90-005-0017_x02 - mbp_acdc power supply manual
TRANSCRIPT
![Page 1: 90-005-0017_X02 - MBP_ACDC Power Supply Manual](https://reader030.vdocument.in/reader030/viewer/2022021316/577cc3441a28aba71195767c/html5/thumbnails/1.jpg)
8/10/2019 90-005-0017_X02 - MBP_ACDC Power Supply Manual
http://slidepdf.com/reader/full/90-005-0017x02-mbpacdc-power-supply-manual 1/16
Document
No:
90-005-0017 Rev: X02
545 West Terrace Drive
San Dimas, CA 91773
Author: EH,GE Date: 4/7/08
Description: MatchBox AC-DC Supply
Part Number: MBP-000300-XXXX Family
For use with Wavestream’s Ku-band (16W-40W) and Ka-band
Matchbox Amplifiers
![Page 2: 90-005-0017_X02 - MBP_ACDC Power Supply Manual](https://reader030.vdocument.in/reader030/viewer/2022021316/577cc3441a28aba71195767c/html5/thumbnails/2.jpg)
8/10/2019 90-005-0017_X02 - MBP_ACDC Power Supply Manual
http://slidepdf.com/reader/full/90-005-0017x02-mbpacdc-power-supply-manual 2/16
Matchbox AC-DC Supply
Doc. 90-005-0017 Rev. X02 Page 2 of 16
SPECIFICATIONS
PRIME
Prime Power 90-264 VAC, 50-60Hz
Efficiency Better than 90%
INTERFACE
AC Input Connector C016 20D003 110 12
Monitor and Control Input
Connector
MS3126F14-19S
DC and Monitor and Control
Output Connector
MS3126F18-32P
ENVIRONMENTAL
Operating Temperature -40oC to +60
oC ambient air temperature
Water Ingress IP-54
MECHANICAL
Size 5.4” W x 3.5” H x 9.1” L (138 mm W x 89 mm H x 231 mm L)
Weight 6.1 lbs (2.8 Kg)
![Page 3: 90-005-0017_X02 - MBP_ACDC Power Supply Manual](https://reader030.vdocument.in/reader030/viewer/2022021316/577cc3441a28aba71195767c/html5/thumbnails/3.jpg)
8/10/2019 90-005-0017_X02 - MBP_ACDC Power Supply Manual
http://slidepdf.com/reader/full/90-005-0017x02-mbpacdc-power-supply-manual 3/16
Matchbox AC-DC Supply
Doc. 90-005-0017 Rev. X02 Page 3 of 16
INTERFACES
AC Prime Power Requirements:
Voltage 115VAC, single phase
Current 15A circuit or greater
Other Do not run on a Ground Fault Interrupt protected circuit.
Note: It is advisable to run unit off a circuit with no ground faultinterrupt (GFI). The unit is high power and has a number of decoupling
capacitors for noise that connect to ground. There may be enough
current on the ground to trip a sensitive GFI circuit.
Electrical Interfaces:
Interface
Label
Description Connects to
J1 Output DC Power and Monitor and Control
32 Contacts, Sockets
(see Interface Specifications for mating connector)
MatchBox
J2 Monitor and Control
19 Contacts, Pins
(see Interface Specifications for mating connector)
Customer M/C
J3 AC Prime Power
4 Contacts, Pins
(see Interface Specifications for mating connector)
AC Prime
Power
![Page 4: 90-005-0017_X02 - MBP_ACDC Power Supply Manual](https://reader030.vdocument.in/reader030/viewer/2022021316/577cc3441a28aba71195767c/html5/thumbnails/4.jpg)
8/10/2019 90-005-0017_X02 - MBP_ACDC Power Supply Manual
http://slidepdf.com/reader/full/90-005-0017x02-mbpacdc-power-supply-manual 4/16
Matchbox AC-DC Supply
Doc. 90-005-0017 Rev. X02 Page 4 of 16
Mechanical Interfaces:
There are four mechanical mounting points, two each on two sides. Each takes a 1/4-20 screw
which will not protrude further than 0.30” into the unit. The mounting points are depicted here
on the mechanical drawing as the features described with the “2X 1/4-20 UNC .30” callout.
Full mechanical drawings can be found in the Outline and Mounting Drawings section.
Note: Do not use screws that are too long. When installing mounting hardware, if it feels
like the screw is bottoming out, check the screw length to be sure the screw is not too long.
Operating Instructions
Unpacking
Keep the shipping box and all packing materials for future use including return of the Unit for
repair.
Check the Unit for any visible damage. If the Unit is damaged, call Wavestream for an RMAnumber.
Inspect Interfaces
Inspect connectors and connector pins and remove any foreign objects such as packing material.
Perform Continuity Check on the Cables
![Page 5: 90-005-0017_X02 - MBP_ACDC Power Supply Manual](https://reader030.vdocument.in/reader030/viewer/2022021316/577cc3441a28aba71195767c/html5/thumbnails/5.jpg)
8/10/2019 90-005-0017_X02 - MBP_ACDC Power Supply Manual
http://slidepdf.com/reader/full/90-005-0017x02-mbpacdc-power-supply-manual 5/16
Matchbox AC-DC Supply
Doc. 90-005-0017 Rev. X02 Page 5 of 16
Even if the cables have been made in advance, it is important to use and ohm meter to perform a
continuity check on each of the individual wires. Incorrect wiring could permanently damage theUnit.
Pin-out tables are included at the end of this manual.
Installation and Connections
Proceed with installation according to standard practice.
See section on Mounting for mounting point specifications. Make sure that any screws used tomount the unit are the correct length.
Connect the Output DC Power and Monitor and Control (J1) connector to the MatchBox Input
DC Power and Monitor and Control.
Connect the Monitor and Control (J2) connector. Note: the monitor and control signals are
simply passed through the AC/DC Power Supply Unit from the MatchBox. For details on theM/C signals, see MatchBox Manual.
Connect the AC Prime Input (J3) connector to Prime AC Power source.
Note: Do not connect power to the Unit until the MatchBox is installed on the feed
and antenna. The MatchBox emits high power RF energy which could be harmful to the
human body.
Voltage 115VAC, single phase
Current 15A circuit or greater
Other Do not run on a Ground Fault Interrupt protected circuit.
Note: It is advisable to run unit off a circuit with no ground fault
interrupt (GFI). The unit is high power and has a number of decoupling
capacitors for noise that connect to ground. There may be enoughcurrent on the ground to trip a sensitive GFI circuit.
![Page 6: 90-005-0017_X02 - MBP_ACDC Power Supply Manual](https://reader030.vdocument.in/reader030/viewer/2022021316/577cc3441a28aba71195767c/html5/thumbnails/6.jpg)
8/10/2019 90-005-0017_X02 - MBP_ACDC Power Supply Manual
http://slidepdf.com/reader/full/90-005-0017x02-mbpacdc-power-supply-manual 6/16
Matchbox AC-DC Supply
Doc. 90-005-0017 Rev. X02 Page 6 of 16
Transmit Enable Configuration
Note: the monitor and control signals are simply passed through the AC/DC Power Supply Unit
from the MatchBox. For details on the M/C signals, see MatchBox Manual.
Hard-wired Enable:
If it is desired that the unit enables RF operation as soon as power is applied without
having to send a command, the unit should have a hard-wire TX Enable wire installed. To do this,
connect pin A (Secondary GND) to pin B (/TX_EN) on J2.
Once TX Enable is hardwired to be enabled, there is no way to disable the unit usingcommands. The unit must be powered down to disable it.
Discrete Enable:
If it is desired that the unit enables RF operation using the discrete enable signal without
having to send a command, the unit should be wired to an open collector on the customer side.To do this, connect pin A (Secondary GND) and pin B (/TX_EN) on J2 to the customer open
collector circuit.
Once TX Enable is enabled using the discrete signal, there is no way to disable the unit
using commands. The open collector circuit can be switched so that /TX_EN is not grounded, orthe unit may be powered down to disable it.
RS-485 Serial Command Enable:
If it is desired that the unit enables RF operation using a serial command enable signal,the unit should be have the serial wires connected as follows:
Pin Unit Signal
Name
Customer Side
Connection
F RX- TX-
G RS-485 GND Ground
H TX- RX-
S RX+ TX+
T TX+ RX+
If the unit is powered down, the unit will automatically come up disabled and a serial
command must be sent to enable the unit. For more information about the M/C serial operation
of the unit, see the MatchBox Manual.
![Page 7: 90-005-0017_X02 - MBP_ACDC Power Supply Manual](https://reader030.vdocument.in/reader030/viewer/2022021316/577cc3441a28aba71195767c/html5/thumbnails/7.jpg)
8/10/2019 90-005-0017_X02 - MBP_ACDC Power Supply Manual
http://slidepdf.com/reader/full/90-005-0017x02-mbpacdc-power-supply-manual 7/16
Matchbox AC-DC Supply
Doc. 90-005-0017 Rev. X02 Page 7 of 16
Cable Identification
If you are using cables from Wavestream to connect to the unit, the part numbers provided
correspond to the Wavestream cables.
J1 – AC/DC Output connector. Connect this to the Matchbox.
Attach Cable between J1 on the AC/DC Power Supply and the Power and M/C Connector onthe MatchBox.
Wavestream PN: 02-009-0091: 4ft cable
Wavestream PN: 02-009-0092: 8ft cable
![Page 8: 90-005-0017_X02 - MBP_ACDC Power Supply Manual](https://reader030.vdocument.in/reader030/viewer/2022021316/577cc3441a28aba71195767c/html5/thumbnails/8.jpg)
8/10/2019 90-005-0017_X02 - MBP_ACDC Power Supply Manual
http://slidepdf.com/reader/full/90-005-0017x02-mbpacdc-power-supply-manual 8/16
Matchbox AC-DC Supply
Doc. 90-005-0017 Rev. X02 Page 8 of 16
J2 – AC/DC Monitor and Control connector.
Attach Cable between J2 on the AC/DC Power Supply and customer RS-485 serial
connector.
Wavestream PN: 02-009-0093: D-sub cable
CustomerRS-485
Serial
DB-9
Connector
![Page 9: 90-005-0017_X02 - MBP_ACDC Power Supply Manual](https://reader030.vdocument.in/reader030/viewer/2022021316/577cc3441a28aba71195767c/html5/thumbnails/9.jpg)
8/10/2019 90-005-0017_X02 - MBP_ACDC Power Supply Manual
http://slidepdf.com/reader/full/90-005-0017x02-mbpacdc-power-supply-manual 9/16
Matchbox AC-DC Supply
Doc. 90-005-0017 Rev. X02 Page 9 of 16
J3 – AC/DC Prime AC Power connector.
Attach Cable between J3 on the AC/DC Power Supply and customer AC Prime Power
connection.
Note: It is advisable to run unit off a circuit with no ground fault interrupt(GFI). The unit is high power and has a number of decoupling capacitors for
noise that connect to ground. There may be enough current on the ground to
trip a sensitive GFI circuit.
Wavestream PN: 02-009-0094: AC cable
Customer115VAC
Single Phase
Prime
Power
Connection
![Page 10: 90-005-0017_X02 - MBP_ACDC Power Supply Manual](https://reader030.vdocument.in/reader030/viewer/2022021316/577cc3441a28aba71195767c/html5/thumbnails/10.jpg)
8/10/2019 90-005-0017_X02 - MBP_ACDC Power Supply Manual
http://slidepdf.com/reader/full/90-005-0017x02-mbpacdc-power-supply-manual 10/16
![Page 11: 90-005-0017_X02 - MBP_ACDC Power Supply Manual](https://reader030.vdocument.in/reader030/viewer/2022021316/577cc3441a28aba71195767c/html5/thumbnails/11.jpg)
8/10/2019 90-005-0017_X02 - MBP_ACDC Power Supply Manual
http://slidepdf.com/reader/full/90-005-0017x02-mbpacdc-power-supply-manual 11/16
Matchbox AC-DC Supply
Doc. 90-005-0017 Rev. X02 Page 11 of 16
Front View
![Page 12: 90-005-0017_X02 - MBP_ACDC Power Supply Manual](https://reader030.vdocument.in/reader030/viewer/2022021316/577cc3441a28aba71195767c/html5/thumbnails/12.jpg)
8/10/2019 90-005-0017_X02 - MBP_ACDC Power Supply Manual
http://slidepdf.com/reader/full/90-005-0017x02-mbpacdc-power-supply-manual 12/16
Matchbox AC-DC Supply
Doc. 90-005-0017 Rev. X02 Page 12 of 16
J1 – M&C and DC Output
Mating Connector: MS3126F18-32P
J1 – M&C and DC Output PinoutPin Signal Signal Type Reference
A Prime Power Prime_Rtn
B Prime Power Prime_Rtn
C Prime Power Prime_Rtn
D Prime_Rtn Power Rtn
E TX+ Ethernet Com Secondary GND
F TX- Ethernet Com Secondary GND
G RX+ Ethernet Com Secondary GND
H RX- Ethernet Com Secondary GND
J RS-485 GND RS-485 GND (use with RS-485) Digital GND, Secondary
Side
K RX- RS-485 Com Secondary GND
L RX+ RS-485 Com Secondary GND
M TX- RS-485 Com Secondary GND
N TX+ RS-485 Com Secondary GND
P Prime_Rtn Power Rtn
R Prime Power Prime_Rtn
S Prime Power Prime_Rtn
T Prime Power Prime_Rtn
U Prime_Good_Ref Prime_Good Reference Filtered Prime_Rtn
V Prime_Rtn Power Rtn
W Prime_Rtn Power Rtn
X TX_Active Monitor – TTL Secondary GND
Y HPA_Off Monitor – TTL Secondary GND
Z Over_Temp Monitor – TTL Secondary GND
a Analog_Temp Monitor – Analog (0 to +5V) Secondary GND
b Lock_Loss Monitor – TTL Secondary GND
c Sum_Fault Monitor - TTL Secondary GND
d Prime_Rtn Power Rtn
e Prime_Rtn Power Rtnf Prime_Good Monitor–Analog/TTL (0 to
+5.6V)
Prime_Good_Ref
g /TX_EN Control Secondary GND
h GND Secondary GND
j /LED_Off Control Secondary GND
![Page 13: 90-005-0017_X02 - MBP_ACDC Power Supply Manual](https://reader030.vdocument.in/reader030/viewer/2022021316/577cc3441a28aba71195767c/html5/thumbnails/13.jpg)
8/10/2019 90-005-0017_X02 - MBP_ACDC Power Supply Manual
http://slidepdf.com/reader/full/90-005-0017x02-mbpacdc-power-supply-manual 13/16
Matchbox AC-DC Supply
Doc. 90-005-0017 Rev. X02 Page 13 of 16
J1 – M&C and DC Output Layout
o
o
o
o
o
A
B
C
D
E
F
G
HJ
K
L
M
N
P
R
S
T
U
V
W
X
Y
Za
b
c
d
e
f
g
h
Prime
Secondary
Prime
Prime RTN
Secondary GND
Control Sig
Reference to SGND
o
Serial RS-485
Ethernet
o
Monitor Sig
reference to SGND
o Prime_Good
MaleLooking at the front of the pins
o Prime_Good Ref
o Serial RS-485 DGND
![Page 14: 90-005-0017_X02 - MBP_ACDC Power Supply Manual](https://reader030.vdocument.in/reader030/viewer/2022021316/577cc3441a28aba71195767c/html5/thumbnails/14.jpg)
8/10/2019 90-005-0017_X02 - MBP_ACDC Power Supply Manual
http://slidepdf.com/reader/full/90-005-0017x02-mbpacdc-power-supply-manual 14/16
Matchbox AC-DC Supply
Doc. 90-005-0017 Rev. X02 Page 14 of 16
J2 - M&C Input
Mating Connector: MS3126F14-19S
J2 – M&C Input PinoutPin Signal Signal Type Reference
A GND Secondary GND (SGND)B /TX_EN Control Pin A
Secondary GND
C RX- Ethernet Com Secondary GND
D Lock_Loss Monitor – TTL Pin A
Secondary GND
E Prime_Good_Ref Prime_Good Reference
Filtered MatchBox Prime RTN
F RX- RS-485 Com Pin G
RS-485 DGND
G RS-485 DGND RS-485 Digital GND Secondary Side
(ground to be used with RS-485)H TX- RS-485 Com Pin G
RS-485 DGND
J Prime_Good Monitor – TTL/Analog
(0 to +5.6V)
Pin E
Prime_Good_Ref
K Sum_Fault Monitor - TTL Pin A
Secondary GND
L TX- Ethernet Com Secondary GND
M /LED_Off Control Pin A
Secondary GND
N TX+ Ethernet Com Secondary GND
P RX+ Ethernet Com Secondary GND
R HPA_Off Monitor – TTL Pin ASecondary GND
S RX+ RS-485 Com Pin GRS-485 DGND
T TX+ RS-485 Com Pin GRS-485 DGND
U TX_Active Monitor – TTL Pin A
Secondary GND
V Over_Temp Monitor – TTL Pin A
Secondary GND
![Page 15: 90-005-0017_X02 - MBP_ACDC Power Supply Manual](https://reader030.vdocument.in/reader030/viewer/2022021316/577cc3441a28aba71195767c/html5/thumbnails/15.jpg)
8/10/2019 90-005-0017_X02 - MBP_ACDC Power Supply Manual
http://slidepdf.com/reader/full/90-005-0017x02-mbpacdc-power-supply-manual 15/16
Matchbox AC-DC Supply
Doc. 90-005-0017 Rev. X02 Page 15 of 16
J2 – M&C Input Pin Layout
Q
Prime Good
Secondary GND (SGND)
Serial RS-485 DGNDControl Signal
reference to SGND
Serial RS-485reference to DGND
EthernetMonitor Signal
reference to SGND
MaleViewed from
the front face
Prime Good Reference
Secondary Side Signals Com Signals
Prime Side Signals(MatchBox DC Prime, not AC Prime)
CPNL
FH
STJ E
A
DRVUK
B
G
![Page 16: 90-005-0017_X02 - MBP_ACDC Power Supply Manual](https://reader030.vdocument.in/reader030/viewer/2022021316/577cc3441a28aba71195767c/html5/thumbnails/16.jpg)
8/10/2019 90-005-0017_X02 - MBP_ACDC Power Supply Manual
http://slidepdf.com/reader/full/90-005-0017x02-mbpacdc-power-supply-manual 16/16
Matchbox AC-DC Supply
Doc. 90-005-0017 Rev. X02 Page 16 of 16
J3 – AC Input
Mating Connector: C016 20D003 110 12
J3 – AC Input PinoutPin Signal Signal Type
1 Line2 No Connect
3 Neutral
GND GND
J3 – M&C Input Pin Layout
1
3
G
2
Connector as
viewed from
the front face