8 7 6 5 4 3 1 2copyright 2016 winnebago industries, inc. one-place (x.x) c 7 wiring instl-body,12v 1...

6
VIEW AA 1. 265 AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATE FOR INSTALLATION. CODES/STANDARDS USA CODES/STANDARDS-CSA/CMVSS 1B1 1B1 NOTES: 265 SWITCH DETAIL DJ PLATE-WALL 149557-03-CHT SCREW G39-08-12U (2) PORT-SOLAR,SINGLE 191558-01-000 SCREW G39-10-12U (4) PANEL-SERVICE 000017108 / 313328-01-CHT SCREW G39-08-12U (4) WIRE ASM-TANK, MAIN HOLDING 151317-04-000 WIRE ASM- HEATER,TANKS 191919-01-000 WIRE ASM-TANK, AUX HOLDING 151316-04-000 AA 3 GROMMET 114208-06-000 PSSLED-2 DRAINAGE SYSTEM/HEAT-PREWIRE 23R DRAINAGE SYSTEM-HEATED 23T SPLICE YELLOW TO RED AND WHITE TO BLACK. 2 23T 2 23R GROMMET 023942-01-000 3 WIRE PASSES THROUGH FLOOR IN THIS AREA. 3 HARNESS- SLIDEOUT MOTOR 191660-01-000 HARNESS- SLIDEOUT MOTOR 191660-01-000 3 UNSPECIFIED TOLERANCES: MATERIAL: C D 1 TWO-PLACE (X.XX) DSNR: DESCRIPTION: 8 2 B ALL DIMENSIONS ARE IN MILLIMETERS DFTR: 6 A 6 FIRST USED: A REV WHOLE DIM (X) D REF: 8 ITEM/PART NO: 4 WEIGHT: (LBS) SHEET: 7 B 2 4 REFER TO ES0018 FOR FASTENER TIGHTENING GUIDELINES ANGLE 5 5 1 3 COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC. ONE-PLACE (X.X) C 7 WIRING INSTL-BODY,12V 1 OF 6 000120921 / 32287801000 3 1.5 0.50 1 X-X FOR ELECTRICAL CALLOUTS SEE DWG NO. 121339-01-000 FOR ELECTRICAL TORQUE SPECIFICATIONS SEE DWG NO. 128783-01-000 18 423A VIEW AB AB JACKS-STABILIZING, ELECTRIC 64A PANEL-SWITCH 000028367 / 316237-01-CHT SWITCH-ROCKER 108357-06-000 (2) ACTUATOR 108356-01-CHT (2) LABEL-STABILIZER 000007799 / 310651-01-CHT 138 INSIDE WALL OF COMPARTMENT SCREW G39-08-12U (2) 4 WITH LAMP TO BE MOUNTED ON UNDERSIDE OF FLOOR. 4 60T 64A JACKS-STABILIZING,ELECT W/O 60T CABLE PORTABLE SATELLITE DISH INPUT CONNECTIONS WATER PUMP 01-Feb-2018

Upload: others

Post on 19-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 8 7 6 5 4 3 1 2COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC. ONE-PLACE (X.X) C 7 WIRING INSTL-BODY,12V 1 OF 6 000120921 / 32287801000 3 1.5 0.50 1 X-X FOR ELECTRICAL CALLOUTS SEE DWG NO

VIEW AA

1.

265

AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODEREQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR108046 AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATEFOR INSTALLATION.

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

1B1

1B1

NOTES:

265

SWITCHDETAIL DJ

PLATE-WALL149557-03-CHTSCREWG39-08-12U (2)

PORT-SOLAR,SINGLE191558-01-000SCREWG39-10-12U (4)

PANEL-SERVICE000017108 / 313328-01-CHTSCREWG39-08-12U (4)

WIRE ASM-TANK,MAIN HOLDING151317-04-000

WIRE ASM-HEATER,TANKS191919-01-000

WIRE ASM-TANK,AUX HOLDING151316-04-000

AA

3

GROMMET114208-06-000

PSSLED-2

DRAINAGE SYSTEM/HEAT-PREWIRE23R

DRAINAGE SYSTEM-HEATED23T

SPLICE YELLOW TO RED AND WHITE TO BLACK.2

23T

2

23R

GROMMET023942-01-000

3 WIRE PASSES THROUGH FLOOR IN THIS AREA.

3

HARNESS-SLIDEOUT MOTOR191660-01-000

HARNESS-SLIDEOUT MOTOR191660-01-000

3

UNSPECIFIED TOLERANCES: MATERIAL:

C

D

1

TWO-PLACE (X.XX)

DSNR:

DESCRIPTION:

8

2

B

ALL DIMENSIONS ARE IN MILLIMETERSDFTR:

6

A

6

FIRST USED:

A

REV

WHOLE DIM (X)

D

REF:

8

ITEM/PART NO:

4

WEIGHT: (LBS)

SHEET:

7

B

2

4

REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES

ANGLE

5

5

13

COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC.

ONE-PLACE (X.X)

C

7

WIRING INSTL-BODY,12V

1 OF 6 000120921 / 32287801000

3

1.5

0.50

1

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

18 423A

VIEW AB

AB

JACKS-STABILIZING, ELECTRIC64A

PANEL-SWITCH000028367 / 316237-01-CHTSWITCH-ROCKER108357-06-000 (2)ACTUATOR108356-01-CHT (2)LABEL-STABILIZER000007799 / 310651-01-CHT

138

INSIDE WALL OFCOMPARTMENT

SCREWG39-08-12U (2)

4

WITH LAMP TO BE MOUNTED ON UNDERSIDE OF FLOOR.4 60T

64A

JACKS-STABILIZING,ELECT W/O60T

CABLEPORTABLE

SATELLITEDISH

INPUT CONNECTIONS

WATERPUMP

01-Feb-2018

Page 2: 8 7 6 5 4 3 1 2COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC. ONE-PLACE (X.X) C 7 WIRING INSTL-BODY,12V 1 OF 6 000120921 / 32287801000 3 1.5 0.50 1 X-X FOR ELECTRICAL CALLOUTS SEE DWG NO

SPEAKER171547-01-CHT (3)SPACER178966-01-000 (3)SCREWG11-08-16U (12)

LIGHT-TAPE,LED187693-21-CHT

SWITCHDETAIL DL

WIRE ASM-HEATER,RELAY153891-01-000

RELAY063912-02-000

NOTES:

AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODEREQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR108046 AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATEFOR INSTALLATION.

WIRE PASSES THROUGH FLOOR IN THIS AREA.

1.

2 CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265

GROMMET114208-06-000

USB-CHARGER188312-01-000

XXZ

JY

YYF

JA

Sw

itch

Ba

ttery

Gro

und

Lo

ad

WATER PUMP CONTROL

DETAIL BA

PART OF WIRE ASM-RIGHT

23T23R

23T23R

23R DRAINAGE SYSTEM/HEAT-PREWIRE

23T DRAINAGE SYSTEM-HEATED

PSSLED-22

DROP TOSERVICE PANEL

PSSLED-2

THERMOSTAT-FURNACE115764-01-CHT

WIRE ASM-SLIDEOUT,OVHD000121099 / 322942-01-000

2

USB-CHARGER188312-01-000

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,12V

000120921 / 32287801000 2 OF 6

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

TO RIGHT SIDE

RECEPTACLE-12V132958-01-000

RECEPTACLE-12V132958-01-000

LIGHT-TAPE, LED187693-32-CHT

3

3

SWITCH ON LAMP TO BE ORIENTATED TO THE REAR.3

01-Feb-2018

Page 3: 8 7 6 5 4 3 1 2COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC. ONE-PLACE (X.X) C 7 WIRING INSTL-BODY,12V 1 OF 6 000120921 / 32287801000 3 1.5 0.50 1 X-X FOR ELECTRICAL CALLOUTS SEE DWG NO

NOTES:

AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODEREQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR108046 AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATEFOR INSTALLATION.

SEE WIRING INSTL-TV/DVD FOR ADDITIONAL INFORMATION.

1.

2 CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265MOUNT MAGNET USING PILOT HOLES IN SCREEN DOOR FRAME.MOUNT WITH MAGNET TOWARD SWITCH.

3

PLATE-WALL(REF)

ADAPTER-COAX082134-01-000 (3)

PLATE-WALL,KEYSTONE175530-04-CHT

PLATE-WALL,COAX EXTERIOR183638-01-CHT

GROMMET114208-06-000

RELAY063912-02-000 (2)

68T

LOAD CENTER(REF)

68T

SPEAKER171547-01-CHT (2)SCREWG39-10-12U (8)

PLATE-WALL,KEYSTONE175530-04-CHT

68X

USB-CHARGER188312-01-000

PLATE-WALL149557-13-CHT

SWITCH(REF)

68X

WIRE ASM-SOLAR PANEL191761-02-000

2-PIN HSG FROMWIRE ASM-CHASSISCIRCUITS:LLL,LLK

SWITCHDETAIL DE

6-PIN HSG FROMFRONT LEFT ROOMFRONT MOTOR(YEL)

CA

DH

SWITCHESDETAIL DF

SWITCHESDETAIL DD

JP TOSTOVE GROUND

LPGD

6-PIN HSG FROMFRONT LEFT ROOMREAR MOTOR(GRN)

2-PIN HSG FROMWIRE ASM-CHASSISCIRCUIT:DDJ

4-PIN HSG FROMWIRE ASM-CHASSISCIRCUITS:ABY,ABZ,DR,DU

VIEW CA(COVER REMOVED)

4 MOUNT SWITCH AND SPACER TO BLOCK ON JAMB.ADJUST HEIGHT TO MATCH MAGNET.

2

2

TO LEFT SIDE

WIRE ASM-RIGHT000121089 / 322930-01-000

TO FURNACE

PSSLED-22

PSSLED-2

52

DOOR SWITCHDETAIL CB

2

4

ROUTE WIRESTHRU HOLE

SWITCH/MAGNET-STEP,ELECTRIC116995-03-000SCREWG11-06-06U (2)

JAMB-DOOR

3

GROMMET8386-01-000

DETAIL CB

CABLES AND COAX CONNECT TO WALL PLATES WITHOR TO COUPLERS AND ADAPTORS WITH

5

LIGHT-TAPE, LED187693-21-CHT

2

PRLED-2

2

SPEAKER171547-01-CHTSPACER178966-01-000SCREWG11-08-16U (4)

TV - BEDROOM

PRLED-2

68T

SWITCHDETAIL DB

15,12 PIN HSGSCOAX (RED,YEL,GLD)TO WIRE ASM-ROOF

SWITCHDETAIL DA

CABLE-HDMICABLE-RCA,3-WAYCOAX (GRN)FROM WIRE ASM-ROOF

SWITCHDETAIL DC

TV - BEDROOM WITHOUT

CONTROL-WATER PUMP176001-01-000DETAIL BA

TO WATER HEATER

WIRE ASM-TANK,WATER151316-02-000

15,6 PIN HSGSTO WIRE ASM-CHASSIS

CC

VIEW CC

CONTROL-SLIDEOUT189400-01-000

COVER-ELECTRICAL194965-01-CHTLABEL-SLIDEOUT CTL098379-09-000CONTROL-SLIDEOUTVIEW CA

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,12V

000120921 / 32287801000 3 OF 6

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

WASHER-LOCK000007554 / 310611-01-000 (2) 6

REMOVE SCREWS FROM MAGNET SWITCH TO INSTALLLOCK WASHER AND RING TERMINALS.

6

RELAY063912-02-000

RECEPTACLE-12V132958-01-000

LIGHT-TAPE, LED187693-37-CHT

SWITCH ON LAMP TO BE ORIENTATED TO THE REAR.7

7

7

01-Feb-2018

Page 4: 8 7 6 5 4 3 1 2COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC. ONE-PLACE (X.X) C 7 WIRING INSTL-BODY,12V 1 OF 6 000120921 / 32287801000 3 1.5 0.50 1 X-X FOR ELECTRICAL CALLOUTS SEE DWG NO

SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)

DETAIL DB

JCPD

SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)

DETAIL DC

JDPE

SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)

DETAIL DE

JDPC

SWITCH-ROCKER135740-01-CHT (3)SWITCH-BASE135741-03-CHTSWITCH-BEZEL135742-03-CHTSCREWG11-08-08U (4)

DETAIL DD

JCPK

JDA

JCPJ

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

DRAINAGE SYSTEM-HEATED

DRAINAGE SYSTEM/HEAT-PREWIRE

2651B1

1B1

265

23T

23R

DETAIL DA

SWITCH-ROCKER108357-21-000ACTUATOR-SWITCH108356-23-CHTPLATE-SWITCH144363-02-CHTSCREWG11-06-10U (2)

DETAIL DF

VIEW DH

DETAIL DK

SWITCH-ROCKER108357-01-000ACTUATOR-SWITCH108356-22-CHTCIRCUITSFFD,FFT

SWITCH-ROCKER108357-06-000ACTUATOR-SWITCH108356-12-CHTCIRCUITS FFN,FFP,FFR

SWITCH-ROCKER108357-14-000ACTUATOR-SWITCH108356-28-CHTCIRCUITS RS,ZZK,NC

PLATE-SWITCH000022055 / 314395-01-CHTSCREWG11-06-10U (4)

SWITCH-BATTERY108357-18-000ACTUATOR-SWITCH108356-19-CHTCIRCUITS LH,LG,LJ-1,JC,NCWIRE ASM-THERMISTOR186796-01-000

SWITCH-ROCKER108357-19-000CIRCUITS ER,ES

1

1 SEE WIRING INSTL-CHASSIS FOR ADDITIONAL INFORMATION.

NOTES:

SWITCH-ROCKER108357-21-000ACTUATOR-SWITCH108356-23-CHT

DETAIL DJ

SOLAR PANELCONNECTION

BATTERYCONNECTION

(8 GRN) (GLD)

(8 BLK) (GLD)

WIRE ASM-SOLAR CONTROLLER

WIRE ASM-SOLAR PANEL

(8 BLK) (YEL)

(8 GRN) (YEL)

PG

SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)

DETAIL DL

JC

SWITCH-ROCKER108357-18-000ACTUATOR-SWITCH108356-31-CHTCIRCUITSHHH,DT,HHG

LABEL-WARNING,SLIDEOUT116549-02-000

LABEL-SWITCH,HTR,HOLDING TK134563-01-CHT SWITCH

DETAIL DG

23R

CONTROL-CHARGE,SOLAR 30 AMP191278-01-000SCREWG11-08-08U (2)DETAIL DK23T

PANEL-MONITOR,LCD175724-01-000SCREWG11-08-08U (4)

LABEL-SWITCH,HTR,HOLDING TK(REF)

SWITCH-ROCKER135740-06-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)

DETAIL DG

JAHRJP

HOLDING TANK HEATERTURN OFF When Not In Use

SEE OPERATORS MANUAL

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,12V

000120921 / 32287801000 4 OF 6

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

SWITCH-ROCKER108357-14-000ACTUATOR-SWITCH108356-03-000CIRCUITS AES,AET,NC

REMOTE PANEL-INVERTER000037772 / 318694-01-CHTCABLE-DATA000038250 / 318769-01-000SCREWG11-06-08U (2)SWITCH-BLANK138253-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)

INVERTER-DC/AC, 1000 WATT401

401

40A

PLATE-SWITCH144363-02-CHT

Battery

LevelsWater

Pump

Stop

ONE PLACEGenSet

Tank

Start

Meter

HeaterL.P.

HeaterElectric

WARNING

116549-02G

CRUSH HAZARD. Keep people and objectsclear of the inside and outside of the slideoutroom when operating. Failure to comply couldresult in death or serious injury.

TURN OFF When Not In Use

SEE OPERATORS MANUAL

HOLDING TANK HEATER

ON

AWNING

OFF IN

OUT

AWNING

WATERPUMP

WATERPUMP

01-Feb-2018

Page 5: 8 7 6 5 4 3 1 2COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC. ONE-PLACE (X.X) C 7 WIRING INSTL-BODY,12V 1 OF 6 000120921 / 32287801000 3 1.5 0.50 1 X-X FOR ELECTRICAL CALLOUTS SEE DWG NO

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,12V

000120921 / 32287801000 5 OF 6

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

CONVERTER-45 AMP184353-01-000SCREWG67-10-12U (3)

PART OFWIRE ASM-GROUNDS

TO CHASSIS GND

DRAINAGE SYSTEM/HEAT-PREWIRE23R

NOTES:

JG14 YEL(12V OUTLETS)

JC14 YEL(LAMPS)

NM12 YEL(TANK HEATERS)

JE14 YEL(AUDIO/VISUAL)

1 SEE WIRING INSTL-CHASSIS FOR ADDITIONAL INFORMATION.

"T"PART OF

WIRE ASM-CHASSIS

JD14 YEL(LAMPS)(SATELLITE PREP)

WB16 YEL(LP/CO DETECTOR)

JB14 YEL(FURNACE)(VENTS)

"J" FROMWIRE ASM-CHASSIS

EXTERNALGROUND BAR

LLK10 YEL(SLIDEOUT)

23T

"M"PART OF WIRE ASM-RIGHT

JA12 YEL(WATER PUMP)(MONITOR PANEL)(ISOLATED CIRCUIT)

23T

DRAINAGE SYSTEM-HEATED

P10 YEL(REFRIGERATOR)

1

FFD12 YEL(AWNING)

"L"PART OF WIRE ASM-RIGHT

23R

FUSE62901-08-000(30 AMP)

FUSE62901-05-000 (7)(15 AMP)

FUSE62901-05-000(15 AMP)

FUSE62901-06-000(20 AMP)

FUSE62901-02-000(5 AMP)

23T23R

15

15

15

15

30

5

15

15

15

15

2011

AMPS

DC BRANCH CIRCUIT

10

3

AMPS

9

30 AMP MAX

12

MAIN

AMPS

8

AMPS

30 AMP MAX AMPS

AMPS

5

30 AMP MAX

1

2

AMPS

4

7

AMPS

6

AMPS

AC BRANCH CIRCUIT

AMPS

AMPS

AMPS

30 AMP MAX

01-Feb-2018

Page 6: 8 7 6 5 4 3 1 2COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC. ONE-PLACE (X.X) C 7 WIRING INSTL-BODY,12V 1 OF 6 000120921 / 32287801000 3 1.5 0.50 1 X-X FOR ELECTRICAL CALLOUTS SEE DWG NO

NOTES:

SEE ANTENNA INSTALLATION MANUAL FORCORRECT INSTALLATION PROCEDURE.

WRAP BRACKET LEGS AROUND ANTENNA BASE.2

1

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265

1130

1 PORT-SOLAR,3 POSITION191277-01-CHTDETAIL FC

636

DETAIL FB

(2)308

DETAIL FB

PANEL-SOLAR(REF)

PORT-SOLAR(REF)

DETAIL FC

WIRE ASM-SOLAR PANEL

8 BLK TO EMPTYPOST ON30A BREAKER

8 GRN TO GROUND STUD(STACK GROUND WIRES)

PORT-SOLAR(REF)

BRACKET ANTENNAGROUND

NDFROM WIRE ASM-ROOF

VIEW FA

2

PRLED-49

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,12V

000120921 / 32287801000 6 OF 6

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

ANTENNA-TV ROOF000039180 / 318992-01-CHTSCREWG67-10-12U (6)

1440

ANTENNA-RADIO,16 RUBBER090944-01-000BRACKET-ANTENNA GROUND147741-01-CHTVIEW FA

PANEL-SOLAR 100 WATT, FLEXIBLE000131101 / 325665-01-000 (2)WASHER077071-01-000 (12)SCREW000G39-10-16U (12)

294

01-Feb-2018