8 use of pythagorean theorem in #9 single implant case
TRANSCRIPT
BEL 2.2013
Guide Right ™ Use of Pythagorean Theorem in #9 Single Implant Case
3 mm X 30 mm guide post 3 mm guide sleeve
3 mm X 1.5 mm offset guide post 3 mm open guide sleeve Pythagorean Theorem ► Cosine software analysis
Invivo5 Anatomage
Featuring: LINEAR CORRECTIONS
DIAGNOSTIC Guide
SURGICAL Guide
Fabrication of DIAGNOSTIC guide
Line marked on teeth to position original axis for initial 3/32” drill mm & 3 mm guide post.
facial view
3 mm X 30 mm guide post in 3/32” hole
3 mm guide sleeve placed on the 3 mm guide postand cast lubricated with petroleum jelly
Initial layer of Triad® Gel added to the guide sleeve cleats and cured to stabilize the guide sleeve.
DIAGNOSTIC Guide
showing the 3 mm guide sleeve attached to the cured acrylic ready to be placed for cone beam X-ray.
Additional and final layer of Triad® Gel extended to lingual and incisal surfaces of adjacent teeth
PRE-OPERATIVE
Software Evaluation
Invivo5 Anatomage
axial plane
tangential plane · mesial-distal
cross sectional plane · buccal-lingual
3D volume
INITIAL EVALUATION of DIAGNOSTIC guide sleeve position
Invivo5Anatomage
Invivo5Anatomage
# 9
Axial Plane
The markings on the concentric circles are 5 mm apart allowing measurements to be calculated.
virtual implant
Yellow line passing through the axis of the implant creates the view seen in the cross sectional view (next slide).
Greater accuracy in implant placement is achieved when the line representing the bucco-lingual plane is set at 90° to the buccal surface of the arch.
Dragging the yellow line in the software will change the cross sectional view as the line rotates about the axis of the implant.
Invivo5Anatomage # 9
preferred implant placement
axial plane
tangential plane · mesio-distal
cross sectional plane · bucco-lingual
3D Volume
Images from software evaluated in 3 planes: axial, mesio-distal & bucco-lingual
Invivo5Anatomage
Invivo5Anatomage
# 9
cross sectional plane · bucco-lingual
LINEAR CORRECTION
Yellow line passing through the axis of the implant.
The virtual implant is moved parallel & facial 1.3 mm to the location of the DIAGNOSTIC guide sleeve.
# 9
virtual implant
actual guide sleeve
5 mm grid intervals to allow measurements to be calculated.
Invivo5Anatomage
cross sectional view.
Illustrating preferred implant placement position (bucco-lingual)
5 mm grid intervals to allow measurements to be calculated.
virtual implant
Illustrating the preferred implant placement in the tangential view
The center of the virtual implant is located 1 mm mesial to the center of the DIAGNOSTIC guide sleeve.
actual guide sleeve
Invivo5Anatomage
LINEAR CORRECTION Illustrating preferred implant placement position (mesio-distal)
# 9
tangential view
axial plane
tangential plane · mesio-distal
cross sectional plane · bucco-lingual
3D Volume
Images from software evaluated in 3 planes: axial, mesio-distal & bucco-lingual
Invivo5Anatomage
Invivo5Anatomage
preferred implant placement tangential plane · mesio-distal
Review of Pre-op Corrections
#9LINEAR CORRECTION
Cosine is applied to determine correction data. * see next 3 slide
1.5 mm offset guide post rotated 45º toward the mesial & facial.
Pythagorean TheoremCOSINE Calculations for Guide Right™ Guides
The cosine of 45°
is recommended for Guide Right corrections
BECAUSE
rotating the offset guide post half way
between 2 adjacent planes (90° apart) is 45°.
Correction based on the calculations
from the Pythagorean Theorem
To move the position of the guide sleeve 1 mm both mesially & buccally:
► use a 1.5 mm offset guide post
► and rotate the offset guide post 45º to a mesio-buccal position.
Cosine of 45° X 1.5 mm = 0.71 X 1.5 mm = 1.06 mm
facial 1.06 mm
A = 1
.5 m
m
45°
mes
ial
1.06
m
m
mesio-facial
A= cosine of 45º X 1.5(0.707 X 1.5 mm = 1.06 mm
45°
guide post center
A= cosine of 45º X 1.5(0.707 X 1.5 mm = 1.06 mm
mesial 1.06 mm
mesio-fa
cial
f
acia
l 1
.0
45°
Fabrication of SURGICAL guide
palatal view
1.5 mm offset guide post rotated 45º toward the mesial & facial.
Initial application of Triad® Gel to capture the cleats on the open guide sleeve to form the SURGICAL guide.
Additional Triad® Gel added to adjacent teeth
Final SURGICAL guide
SURGICAL guide (facial view)
POST-operative RESULTS
Software AnalysisInvivo5Anatomage
# 9 POST-OP RESULTS
axial plane
tangential plane · mesio-distal
cross sectional plane · bucco-lingual
3D Volume
showing actual implant placement.
Invivo5Anatomage
Axial Plane
The markings on the concentric circles are 5 mm apart allowing measurements to be calculated.
virtual implant
Yellow line passing through the axis of the implant creates the view seen in the cross sectional view (next slide).
Greater accuracy in implant placement is achieved when the line representing the bucco-lingual plane is set at 90° to the buccal surface of the arch.
Dragging the yellow line in the software will change the cross sectional view as the line rotates about the axis of the implant.
# 9 POST-OP results
Invivo5Anatomage
Cross Section (bucco-lingual)
virtual implantsuperimposed over actual implant
actual open guide sleeve
Yellow line passing through the axis of the implant.
5 mm grid intervals to allow measurements to be calculated.
# 9 POST-OP results
Only one wall of
open guide sleeve is visible.
Invivo5Anatomage
Tangential (mesio-distal)
5 mm grid intervals to allow measurements to be calculated.
virtual implant superimposed over actual implant.
actual guide sleeve
# 9 POST-OP result
Invivo5Anatomage
Guide Right™ Products shown in this case
1 - 3/32” drill
1 - 3 mm X 30 mm Guide Post
1- 3 mm Guide Sleeve
1 - 3 mm x 1.5 mm Offset Magnetic Guide Post
1 - 3 mm Open Guide Sleeve
Generation ll Bending Tool
Triad® Gel
1.800.314.0065 • www.deplaque.com
In-office or lab fabrication
Evaluate with 2D & 3D imaging
Allows linear and angular correction
Enables precision implant placement
Cost effective
A System of Components
for the fabrication and correction of diagnostic & surgical templates in one or two dimensions
1.800.314.0065 • www.deplaque.com
Guide Right™ Surgical Guide System
Start With Precision. Place With Confidence.™
1.800.314.0065 • www.deplaque.com
fabricate ▪ evaluate ▪ correct ▪ verify ▪ place
DéPlaque