80 3 acmaxx axial fans - dacpol · ac 6100 nm 350 206 115 / 230 50 / 60 85 ... 265 52 6,1 / 14 2...
TRANSCRIPT
184
2014
-11
– Possible special versions:(See chapter DC fans - specials)
- Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54
ACmaxx axial fansSeries AC 8300 H 80 x 80 x 32 mm
max. 80 m3/h
– Material: Housing: GRP1) (PBTP) Impeller: GRP1) (PA)
– Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor– Connection: Via single wires AWG 22,
TR 64– Highlights: Universally usable for all
mains voltages between 85 and 265 VAC
– Mass: 325 g
1) Fibreglass-reinforced plastic
+ 0,3
64
32
5 22
+ 0,510 20
20
60
80
30 40
40
50 60
100
120
0 8 16 24 32 40
0,4
0,3
0,2
0,1
m³/h
Pa
CFM
[in H
2O]
1
Nom
inal
vol
tage
Air f
low
Air f
low
Freq
uenc
y
Volta
ge ra
nge
Sint
ec s
leev
e be
arin
gsBa
ll be
arin
gs
Inpu
t pow
er
Nom
inal
spe
ed
Tem
pera
ture
rang
e
Serv
ice
life
L 10
at 4
0 °C
at T
max
Curv
eNominal data
Type m3/h CFM VAC Hz VAC dB(A) Bel(A) / Watts rpm °C Hours Hours
AC 8300 H 80 47 115 / 230 50 / 60 85 ... 265 48 6,2 / 8,3 5 000 -20...+75 55 000 / 25 000 ➀Subject to alternations
Speed variants available on request.
Soun
d pr
essu
re le
vel
Soun
d po
wer
leve
l
tin-plated
Guard grillesp. 240
Type m3/h CFM VAC Hz VAC dB(A) Bel(A) / Watts rpm °C Hours Hours
AC 3200 JH 144 85 115 / 230 50 / 60 85 ... 265 55 6,4 / 12 6 800 -20...+70 70 000 / 35 000 ➀Subject to alternations
185
2014
-11
– Possible special versions:(See chapter DC fans - specials)
- Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54
ACmaxx axial fansSeries AC 3200 J 92 x 92 x 38 mm
max. 144 m3/h
– Material: Housing: GRP1) (PBTP) Impeller: GRP1) (PA)
– Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor– Connection: Via single wires AWG 22,
TR 64– Highlights: Universally usable for all
mains voltages between 85 and 265 VAC
– Mass: 325 g
1) Fibreglass-reinforced plastic
20 40
40
80
60
160
200
80
120
100 120
0 15 30 45 60 75
0,7
0,6
0,5
0,4
0,3
0,2
0,1
m³/h
Pa
CFM
[in H
2O]
1
61.7+
0.2
54.2
+ 0
.15
38
70.7+ 0.80.3
+ 0.5
6+ 0.3 6+ 0.3
Nominal data
Speed variants available on request.
tin-plated
Guard grillesp. 240
Info
rmat
ion
DC a
xial
fans
DC fa
ns -
spe
cial
sAC
max
x / G
reen
Tech
EC
-Com
pact
fans
AC a
xial
fans
Acce
ssor
ies
Repr
esen
tativ
esDC
cen
trifu
gal f
ans
AC c
entr
ifuga
l fan
s
Nom
inal
vol
tage
Air f
low
Air f
low
Freq
uenc
y
Volta
ge ra
nge
Sint
ec s
leev
e be
arin
gsBa
ll be
arin
gs
Inpu
t pow
er
Nom
inal
spe
ed
Tem
pera
ture
rang
e
Serv
ice
life
L 10
at 4
0 °C
at T
max
Soun
d pr
essu
re le
vel
Soun
d po
wer
leve
l
186
2014
-11
– Possible special versions:(See chapter DC fans - specials)
- Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture
ACmaxx axial fansSeries AC 4400 FN 119 x 119 x 25 mm
max. 205 m3/h
– Material: Housing: GRP1) (PBTP) Impeller: GRP1) (PA)
– Direction of air flow: Exhaust over struts – Direction of rotation: Counter-clockwise, seen
on rotor– Connection: Via single wires AWG 22,
TR 64– Highlights: Universally usable for all
mains voltages between 85 and 265 VAC
– Mass: 370 g
1) Fibreglass-reinforced plastic
57.957.9
25.425.4
+ 0.5+ 0.5
+ 0.15+ 0.15
50 100
25
50
75
150
150
200
100
125
250
0 30 60 90 120 150
0,5
0,4
0,1
0,2
0,3
m³/h
Pa
CFM
[in H
2O]
1
Nominal data
Type m3/h CFM VAC Hz VAC dB(A) Bel(A) / Watts rpm °C Hours Hours
Speed variants available on request.
AC 4400 FNN 205 121 115 / 230 50 / 60 85 ... 265 53 6,2 / 12 4 850 -20...+70 60 000 / 30 000 ➀Subject to alternations
tin-plated
Guard grillesp. 240
Nom
inal
vol
tage
Air f
low
Air f
low
Freq
uenc
y
Volta
ge ra
nge
Sint
ec s
leev
e be
arin
gsBa
ll be
arin
gs
Inpu
t pow
er
Nom
inal
spe
ed
Tem
pera
ture
rang
e
Serv
ice
life
L 10
at 4
0 °C
at T
max
Soun
d pr
essu
re le
vel
Soun
d po
wer
leve
l
Type m3/h CFM VAC Hz VAC dB(A) Bel(A) / Watts rpm °C Hours Hours
AC 4300 H 204 120 115 / 230 50 / 60 85 ... 265 51 6,4 / 12 3 400 -20...+70 45 000 / 22 500 ➀Subject to alternations
187
2014
-11
– Possible special versions:(See chapter DC fans - specials)
- Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54 / IP 68
ACmaxx axial fansSeries AC 4300 119 x 119 x 32 mm
max. 204 m3/h
– Material: Housing: GRP1) (PBTP) Impeller: GRP1) (PA)
– Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor– Connection: Via single wires AWG 22,
TR 64– Highlights: Universally usable for all
mains voltages between 85 and 265 VAC
– Mass: 325 g
1) Fibreglass-reinforced plastic
0 15 30 45 60 75 90
25 50
20
40
75 100 125
60
150
80
0,3
0,2
0,1
m³/h
Pa
CFM
[in H
2O]
1
Kenn
linie
Nominal data
Speed variants available on request.
tin-plated
Guard grillesp. 240
Info
rmat
ion
DC a
xial
fans
DC fa
ns -
spe
cial
sAC
max
x / G
reen
Tech
EC
-Com
pact
fans
AC a
xial
fans
Acce
ssor
ies
Repr
esen
tativ
esDC
cen
trifu
gal f
ans
AC c
entr
ifuga
l fan
s
Nom
inal
vol
tage
Air f
low
Air f
low
Freq
uenc
y
Volta
ge ra
nge
Sint
ec s
leev
e be
arin
gsBa
ll be
arin
gs
Inpu
t pow
er
Nom
inal
spe
ed
Tem
pera
ture
rang
e
Serv
ice
life
L 10
at 4
0 °C
at T
max
Soun
d pr
essu
re le
vel
Soun
d po
wer
leve
l
– Possible special versions:(See chapter DC fans - specials)
- Protection against moisture - Protection against salt fog - Type of protection: IP 54
188
2014
-11
GreenTech EC-Compact fan axial fansSeries ACi 4400 119 x 119 x 38 mm
max. 175 m3/h
– Material: Housing: GRP1) (PBT) Impeller: GRP1) (PA)
– Direction of air flow: Exhaust over struts – Direction of rotation: Clockwise, seen on rotor– Connection: via 2 flat plugs 2,8 x 0,5 mm
flying leads optional– Highlights: Fully integrated converter
and fan electronics– Mass: 250 g
1) Fibreglass-reinforced plastic
6 6
38+0,3 +0,3
+0,5
Nominal data
Type m3/h CFM VAC VAC dB(A) Bel(A) / Watts rpm °C Hours Hours
ACi 4420 ML 100 59 230 195...265 25 4,1 1,4 1 850 -20...+75 65 000 / 25 000 110 000 ➀
ACi 4420 N 147 86 230 195...265 36 4,9 2,8 2 700 -20...+75 65 000 / 25 000 110 000 ➁
ACi 4420 H 160 94 230 195...265 39 5,1 3,3 3 000 -20...+75 65 000 / 25 000 110 000 ➂
ACi 4420 HH 175 103 230 195...265 42 5,3 4,4 3 300 -20...+75 65 000 / 25 000 110 000 ➃
ACi 4410 HH 175 103 115 85...132 42 5,3 4,4 3 300 -20...+75 65 000 / 25 000 110 000 ➃Subject to alternations
Guard grillesp. 240
Connection cablesp. 251
Nom
inal
vol
tage
Air f
low
Air f
low
Volta
ge ra
nge
Soun
d pr
essu
re le
vel
Soun
d po
wer
leve
l
Sint
ec s
leev
e be
arin
gsBa
ll be
arin
gs
Inpu
t pow
er
Nom
inal
spe
ed
Tem
pera
ture
rang
e
Serv
ice
life
L 10
(40
°C)
ebm
-pap
st S
tand
ard
Serv
ice
life
L 10
(Tm
ax)
ebm
-pap
st S
tand
ard
Life
exp
ecta
ncy
L 10I
PC(4
0 °C
) se
e pa
ge 1
7
Curv
e
189
2014
-11
Info
rmat
ion
DC a
xial
fans
DC fa
ns -
spe
cial
sAC
max
x / G
reen
Tech
EC
-Com
pact
fans
AC a
xial
fans
Acce
ssor
ies
Repr
esen
tativ
esDC
cen
trifu
gal f
ans
AC c
entr
ifuga
l fan
s
190
2014
-11
– Material: Wall ring: Plastic PP, fibreglass-reinforced Blades: Plastic PA, fibreglass-reinforced – Number of blades: 7– Direction of air flow: "V", exhaust over struts– Direction of rotation: Counter-clockwise, seen on rotor– Type of protection: IP 54– Insulation class: "B"– Mounting position: Any– Condensate discharges: None– Operation mode: Continuous operation (S1)– Bearings: Maintenance-free ball bearings
Nominal data
Type
Subject to alternations (1) Nominal data in operating point with maximum load and 115 or 230 VAC
W1G130-AA49 -01 M1G 055-AI
VAC Hz rpm W A Pa °C kg
1~ 115 50/60 3200 24 0,38 90 -30..+60 0,75
W1G130-AA25 -01 M1G 055-AI 1~ 230 50/60 3200 24 0,19 90 -30..+70 0,75
Curv
e
Nom
inal
vol
tage
Freq
uenc
y
Spee
d / r
pm(1
)
Max
.inpu
t pow
er(1
)
Max
.cur
rent
dra
w(1
)
Max
. bac
k-pr
essu
re
Perm
. am
b. te
mp.
Mas
s
Motor
A
B
A
1
2
3
4
5
6
7
8
3200
3200
3200
3200
2800
2800
2800
2800
23
24
24
24
16
16
16
16
0,38
0,38
0,38
0,38
0,26
0,26
0,26
0,26
A
A
A
A
A
A
A
A
63
61
60
63
60
58
57
60
B
1
2
3
4
5
6
7
8
3200
3200
3200
3200
2800
2800
2800
2800
23
24
24
24
16
16
16
16
0,19
0,19
0,19
0,19
0,13
0,13
0,13
0,13
B
B
B
B
B
B
B
B
63
61
60
63
60
58
57
60
nrpm
PedW
IA
LWAdB(A)
Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection againstaccidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acousticvalues given are only valid under the measurment conditions listed and may vary depending on the installation situation.With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!For detailed information see http://www.ebmpapst.com/general conditions
Curve:
Energy-saving axial fansØ 130 mm
Elec
trica
l con
nect
ions
p. 259 / J7)
p. 259 / J7)
max. 370 m3/h
191
2014
-11
❮ "V"
Connection lead (total length 450 mm)is fitted ex works and can be detached.
– Motor protection: Via electronics and TOP– Electrical connection: Plug-in connection on motor side– Protection class: II– Product conforming
to standards: CE; EN 60335-1– Approvals: VDE, UL, CSA, GOST are applied for– Speed: Using the programming unit 2 speeds between nmin and nmax can be programmed
Guard grillesfrom p. 238
Electrical connectionsp. 259
Info
rmat
ion
DC a
xial
fans
DC fa
ns -
spe
cial
sAC
max
x / G
reen
Tech
EC
-Com
pact
fans
AC a
xial
fans
Acce
ssor
ies
Repr
esen
tativ
esDC
cen
trifu
gal f
ans
AC c
entr
ifuga
l fan
s
192
2014
-11
Type m3/h CFM VAC Hz VAC dB(A) Bel(A) / Watts rpm °C Hours Hours
AC 6100 NM 350 206 115 / 230 50 / 60 85 ... 265 52 6,1 / 14 2 850 -20...+70 80 000 / 37 500 ➀Subject to alternations
– Possible special versions:(See chapter DC fans - specials)
- Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture
ACmaxx axial fansSeries AC 6100 N 172 x 160 x 51 mm
max. 350 m3/h
– Material: Housing: GRP1) (PA) Impeller: GRP1) (PA)
– Direction of air flow: Exhaust over struts – Direction of rotation: Counter clockwise, seen
on rotor– Connection: Via single wires AWG 22,
TR 64– Highlights: Universally usable for all
mains voltages between 85 and 265 VAC, 50-60 Hz
– Mass: 760 g
1) Fibreglass-reinforced plastic
100
25
50
75
200
100
125
150
300
0 40 80 120 160 200
0,5
0,4
0,3
0,2
0,1
m³/h
Pa
CFM
[in H
2O]
1
8,2 deep
Nominal data
Speed variants available on request.
tin-plated
Guard grillesp. 240
Nom
inal
vol
tage
Air f
low
Air f
low
Freq
uenc
y
Volta
ge ra
nge
Sint
ec s
leev
e be
arin
gsBa
ll be
arin
gs
Inpu
t pow
er
Nom
inal
spe
ed
Tem
pera
ture
rang
e
Serv
ice
life
L 10
at 4
0 °C
at T
max
Curv
e
Soun
d pr
essu
re le
vel
Soun
d po
wer
leve
l
Nominal data
Type m3/h CFM VAC Hz VAC dB(A) Bel(A) / Watts rpm °C Hours Hours
AC 6200 NM 350 206 115 / 230 50 / 60 85 ... 265 50 5,7 / 14 2 850 -20...+70 80 000 / 40 000 ➀Subject to alternations
193
2014
-11
– Possible special versions:(See chapter DC fans - specials)
- Speed signal - Go / No-go alarm - Alarm with limit speed - External temperature sensor - Internal temperature sensor - PWM control input - Analogue control input - Protection against moisture - Protection against salt fog - Type of protection: IP 54
ACmaxx axial fansSeries AC 6200 N Ø 172 x 51 mm
max. 350 m3/h
– Material: Housing: Die-cast aluminium Impeller: GRP1) (PA)
– Direction of air flow: Exhaust over struts – Direction of rotation: Counter clockwise, seen
on rotor– Connection: Via single wires AWG 22,
TR 64– Highlights: Universally usable for all
mains voltages between 85 and 265 VAC, 50-60 Hz Housing with grounding lug for screw M4 x 8 (Torx)
– Mass: 900 g1) Fibreglass-reinforced plastic
30,5
83,3
+0,2
+0,6
15
7,57,5
0,80,8
10
10
166
63,7
74
50 100 1500
100 200
25
50
100
300
75
0,4
0,3
0,2
0,1
m³/h
Pa
CFM
[in H
2O]
1
Speed variants available on request.
8,2 deep
tin-plated
Guard grillesp. 240
Info
rmat
ion
DC a
xial
fans
DC fa
ns -
spe
cial
sAC
max
x / G
reen
Tech
EC
-Com
pact
fans
AC a
xial
fans
Acce
ssor
ies
Repr
esen
tativ
esDC
cen
trifu
gal f
ans
AC c
entr
ifuga
l fan
s
Nom
inal
vol
tage
Air f
low
Air f
low
Freq
uenc
y
Volta
ge ra
nge
Sint
ec s
leev
e be
arin
gsBa
ll be
arin
gs
Inpu
t pow
er
Nom
inal
spe
ed
Tem
pera
ture
rang
e
Serv
ice
life
L 10
at 4
0 °C
at T
max
Curv
e
Soun
d pr
essu
re le
vel
Soun
d po
wer
leve
l