79 lc lce 18€ limit control, manual reset, l4006e † pressure-temperature gage † 30 psi...
TRANSCRIPT
PB Heat, LLC Trade Price List (P-18) - Effective June 1, 2018 79
POWER BURNER
Series LC/LCE ™
• Large Commercial Boilers - Packaged, Assembled Block or Individual Sections
• Forced Draft Venting • Power Burners - Oil, Gas, Gas/Oil
• Steam or Hot Water Boilers • Optional Tankless Coils
Standard Equipment:• Cast Iron Sections - Factory Tested
• Wet Base Design, 50 PSI W.P. Sections
• Flex-Seal Gaskets
• High Temperature Rope Seal
• Insulated Enameled Steel Jacket
• Forced Draft Burner (WU, SU Models)
• Burner Mounting Plate w/Observation Port
• Cerafelt Base Liner and Target Wall
• Rear Observation Port
• Tankless Coil Cover Plates
• Front and Top Cleanout Plates
• Integral Cast Iron Flue Collector
• Rear Flue Outlet w/Locking Damper on LC
• Top Flue Outlet w/Locking Damper on LCE
• Steel Channel Rails (Field Assembled Boilers)
• Low Water Cut-Off (Packaged Boilers)
Water (LC-04 to LC-12):• Operating Limit Control, L4006A
• Limit Control, Manual Reset, L4006E
• Pressure-Temperature Gage
• 30 PSI Safety Relief Valve
Steam (LC-04 to LCE-24):• Operating Pressure Control, PA404A
• High Limit Pressure Control, Manual Reset, L4079B
• Steam Pressure Gage
• Gage Glass & Gage Cocks
• 15 PSI Safety Valve
SERIES LC/LCE™ BOILER RATINGS
Series LC/LCE™
BoilerModel
Oil Input1Gas
Input, MBH
GrossOutput,
MBH
Net Ratings4 Oil Gas
GPH MBHSteam,
sqftSteam3,
MBHWater2,
MBHCombustion
Efficiency5, %Thermal
Efficiency5, %Combustion
Efficiency5, %Thermal
Efficiency5, %
LC-04 4.75 665 686 547 1,708 410 476 83.7 82.2 81.2 79.8
LC-05R 5.60 784 808 649 2,029 487 564 83.7 82.8 81.2 80.3
LC-05 6.10 854 881 707 2,208 530 615 83.7 82.8 81.2 80.3
LC-06 7.50 1,050 1,077 868 2,713 651 755 83.7 83.1 81.1 80.6
LC-07 8.80 1,232 1,273 1,029 3,217 772 895 83.6 83.3 81.1 80.8
LC-08 10.20 1,428 1,469 1,189 3,717 892 1,034 83.6 83.5 81.1 81.0
LC-09 11.60 1,624 1,664 1,350 4,250 1,020 1,174 83.6 83.6 81.1 81.1
LC-10 12.80 1,792 1,860 1,511 4,804 1,153 1,314 83.6 83.7 81.1 81.2
LC-11 14.20 1,988 2,056 1,672 5,367 1,288 1,454 83.6 83.8 81.1 81.3
LC-12 15.60 2,184 2,252 1,832 5,917 1,420 1,593 83.6 83.9 81.1 81.4
LCE-13 17.00 2,380 2,464 1,966 6,358 1,526 N/A 83.5 82.2 81.0 79.8
LCE-14 18.40 2,576 2,657 2,125 6,875 1,650 N/A 83.5 82.5 81.0 80.0
LCE-15 19.80 2,772 2,850 2,284 7,388 1,773 N/A 83.5 82.6 81.0 80.2
LCE-16 21.00 2,940 3,043 2,444 7,908 1,898 N/A 83.5 82.8 81.0 80.3
LCE-17 22.50 3,150 3,236 2,603 8,421 2,021 N/A 83.5 82.9 81.0 80.4
LCE-18 24.00 3,360 3,429 2,763 8,938 2,145 N/A 83.5 83.1 81.0 80.6
LCE-19 25.00 3,500 3,622 2,922 9,454 2,269 N/A 83.5 83.2 81.0 80.7
LCE-20 26.50 3,710 3,815 3,082 9,971 2,393 N/A 83.5 83.3 81.0 80.8
LCE-21 28.00 3,920 4,027 3,256 10,533 2,528 N/A 83.6 83.3 81.1 80.8
LCE-22 29.50 4,130 4,239 3,430 11,096 2,663 N/A 83.6 83.4 81.1 80.9
LCE-23 31.00 4,340 4,451 3,604 11,658 2,798 N/A 83.7 83.5 81.2 81.0
LCE-24 32.50 4,550 4,663 3,777 12,217 2,932 N/A 83.7 83.5 81.2 81.0
BoilerH.P.
Approx.ShippingWeight
lbs
Less Burner
PackageAdder
TradePrice
16.3 2,104 $7,594 $4,046
19.4 2,483 $8,624 $4,249
21.1 2,483 $8,624 $4,249
25.9 2,862 $10,072 $4,652
30.7 3,241 $11,062 $4,854
35.5 3,620 $12,659 $5,162
40.3 3,999 $14,376 $5,360
45.1 4,378 $15,947 $5,566
50.0 4,757 $17,392 $5,868
54.7 5,136 $18,949 $6,071
58.7 5,515 $20,217 $6,271
63.5 5,894 $21,289 $6,474
68.2 6,273 $22,583 $6,652
73.0 6,652 $23,764 $6,880
77.7 7,031 $24,816 $7,080
82.5 7,410 $26,205 $7,281
87.3 7,789 $27,379 $7,482
92.1 8,168 $28,551 $7,807
97.3 8,547 $30,634 $7,968
102.5 8,926 $31,719 $8,173
107.7 9,305 $32,923 $8,372
112.8 9,684 $34,053 $8,580
1 Burner input based on No. 2 fuel oil with a heating value of 140,000 BTU per gallon.2 Net water ratings based on allowance of 1.15.3 Net steam ratings based on an allowance for LC-04 to LC-08=1.333, LC-09=1.323, LC-10=1.310, LC-11=1.298, LC-12=1.290, LCE-13 to LCE-24=1.288. 4 Consult factory before selecting a boiler for installation having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc.5 Combustion and thermal efficiency determined in accordance with BTS 2000 Testing Standard.
Visit www.PeerlessBoilers.com for Additional LC/LCE™ Product Specifications, Warranty and Extended Warranty Information See pages 103-104 for Notes; pages 109-112 for Optional Controls and Components and
page 112 for Tankless Water Heater Ratings.
80 PB Heat, LLC Trade Price List (P-18) - Effective June 1, 2018
Series LC/LCE ™
Ordering Information:Example:
O – LC/LCE – 06 – WU –STD – 30PSI
Sects. STD, FMSeries 15 PSI Steam (STD)
30 PSI Water (STD)Blank = No Burner 50 PSI O = Oil 80 PSI G = Gas WATER STEAMGO = Gas/Oil W S = Less Burner (KD)
WU SU = w/ Burners & Contr. (KD)WUP SUP = Pkg. w/Burn. &
ControlsWP SP = Pkg. Less Burner
OPTIONAL EQUIPMENT TRADE PRICESAdd to Trade Price
Description Trade Price
80 PSI Working Pressure Sections (water only)*50 PSI Relief Valve (in lieu of standard)
$87 Per SectionNo Charge
Factory Assembled Sections $168 Per Section
1-1/2″ Inspection Tappings(Two per section / RH side)
w/brass plugw/nipple & cap
$113 Per Section$134 Per Section
Mounting of Optional Controls on Packaged Boilers $132 Per Control
Factory Fire Test of Packaged Boilers (Nat. Gas or #2 Oil)Functional w/o Combustion ReportComprehensive w/Combustion Report
$499$993
Barometric Draft Dampers Code No.
LC-04 thru LC-05 9″ 50255LC-06 thru LC-08 10″ 90391LC-09 thru LC-12 12″ 90394LCE-13 thru LCE-1714″ 91198LCE-18 thru LCE-2416″ 90396Thermal Switch for Draft Damper 50702
$219$282$351$501$614$176
*30 PSI relief valve furnished unless otherwise specified on order
DOMESTIC WATER COILSCode No. Capacity, gal/min.
200 Boiler Water❖PressureDrop-PSI
Inlet/OutletTapping
ShippingWeight Lbs.
TradePrice
90534 X-1020 3 3 3/4" 25 $294
90537 X-1021 6 5 3/4" 33 $631
90539 X-1022 6.5 12 3/4" 33 $921
❖Intermittent draw 100°F average rise
PB Heat, LLC Trade Price List (P-18) - Effective June 1, 2018 91
CRATE DIMENSIONSBoilerModel Length Width Height
LC-04LC-05RLC-05
78″83″83″
58″58″58″
75″75″75″
LC-06LC-07LC-08
88″93″102″
58″58″58″
75″75″75″
LC-09LC-10LC-11
107″112″117″
58″58″58″
75″75″75″
LC-12LCE-13LCE-14
122″127″132″
58″58″58″
75″75″75″
LCE-15LCE-16LCE-17
137″142″151″
58″58″58″
75″75″75″
LCE-18LCE-19LCE-20
156″161″166″
58″58″58″
75″75″75″
LCE-21LCE-22LCE-23LCE-24
171″171″182″187″
58″58″58″58″
75″75″75″75″
Series LC/LCE ™
Visit www.PeerlessBoilers.com for Additional LC/LCE™
Product Specifications, Warranty and ExtendedWarranty Information See pages 103-104 for Notes; pages 109-112 for Optional Controls and
Components and page 112 for Tankless Water Heater Ratings.