1. AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PERCODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXX ASAPPROPRIATE FOR INSTALLATION.
WIRE ROUTED THROUGH FLOOR IN THIS AREA.
NOTES:
3
WIRES ROUTED UNDER FLOOR.
SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
12D
2.
265
2651B1
CODES/STANDARDS USA1B1
CODES/STANDARDS-CSA/CMVSS
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
4
ELECTRICAL SYSTEM 30 AMP
3
401 INVERTER-DC/AC, 1000 WATT
4
401
INVERTERDETAIL CF 3
110V CONNECTIONSDETAIL AA
(BLU)1600 LOOPTHRU GALLEY GFI RCPTHRU GALLEY RCP-B(BLU THROW IN WIRE #2)1500 DROPTHRU RCP-B GALLEYDETAIL CA(BRN-2,YEL,BLK)1200 DROPTO SLIDEOUT CONNECTORSDETAIL DA
401
(UNDER REFRIG)
FROMINVERTER
OUTPUT
(BRN)FROM RCP-BDETAIL BC
FROMINVERTERINPUT
THROW INWIRE #5
5
(BRN-2)TO RCP-B BATHDETAIL BB
401
5
DETAIL AA
(UNDER REFRIG)
WHITE TOAUTO LOADSHED MODULE
WITHOUT INVERTER THROW IN #2 (BRN-2) CONNECTS TO(BRN) FROM LOAD CENTER.
5
RCP-2 (BLU)EXT COMPT
4
4
AB
VIEW AB
TOGENERATOR
MAIN TOLOAD CENTER
POWERCORD
ATS3
WHITE TO WATER HEATER
(RED)4200 DROPTO RCP-B BATH OVHD(BLU)3800 DROPTO VANITY RCP(BRN-2)9000 LOOPTHRU RCP-2 HALLWAYTHRU RCP-2 MAIN TVTHRU RCP-B UNDER LAV CABINETTO GALLEY SLIDEOUTCONNECTORS
PANEL-RECEPTACLE151376-01-CHTSCREWG39-08-12U (4)
THROW IN WIRE #2(BLU)TO RCP-B GALLEYDETAIL CA
CLAMP10497-03-000
CLAMP10497-10-000
3
UNSPECIFIED TOLERANCES: MATERIAL:
C
D
1
TWO-PLACE (X.XX)
DSNR:
DESCRIPTION:
8
2
B
ALL DIMENSIONS ARE IN MILLIMETERSDFTR:
6
A
6
FIRST USED:
A
REV
WHOLE DIM (X)
D
REF:
8
ITEM/PART NO:
4
WEIGHT: (LBS)
SHEET:
7
B
2
4
REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES
ANGLE
5
5
13
COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC.
ONE-PLACE (X.X)
C
7
WIRING INSTL-BODY,110V
1 OF 6 000161553 / 32836001000
3
1.5
0.50
1
19 F27N
COVER-INVERTER000034393 / 317773-01-CHTSCREWG11-08-12U (6)
12D
ALL WEATHER UPGRADE PACKAGE078
ATS
TOGENERATOR
POWERCORD
MAIN TOLOAD CENTER
CLAMP10497-03-000
078VIEW AB
3
3
CLAMP10497-10-000
GROMMET-RUBBER-2 OD023942-01-000
GROMMET-RUBBER-2 OD023942-01-000
25-Jun-2019
AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PERCODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXX ASAPPROPRIATE FOR INSTALLATION.
1.
2
SPACER-RECP133713-04-CHTSCREWG11-08-20U (4)
NOTES:
4 WIRE ROUTED IN SIDEWALL
WIRE ROUTES THRU FLOOR IN THIS AREA.
265
2651B1
1B1
CODES/STANDARDS-CSA/CMVSS
CODES/STANDARDS USA
3
DETAIL BA
WIRE PART OF WIRE ASM-CHASSIS.
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
110V CONNECTIONDETAIL BA
CONNECTOR-WIRE,NM144283-02-000 (2)SCREWG39-06-24U (4)
FROM110V CONNECTION
UNDER BED(BRN)
DETAIL BE
CLAMP10495-01-000 (4)SCREWG67-10-12U (4)
TO RCP-DINETTE
4
2
RCP-2 (BLU)BATH VANITY
RCP-2 (DET BD)MAIN TV
RCP-B (DET BB)UNDER LAV CABT
5
TO GALLEY SLIDEOUT CONNECTORDETAIL DA
DETAIL BB
TO RCP-BBATH OVHD
RCP-B(UNDER LAV CABT)
(BRN-2)FROM RCP-
MAIN TV
RCP-B (RED)BATH OVHD
4
RCP-B (DET CB)BATH OVHD
SP-04 RCP-2 (BRN-2)LEFT,REAR
110V CONNECTIONDETAIL BE
FROM LOAD CENTER
RCP-B(UNDER BED)
(BRN)
DETAIL BC
TO INVERTER INPUT
FROM INVERTER
RCP-2(MAIN TV)(BRN-2)
DETAIL BD
TO RCP-BUNDER LAV CABINETDETAIL BB
TO 110V CONNECTORUNDER BEDDETAIL BE
DETAIL BE
TO RCP-BUNDER BED
TO DINETTECONNECTOR
DETAIL BA
CLAMP10495-01-000 (2)SCREWG67-10-12U (2)
3
THROW IN WIRE #1
THROW IN WIRE #6
THROW IN WIRE #1
3
5 SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.
MODULE-AUTOLOAD SHED
RCP-2 (BRN)DINETTE
RCP-BATHVANITY
FROM RCP-B(GALLEY)
RCP-2(HALLWAY)
(BLU)
DETAIL BG
RCP-2 (DET BG)HALLWAY
3
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,110V
000161553 / 32836001000 2 OF 6
LOAD CENTER/ATS ASM000163995 / 328991-01-000
RCP-B (GRN)BATH OVHD
ALL WEATHER UPGRADE PACKAGE078
078
RCP-B (DET BC)BED
ELECTRICAL SYSTEM 30 AMP12D
RCP-1 (YEL)CONVERTER078
25-Jun-2019
5
CODES/STANDARDS USA
WIRES ROUTED IN ROOF.
CODES/STANDARDS-CSA/CMVSS
1B1
2653
1B1
265
WIRES ROUTE THRU FLOOR IN THIS AREA.
4
RCP-2 (BRN-2)SDWL,RH,FRONT
AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PERCODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXX ASAPPROPRIATE FOR INSTALLATION.
NOTES:
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
SP-04
2
WIRES ROUTED IN SIDEWALL.
1.
4
DETAIL CD
TO FRONT RCPSFROM LOAD CENTER
DETAIL CC
RCP-BBATH OVHD
(RED)
DETAIL CB
RCP-BBATH OVHD(BRN-2)
FROM RCP-B BATHDETAIL BB
TO FRONT RCPS
DETAIL CA
RCP-BUNDER GALLEY CABT.
(BLU)FROM RCP-
EXTERIOR
TO GALLEYSLIDEOUT CONNECTIONSDETAIL DA
RCP-2 (BLU)GALLEY FRT SP-04 4
4
5
5
RCP-2EXT TV(BRN-2)
FROM GALLEYSLIDEOUT CONNECTORS
DETAIL DATO RCP-ENT CTR
6RCP-2 (DET CD)EXT ENT CTR TV
RCP-2 (DET CD)BDRM TV
RCP-B (DET CA)GALLEY
RCP-1 (BLK)MICROWAVE
RCP-3 (YEL-2)REFRIGERATOR
4
3
110V CONNECTIONSTO SLIDEROOMDETAIL DA
6
SEE LOAD CENTER/ATS ASM FOR ADDITIONALINFORMATION.
4
4
THROW IN WIRE #2
4
THROW IN WIRE #6
FROM GFIRCP GALLEY
TO RCP-HALLWAY
THROW IN WIRE #2
4
2
CLAMP10497-10-000
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,110V
000161553 / 32836001000 3 OF 6
RCP-B (BRN-2)RH FRONT
RCP-2 (BRN-2)TV OVHD
THROW IN #7
RECEPTACLE ASM-GFI,US-15A000120175 / 322736-01-XXXRECEPTACLE ASM-GFI,CAN-15A000120176 / 322737-01-XXX(BLU)(GALLEY)
1B1
265
CLAMP10495-01-000SCREWG67-10-12U
110V CONNECTORS(REF)
SWITCH-TRANSFER,INVERTER, 15 AMP000033766 / 318693-01-000SCREWG67-10-12U (2)
INVERTER-1000W, NO TRANSFER000033749 / 318692-01-000SCREWG39-10-16U (4)
3
CONNECT INVERTER INPUT TO BRN WIRE.CONNECT INVERTER OUTPUT TO BRN-2 WIRE.
DETAIL CF
DETAIL CE
RCP-2ENT CTR(BRN-2)
FROMRCP-EXT TV TO RCP-BDRM TV
RCP-2 (DET CE)ENT CTR
25-Jun-2019
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
CODES/STANDARDS-CSA/CMVSS
2651B1
265
CODES/STANDARDS USA1B1
NOTES:
WIRE ROUTED IN SIDEWALL.1
CONNECTOR-PLASTIC008356-01-000 (2)
FROM LOAD CENTER
DETAIL DA
FROM RCP-MAIN TV
LOCATED UNDERTHE GALLEY CABT
SLIDEOUT WIRE #3(BRN-2)
TO RCP-2 GALLEY
CLAMP10495-04-000SCREWG67-10-12U
CONNECTOR-WIRE,NM CLEAR144283-02-000 (3)
LOCATED INGALLEY CABT CLAMP
10495-01-000 (14)SCREWG67-10-12U (14)
BOX-4X48289-01-000COVER-4X48294-01-000WIRE ASM-GROUND133678-01-000SCREW-GROUND103291-01-000WIRE NUT8313-01-000 (3)SCREWG11-08-12U (2)
CLAMP10495-04-000SCREWG67-10-12U
SLIDEOUT WIRE #1(BLU)
TO REFRIGERATOR
SLIDEOUT WIRE #2(YEL)
FROM RCP-B GALLEY
TO RCP-2 BDRM TV
TO MICROWAVEFROM AUTO LOAD SHED
BRACKET-110V CONNECTOR155223-06-CHT (2)SCREWG39-10-12U (6)
SLIDEOUT WIRE #4(BLK)
BOX-4X48289-01-000COVER-4X48294-01-000WIRE ASM-GROUND133678-01-000SCREW-GROUND103291-01-000WIRE NUT8313-01-000 (3)SCREWG11-08-12U (2)
CONNECTOR-PLASTIC008356-02-000 (2)
1
1
1
1
THROW IN WIRE #2
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,110V
000161553 / 32836001000 4 OF 625-Jun-2019
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
NOTES:
20
NOTES:
14-2
3
SEE MANUFACTURER'S DIAGRAM.
110V CONNECTION(UNDER BED)
12-2
2654
2
12-2
ENTERTAINMENT CENTR/EXT W/CD/TV
1B1 CODES/STANDARDS USA
1
1D3
RCP-SIDEWALL(DINETTE)
PRIMARY
RCP-BDRMLEFT,REAR
15
SECONDARY
W/OUT INVERTER THROW IN WIRE #5 (BRN-2)CONNECTS TO (BRN) WIRE.
110V CONNECTION(UNDER GALLEY
CABT)
2651B1
5
10-2
NEUTRAL
ALL OUTLETS DOWN STREAM AND INCLUDINGTHIS OUTLET ARE GROUND FAULT INTERRUPTPROTECTED.
20
CONTROL CENTER
EMSRELAY
WATERHEATER
CODES/STANDARDS-CSA/CMVSS
5
LINE
30
CHASSISGROUND
WIRE IN SIDEWALL.
110V CONNECTION(SLIDEROOM UNDER
GALLEY CABT)
12-2
15
ROOFAIR
CONDITIONER
8 GRN
110V CONNECTION(UNDER DINETTE)
WIRE IN ROOF.
6
NEUTRAL
RCP-MICROWAVE
15
NEUTRAL
WIRE ROUTED UNDER FLOOR.
14-2
RCP-REFRIGERATOR
SLIDEOUT WIRE #2
WHT
SLIDEOUT WIRE #4
RCP-BLANKUNDER BED
THROW IN WIRE #1
FLEX CORD
SLIDEOUT WIRE IS PART OF WIREASM-CHASSIS
4
3
4
4
4
POWERCORD
10-2
RCP-BLANK,BATH
RCP-GFIGALLEY
RCP-EXTERIOR
110V CONNECTION(GALLEY ISLAND)
RCP-GALLEY
GENERATOR
1
4 RCP-BLANK(UNDER GALLEYISLAND)
RCP-OVHD A/V
CABT
4
3
SLIDEOUT WIRE #1
INVERTERTRANSFER
SWITCH
110V CONNECTION(RT COMPT)
110V CONNECTION(RT COMPT)
401RCP-
HALLWAY
RCP-SAT PREP
THROW IN WIRE #5
6
6
RCP-BBATH
2
RCP-BBATH OVHD
RCP-SDWL,RH,FRONT
AUTOMATICTRANSFER
SWITCH
10-2
110V CONNECTION(UNDER GALLEY
ISLAND)
110V CONNECTION(UNDER GALLEY
ISLAND)
2
110V CONNECTION(IN GALLEY
CABINET)
THROW IN WIRE #2
RCP-MAIN TV
110V CONNECTION(GALLEY ISLAND)
110V CONNECTION(GALLEY CABT)
RCP-EXTENT CTR
RCP-TV OVHD
RCP-BATHVANITY
1D3
SLIDEOUT WIRE #3
THROW IN WIRE #6
2
2
2
2
2
4
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,110V
000161553 / 32836001000 5 OF 6
RCP-BRH FRONT
RCP-BDRM TV
THROW IN #71D3
25-Jun-2019
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
14-2
110V CONNECTION(UNDER BED)
265
1B1 CODES/STANDARDS USA
RCP-SIDEWALL(DINETTE)
PRIMARY
RCP-BDRMLEFT,REAR
SECONDARY
W/OUT INVERTER THROW IN WIRE #5 (BRN-2)CONNECTS TO (BRN) WIRE.
110V CONNECTION(UNDER GALLEY
CABT)
2651B1
NEUTRALEMSRELAY
WATERHEATER
CODES/STANDARDS-CSA/CMVSS
5
LINE
12-2
110V CONNECTION(UNDER DINETTE)
6
NEUTRAL
RCP-MICROWAVE
NEUTRAL
14-2
WHT
SLIDEOUT WIRE #4
RCP-BLANKUNDER BED
THROW IN WIRE #1
FLEX CORD
SLIDEOUT WIRE IS PART OF WIREASM-CHASSIS
4
4
4
RCP-GFIGALLEY
RCP-EXTERIOR
RCP-GALLEY
1
4
RCP-BLANK(UNDER GALLEYISLAND)
RCP-OVHD A/V
CABT
4
3
SLIDEOUT WIRE #1
INVERTERTRANSFER
SWITCH
110V CONNECTION(RT COMPT)
110V CONNECTION(RT COMPT)
401
RCP-HALLWAY
RCP-SAT PREP
THROW IN WIRE #5
6
6
RCP-BBATH
2
RCP-BBATH OVHD
RCP-SDWL,RH,FRONT
110V CONNECTION(UNDER GALLEY
ISLAND)
110V CONNECTION(UNDER GALLEY
ISLAND)
2
110V CONNECTION(IN GALLEY
CABINET)
THROW IN WIRE #2
RCP-MAIN TV
110V CONNECTION(GALLEY ISLAND)
110V CONNECTION(GALLEY CABT)
RCP-EXTENT CTR
RCP-TV OVHD
RCP-BATHVANITY
1D3
THROW IN WIRE #6
2
2
4
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,110V
000161553 / 32836001000 6 OF 6
RCP-BRH FRONT
RCP-BDRM TV
THROW IN #7
WHT
3
WIRE SUPPLIEDWITH GENERATOR
YEL 2
WHT
BLK
WHT
BLK
BLK
BLK/YEL
RED
RED
WHT
3
8 GRN
6-3
FRONTROOF AIR
CONDITIONER
NOTES:
N
3
GROUND
5ALL WEATHER UPGRADE PACKAGE
12-2
REARROOFAIR
CONDITIONER
12-2
RECP-BLANK,BATHWALL-1
50
8 GRN
14-2
WIRE IS PART OF WIRE ASM-CHASSIS.
4
LOAD CENTER
RCP-BLANK,BATHWALL 3
12-2
12-2
L1
2020
R2
AUTOMATICTRANSFER
SWITCH
R1
15
WIRE IN ROOF.
14-2
2
8 GRN
078
POWERCORD
RCP-REFRIGERATOR
GENERATOR
15
WIRE IN SIDEWALL.
12-2
50 2015
12-2
CHASSISGROUND
EMS
12-2
RCP-CONVERTER
GROUND
ALL OUTLETS DOWN STREAM AND INCLUDING THISOUTLET ARE GROUND FAULT INTERRUPT PROTECTED.
WATER HEATER(LOCATEDBENEATH
GALLEY CABT)
15
SEE MANUFACTURER'S DIAGRAM FOR ADDITIONAL INFORMATION.
1
6-3
14-2
14-2
L2
8 GA
15
SLIDEOUT WIRE #3
2
078
RCP-EXTENT CTR
25-Jun-2019