8-13 mckenzie arena tech pack · house sound jbl bi-amped with crown amplifiers. positions:...
TRANSCRIPT
UTC McKenzie Arena Technical Pack
This publication contains the technical information needed by promoters and lessees for McKenzie Arena events
Last Updated 5/1/2019
Mailing Address Shipping Address
University of Tennessee at Chattanooga University of Tennessee at Chattanooga McKenzie Arena McKenzie Arena Dept. 3403 720 E. Fourth Street615 McCallie Avenue Chattanooga, TN 37403Chattanooga, TN 37403
Phone Numbers
Administrative Offices 423.425.4706
Box Office Business Phone 423.425.4780
Ticket Sales Phone 423.266.6627
Contacts
Obie Webster Executive Director of Entertainment & Sports Venues 423.425.4721
Kyle Askew Technical Director 423.425.4746 [email protected]
Arland Jenkins Operations Coordinator 423.425.4648
Sandra Farris Event Coordinator/Accounting 423.425.4030
Box Office Supervisor 423.425.5873
Arena Information
Reserved Seating Capacity
IN THE ROUND END STAGE SIDE STAGE
11,557 9,107 7,463
(Final figures vary based on stage size and placement)
Floor Dimensions
Full floor: 181’9” by 151’6” with all bleacher seating fully closed. Oval (basketball) configuration: 110’9” by 86’ with all bleachers fully extended.
House Lights
LED Lighting. Master blackout only – no dimmers. Controls located back stage left. Total blackout prevented by exit, aisle, and emergency lights. Follow spots: Six xenon Super Trouper 1.6 kW (100’ max/50’min throw) with 10 platform locations.
House Sound
JBL bi-amped with Crown amplifiers. Positions: permanent. Sound level restrictions: 96 db average/110 db peak. House intercom: 3 pin and 4 pin dry lines in 11 locations.
Stage
Sico Roll N’ Set mobile performance stage, skirt drapery available Maximum size: 64’ by 48’ in 8’ by 8’ sections. Stage height: adjustable to 4’, 5’ Seven 4’x8’x16” parallels and risers are available. Barricade length: 80’ – 4’x4’ 2 stair units available with handrails. 8’ fire aisles must be maintained on both sides of stage. Equipment case storage is backstage. House crew sets up stage, barricade and mixer platforms.
Pyrotechnics/Safety
Advance notification and licenses required. Pyrotechnic restrictions apply. Fire Marshall/UTC Safety Department representatives will inspect and attend all shows. 8’ fire aisles must be maintained on both sides of stage. Equipment case storage is backstage. Please call Arena Event Coordinator in advance to arrange necessary licenses.
Rigging
Ceiling over center floor: open steel truss. I-beam distance: 29’ apart. Floor to low steel height: 77’6” Low steel to ceiling distance: 20’9” Scoreboard is roughly 27' long x 15' wide. 54' to the bottom of it at high trim. (4) sound clusters around the scoreboard
Electrical
Source 1: 600 amps/leg, 3 phase, 208 volt (show power) Source 2: 600 amps/leg, 3 phase, 208 volt (show power) Source 3: 200 amps/leg, 3 phase, 208 volt (show power) Source 4: 100 amps/leg, 3 phase, 208 volt (show power) Source 5: 200 amps/leg, 3 phase, 208 volt (normally TV hookup) Located by ramp door.
Special Equipment
One 5000 pound capacity propane forklift, 15’ extended mast height, 4’ fork length. Additional fuelstored in building.
Welding machine. Six xenon Super trouper follow spots (100’ max/50’min throw) with 10 platform locations.
Dressing/Hospitality/Production Rooms
Dressing Room 1: First Floor backstage, common showers. Dressing Rooms 2 – 5: Second Floor backstage, individual shower in each. Production Offices: First Floor backstage, two available. Press and Hospitality Rooms available. Communications: one phone line per room (local calls only provided, long-distance on credit card),
University’s open wireless internet available in all rooms (password required), EPB internet alsoavailable in larger production office.
Novelties/Catering
House does not sell. 80/20 merchandising split. If needed: CAM Merchandising, Ronnie Dodd. 423.877.0399 (voice & fax) or 800.600.2481 (pager). Catering provided by Aramark. Campus contact phone: 423.425.4200.
Box Office/Ticketing
On-site computerized ticketing system with internet sales. Visa/Mastercard/American Express and Discover are accepted. Regular Box Office Hours: Mon-Fri, 10am to 5pm and during all events. Saturday hours can be
arranged for pre-event sales.
Parking/Loading
Load-in Ramp: located on southeast side of building from Mabel Street. Entrance: 13’10” H by 12’4” W. Building will accommodate a 13’6” truck inside. Truck parking available in designated University lots (usually lot 34). Trucks cannot park on city streets.
Staffing
Production Staffing: promoter/lessee preference. Two local contacts are:
Crew One. Contact 615.242.4433
IATSE Local 140. Contact Bob Hasselle 423.933.4658
Event Staffing – Employed by UTC Arena
Medical – 2 Ushers – TBDSecurity – TBD Ticket takers – TBD Box Office – TBD Event Coordinator – 1
Staffing levels are determined by size of anticipated crowd, type of event and artist rider requirements.
Cto D
BtoC
Ato B
A to A
Vl (")
�,,, \ :·
\
i \
;,-___ "-._'\_/_/_� __ i_1
_TR_u_s_s_!._·o_" __ ::_-_-_\-_;.;...,;:, _,'_,_"-...;.,,_ .. _/ _
27'J. __ \ ____ \\ ____ i __ ;_-_�_:_-_- _-_-_-_._-_, _ ___.;. __ ,_;,,_! ____ _ l - TRUSS ! "C" I : ! I
2/'s" f / TRussl..... U �j \ C
;v,.., I i-0<
II \
� S'S" 1;� TRUSS "A" �-----,
1,
•
I I ,
--,;-;;-, •
l ,30'0"
TRUSS 1"A" I L_[)j � �� \ i I 1 ! i
)9
�\,
---:-\ ---:-\
\
_T_R_us_s _\"B_" __
1
__ ...;..
1__,
1_--_; -_-_-_-...;.; __ _;___
1TYP. i:,1 .. • t
I. , • :SJ', • • <lo,·' TRUSS "C" . ! ;\,' I .! TRUSS ,"D"
______________ ..,;.... __________ 'c:1 /' Ii .·· '-
// � / \ ' ·. /
(") :r )> ���c 0 .... on " ?- ?o� ,,, l"'IZ z )> z ,..,1/1 1/1 ,.., ,..,
:::0 0
�o :::0 ..,, �al -0 z -i � -i "'O 0 r�
� ('):i:0 :::0 Cl
I / • --- ___ :_'-,I .-i\
Floor to Truss Height = 77'6"
THE C
ON
CEPTS EXPR
ESSED AN
D D
ETAILS SHO
WN
ON
THIS D
RAW
ING
ARE C
ON
FIDEN
TIAL AND
PRO
PRIETAR
Y. DO
NO
T REPR
OD
UC
E BYAN
Y MEAN
S WITH
OU
T THE EXPR
ESS WR
ITTEN C
ON
SENT O
FD
AKTRO
NIC
S, INC
. OR
ITS WH
OLLY O
WN
ED SU
BSIDIAR
IES.C
OPYR
IGH
T 2018 DAKTR
ON
ICS, IN
C. (U
SA)
THIR
D AN
GLE PR
OJEC
TION
BH
27'-5.3"22'-2.1"
11'-9.3"
14'-10.7"
8'-7.8"
11'-0"
LED VID
EO D
ISPLAYLED
VIDEO
DISPLAY
REV
TITLE:
PROJECT:
INC
HES [M
ILLIMETER
S]
DESIGN:
SCALE:
DIM UNITS:
DATE:SHEET
DO
NO
T SCALE D
RAW
ING
FUNC - TYPE - SIZEDRAW
N:-
JOB NO
.-
UN
IVERSITY O
F TENN
ESSEE / CH
ATTANO
OG
A, TN4 SID
ED C
ENTER
HU
NG
DISPLAY
BWEN
DLI
15 FEB 18
P7000P
08B
1=50
3850612 A
P.L. #334209
CEN
TERS
-LINES O
F LEDS AR
E ON
6 mm
672 CO
LUM
NS O
F RESO
LUTIO
N W
IDE
-384 LINES O
F RESO
LUTIO
N H
IGH
xEN
D LED
VIDEO
DISPLAY: (D
VN-903-6M
N) @
2
-ACTIVE: 8'-3" H
IGH
x 14'-6" WID
E
FOR
CO
NSTR
UC
TION
PUR
POSES
APPRO
VED SH
OP D
RAW
ING
S SHO
ULD
BE USED
TO D
ETAILED D
ESIGN
CO
NSID
ERATIO
NS/O
NLY
-DIM
ENSIO
NS AR
E SUBJEC
T TO C
HAN
GE D
UE
-DISPLAY FIN
ISH TO
BE SPECIFIED
-ALL ALUM
INU
M C
ON
STRU
CTIO
N-SIN
GLE FAC
EG
ENER
AL DISPLAY:
WR
ITTEN C
ON
SENT O
F DAKTR
ON
ICS, IN
C.
BY ANY M
EANS W
ITHO
UT TH
E EXPRESSED
FRO
M AR
TWO
RK SH
OW
N. D
O N
OT R
EPRO
DU
CE
FINAL D
ESIGN
AND
APPEARAN
CE M
AY DIFFER
NATU
RE. C
ON
FIDEN
TIAL AND
PRO
PRIETAR
Y.EXPR
ESSION
S SHO
WN
ARE C
ON
CEPTU
AL INAD
CO
PY APPRO
VAL. THE D
ETAILS AND
DO
NO
T USE FO
R D
ESIGN
/ENG
INEER
ING
OR
POW
ER R
EQU
IREM
ENTS AR
E VALID FO
R60 D
AYS FRO
M TH
E DW
G/R
EV. DATE.
-SIDE LED
VIDEO
DISPLAY: (D
VN-6M
N) @
2ESTIM
ATED PO
WER
DEM
AND
:41,300 W
ATTS
CEN
TERS
-LINES O
F LEDS AR
E ON
6 mm
1008 CO
LUM
NS O
F RESO
LUTIO
N W
IDE
-528 LINES O
F RESO
LUTIO
N H
IGH
xSID
E LED VID
EO D
ISPLAY: (DVN
-903-6MN
) @2
- ACTIVE: 11'-5" H
IGH
x 21'-10" WID
E
-END
LED VID
EO D
ISPLAY: (DVN
-6MN
) @2
20,100 WATTS
-DISPLAY TO
TAL:61,400 W
ATTS
*EXCLU
DIN
G C
HAN
NEL LETTER
S/LOG
O
-CO
LOR
S TO BE SPEC
IFIED
-CH
ANN
EL LETTERS AR
E 18" HIG
H, ILLU
MM
INATED
IDEN
TIFICATIO
N D
ISPLAY:
-CH
ANN
EL "C" LO
GO
S ARE 24" H
IGH
, ILLUM
MIN
ATED
TOP VIEW
NO
T TO SC
ALE
-LOG
O IS 90" H
IGH
UN
DER
BELLY DISPLAY:
-DISPLAY FAC
E PRIN
TED M
ESH M
ATERIAL
UN
DER
BELLY DISPLAY
NO
T TO SC
ALE
SIDE VIEW
END
VIEW