Operation Manual
Stand-alone Controller
AR-727H
2005/12/16
1. Add - Card ID 2. Add - RF-learn 3. Suspend - Addr4. Suspend – ID #5. Delete - Addr 6. Delete – ID# 7. Recover - Addr8. Recover –ID # 9. Antipass Group
1.Add/Delete
2.User Setting
3.Parameters(1)
4.Parameters(2)
5.Tools
6.Quit
7.Quit & Arming
Function Menu
1.Node ID 2.Auto Open Zone 3.Door Relay Tm 4.Door Close Tm 5.Alarm Relay Tm 6.Alarm Delay Tm 7.Arming Delay Tm 8.Arming PWD 9.Arming Pulse
1.Password 2.Access Mode 3.Extend Options4.Single Floor 5.Multi Floors
1.Auto Relock 2.Egress(R.T.E.) 3.Attendance 4.Master Node 5.Force Open… 6.Close & Stop 7.Anti-passback 8.Duress Code 9.Factory Reset 0.Key(#) is Bell
1.Language 2.Master Code 3.Master Range 4.Terminal Port 5.AR721R32 Port 6.Open TimeZone 7.Informations 8.Clock Setting 9.Control Mode 0.View Events
1
Table of Contents Page
1. Main Feature --------------------------------- 4 2. Control Mode --------------------------------- 5 3. Notice --------------------------------- 6
How to know card ID of user address? -------------------------------- 6 LCD display show card ID except user address (ex. 00005) when the user flash card? -------------------------------- 6 How to know how many users in the system now? -------------------------------- 6 How to know which item at your hand? --------------------------------- 7 How to start/suspend (auto open zone)? ---------------------------------- 7 How to disarming? ---------------------------------- 7 How to restore master code to the factory default?--------------------------------- 7 How to reset all parameter to the factory default?----------------------------------- 7 How to set the time on AR-727H? ---------------------------------- 8 How to enable bell output? ----------------------------------- 8 How to check the historical records? ------------------------------------ 8
4. Front Panel & Functions ------------------------------------- 9 5. Mode 4 / 8 / 9 ------------------------------------- 10
5.1 Card Editing ------------------------------------- 10 5.2 Access Mode ------------------------------------- 11 5.3 Duress function ------------------------------------- 12 5.4 Force on/off code ------------------------------------ 12
6 Mode 6 ------------------------------------ 14 6.1 Card editing ----------------------------------- 14 6.2 Access mode ----------------------------------- 14
7 Quick Guide ----------------------------------- 15 8 Function description ----------------------------------- 16 9 Special designed --------------------------------- 19
9.1 Connecting one AR-727H with 2 AR-661U for Anti-pass-back ------------- 19 9.2 How AR-727 connects with a weigand reader (AR-721K, AR-721U, AR-661U) and to apply to anti-pass back --------------------------------- 20 9.3 How to set multi AR-727H connects with a net controller and to apply to anti-pass-back -------------------------------- 20 9.4 How to setting the weigand reader (AR-721U, AR-721K, AR-661U) and AR-727H at the same net controller to apply to the anti-pass-back -------------------------------- 20 9.5 How to set that user arrive single floor or multi-floor -------------------------- 21
2
9.6 How to set AR-401RO16 parameter ------------------------------ 22 10 Installation -------------------------------- 23
10.1 Step -------------------------------23 10.2 Installation Notice --------------------------------- 23
11 Wiring --------------------------------- 26 12 Installation diagram -------------------------------- 27
12.1 Magnetic lock -------------------------------- 27 12.2 Electric bolt lock -------------------------------- 28 12.3 Electric strike -------------------------------- 29 12.4 Magnetic door contacts and alarm system ---------------------------------- 30 12.5 Wiegand reader -------------------------------- 31 12.6 Networking installation -------------------------------- 32 12.6.1 two set of AR-716EV2 parallel installation ----------------------------- 33 12.6.2 AR-716EV2, AR-829E and AR-727H
parallel installation ---------------------------- 34 12.7 Lift controller AR-401RO16 installation ------------------------------- 35
12.1 AR-727H & AR-801CM & PC installation ------------------------------- 36 12.2 RS-232 Printer --------------------------------------------------- 37
13 Software Application ----------------------------------------------------- 38 14 Troubleshooting --------------------------------------------------------- 39 15 Return of Products ------------------------------------ 39 16 Warranty --------------------------------- 39 17 Transponder Record Table ---------------------------------- 40 18 Specification -------------------------------- 41
3
1. Main Features With waterproof, could be installed outside.
Special feature for stand-alone use:
◎ Keep last 1200 transactions
◎ Editable 2 time zone for door release purpose
◎ Controller needless anti-pass back:: AR-727H supports anti-pass back with its external reader.
Master Cards range assignable.
Unlimited Site Code.
Clear and big LCD panel with 4 line messages. (128 * 64 graphic)
One RS-485 Port supported for networking(via controller or directly).
Built-in one Door sensor and Arming on/off input.
Support with keypad locks immd & all cards entrance allowance before cards editing finished.
Support remote operation to relays on networking controller AR-716EV2/AR-716Ei via Force on/off code.
Support with Auto-relock automatically and keypad locked if continuous wrong code inputted.
Control mode, card capacity and card type assignable by user directly.
Built-in a proximity reader, a external wiegand reader port and IC card reader (optional).
Auto-discriminating between stand-alone & networking system, AR-727H could connect with controller AR-716EV2, AR-716Ei to have multi-door anti-pass back.
Alarm function available. (Tamper, Force entrance, door open too long)
Universal serial port supported for LED display, printer, lift controller, etc
4
2. Control Mode
AR-727HV3 MODE 4
Stand-alone MODE 6
Stand-alone MODE 8
Stand-alone Networking
Card user Capacity
1024 65536 1024 Depend on Controller
Access Mode Card only
Card & PIN User nbr. & PIN
Card only Card only
Card & PIN PIN only
Depend on
Anti-pass Back Single door × Single door Multi-door
anti-pass back (16 doors)
Control Mode in Networking
Mode 4 × Mode 8 Mode 4
Or Mode 8
Note WG32 WG 16 WG32 WG32
Lift control 32 stop
1024 card users×
32 stop 1024 card user
32 stop 1024 card
users How to set Mode 4 ,Mode 6 , Mode 8 and Mode 9:
Step1: * + 1 2 3 4 5 6 + # enter the “FUNCTION MENU” Step2: Tool / control mode (command:59)
1:M4 2:M6 3:M8 4:M9, input Mode value. tags format—1:EM 2:SOYAL, input card value.
Note: 1. M4=M9 In AR-727HV3 version. 2. Changing control mode “from Mode 6 to Mode 4” or “from Mode 4 to Mode 6”, it is
necessary to delete all card user data first. Depend on controller: For example, controller AR-716EV2 has 15,000 card users
capacity. Lift control: For 1024 card users, everyone could be assigned for single floor or
multi-floor access.
5
3. Notice Keep AR-727H away from the followings:
Keep away from magnets or any magnetized items. Do not apply strong shock to 727H
After flash master card and press F1 F2 F3 F4 or # within 2 seconds can enter the “FUNCTION MENU”. Master Cards range assignable. Default value: user address 00000 – 00004.
Each card has 10 digits code, including Site code (5 digits) and Card code (5 digits). Neither the Site Code nor the Card Code numbers can be 0.
After card editing finished, Site Code and Card Code is not important anymore. System will require a USER ADDRESS instead.
User can request to exit through the controlled door without using transponder (and without causing an alarm condition), by pressing an exit button. This will operate the door relay for the programmed door relay release time & stop alarm.
How to know card ID of user address? (For example: which card ID do we want to know user address 00003)
Step1: * + 1 2 3 4 5 6 + # enter the “FUNCTION MENU”
Step2: Add/Delete (command 1) Step3: Add / Card ID (command 1) Step4: Enter user address 00003, then you will see card ID. LCD display show card ID except user address (ex. 00005) when the user flash card?
How to do? Step1: * + 1 2 3 4 5 6 + #
enter the “FUNCTION MENU” Step2: Parameters (1) (command 3)
Step3: Node ID (command 1) Step4: Set Node ID Step5: Then, the system will ask if show card ID? 1. No 2. WG 3. ABA 4. HEX Cur.: 1 Step6: If select 2. WG, for example as follows: User address 00005 for card ID 00020:25000 When user flash card, LCD display will show both user address 00005 and card ID 00020:25000. Note that CPU version must be at least 4.1 or up. How to know how many users in the system now? (Not including suspend card)
Step1: * + 1 2 3 4 5 6 + # enter the “FUNCTION MENU”
Step2: Tools (command 5) Step3: Informations (command 7) AR-727H Ver 3.4 Users: 00010 (There are already 10 users in the system) How to know which item at your hand?
6
(For 125K system or Mifare system) Step1: * + 1 2 3 4 5 6 + #
enter the “FUNCTION MENU” Step2: Tools (command 5)
Step3: Informations (command 7) "AR-727H1356 V4.2""Users: 00000 ""Messages: " Or "AR-727H Ver 4.2 ""Users: 00000 ""Messages: " How to start/suspend (auto open zone)?
Step1: main manual Step2: tools (command 5) Step3: setting Open Time Zone (command 6) Step4: come back to main manual Step5: Parameters (1) (command 3) Step6: start Auto open zone function (command 2) Step7: Yes / No Note: The electronic lock would be locked until first one flash card on the reader when the system enter auto open time zone. And electronic lock will be locked that sensor feels door closed when system exit auto open time zone. How to disarming?
(1) User can be disarming by normal access mode once violating anti-pass-back resulting in alarm. (2) User can be disarming by valid card when alarm happen. (3) * + 1 2 3 4 5 6 + #
enter the “FUNCTION MENU” Step1: main manual
Step2: Parameters (2) (command 4) Step3: Close Door Stop Alarm (command 6), then enter 1: YES.
How to restore master code to the factory default (123456)? If the master code is forgotten it can be restored to the factory default (123456). Remove the AR-727H from the mounting plate, disconnect power, remove AR-727H CPU, install AR-727H-CLE CPU, and restore power about 10 seconds. Then disconnect power, remove AR-727H-LCE CPU, install AR-727H CPU, and restore power. How to reset all parameter to the factory default?
Step1: * + 1 2 3 4 5 6 + # enter the “FUNCTION MENU”
Step2: Parameters(2) (command 4) Step3: Factory Reset (command 9) Then, LCD display will show “Initial System……” message to reset all parameter to factory default. Note that CPU version must be at least 3.8 or up.
How to set the time on AR-727H?
7
Step1: * + 1 2 3 4 5 6 + # enter the “FUNCTION MENU”
Step2: Tools (command 5) Step3: Clock Setting (command 8) Step4: Input Date&Time YyMmDdHhMmSs How to enable bell output?
Step1: * + 1 2 3 4 5 6 + # enter the “FUNCTION MENU”
Step2: Parameter(2) (command 4) Step3: Key(#) is Bell (command 0) Step4: Press(#) On Bell 1:YES 2:No Data:0
Step5: Enter 1:YES How to check the historical records?
(1) Press * + 1 2 3 4 5 6 + # enter the “FUNCTION MENU”.
(2) “Tools (Command 5)” -> “View Events (Command 0)” (3) Then, you will see the following message from LED screen:
A 01/16 15:45:25 FRI 00001 001
User AddressWeek
TimeDate
Work Status :
A: Duty On
B: Duty Off
C: Overtime on
D: Overtime off
E: Break out
F: Break RTN
G: Go
H: Return
8
Serial Number
4. Front Panel Functions
Input ndicator Arming Green)
Alarm (Red)
Transmission: Receive (Green)
Send (Red)
Keypad Atte Press 1 time PresF1 Up Duty on BreaF2 Down Duty off BreaF3 Correct Overtime on Go F4 Overtime off Retu* Esc # Enter Other:
◎ Press * + Master Code (defauto enter “Function Menu”
◎ Before card editing finished, the + F4 for all cards entrance allow
◎ Press * + # to lock / unlock kFunctions: 1. System will automatically exit from
made within 30 seconds. 2. In FUNCTION MENU, LED [OK] w3. In card access mode, flashing qua
LED [OK] and LED [Reading] will shown [OK],
4. Flashing unqualified card on the uLED [ERROR] and LED [Readingmessage shown [Invalid Card!].
5. Green LED [ARMING] light up in “6. Red LED [ALARM] lights up if any7. Continuous wrong “PIN Code” or
seconds, LED [Error] light up and 8. Once Alarm arisen, user must pus
and return to standby state. 9. Transmission:
Receive [Green] lights up when it Send [Red] lights up when AR-727
a
]
“
ns
l
m
l
n
A
Lh
r
&
Error (Red)
OK(Green)
Reading (Green)
dance 2 times
k out k RTN
rn
t : 123456, changeable) + #,
aster could enter “Function Menu” and press 0 nce. eypad immd.
FUNCTION MENU, if no key or card entry is
ill flash continuously and quickly. lified card on the unit ight up, a beep sound and LCD panel message
it light up, two beeps sound and LCD panel
rming On”. abnormal condition arisen. Master Code” will make keypad locked for 30 CD panel shown [keypad Locked]. exit button or flashing qualified card to release
eceives message from PC or its external reader. H sends data to PC
9
5. Mode 4 / 8 Pre-explanation Arming PWD (4 digits)
Default value:1234 Could be setup via Function Menu (Function no. 38)
PIN Code (4 digits) Could be setup via Function Menu (Function no. 21) Or, via 701 Client \ Setting \ User card
Duress Code (4 sets, 4 digits) Networking System:
Default value:1111 ; 2222 ; 3333 ; 4444 Changeable via 701 Server\ Setting \ 701 Configuration \ Duress Code
Stand-alone System: Default value:4321 Changeable via Function Menu (Function no. 48)
Force on/off Code (4 sets, 4 digits) Networking System:
Default value:1111 ; 1111 ; 1111 ; 1111 Changeable via 701 Server\ Setting \ 701 Configuration \ Duress Code
5.1 Card Editing
After entering Function Mode, user uses following order to edit cards. Function Nbr.
Add→Card ID 11 Add→RF learn 12 Delete→Addr 15 Delete→ID# 16 Recover→Addr 17 Recover→ID# 18
How to edit ten pcs sequential cards? ( Default access mode is Card only) Step1: * + 1 2 3 4 5 6 + # enter the “FUNCTION MENU”
Step2: Add/Delete (command 1) Step3: Add→RF learn (command 2) Step4: Then, LCD display will show as follow: Please follow LCD display indicator to edit card Step5: InputStartAddr (0-00999)
Enter 1, start from user no. 1 Step6: Tag Uints (pcs) Must be Sequence (1-00999) Enter 10
Step7: Close Tag Into RF Area Present the lowest card code of card to the unit.
10
5.2 Access Mode Users can select one of the following access modes 5.2.1 Card Only
Access the door by flashing card
Open door & turn Arming on / off: Flash card, then press Arming PWD + F1
Not open door & turn arming on / off: Press * + Arming PWD, then flash card
5.2.2 Card and PIN Flash card, then press PIN Code + #
Open door & turn Arming on / off: Flash card, press PIN code & #, then Arming PWD + F1
Not open door & turn arming on / off: Not available How to set access mode of user is card and PIN? Step1: * + 1 2 3 4 5 6 + # enter the “FUNCTION MENU”
Step2: User Setting (command 2) Step3: Access Mode (command 2) Step4: Enter user number, Then, LCD display will show as follow:
1:Card 2:or PIN 3:& PIN 4:Pause Data: 1 Please select number 3: & PIN
Step5: Return to main menu to set the password of user Step6: User Setting (command 2) Step7: Password (command 1) Step8: Enter user number Then, LCD display will show as follow: Input 4 Digit No. Range:0001~9999 Data:
5.2.3 User address and PIN (Mode 4) Press keypad: User address (5 digit), then PIN code & # Open door & turn Arming on / off: User address, press PIN code & #, then Arming PWD + F1 Not open door & turn arming on / off: Not available How to set access mode of user is card or PIN?
Step1: * + 1 2 3 4 5 6 + # enter the “FUNCTION MENU”
Step2: User Setting (command 2) Step3: Access Mode (command 2) Step4: Enter user number, Then, LCD display will show as follow:
1:Card 2:or PIN 3:& PIN 4:Pause Data: 1 Please select number 2:or PIN
Step5: Return to main menu to set the password of user Step6: User Setting (command 2) Step7: Password (command 1) Step8: Enter user number
Then, LCD display will show as follow: Input 4 Digit No. Range:0001~9999 Data:
11
5.2.4 PIN only (Mode 8) Same as Card Only Or, press keypad ◎ Door access: PIN code (4 digit) ◎ Open door & turn Arming on / off:
PIN code & #, then Arming PWD + F1 ◎Not open door & turn arming on / off: Not available How to set access mode of user is PIN only?
Step1: * + 1 2 3 4 5 6 + # enter the “FUNCTION MENU”
Step2: User Setting (command 2) Step3: Access Mode (command 2) Step4: Enter user number, Then, LCD display will show as follow:
1:Card 2:or PIN 3:& PIN 4:Pause Data: 1 Please select number 2:or PIN
Step5: Return to main menu to set the password of user Step6: User Setting (command 2) Step7: Password (command 1) Step8: Enter user number, Then, LCD display will show as follow:
Input 4 Digit No. Range:0001~9999 Data: 5.2.5 Change PIN code
AR-727H connects with PC, running 701 client and set PIN code variable. By user: Flash card, then press PIN code (4 digit) twice + #) By 701 client \ setting \ user card Not connecting with PC Entering Function menu \ User setting \ Password
5.3 Duress function This function could help users to send a message to the computer asking for help. Only available in networking state, running 701 Server and setting 4 sets of Duress code on
PC. (Anyone of these 4 sets is workable.) This function is not available for CARD ONLY access mode and mode 8 directly
4-digit PIN.
Access Mode Command Format Card Only Not available Card and PIN Flash card, then press Duress code & # Users addr. and PIN (Mode 4)
Press user address, then Duress code & #
PIN Only (Mode 8) Duress code 5.4 Force on/off Code (4 sets, 4 digits)
Only workable in networking system, running 701 Server and setting 4 sets of Force code on PC. (Anyone of these 4 sets is workable.) User could press related code to turn on / off its connected equipment, diagram as below.
12
PC board of Controller AR-716EV2 / AR-727E
COM
JP4
V12CN5
DI.4
DI.2DI.1
DI.3
COM
D10D9
D11
K4RELAY
K3
D12
RELAY
JP3
K1
K3K4
K2K2
RELAYRELAYK1
Relay Code K1 16 K2 17 K3 18 K4 19
After access OK, press following order to turn on / off its connected equipment.
Access mode ON/Off Order
ON Flashing card+Force code+Code+0+# Card only
Off Flashing card+Force code+Code+1+#
ON Flashing card+User code +Force code+Code+ 0+# Card + user
code Off
Flashing card+User code +Force code+Code+1+#
ON User no. +User code +Force code+Code+ 0+#
User no. + user code (Mode 4)
Off User no. +User code +Force code+Code+ 1+#
ON User code +Force code+Code+0+# User code only
(Mode 8) Off User code +Force code+Code+1+# This function is good for force control television, air conditioning, audio, etc. by Relay-1, 2, 3, 4 on the multi-door networking controller. To avoid the conflict of the use of each controller relay, it is user responsibility to define each controller relay for one purpose use only.
13
6. Mode 6 6.1 Card Editing
Under Mode 6, the system built in card code from 00001 to 63200 itself, so user can only suspend or recover cards, not allowed to add or delete. The card which its card code is over than 63200 can’t be used under Mode 6. After entering Function Mode, user uses following order to edit cards.
Function Nbr. Suspend→Addr 13 Delete→Addr 15 Recover→Addr 17
How to start / stop using cards? Example: Start using cards, which card ID from 12345: 00001 to 12345: 00100,
totally 100 cards in sequence. Step1: Entering Function Mode Step2: Recover -> Addr. (Order no. 17) Step3: Input Start Addr. -> 00001 Step4: Input End Addr.-> 00100 Succeed!
6.2 Access Mode Under Mode 6, with different Arming PWD and Duress Code, users have different access mode as below.
Arming PWD = 0
Arming PWD ≠0
Duress Code =0
Duress Code ≠0 Mode 6
Access Mode Card only Card and Arming PWD
Duress Code not workable
Duress Code only
14
7. Quick Guide (Function Menu) Under Function Menu, you could just press the indicative nbr. to get into concerning set-up screen directly.
Function Nbr. Function Nbr. Add→Card ID 11 Alarm Relay Tm 36 Add→RF – learn 12 Arming Delay Tm 37 Suspend→Addr 13 Arming PWD 38 Suspend→ID # 14 Arming Pulse 39 Delete→Addr 15 Delete→ID # 16 Auto Relock 41 Recover→Addr 17 Egress (R.T.E.) 42 Recover→ID # 18 Attendance 43 Antipass Group 19 Master Node 44 Force Open.. 45 Password 21 Close & Stop 46 Access Mode 22 Anti-pass back 47 Extend Options 23 Duress Code 48 Single Floor 24 Multi Floors 25 Language (English) 511 Master Code 52 Master Range 53 Terminal Port 54 AR721R32 Node 55 Node ID 31 Open Time Zone 56 Auto Open Zone 32 Information 57 Door Relay Tm 33 Clock Setting 58 Door Close Tm 34 Control Mode 59 Alarm Relay Tm 35 View Events 50
15
8. Function description 24 Single Floor To setup user for single floor access
(This function is only workable under the situation that AR-727H combined with AR-401RO16 and Control Mode is not Mode 6.)
25 Multi Floors To setup user for multi floors access (This function is only workable under the situation that
AR-727H combined with AR-401RO16 and Control Mode is not Mode 6.)
For example: User 0001 access to floor 17, 22, 31, 32 (Supposed no basement)
1. Entering “Function Menu” 2. Press 25 3. Enter user address: 00001 4. Select range: 2 (for 17 – 32)
1: 01 –16 2: 17 – 32 5. 0 -> stop 1 -> Yes
1000010000000011 31 Node ID To setup Node ID (default: 001), range from 001 to 254 33 Door Relay Tm To setup how long the time will be that door close after a card
flashing. Range: 0 ~ 600 (sec.) To set value “0” will make door keep opening, after 2nd card flashing, then door close. (Default value: 7 sec.)
34 Door Close Tm Extended time for door opening time. (Default value: 15 sec.)
35 Alarm Relay Tm When abnormal condition arisen, how long the alarm will take place. Range: 0 ~ 600 (sec.) To set value “0” will make alarm relay keep on until disarming, then alarm relay off. (Default value: 7 sec.)
36 Alarm Delay Tm The time between setting Alarm on and its real starting working time. (Default value: 1 sec.)
37 Arming Delay Tm The time between setting Arming on and its real starting working time. Range: 0 ~ 600 (sec.) (Default value: 1 sec.)
39 Arming Pulse Range: 0 ~ 2500 (sec.) TTT = 000: Latch (Toggle)
(Default value: 1 sec.) 56 Open Time Zone Set door open / close automatically. Details:
1. Enter “Function Menu” 2. Setup opening time first, Function no. 56 3. Auto Open Zone, Function no. 32
1: Yes 2: No
16
Drawing explanation: 1. Time schedule for Door Relay, Wait Delay (Door Close Tm),
Alarm Delay, Alarm Relay
Door Close Tm
Alarm Delay
Alarm Relay
Door Relay
K
2.
Arm Tim
Tim
SigArm
SigArm
ArmSig
Seq
Flashing card O
Arming Delay, Arming on
Arming Delay
Arming Relay
Flashing card OK
If abnormal conditions arisen, will cause Alarm E.g. Door open too long (over allowed time) Force open
Vi l i i b k l i
ing Delay Timing
ing 1 Sequence-
Arming Delay Timeing 1
Check Point AArming is set
nal Outputing
nal Outputing
If TTT = 000Level Triggle
ingnal Output
If TTT = 200Pulse Trigger
Pulse TriggerIf TTT = 050
0.5 Second
2.0 Seconds
uence
17
After arming is set, the system enters TTiimmiinngg 11 SSeeqquueennccee. Right on CChheecckk PPooiinntt AA, the system is in arming situation and enters Arming Mode, if door is close, the system engages the Timing 2 Sequences, if door is open, it will wait until the door is closed to engage the Timing 2 Sequences. Timing 2 Sequences-
Door opened by not using “Forced Open”: In arming situation, the system enters TTiimmiinngg 22 SSeeqquueenncceess once the door is opened by not using “Forced Open”. During TTiimmee PPeerriioodd BB, the system is back to arming situation if door closed, if door is still open right on CChheecckk PPooiinntt CC, alarm is activated after TTiimmee PPeerriioodd DD. User can disarm the system in TTiimmee PPeerriioodd DD to avoid the alarm generated, or disarm the system in TTiimmee PPeerriioodd EE to turn off the alarm which is activating. Door opened by using “Forced Open” and if “Forced Open” feature, Command 28, is disabled:
Timing 2Sequences
Alarm TimeAlarm Delay Time
Check Point C
Arming Idle TimeDoor Unlock Time
Door is opened
Time Period B Time Period D Time Period E
In arming situation, the system enters AAllaarrmm DDeellaayy TTiimmee right away once using “Forced Open” opens the door and if “Forced Open” feature is disabled. The alarm is activated after TTiimmee PPeerriioodd DD. User can disarm the system in TTiimmee PPeerriioodd DD to avoid the alarm generated, or disarm the system in TTiimmee PPeerriioodd EE to turn off the alarm which is activating. Door opened by using “Forced Open” and if “Forced Open” feature, Command 28, is enabled: In arming situation, the alarm is generated and system enters AAllaarrmm TTiimmee right away once using “Forced Open” opens the door and if “Forced Open” feature is enabled. User can disarm the system in TTiimmee PPeerriioodd EE to turn off the alarm that is activating. Signal Output Arming or Disarming Signal Output- RED WHITE, CN2 Once arming is set, after Arming Delay Time period, the system generates a Level Trigger if TTT=000, and a Pulse Trigger if TTT>000 and the time period of the Pulse Trigger is based on the calculation 0.01xTTT second(s). For TTT=000, entering the Edit Mode or disarming the system will reset the Level Trigger. For TTT>000, entering the Edit Mode every time or disarming the system will generate a Pulse Trigger.
18
Arming Delay TimeTiming 1Sequences
In Arming ModeArming is set
Signal OutputArming
Signal OutputArming
If TTT = 000Level Triggle
ArmingSignal Output
If TTT = 200Pulse Trigger
Pulse TriggerIf TTT = 050
0.5 Second
2.0 Seconds
Disarmingor
Edit ModeEnter
Edit ModeEnter
Arming Switch Setting Signal Output- ORANGE WHITE, CN2 Once Arming switch is pressed, a Level Trigger is generated until Arming switch is released to reset this signal.
Card Present Signal Output- Brown, CN2 Any identifiable tag in the RF field, it will output a low level signal; a Level Trigger is generated until a tag is absent to reset this signal.
9. Special Design 9.1 AR-727H connected with 2 pcs of AR-661U long-range reader (Set one
AR-661U being Exit reader and the other one being Entry reader) to apply to Anti-pass back.
Identifiable tag Absent
Identifiable tag Present
Card Present Signal Output
Release uttonfor disarming
Press button forSet Arming
Arming Switch Output
CPU version must be at least 3.2 or up. In stand-alone system, without connecting to any controller, AR-727H could
integrate with 2 pcs of AR-661U to apply to anti-pass back. ◎ No special setting up necessary for AR-727H. ◎ Set one AR-661U with wiegand 34 bit format output and the other one with
38 bit. (Please refer to manual of AR-661U to have details.) ◎ Set card to have anti-pass back checking.
(Order no. 19) This special design is especially suitable for car parking control. The special design is only workable with AR-661U, not available with AR-721U,
AR-721K. (wiegand reader) Soyal Product AR-829E (CPU version at least 5.6) 、AR-721H4 (CPU version at
least 3.1V) also have this special design. The original function that AR-727H connecting with one wiegand reader
(AR-661U, AR-721U, AR-721K) to apply to Anti-pass back is still available.
19
9.2 How AR-727 connects with a weigand reader (AR-721K, AR-721U, AR-661U) and to apply to anti-pass back?
(1) Main manu (2) Input command:47,
enable antipass—1:YES 2:NO,input1; in or out –1:in 2: out,input default value(1 or 2 ).
attention:if AR-727H would be in door and then the weigan reader would be out door.
9.3 How to set multi AR-727H connects with a net controller and to apply to anti-pass back?
Both card and reader have to apply to anti-pass back. 1.card setting:
step1:701 Client step2:user card edit step3:mark anti-pass back.
. 2. reader setting (AR-727H): step1:main manu step2:command 47 step3: enable antipass—1:YES 2:NO,input1;
in or out –1:in 2: out,input default value(1 or 2 ).
9.4 How to setting the weigand reader (AR-721U, AR-721K, AR-661U) and AR-727H at the same net controller to apply to the anti-pass back?
Both card and reader have to apply to anti-pass back Card setting: step1:701 Client
step2:user card edit step3:mark anti-pass back. Hardware setting: weigand reader (AR-721U, AR-721K): Set controller WG port as in or out if WG port is port 1 then would be in door and port 2 would be out door.
Port 1 (Channel 17)
Port 2 (Channel 1
20
AR-716Ei PCB
8)
Software setting: 701 Server. Step1: 701E Parameter Step2: door number Step3:mark [Door Number 17]or [Door Number 18]
AR-727H setting: (1) main manu (2) command 47
enable anti-pass back 1:YES 2:NO,input1; in or out –1:in 2: out,input default value(1 or 2)
Attention: if weigand reader would be in door then AR-727H would be our door. 9.5 How to set that user arrive single floor or multi-floor?
Either way to set user arrive single floor or multi-floor function. 1. Set by keypad for standalone installation (AR-727H+AR-829L485+AR-401RO16) Set user arrive single floor
Step1: * + 1 2 3 4 5 6 + # enter the “FUNCTION MENU”
Step2: User Setting (command 2) Step3: Single Floor (command 4) Step4: Enter user address and set to access which one floor. Set user arrive multi-floor
Step1: * + 1 2 3 4 5 6 + # enter the “FUNCTION MENU”
Step2: User Setting (command 2) Step3: Single Floor (command 5) Step4: Please refer to “function description” to get detailed
explanation. 2. Set by software for networking installation
(PC+AR-801CM+AR-716EV2+AR-727H+AR-829L485+ AR-401RO16)
21
Go to 701 Client \ User card edit \ User Access Floor Edit Select User. Select controller and reader node that manages that elevator. Select the card user can access which floor. Click “Write to Controller”.
9.6 How to set AR-401RO16 parameter?
(ex. Card Release Tm) Step1: * + 1 2 3 4 5 6 + # enter the “FUNCTION MENU” Step2: Tools (command 5)
Step3: AR-721R32 Node (command 5) Step4: Input NodeID, Card Release Tm and P.B Release
Tm (Default value: 7 sec.) Note: 1. AR-401RO16 has no push button input function, but you still enter push button input second in order to complete this command. Otherwise, this command will be failed. 2. They are one-way transmission is between AR-727H and AR-401RO16, so you will find that you change Card Release Tm from 7 sec. to 10 sec. But the parameter will be stay default value 7 sec. Don’t worry about this matter. Actually, it is already changeable.
22
10. Installation 10.1 Steps: 1. Use the screwdriver to screw the mounting plate on the wall. 2. Pull cable ends through the access hole in the mounting plate.
Connect plug 7 pins to socket CN1 Connect plug 4 pins to socket CN2 Connect plug 8 pins to socket CN3 Connect plug 3 pins to socket CN5
3. Attach AR-727H to the mounting plate and install screw (supplied) into the hole at the bottom with the Allen wrench (supplied).
4. Apply power. Green LED [POWER] will light up, a beep sound and LCD panel message will show up.
10.21. T
aAo
2. Tadb
3. E4. A
sRiw
5. Psrp
Installation Notice: he distance between AR-727H and its auxiliary reader should be more than 50 cm nd less than 12 meter. (Suggested value) R-727H could be fixed inside the secure area as an exit and its auxiliary reader utside as an entrance reader, but not directly behind AR-727H. he reading range of AR-727H will be up to15 cm. However, when AR-727H or its uxiliary reader is mounted directly on a metal surface, the reading distance ecreases slightly. To reduce this effect, we suggest inserting a wood or plastic etween the mounting surface and the unit. xit Switch input must be a dry contact, without voltage present. R-727H does not supply power to operate electric strike or magnetic locks, a eparated power supply are required. efer to strike or magnetic lock manufactures instructions, if common power supply
s used for both AR-727H and electronic door lock; make sure to install the diode, hich is provided with AR-727H. ower supply should be at least 9 VDC to max. 24 VDC and at least 3W. DC power hould be clean and filtered with no more than 0.3 VAC ripple (Peak to Peak). Do not un AC power in the same cable with DC power to AR-727H. While it is always referable to use a separate power supply for AR-727H and strike.
23
6. Run the following cables to the AR-727H location. Conduit is recommended to reduce the effects of EMI/RFI and for physical protection of the wires.
Cable Types and Distances Wire Application Cable Type Description From Power Supply 2-cond, 18-22 AWG n/a From Locking Device and power supply or gate operator
2-cond. See Mfr’s Specifications
n/a
From external alarm system’s Door Monitor Switch (for shunting)
2-cond, 18-22 AWG 100 m
From Exit Button 2-cond, 18-22 AWG 100 m From Optional Auxiliary Reader 2-cond unshielded 22 AWG,
plus a separate 4-cond, shielded 22-24 AWG cable
50 cm - 12 m
7. Hardware connecting distance suggestion as follows:
a. RS-232: The distance between PC and converter (AR-801CM) can not be more than 2 meters
b. RS-485: The distance between converter (AR-801CM) and the farthest controller (or reader) can not be more than 300 meters. c. Wiegand: The distance between RS-485 reader (or controller) and Wiegand reader can not be more than within 3 to 5 meters.
d. Do not run AC power in the same pipe with communication wire (See drawing 2). It should be separate installation (See drawing 1).
(Drawing 1)
Separate installation Reader Lock
LockIn the same pipe
Reader
(Drawing 2)
24
8. We suggest that the customer use ”Shield Twisted Pair” and avoid Star wiring for good communication when installation. a. We suggest using the following cable in RS-485 communication.
b. Please use the following installation method, it is correct.
c. Don’t use the following installation method, it will cause communication error.
801CM ORController
Controlle ORReade
rvr
801CM ORController
Controller ORReader
xx
v
25
11. Wiring
Table 1 - Connector CN3 Color Coding Wire Application Wire Color Description
1 Blue White (N.O.)DC24V1Amp Door Relay 2 Purple White (N.C.)DC24V1Amp Door/Alarm Relay 3 White (COM)DC24V1Amp Door Sensor 4 Orange Negative Trigger Input Exit Switch 5 Purple Negative Trigger Input Alarm Relay 6 Gray N.O. / N.C. Optional
7 Thick Red DC Power 12V Power 8 Thick Black DC Power 0V
Table 2 - Connector CN1 Color Coding Wire Application Wire Color Description
1 Thick Green RS-485(B-) Networking 2 Thick Blue RS-485(A+) 3 Thin Blue Wiegand DAT:1 Input
ABA Clock Input Wiegand 4 Thin Green Wiegand DAT:0 Input ABA Data Input
Buzzer 5 Pink Buzzer Output 5V/100mA, Low 6 Brown LED Green Output 5V/20mA, MaxLED 7 Yellow LED Red Output 5V/20mA, Max
Table 3 - Connector CN5 Color Coding
Wire Application Wire Color Description 1 Red N.C. 2 Orange COM Tamper Switch 3 Yellow N.O.
Table 4 - Connector CN2 Color Coding
Function Wire Color Description Arming Setting Switch 1 Orange
White Latch type
Serial Port 2 Yellow White
Serial output (Transisto(4800,N,8,1)
Arming LED 3 Red White Arming output (Active low)
Card Present 4 Brown White
Card present output active (Transit output)
COM
NO
NC
JP1 Alarm Relay
Door Relay K1
K2
26
OFF
ONr open collector)
low
Purple White
Blue White
Gray
White
12. Installation diagram 12.1 Magnetic lock
NO.
COM.- G
ND
+12VDC
The installation of 727H and magnetic lock
Whi
te(
CO
M. )
Lock
( -G
ND
)P
urpl
e W
hite
( N
.C. )
-GN
D
Power Supply12VDC 2A
Pur
ple
Bla
ck(
- GN
D )
Red
( +
12V
DC
)
DOOR EXITPush Button
CN
3
Power Supply12VDC 2A
Lock(+12VDC )+12VDC
Magnetic Lock
CN3
AR-727H
CN5
CN1
CN
2
27
12.2 Electric bolt lock
- GND
- GND
+12VDC
NO.
COM.
12VDC 2APower Supply
The installation of 727H and electric bolt lock
Push ButtonDOOR EXIT
Pur
ple
Bla
ck(
- GN
D )
Red
( +
12V
DC
)
CN
3
Blu
e W
hite
( N
O. )
Whi
te(
CO
M. )
Lock( -GND )
Lock(+12VDC )12VDC 2APower Supply Electric Bolt Lock
CN5
AR-727H
CN
2
CN3CN1
+12VDC
28
12.3 Electric strike
+12VDC- GND
NO.
COM.
The installation of 727H and electric strike
Power Supply12VDC 2A
DOOR EXITPush Button P
urpl
e
Bla
ck(
- GN
D )
Red
( +
12V
DC
)
Blu
e W
hite
( N
O. )
Whi
te(
CO
M. ) C
N3
Lock(+12VDC )+12VDC12VDC 2APower Supply
Electric Strike
Lock
( -G
ND
)
-GN
D
AR-727H
CN5
CN3CN1
CN
2
29
12.4 Magnetic door contacts and alarm system
- GN
D
+12
VD
C
ALM
.
N.C
.
CO
M.
N.O
.
+12
VD
C
- GND+12VDC
The installation of 727H, magnetic door contacts and alarm system
Alarm System
Power Supply12VDC 2A
Bla
ck(
- GN
D )
Red
( +
12V
DC
)
Gray( ALM. )
Red
( +
12V
DC
)
Bla
ck(
- GN
D )
Mag
netic
Doo
r C
onta
cts(
CO
M. )
CN
3
Ora
nge(
Doo
r S
enso
r )
Mag
netic
Doo
r C
onta
cts ( NC
. )
12VDC 2APower Supply
Magnetic doorcontacts
CN1
CN5
AR-727H
CN
2
CN3
30
12.5 Wiegand reader
Green
Blue
Yellow
PurpleBrown
The
inst
alla
tion
of 7
27H
and
aux
iliar
y re
ader
s
721U
12V
DC
2A
Pow
er S
uppl
y
Red
(+12
VD
C)
Bla
ck
Red
1
721K
Red
Black
CN
1
1
~
Yel
low
Bro
wn
CN
2G
reen
Pin
k
Blu
e
661U
Bla
ck(-
GN
D)
Bro
wn
Yel
low
Gre
en
Pin
k Blu
e
727H
CN
3
CN
1
31
AR
-737
U
Bla
ck
Pow
er S
uppl
y12
VD
C 2
A
The
inst
alla
tion
of 7
27H
and
aux
iliar
y re
ader
s 73
7U
Red
Purple
Blue
Green
BrownYellow
AR-727H
Yel
low
Bla
ck(-
GN
D)
Red
(+12
VD
C)
1
CN
3
Gre
en
Bro
wn
Pin
k
Blu
eC
N1
32
12.6 Networking installation 12.6.1 two set of AR-716EV2 parallel installation
ToN
ode:
009
Nod
e: 0
16
ToN
ode:
008
Nod
e: 0
01
Not
e:1.
The
conn
ectin
g di
sanc
e be
twee
n th
e 80
1cm
and
you
r pc
can
not
be
mor
e th
an 2
m.
AR
-727
H
AR
-727
HA
R-7
27H
Green
Blue
Blue
Green
Green
Blue
Green
Blue
CN
1
CN
1C
N1
conn
ect t
o P
C
15V
DC
2A
Pow
er S
uppl
y
Con
trol
ler
Nex
t
Red
Bla
ck
Blue
BlackGreen
Red
AR
-727
H a
nd A
R-7
16E
/727
E n
ewor
king
inst
alla
tion
AR
-716
E
o
r
AR
-727
E
CN
1C
N3
CN
3C
N1
CN
5
CN2
~~
CN
1
~~
CN
1C
N3
CN
5
CN2
CH
1
JP2
JP1
HO
ST
CN
3C
H2
CN
2
BV
+
Vin
Vin
GN
DB
V-
727i
CN2
AR
-727
H
CN
5
CN
3C
N1
CN2
CN
5
~~~~
JP1
JP2
Vin
Vin
BV
+B
V-
CN
2
CN
1 CN
3
CH
1
HO
ST
CH
2
727i
AR
-716
E
o
r
AR
-727
E
GN
D
CN
1
33
12.6.2 AR-716EV2, AR-829E and AR-727H parallel installation
727i
CN
3 Red
JP1
JP2
Bla
ck
CH
2
HO
ST
CN
2C
N1
CN
2
AR
-727
H, A
R-8
29E
and
716
EV
2 ne
twor
king
inst
alla
tion
CN
2
Green
Blue
AR
-829
EA
R-7
27H
線紅
線黑
GN
D
VinCN
1V
in BV-
BV+
綠 線線藍
~~
CH
1
Pow
er s
uppl
y15
VD
C 2
A
CN2
CN
1
CN
5
CN
3
AR
-727
H
Blue
Green
至
Nod
e: 0
09
Nod
e: 0
16
CN
1
CN
3C
N1
CN
5
CN
1
Green
Blue
CN
3
CN
5
CN
1
CN
1
Green
Blue
CN2
AR
-727
H
CN2
Nex
t Con
trolle
r
~~
AR
-716
EV2
or
AR
-727
Ei
Min
imum
2 m
eter
conn
ect t
o P
C
34
12.7 Lift controller AR-401RO16 installation
Pow
er S
uppl
y12
VD
C 2
.4A
Dia
gram
of A
R-7
27H
and
AR
-401
RO
16
Bla
ck
Yel
low
-+
CN
CN
1
CN
CN
3
Red
Red
+
- +
Bla
ck
DC 12V
Gre
en
Blu
e
--+
+-
+-
35
12.8 AR-727H & AR-801CM & PC installation
The installation of 727H, 801CM and PC
12VDC 2APower Supply
Push ButtonDOOR EXIT
COM.
NO.
Red
( +1
2VD
C )
Bla
ck (
- GN
D )
Pur
ple
Whi
te (
CO
M. )
Blu
e W
hite
( N
O. )
12VDC 2APower SupplyElectric Bolt Lock
Lock ( -GND )
Lock (+12VDC ) +12VDC
- GND
CN3
AR-801CM
CN
2CN1
CN3CN1
CN5
Blue
Green
Power Supply15VDC 2A
AR-727H
Gre
en
Minimum 2 meterconnect to PC
To PC
Blu
e
Black
Red
36
12.9 RS-232 Printer 12.9.1 Printer setting - Baud rate: 4800, N, 8, 1 12.9.2 Hardware installation 1
1D0000000 Tm
The Wiring of 727H and printer (SH24)
TP1 DATA4K7
V12
GND
Serial Port (2nd Pin of CN2)
Yellow White
AR-727H
4K7
BGND
E
B
C
EC
C1815TX
DB25 male
Replace Circuit (Distance between AR-727H & SH24 Printer <1M)
Suggest Circuit
MAX232A
TX
Black (8th Pin of CN3)Pin GND7
Pin RX (in)2
SH24Printer
2.9.3 Hardware serial port format – select “printer format” Step1: * + 1 2 3 4 5 6 + #
enter the “FUNCTION MENU” Step2: Tools (command 5)
Step3: Terminal Port (command 4) Step4: 1: AR401RO16 2: LED 3: PRN 4: Duress Current Data: 1 Please enter 3, let serial port become printer format.
2.9.4 Print result ate Week Time Card ID Status 5/03/2004 MON 20:24:16 0000000248 Power On Ver 3.5 5/03/2004 MON 20:24:18 02: Reader Off Line 5/03/2004 MON 20:24:22 0000000250 Clear Message!! 5/03/2004 MON 20:25:01 01: Set Clock! 5/03/2004 MON 20:25:30 01:00001 Card Access OK 5/03/2004 MON 20:26:20 01: Egress! 5/03/2004 MON 20:35:23 01:00001 Card Access OK
he above data is printer when someone flash card, Egress, power on/off, clear essage and set clock. But note that the data will be not printed from invalid card.
37
13. Software Application 13.1 Configuration PC + AR-801CM + AR-727HV3 13.2 The difference between AR-727H and AR-727HV3 AR-727HV3 CPU: Version 5.1 UP / Hardware: 24LC256 13.3 Software Version Support 701 Server Ver 6.22 & 701 Client Ver 6.28 13.4 Software function via PC 1. Eleven sets of Time Zone (set via Time Zone Edit)
a. From Time zone 1 to Time zone 11 b. Support to linkable for each zone. c. Support the holiday if enable
2. Up to 120 holidays that can be set in a year starting from the editing date. (set via Holiday Edit)
3. Different time zone for each user (set via User Card Edit) 4. Which code will show in daily transaction record? Code Status Code Status M11 Normal Access M03 Invalid M16 Door open via Egress Button M17 Alarming M04 Time Zone error M30 Anti-pass-back error M01 PIN code error 5. Time and Attendance function 6. Work status of LCD display of the reader when standalone
View Message when standalone, it will show work status on left top corner if it is normal access (See Also: historical records page 10). Other will show code.
7. Auto-show work status (set via Time Zone Edit) a. Time zone 00 (Default), range from Sunday to Saturday. b. Work status 00:00 – 00:00 stand for fixed Duty on in work status 23:59 – 23:59 stand for fixed Duty off in work status 00:01 – 00:01 stand for retain last status that user press in work status XX:XX – YY:YY stand for as follows: For example, 09:00-18:00 Work status will show Duty on before 9 o’clock, show Duty off between 9 o’clock and 18 o’clock and show Overtime Off after 18 o’clock.
38
14. Troubleshooting
Questions Answer No appearance 1. Check power, if it is 9 – 24 VDC adaptor?
2. Check if the polarity is correct?
Can not connect to PC 1. Check if Transmission LED light up? (Green / Red) 2. Check 701 Server, if set-up is correct?
Please refer to 701 Server manual for details. 3. If connecting to PC via AR-801CM converter, check if the
power (Green) light up?
How to find out Card ID with a user address?
1. Entering “Function Menu” 2. Press 11 3. Entering “user address”
How many Cards exist in system?
1. Entering “Function Menu” 2. Press 57
15. Return of Products Please contact the distributor who sold the unit. All service and repairs must be done through an authorized distributor. 16. Warranty SOYAL warrants that the product(s) shall be free from manufacturing defects in materials and workmanship for a period of twelve (12) months from the date of delivery provided that the product was properly installed and used. The foregoing warranty shall not apply to defects resulting from abuse, misuse, accident, unauthorized alteration or repair, neglect, acts of God (such as floods, fire, etc.). SOYAL shall, at its option, either repair or replace product(s) which prove to be defective within the warranty period. SOYAL will replace any product found to be defective within the first three months of purchase provided said product was properly installed and used. Distributor agrees to insure the product or assume the risk of loss or damage in transit to prepay shipping charges and to use the original shipping container or equivalent. Customers shall seek assistance from the distributor who sold you product(s). Repaired or replaced product(s) are warranted for ninety (90) days from the date of repair or replacement, or for the remainder of the original product’s warranty period, whichever is longer.
Note: Don’t tear a paster such as S/N: 727H Warranty B-0307-000107 on the PCB board, it is SOYAL warranty.
39
17. Transponder Record Table Be sure to record the user number, the user name, the card ID number (site code: card code), and the user code and keep this information in a secure place. A black user log form has been included for purpose. Do not write on this form; use it as a photocopy master.
User Add. User Name Site code: Card code PIN code
Programmed by: Date:
Company Name:
Company Address:
City:
Other Information:
40
18. Specification
Power Supply 10 – 24 VDC
Power Consumption <3W (250 mA @ 12VDC)
RF Frequency 125 KHz
Reading range 10 – 18 cm
User Interface 16 metallic texture keypads、beep、128*64 dot LCD panel and 8 LED indicator.
Networking RS – 485, 9600,N,8,1
External reader port Suitable for all WG、ABA reader; 125K、13.56M (Mifare) or 2.4G reader
Door Relay 2A / 12V N.O. / N.C. / COM 0.1 ~ 600 sec. / Latch type
Alarm Relay 2A / 12V N.O. / N.C. / Jumper selectable 0 ~ 600 sec.
DI input Egress button /Door sensor/Arming switch
Transistor output Arming /Duress /Card sensor
Tamper switch Limit Switch(N.O. N.C. COM.)
Serial Port Supported for AR-721R32、LED display、 Relay board、Printer etc.(4800,N,8,1)
Material ABS
Dimensions(mm) 127 (L) * 91 (W) * 46 (H)
Net Weight 250 gram