8 t2 sc series

Upload: antony-ve

Post on 08-Aug-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/22/2019 8 t2 Sc Series

    1/16

    Sub-Compact Nitrogen Gas Springs

    T2 SC Series

    Ninemodelsincludingaone-inchdiameterspringwith4250N/955lb.contactforce.

    Strokelengthsto50mm/1.97in. Idealforheavygaugeblanking,piercing,stripping,shallowdepthdrawing,embossingand

    knock-outapplications.

    Boresealdesigndelivershighforceinsmallarea.

    APPROVED

    97/23/EC

  • 8/22/2019 8 t2 Sc Series

    2/162HysonProducts2009

    1-800-876-4976440/526-5900FAX:440/526-6807www.hysonproducts.com

    Table of Contents

    PageProduct Specifcations ............................................................................... 3

    Service and Repair Kits ............................................................................. 3

    Ordering Options ....................................................................................... 3

    T2SC-420 .................................................................................................. 4

    T2SC-740 .................................................................................................. 5

    T2SC-1000 & T2SC-1800 ......................................................................... 6

    T2SC-2900 ................................................................................................ 8

    T2SC-4700 & T2SC-7500 ....................................................................... 10

    T2SC-11800 & T2SC-18300 .................................................................... 12

    Hosed System Mode ............................................................................... 14

  • 8/22/2019 8 t2 Sc Series

    3/16

    The T2 SC Series

    3HysonProducts2009

    1-800-876-4976440/526-5900FAX:440/526-6807www.hysonproducts.com

    Note:AllT2SCgasspringsshippedatmaximumchargepressureunlessotherwisespecied.

    Note:Flangesorderedseparately.

    Ordering Options

    T2SC-4700 X 50 2175psi

    Model Stroke Charge Pressure

    T2SC-420 See Max:150bar/2175psi

    T2SC-740 Dimensional

    T2SC-1000 Information

    T2SC-1800 Charts T2SC-2900

    T2SC-4700 T2SC-7500 T2SC-11800 T2SC-18300

    Product Specifcations

    PressureMedium..................................................................................................................Nitrogen

    Max.ChargingPressure.......................................................................................... 150bar/2175psi

    Min.ChargingPressure.............................................................................................. 25bar/360psi

    OperatingTemperature.........................................................................................0-80C/32-176F

    ForceIncreasebyTemperature...........................................................0.3%perC/0.009%perF

    RecommendedMax.Strokes/Min........................................ ~50-100(modelandstrokedependent)

    MaximumPistonRodVelocity........................................................................ 30m/min./98ft./min.

    MaximumUtilizedStroke..........................................................................................................100%

    InletValve.................................................................................. 4018112(T2SC-420through1000)

    56-072-5500(T2SC-1800through18300)

    Charge Fittings

    Gas Spring Charge Fitting

    T2SC-420 T2-770-T3

    T2SC-740T2-770-M6

    T2SC-1000

    T2SC-1800

    T2-770-G1/8-P

    T2SC-2900

    T2SC-4700

    T2SC-7500

    T2SC-11800

    T2SC-18300

    Repair Kits

    Gas Spring Repair Kit

    T2SC-420 Notrepairable

    T2SC-740 Notrepairable

    T2SC-1000 T2SCSK-1000

    T2SC-1800 T2SCSK-1800

    T2SC-2900 T2SCSK-2900

    T2SC-4700 T2SCSK-4700

    T2SC-7500 T2SCSK-7500

    T2SC-11800 T2SCSK-11800

    T2SC-18300 T2SCSK-18300

  • 8/22/2019 8 t2 Sc Series

    4/164

    HysonProducts20091-800-876-4976440/526-5900FAX:440/526-6807www.hysonproducts.com

    Note:Alldimensionsarenominal.Datashownaretypical.Actualdataforanyparticularunitmayvary.

    T2SC-420

    11.5 mm0.45 in.

    5 mm

    0.20 in.

    12 mm

    0.47 in.

    24.9M6 charge port,depth 5 mm/0.20 in.mm 0.05

    1 mm0.04 in.

    0.98 in.

    5 mm0.20 in.

    L

    Y

    S

    7

    50 mm/1.97 in.

    34 mm/1.34 in.

    38 mm/1.50 in.

    30 mm1.18 in.

    18 mm0.71 in.

    16 mm0.63 in.

    9 mm0.35 in.

    9 mm0.35 in.

    FCRPartNo.T2-180-FCR

    T2SC-420 Dimensional Inormation

    Order NumberStroke S Contact Force Full Stroke Force Y L

    mm in. N lbs. N lbs. mm in. mm in.

    T2SC-420X6 6 0.24

    4250 955

    7000 1575 56 2.20 50 1.97

    T2SC-420X10 10 0.39 6900 1550 70 2.76 60 2.36

    T2SC-420X16 16 0.63 6900 1550 91 3.58 75 2.95

    T2SC-420X25 25 0.98 6900 1550 120 4.72 95 3.74

    T2SC-420X32 32 1.26 7600 1700 140 5.51 108 4.25

    T2SC-420X40 40 1.57 7600 1700 165 6.50 125 4.92

    T2SC-420X50 50 1.97 7600 1700 195 7.68 145 5.71

    Note:HysonrecommendsthatT2gasspringsarebackedupatalltimes.Strokelengthsofgreaterthan25mmshouldbebaseorangemounted.

    M6 charge port

    Note:Allangesareorderedseparately.

  • 8/22/2019 8 t2 Sc Series

    5/165

    HysonProducts20091-800-876-4976440/526-5900FAX:440/526-6807www.hysonproducts.com

    T2SC-740

    FCPartNo.T3-350-FC

    32.1 mm 0.05

    1.26 in.

    11.5 mm

    0.45 in.

    10.5 mm

    0.41 in.

    L

    Y

    1 mm

    0.04 in.

    S

    20 mm

    0.79 in.

    15 mm0.59 in.

    M6 (2x)5.5 mm deep0.22 in.

    M6 Charge Port

    FCSPartNo.FCS-32

    7 mm0.28 in.

    Body

    17 mm0.67 in.

    35 mm/1.38 in.

    49.5 mm/1.95 in.

    45 mm/1.77 in.

    + 1.0

    + 0.5

    9 mm

    0.35 in.

    Body + 1.0+ 0.5

    16 mm0.63 in.

    9 mm0.35 in.

    7 mm

    0.28 in.

    35 mm/1.38 in.

    49.5 mm/1.95 in.

    60 mm/2.36 in.

    T2SC-740 Dimensional Inormation

    Order NumberStroke S Contact Force Full Stroke Force Y L

    mmin.

    Nlbs.

    Nlbs.

    mmin.

    mmin.

    T2SC-740X6 6 0.24

    7400 1700

    9800 2200 63 2.48 57 2.24

    T2SC-740X10 10 0.39 10000 2250 75 2.95 65 2.56

    T2SC-740X16 16 0.63 11000 2500 93 3.66 77 3.03

    T 2SC -740X 25 25 0.98 12000 2700 120 4.72 95 3.74

    T 2SC -740X32 32 1.26 12000 2700 140 5.51 108 4.25

    T 2SC -740X4 0 4 0 1.57 12000 2700 165 6.50 125 4.92

    T 2SC-74 0X5 0 50 1.97 12000 2700 195 7.68 145 5.71

    Note:HysonrecommendsthatT2gasspringsarebackedupatalltimes.Strokelengthsofgreaterthan25mmshouldbebaseorangemounted.

    Note:Allangesareorderedseparately.

  • 8/22/2019 8 t2 Sc Series

    6/166

    HysonProducts20091-800-876-4976440/526-5900FAX:440/526-6807www.hysonproducts.com

    Note:Alldimensionsarenominal.Datashownaretypical.Actualdataforanyparticularunitmayvary.

    T2SC-1000 & 1800

    B

    A

    S

    0.5 mm0.02 in.

    E

    M6 x 1 (2x)6.5 mm deep

    0.26 in.

    D

    Charge portT2SC-1000: M6T2SC-1800: G 1/8"

    Y

    L

    C

    C

    FCPartNo.T2-250-FCPartNo.T2-750-FC

    a

    bc

    d

    Body + 0.5+ 2.0

    e

    e

    f

    f

    For model Order No. a b c d e f

    mm in. mm in. mm in. mm in. mm in. mm in.

    T2SC-1000 T2-250-FC 68 2.68 56.5 2.22 40 1.57 7 0.28 9 0.35 15 0.59

    T2SC-1800 T2-750-FC 95 3.74 80 3.15 56.5 2.22 9 0.35 13 0.51 21 0.83

    T2SC-1000 Dimensional Inormation

    Order NumberStroke S Contact Force Full Stroke Force Y L A B C D E

    mm in. N lbs. N lbs. mm in. mm in. mm in. mm in. mm in. mm in. mm in.

    T 2S C-10 00X6 6 0.24

    10600 2400 16000 3600

    61 2.40 55 2.17

    37.9 1.49 20 0.79 10.5 0.41 17 0.67 6.5 0.26

    T2SC-1000X10 10 0.39 78 3.07 68 2.68

    T2SC-1000X16 16 0.63 100 3.94 84 3.31

    T2SC-1000X25 25 0.98 135 5.31 110 4.33

    T2SC-1000X32 32 1.26 167 6.57 135 5.31

    T2SC-1000X40 40 1.57 195 7.68 155 6.10

    T2SC-1000X50 50 1.97 230 9.08 180 7.09

    T2SC-1800 Dimensional Inormation

    Order NumberStroke S Contact Force Full Stroke Force Y L A B C D E

    mm in. N lbs. N lbs. mm in. mm in. mm in. mm in. mm in. mm in. mm in.

    T 2S C-18 00X 6 6 0.24

    18000 4050

    25000 5625 66 2.60 60 2.36

    50.2 1.98 30 1.18 14.5 0.57 26 1.02 6.5 0.26

    T2SC-1800X10 10 0.39 26000 5850 80 3.15 70 2.76

    T2SC-1800X16 16 0.63 26000 5850 106 4.17 90 3.54

    T2SC-1800X25 25 0.98 27000 6075 135 5.31 110 4.33

    T2SC-1800X32 32 1.26 27000 6075 162 6.38 130 5.12

    T2SC-1800X40 40 1.57 28000 6300 190 7.48 150 5.91

    T2SC-1800X50 50 1.97 29000 6525 220 8.66 170 6.69

    Note:HysonrecommendsthatT2gasspringsarebackedupatalltimes.Strokelengthsofgreaterthan25mmshouldbebaseorangemounted.

  • 8/22/2019 8 t2 Sc Series

    7/167

    HysonProducts20091-800-876-4976440/526-5900FAX:440/526-6807www.hysonproducts.com

    T2SC-1000 & 1800

    SP 1800PartNo.T2SC-1800-SP

    SP 1000PartNo.T2SC-1000-SP

    BFPartNo.T2SC-1000-BFPartNo.T2SC-1800-BF

    FCSPartNo.T2-250-FCSPartNo.T2-750-FCS

    38 mm1.50 in.

    20 mm0.79 in.

    10.5 mm0.41 in.

    G 1/8 port

    26 mm1.20 in.

    B

    B

    M6 (2x)

    45

    11.5 mm0.45 in.

    B - B

    4 mm0.16 in.

    4 mm0.16 in.

    c

    d

    b

    a

    c

    a

    b

    Body + 0.5+ 2.0

    d

    e

    e

    f

    f

    261.20 in.

    B

    B

    M6 (4x)

    G 1/8 port

    45

    7 mm0.28 in.

    50.2 mm1.98 in.

    20 mm0.79 in.

    10.5 mm0.41 in.

    11.5 mm0.45 in.

    B - B

    8 mm0.31 in.

    For model Order No.a b c d

    mm in. mm in. mm in. mm in.

    T2SC-1000 T2SC-1000-BF 52 2.05 40 1.57 7 0.28 14.5 0.57

    T2SC-1800 T2SC-1800-BF 70 2.76 56.5 2.22 9 0.35 19.5 0.77

    For model Order No. a b c d e f

    mm in. mm in. mm in. mm in. mm in. mm in.

    T2SC-1000 T2-250-FCS 56.5 2.22 52 2.05 40 1.57 7 0.28 9 0.35 15 0.59

    T2SC-1800 T2-750-FCS 80 3.15 70 2.76 56.5 2.22 9 0.35 13 0.51 21 0.83

    Note: TheT2SC-1000-SPadapterplatehasnovalveandcanbepressurizedonlythroughahosedsystem.Itisdelivereduncharged.ItcanbeusedforoldermodelT2SCgasspringsaswell.

    Note:Allangesareorderedseparately.

    Note:TheT2SC-1800-SPadapterplatehasnovalveandcanbepressurizedonlythroughahosedsystem.Itisdelivereduncharged.ItcanbeusedforoldermodelT2SCgasspringsaswell.

  • 8/22/2019 8 t2 Sc Series

    8/168

    HysonProducts20091-800-876-4976440/526-5900FAX:440/526-6807www.hysonproducts.com

    Note:Alldimensionsarenominal.Datashownaretypical.Actualdataforanyparticularunitmayvary.

    T2SC-2900

    63.2 mm 0.12.49 in.

    45 mm1.77 in.

    1 mm0.04 in.

    11 mm (2x)0.43 in.

    9 mm (2x)0.35 in.

    34 mm1.34 in.

    Y

    L

    S

    19 mm0.75 in.

    G1/8" charge port

    18 mm0.71 in.

    M8x1.25

    (2x)

    9mmdeep

    0.35in.

    T2SC-2900 Dimensional Inormation

    Order NumberStroke S Contact Force Full Stroke Force Y L

    mm in. N lbs. N lbs. mm in. mm in.

    T2SC-2900X10 10 0.39

    29500 6650

    38500 8650 85 3.35 75 2.95

    T2SC-2900X16 16 0.63 41000 9225 103 4.06 87 3.43T2SC-2900X25 25 0.98 43000 9675 130 5.12 105 4.13

    T2SC-2900X32 32 1.26 44200 9950 150 5.91 118 4.65

    T2SC-2900X40 40 1.57 45200 10175 175 6.89 135 5.31

    T2SC-2900X50 50 1.97 45800 10300 205 8.07 155 6.10

    Note: HysonrecommendsthatT2gasspringsarebackedupatalltimes.Strokelengthsofgreaterthan25mmshouldbebaseorangemounted.

  • 8/22/2019 8 t2 Sc Series

    9/169

    HysonProducts20091-800-876-4976440/526-5900FAX:440/526-6807www.hysonproducts.com

    T2SC-2900

    SPPartNo.T2SC-2900-SP

    FCSPartNo.T3-1500-FCS

    Body

    11 mm0.43 in.

    27 mm

    1.06 in.

    73.5 mm/2.89 in.

    104 mm/4.09 in.

    90 mm/3.54 in.

    16 mm0.63 in.

    + 0.5+ 2.0

    34 mm1.34 in.

    M8 (4x)

    45

    7 mm0.28 in.

    20 mm0.79 in.

    10.4 mm0.41 in.

    63.2 mm

    2.49 in.

    G 1/8 port

    11.5 mm0.45 in.

    B - B

    8 mm0.31 in.

    Note:TheT2SC-2900-SPadapterplatehasnovalveandcanbepressurizedonlythroughahosedsystem.Itisdelivereduncharged.ItcanbeusedforoldermodelT2SCgasspringsaswell.

    Note:Allangesareorderedseparately.

  • 8/22/2019 8 t2 Sc Series

    10/1610

    HysonProducts20091-800-876-4976440/526-5900FAX:440/526-6807www.hysonproducts.com

    Note:Alldimensionsarenominal.Datashownaretypical.Actualdataforanyparticularunitmayvary.

    T2SC-4700 & 7500

    T2SC-4700 Dimensional Inormation

    Order Number

    Stroke S Contact Force Full Stroke Force Y L A B C D E

    mm in. N lbs. N lbs. mm in. mm in. mm in. mm in. mm in. mm in. mm in.

    T2SC-4700X10 10 0.39

    47000 10600

    67000 15100 80 3.15 70 2.76

    75.2 2.96 50 1.97 18 0.71 40 1.57 9 0.35

    T2SC-4700X16 16 0.63 66000 14900 106 4.17 90 3.54

    T2SC-4700X25 25 0.98 68000 15300 135 5.31 110 4.33

    T2SC-4700X32 32 1.26 67000 15100 167 6.57 135 5.31

    T2SC-4700X40 40 1.57 67000 15100 200 7.87 160 6.30

    T2SC-4700X50 50 1.97 67000 15100 240 9.45 190 7.48

    T2SC-7500 Dimensional Inormation

    Order NumberStroke S Contact Force Full Stroke Force Y L A B C D E

    mm in. N lbs. N lbs. mm in. mm in. mm in. mm in. mm in. mm in. mm in.

    T2SC-7500X10 10 0.39

    75000 17000

    104000 23400 90 3.54 80 3.15

    95.2 3.75 55 2.17 21 0.83 52 2.05 9 0.35

    T2SC-7500X16 16 0.63 104000 23400 116 4.57 100 3.94

    T2SC-7500X25 25 0.98 109000 24500 145 5.71 120 4.72

    T2SC-7500X32 32 1.26 105000 23600 182 7.17 150 5.91

    T2SC-7500X40 40 1.57 107000 24100 210 8.27 170 6.69

    T2SC-7500X50 50 1.97 106000 23850 255 10.24 205 8.07

    Note: HysonrecommendsthatT2gasspringsarebackedupatalltimes.Strokelengthsofgreaterthan25mmshouldbebaseorangemounted.

    B

    A

    S

    0.5 mm0.02 in.

    E

    D

    G 1/8 charge port

    M8 (4x)

    C

    C

    Y

    L

  • 8/22/2019 8 t2 Sc Series

    11/1611

    HysonProducts20091-800-876-4976440/526-5900FAX:440/526-6807www.hysonproducts.com

    BFPPartNo.T2SC-4700-BFPPartNo.T2SC-7500-BFP

    FKPartNo.T2-1500-FKPartNo.T2-3000-FK

    T2SC-4700 & 7500

    SP 7500PartNo.T2-7500-SP

    SP 4700PartNo.T2SC-4700-SP

    Note:Allangesareorderedseparately.

    Body + 0.5+ 2.0

    a

    bc

    d

    e

    e

    f

    f

    c

    d

    b

    a

    45

    B B

    M8 (4x)

    B - B

    Valve PN 56-072-5500

    G 1/8 port

    40 mm1.57 in.

    7 mm0.28 in.

    20 mm0.79 in.

    10.5 mm0.41 in.

    75.2 mm

    2.96 in.

    11.5 mm0.45 in.

    8 mm

    0.31 in.

    M8 (4x)

    45

    B B

    B - B

    Valve PN 56-072-5500

    G 1/8 port

    52 mm2.05 in.

    7 mm0.28 in.

    20 mm0.79 in.

    10.5 mm0.41 in.

    95.2 mm

    3.75 in.

    11.5 mm0.45 in.

    8 mm0.31 in.

    For model Order No.a b c d

    mm in. mm in. mm in. mm in.

    T2SC-4700 T2SC-4700-BFP 90 3.54 73.5 2.89 11 0.43 24.5 0.96

    T2SC-7500 T2SC-7500-BFP 110 4.33 92 3.62 13 0.51 27.5 1.08

    For model Order No. a b c d e f

    mm in. mm in. mm in. mm in. mm in. mm in.

    T2SC-4700 T2-1500-FK 104 4.09 90 3.54 73.5 2.89 11 0.43 16 0.63 26 1.02

    T2SC-7500 T2-3000-FK 130 5.12 110 4.33 92 3.62 13.5 0.53 18 0.71 30 1.18

    Note: TheT2SC-7500-SPcanbeusedforoldermodelT2SCgasspringsaswell.Note:TheT2SC-4700-SPcanbeusedforoldermodelT2SCgasspringsaswell.

  • 8/22/2019 8 t2 Sc Series

    12/1612

    HysonProducts20091-800-876-4976440/526-5900FAX:440/526-6807www.hysonproducts.com

    Note:Alldimensionsarenominal.Datashownaretypical.Actualdataforanyparticularunitmayvary.

    T2SC-11800 & 18300

    FCPartNo.T2-5000-FCPartNo.T2-7500-FC

    B

    A

    S

    0.5 mm0.02 in.

    E

    D

    G 1/8 charge port

    M10 (4x)

    C

    C

    L

    Y

    For model Order No. a b c d e f

    mm in. mm in. mm in. mm in. mm in. mm in.

    T2SC-11800 T2-5000-FC 175 6.89 155 6.10 109.5 4.31 13.5 0.53 21 0.83 33 1.30

    T2SC-18300 T2-7500-FC 220 8.66 195 9.68 138 5.43 17.5 0.69 27 1.06 38 1.50

    T2SC-11800 Dimensional Inormation

    Order Number Stroke S Contact Force Full Stroke Force Y L A B C D E

    mm in. N lbs. N lbs. mm in. mm in. mm in. mm in. mm in. mm in. mm in.

    T2SC-11800X10 10 0.39

    118000 26500

    155000 34900 100 3.94 90 3.54

    120.2 4.73 70 2.76 22.5 0.89 68 2.68 11 0.43

    T2SC-11800X16 16 0.63 158000 35500 126 4.96 110 4.33

    T2SC-11800X25 25 0.98 170000 38200 155 6.10 130 5.12

    T2SC-11800X32 32 1.26 164000 36900 187 7.36 155 6.1

    T2SC-11800X40 40 1.57 165000 37100 220 8.66 180 7.09

    T2SC-11800X50 50 1.97 166000 37300 260 10.24 210 8.27

    T2SC-18300 Dimensional Inormation

    Order NumberStroke S Contact Force Full Stroke Force Y L A B C D E

    mm in. N lbs. N lbs. mm in. mm in. mm in. mm in. mm in. mm in. mm in.

    T2SC-18300X10 10 0.39

    183000 41100

    235000 52800 110 4.33 100 3.94

    150.2 5.91 90 3.54 24.5 0.96 90 3.54 11 0.43

    T2SC-18300X16 16 0.63 252000 56600 136 5.35 120 4.72

    T2SC-18300X25 25 0.98 254000 57100 165 6.50 140 5.51

    T2SC-18300X32 32 1.26 251000 56400 197 7.76 165 6.5

    T2SC-18300X40 40 1.57 250000 56200 235 9.25 195 7.68

    T2SC-18300X50 50 1.97 255000 57300 270 10.63 220 8.66

    Note: HysonrecommendsthatT2gasspringsarebackedupatalltimes.Strokelengthsofgreaterthan25mmshouldbebaseorangemounted.

    a

    b

    c

    d

    Body + 0.5+ 2.0

    e

    ef

    f

  • 8/22/2019 8 t2 Sc Series

    13/1613

    HysonProducts20091-800-876-4976440/526-5900FAX:440/526-6807www.hysonproducts.com

    SP 18300PartNo.T2SC-18300-SP

    SP 11800PartNo.T2SC-11800-SP

    T2SC-11800 & 18300

    B - B

    M10 (4x)

    20

    B B

    Valve PN 56-072-5500

    G 1/8 port

    68 mm2.68 in.

    7 mm0.28 in.

    20 mm0.79 in.

    10.5 mm0.41 in.

    120.1 mm4.73 in.

    20 mm0.79 in.

    8 mm0.31 in.

    BFPartNo.T2SC-11800-BFPartNo.T2SC-18300-BF

    FCSPartNo.T2-5000-FCSPartNo.T2-7500-FCS

    For model Order No.a b c d

    mm in. mm in. mm in. mm in.

    T2SC-11800 T2SC-11800-BF 130 5.12 109.5 4.31 13 0.51 29.5 1.16

    T2SC-18300 T2SC-18300-BF 162 6.38 138 5.43 17.5 0.69 34.5 1.36

    For model Order No. a b c d e f

    mm in. mm in. mm in. mm in. mm in. mm in.

    T2SC-11800 T2-5000-FCS 155 6.10 130 5.12 109.54.31 13.5 0.53 21 0.83 33 1.30

    T2SC-18300 T2-7500-FCS 195 9.68 162 6.38 138 5.43 17.5 0.69 27 1.06 38 1.50

    Note:Allangesareorderedseparately.

    B - B

    M10 (4x)

    20

    B B

    Valve PN 56-072-5500

    G 1/8 port

    90 mm3.54 in.

    20 mm0.79 in.

    10.5 mm0.41 in.

    150.1 mm5.91 in.

    20 mm0.79 in.

    8 mm

    0.31 in.

    8 mm0.31 in.

    e

    c

    a

    b

    Body + 0.5+ 2.0

    d

    f

    f

    e

    Note:TheT2SC-11800-SPcanbeusedforoldermodelT2SCgasspringsaswell. Note: TheT2SC-18300-SPcanbeusedforoldermodelT2SCgasspringsaswell.

    c

    d

    b

    a

  • 8/22/2019 8 t2 Sc Series

    14/1614

    HysonProducts20091-800-876-4976440/526-5900FAX:440/526-6807www.hysonproducts.com

    Hosed System Mode

    Hose and Hose Fittings

    ToconnectyourT2SCgasspringinahosedsystemmode,aG1/8servicefittingisrequired.OrderNF-1000-4-G1/8forJICstyleor9106252-Fforo-ringfacesealservicefitting.

    10 mm/0.41 in.

    20 mm/0.79 in.

    Y

    AllT2SCgassprings,excepttheT2SC-420andT2SC-740,canbeusedinahosedsystemwiththesideportadapterplate.Priortohosing,youmustremovetheinletvalve.Whenattachingthesideportadapterplate,specialflangesareavailableforadditionalmountingoptions.

    Inaddition,thesespringswiththeexceptionoftheT2SC-1000canoperateinahosedsystemwithouttheadapterplate

    ifthetoolcanaccommodatehosefittingsfromtheportinthebaseofthespring.Priortohosing,youmustremovetheinletvalve.

    Hosed System Mount - SP

    Bottom Flanges for use with side port adapter plate only

    Hose System Components Summary

    10 mm

    0.39 in.

    24 mm

    0.94 in. 12 mm

    0.47 in.

    7 mm

    0.28 in. 7 mm

    0.28 in.

    A

    A

    B

    A

    C

    B

    Model Adapter Plate

    T2SC-1000 T2SC-1000-SP

    T2SC-1800 T2SC-1800-SP

    T2SC-2900 T2SC-2900-SP

    T2SC-4700 T2SC-4700-SP

    T2SC-7500 T2SC-7500-SP

    T2SC-11800 T2SC-11800-SP

    T2SC-18300 T2SC-18300-SP

    Note: Whenorderingthespring

    withthesideportadapterplate,add

    thesuffixSPafterthespringpart

    number.

    Spring ModelFlange

    Part Number

    A B C

    mm in. mm in. mm in.

    T2SC-1000 T2-250-LM 56.6 2.23 76.6 3.01

    T2SC-1800 T2-750-FFC 75 2.95 56.4 2.22 80 3.15

    T2SC-2900 T3-1500-FFC 100 3.94 73.5 2.89 104 4.09

    T2SC-4700 T2-1500-FFC 100 3.94 73.5 2.89 104 4.09

    T2SC-7500 T2-3000-FFC 120 4.72 92 3.62 130 5.12

    T2SC-11800 T2-5000-FFC 140 5.51 109.5 4.31 155 6.10

    T2SC-18300 T2-7500-FFC 190 7.48 138 5.43 195 7.68

    Note:Theseflangesaresoldseparatelyandshippedunattachedtothespring.

    JIC SystemO-ring Face

    Seal SystemControlpanel CP-N2LG CP-N2LGOR

    Servicefitting(oneperspring

    required)NF-1000-4-G1/8 9106252-F

    Hose ORH-4 ORH-4

    Hoseend SHF-4 ORHF-4

    6springdistributionblock

    TANKMAN-6 TANKMAN-6OR

    12springdistributionblock

    TANKMAN-12 TANKMAN-12OR

    Hose to hose connectors:

    Union NF-1100-4 ORF-1100-4Unionelbow NF-2500-4 ORF-2500-4

    Uniontee NF-3500-4 ORF-3500-4

    Unioncross NF-5500-4 ORF-5500-4

    Hose to spring (serice fitting) connectors:

    Run tee NF-3300-4 ORF-3300-4

    45elbow NF-4500-4

    90elbow NF-2000-4 ORF-2000-4

    Branchtee NF-3000-4 ORF-3000-4

  • 8/22/2019 8 t2 Sc Series

    15/16

  • 8/22/2019 8 t2 Sc Series

    16/16

    10367 Brecksille Road

    Brecksille, OH 44141 USATel: 1-800-876-4976, 440-526-5900

    Fax: 440-526-6807

    Email: [email protected]

    3100 Mainway

    Burlington, ONT L7M 1A3 CanadaTel: 905-331-1311

    Fax: 905-331-1342

    Bld. Rogelio Gonzalez Caballero #500Parque Industrial STIvA Aeropuerto

    Apodaca, NL CP 66600 Mexico

    Tel: 5281 8145-0570

    Fax: 5281 8145-0571

    HysonProducts2009T2SC3M1209

    Nitro-Dyne XP Manifolds

    T2 Standard Gas Springs

    TankerT and TankerS Gas Springs

    T3 Gas Springs

    Adaptive Cams Mechanical Cams

    Di-Dro Adanced Forming

    Controllable Gas Springs

    Mini Gas Springs

    Accessories

    Delay Return Manifolds

    T4 Gas Springs