7 0 e s connection ~700 safeend ~ 8450 regulations 7 ... · gln fsgln ö gln 1:20 2015-02-23...
TRANSCRIPT
![Page 1: 7 0 E S CONNECTION ~700 SafeEnd ~ 8450 REGULATIONS 7 ... · gln fsgln ö gln 1:20 2015-02-23 safeend 07 birsta safeend p4 profile-a left/right 507,9 kg assembly drawing in review](https://reader033.vdocument.in/reader033/viewer/2022050404/5f815ccbe4b227792461e115/html5/thumbnails/1.jpg)
A ( 1 : 5 )
B ( 1 : 5 )
C ( 1 : 5 )
D ( 1 : 5 ) LEFT MOUNTEDE ( 1 : 5 ) RIGHT MOUNTED
8920082 / RSK75110.5BL PESafeEnd SIDE CAP211
1123160000M6M M16HDGHEX NUT M16610
112617340017x34HDGWASHER ROUND129
1120161500M16x150HDGBOLT M16 68
8920026 HDGCONNECTION REVERSIBLE17
112613240213x24x4HDGWASHER ROUND TBRUB16.3
1120120300M12x30HDGSCREW M12 16.2
8920505 HDG CONNECTOR PLATE16.1
8920301A (ASSAMBLED) HDGC-POST 140x40 16
112320000M6M M20HDGHEX NUT M2025
112621360021x36HDGWASHER ROUND104
1120120080M20x80HDGCARRIAGE BOLT M2023
8920531 / 89205302000 / 1500HDGBirsta "Nail" ANCHOR TUBE12
89200080 Birsta SafeEnd11
A
BC
D
E
Cop
yright
Birst
aver
ken
AB
SafeEnd 07Rev.Drawing no.
Date
ScaleCopiedDesign. Drawn Stand.Checked Appr. Replaces Replaced by
www.birsta.eu a SAFEROAD company
GLNGLN FSö GLN 1:20
2015-02-23
SafeEnd 07
Birsta SafeEnd P4PROFILE-A LEFT/RIGHT
507,9 kg
ASSEMBLY DRAWING In Review
652`20
8450SafeEnd ~ CONNECTION ~700
6800`20
250
1
2
33
345
OPTION: 8920081
PLASTIC COVER MOUNTED ON SITE WITH 6x
MAURUTEX SCREW A2 M5,5x20.
CAN BE PROVIDED WITH VARIOUS TYPE OF
REFLEX, POINTING TO RIGHT, LEFT OR
MIDDLE EX.
6
8 9 10
CONNECTING SYSTEM
SINGLE SIDED PROFILE-A (W-PROFILE)
HEIGHT 700 / 750 MM
HDG. IN PART LIST STANDS FOR HOT DIP GALVANIZING
ACCORDING TO EN ISO 1461
BOLT, SCREWS & NUTS ACC. TO EN ISO 10648
6.16.26.3
HEIGHT ACC. TO CONNECTING SYSTEM
8700`50
1900`20
REGULATIONS
ENV 1317-4
EN ISO 1461 (HOT DIP GAVANIZING)
ADDITIONAL INFORMATION
PERFOMANCE LEVEL: P4
IMPACT SEVERITY LEVEL: B
LATERAL DISPLACEMENT CLASS: D1.1
REDIRECTION ZONE: Z1
7
~ 295
33
11
![Page 2: 7 0 E S CONNECTION ~700 SafeEnd ~ 8450 REGULATIONS 7 ... · gln fsgln ö gln 1:20 2015-02-23 safeend 07 birsta safeend p4 profile-a left/right 507,9 kg assembly drawing in review](https://reader033.vdocument.in/reader033/viewer/2022050404/5f815ccbe4b227792461e115/html5/thumbnails/2.jpg)
A ( 1 : 5 )
B ( 1 : 5 )
C ( 1 : 5 )
D ( 1 : 5 )
8920082 / RSK75110.5BL PESafeEnd SIDE CAP211
1123160000M6M M16HDGHEX NUT M16610
112617340017x34HDGWASHER ROUND129
1120161500M16x150HDGBOLT M16 68
8920029 HDGCONNECTION DOUBLE17
112613240213x24x4HDGWASHER ROUND TBRUB16.3
1120120300M12x30HDGSCREW M12 16.2
8920505 HDG CONNECTOR PLATE16.1
8920301A (ASSAMBLED) HDGC-POST 140x40 16
112320000M6M M20HDGHEX NUT M2025
112621360021x36HDGWASHER ROUND104
1120120080M20x80HDGCARRIAGE BOLT M2023
8920531 / 89205302000 / 1500HDGBirsta "Nail" ANCHOR TUBE12
89200080 Birsta SafeEnd11
A
BC
D
Cop
yright
Birst
aver
ken
AB
SafeEnd 08Rev.Drawing no.
Date
ScaleCopiedDesign. Drawn Stand.Checked Appr. Replaces Replaced by
www.birsta.eu a SAFEROAD company
GLNGLN LGN LGN 1:20
2015-02-25
SafeEnd 08
Birsta SafeEnd P4PROFILE-A DOUBLE
517,4 kg
ASSEMBLY DRAWING In Review
652`20
8450SafeEnd ~ CONNECTION ~700
6800`20
250
1
2
345
OPTION: 8920081
PLASTIC COVER MOUNTED ON SITE WITH 6x
MAURUTEX SCREW A2 M5,5x20.
CAN BE PROVIDED WITH VARIOUS TYPE OF
REFLEX, POINTING TO RIGHT, LEFT OR
MIDDLE EX.
6
8 9 10
CONNECTING SYSTEM
DOUBLE PROFILE-A (W-PROFILE)
HEIGHT 700 / 750 MM
HDG. IN PART LIST STANDS FOR HOT DIP GALVANIZING
ACCORDING TO EN ISO 1461
BOLT, SCREWS & NUTS ACC. TO EN ISO 10648
6.16.26.3
HEIGHT ACC. TO CONNECTING SYSTEM
8700`50
1900`20
REGULATIONS
ENV 1317-4
EN ISO 1461 (HOT DIP GAVANIZING)
ADDITIONAL INFORMATION
PERFOMANCE LEVEL: P4
IMPACT SEVERITY LEVEL: B
LATERAL DISPLACEMENT CLASS: D1.1
REDIRECTION ZONE: Z1
7
~ 29511
L=20
00 IN G
RAVEL
L=1500
IN A
SPHALT
![Page 3: 7 0 E S CONNECTION ~700 SafeEnd ~ 8450 REGULATIONS 7 ... · gln fsgln ö gln 1:20 2015-02-23 safeend 07 birsta safeend p4 profile-a left/right 507,9 kg assembly drawing in review](https://reader033.vdocument.in/reader033/viewer/2022050404/5f815ccbe4b227792461e115/html5/thumbnails/3.jpg)
A ( 1 : 5 )
B ( 1 : 5 )
C ( 1 : 5 )
D ( 1 : 5 ) LEFT MOUNTEDE ( 1 : 5 ) RIGHT MOUNTED
8920082 / RSK75110.5BL PESafeEnd SIDE CAP211
1123160000M6M M16HDGHEX NUT M16610
112617340017x34HDGWASHER ROUND129
1120161500M16x150HDGBOLT M16 68
8920031 HDGCONNECTION REVERSIBLE17
112613240213x24x4HDGWASHER ROUND TBRUB16.3
1120120300M12x30HDGSCREW M12 16.2
8920505 HDG CONNECTOR PLATE16.1
8920301A (ASSAMBLED) HDGC-POST 140x40 16
112320000M6M M20HDGHEX NUT M2025
112621360021x36HDGWASHER ROUND104
1120120080M20x80HDGCARRIAGE BOLT M2023
8920531 / 89205302000 / 1500HDGBirsta "Nail" ANCHOR TUBE12
89200080 Birsta SafeEnd11
A
BC
D
E
Cop
yright
Birst
aver
ken
AB
SafeEnd 09Rev.Drawing no.
Date
ScaleCopiedDesign. Drawn Stand.Checked Appr. Replaces Replaced by
www.birsta.eu a SAFEROAD company
GLNGLN FSö GLN
2015-02-26
SafeEnd 09
Birsta SafeEnd P4PROFILE-B LEFT/RIGHT
508,1 kg
ASSEMBLY DRAWING In Review
652`20
8450SafeEnd ~ CONNECTION ~700
6800`20
250
1
2
28
345
OPTION: 8920081
PLASTIC COVER MOUNTED ON SITE WITH 6x
MAURUTEX SCREW A2 M5,5x20.
CAN BE PROVIDED WITH VARIOUS TYPE OF
REFLEX, POINTING TO RIGHT, LEFT OR
MIDDLE EX.
6
8 9 10
CONNECTING SYSTEM
SINGLE SIDED PROFILE-B
HEIGHT 700 / 750 MM
HDG. IN PART LIST STANDS FOR HOT DIP GALVANIZING
ACCORDING TO EN ISO 1461
BOLT, SCREWS & NUTS ACC. TO EN ISO 10648
6.16.26.3
HEIGHT ACC. TO CONNECTING SYSTEM
8700`50
1900`20
REGULATIONS
ENV 1317-4
EN ISO 1461 (HOT DIP GAVANIZING)
ADDITIONAL INFORMATION
PERFOMANCE LEVEL: P4
IMPACT SEVERITY LEVEL: B
LATERAL DISPLACEMENT CLASS: D1.1
REDIRECTION ZONE: Z1
7
~ 29511
L=20
00 IN G
RAVEL
L=1500
IN A
SPHALT
30
![Page 4: 7 0 E S CONNECTION ~700 SafeEnd ~ 8450 REGULATIONS 7 ... · gln fsgln ö gln 1:20 2015-02-23 safeend 07 birsta safeend p4 profile-a left/right 507,9 kg assembly drawing in review](https://reader033.vdocument.in/reader033/viewer/2022050404/5f815ccbe4b227792461e115/html5/thumbnails/4.jpg)
A ( 1 : 5 )
B ( 1 : 5 )
C ( 1 : 5 )
D ( 1 : 5 )
8920082 / RSK75110.5BL PESafeEnd SIDE CAP211
1123160000M6M M16HDGHEX NUT M16610
112617340017x34HDGWASHER ROUND129
1120161500M16x150HDGBOLT M16 68
8920032 HDGCONNECTION 17
112613240213x24x4HDGWASHER ROUND TBRUB16.3
1120120300M12x30HDGSCREW M12 16.2
8920505 HDG CONNECTOR PLATE16.1
8920301A (ASSAMBLED) HDGC-POST 140x40 16
112320000M6M M20HDGHEX NUT M2025
112621360021x36HDGWASHER ROUND104
1120120080M20x80HDGCARRIAGE BOLT M2023
8920531 / 89205302000 / 1500HDGBirsta "Nail" ANCHOR TUBE12
89200080 Birsta SafeEnd11
A
BC
D
Cop
yright
Birst
aver
ken
AB
SafeEnd 10Rev.Drawing no.
Date
ScaleCopiedDesign. Drawn Stand.Checked Appr. Replaces Replaced by
www.birsta.eu a SAFEROAD company
GLNGLN FSö GLN
2015-03-05
SafeEnd 10
Birsta SafeEnd P4PROFILE-B DUBLE
N/A
ASSEMBLY DRAWING In Review
652`20
8450SafeEnd ~ CONNECTION ~700
6800`20
250
1
2
345
OPTION: 8920081
PLASTIC COVER MOUNTED ON SITE WITH 6x
MAURUTEX SCREW A2 M5,5x20.
CAN BE PROVIDED WITH VARIOUS TYPE OF
REFLEX, POINTING TO RIGHT, LEFT OR
MIDDLE EX.
6
8 9 10
CONNECTING SYSTEM
DOUBLE SIDED PROFILE-B
HEIGHT 700 / 750 MM
HDG. IN PART LIST STANDS FOR HOT DIP GALVANIZING
ACCORDING TO EN ISO 1461
BOLT, SCREWS & NUTS ACC. TO EN ISO 10648
6.16.26.3
HEIGHT ACC. TO CONNECTING SYSTEM
8700`50
1900`20
REGULATIONS
ENV 1317-4
EN ISO 1461 (HOT DIP GAVANIZING)
ADDITIONAL INFORMATION
PERFOMANCE LEVEL: P4
IMPACT SEVERITY LEVEL: B
LATERAL DISPLACEMENT CLASS: D1.1
REDIRECTION ZONE: Z1
7
~ 29511
L=20
00 IN G
RAVEL
L=1500
IN A
SPHALT
![Page 5: 7 0 E S CONNECTION ~700 SafeEnd ~ 8450 REGULATIONS 7 ... · gln fsgln ö gln 1:20 2015-02-23 safeend 07 birsta safeend p4 profile-a left/right 507,9 kg assembly drawing in review](https://reader033.vdocument.in/reader033/viewer/2022050404/5f815ccbe4b227792461e115/html5/thumbnails/5.jpg)
A ( 1 : 5 )
B ( 1 : 5 )
C ( 1 : 5 )
8920082 / RSK75110.5BL PESafeEnd SIDE CAP211
1123160000M6M M16HDGHEX NUT M16610
112617340017x34HDGWASHER ROUND129
1120161500M16x150HDGBOLT M16 68
HDGCONNECTION17
112613240213x24x4HDGWASHER ROUND TBRUB16.3
1120120300M12x30HDGSCREW M12 16.2
8920505 HDG CONNECTOR PLATE16.1
8920301A (ASSAMBLED) HDGC-POST 140x40 16
112320000M6M M20HDGHEX NUT M2025
112621360021x36HDGWASHER ROUND104
1120120080M20x80HDGCARRIAGE BOLT M2023
8920531 / 89205302000 / 1500HDGBirsta "Nail" ANCHOR TUBE12
89200080 Birsta SafeEnd11
A
B
C
Cop
yright
Birst
aver
ken
AB
SafeEnd 11Rev.Drawing no.
Date
ScaleCopiedDesign. Drawn Stand.Checked Appr. Replaces Replaced by
www.birsta.eu a SAFEROAD company
GLNGLN LGN LGN 1:20
2015-02-26
SafeEnd 11
Birsta SafeEnd P4ER OBB
525,1 kg
ASSEMBLY DRAWING In Review
652`20
8450SafeEnd ~1544CONNECTION ~
6800`20
250
1
2
345
OPTION: 8920081
PLASTIC COVER MOUNTED ON SITE WITH 6x
MAURUTEX SCREW A2 M5,5x20.
CAN BE PROVIDED WITH VARIOUS TYPE OF
REFLEX, POINTING TO RIGHT, LEFT OR
MIDDLE EX.
6
8 9 10
CONNECTING SYSTEM
ER OBB
HEIGHT 720±30 MM
HDG. IN PART LIST STANDS FOR HOT DIP GALVANIZING
ACCORDING TO EN ISO 1461
BOLT, SCREWS & NUTS ACC. TO EN ISO 10648
6.16.26.3
HEIGHT ACC. TO CONNECTING SYSTEM±
8700`50
1900`20
REGULATIONS
ENV 1317-4
EN ISO 1461 (HOT DIP GAVANIZING)
ADDITIONAL INFORMATION
PERFOMANCE LEVEL: P4
IMPACT SEVERITY LEVEL: B
LATERAL DISPLACEMENT CLASS: D1.1
REDIRECTION ZONE: Z1
~ 29511
L=20
00 IN G
RAVEL
L=1500
IN A
SPHALT
998
7