DETTSON ALIZÉ INTERFACE (K03081) QUICK SETUP GUIDE 2016-10-07 X40237 rev. E Simple startup 1. Turn off the breaker of the outdoor unit and the furnace 2. Connect COND1 and COND2 on the interface board to N(1) and 2 at the outdoor unit (See complete manuel included with the unit) 3. Connect the interface board to the furnace: 1. Communicating thermostat: i. Connect the RJ-11 wire (A00443) between the interface and the furnace control board (See complete manuel included with the unit) 2. Legacy thermostat: i. Connect all the thermostat control wires to the interface card and the air handler control board ii. Make sure to connect the heat output W1 out and W2 out of the thermostat to the W1 and W2 inputs of the furnace –OR – W on W2 on a single stage thermostat iii. If the thermostat does not have a DH output, a jumper must be placed between R and DH on the interface board 4. Turn “ON” the breaker of the outdoor unit 5. Turn “ON” the breaker of the furnace Make sure the unit is working properly 1. The Green LED on the interface board should be blinking once every two seconds 2. The Orange LED on the interface board should be blinking once every two seconds 3. The communicating thermostat will display “Heat_Pump_Found” 4. Set the thermostat to “COOL” mode and adjust the set point to a lower value than the actual room temperature 5. The furnace and the outdoor unit should start within 5 minutes In this configuration, the interface board will gather information from both the outdoor unit and the furnace in order to adjust the fan speed to the capacity of the outdoor unit * Alizé 9/12 kBTU shown. See the Electrical Diagrams section of the Alizé manual for other models. INSTALLATION IN VARIOUS MODULATING FURNACES CHINOOK SUPREME Legacy wiring

Upload: buinhan

Post on 24-Jun-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

  • DETTSON ALIZ INTERFACE (K03081) QUICK SETUP GUIDE

    2016-10-07 X40237 rev. E

    Simple startup 1. Turn off the breaker of the outdoor unit and the furnace 2. Connect COND1 and COND2 on the interface board to N(1) and 2 at the outdoor unit (See complete manuel included with the unit) 3. Connect the interface board to the furnace:

    1. Communicating thermostat: i. Connect the RJ-11 wire (A00443) between the interface and the furnace control board (See complete manuel included with the unit)

    2. Legacy thermostat: i. Connect all the thermostat control wires to the interface card and the air

    handler control board ii. Make sure to connect the heat output W1 out and W2 out of the thermostat to the W1 and W2 inputs of the furnace OR W on W2 on a single stage thermostat

    iii. If the thermostat does not have a DH output, a jumper must be placed between R and DH on the interface board

    4. Turn ON the breaker of the outdoor unit 5. Turn ON the breaker of the furnace Make sure the unit is working properly 1. The Green LED on the interface board should be blinking once every two seconds 2. The Orange LED on the interface board should be blinking once every two seconds 3. The communicating thermostat will display Heat_Pump_Found 4. Set the thermostat to COOL mode and adjust the set point to a lower value than the

    actual room temperature 5. The furnace and the outdoor unit should start within 5 minutes

    In this configuration, the interface board will gather information from both the outdoor unit and the furnace in order to adjust the fan speed to the capacity of the outdoor unit

    * Aliz 9/12 kBTU shown. See the Electrical Diagrams section of the Aliz manual for other models.

    INSTALLATION IN VARIOUS MODULATING FURNACES CHINOOK SUPREME

    Legacy wiring

  • DETTSON ALIZ INTERFACE (K03081) QUICK SETUP GUIDE

    2016-10-07 X40237 rev. E

    Balance point adjustment Communicating thermostat: 1. On the thermostats Home Screen Display, touch the Menu key to display additional key choices 2. Touch and hold the Installer Config key for approximately 3 seconds to enter the Thermostat Configuration Menu 3. Touch and hold the Installer Config key for approximately 3 seconds to enter the Advanced Installer Configuration Menu 4. Using the up or down arrows, select THERMOSTAT 5. Touch the Installer Config key 6. Using the up or down arrows, select SETUP 7. Touch the Installer Config key 8. Using the up or down arrows, select BALANCE PT 9. Using the right or left arrows, set the desired balance point 10. Touch the Run Schedule key to return to the Home Screen

    Legacy wiring: 1. On the Interface Board, before powering the unit, set the balance point using the dipswitches #2, #3 and #4

    DIP2 DIP3 DIP4 Balance Point OFF OFF OFF -15C (5F) OFF OFF ON -13C OFF ON OFF -11C OFF ON ON -9C ON OFF OFF -7C ON OFF ON -5C ON ON OFF -3C ON ON ON HP heat only

    To run the outdoor unit in Air Conditioner mode (no heat), turn ON the dipswitch #1. ERV/HRV wiring The communicating thermostat (R02P029) is required

    1. Connect the ERV/HRV unit between the R and G terminals on the Interface Board 2. Connect the RJ-11 wire (A00443) between the interface and the furnace control board (See complete manuel included with the unit)

    3. Adjust the desired fan demand for ERV/HRV using the dipswitches #2, #3 and #4 DIP1 DIP2 DIP3 DIP4 Fan Demand

    - OFF OFF OFF 20% - OFF OFF ON 25% - OFF ON OFF 30% - OFF ON ON 35% - ON OFF OFF 40% - ON OFF ON 45% - ON ON OFF 50% - ON ON ON 55%

    DIP1 Mode OFF AC & HP ON AC Only

  • INTERFACE ALIZ DETTSON (K03081) GUIDE DINSTALLATION RAPIDE

    2016-10-07 X40237 rev. E

    Ajustement du point de basculement Thermostat communiquant: 1. Sur lcran daccueil du thermostat, appuyer sur Menu pour afficher les options additionnelles 2. Appuyer et maintenir la touche Installer Config environ 3 secondes pour afficher le menu de configuration du thermostat 3. Appuyer et maintenir la touche Installer Config environ 3 secondes pour afficher le menu de configuration installateur

    avanc 4. En utilisant les flches haut et bas, slectionner THERMOSTAT 5. Appuyer sur la touche Installer Config 6. En utilisant les flches haut et bas, slectionner SETUP 7. Appuyer sur la touche Installer Config 8. En utilisant les flches haut et bas, slectionner BALANCE PT 9. En utilisant les flches droite et gauche, ajuster le point de basculement la valeur dsire 10. Appuyer sur la touche Run Schedule pour revenir lcran daccueil

    Branchement legacy : 1. Sur la carte dinterface, avant dalimenter lunit, ajuster le point de basculement en utilisant les dipswitches #2, #3 et #4

    DIP2 DIP3 DIP4 Point de basculement OFF OFF OFF -15C (5F) OFF OFF ON -13C OFF ON OFF -11C OFF ON ON -9C ON OFF OFF -7C ON OFF ON -5C ON ON OFF -3C ON ON ON Chauffage thermopompe uniquement

    Pour mettre lunit extrieure en mode climatiseur seulement (pas de chauffage), mettre ON la dipswitch #1. Branchement ERV/HRV Le thermostat communiquant (R02P029) est requis

    1. Brancher lunit ERV/HRV entre les bornes R et G de la carte dinterface 2. Connecter le fil RJ-11 (A00443) entre linterface et la carte de contrle de la fournaise (Voir le manuel complet fourni avec lunit intrieure)

    3. Ajuster la demande de ventilation continue pour ERV/HRV en utilisant les dipswitches #2, #3 et #4 DIP1 DIP2 DIP3 DIP4 Demande de ventilation

    - OFF OFF OFF 20% - OFF OFF ON 25% - OFF ON OFF 30% - OFF ON ON 35% - ON OFF OFF 40% - ON OFF ON 45% - ON ON OFF 50% - ON ON ON 55%

    DIP1 Mode OFF Climatisation et chauffage ON Climatisation seulement

  • INTERFACE ALIZ DETTSON (K03081) GUIDE DINSTALLATION RAPIDE

    2016-10-07 X40237 rev. E

    Dmarrage simple 1. teindre le disjoncteur de lunit extrieure et de la fournaise 2. Connecter COND1 et COND2 de la carte dinterface N(1) et 2 de lunit extrieure (Voir le manuel complet fourni avec lunit) 3. Connecter la carte dinterface la fournaise:

    Thermostat communiquant: i. Connecter le fil RJ-11 (A00443) entre linterface et la carte de contrle de la fournaise (Voir le manuel complet fourni avec lunit)

    Thermostat legacy : i. Connecter tous les fils du thermostat la carte dinterface et la carte de

    contrle de lunit de ventilation ii. Sassurer de connecter les signaux en chauffage, sorties W1 et W2 connectes aux entres W1 and W2 de la fournaise OU W sur W2 pour un thermostat 1 stage iii. Si le thermostat ne comprend pas de sortie DH, un connecteur doit tre ajout entre les bornes R et DH sur la carte dinterface

    4. Mettre le disjonteur de lunit extrieure sur ON 5. Mettre le disjoncteur de la fournaise sur ON Sassurer que lunit fonctionne correctement 1. La LED verte de la carte dinterface doit clignoter toutes les deux secondes 2. La LED orange de la carte dinterface doit clignoter toutes les deux secondes 3. Le thermostat communicant doit afficher Heat_Pump_Found ( thermopompe

    dtecte ) 4. Rgler le thermostat en mode COOL (climatisation) et ajuster le point de consigne

    une valeur infrieure la temprature actuelle de la pice 5. La fournaise et lunit extrieure devraient dmarrer en moins de 5 minutes

    Dans cette configuration, la carte dinterface va rassembler en mme temps linformation sur lunit extrieure et sur la fournaise afin dajuster la vitesse du ventilateur la capacit de lunit extrieure

    * Aliz 9/12 kBTU montre. Voir la section Diagrammes lectrique du manuel de lAliz pour les autres modles.

    INSTALLATION DANS LES DIFFRENTS APPAREILS MODULANTS CHINOOK SUPREME

    Branchement legacy