillips screwdriver. Close the door.
INSTALLATION PROCEDURE
Door insert panels Stainless steel doors
5. Open fridge door and repeat steps 3 and 4 to install the second handle.
INSTALLING THE DOOR HANDLESRM3762 & RM3962 - Stainless steel doorsTo install the door handles, follow these steps:
1. Snap on the handle by inserting its two tabs in the slot and slide into place.
2. Attach the handle with two screws.
- 28 -
APPENDIX A - OVERALL & ROUGH IN DIMENSIONSFOR ENCLOSURE
1 Steel doors2 Door insert panels3 Add 1” depth for units with one or two optional ventilator fans.4 Units with factory installed fans may require 1” additional depth.
OVERALL DIMENSIONS ENCLOSURE DIMENSIONSMODEL Height (A) Width (B) Depth (C) Height (H) Width (W) Depth (D)
RM2351 30-5/32 21-7/8 22-22/32 29-3/4 20-1/2 21-1/2
RM2354 30-5/32 21-7/8 22-22/32 29-3/4 20-1/2 21-1/2
RM2410 33-1/2 22-53/64 24-7/8 32-7/16 21-13/16 24-7/32
RM2451 37-3/8 24-7/8 24-11/16 36-1/2 23-11/16 24
RM2454 37-3/8 24-7/8 24-11/16 36-1/2 23-11/16 24
RM2510 40-29/32 22-53/64 24-7/8 40-5/16 21-13/16 24-7/32
RM2551 43-1/2 24-7/8 24-11/16 42-5/8 23-11/16 24
RM2554 43-1/2 24-7/8 24-11/16 42-5/8 23-11/16 24
RM2620 51-31/32 22-23/32 24-9/16 49-17/32 21-13/16 24-7/32
DM2652 54-21/32 24-7/8 26-1/32 53-3/4 23-11/16 243
DM2662 54-21/32 24-7/8 26-1/32 53-3/4 23-11/16 243
DM2663 54-21/32 24-7/8 26-1/32 53-3/4 23-11/16 243
RM3762 54-3/4 25-5/64 26-1/16 53-3/4 23-11/16 243
RM2820 57-7/8 24-39/64 24-9/16 55-7/16 23-11/16 243
DM2852 60-51/64 24-7/8 26-1/32 59-15/16 23-11/16 243
DM2862 60-51/64 24-7/8 26-1/32 59-15/16 23-11/16 243
RM3962 63-15/16 25-5/64 26-1/16 62-61/64 23-11/16 243
NDM1062 60-54/64 24-7/8 26-5/8 59-15/16 23-11/16 243
RM1350 64-17/64 33-11/16 28-1/161 , 29-1/22 63-3/16 32-3/4 26-1/164
RM1350SL 64-17/64 33-11/16 26-1/161,27-1/22 63-3/16 32-3/4 24-1/164
NDA1402 64-17/64 33-11/16 29-5/8 63-3/16 32-3/4 26-1/164
SIDE VIEW VIEW FROM ABOVE
D
H AA
B
C
D
WB
C
- 29 -
APPENDIX B - MINIMUM VENTILATION HEIGHTSMINIMUM VENTILATION HEIGHTS
B1 = ROOF VENT & LOWER SIDE VENT
B2 = UPPER & LOWER SIDE VENT
RM2351 B1 31
B2 28
RM2354B1 31
B2 28
RM2410B1 34
B2 38
RM2451B1 37-3/4
B2 36
RM2454B1 37-3/4
B2 36
RM2510B1 42
B2 38
RM2551B1 44-1/2
B2 42
RM2554B1 44-1/2
B2 42
RM2620B1 57-3/4
B2 49
DM2652B1 57-3/4
B2 56
DM2662B1 57-3/4
B2 56
DM2663B1 57-3/4
B2 56
RM3762B1 57-3/4
B2 56
RM2820B1 63-3/4
B2 57
DM2852B1 63-3/4
B2 61
DM2862B1 63-3/4
B2 61
RM3962B1 66-13/16
B2 63
NDM1062B1 63-3/4
B2 61
RM1350B1 69-1/8
B2 63
RM1350SLB1 69-1/8
B2 63
NDA1402B1 69-1/8
B2 63
Minimum Ventilation Height
B1 ROOF VENT & LOWER SIDE VENT
B2 UPPER & LOWER SIDE VENT
Fan(s)*Minimum Ventilation Height
* Fan(s) position may vary by model.
NOTE! Ventilation height should be measured from the seam between the frame and door of the lower side wall vent to the top of the roof opening (B1) or to top of the uppermost row of louvers on the upper side wall vent (B2).
- 30 -
APPENDIX C - APPROVED VENTSRefer to the table below for information on which vents and fans (if applicable) to use. The part numbers are displayed on pages 32-34.
Start by locating the refrigerator model in question, e.g. RM2351 and then, select vent application type. In this case, numbers 1 and 2 indicate that Roof Vent (1) and Side Vent (2 or 3) could be installed. As another example, when selecting model DM2652 with an upper and lower side vent application, use Upper Side Vent (2 or 3) and Lower Side Vent (2 or 3).
INST. TYPE
MODEL
ROOF VENT APPLICATION
UPPER & LOWER SIDE APPLICATION
ISLAND APPLICATION
CORNER APPLICATION
Roof Vent
Lower Side Vent
Fan Upper Side Vent
Lower Side Vent
Fan Roof Vent
Fan Roof Vent
Upper Side Vent
Lower Side Vent
Fan
RM2351 1 2, 3 9** 8, 4*, 5* 8, 6* 9** 1 9 1 8, 5** 8, 6* 9RM2354 1 2, 3 9** 8, 4*, 5* 8, 6* 9** 1 9 1 8, 5** 8, 6* 9RM2410 1 2, 3 9** 2, 3, 8*, 5* 2, 3, 8*, 6* 9** 1 9 1 2, 3, 8*, 5* 2, 3, 8*, 6* 9RM2451 1 2, 3 9** 2, 3, 8*, 5* 2, 3, 8*, 6* 9** 1 9 1 2, 3, 8*, 5* 2, 3, 8*, 6* 9RM2454 1 2, 3 9** 2, 3, 8*, 5* 2, 3, 8*, 6* 9** 1 9 1 2, 3, 8*, 5* 2, 3, 8*, 6* 9RM2510 1 2, 3 9** 2, 3, 8*, 5* 2, 3, 8*, 6* 9** 1 9 1 2, 3, 8*, 5* 2, 3, 8*, 6* 9RM2551 1 2, 3 9** 2, 3, 8*, 5* 2, 3, 8*, 6* 9** 1 9 1 2, 3, 8*, 5* 2, 3, 8*, 6* 9RM2554 1 2, 3 9** 2, 3, 8*, 5* 2, 3, 8*, 6* 9** 1 9 1 2, 3, 8*, 5* 2, 3, 8*, 6* 9RM2620 1 2, 3 10** 2, 3 2, 3 10 1 10 1 2, 3 2, 3 10DM2652 1 2, 3 10** 2, 3 2, 3 10 1 10 1 2, 3 2, 3 10DM2662 1 2, 3 10** 2, 3 2, 3 10 1 10 1 2, 3 2, 3 10DM2663 1 2, 3 10** 2, 3 2, 3 10 1 10 1 2, 3 2, 3 10RM3762 1 2, 3 10** 2, 3 2, 3 10 1 10 1 2, 3 2, 3 10RM2820 1 2, 3 10** 2, 3 2, 3 10 1 10 1 2, 3 2, 3 10DM2852 1 2, 3 10** 2, 3 2, 3 10 1 10 1 2, 3 2, 3 10DM2862 1 2, 3 10** 2, 3 2, 3 10 1 10 1 2, 3 2, 3 10RM3962 1 2, 3 10** 2, 3 2, 3 10 1 10 1 2, 3 2, 3 10NDM1062 1 2, 3 10** 2, 3 2, 3 10 1 10 1 2, 3 2, 3 10RM1350 1 7 *** 7 7 *** 1 *** 1 7 7 ***RM1350SL 1 7, 2, 3 *** 7, 2, 3 7, 2, 3 *** 1 *** 1 7, 2, 3 7, 2, 3 ***NDA1402 1 7 *** 7 7 *** 1 *** 1 7 7 ***
*Optional vents may be used in applications where the preferred vent cannot be used.
**Optional fan. Note that some models can be purchased with factory installed fan(s).
***Fan(s) are factory installed on these models.
- 31 -
APPENDIX C - APPROVED VENTS
*Suffix “xxx” should be replaced by a color code
PLASTIC ROOF VENT UPPER & LOWERPLASTIC SIDE VENT
1 2
3 4
No 3311236.xxx* No 3109350.xxx*
Cutout: 6-1/2” x 23-3/4” Cutout: 13-3/4” x 21-9/16”
UPPER METAL SIDE VENT
No 3100451.xxx*
Cutout: 7-3/4” x 19-1/4”
UPPER & LOWERPLASTIC SIDE VENT
No 13001No 13003
Cutout: 13-3/4” x 21-9/16”
- 32 -
APPENDIX C - APPROVED VENTS
*Suffix “xxx” should be replaced by a color code
5 6
UPPER & LOWER PLASTIC SIDE VENT
8
No 3109492.xxx*
Cutout: 9-11/16” x 19-1/4”
UPPER & LOWER PLASTIC SIDE-BY-SIDE VENT
7
No 3109349.xxx*
Cutout: 13-5/8” x 28-5/8”
LOWER METAL SIDE VENT
No 3102364.xxx*No 8030211.xxx*
Cutout: 9-11/16” x 19-1/4”
UPPER METAL SIDE VENT
No 8030122.xxx*
Cutout: 10-1/4” x 21”
- 33 -
*Patent #5,355,693
FAN(INNOVATOR REFRIGERATOR
VENTILATION SYSTEM*)
FAN(INNOVATOR REFRIGERATOR
VENTILATION SYSTEM*)
9
11
Part No 3108705.751 Part No 3108705.744
Z-BRACKET
APPENDIX C - APPROVED VENTS CONT'D
Wall or Frame
"D" "D"
"Z" Bracket
VentFrame
VentFrame
"Z" Bracket
"Z" Bracket 3103812.XXXUse appropriate "D"XXX = 016 = .62"XXX = 024 = .81"XXX = 040 = .19"
Wall or Frame
10
- 34 -
Reference “APPENDIX C” for Approved Vents.
All fasteners referenced herein are to be provided by the installer. The screw types selected should be appropriate for the application for which they are being used. For example; wood screw thread type for wood engagement, self tap-ping screw thread type for metal engagement, and plastic screw thread type for plastic engagement. Unless otherwise noted, minimize lengths to fit applications appropriately. Rivets are acceptable for use only where noted.
• APPLY SEALANT AROUND THE THREAD OR RIVET BODY OF ALL FASTENERS.• APPLY DRY SEALANT AROUND SURFACE MOUNTING FACE OF ALL VENT FRAMES OR VENT
BASES PRIOR TO INSTALLATION.• APPLY WET SEALANT AROUND PERIMETER OF ALL VENT FRAMES OR VENT BASES AFTER
INSTALLATION. ENSURE THAT SEALANT DOES NOT BLOCK THE MOLDED WEEP TRACKS IN THE VENT FRAME.
ROOF VENT (CAP & BASE) - PART # 3311236.XXXa) Center the base over the 6 ½” x 23 ¾” cutout.b) Secure using sixteen #10 screws.c) Place cap on top of base.d) Secure cap to base using four #10 screws.
These screws must be a minimum of 1 ¼” long to provide proper engagement.
e) Apply sealant over all the screws.
UPPER & LOWER SIDE VENT - PART # 3109350.XXX a) Place frame into 13 ¾” x 21 9/16” cutout.b) Secure frame using seven #10 screws through
inside flange of frame. - Alternatively, use seven Z-brackets (see “APPENDIX C”) if the cutout is not framed or the wall is laminate construction. Use #10 screws to secure the frame via the Z-brackets.
c) Install the vent door into the frame using the upper tabs as a guide.
d) Lock the vent door into place by fully seating and twisting the black latches in the bottom corners of the vent door.
1
2
3
4
5
UPPER & LOWER SIDE VENT - PART # 13001 / PART # 13003 a) Place frame into 13 ¾” x 21 9/16” cutout.b) Secure frame using sixteen #10 screws
through inside flange of frame. Install the vent door into the frame using the lower tabs as a guide.
c) Lock the vent door into place by fully seating and twisting the latches in the top corners of the vent door.
UPPER METAL SIDE VENT - PART # 3100451.XXXa) Place vent over 7 ¾“ x 19 ¼” cutout.b) Secure frame using fourteen #10 screws.
- Alternate use of rivets is acceptable.
UPPER METAL SIDE VENT - PART # 8030122.XXXa) Place vent over 10 ¼” x 21” cutout.b) Secure frame using sixteen #10 screws.
- Alternate use of rivets is acceptable.LOWER METAL SIDE VENT - PART # 3102364.XXX / PART # 8030211.XXXa) Place vent over 9 11/16”x 19 ¼” cutout.b) Secure frame using sixteen #10 screws.
- Alternate use of rivets is acceptable.
APPENDIX D - VENT INSTALLATION PROCEDURES
6
- 35 -
APPENDIX D - VENT INSTALLATION PROCEDURESUPPER & LOWER PLASTIC SIDE-BY-SIDE VENT - PART # 3109349.XXXa) Place frame into 13 5/8” x 28 5/8” cutout.b) Secure the frame with five Z-brackets (see
“APPENDIX C”) using #10 screws.c) Install six #10 screws through the front
frame (three each end) to further secure frame.
d) Remove screw cap plugs from the vent frame and install over the six screws in the front frame.
e) Install the vent door into frame using upper tabs as a guide.
f) Lock the vent door into place by fully seating and twisting the black latches in the bottom corners of the vent door.
87 UPPER & LOWER PLASTIC SIDE VENT - PART # 3109492.XXXa) Place frame into 9 11/16” x 19 ¼” cutout.b) Secure the frame with seven Z-brackets
(see APPENDIX C”) using #10 screws.c) Install the vent door into frame using
upper tabs as a guide.d) Lock the vent door into place by fully
seating and twisting the black latches in the bottom corners of the vent door.
- 36 -
RM2351 & RM2354
RM2410 & RM2510
APPENDIX E - REARVIEW EQUIPMENT
Power module cover
Flexible cord
12 V DC Terminal block
Inlet fitting
Manual gas shutoff valve
Burner jet
Screw for protection cover
Protection cover
Drain water hose
Flue baffle Relay
1 heater - RM23512 heaters - RM2354
Inlet fitting
Flexible cord 12 volt DC terminal block
Burner jet
Screw for protection cover Protection cover
- RM2510 only
Flue baffle
Heater
- 37 -
RM2451, RM2454, RM2551 & RM2554
RM2620 & RM2820
Flexible cord
Power modulecover
Relay,3-way only
12 voltTerminal block
Drain water hose
Inlet fitting
Manual gas shutoff valve
Burner jetScrew for protection cover
Heater
Flue baffle
Protection cover
12V DC
APPENDIX E - REARVIEW EQUIPMENT
Protection cover
Flue baffle Power module cover
Flexible cord
Inlet fitting12 volt terminal block
Burner jet
Manual gas shutoff valve
Heater
Thermofuse
Drain water hose 12V DC
- 38 -
APPENDIX E - REARVIEW EQUIPMENT
RM3762 & RM3962
Power module
Flexible cord
12 volt
D+Terminal block
Drain water hose
Inlet fittingManual gasshutoff valve
Burner jet
Screw for protection cover
Protectioncover
Flue baffle
Heater
Thermofuse
385 13 31−01
5
12V DC
HVT
J2 J3 J1 F4 (5A)
F3 (5A) SWITCHED 12V
LAMP TEST LINEAC HTR LINE
AC HTR NEUT
NEUT
DM2652, DM2662, DM2663, DM2852, DM2862 & NDM1062
12V DC
Relay,3-Way only
Power modulecover
Flexible cord
12 volt DCTerminal block
Drain water hose
Inlet fittingManual gasshutoff valve
Burner jet
Screw for protection cover
Protectioncover
Flue baffle
Heater(s)
Thermofuse
Shown without Secondary Burner Housing for illustrative purposes only.
- 39 -
RM1350M & RM1350SLM
385 13 31−01
HVT
J2 J3 J1 F4 (5A)
F3 (5A) SWITCHED 12V
LAMP TEST LINEAC HTR LINE
AC HTR NEUT
NEUT
12V DCD
Power Module
Heaters
Protection Plate
Terminal Block, 12V DCLP - Gas Connection
Flexible Cord
Drain Water Hose
APPENDIX E - REARVIEW EQUIPMENT
RM1350IM, RM1350MIM & RM1350WIM
385 13 31−01
HVT
J2 J3 J1 F4 (5A)
F3 (5A) SWITCHED 12V
LAMP TEST LINEAC HTR LINE
AC HTR NEUT
NEUT
12V DCD
Water HoseIcemaker
Heating Cable
Heaters
Protection Plate
LP - Gas ConnectionWater Valve
Terminal Block, 12V DCAlternator Signal Wire *
ThermostatPower Module
Heating Cable(RM1350WIM Only)
Flexible CordRefrigerator
Flexible CordIcemaker
Water HoseWater in the Door(RM1350WIM Only)
Drain Water Hose
*Valid for refrigerators equipped with the automatic door locking system.
*
- 40 -
APPENDIX E - REARVIEW EQUIPMENT
12V DC12V DC
Heaters
12V DCBurner Control
Protection Cover
Flue Ba�e
Thermofuse
Burner Jet
Inlet Fitting
Thermostat
Manual Gas Shut O� Valve
Flexible Cord Icemaker
Heating Cable
Drain Water Hose
Water Solenoid Valve
Water Hose (Icemaker)
Flexible CordRefrigerator
Power Moduleand Fuses
12 V DC Terminal Block
NDA1402 (WITH ICE MAKER)
385 13 31−01
5
HVT
J2 J3 J1 F4 (5A)
F3 (5A) SWITCHED 12V
LAMP TEST LINEAC HTR LINE
AC HTR NEUT
NEUT
5A
J5 J4 J3 J2
B E H I N D C O V E RC H E C K F U S E
J1
PART No. 385 13 78−01
W A R N I N G !DISCONNECT 120 V AC
BEFORE SERVICING
J6
12V DCD
Water HoseIcemaker
Heating Cable
Heaters
Protection Plate
LP - Gas Connection
Water Valve
Thermostat
Terminal Block, 12V DC
Alternator Signal Wire
Power Module
Heating Cable
Flexible CordRefrigerator
Flexible CordIce Dispenser
Control Unit
Water HoseWater Dispenser Door
Drain Water Hose
RM1350WID
- 41 -
NDA1402 (WITH ICE AND WATER DISPENSERS)
NDA1402 (WITH ICE DISPENSER)
Heaters 12V DC
Protection Cover
Flue Baffle
Thermofuse
Burner Jet
Manual Gas Shut Off Valve
Inlet Fitting
Thermostat
Flexible CordIcemaker, Ice Dispenser
12V DC 12V DC
Water Solenoid Valve
Water Hose (Icemaker)
Heating Cable
Drain Water Hose
12 V DC Terminal Block
Flexible CordRefrigerator
Ice DispenserPower Switch
Power Moduleand Fuses
Burner Control
APPENDIX E - REARVIEW EQUIPMENT
Heaters
12V DC Burner Control
Protection Cover
Flue Baffle
Thermofuse
Burner Jet
Manual Gas Shut Off Valve
Inlet Fitting
Thermostat
Flexible CordIcemaker, Ice Dispenser
12V DC 12V DC
12 V DC Terminal Block
Drain Water Hose
Hose, Icemaker
Hose, Water Dispenser
Heating Cable
Water Solenoid Valve
Flexible Cord Refrigerator
Dispenser Power Switch
Power Module and Fuses
90° Connection, Water Dispenser
- 42 -
APPENDIX E - REARVIEW EQUIPMENTNDM1062 (WITH ICE MAKER)
12V DC
Relay
Power Module Cover
Flexible Cord
Flexible Cord(Icemaker)
Drain Water Hose
ThermostatInlet Fitting
Manual Gas Shutoff Valve Burner Jet
Protection Cover
Flue Baffle
Thermofuse
Heater
12V DCTerminal Block
Shown without Secondary Burner Housing for illustrative purposes only.
- 43 -
RM2351, RM2451 & RM2551
RM2354, RM2454 & RM2554
APPENDIX F - WIRING DIAGRAMS
- 44 -
APPENDIX F - WIRING DIAGRAMSRM2410
RM2510
F
21
6
2
G4B C
2
5
11A
C
E
2A
NL
B
D
D
312
NL
12
34
56
AB
CD
EF
G
A
F
G
293 00 92 2
100/120 VOLTS AC
12 VOLTS DC100/120 VOLTS AC 12 VOLTS DC
WHITE
BLACK
GREEN
GREEN/YELLOW
RED
GREY
SWITCH
THERMOSTAT
JUNCTION BLOCK
HEATER
TERMINAL BLOCK
REIGNITER
PILOT LAMP
5
385 13 76
3
1
2
D C
11
A
2
120 VOLTS AC
LN
CB
NL
AB
D
120 VOLTS AC
WHITE
BLACK
GREEN
1
2
3
HEATERD
C JUNCTION BLOCK
THERMOSTATB
SWITCHA
1
2
3
4L
5N 5a
4a
3a
2a
1a
5N 5a
4a4L
3 3a
2a2
1 1a
- 45 -
APPENDIX F - WIRING DIAGRAMSRM2620 & RM2820
DM2652, DM2662, DM2852 & DM2862 (NO FAN) WITH & WITHOUT ICE MAKER385 14 82
12V DC
J
AB
CD
EF
G
CIRCUIT BOARD DISPLAYFUSE 5A
SWITCH LAMP
LK
LAMP
MN
RETAINER
CHASSIS GROUND
SOLENOID VALVETHERMISTOR
CIRCUIT BOARD POWER S
HEATING CABLE
PROTECTIVE EARTH
T
H
FUSE 3A
ELECTRODE
TERMINAL BLOCK
YELLOW
98
WHITEGREYBLUE
REDBROWNBLACK1
23
45
67
J HEATER 120V ACGREENGREEN/YELLOW
N
GROUND+12V
L
1 2 3 4 1 2 3 4 5 6 1 2
DISPLAYBOARD
3 AJ 4
J 5
J 2
J 6
J 7
J 8
M
P3
J 1 0
P1 P2
T
5 A
D
J2
J10
P 1 − 1P 1 − 4
P 3 − 4P 3 − 3
P 3 − 1A
CB
J4
J5
J8
J7
J6
P 3 − 2
T
P 1 − 5P 1 − 2
P 1 − 6P 1 − 3
M P 2 − 1P 2 − 29
9
GREENORANGE
BLUERED
BROWNBLACK
L N
19
5L
1
E
6 O
P S
1
8
N
K
3
UTEST POINT
GH
N
E
THERMAL FUSE
P
3
49
J
11
F
3
F
O
THERMOFUSE
U
U
GH
1
K
385 14 81
12V DC
J
AB
CD
EF
G
CIRCUIT BOARD DISPLAYFUSE 5A
SWITCH LAMP
LK
LAMP
MN
RETAINER
CHASSIS GROUND
SOLENOID VALVETHERMISTOR
CIRCUIT BOARD POWERS
HEATING CABLE
PROTECTIVE EARTH
T
H
FUSE 3A
ELECTRODE
TERMINAL BLOCK
YELLOW
98
WHITEGREYBLUE
REDBROWNBLACK1
23
45
67
J HEATER 120V ACGREENGREEN/YELLOW
N
GROUND+12V
L
1 2 3 4 1 2 3 4 5 6 1 2
DISPLAYBOARD
3 AJ 4
J 5
J 2
J 6
J 7
J 8
M
P3
J 1 0
P1 P2
T
5 A
D
J2
J10
P 1 − 1P 1 − 4
P 3 − 4P 3 − 3
P 3 − 1A
CB
J4
J5
J8
J7
J6
P 3 − 2
T
P 1 − 5P 1 − 2
P 1 − 6P 1 − 3
M P 2 − 1P 2 − 29
9
GREENORANGE
BLUERED
BROWNBLACK
L N
19
5L
1
E
6 O
P S
1
8
TEST POINT
N
E
P
3
49
J
11
F
3
O
THERMOFUSE
K
3
GH
1
N
GH
F
K
- 46 -
APPENDIX F - WIRING DIAGRAMSDM2652, DM2662, DM2852 & DM2862 (ONE FAN) WITH AND WITHOUT ICE MAKER
385 14 84
12V DC
J
AB
CD
EF
G
CIRCUIT BOARD DISPLAYFUSE 5A
SWITCH LAMP
LK
LAMP
MN
RETAINER
TEST POINT
SOLENOID VALVETHERMISTOR
CIRCUIT BOARD POWERT
HEATING CABLE
CHASSIS GROUND
X
H
FUSE 3A
ELECTRODE
TERMINAL BLOCK YELLOW
98
WHITEGREYBLUE
REDBROWNBLACK1
23
45
67
J HEATER 120V AC
GREENGREEN/YELLOW
N
GROUND+12V
L
1 2 3 4 1 2 3 4 5 6 1 2
DISPLAYBOARD
3 AJ 4
J 5
J 2
J 6
J 7
J 8
M
P3
J 1 0
P1 P2
T
5 A
D
J2
J10
P 1 − 1P 1 − 4
P 3 − 4P 3 − 3
P 3 − 1A
CB
J4
J5
J8
J7
J6
P 3 − 2
T
P 1 − 5P 1 − 2
P 1 − 6P 1 − 3
M P 2 − 1P 2 − 29
9
GREENORANGE
BLUERED
BROWNBLACK
L N
19
5L
1
E
6 O
P S
1
8
3
VFUSE 3A
N
E
FAN
S
3
49
J
11
F
3
F
O
THERMOFUSE
U
33
1
U
U THERMOFUSE
V
PROTECTIVE EARTHP
V
X
Y THERMAL FUSE
3 A
Y
Y
N
K
GH
GH
1
K
DM2852 & DM2862 (ONE OR TWO FANS) WITH AND WITHOUT ICE MAKER
- 47 -
DM2663 (NO FAN) WITHOUT ICE MAKER385 14 83
12V DC
AB
CD
EF
G
CIRCUIT BOARD DISPLAYFUSE 5A
SWITCH LAMP
LK
HEATER 12V DC
LAMP
MN
RETAINERP
CHASSIS GROUND
SOLENOID VALVETHERMISTOR
CIRCUIT BOARD POWERU
HEATING CABLE
PROTECTIVE EARTH
W
H
FUSE 3A
ELECTRODE
TERMINAL BLOCK
YELLOW
98
WHITEGREYBLUE
REDBROWNBLACK1
23
45
67
JHEATER 120V AC
GREENGREEN/YELLOW
1 2 3 4 1 2 3 4 5 6 1 2
DISPLAYBOARD
3 AJ 4
J 5
J 2
J 6
J 7
J 8
N
P3
J 1 0
P1 P2
X
5 A
D
J2
P 1 − 1P 1 − 4
P 3 − 4P 3 − 3
P 3 − 1A
CB
J4
J5
P 3 − 2
X
P 1 − 5P 1 − 2
P 1 − 6P 1 − 3
N P 2 − 1P 2 − 29
9
GREENORANGE
BLUERED
BROWNBLACK
L N
K
19
5M
1
E
6 R
S U
49
1
3
XFUSE 30A
ORELAY
P
8 5 8 7
1
77
J
O
E
8 5 8 7
P
YTEST POINT
3
3
W
THERMAL FUSE
S
31
J10
J7
J6
J8
F
W
+12V
L
F
3K
N
J
GROUND
8 6 3 0
8 6 3 0
8
R
THERMOFUSE
3
Y
Y
O
L
GH
GH
L
1
1
RM3762 & RM3962 (NO FAN) WITHOUT ICE MAKER3 8 5 1 4 9 5
+
K
L N
1
9
5
G
H
6P
12V DC D+
1
P1−1P1−2P1−3
CP2−1P2−29
9
B
BROWNBLACKRED
J
O
1
1
10
3
CONTROL BOARDAB
CD
EF SOLENOID VALVE
KJ
THERMAL FUSE
LM
N
SR
BURNER HOUSING
HEATING CABLET
RETAINER
SWITCH LAMP
PROTECTIVE EARTH
G
FUSE 5A GLASS
HEATER 120V AC
98
W H I T EG R E YBLUE
REDBROWNBLACK1
23
45
67
HTHERMO FUSE
GREENGREEN/YELLOW
YELLOW
O CHASSIS GROUNDP TERMINAL BLOCK
LAMP
13
A
T
S R8
10
1
1
10 L I G H T B L U E
P2
E
D
P6
P7
P4
P3
P1
F 3
P5
J 2 J3 J1
CIRCUIT BOARD POWER
34
7
7
F
9
CIRCUIT BOARD DISPLAY
FUSE 5A MINI AUTOTHERMISTOR
ELECTRODE
L
M
9
N
P2
E
D
P 6
P7
P4
P3P1
F3
P 5
J2
J3
J1
K
C
FN
GROUND
T
L
DISPLAY
BUTTONS
H
G
J
S
1
APPENDIX F - WIRING DIAGRAMS
- 48 -
NDM1062 (STAINLESS STEEL DOORS)
U
3
12V DC
H
AB
CD
EF
G
CIRCUIT BOARD DISPLAYFUSE 5A
SWITCH LAMP
LK
HEATER 120V AC
LAMP
MN
THERMOFUSE
PROTECTIVE EARTHR
TEST POINT
FANS
CIRCUIT BOARD POWERS
TERMINAL BLOCK
CHASSIS GROUNDT
H
FUSE 3A
ELECTRODE
THERMISTOR
J HEATING CABLE
N
GROUND+12V
L
1 2 3 4 1 2 3 4 5 6 1 2
DISPLAYBOARD
3 AJ4
J5
J2
J6
J7
J8
L
P3
J10
P1 P2
T
5 A
D
J CLC
J2
J10
P 1 − 1P 1 − 4
P 3 − 4P 3 − 3
P 3 − 1
A
CB
J5
J8
J7
J6
P 3 − 2
T
P 1 − 5P 1 − 2
P 1 − 6P 1 − 3
L P 2 − 1P 2 − 29
9
GREENORANGE
BLUERED
BROWNBLACK
3
L N
H
19
5K
1
O
6 P
R S
49
GND
LAC
+12V
F G
18
33
1
8
LAC
+12V
GND
CLC
G
O
J
E
F
U THERMOFUSE
E
8
J4 M
33
N
11
11
OP
SOLENOID VALVERETAINER
M
N
31 1
3 A
V
FUSE 3AV
U
GREEN/YELLOWGREEN
76
54
32
1 BLACKBROWNRED
BLUEGREYWHITE
89
YELLOW
THERMAL FUSEY
Y
Y
385 14 04
APPENDIX F - WIRING DIAGRAMSRM3762 & RM3962 (ONE OR TWO FANS) WITH AND WITHOUT ICE MAKER
- 49 -
NDM1062 (STAINLESS STEEL DOORS & ICE MAKER)385 14 44
U
3
12V DC
H
AB
CD
EF
G
CIRCUIT BOARD DISPLAYFUSE 5A
SWITCH LAMP
LK
HEATER 120V AC
LAMP
MN
THERMOFUSE
PROTECTIVE EARTHV
ICEMAKER
FANS
CIRCUIT BOARD POWERY
TERMINAL BLOCK
CHASSIS GROUNDAA
H
FUSE 3A
ELECTRODE
THERMISTOR
YELLOW
98
WHITEGREYBLUE
REDBROWNBLACK1
23
45
67
J HEATING CABLE
GREENGREEN/YELLOW
N
GROUND+12V
L
1 2 3 4 1 2 3 4 5 6 1 2
DISPLAYBOARD
3 AJ4
J5
J2
J6
J7
J8
L
P3
J10
P1 P2
T
5 A
D
J CLC
J2
J10
P 1 − 1P 1 − 4
P 3 − 4P 3 − 3
P 3 − 1
A
CB
J5
J8
J7
J6
P 3 − 2
T
P 1 − 5P 1 − 2
P 1 − 6P 1 − 3
L P 2 − 1P 2 − 29
9
GREENORANGE
BLUERED
BROWNBLACK
3
L N
H
19
5K
1
O
6 P
R S
49
GND
LAC
+12V
F
G
18
33
1
8
LAC
+12V
GND
CLC
G
O
J
E
FAB WATER VALVE
E
8
J4 M
33
N
11
11
OP
SOLENOID VALVERETAINER
M
N
31 1
V
TERMINAL BLOCKAC
Y
AD RELAY
8 5
8 7
8 6
3 0
AG
°
AF
AE
C
AD
3
3
3
11
1
M B 4
AB
AA
62
19
96
3 A
8 5
8 7
8 6
3 0
AG
°
AF
AE
C
AD
M B 4
AB
AA
NL GROUND
U
Y
L N120 V AC
AC
15
9
6
RS
PROTECTIVE EARTHCHASSIS GROUND
TU
TEST POINTTHERMOFUSE
HEATING CABLEAEAF THERMOSTAT
FUSE 4AAG
APPENDIX F - WIRING DIAGRAMS
- 50 -
APPENDIX F - WIRING DIAGRAMSNDM1062 (DOOR INSERT PANELS)
NDM1062 (DOOR INSERT PANELS & ICE MAKER)
W
3
12V DC
H
AB
CD
EF
G
CIRCUIT BOARD DISPLAYFUSE 5A
SWITCH LAMP
LK
HEATER 120V AC
LAMP
MN
THERMOFUSEFANS
CIRCUIT BOARD POWER
TERMINAL BLOCK
H
FUSE 3A
ELECTRODE
THERMISTOR YELLOW
98
WHITEGREYBLUE
REDBROWNBLACK1
23
45
67
J HEATING CABLE
GREENGREEN/YELLOW
N
GROUND+12V
L
1 2 3 4 1 2 3 4 5 6 1 2
DISPLAYBOARD
3 AJ4
J5
J2
J6
J7
J8
L
P3
J10
P1 P2
Z
5 A
D
J2
P 1 − 1P 1 − 4
P 3 − 4P 3 − 3
P 3 − 1
A
CB
J5
J8
J7
J6
P 3 − 2
Z
P 1 − 5P 1 − 2
P 1 − 6P 1 − 3
L P 2 − 1P 2 − 29
9
GREENORANGE
BLUERED
BROWNBLACK
3
L N
H
19
5K
1
O
6 P
S X
49
F
G
8
O
E
J
T
3
U
3
8
O SOLENOID VALVE
311
J
U
FG
T
J10
E
8
J4
33 31 1
M N
1
11
1
M
N
P RETAINER
3 A
Y
THERMAL FUSER
S PROTECTIVE EARTH
TEST POINTZFUSE 3AYCHASSIS GROUNDX
WSWITCH L.A.CUTHERMOFUSE
T SWITCH
R
W
R
385 14 05
385 14 52
H
AB
CD
EF
G
CIRCUIT BOARD DISPLAYFUSE 5A
SWITCH LAMP
LK
HEATER 120V AC
LAMP
M
S
THERMOFUSE
WATER VALVEAB
RELAY
PROTECTIVE EARTH
CIRCUIT BOARD POWER
AC
TERMINAL BLOCK
TERMINAL BLOCKAD
H
FUSE 3A
ELECTRODE
THERMISTOR
YELLOW
98
WHITEGREYBLUE
REDBROWNBLACK1
23
45
67
J HEATING CABLE
GREENGREEN/YELLOW
N
GROUND+12V
L
1 2 3 4 1 2 3 4 5 6 1 2
DISPLAYBOARD
3 AJ4
J5
J2
J6
J7
J8
L
P3
J10
P1 P2
Z
5 A
O
E
J
T
U3 8
AE HEATING CABLE
T SWITCH
311
U
FG
T
AF THERMOSTAT
W
M
N
U SWITCH L.A.CW THERMOFUSE
3 A
AG FUSE 4A
R
AA ICEMAKER
W
3
12V DC
D
J2
J10
P 1 − 1P 1 − 4
P 3 − 4P 3 − 3
P 3 − 1
A
CB
J5
J8
J7
J6
P 3 − 2
Z
P 1 − 5P 1 − 2
P 1 − 6P 1 − 3
L P 2 − 1P 2 − 29
9
GREENORANGE
BLUERED
BROWNBLACK
3
L N
H
19
5K
1
O
6 P
S X
49
F
G
8
E
8
J4 M
33
N
11
11
31 1
Y
R
8 5
8 7
8 6
3 0
AG
°
AF
AE
C
AD
3
3
3
11
1
M B 4
AB
AA
L N120 V AC
AC
15
9
62
19
96
6
3
8 5
8 7
8 6
3 0
AG
°
AF
AE
C
AD
J
M B 4
AB
AA
NL GROUND
N FANSO SOLENOID VALVE
P RETAINERR THERMAL FUSE
ZFUSE 3AYTEST POINT
X CHASSIS GROUND
- 51 -
APPENDIX F - WIRING DIAGRAMSRM1350M (MANUAL DOOR LOCK & DOOR INSERT PANELS OR STEEL DOORS)
RM1350MIM (MANUAL DOOR LOCK, ICE MAKER & DOOR INSERT PANELS)
RM1350SLM (MANUAL DOOR LOCK & DOOR INSERT PANELS OR STEEL DOORS)3851491 01
+ L N
19
5
12V DC
CONTROL BOARDAB
CD
EF
HEATING CABLETHERMISTOR
KJ
LM
N LAMPTHERMOSTATDOOR CONTACT
BURNER HOUSING
G
CIRCUIT BOARD DISPLAY
SOLENOID VALVE
HEATING CABLE GIRDER
H ELECTRODE
O HEATING CABLEP SWITCH LAMP
3 8 5 1 4 9 1 0 0
RELAY
8 5
8 7
8 6
3 0
°
D+
S
UV
X
HEATER 120V AC
THERMOSTATCHASSIS GROUNDY
RETAINER
R THERMO FUSES TERMINAL BLOCK
98
W H I T EG R E YBLUE
REDBROWNBLACK1
23
45
67
GREENGREEN/YELLOW
YELLOW
10 L I G H T G R E E N
120 VAC
C
1
X
Y
1
4A
D
U
Z
P
N1
1 10
103 3
3
13
1
1
1
3
3
3
3
3
O
Y
Z PROTECTIVE EARTH
1
WHITEBLACKBROWNGREEN
L N
19
5
120 VAC
Z
9
ICEMAKER
I N OPERATION THE ICEMAKERWILL ADD 1.4 A TO THETOTAL REFRIGERATOR DRAW
1010
3 1
K
L
WATER VALVE
V
3
FAN
FAN
3
131
MC°
P1−1P1−2P1−3
B
BROWNBLACK
REDA
P2−1P2−29
9C
P2
G
F
P6
P7
P4
P3
P1
F 3
P5
J 2 J3 J1
7
1
H
R4
J
E
7
9
3
CIRCUIT BOARD POWER
1
9
3
FUSE 5A MINI AUTO FUSEFUSE 5A GLASS
OPTIONAL ICE MAKER INSTALLATION
A
- 52 -
APPENDIX F - WIRING DIAGRAMSRM1350IM (AUTOMATIC DOOR LOCK, ICE MAKER & STEEL DOORS)
RM1350WIM (AUTOMATIC DOOR LOCK, ICE MAKER, WATER DISPENSER & DOOR INSERT PANELS OR STEEL DOORS)
+
L N
19
5
12V DC
CONTROL BOARDAB
CD
EF
HEATING CABLETHERMISTOR
KJ
LM
N LAMPTHERMOSTATDOOR CONTACT
BURNER HOUSING
G
CIRCUIT BOARD DISPLAY
SOLENOID VALVE
HEATING CABLE GIRDER
H ELECTRODE
O HEATING CABLEP SWITCH LAMP
3 8 5 1 4 9 2
RELAY
8 5
8 7
8 6
3 0
FAN
°
D+
S
TU
VX
HEATER 120V ACDOOR IGNITION LOCK
THERMOSTATCHASSIS GROUNDY
RETAINER
R THERMO FUSES TERMINAL BLOCK
98
W H I T EG R E YBLUE
REDBROWNBLACK1
23
45
67
GREENGREEN/YELLOW
YELLOW
10 L I G H T G R E E N
120 VAC
C
1
X
Y
1
°C M
4A
D
1 2 3
T
U
Z
P
N
13
3
1
1 10
103 3
3
13
1
1
11
33
3
3
9
3
3
O
Y
Z PROTECTIVE EARTH
1
WHITEBLACKBROWNGREEN
L N
19
5
120 VAC
Z
9
ICEMAKER
I N OPERATION THE ICEMAKERWILL ADD 1.4 A TO THETOTAL REFRIGERATOR DRAW
1010
3 1
K
L
WATER VALVE
V
1
FAN
3
P1−1P1−2P1−3
B
BROWNBLACK
REDA
P2−1P2−29
9C
P2
G
F
P6
P7
P4
P3
P1
F 3
P5
J 2 J3 J1
7
H
R4
J
E
7
9
3
CIRCUIT BOARD POWER
1
3
1
FUSE 5A GLASSFUSE 5A MINI AUTO FUSE
9
+
L N
19
5
12V DC
CONTROL BOARDAB
CD
EF
HEATING CABLETHERMISTOR
FUSE 5A MINI AUTO FUSE
KJ
FUSE 5A GLASS
LM
N LAMPTHERMOSTATDOOR CONTACT
RETAINER
G
CIRCUIT BOARD DISPLAY
SOLENOID VALVE
HEATING CABLE GIRDER
H ELECTRODE
O HEATING CABLEP SWITCH LAMP
3 8 5 1 4 9 3
RELAY
8 5
8 7
8 6
3 0
°
D+
S
WHITEBLACKBROWNGREEN
TU
VX
HEATER 120V ACDOOR IGNITION LOCK
THERMOSTATCHASSIS GROUNDY
WATER DISPENSER
R THERMO FUSES TERMINAL BLOCK
98
W H I T EG R E YBLUE
REDBROWNBLACK1
23
45
67
GREENGREEN/YELLOW
YELLOW
10 L I G H T G R E E N
WATER VALVE W112VDC
W2120VAC
93
120 VAC
L N
19
5
120 VAC
Z
1 2 3
V
C
1
X
Y
1
°C M
4A
D
1 2 3
T
U
Z
P
N
13
3
1
1 10
103 3
3
13
1
1
11
33
33 1
3
9
3
3
O
9
ICEMAKER
Y
Z PROTECTIVE EARTH
1
IN OPERATION THE ICEMAKERWILL ADD 1.4 A TO THETOTAL REFRIGERATOR DRAW
1010
K
L
3 1
J
FAN
13
FAN
1
33
P1−1P1−2P1−3
B
BROWNBLACK
REDA
P2−1P2−29
9C
P2
G
F
P6
P7
P4
P3
P1
F 3
P5
J 2 J3 J1
CIRCUIT BOARD POWER
7
H
R4
J
E
7
9
3
11
9
3
- 53 -
APPENDIX F - WIRING DIAGRAMSRM1350WID (AUTOMATIC DOOR LOCK, ICE MAKER, WATER AND ICE DISPENSERS & DOOR
INSERT PANELS OR STEEL DOORS)
+
L N
19
5
12V DC
CONTROL BOARDB
CD
EF
G
HEATING CABLETHERMISTOR
KJ
LM
N LAMPTHERMOSTATDOOR CONTACT
RETAINER
H
CIRCUIT BOARD DISPLAY
SOLENOID VALVE
HEATING CABLE GIRDER
IELECTRODE
O HEATING CABLEP SWITCH LAMP
3 8 5 1 4 9 4
RELAY
8 5
8 7
8 6
3 0
°
D+
S
TU
VX
HEATER 120V ACDOOR IGNITION LOCK
THERMOSTATCHASSIS GROUNDY
QTHERMO FUSERTERMINAL BLOCK
98
W H I T EG R E YBLUE
REDBROWNBLACK1
23
45
67
GREEN
GREEN/YELLOW
YELLOW10 L I G H T G R E E N
WATER VALVE W112VDC
W2120VAC
93
120 VAC
L N
19
5
120 VAC
Z
V
C
1
X
Y
1
°C M
4A
D
1 2 3
T
U
Z
P
N
13
3
1
1 10
103 3
3
13
1
1
11
33
3
3
3
9
3
3
O9
ICEMAKER
Y
Z PROTECTIVE EARTH
1
IN OPERATION THE ICEMAKERWILL ADD 1.4 A TO THETOTAL REFRIGERATOR DRAW
1010
K
L
3 1
J
FAN
13
FAN
1
33
J 8 − 1J 8 − 3
J 8 − 4J 8 − 2
5A
J4
J3
J6
J5
J2
J1
C ONTROL MODULE WATER & ICE
31
J7−2
J7−1
12
Q
AUGER
S
WATER & ICE DISPENSER
I
U3U4
A
HEATING CABLE DOOR
9
4
5
U1−1U1−2
9
9
9
12
5
P1−1P1−2P1−3
B
BROWNBLACK
REDA
P2−1P2−29
9C
P2
G
F
P6
P7
P4
P3
P1
F 3
P5
J 2 J3 J1
7
H
R4
J
E
7
9
3
CIRCUIT BOARD POWER
11
FUSE 5A MINI AUTO FUSEFUSE 5A GLASS
93
- 54 -
APPENDIX F - WIRING DIAGRAMSNDA1402*
FUSESFuses (from left to right) protect the following components.
Fuse Type of component3A A, B, C, E, G, H, P, R
7.5A S, T
3A W*
7.5A X
5A Z
* Optional ice maker heat-kit
6
7
8
9
105
4
3
2
1
BLACK
YELLOW
RED
BLACK
REDBLACK
RED
BLACK
WHITE
RED
BROWN
GREEN
BLACK
RED
2
4
65
3
1
12
34 4
32
1
BLUE
YELLOWGREY
2
43
1
6
5
41
2
3
RED
WHITE
REDBLACK
YELLOW
BLACK
J
K
L
M
F
D
E
H
G
1
34
2GREY
WHITEYELLOW
BLUE
R
DISPLAY
1 2
WHITE
YELLOW
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
J11
TESTPORT
3A
7.5A
5A
7.5A
3A
Z
+ −12V DC
BLACK
RED
WHITE
WHITE
BLACK
RED
BLACK
BLACK
LN
Y
AB
CD
EF
G
SWITCH FREEZER12V DC BURNER CONTROL
LAMP FRIDGE
LK
FAN FRIDGE
SWITCH FRIDGE
M
PO
SOLENOID VALVEQ
FAN FREEZER
ELECTRODE
THERMISTOR FREEZER FLANGE
CIRCUIT BOARD POWER
R
THERMISTOR FRIDGE FLANGE
THERMOSTAT
H
CIRCUIT BOARD DISPLAY
LAMP FREEZER
THERMISTOR FREEZER AIR
J THERMISTOR FRIDGE AIR
HEATING ELEMENT DRAIN TRAYT HEATING ELEMENT FRIDGE
S
UTHERMOFUSEVTERMINAL BLOCK
HEATING CABLE FRONT FRAMEX HEATING ELEMENT FREEZER
W
YHEATER 120V ACZPROTECTIVE EARTH
S T
N
N
X
W
U
BLAC
K
RED
V
B
GREY
B LACK
WHITE
OP
C
A
P3 P2 BLUE
P5 BLUE
BLACK
O RANGE
385 13 24
FAN
°CQ
FAN
RED
RED
RED
RED
BLACK
BLACK
N CHASSIS GROUND
3A
2
3A inline fuse for the power vent fans
*NDA1402 has two wiring diagrams:
• Models with ice maker 3851324 (2) + 3850699 (2)
• Models with ice dispenser 3851324 (2) + 3850897 (3)
• Models with ice and water dispensers 3851324 (2) + 3851112
NDA1402 (WITH ICE MAKER)3851324 (2) + 3850699 (2)
- 55 -
APPENDIX F - WIRING DIAGRAMSNDA1402 (WITH ICE DISPENSER)
3851324 (2) + 3850897(3)
NDA1402 (WITH ICE AND WATER DISPENSERS)3851324 (2) + 3851112
- 56 -
NOTES