75 ohm coaxial catv cable -...

28
75 Ohm Coaxial CATV Cable Product Selection Guide

Upload: ngocong

Post on 19-Sep-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

75 Ohm Coaxial CATV CableProduct Selection Guide

For information regarding specific cables, please visit www.pctinternational.com.© 2007-2010 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

contents

introduction 1

training & support 2

hardened drop solution 2

cable construction 3

product applications and part numbers 4

specifications 5 RG 6 5

RG 11 10

RG 59 15

headend 18

hybrid coax / twisted pair 19

attenuation tables 22

packing / shipping details 23

contact 25

Subscriber Cable DivisionPCT International, Inc.Yantai, PRC Factory

75 Ohm Coaxial CATV CableProduct Selection Guide

1

www.pctinternational.comFor information regarding specific cables, please visit www.pctinternational.com.© 2007-2011 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

PCT International’s MOCSY®7 75 Ohm

coaxial CATV cable is the reliable,

cost-effective solution for today’s bi-directional broadband systems.

Designed and manufactured entirely by PCT International, MOCSY7

cable offers service providers the lowest possible cable cost to access

subscribers, while meeting or exceeding SCTE specifications to ensure

reliable, long-life performance. Additionally, MOCSY7 is now specified

to MoCA frequencies.

PCT’s MOCSY®7 coaxial cable with patent pending

TRITON technology

incorporates an enhanced layer of foil to

provide superior shielding performance

while maintaining the physical profile and

ease of installation that characterize the

entire MOCSY7 line.

One of the most significant advances in the

history of coaxial cable design, MOCSY7

coaxial cable with TRITON technology has

been proven to deliver optimal service

quality in extended use in harsh environments. With the enhanced layer

of foil, TRITON provides a 20 db improvement in shielding after 10,000

flexes as compared to other manufacturer’s cable.

PCT’s Z-Wire™ drop cable with revolutionary corrosion

resistant technology combines true protection for

your network with ease of installation. PCT’s Z-Wire utilizes a patented,

water based, environmentally friendly binding process to deliver the

“zero corrosion” performance that ensures the highest levels of network

integrity for today’s sophisticated consumers. The dry, permanent

coating on Z-Wire cable prevents corrosion from weather and air

pollution and ensures system reliability and performance over time. And

because the coating is dry, it is easier for installers to quickly complete a

clean, secure, installation.

PCT coaxial cable with 1Prep™ rapid preparation

technology bonds the cable jacket with the outer tape.

This time saving process removes both the jacket and the outer tape in one,

single step during the cable preparation procedure. By eliminating the

need to peel away the tape separately, PCT ’s 1Prep saves valuable time

and money while utilizing current prep tools and procedures.

WIRE®

• Enhanced layer of foil

• Superior shielding performance

• Extends service life

• Dry corrosion protection

• Easy on installers, no messy flooding compounds

• Ensures system reliability

• Eliminate cable prep step

• Reduces prep time

• No additional tools needed

WIRE®

int roduc tion

2

www.pctinternational.com For information regarding specific cables, please visit www.pctinternational.com.© 2007-2010 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

t raining & suppor tAt PCT, the support doesn’t end after the sale, we are here to assist

you every step of the way! We are dedicated to our customers and

are committed to ongoing training and support. Our staff of industry

experienced personnel is here to assist you every step of the way.

individualize d trainingPCT strives to offer each customer a unique training experience that is

designed with their needs in mind. Our technical support personnel

offer onsite training and support to ensure everyone on your team

understands and is confident in our products.

PCT’s internally developed training programs allow our customers

an opportunity to learn through hands-on exercises. These exercises

include the use of PCT products as well as their interoperability with

other industry leading manufacturers’ products.

Completion of the

program assures that

each customer of PCT

is certified on the use

of our products. Each

training program is

tailored to working

with technicians

and management

at their facilities, to

assist them with

training on various

products with an

emphasis on proper

preparation and

installation on both

cable and connectors. Training sessions average around two (2)

hours and accommodate up to 100 trainees per session. Installation

and preparation techniques learned and practiced in these sessions

assists our customers in reducing trouble calls and increasing

subscriber satisfaction.

O ur commitment to you PCT is committed to continued excellence in customer service and

stands behind each and every product we sell to our customers.

hardened drop solutionPCT’s collaborative approach to product development results in

advances that simplify installation and maintenance; improve the

integrity of HFC and fiber infrastructures; reduce truck rolls and

other associated costs; and most importantly - - increase customer

satisfaction and reduce churn. By working closely with customers’

field engineering personnel, PCT produces equipment and

components that straightforwardly address real needs and enable

operators to “Harden the Drop.”

PCT is dedicated to pioneering technologies that are related

to Hardening the Drop. We recognize that most trouble

tickets are derived from the drop or from the consumer’s

home, and while the drop is the least expensive part of

the network to build, it is the most expensive to maintain.

PCT is the first company to engineer, manufacture and deliver a full tap-to-set top box drop portfolio.

It is the cornerstone

of our commitment

to eliminate the drop

as the network’s

weakest link.

E n g i n e e r i n g

resources are directed

to improve this last

link to the customer

through innovations

in such areas as

connector design;

passive equipment

performance; and

coaxial cable quality.

Manufacturing takes

place at three state-of-the-art facilities in the United States and Asia,

ensuring that PCT maintains complete control of product quality.

3

www.pctinternational.com

WIRE®

For information regarding specific cables, please visit www.pctinternational.com.© 2007-2011 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

cable const ruc tiona) center conductor

The center conductor is solid copper-clad steel wire for maximum signal transfer at RF frequencies and excellent strength during installation. The copper is metallurgically bonded to the steel per the requirements of ASTM B 566, Class 10 A.

center conductor adhesive

A proprietary, specially designed adhesive is applied as a coating to the outer surface of the center conductor to keep moisture from the interior of the cable and to sustain overall cable mechanical integrity.

b) foam dielectric

Polyethylene (PE) is foamed to micro-cell structures to achieve the highest level of signal transfer through the cable, while maintaining structural and environmental integrity in the cable.

c) base shield–tape

PCT’s TRITON enhanced base shield tape provides superior shielding performance both before and after flexing.

A laminated aluminum-poly-aluminum tape is fully bonded to the foam dielectric to provide 100 % coverage. Longitudinally applied over the core, the tape minimizes signal leakage.

d) second shield–braid

The second layer of shielding is braided 34 AWG aluminum wire. This important second layer improves shielding and is available in a variety of coverage options.

e) third shield (when specified)

The third layer is similar to the base tape layer, however it is not bonded. This construction provides the enhanced shielding required in harsh environments.

f) fourth shield–braid (when specified)

The fourth layer of shielding is braided 34 AWG aluminum wire. With it, the highest level of protection from signal ingress and egress is achieved.

g) jacket

High quality jacketing is used to protect the cable both from the rigors of installation and the environment. A variety of jacketing materials are available, depending upon the application. For common indoor/outdoor installations, polyvinyl chloride (PVC) jacketing is used and is available in black, white, and neutral colors. For buriable applications, a black or orange polyethylene jacket is used.

PCT’s 1Prep™ rapid preparation technology bonds the cable jacket with the outer tape. This time saving process removes both the jacket and the outer tape in one, single step during the cable preparation procedure.

flooding compounds

Flooding compounds are used between the outer shield and jacket for direct burial or conduit applications. Corrosion Guard™ is used for flooded Series 6 and 11 standard, tri-shield, and quad-shield constructions. Corrosion Guard non-flowing amorphous polypropylene flooding gel protects shield components from corrosion. Corrosion Guard can also be used for aerial installations.

D

A

B

C

E

G

F

WIRE®

4

www.pctinternational.com For information regarding specific cables, please visit www.pctinternational.com.© 2007-2010 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

produc t applications and par t numbersindoor installations

For indoor installations, PVC jacketed cable is available in black, white, and neutral colors to blend well within a customer’s home.

outdoor aerial installations

For standard outdoor aerial plant installations, two PVC jacketed cables are available: aerial and messenger. The aerial cable is designed to be pulled and lashed to a steel strand. Both are easily routed around corners and formed. This cable is also available with Z-WireTM anti-corrosive treatment for added environmental protection.

buried / underground installations

Cables designed to be direct buried or placed in conduit are constructed with a flooding compound between the jacket and outer conductor to protect the cable from corrosion.

RoHS (definition)

Restriction of use of certain Hazardous Substances in electrical and electronic equipment.

connectors and tools

These cables are manufactured for use with industry standard connectors, tools, and all other cable construction-aiding devices.

braided drop cable part numbering system

Description

A MOCSY®7 subscriber access cable

AZ MOCSY®7 subscriber access cable Z-Wire® anti-corrosion protection

H MOCSY®7 TRITON enhanced base shield tape

HZ MOCSY®7 TRITON enhanced base shield tape with Z-Wire® anti-corrosion protection

6 Series 6 braided cable11 Series 11 braided cable59 Series 59 braided cable

60 60 % braid coverage67 67 % braid coverage77 77 % braid coverage90 90 % braid coverage

TS Tri-shield (tape, braid, tape)QS Quad-shield (tape, braid, tape, braid)

HEC Headend, silver coated steel center DL Dual

22 22 AWG twisted pair-BF Bonded foil, PE jacket, flooding compound

-BVM Bonded foil, PVC jacket, messenger wire-BVR Bonded foil, PVC jacket, riser rated-BVV Bonded foil, PVC jacket, UL CATV rated

-BVV1P 1Prep™ rapid preparation technology

-X

Jacketing - black (leave blank)- Series 6: neutral (N), orange (O), white (W)- Series 11: neutral (N), orange (O), white (W)- Series 59: neutral (N), orange (O), white (W)- Series 59 Headend: blue (BL), brown (BN), gray (BY),

green (GR), orange (O), pink (P), red (R), violet (V), white (W), yellow (Y)

Packaging - reel (leave blank)-BOX Packaging - box-CAD Packaging - coil, for reusable caddy-RBX5 Packaging - reel-in box, 500 ft

5

www.pctinternational.com

WIRE®

For information regarding specific cables, please visit www.pctinternational.com.© 2007-2011 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

Series 6 - MOCSY7 75 Ohm Broadband Coaxial CableDrop Cable

Series 6 standard shield 60 % braid 75 ohm

R o H S 2 0 02 /95/ E C c o m p l i a n t - a l l c o n s t r u c t i o n s R e g u l a t o r y C o m p l i a n c ePart Number Description Agency NEC 820 NEC 830A660-BVV black PVC jacket UL/ETL Certification CATV, CM BMAZ660-BVV Z-Wire® UL/ETL Certification CATV, CM BMHZ660-BVV TRITON, Z-Wire® UL/ETL Certification CATV, CM BMA660DL-BVV dual UL/ETL Certification CATV, CM BMA660-BF flooded UL/ETL Certification BMUH660-BF flooded, TRITON UL/ETL Certification BMUA660-BVM messengerAZ660-BVM messenger, Z-Wire®HZ660-BVM messenger, TRITON, Z-Wire ®A660-BVR riser rated UL/ETL Certification CATVR, CMR BMR

Construction MaterialsDielectric Foam PEInner Conductor Copper-clad steel wireOuter Conductor Bonded foil + 60 % aluminum braidMessenger (if applicable) 0.051 in galvanized steel

DimensionsDiameter Over Dielectric 4.490 mm (0.177 in)Diameter Over Jacket 6.860 mm (0.270 in) Diameter Over Tape 4.700 mm (0.185 in)Inner Conductor OD 1.024 mm (0.0403 in)Jacket Wall Thickness 0.760 mm (0.030 in)

Electrical SpecificationsOperating Frequency Band 5 to 1525 MHz Cable Impedance 75 ohm dc Loop Resistance 135.0 ohms/km (41.1 ohms/kft) dc Test Voltage 1500 voltsJacket Spark Test Voltage (rms) 2500 voltsVelocity 85 %Attenuation See page 22

Mechanical Specifications (if applicable)Messenger Breaking Strength 77.1 kgf (170.0 lbf )

Ordering Information (choose one from each column)

6 • 2 • 60

Description

A MOCSY®7 subscriber access cableAZ MOCSY®7 subscriber access cable Z-Wire® anti-corrosion protectionH MOCSY®7 TRITON enhanced base shield tape

HZ MOCSY®7 TRITON enhanced base shield tape with Z-Wire® anti-corrosion protection

6 Series 6 braided cable60 60 % braid coverage

DL Dual-BF Bonded foil, PE jacket, flooding compound

-BVM Bonded foil, PVC jacket, messenger wire-BVR Bonded foil, PVC jacket, riser rated-BVV Bonded foil, PVC jacket, UL CATV rated

-X Jacketing - black (leave blank), neutral (N), orange (O), white (W)Packaging - reel (leave blank)

-BOX Packaging - box-CAD Packaging - coil, for reusable caddy-RBX5 Packaging - reel-in box, 500 ft

6

www.pctinternational.com For information regarding specific cables, please visit www.pctinternational.com.© 2007-2010 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

Series 6 - MOCSY 7 75 O hm Broadband Coa xial CableDrop Cable

Series 6 standard shield 90 % braid 75 ohm

R o H S 2 0 02 /95/ E C c o m p l i a n t - a l l c o n s t r u c t i o n s R e g u l a t o r y C o m p l i a n c ePart Number Description Agency NEC 820 NEC 830A690-BVV black PVC jacket UL/ETL Certification CATV, CM BMA690-BF flooded UL or ETL Certification BMUA690-BVM messenger

Construction MaterialsDielectric Foam PEInner Conductor Copper-clad steel wire Outer Conductor Bonded foil + 90 % aluminum braidMessenger (if applicable) .051 in galvanized steel

DimensionsDiameter Over Dielectric 4.490 mm (0.177 in)Diameter Over Jacket 6.860 mm (0.270 in)Diameter Over Tape 4.700 mm (0.185 in)Inner Conductor OD 1.024 mm (0.040 in)Jacket Wall Thickness 0.760 mm (0.030 in)

Electrical SpecificationsOperating Frequency Band 5 to 1525 MHzCable Impedance 75 ohmdc Loop Resistance 135.0 ohms/km (41.1 ohms/kft)dc Test Voltage 1500Jacket Spark Test Voltage (rms) 2500 voltsVelocity 85 %Attenuation See page 22

Mechanical Specifications (if applicable)Messenger Breaking Strength 77.1 kgf (170.0 lbf )

Ordering Information (choose one from each column)

6 • 2 • 90

Description

A MOCSY®7 subscriber access cable6 Series 6 braided cable

90 90 % braid coverage-BF Bonded foil, PE jacket, flooding compound

-BVM Bonded foil, PVC jacket, messenger wire-BVV Bonded foil, PVC jacket, UL CATV rated

-X Jacketing - black (leave blank), neutral (N), orange (O), white (W)Packaging - reel (leave blank)

-BOX Packaging - box-CAD Packaging - coil, for reusable caddy-RBX5 Packaging - reel-in box, 500 ft

7

www.pctinternational.com

WIRE®

For information regarding specific cables, please visit www.pctinternational.com.© 2007-2011 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

Series 6 - MOCSY 7 75 Ohm Broadband Coaxial CableDrop Cable

Series 6 tri-shield 60 % braid 75 ohm

R o H S 2 0 02 /95/ E C c o m p l i a n t - a l l c o n s t r u c t i o n s R e g u l a t o r y C o m p l i a n c ePart Number Description Agency NEC 820 NEC 830A6TS-BVV black PVC jacket UL/ETL Certification CATV, CM BMA6TS-BVV1P 1 Prep™ UL/ETL Certification CATV, CM BMAZ6TS-BVV Z-Wire® UL/ETL Certification CATV, CM BMHZ6TS-BVV TRITON UL/ETL Certification CATV, CM BMA6TS-BF flooded UL/ETL Certification BMUH6TS-BF flooded, TRITON UL/ETL Certification BMUAZ6TS-BVM messenger, Z-Wire®HZ6TS-BVM messenger, TRITONA6TS-BVR riser rated UL/ETL Certification CATVR, CMR BMR

Construction MaterialsDielectric Foam PEInner Conductor Copper-clad steel wireOuter Conductor Bonded foil + 60 % aluminum braid + non-bonded foilMessenger (if applicable) 0.051 in galvanized steel

DimensionsDiameter Over Dielectric 4.490 mm (0.177 in) Diameter Over Jacket 6.930 mm (0.273 in) Diameter Over Tape 4.700 mm (0.185 in) Inner Conductor OD 1.024 mm (0.0403 in) Jacket Wall Thickness 0.760 mm (0.030 in)

Electrical SpecificationsOperating Frequency Band 5 to 1525 MHz Cable Impedance 75 ohm dc Loop Resistance 126.0 ohms/km (38.4 ohms/kft) dc Test Voltage 1500 voltsJacket Spark Test Voltage (rms) 2500 voltsVelocity 85 %Attenuation See page 22

Mechanical Specifications (if applicable)Messenger Breaking Strength 77.1 kgf (170.0 lbf )

Ordering Information (choose one from each column)

6 • 3 • 60

Description

A MOCSY®7 subscriber access cableAZ MOCSY®7 subscriber access cable Z-Wire® anti-corrosion protectionH MOCSY®7 TRITON enhanced base shield tape

HZ MOCSY®7 TRITON enhanced base shield tape with Z-Wire® anti-corrosion protection

6 Series 6 braided cable60 60 % braid coverage

TS Tri-shield (tape, braid, tape)-BF Bonded foil, PE jacket, flooding compound

-BVM Bonded foil, PVC jacket, messenger wire-BVR Bonded foil, PVC jacket, riser rated-BVV Bonded foil, PVC jacket, UL CATV rated

-BVV1P 1Prep™ rapid preparation technology-X Jacketing - black (leave blank), neutral (N), orange (O), white (W)

Packaging - reel (leave blank)-BOX Packaging - box-CAD Packaging - coil, for reusable caddy-RBX5 Packaging - reel-in box, 500 ft

WIRE®

8

www.pctinternational.com For information regarding specific cables, please visit www.pctinternational.com.© 2007-2010 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

Series 6 - MOCSY 7 75 Ohm Broadband Coaxial CableDrop Cable

Series 6 tri-shield 77 % braid 75 ohm

R o H S 2 0 02 /95/ E C c o m p l i a n t - a l l c o n s t r u c t i o n s R e g u l a t o r y C o m p l i a n c ePart Number Description Agency NEC 820 NEC 830A677TS-BVV black PVC jacket UL/ETL Certification CATV, CM BMA677TS-BVV1P 1Prep™ UL/ETL Certification CATV, CM BMAZ677TS-BVV Z-Wire® UL/ETL Certification CATV, CM BMHZ677TS-BVV TRITON, Z-Wire® UL/ETL Certification CATV, CM BMA677TSDL-BVV dual UL/ETL Certification CATV, CM BMA677TS-BF flooded UL/ETL Certification BMUH677TS-BF flooded, TRITON UL/ETL Certification BMUA677TSDL-BF dual, flooded UL/ETL Certification BMUA677TS-BVM messengerAZ677TS-BVM messenger, Z-Wire®HZ677TS-BVM messenger, TRITON, Z-Wire®A677TS-BVR riser rated UL/ETL Certification CATVR, CMR BMR

Construction MaterialsDielectric Foam PEInner Conductor Copper-clad steel wireOuter Conductor Bonded foil + 77 % aluminum braid + non-bonded foilMessenger (if applicable) 0.051 in galvanized steel

DimensionsDiameter Over Dielectric 4.490 mm (0.177 in) Diameter Over Jacket 6.930 mm (0.273 in) Diameter Over Tape 4.700 mm (0.185 in) Inner Conductor OD 1.024 mm (0.0403 in) Jacket Wall Thickness 0.760 mm (0.030 in)

Electrical SpecificationsOperating Frequency Band 5 to 1525 MHz Cable Impedance 75 ohm dc Loop Resistance 126.0 ohms/km (38.4 ohms/kft) dc Test Voltage 1500 volts Jacket Spark Test Voltage (rms) 2500 voltsVelocity 85 %Attenuation See page 22

Mechanical Specifications (if applicable)Messenger Breaking Strength 77.1 kgf (170.0 lbf )

Ordering Information (choose one from each column)

6 • 3 • 77

Description

A MOCSY®7 subscriber access cableAZ MOCSY®7 subscriber access cable Z-Wire® anti-corrosion protectionH MOCSY®7 TRITON enhanced base shield tape

HZ MOCSY®7 TRITON enhanced base shield tape with Z-Wire® anti-corrosion protection

6 Series 6 braided cable77 77 % braid coverage

TS Tri-shield (tape, braid, tape)TSL Tri-shield (tape, braid, tape), flooded

DL Dual-BF Bonded foil, PE jacket, flooding compound

-BVM Bonded foil, PVC jacket, messenger wire-BVR Bonded foil, PVC jacket, riser rated-BVV Bonded foil, PVC jacket, UL CATV rated

-BVV1P 1Prep™ rapid preparation technology-X Jacketing - black (leave blank), neutral (N), orange (O), white (W)

Packaging - reel (leave blank)-BOX Packaging - box-CAD Packaging - coil, for reusable caddy-RBX5 Packaging - reel-in box, 500 ft

9

www.pctinternational.com

WIRE®

For information regarding specific cables, please visit www.pctinternational.com.© 2007-2011 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

Series 6 - MOCSY 7 75 Ohm Broadband Coaxial CableDrop Cable

Series 6 quad-shield 60 % / 40 % braid 75 ohm

R o H S 2 0 02 /95/ E C c o m p l i a n t - a l l c o n s t r u c t i o n s R e g u l a t o r y C o m p l i a n c ePart Number Description Agency NEC 820 NEC 830A6QS-BVV black PVC jacket UL/ETL Certification CATV, CM BMAZ6QS-BVV Z-Wire® UL/ETL Certification CATV, CM BMA6QS-BF flooded, black PE jacket UL/ETL Certification BMUA6QS-BVM messengerAZ6QS-BVM messenger, Z-Wire® A6QS-BVR riser rated UL/ETL Certification CATVR, CMR BMR

Construction MaterialsDielectric Foam PEInner Conductor Copper-clad steel wireOuter Conductor Bonded foil + 60 % aluminum braid + non-bonded foil + 40 % aluminum braidMessenger (if applicable) 0.051 in galvanized steel

DimensionsDiameter Over Dielectric 4.490 mm (0.177 in) Diameter Over Jacket 7.490 mm (0.295 in) Diameter Over Tape 4.700 mm (0.185 in) Inner Conductor OD 1.024 mm (0.0403 in) Jacket Wall Thickness 0.760 mm (0.030 in)

Electrical SpecificationsOperating Frequency Band 5 to 1525 MHz Cable Impedance 75 ohm dc Loop Resistance 121.0 ohms/km (36.9 ohms/kft) dc Test Voltage 1500 voltsJacket Spark Test Voltage (rms) 2500 voltsVelocity 85 %Attenuation See page 22

Mechanical Specifications (if applicable)Messenger Breaking Strength 77.1 kgf (170.0 lbf )

Ordering Information (choose one from each column)

6 • 4 • 60/40

Description

A MOCSY®7 subscriber access cableAZ MOCSY®7 subscriber access cable Z-Wire® anti-corrosion protection

6 Series 6 braided cableQS Quad-shield (tape, braid, tape, braid)

-BF Bonded foil, PE jacket, flooding compound-BVM Bonded foil, PVC jacket, messenger wire-BVR Bonded foil, PVC jacket, riser rated-BVV Bonded foil, PVC jacket, UL CATV rated

-X Jacketing - black (leave blank), neutral (N), orange (O), white (W)Packaging - reel (leave blank)

-BOX Packaging - box-CAD Packaging - coil, for reusable caddy-RBX5 Packaging - reel-in box, 500 ft

WIRE®

10

www.pctinternational.com For information regarding specific cables, please visit www.pctinternational.com.© 2007-2010 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

Series 11 - MOCSY 7 75 Ohm Broadband Coaxial CableDrop Cable

Series 11 standard shield 60 % braid 75 ohm

R o H S 2 0 02 /95/ E C c o m p l i a n t - a l l c o n s t r u c t i o n s R e g u l a t o r y C o m p l i a n c ePart Number Description Agency NEC 820 NEC 830A1160-BVV black PVC jacket UL/ETL Certification CATV, CM BMA1160-BF flooded, UL/ETL Certification BMUA1160-BVM messengerAZ1160-BVM messenger, Z-Wire®

Construction MaterialsDielectric Foam PEInner Conductor Copper-clad steel wireOuter Conductor Bonded foil + 60 % aluminum braidMessenger (if applicable) 0.072 in galvanized steel

DimensionsDiameter Over Dielectric 7.110 mm (0.280 in) Diameter Over Jacket 10.160 mm (0.400 in) Diameter Over Tape 7.320 mm (0.288 in) Inner Conductor OD 1.630 mm (0.064 in) Jacket Wall Thickness 1.090 mm (0.043 in)

Electrical SpecificationsOperating Frequency Band 5 to 1525 MHz Cable Impedance 75 ohm dc Loop Resistance 65.6 ohms/km (20.0 ohms/kft) dc Test Voltage 1500 voltsJacket Spark Test Voltage (rms) 2500 voltsVelocity 85 %Attenuation See page 22

Mechanical Specifications (if applicable)Messenger Breaking Strength 156.9 kgf (346.0 lbf )

Ordering Information (choose one from each column)

11 • 2 • 60

Description

A MOCSY®7 subscriber access cableAZ MOCSY®7 subscriber access cable Z-Wire® anti-corrosion protection

11 Series 11 braided cable60 60 % braid coverage

-BF Bonded foil, PE jacket, flooding compound-BVM Bonded foil, PVC jacket, messenger wire-BVV Bonded foil, PVC jacket, UL CATV rated

-X Jacketing - black (leave blank)neutral (N), orange (O), white (W)Packaging - reel (leave blank)

-BOX Packaging - box-CAD Packaging - coil, for reusable caddy-RBX5 Packaging - reel-in box, 500 ft

11

www.pctinternational.comFor information regarding specific cables, please visit www.pctinternational.com.© 2007-2011 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

Series 11 - MOCSY 7 75 Ohm Broadband Coaxial CableDrop Cable

Series 11 standard shield 90 % braid 75 ohm

R o H S 2 0 02 /95/ E C c o m p l i a n t - a l l c o n s t r u c t i o n s R e g u l a t o r y C o m p l i a n c ePart Number Description Agency NEC 820 NEC 830A1190-BVV black PVC jacket UL/ETL Certification CATV, CM BMA1190-BF flooded UL/ETL Certification BMUA1190-BVM messenger

Construction MaterialsDielectric Foam PEInner Conductor Copper-clad steel wireOuter Conductor Bonded foil + 90 % aluminum braidMessenger (if applicable) 0.072 in galvanized steel

DimensionsDiameter Over Dielectric 7.110 mm (0.280 in)Diameter Over Jacket 10.160 mm (0.400 in)Diameter Over Tape 7.320 mm (0.288 in)Inner Conductor OD 1.630 mm (0.064 in)Jacket Wall Thickness 1.090 mm (0.043 in)

Electrical SpecificationsOperating Frequency Band 5 to 1525 MHzCable Impedance 75 ohmdc Loop Resistance 65.6 ohms/km (20.0 ohms/kft)dc Test Voltage 1500 voltsJacket Spark Test Voltage (rms) 2500 voltsVelocity 85 %Attenuation See page 22

Mechanical Specifications (if applicable)Messenger Breaking Strength 156.9 kgf (346.0 lbf )

Ordering Information (choose one from each column)

11 • 2 • 90

Description

A MOCSY®7 subscriber access cable11 Series 11 braided cable

90 90 % braid coverage-BF Bonded foil, PE jacket, flooding compound

-BVM Bonded foil, PVC jacket, messenger wire-BVV Bonded foil, PVC jacket, UL CATV rated

-X Jacketing - black (leave blank), neutral (N), orange (O), white (W)Packaging - reel (leave blank)

-BOX Packaging - box

-CAD Packaging - coil, for reusable caddy

-RBX5 Packaging - reel-in box, 500 ft

WIRE®

12

www.pctinternational.com For information regarding specific cables, please visit www.pctinternational.com.© 2007-2010 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

Series 11 - MOCSY 7 75 Ohm Broadband Coaxial CableDrop Cable

Series 11 tri-shield 60 % braid 75 ohm

R o H S 2 0 02 /95/ E C c o m p l i a n t - a l l c o n s t r u c t i o n s R e g u l a t o r y C o m p l i a n c ePart Number Description Agency NEC 820 NEC 830A11TS-BVV black PVC jacket UL/ETL Certification CATV, CM BMAZ11TS-BVV Z-Wire® UL/ETL Certification CATV, CM BMA11TS-BF flooded UL/ETL Certification BMUA11TS-BVM messengerAZ11TS-BVM messenger, Z-Wire®

Construction MaterialsDielectric Foam PEInner Conductor Copper-clad steel wireOuter Conductor Bonded foil + 60 % aluminum braid + non-bonded foil Messenger (if applicable) 0.072 in galvanized steel

DimensionsDiameter Over Dielectric 7.110 mm (0.280 in)Diameter Over Jacket 10.160 mm (0.400 in)Diameter Over Tape 7.320 mm (0.288 in)Inner Conductor OD 1.630 mm (0.064 in)Jacket Wall Thickness 1.070 mm (0.042 in)

Electrical SpecificationsOperating Frequency Band 5 to 1525 MHzCable Impedance 75 ohmdc Loop Resistance 57.1 ohms/km (17.4 ohms/kft)dc Test Voltage 1500 voltsJacket Spark Test Voltage (rms) 2500 voltsVelocity 85 %Attenuation See page 22

Mechanical Specifications (if applicable)Messenger Breaking Strength, 156.9 kgf (346.0 Ibf )

Ordering Information (choose one from each column)

11 • 3 • 60

Description

A MOCSY®7 subscriber access cableAZ MOCSY®7 subscriber access cable Z-Wire® anti-corrosion protection

11 Series 11 braided cable60 60 % braid coverage

TS Tri-shield (tape, braid, tape)-BF Bonded foil, PE jacket, flooding compound

-BVM Bonded foil, PVC jacket, messenger wire-BVV Bonded foil, PVC jacket, UL CATV rated

-X Jacketing - black (leave blank), neutral (N), orange (O), white (W)Packaging - reel (leave blank)

-BOX Packaging - box-CAD Packaging - coil, for reusable caddy-RBX5 Packaging - reel-in box, 500 ft

13

www.pctinternational.comFor information regarding specific cables, please visit www.pctinternational.com.© 2007-2011 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

Series 11 - MOCSY 7 75 Ohm Broadband Coaxial CableDrop Cable

Series 11 tri-shield 77 % braid 75 ohm

R o H S 2 0 02 /95/ E C c o m p l i a n t - a l l c o n s t r u c t i o n s R e g u l a t o r y C o m p l i a n c ePart Number Description Agency NEC 820 NEC 830A1177TS-BVV black PVC jacket UL/ETL Certification CATV, CM BMA1177TS-BF flooded UL/ETL Certification BMUA1177TS-BVM messenger

Construction MaterialsDielectric Foam PEInner Conductor Copper-clad steel wireOuter Conductor Bonded foil + 77 % aluminum braid + non-bonded foilMessenger (if applicable) 0.072 in galvanized steel

DimensionsDiameter Over Dielectric 7.110 mm (0.280 in)Diameter Over Jacket 10.160 mm (0.400 in)Diameter Over Tape 7.320 mm (0.288 in)Inner Conductor OD 1.630 mm (0.064 in)Jacket Wall Thickness 1.070 mm (0.042 in)

Electrical SpecificationsOperating Frequency Band 5 to 1525 MHz Cable Impedance 75 ohm dc Loop Resistance 57.1 ohms/km (17.4 ohms/kft) dc Test Voltage 1500 voltsJacket Spark Test Voltage (rms) 2500 voltsVelocity 85 %Attenuation See page 22

Mechanical Specifications (if applicable)Messenger Breaking Strength 156.9 kgf (346.0 Ibf )

Ordering Information (choose one from each column)

11 • 3 • 77

Description

A MOCSY®7 subscriber access cable11 Series 11 braided cable

77 77 % braid coverageTS Tri-shield (tape, braid, tape)

-BF Bonded foil, PE jacket, flooding compound-BVM Bonded foil, PVC jacket, messenger wire-BVV Bonded foil, PVC jacket, UL CATV rated

-X Jacketing - black (leave blank), neutral (N), orange (O), white (W)Packaging - reel (leave blank)

-BOX Packaging - box-CAD Packaging - coil, for reusable caddy-RBX5 Packaging - reel-in box, 500 ft

WIRE®

14

www.pctinternational.com For information regarding specific cables, please visit www.pctinternational.com.© 2007-2010 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

Series 11 - MOCSY 7 75 Ohm Broadband Coaxial CableDrop Cable

Series 11 quad-shield 60 % / 40 % braid 75 ohm

R o H S 2 0 02 /95/ E C c o m p l i a n t - a l l c o n s t r u c t i o n s R e g u l a t o r y C o m p l i a n c ePart Number Description Agency NEC 820 NEC 830A11QS-BVV black PVC jacket UL/ETL Certification CATV, CM BMAZ11QS-BVV Z-Wire® UL/ETL Certification CATV, CM BMA11QS-BF flooded UL/ETL Certification BMUA11QS-BVM messengerA11QS-BVR riser rated UL/ETL Certification CATVR, CMR BMR

Construction MaterialsDielectric Foam PEInner Conductor Copper-clad steel wireOuter Conductor Bonded foil + 60 % aluminum braid + non-bonded foil + 40 % aluminum braidMessenger (if applicable) 0.072 in galvanized steel

DimensionsDiameter Over Dielectric 7.110 mm (0.280 in)Diameter Over Jacket 10.290 mm (0.405 in)Diameter Over Tape 7.320 mm (0.288 in)Inner Conductor OD 1.630 mm (0.064 in)Jacket Wall Thickness 0.940 mm (0.037 in)

Electrical SpecificationsOperating Frequency Band 5 to 1525 MHzCable Impedance 75 ohmdc Loop Resistance 54.8 ohms/km (16.7 ohms/kft)dc Test Voltage 1500 voltsJacket Spark Test Voltage (rms) 2500 voltsVelocity 85 %Attenuation See page 22

Mechanical Specifications (if applicable)Messenger Breaking Strength 156.9 kgf (346.0 lbf )

Ordering Information (choose one from each column)

11 • 4 • 60/40

Description

A MOCSY®7 subscriber access cableAZ MOCSY®7 subscriber access cable Z-Wire® anti-corrosion protection

11 Series 11 braided cableQS Quad-shield (tape, braid, tape, braid)

-BF Bonded foil, PE jacket, flooding compound-BVM Bonded foil, PVC jacket, messenger wire-BVR Bonded foil, PVC jacket, riser rated-BVV Bonded foil, PVC jacket, UL CATV rated

-X Jacketing - black (leave blank), neutral (N), orange (O), white (W)Packaging - reel (leave blank)

-BOX Packaging - box-CAD Packaging - coil, for reusable caddy-RBX5 Packaging - reel-in box, 500 ft

15

www.pctinternational.comFor information regarding specific cables, please visit www.pctinternational.com.© 2007-2011 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

Series 59 - MOCSY 7 75 Ohm Broadband Coaxial CableDrop Cable

Series 59 standard shield 67 % braid 75 ohm

R o H S 2 0 02 /95/ E C c o m p l i a n t - a l l c o n s t r u c t i o n s R e g u l a t o r y C o m p l i a n c ePart Number Description Agency NEC 820 NEC 830A5967-BVV black PVC jacket UL/ETL Certification CATV, CM BMA5967-BF flooded UL/ETL Certification BMUA5967-BVM messenger

Construction MaterialsDielectric Foam PEInner Conductor Copper-clad steel wireOuter Conductor Bonded foil + 67 % aluminum braidMessenger (if applicable) 0.051 in galvanized steel

DimensionsDiameter Over Dielectric 3.660 mm (0.144 in)Diameter Over Jacket 6.100 mm (0.240 in)Diameter Over Tape 3.860 mm (0.152 in)Inner Conductor OD 0.810 mm (0.032 in)Jacket Wall Thickness 0.790 mm (0.031 in)Messenger Diameter 1.300 mm (0.051 in)

Electrical SpecificationsOperating Frequency Band 5 to 1525 MHzCable Impedance 75 ohmdc Loop Resistance 200.0 ohms/km (60.9 ohms/kft)dc Test Voltage 1500 voltsJacket Spark Test Voltage (rms) 2500 voltsVelocity 85 %Attenuation See page 22

Mechanical SpecificationsMessenger Breaking Strength 77.1 kgf (170.0 lbf )

Ordering Information (choose one from each column)

59 • 2 • 67

Description

A MOCSY®7 subscriber access cable59 Series 59 braided cable

67 67 % braid coverage-BF Bonded foil, PE jacket, flooding compound

-BVM Bonded foil, PVC jacket, messenger wire-BVV Bonded foil, PVC jacket, UL CATV rated

-X Jacketing - black (leave blank), neutral (N), orange (O), white (W)Packaging - reel (leave blank)

-BOX Packaging - box-CAD Packaging - coil, for reusable caddy-RBX5 Packaging - reel-in box, 500 ft

16

www.pctinternational.com For information regarding specific cables, please visit www.pctinternational.com.© 2007-2010 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

Series 59 - MOCSY 7 75 Ohm Broadband Coaxial CableDrop Cable

Series 59 tri-shield 67 % braid 75 ohm

R o H S 2 0 02 /95/ E C c o m p l i a n t - a l l c o n s t r u c t i o n s R e g u l a t o r y C o m p l i a n c ePart Number Description Agency NEC 820 NEC 830A59TS-BVV black PVC jacket UL/ETL Certification CATV, CM BMA59TS-BVM messenger

Construction MaterialsDielectric Foam PEInner Conductor Copper-clad steel wireOuter Conductor Bonded foil + 67 % aluminum braid + non-bonded foilMessenger (if applicable) 0.051 in galvanized steel

Dimensions Diameter Over Dielectric 3.660 mm (0.144 in)Diameter Over Jacket 6.200 mm (0.244 in)Diameter Over Tape 3.860 mm (0.152 in)Inner Conductor OD 0.810 mm (0.032 in)Jacket Wall Thickness 0.760 mm (0.030 in)Messenger Diameter 1.300 mm (0.051 in)

Electrical SpecificationsOperating Frequency Band 5 to 1525 MHzCable Impedance 75 ohmdc Loop Resistance 190.0 ohms/km (58.0 ohms/kft)dc Test Voltage 1500 voltsJacket Spark Test Voltage (rms) 2500 voltsVelocity 85 %Attenuation See page 22

Mechanical SpecificationsMessenger Breaking Strength 77.1 kgf (170.0 lbf )

Ordering Information (choose one from each column)

59 • 3 • 67

Description

A MOCSY®7 subscriber access cable59 Series 59 braided cable

TS Tri-shield (tape, braid, tape)-BVM Bonded foil, PVC jacket, messenger wire-BVV Bonded foil, PVC jacket, UL CATV rated

-X Jacketing - black (leave blank), neutral (N), orange (O), white (W)Packaging - reel (leave blank)

-BOX Packaging - box-CAD Packaging - coil, for reusable caddy-RBX5 Packaging - reel-in box, 500 ft

17

www.pctinternational.comFor information regarding specific cables, please visit www.pctinternational.com.© 2007-2011 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

Series 59 - MOCSY 7 75 Ohm Broadband Coaxial CableDrop Cable

Series 59 quad-shield 53 % / 35 % braid 75 ohm

R o H S 2 0 02 /95/ E C c o m p l i a n t - a l l c o n s t r u c t i o n s R e g u l a t o r y C o m p l i a n c ePart Number Description Agency NEC 820 NEC 830A59QS-BVV black PVC jacket UL/ETL Certification CATV, CM BM

Construction MaterialsDielectric Foam PEInner Conductor Copper-clad steel wireOuter Conductor Bonded foil + 53 % aluminum braid + non-bonded foil + 35 % aluminum braid

DimensionsDiameter Over Dielectric 3.660 mm (0.144 in)Diameter Over Jacket 6.730 mm (0.265 in)Diameter Over Tape 3.860 mm (0.152 in)Inner Conductor OD 0.810 mm (0.032 in)Jacket Wall Thickness 0.760 mm (0.030 in)

Electrical SpecificationsOperating Frequency Band 5 to 1525 MHzCable Impedance 75 ohmdc Loop Resistance 184.0 ohms/km (56.1 ohms/kft)dc Test Voltage 1500 voltsJacket Spark Test Voltage (rms) 2500 voltsVelocity 85 %Attenuation See page 22

Ordering Information (choose one from each column)

59 • 4 • 53/35

Description

A MOCSY®7 subscriber access cable59 Series 59 braided cable

QS Quad-shield (tape, braid, tape, braid)-BVV Bonded foil, PVC jacket, UL CATV rated

-X Jacketing - black (leave blank), neutral (N), orange (O), white (W)Packaging - reel (leave blank)

-BOX Packaging - box-CAD Packaging - coil, for reusable caddy-RBX5 Packaging - reel-in box, 500 ft

18

www.pctinternational.com For information regarding specific cables, please visit www.pctinternational.com.© 2007-2010 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

Series 59- MOCSY 7 75 Ohm Broadband Coaxial CableHeadend Cable

Series 59 quad-shield 95 % / 95 % braid 75 ohm

R o H S 2 0 02 /95/ E C c o m p l i a n t - a l l c o n s t r u c t i o n s R e g u l a t o r y C o m p l i a n c ePart Number Description Agency NEC 820 NEC 830A5995-HEC black PVC jacket, UL/ETL Certification CATV, CM BM silver coated steel center conductor

Construction MaterialsDielectric Foam PEInner Conductor Silver-plated copper-clad steel wireOuter Conductor Bonded foil + 95 % aluminum braid + non-bonded foil + 95 % aluminum braid

DimensionsDiameter Over Dielectric 3.661 mm (0.142 in)Diameter Over Jacket 6.860 mm (0.270 in)Diameter Over Tape 3.810 mm (0.150 in)Inner Conductor OD 0.810 mm (0.032 in)Jacket Wall Thickness 0.760 mm (0.030 in)

Electrical SpecificationsOperating Frequency Band 5 to 1525 MHz Cable Impedance 75 ohm dc Loop Resistance 184.0 ohms/km (56.1 ohms/kft) dc Test Voltage 1500 voltsJacket Spark Test Voltage (rms) 2500 voltsVelocity 85 %Attenuation See page 22

Ordering Information (choose one from each column)

59 • 4 • 95/95

Description

A MOCSY®7 subscriber access cable59 Series 59 braided cable

95 95 % / 95 % braid coverageHEC Headend, silver coated steel center

-X Jacketing - black (leave blank), blue (BL), brown (BN), gray (GY), green (GR), orange (O), pink (P), red (R), violet (V), white (W), yellow (Y)

Packaging - reel (leave blank)-BOX Packaging - box-CAD Packaging - coil, for reusable caddy-RBX5 Packaging - reel-in box, 500 ft

19

www.pctinternational.com

WIRE®

For information regarding specific cables, please visit www.pctinternational.com.© 2007-2011 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

Series 6 - MOCSY 7 75 Ohm Broadband Coaxial CableHybrid Coax / Twisted Pair

Series 6 tri-shield 60 % braid 75 ohm 22 AWG twisted pair

R o H S 2 0 02 /95/ E C c o m p l i a n t - a l l c o n s t r u c t i o n s R e g u l a t o r y C o m p l i a n c ePart Number Description Agency NEC 820 NEC 830A6TS22-BVV black PVC jacket UL/ETL Certification CATV, CM BMA6TS22-BF flooded UL/ETL Certification BMUA6TS22-BVM messengerAZ6TS22-BVM messenger, Z-Wire®

Construction MaterialsCoax Dielectric Foam PECoax Inner Conductor Copper-clad steel wireCoax Outer Conductor Bonded foil + 60 % aluminum braid + non-bonded foilPair Dielectric Solid PEPair Conductor Solid 22 AWG CopperMessenger (if applicable) .051 in galvanized steel

Coax DimensionsDiameter Over Dielectric 4.490 mm (0.177 in)Diameter Over Jacket 6.930 mm (0.273 in)Diameter Over Tape 4.700 mm (0.185 in)Inner Conductor OD 1.024 mm (0.040 in)Jacket Wall Thickness 0.760 mm (0.030 in)

Coax Electrical SpecificationsOperating Frequency Band 5 to 1525 MHzCable Impedance 75 ohmdc Loop Resistance 126.0 ohms/km (38.4 ohms/kft)dc Test Voltage 1500 voltsJacket Spark Test Voltage (rms) 2500 voltsVelocity 85 %Attenuation See page 22

Mechanical Specifications (if applicable)Messenger Breaking Strength 77.1 kgf (170.0 lbf )

Ordering Information (choose one from each column)

6 • 3 • 60 • 22

Description

A MOCSY®7 subscriber access cableAZ MOCSY®7 subscriber access cable Z-Wire® anti-corrosion protection

6 Series 6 braided cableTS Tri-shield (tape, braid, tape)

22 22 AWG twisted pair-BF Bonded foil, PE jacket, flooding compound

-BVM Bonded foil, PVC jacket, messenger wire-BVV Bonded foil, PVC jacket, UL CATV rated

-BVV1P 1Prep™ rapid preparation technology-X Jacketing - black (leave blank), neutral (N), orange (O), white (W)

Packaging - reel (leave blank)

WIRE®

20

www.pctinternational.com For information regarding specific cables, please visit www.pctinternational.com.© 2007-2010 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

Series 6 - MOCSY 7 75 Ohm Broadband Coaxial Cable Hybrid Coax / Twisted Pair

Series 6 quad-shield 60 % / 40 % braid 75 ohm 22 AWG twisted pair

R o H S 2 0 02 /95/ E C c o m p l i a n t - a l l c o n s t r u c t i o n s R e g u l a t o r y C o m p l i a n c ePart Number Description Agency NEC 820 NEC 830A6QS22-BVV black PVC jacket UL/ETL Certification CATV, CM BMA6QS22-BF flooded UL/ETL Certification BMUA6TS22-BVM messengerAZ6QS22-BVM messenger, Z-Wire®

Construction MaterialsCoax Dielectric Foam PECoax Inner Conductor Copper-clad steel wireCoax Outer Conductor Bonded foil + 60 % aluminum braid + non-bonded foil + 40 % aluminum braidPair Dielectric Solid PEPair Conductor Solid 22 AWG CopperMessenger (if applicable) .051 in galvanized steel

Coax DimensionsDiameter Over Dielectric 4.490 mm (0.177 in)Diameter Over Jacket 7.490 mm (0.295 in)Diameter Over Tape 4.700 mm (0.185 in)Inner Conductor OD 1.024 mm (0.040 in)Jacket Wall Thickness 0.760 mm (0.030 in)

Coax Electrical SpecificationsOperating Frequency Band 5 to 1525 MHzCable Impedance 75 ohmdc Loop Resistance 121.0 ohms/km (36.9 (ohms/kft)) dc Test Voltage 1500 voltsJacket Spark Test Voltage (rms) 2500 volts Velocity 85 %Attenuation See page 22

Mechanical Specifications (if applicable)Messenger Breaking Strength 77.1 kgf (170.0 lbf )

Ordering Information (choose one from each column)

6 • 4 • 60/40 • 22

Description

A MOCSY®7 subscriber access cableAZ MOCSY®7 subscriber access cable Z-Wire® anti-corrosion protection

6 Series 6 braided cableTS Tri-shield (tape, braid, tape)QS Quad-shield (tape, braid, tape, braid)

22 22 AWG twisted pair-BF Bonded foil, PE jacket, flooding compound

-BVM Bonded foil, PVC jacket, messenger wire-BVR Bonded foil, PVC jacket, riser rated-BVV Bonded foil, PVC jacket, UL CATV rated

-X Jacketing - black (leave blank), neutral (N), orange (O), white (W)Packaging - reel (leave blank)

21

www.pctinternational.comFor information regarding specific cables, please visit www.pctinternational.com.© 2007-2011 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

WIRE®

Series 11 - MOCSY 7 75 Ohm Broadband Coaxial Cable Hybrid Coax / Twisted Pair

Series 11 tri-shield 60 % braid 75 ohm 22 AWG twisted pair

R o H S 2 0 02 /95/ E C c o m p l i a n t - a l l c o n s t r u c t i o n s R e g u l a t o r y C o m p l i a n c ePart Number Description Agency NEC 820 NEC 830A11TS22-BVV black PVC jacket UL/ETL Certification CATV, CM BMA11TS22-BF flooded UL/ETL Certification BMUA11TS22-BVM messengerAZ11TS22-BVM messenger, Z-Wire®

Construction MaterialsCoax Dielectric Foam PECoax Inner Conductor Copper-clad steel wireCoax Outer Conductor Bonded foil + 60 % aluminum braid + non-bonded foil Pair Dielectric Solid PEPair Conductor Solid 22 AWG CopperMessenger (if applicable) .072 in galvanized steel

Coax Dimensions Diameter Over Dielectric 7.110 mm (0.280 in)Diameter Over Jacket 10.160 mm (0.400 in)Diameter Over Tape 7.320 mm (0.288 in)Inner Conductor OD 1.630 mm (0.064 in)Jacket Wall Thickness 1.070 mm (0.042 in)

Coax Electrical SpecificationsOperating Frequency Band 5 to 1525 MHzCable Impedance 75 ohmdc Loop Resistance 57.1 ohms/km (17.4 ohms/kft) dc Test Voltage 1500 voltsJacket Spark Test Voltage (rms) 2500 voltsVelocity 85 %Attenuation See page 22

Mechanical Specifications (if applicable)Messenger Breaking Strength 156.9 kgf (346.0 lbf )

Ordering Information (choose one from each column)

11 • 3 • 60 • 22

Description

A MOCSY®7 subscriber access cableAZ MOCSY®7 subscriber access cable Z-Wire® anti-corrosion protection

11 Series 11 braided cableTS Tri-shield (tape, braid, tape)

22 22 AWG twisted pair-BF Bonded foil, PE jacket, flooding compound

-BVM Bonded foil, PVC jacket, messenger wire-BVV Bonded foil, PVC jacket, UL CATV rated

-X Jacketing - black (leave blank), neutral (N), orange (O), white (W)Packaging - reel (leave blank)

WIRE®

22

www.pctinternational.com For information regarding specific cables, please visit www.pctinternational.com.© 2007-2010 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

E xpande d f re quencies for a l l ser ies ref le c tp er formance for M o C A .

attenuation tables

Series 6(applicable to all cable in this series of drop cable category)

Frequency MHz

Attenuation dB/100 m

Attenuation dB/100 ft

5 1.90 0.5855 5.25 1.60

211 10.00 3.05250 10.82 3.30270 11.04 3.37300 11.64 3.55330 12.26 3.74350 12.63 3.85400 13.61 4.15450 14.43 4.40500 15.29 4.66550 16.08 4.90600 16.73 5.10750 18.54 5.65870 20.04 6.11

1000 21.49 6.551125 22.80 6.951525 26.54 8.09

Series 11(applicable to all cable in this series of drop cable category)

Frequency MHz

Attenuation dB/100 m

Attenuation dB/100 ft

5 1.25 0.3855 3.15 0.96

211 6.23 1.90250 6.72 2.50270 7.00 2.13300 7.38 2.25330 7.71 2.35350 7.94 2.42400 8.53 2.60450 9.02 2.75500 9.51 2.90550 9.97 3.04600 10.43 3.18750 11.97 3.65870 13.31 4.06

1000 14.27 4.351125 15.14 4.611525 17.62 5.37

Series 59(applicable to all cable in this series of drop cable category)

Frequency MHz

Attenuation dB/100 m

Attenuation dB/100 ft

5 2.82 0.8655 6.73 2.05

211 12.47 3.80250 13.45 4.10270 13.85 4.22300 14.60 4.45330 15.29 4.66350 15.75 4.80400 16.73 5.10450 17.72 5.40500 18.70 5.70550 19.52 5.95600 20.35 6.20750 22.87 6.97870 24.85 7.57

1000 26.64 8.121125 28.26 8.611525 32.90 10.03

23

www.pctinternational.com

WIRE®

For information regarding specific cables, please visit www.pctinternational.com.© 2007-2011 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

Packing/Shipping Details Reel Packaging

Part Number Cable Length Reel Flange Reel HubReel

Traverse Total WeightReels Per

Pallet m (ft) cm (in) cm (in) cm (in) kg (lb)

Series 6A660-BVV 305 (1000) 31.0 (12.0) 12.5 (4.9) 30.0 (11.8) 14.5 (32.0) 36

AZ660-BVV 305 (1000) 31.0 (12.0) 12.5 (4.9) 30.0 (11.8) 14.5 (32.0) 36

A660DL-BVV 305 (1000) 50.0 (20.0) 20.0 (7.9) 30.0 (11.8) 29.0 (64.0) 12

A660-BF 305 (1000) 31.0 (12.0) 12.5 (4.9) 30.0 (11.8) 11.8 (26.0) 36

A660-BVM 305 (1000) 36.0 (14.0) 12.5 (4.9) 30.0 (11.8) 18.0 (40.0) 27

AZ660-BVM 305 (1000) 36.0 (14.0) 12.5 (4.9) 30.0 (11.8) 18.0 (40.0) 27

A660-BVR 305 (1000) 31.0 (12.0) 12.5 (4.9) 30.0 (11.8) 14.5 (32.0) 36

A690-BVV 305 (1000) 31.0 (12.0) 12.5 (4.9) 30.0 (11.8) 14.5 (32.0) 36

A690-BF 305 (1000) 31.0 (12.0) 12.5 (4.9) 30.0 (11.8) 13.2 (29.0) 36

A690-BVM 305 (1000) 36.0 (14.0) 12.5 (4.9) 30.0 (11.8) 18.0 (40.0) 27

A6TS-BVV 305 (1000) 31.0 (12.0) 12.5 (4.9) 30.0 (11.8) 14.5 (32.0) 36

A6TS-BVV1P 305 (1000) 31.0 (12.0) 12.5 (4.9) 30.0 (11.8) 14.5 (32.0) 36

AZ6TS-BVV 305 (1000) 31.0 (12.0) 12.5 (4.9) 30.0 (11.8) 14.5 (32.0) 36

A6TS-BF 305 (1000) 31.0 (12.0) 12.5 (4.9) 30.0 (11.8) 12.0 (26.0) 36

A6TS-BVM 305 (1000) 36.0 (14.0) 12.5 (4.9) 30.0 (11.8) 18.0 (40.0) 27

AZ6TS-BVM 305 (1000) 36.0 (14.0) 12.5 (4.9) 30.0 (11.8) 18.0 (40.0) 27

A6TS-BVR 305 (1000) 31.0 (12.0) 12.5 (4.9) 30.0 (11.8) 14.5 (32.0) 36

A677TS-BVV 305 (1000) 31.0 (12.0) 12.5 (4.9) 30.0 (11.8) 14.5 (32.0) 36

A677TS-BVV1P 305 (1000) 31.0 (12.0) 12.5 (4.9) 30.0 (11.8) 14.5 (32.0) 36

A677TSDL-BVV 305 (1000) 31.0 (12.0) 12.5 (4.9) 30.0 (11.8) 14.5 (32.0) 12

A677TS-BF 305 (1000) 31.0 (12.0) 12.5 (4.9) 30.0 (11.8) 12.0 (26.0) 36

A677TSL-BF 305 (1000) 50.0 (19.7) 20.0 (7.9) 30.0 (11.8) 23.4 (51.6) 12

A677TS-BVM 305 (1000) 31.0 (14.0) 12.5 (4.9) 30.0 (11.8) 18.0 (40.0) 27

AZ677TS-BVM 305 (1000) 35.5 (14.0) 12.5 (4.9) 30.0 (11.8) 14.5 (32.0) 27

A677TS-BVR 305 (1000) 31.0 (12.0) 12.5 (4.9) 30.0 (11.8) 14.5 (32.0) 36

A6QS-BVV 305 (1000) 34.0 (14.0) 12.5 (4.9) 30.0 (11.8) 17.5 (39.0) 27

AZ6QS-BVV 305 (1000) 34.0 (14.0) 12.5 (4.9) 30.0 (11.8) 17.5 (39.0) 27

A6QS-BF 305 (1000) 31.0 (14.0) 12.5 (4.9) 30.0 (11.8) 14.5 (32.0) 27

A6QS-BVM 305 (1000) 40.0 (16.0) 12.5 (4.9) 30.0 (11.8) 22.8 (50.0) 18

AZ6QS-BVM 305 (1000) 40.0 (16.0) 12.5 (4.9) 30.0 (11.8) 22.8 (50.0) 18

A6QS-BVR 305 (1000) 35.5 (14.0) 12.5 (4.9) 30.0 (11.8) 17.5 (39.0) 27

A6TS22-BVV 305 (1000) 40.0 (16.0) 12.5 (4.9) 30.0 (11.8) 45.5 (100.1) 18

A6TS22-BF 305 (1000) 40.0 (16.0) 12.5 (4.9) 30.0 (11.8) 45.5 (100.1) 18

A6TS22-BVM 305 (1000) 46.0 (18.1) 12.5 (4.9) 30.0 (11.8) 26.4 (58.1) 12

AZ6TS22-BVM 305 (1000) 46.0 (18.1) 12.5 (4.9) 30.0 (11.8) 26.4 (58.1) 12

A6QS22-BVV 305 (1000)

A6QS22-BF 305 (1000) 46.0 (18.1) 12.5 (4.9) 30.0 (11.8) 16.6 (36.5) 12

A6QS22-BVM 305 (1000)

AZ6QS22-BVM 305 (1000) 50.0 (19.7) 20.0 (7.9) 30.0 (11.8) 30.0 (66.0) 12

For information regarding specific cables, please visit www.pctinternational.com.© 2007-2010 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

24

www.pctinternational.com

Packing/Shipping Details Reel Packaging

Part Number Cable Length Reel Flange Reel HubReel

Traverse Total WeightReels Per

Pallet m (ft) cm (in) cm (in) cm (in) kg (lb)

Series 11A1160-BVV 305 (1000) 46.0 (18.0) 20.0 (7.9) 30.0 (11.8) 28.6 (63.0) 12

A1160-BF 305 (1000) 46.0 (18.0) 20.0 (7.9) 30.0 (11.8) 26.3 (58.0) 12

A1160-BVM 305 (1000) 53.0 (21.0) 20.0 (7.9) 30.0 (11.8) 39.0 (86.0) 12

AZ1160-BVM 305 (1000) 52.5 (21.0) 20.0 (7.8) 30.0 (11.8) 37.0 (82.0) 12

A1190-BVV 305 (1000) 46.0 (18.0) 20.0 (7.9) 30.0 (11.8) 28.6 (63.0) 12

A1190-BF 305 (1000) 46.0 (18.0) 20.0 (7.9) 30.0 (11.8) 26.3 (58.0) 12

A1190-BVM 305 (1000) 52.5 (21.0) 20.0 (7.9) 30.0 (11.8) 39.0 (86.0) 12

A11TS-BVV 305 (1000) 46.0 (18.0) 20.0 (7.9) 30.0 (11.8) 28.1 (62.0) 12

AZ11TS-BVV 305 (1000) 46.0 (18.0) 20.0 (7.9) 30.0 (11.8) 28.1 (62.0) 12

A11TS-BF 305 (1000) 46.0 (18.0) 20.0 (7.9) 30.0 (11.8) 28.1 (62.0) 12

A11TS-BVM 305 (1000) 52.5 (21.0) 20.0 (7.9) 30.0 (11.8) 36.7 (81.0) 12

AZ11TS-BVM 305 (1000) 52.5 (21.0) 20.0 (7.9) 30.0 (11.8) 37.0 (82.0) 12

A1177TS-BVV 305 (1000) 46.0 (18.0) 20.0 (7.9) 30.0 (11.8) 28.1 (62.0) 12

A1177TS-BF 305 (1000) 46.0 (18.0) 20.0 (7.9) 30.0 (11.8) 26.3 (58.0) 12

A1177TS-BVM 305 (1000) 53.0 (21.0) 20.0 (7.9) 30.0 (11.8) 36.7 (81.0) 12

A11QS-BVV 305 (1000) 50.0 (20.0) 20.0 (7.9) 30.0 (11.8) 29.0 (64.0) 12

AZ11QS-BVV 305 (1000) 50.0 (20.0) 20.0 (7.9) 30.0 (11.8) 29.0 (64.0) 12

A11QS-BF 305 (1000) 50.0 (20.0) 20.0 (7.9) 30.0 (11.8) 27.7 (61.0) 12

A11QS-BVR 305 (1000) 50.0 (20.0) 20.0 (7.9) 30.0 (11.8) 29.0 (64.0) 12

A11TS22-BVV 305 (1000) 52.5 (20.7) 20.0 (7.9) 30.0 (11.8) 27.7 (60.9) 12

A11TS22-BF 305 (1000) 52.5 (20.7) 20.0 (7.9) 30.0 (11.8) 27.7 (60.9) 12

A11TS22-BVM 305 (1000) 56.5 (22.2) 20.0 (7.9) 30.0 (11.8) 45.5 (100.1) 12

AZ11TS22-BVM 305 (1000) 56.5 (22.2) 20.0 (7.9) 30.0 (11.8) 45.5 (100.1) 12

Series 59A5967-BVV 305 (1000) 27.0 (11.0) 10.0 (3.9) 30.0 (11.8) 11.4 (25.0) 48

A5967-BF 305 (1000) 27.0 (11.0) 10.0 (3.9) 30.0 (11.8) 11.4 (25.0) 48

A5967-BVM 305 (1000) 34.0 (13.0) 12.5 (4.9) 30.0 (11.8) 15.4 (34.0) 27

A59TS-BVV 305 (1000) 27.0 (11.0) 10.0 (3.9) 30.0 (11.8) 11.4 (25.0) 48

A59TS-BVM 305 (1000) 34.0 (13.0) 12.5 (4.9) 30.0 (11.8) 15.4 (34.0) 27

A59QS-BVV 305 (1000)

A5995-HEC 305 (1000) 31.0 (12.0) 12.5 (4.9) 30.0 (11.8) 15.2 (6.9) 36

WIRE®

For information regarding specific cables, please visit www.pctinternational.com.© 2007-2011 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102

25www.pctinternational.com

CO R P O R AT E H E A D Q UA R T E R S2260 Westt Broadway RoadMesa, AZ 85202-1898USATel +1.480.813.0925Fax +1.480.545.1080 Customer ServiceToll Free +1.800.306.8948 or [email protected]

CANADAPCT Canada, Inc.a division of PCT International, Inc.41 Pullman Court, ScarboroughOntario M1X 1E4CANADATel +1.416.298.8551Fax [email protected]

CHINAPCT International (YANTAI)No. 1 Andrew AvenueMuping Economic Development ZoneYantai 264118CHINATel +86.535.471.0500Fax [email protected]

MEXICOPCT International, Inc.Calle de Futbol no. 149 Col. Country ClubMéxico DF 04220MEXICOTel +52.55.5689.6187Fax [email protected]

EUROPE/MIDDLE EAST/AFRICA/RUSSIA CISPCT EMEAFulya Mah. Mevlut Pehlivan Caddesi,Erdoganlar Is Merkezi 14/6 No: 9 34349 Mecidiyekoy, IstanbulTURKEYTel +90 212 217 62 66Fax +90 212 217 62 [email protected]

VIETNAMPCT Vietnam006 H1 Tower Hoang Dieu Street, District 4Ho Chi Minh City,VIETNAMTel +84.8.8255.984Fax [email protected]

PCT International, Inc. Subscriber Cable Division

For information regarding specific cables, please visit www.pctinternational.com.© 2007-2011 PCT International, Inc. | PCT.MOCSY7.CAT.200805e / 201102