80 3 acmaxx axial fans - dacpol · ac 6100 nm 350 206 115 / 230 50 / 60 85 ... 265 52 6,1 / 14 2...

10
184 2014-11 Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54 ACmaxx axial fans Series AC 8300 H 80 x 80 x 32 mm max. 80 m 3 /h Material: Housing: GRP 1) (PBTP) Impeller: GRP 1) (PA) Direction of air flow: Exhaust over struts Direction of rotation: Clockwise, seen on rotor Connection: Via single wires AWG 22, TR 64 Highlights: Universally usable for all mains voltages between 85 and 265 VAC Mass: 325 g 1) Fibreglass-reinforced plastic + 0,3 64 32 5 22 + 0,5 10 20 20 60 80 30 40 40 50 60 100 120 0 8 16 24 32 40 0,4 0,3 0,2 0,1 m³/h Pa CFM [in H 2 O] 1 Nominal voltage Air flow Air flow Frequency Voltage range Sintec sleeve bearings Ball bearings Input power Nominal speed Temperature range Service life L 10 at 40 °C at T max Curve Nominal data Type m 3 /h CFM VAC Hz VAC dB(A) Bel(A) / Watts rpm °C Hours Hours AC 8300 H 80 47 115 / 230 50 / 60 85 ... 265 48 6,2 / 8,3 5 000 -20...+75 55 000 / 25 000 Subject to alternations Speed variants available on request. Sound pressure level Sound power level tin-plated Guard grilles p. 240

Upload: others

Post on 10-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 80 3 ACmaxx axial fans - DACPOL · AC 6100 NM 350 206 115 / 230 50 / 60 85 ... 265 52 6,1 / 14 2 850 -20...+70 80 000 / 37 500 Subject to alternations – Possible special versions:

184

2014

-11

– Possible special versions:(See chapter DC fans - specials)

- Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54

ACmaxx axial fansSeries AC 8300 H 80 x 80 x 32 mm

max. 80 m3/h

– Material: Housing: GRP1) (PBTP) Impeller: GRP1) (PA)

– Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor– Connection: Via single wires AWG 22,

TR 64– Highlights: Universally usable for all

mains voltages between 85 and 265 VAC

– Mass: 325 g

1) Fibreglass-reinforced plastic

+ 0,3

64

32

5 22

+ 0,510 20

20

60

80

30 40

40

50 60

100

120

0 8 16 24 32 40

0,4

0,3

0,2

0,1

m³/h

Pa

CFM

[in H

2O]

1

Nom

inal

vol

tage

Air f

low

Air f

low

Freq

uenc

y

Volta

ge ra

nge

Sint

ec s

leev

e be

arin

gsBa

ll be

arin

gs

Inpu

t pow

er

Nom

inal

spe

ed

Tem

pera

ture

rang

e

Serv

ice

life

L 10

at 4

0 °C

at T

max

Curv

eNominal data

Type m3/h CFM VAC Hz VAC dB(A) Bel(A) / Watts rpm °C Hours Hours

AC 8300 H 80 47 115 / 230 50 / 60 85 ... 265 48 6,2 / 8,3 5 000 -20...+75 55 000 / 25 000 ➀Subject to alternations

Speed variants available on request.

Soun

d pr

essu

re le

vel

Soun

d po

wer

leve

l

tin-plated

Guard grillesp. 240

Page 2: 80 3 ACmaxx axial fans - DACPOL · AC 6100 NM 350 206 115 / 230 50 / 60 85 ... 265 52 6,1 / 14 2 850 -20...+70 80 000 / 37 500 Subject to alternations – Possible special versions:

Type m3/h CFM VAC Hz VAC dB(A) Bel(A) / Watts rpm °C Hours Hours

AC 3200 JH 144 85 115 / 230 50 / 60 85 ... 265 55 6,4 / 12 6 800 -20...+70 70 000 / 35 000 ➀Subject to alternations

185

2014

-11

– Possible special versions:(See chapter DC fans - specials)

- Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54

ACmaxx axial fansSeries AC 3200 J 92 x 92 x 38 mm

max. 144 m3/h

– Material: Housing: GRP1) (PBTP) Impeller: GRP1) (PA)

– Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor– Connection: Via single wires AWG 22,

TR 64– Highlights: Universally usable for all

mains voltages between 85 and 265 VAC

– Mass: 325 g

1) Fibreglass-reinforced plastic

20 40

40

80

60

160

200

80

120

100 120

0 15 30 45 60 75

0,7

0,6

0,5

0,4

0,3

0,2

0,1

m³/h

Pa

CFM

[in H

2O]

1

61.7+

0.2

54.2

+ 0

.15

38

70.7+ 0.80.3

+ 0.5

6+ 0.3 6+ 0.3

Nominal data

Speed variants available on request.

tin-plated

Guard grillesp. 240

Info

rmat

ion

DC a

xial

fans

DC fa

ns -

spe

cial

sAC

max

x / G

reen

Tech

EC

-Com

pact

fans

AC a

xial

fans

Acce

ssor

ies

Repr

esen

tativ

esDC

cen

trifu

gal f

ans

AC c

entr

ifuga

l fan

s

Nom

inal

vol

tage

Air f

low

Air f

low

Freq

uenc

y

Volta

ge ra

nge

Sint

ec s

leev

e be

arin

gsBa

ll be

arin

gs

Inpu

t pow

er

Nom

inal

spe

ed

Tem

pera

ture

rang

e

Serv

ice

life

L 10

at 4

0 °C

at T

max

Soun

d pr

essu

re le

vel

Soun

d po

wer

leve

l

Page 3: 80 3 ACmaxx axial fans - DACPOL · AC 6100 NM 350 206 115 / 230 50 / 60 85 ... 265 52 6,1 / 14 2 850 -20...+70 80 000 / 37 500 Subject to alternations – Possible special versions:

186

2014

-11

– Possible special versions:(See chapter DC fans - specials)

- Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture

ACmaxx axial fansSeries AC 4400 FN 119 x 119 x 25 mm

max. 205 m3/h

– Material: Housing: GRP1) (PBTP) Impeller: GRP1) (PA)

– Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen

on rotor– Connection: Via single wires AWG 22,

TR 64– Highlights: Universally usable for all

mains voltages between 85 and 265 VAC

– Mass: 370 g

1) Fibreglass-reinforced plastic

57.957.9

25.425.4

+ 0.5+ 0.5

+ 0.15+ 0.15

50 100

25

50

75

150

150

200

100

125

250

0 30 60 90 120 150

0,5

0,4

0,1

0,2

0,3

m³/h

Pa

CFM

[in H

2O]

1

Nominal data

Type m3/h CFM VAC Hz VAC dB(A) Bel(A) / Watts rpm °C Hours Hours

Speed variants available on request.

AC 4400 FNN 205 121 115 / 230 50 / 60 85 ... 265 53 6,2 / 12 4 850 -20...+70 60 000 / 30 000 ➀Subject to alternations

tin-plated

Guard grillesp. 240

Nom

inal

vol

tage

Air f

low

Air f

low

Freq

uenc

y

Volta

ge ra

nge

Sint

ec s

leev

e be

arin

gsBa

ll be

arin

gs

Inpu

t pow

er

Nom

inal

spe

ed

Tem

pera

ture

rang

e

Serv

ice

life

L 10

at 4

0 °C

at T

max

Soun

d pr

essu

re le

vel

Soun

d po

wer

leve

l

Page 4: 80 3 ACmaxx axial fans - DACPOL · AC 6100 NM 350 206 115 / 230 50 / 60 85 ... 265 52 6,1 / 14 2 850 -20...+70 80 000 / 37 500 Subject to alternations – Possible special versions:

Type m3/h CFM VAC Hz VAC dB(A) Bel(A) / Watts rpm °C Hours Hours

AC 4300 H 204 120 115 / 230 50 / 60 85 ... 265 51 6,4 / 12 3 400 -20...+70 45 000 / 22 500 ➀Subject to alternations

187

2014

-11

– Possible special versions:(See chapter DC fans - specials)

- Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54 / IP 68

ACmaxx axial fansSeries AC 4300 119 x 119 x 32 mm

max. 204 m3/h

– Material: Housing: GRP1) (PBTP) Impeller: GRP1) (PA)

– Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor– Connection: Via single wires AWG 22,

TR 64– Highlights: Universally usable for all

mains voltages between 85 and 265 VAC

– Mass: 325 g

1) Fibreglass-reinforced plastic

0 15 30 45 60 75 90

25 50

20

40

75 100 125

60

150

80

0,3

0,2

0,1

m³/h

Pa

CFM

[in H

2O]

1

Kenn

linie

Nominal data

Speed variants available on request.

tin-plated

Guard grillesp. 240

Info

rmat

ion

DC a

xial

fans

DC fa

ns -

spe

cial

sAC

max

x / G

reen

Tech

EC

-Com

pact

fans

AC a

xial

fans

Acce

ssor

ies

Repr

esen

tativ

esDC

cen

trifu

gal f

ans

AC c

entr

ifuga

l fan

s

Nom

inal

vol

tage

Air f

low

Air f

low

Freq

uenc

y

Volta

ge ra

nge

Sint

ec s

leev

e be

arin

gsBa

ll be

arin

gs

Inpu

t pow

er

Nom

inal

spe

ed

Tem

pera

ture

rang

e

Serv

ice

life

L 10

at 4

0 °C

at T

max

Soun

d pr

essu

re le

vel

Soun

d po

wer

leve

l

Page 5: 80 3 ACmaxx axial fans - DACPOL · AC 6100 NM 350 206 115 / 230 50 / 60 85 ... 265 52 6,1 / 14 2 850 -20...+70 80 000 / 37 500 Subject to alternations – Possible special versions:

– Possible special versions:(See chapter DC fans - specials)

- Protection against moisture - Protection against salt fog - Type of protection: IP 54

188

2014

-11

GreenTech EC-Compact fan axial fansSeries ACi 4400 119 x 119 x 38 mm

max. 175 m3/h

– Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA)

– Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor– Connection: via 2 flat plugs 2,8 x 0,5 mm

flying leads optional– Highlights: Fully integrated converter

and fan electronics– Mass: 250 g

1) Fibreglass-reinforced plastic

6 6

38+0,3 +0,3

+0,5

Nominal data

Type m3/h CFM VAC VAC dB(A) Bel(A) / Watts rpm °C Hours Hours

ACi 4420 ML 100 59 230 195...265 25 4,1 1,4 1 850 -20...+75 65 000 / 25 000 110 000 ➀

ACi 4420 N 147 86 230 195...265 36 4,9 2,8 2 700 -20...+75 65 000 / 25 000 110 000 ➁

ACi 4420 H 160 94 230 195...265 39 5,1 3,3 3 000 -20...+75 65 000 / 25 000 110 000 ➂

ACi 4420 HH 175 103 230 195...265 42 5,3 4,4 3 300 -20...+75 65 000 / 25 000 110 000 ➃

ACi 4410 HH 175 103 115 85...132 42 5,3 4,4 3 300 -20...+75 65 000 / 25 000 110 000 ➃Subject to alternations

Guard grillesp. 240

Connection cablesp. 251

Nom

inal

vol

tage

Air f

low

Air f

low

Volta

ge ra

nge

Soun

d pr

essu

re le

vel

Soun

d po

wer

leve

l

Sint

ec s

leev

e be

arin

gsBa

ll be

arin

gs

Inpu

t pow

er

Nom

inal

spe

ed

Tem

pera

ture

rang

e

Serv

ice

life

L 10

(40

°C)

ebm

-pap

st S

tand

ard

Serv

ice

life

L 10

(Tm

ax)

ebm

-pap

st S

tand

ard

Life

exp

ecta

ncy

L 10I

PC(4

0 °C

) se

e pa

ge 1

7

Curv

e

Page 6: 80 3 ACmaxx axial fans - DACPOL · AC 6100 NM 350 206 115 / 230 50 / 60 85 ... 265 52 6,1 / 14 2 850 -20...+70 80 000 / 37 500 Subject to alternations – Possible special versions:

189

2014

-11

Info

rmat

ion

DC a

xial

fans

DC fa

ns -

spe

cial

sAC

max

x / G

reen

Tech

EC

-Com

pact

fans

AC a

xial

fans

Acce

ssor

ies

Repr

esen

tativ

esDC

cen

trifu

gal f

ans

AC c

entr

ifuga

l fan

s

Page 7: 80 3 ACmaxx axial fans - DACPOL · AC 6100 NM 350 206 115 / 230 50 / 60 85 ... 265 52 6,1 / 14 2 850 -20...+70 80 000 / 37 500 Subject to alternations – Possible special versions:

190

2014

-11

– Material: Wall ring: Plastic PP, fibreglass-reinforced Blades: Plastic PA, fibreglass-reinforced – Number of blades: 7– Direction of air flow: "V", exhaust over struts– Direction of rotation: Counter-clockwise, seen on rotor– Type of protection: IP 54– Insulation class: "B"– Mounting position: Any– Condensate discharges: None– Operation mode: Continuous operation (S1)– Bearings: Maintenance-free ball bearings

Nominal data

Type

Subject to alternations (1) Nominal data in operating point with maximum load and 115 or 230 VAC

W1G130-AA49 -01 M1G 055-AI

VAC Hz rpm W A Pa °C kg

1~ 115 50/60 3200 24 0,38 90 -30..+60 0,75

W1G130-AA25 -01 M1G 055-AI 1~ 230 50/60 3200 24 0,19 90 -30..+70 0,75

Curv

e

Nom

inal

vol

tage

Freq

uenc

y

Spee

d / r

pm(1

)

Max

.inpu

t pow

er(1

)

Max

.cur

rent

dra

w(1

)

Max

. bac

k-pr

essu

re

Perm

. am

b. te

mp.

Mas

s

Motor

A

B

A

1

2

3

4

5

6

7

8

3200

3200

3200

3200

2800

2800

2800

2800

23

24

24

24

16

16

16

16

0,38

0,38

0,38

0,38

0,26

0,26

0,26

0,26

A

A

A

A

A

A

A

A

63

61

60

63

60

58

57

60

B

1

2

3

4

5

6

7

8

3200

3200

3200

3200

2800

2800

2800

2800

23

24

24

24

16

16

16

16

0,19

0,19

0,19

0,19

0,13

0,13

0,13

0,13

B

B

B

B

B

B

B

B

63

61

60

63

60

58

57

60

nrpm

PedW

IA

LWAdB(A)

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection againstaccidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acousticvalues given are only valid under the measurment conditions listed and may vary depending on the installation situation.With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!For detailed information see http://www.ebmpapst.com/general conditions

Curve:

Energy-saving axial fansØ 130 mm

Elec

trica

l con

nect

ions

p. 259 / J7)

p. 259 / J7)

max. 370 m3/h

Page 8: 80 3 ACmaxx axial fans - DACPOL · AC 6100 NM 350 206 115 / 230 50 / 60 85 ... 265 52 6,1 / 14 2 850 -20...+70 80 000 / 37 500 Subject to alternations – Possible special versions:

191

2014

-11

❮ "V"

Connection lead (total length 450 mm)is fitted ex works and can be detached.

– Motor protection: Via electronics and TOP– Electrical connection: Plug-in connection on motor side– Protection class: II– Product conforming

to standards: CE; EN 60335-1– Approvals: VDE, UL, CSA, GOST are applied for– Speed: Using the programming unit 2 speeds between nmin and nmax can be programmed

Guard grillesfrom p. 238

Electrical connectionsp. 259

Info

rmat

ion

DC a

xial

fans

DC fa

ns -

spe

cial

sAC

max

x / G

reen

Tech

EC

-Com

pact

fans

AC a

xial

fans

Acce

ssor

ies

Repr

esen

tativ

esDC

cen

trifu

gal f

ans

AC c

entr

ifuga

l fan

s

Page 9: 80 3 ACmaxx axial fans - DACPOL · AC 6100 NM 350 206 115 / 230 50 / 60 85 ... 265 52 6,1 / 14 2 850 -20...+70 80 000 / 37 500 Subject to alternations – Possible special versions:

192

2014

-11

Type m3/h CFM VAC Hz VAC dB(A) Bel(A) / Watts rpm °C Hours Hours

AC 6100 NM 350 206 115 / 230 50 / 60 85 ... 265 52 6,1 / 14 2 850 -20...+70 80 000 / 37 500 ➀Subject to alternations

– Possible special versions:(See chapter DC fans - specials)

- Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture

ACmaxx axial fansSeries AC 6100 N 172 x 160 x 51 mm

max. 350 m3/h

– Material: Housing: GRP1) (PA) Impeller: GRP1) (PA)

– Direction of air flow: Exhaust over struts – Direction of rotation: Counter clockwise, seen

on rotor– Connection: Via single wires AWG 22,

TR 64– Highlights: Universally usable for all

mains voltages between 85 and 265 VAC, 50-60 Hz

– Mass: 760 g

1) Fibreglass-reinforced plastic

100

25

50

75

200

100

125

150

300

0 40 80 120 160 200

0,5

0,4

0,3

0,2

0,1

m³/h

Pa

CFM

[in H

2O]

1

8,2 deep

Nominal data

Speed variants available on request.

tin-plated

Guard grillesp. 240

Nom

inal

vol

tage

Air f

low

Air f

low

Freq

uenc

y

Volta

ge ra

nge

Sint

ec s

leev

e be

arin

gsBa

ll be

arin

gs

Inpu

t pow

er

Nom

inal

spe

ed

Tem

pera

ture

rang

e

Serv

ice

life

L 10

at 4

0 °C

at T

max

Curv

e

Soun

d pr

essu

re le

vel

Soun

d po

wer

leve

l

Page 10: 80 3 ACmaxx axial fans - DACPOL · AC 6100 NM 350 206 115 / 230 50 / 60 85 ... 265 52 6,1 / 14 2 850 -20...+70 80 000 / 37 500 Subject to alternations – Possible special versions:

Nominal data

Type m3/h CFM VAC Hz VAC dB(A) Bel(A) / Watts rpm °C Hours Hours

AC 6200 NM 350 206 115 / 230 50 / 60 85 ... 265 50 5,7 / 14 2 850 -20...+70 80 000 / 40 000 ➀Subject to alternations

193

2014

-11

– Possible special versions:(See chapter DC fans - specials)

- Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54

ACmaxx axial fansSeries AC 6200 N Ø 172 x 51 mm

max. 350 m3/h

– Material: Housing: Die-cast aluminium Impeller: GRP1) (PA)

– Direction of air flow: Exhaust over struts – Direction of rotation: Counter clockwise, seen

on rotor– Connection: Via single wires AWG 22,

TR 64– Highlights: Universally usable for all

mains voltages between 85 and 265 VAC, 50-60 Hz Housing with grounding lug for screw M4 x 8 (Torx)

– Mass: 900 g1) Fibreglass-reinforced plastic

30,5

83,3

+0,2

+0,6

15

7,57,5

0,80,8

10

10

166

63,7

74

50 100 1500

100 200

25

50

100

300

75

0,4

0,3

0,2

0,1

m³/h

Pa

CFM

[in H

2O]

1

Speed variants available on request.

8,2 deep

tin-plated

Guard grillesp. 240

Info

rmat

ion

DC a

xial

fans

DC fa

ns -

spe

cial

sAC

max

x / G

reen

Tech

EC

-Com

pact

fans

AC a

xial

fans

Acce

ssor

ies

Repr

esen

tativ

esDC

cen

trifu

gal f

ans

AC c

entr

ifuga

l fan

s

Nom

inal

vol

tage

Air f

low

Air f

low

Freq

uenc

y

Volta

ge ra

nge

Sint

ec s

leev

e be

arin

gsBa

ll be

arin

gs

Inpu

t pow

er

Nom

inal

spe

ed

Tem

pera

ture

rang

e

Serv

ice

life

L 10

at 4

0 °C

at T

max

Curv

e

Soun

d pr

essu

re le

vel

Soun

d po

wer

leve

l