! Important Notice on Product Safety
DANGER - RISK OF ELECTRICAL SHOCK OR DEATH - FOLLOW ALL INSTALLATION INSTRUCTIONS.
The system complies with the standard EN 60950 / IEC 60950. All equipment connected to the system mustcomply with the applicable safety standards.Hazardous voltages are present at the AC power supply lines in this electrical equipment. Some components mayalso have high operating temperatures.Failure to observe and follow all installation and safety instructions can result in serious personal injuryor property damage.Therefore, only trained and qualified personnel may install and maintain the system.
The same text in German:
Wichtiger Hinweis zur Produktsicherheit
LEBENSGEFAHR - BEACHTEN SIE ALLE INSTALLATIONSHINWEISE.
Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Alle an das System angeschlossenenGeräte müssen die zutreffenden Sicherheitsbestimmungen erfüllen.In diesen Anlagen stehen die Netzversorgungsleitungen unter gefährlicher Spannung. Einige Komponentenkönnen auch eine hohe Betriebstemperatur aufweisen.Nichtbeachtung der Installations- und Sicherheitshinweise kann zu schweren Körperverletzungen oderSachschäden führen.Deshalb darf nur geschultes und qualifiziertes Personal das System installieren und warten.
Caution:This equipment has been tested and found to comply with EN 301489. Its class of conformity is defined in tableA30808-X3247-X910-*-7618, which is shipped with each product. This class also corresponds to the limits for aClass A digital device, pursuant to part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference when the equipment isoperated in a commercial environment.This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accor-dance with the relevant standards referenced in the manual “Guide to Documentation”, may cause harmful inter-ference to radio communications.For system installations it is strictly required to choose all installation sites according to national and local require-ments concerning construction rules and static load capacities of buildings and roofs.For all sites, in particular in residential areas it is mandatory to observe all respectively applicable electromagneticfield / force (EMF) limits. Otherwise harmful personal interference is possible.
Trademarks:
All designations used in this document can be trademarks, the use of which by third parties for their own purposescould violate the rights of their owners.
Copyright (C) Siemens AG 2005.
Issued by the Communications GroupHofmannstraße 51D-81359 München
Technical modifications possible.Technical specifications and features are binding only insofar asthey are specifically and expressly agreed upon in a written contract.
A30808-X3247-L22-6-7618 3
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
Reason for UpdateSummary:
Sixth Edition for Release BR 7.0
Details:
Chapter/Section Reason for Update
1 The Chapter Has Been Improved
3 The Chapter Has Been Improved
Issue HistoryIssue
Number
Date of issue Reason for Update
1 07/2003 First Edition for New Release BR 7.0
2 12/2003 Second Edition for Release BR 7.0
3 03/2004 Third Edition for Release BR 7.0
4 08/2004 Fourth Edition for Release BR 7.0
5 06/2005 Fifth Edition for Release BR 7.0
6 09/2005 Sixth Edition for Release BR 7.0
4 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
A30808-X3247-L22-6-7618 5
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
This document consists of a total of 70 pages. All pages are issue 6.
Contents
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91.1 Main Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.2 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2 Hardware Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142.1 Board Redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182.1.1 AC/DC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182.1.2 Core . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182.2 Rack Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3 Module Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253.1 Core (COBA and COSA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263.1.1 Core Basis (COBA). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273.1.2 Core Satellite (COSA). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293.1.3 Core Link Extension (COREXT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293.2 Carrier Unit (CU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303.3 EDGE Carrier Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323.4 GMSK Carrier Units (GCU). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343.5 Carrier Unit Output Power Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 353.6 Duplexer Amplifier Multicoupler (DUAMCO). . . . . . . . . . . . . . . . . . . . . . . . 353.7 Flexible Duplexer Amplifier Multicoupler (FDUAMCO) . . . . . . . . . . . . . . . . 363.8 Co-Duplexer and Multicoupler Extension for 8:2 (COAMCO8). . . . . . . . . . 383.9 Dual Integrated Amplifier Multicoupler (DIAMCO) . . . . . . . . . . . . . . . . . . . 383.10 Filter Combiner (FICOM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383.11 Tower Mounted Amplifier (TMA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 393.12 High Power Duplexer Unit (HPDU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 393.13 DC Panel (DCP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 393.14 DC Link Equipment Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 403.15 Alarm Collection Terminal (ACT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 403.16 AC/DC Converter (AC/DC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 413.16.1 DC and Battery Controller (DCBCTRL) . . . . . . . . . . . . . . . . . . . . . . . . . . . 413.17 Overvoltage Protection and Tracer (OVPT) . . . . . . . . . . . . . . . . . . . . . . . . 413.18 Abis Connection Module (ABISCON) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 423.19 Abis Link Equipment (LE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 423.20 Cover Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 423.21 Backup Battery (BATTERY) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 423.22 Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 433.23 Heater Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
4 Antenna Combiners and Receiving Paths . . . . . . . . . . . . . . . . . . . . . . . . . 464.1 Methods of Combining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 464.1.1 TX Attenuation of Combiner Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 564.1.2 DUAMCO - DIAMCO GAIN (RX Path) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 574.1.3 FDUAMCO GAIN (RX Path) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 584.1.4 Parameters of Tower Mounted Amplifier (TMA) . . . . . . . . . . . . . . . . . . . . 594.1.5 Examples for BTSE Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
6 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
4.2 FCC Issues (for US Market Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
5 Power Supply and Battery Backup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 685.1 Support of Emergency Operation for 3rd Party BBU System . . . . . . . . . . . 68
6 Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
A30808-X3247-L22-6-7618 7
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
IllustrationsFig. 2.1 BS-240 II indoor Cabinet (Base Rack). . . . . . . . . . . . . . . . . . . . . . . . . . 14
Fig. 2.2 BS-241 II outdoor Cabinet (Base Rack). . . . . . . . . . . . . . . . . . . . . . . . . 15
Fig. 2.3 Functional Blocks of the BS-240/241 II . . . . . . . . . . . . . . . . . . . . . . . . . 16
Fig. 2.4 Redundant COREs and their Interfaces . . . . . . . . . . . . . . . . . . . . . . . . 18
Fig. 2.5 BS-240 II Base Rack and 2 Extension Racks . . . . . . . . . . . . . . . . . . . . 20
Fig. 2.6 BS-241 II Base Shelter and 2 Extension Shelters . . . . . . . . . . . . . . . . . 21
Fig. 2.7 Possible Configuration of Service1-Rack. . . . . . . . . . . . . . . . . . . . . . . . 22
Fig. 2.8 Possible Configuration of Service2-Rack. . . . . . . . . . . . . . . . . . . . . . . . 23
Fig. 2.9 BS-240/241 II Fully Equipped with 24 Carriers . . . . . . . . . . . . . . . . . . . 24
Fig. 3.1 Connections of Major Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Fig. 3.2 COBA internal architecture. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Fig. 3.3 Core Satellite Board (COSA) internal architecture. . . . . . . . . . . . . . . . . 29
Fig. 3.4 System with COBA4P12 and COREXT. . . . . . . . . . . . . . . . . . . . . . . . . 30
Fig. 3.5 Internal Components of the Carrier Unit. . . . . . . . . . . . . . . . . . . . . . . . 31
Fig. 3.6 FDUAMCO Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Fig. 3.7 Example of Battery Backup Systems Connected to the AC/DC . . . . . . 43
Fig. 4.1 Overview of Combining Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Fig. 4.2 DUAMCO 2:2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Fig. 4.3 DUAMCO 4:2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Fig. 4.4 DUAMCO 8:2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Fig. 4.5 FICOM 8:1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Fig. 4.6 DIAMCO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Fig. 4.7 HPDU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Fig. 4.8 Configuration with HPDU, DUBIAS and TMA . . . . . . . . . . . . . . . . . . . . 54
Fig. 4.9 Configuration with Diplexer (Example) . . . . . . . . . . . . . . . . . . . . . . . . . 55
Fig. 4.10 Multi-cell (3,3,2): with 3 DUAMCO 4:2 . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Fig. 4.11 Multi-cell (3,3,2): with 2 DUAMCO 4:2 and 1 DUAMCO 2:2 . . . . . . . . . 61
Fig. 4.12 Single-cell (8,0,0): with FICOM and DIAMCO . . . . . . . . . . . . . . . . . . . . 62
Fig. 4.13 Single-cell (8,0,0): with 2 DUAMCO 4:2. . . . . . . . . . . . . . . . . . . . . . . . . 62
Fig. 4.14 Multi-cell (2,2,2): with 3 DUAMCO 2:2 . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Fig. 4.15 FDUAMCO Configuration 2:2 or 4:2 . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Fig. 4.16 Configuration of FDUAMCO / COAMCO8 . . . . . . . . . . . . . . . . . . . . . . . 64
Fig. 4.17 Single-cell (11...16,0,0): FICOMs, DIAMCOs and HPDUs in 2 Racks. . 65
8 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
TablesTab. 1.1 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Tab. 1.2 Frequency Bands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Tab. 3.1 Units and Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Tab. 3.2 Carrier Unit Output Power Level (Typic. and Guarant. Values) per TRX 35
Tab. 4.1 Insertion loss of FICOMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Tab. 4.2 Insertion loss of FDUAMCOs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Tab. 4.3 Insertion loss of DUAMCOs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Tab. 4.4 Insertion loss of HPDU and TMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Tab. 4.5 Parameters of DUAMCO - DIAMCO. . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Tab. 4.6 Parameters of FDUAMCO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Tab. 4.7 Parameters of 900 MHz Tower Mounted Amplifier . . . . . . . . . . . . . . . . . 59
Tab. 4.8 Parameters of 1800 MHz Tower Mounted Amplifier . . . . . . . . . . . . . . . . 60
Tab. 4.9 Maximum RF Power Output Values at Antenna Port . . . . . . . . . . . . . . . 66
Tab. 4.10 Maximum RF Power Output Values at Antenna Port . . . . . . . . . . . . . . . 67
A30808-X3247-L22-6-7618 9
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
1 IntroductionThe BS-240/241 II is an evolution of the existing BSS products. Some modificationshave been introduced in the mechatronics which represent the latest state of tech-nology.The RF performance of the BTSs is not affected by the modifications.The architectureof BS-240/241 II provides maximum flexibility to develop higher capacity BTSs withreduced volume and an expanded number of 24 TRXs in 3 Racks with a modularity of8 TRXs per Rack. Any operation for rack extension or TRX substitution doesn’t involveservice interruption. The provision of a full spectrum of combining equipment allows highpower and minimized number of antennas. High receiver sensitivity is also guaranteed.
The modular architecture and the flexible internal structure, enables the BS-240/241 IIto provide GSM features such as EDGE; this platform ensures that network evolution isas smooth as possible.
The use of the latest technology reduces power consumption and improves reliability;the reliability is also increased by the redundancy of all core modules. Easy integrationis possible in the already installed sites, for the backward compatibility with existingSIEMENS SBS systems. High Site efficiency is assured for composite transmit powerwith minimal footprint requirements.
Homogenous service throughout the network is assured by common BTS SW runningon all the platforms.
The BS-240/241 II primarily consists of:• Carrier oriented boards called Carrier Unit (CU),• Core boards COSA, COBA and• Combining equipment
10 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
1.1 Main FeaturesThe BS-240/241 II is designed for max. 24 Carriers in 3 Racks/Shelters plus ServiceRacks/Shelters, if needed. Service Racks/Shelters can be configured to accommodateBackup Batteries and Link Equipment. A Service Rack/Shelter can be equipped withAC/DC Converters. Easy Rack/Shelter extension is possible with one or two ExtensionRacks/Shelters.
The BS-240/241 II can be configured for the systems GSM 850, GSM 900, GSM 1800and GSM 1900 with the following configurations:– Single band– Dual band: GSM 900, GSM 1800; GSM 900, GSM 1900; GSM 850, GSM 1800 and
GSM 850, GSM 1900– Mixed cell configuration to enlarge GSM 900 cells with GSM 1800 frequencies, or
GSM 850 cells with GSM 1900 frequencies.– Single cell– Multi cell
Up to 6 cells per Rack and up to 12 cells per BTSE can be supported. A special case isthe feature “concentric cell”; one cell with 2 supply areas (inner and complete area). Thisfeature can be used in omnicells as well as in multicells with sectors.
The following combining options are supported:– Antenna combining with duplexers (DUAMCO) can be applied for 2, 4 and 8
Carriers. RF amplifier and multicoupler for the RX path are integrated– Antenna combining with duplexers (FDUAMCO) can be applied for 2, 4 and 8
Carriers. RF amplifier and multicoupler for the RX path are integrated– Antenna combining with duplexers (FDUAMCO and COAMCO) can be applied for 8
Carriers. RF amplifier and multicoupler for the RX path are integrated– Antenna combining with Filter Combiners (FICOM) is possible for up to 8 Carriers
onto one TX antenna– Cascading of multicoupler equipment (DIAMCO) is possible for up to 24 Carriers– High Power Duplexer (HPDU) for reduction of the necessary numbers of antennas
in case of FICOM per cell for up to 8 Carriers can be applied– Every BTSE has core equipment in the Base Rack/Shelter– Mixed Configurations of Cells/Sectors applying all types of carrier units: normal
Carrier Units (CU) and EDGE Carrier Units (ECU) .
Traffic Channels:– Full-Rate (FR)– Half-Rate (HR)– Enhanced Full-Rate (EFR)– Adaptive Multi Rate Codec (AMR)
Services:– GPRS– HSCSD– EDGE
Frequency Hopping:– Baseband– Synthesizer
Redundancy:– Support of Core Redundancy– Support of BCCH Redundancy
A30808-X3247-L22-6-7618 11
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
Abis interface configurations:– Star, cross connect, loop and multidrop configurations are possible– Change of PCM line configuration from star to multidrop or loop and vice versa is
possible without any interruption of service
External Abis link media can be connected:– Wire– Fiber optic– Micro-Wave
12 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
1.2 Technical DataThe BS-240/241 II family with 24 transceivers can be supplied in the following versions:– BS-240 for indoor installation.– BS-241 for outdoor installation ( integrated power supply, battery, link equipment.)
BS-240/241 II consist in a BTS architecture, with:- 1 Base Rack- Up to 2 Extension Racks- Up to 4 Service Racks (1 Service1A and 3 Service2).
Characteristics BS-240 (indoor) BS-241 (outdoor)
Max. TRX per BTSE 24 24
(in more than one Rack)
Max. TRX per cell 24 24
(in more than one Rack)
Dimensions (mm) (HxWxD) 1600x600x450 (5’3”x2’x1’6”) 1750x700x650 (5’9”x2’4”x2’2”)
(Base Racks) (incl. Plinth)
Volume net 432 l 705 l796 l (incl. Plinth)
Typical Power Consumption Base Rack 1370 W with CU1950 W with ECU
1370 W with CU1950 W with ECU
Typical Power Consumption Extension Rack 1285 W with CU1860 W with ECU
1285 W with CU1860 W with ECU
Weight of Basic Rack in typical Configuration ca. 190 kg (419 Lbs) ca. 240 kg (529 Lbs)
Weight of Extension Rack in typical Configu-ration
ca. 190 kg (419 Lbs) ca. 240 kg (529 Lbs)
Weight of Service 1 in Configuration: AC/DC;F:Battery 1x (type A400/85)
ca. 264 kg (582 Lbs) ca. 314 kg (692 Lbs)
Weight of Service 2 in Configuration:F:Battery 3x (type A400/85)
ca. 490 kg (1080 Lbs) ca. 540 kg (1190 Lbs)
Temperature Range -5 °C to + 45 °C+23 °F to +113 °F
-33 °C to + 50 °C-27 °F to + 122 °F
Tab. 1.1 Technical Data
A30808-X3247-L22-6-7618 13
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
Frequency-Band Uplink (MHz) Downlink (MHz)
GSM 850 824.2 - 848.8 869.2 - 893.8
P-GSM 900 (Primary) 890.2 - 914.8 935.2 - 959.8
E-GSM 900 (Extension) 880.2 - 914.8 925.2 - 959.8
PS-GSM 900 (Shifted to E-GSM) 880.2 - 905.0 925.2 - 950.0
R-GSM 900 (Railway) 876.2 - 914.8 921.2 - 959.8
GSM-RE 900 (Railway Extension) 876.2 - 901.0 921.2 - 946.0
GSM 1800 1710.2 -1784.8 1805.2 -1879.8
GSM 1900 1850.2 -1909.8 1930.2 -1989.8
Tab. 1.2 Frequency Bands
14 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
2 Hardware ArchitectureThe BS-240/241 II is designed to achieve commonality of boards to serve both GSM850, GSM 900 with its different deviates (GSM 1800, GSM1900) and standards selectedfor mobile communication systems. Fig. 2.1 shows the indoor Base Rack Cabinet.Fig. 2.2 shows the outdoor Base Rack Cabinet.
Fig. 2.1 BS-240 II indoor Cabinet (Base Rack)
A30808-X3247-L22-6-7618 15
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
Fig. 2.2 BS-241 II outdoor Cabinet (Base Rack)
16 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
The BTS functional blocks of the BS-240/241 II are shown in Fig. 2.3
Fig. 2.3 Functional Blocks of the BS-240/241 II
CU 7
CU 0
CU 7
Base Rack
Service Rack
DUAMCO CU 0
COSA
ACTM
CC-Links
FICOM
DIAMCO
HPDU
4xTX
RX
RXDIV
4xTX
RX
RXDIV
ACTC ACTP
LE 0 LE 1
BATTERY
TMA
DCB-
ACP
CTRL
ACTC
FAN
Cell 0
Cell 1
FICOM
DIAMCO
4xTX
4xTX
RX
RXDIV
Cell 1
RX
RXDIV
RX
RXDIV
ACTC ACTP
FAN
to next ext. rack
RXCA1RXCA0
AC/DC
DCP
DCP
DCP
Extension Rack
Cascading
DUBIAS
COBA
2 PCM
Ext. Sync.
2 PCM
4 PCM
Abis
Sync.
Abis
TMA
FAN
TMA
TMA
OVPT
OVPT
CAN BUS
A30808-X3247-L22-6-7618 17
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
The architecture of BS-240/241 II provides maximum flexibility to develop large andsmall BTSs.
The BS-240/241 II mainly consists of:– carrier oriented boards called Carrier Unit (CU),– core boards (COSA, COBA) and– combining equipment
The communication between the CU and CORE modules is provided by means of bi-directional CC-link.
The communication between all other modules and the CORE Unit is provided by theCAN bus.
AC/DC AC/DC converter DCBCTRL DC and Battery ControllerACP AC Panel DCP DC PanelACTC Alarm Collection Terminal Connection module DIAMCO DI(2) Amplifier MulticouplerACTM Optional Alarm Collection Terminal for Master Rack DUAMCO Duplex Amplifier MulticouplerACTP Alarm Collection Terminal for Slave Rack FICOM Filter CombinerCAN Controller Area Network HPDU High Power DuplexerCOBA Core Basis LE Link EquipmentCOSA Core Satellite TMA Tower Mounted AmplifierCU Carrier Unit
18 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
2.1 Board RedundancyRedundancy in the SBS ensures survival of the system even in the event of multiple fail-ures. Modular architecture, in conjunction with the concept of split functions, guaranteesmaximum survivability with a minimum of additional hardware.
2.1.1 AC/DCUp to 6 AC/DC converters (only one Frame) can be equipped in the Service1A Rackwhich provide n+1 redundancy. AC/DC converters work in load sharing, but n AC/DCare able to supply the whole BS-240/241 II .
2.1.2 CoreThe Core can consist of up to 2 (without redundancy) or up to 4 (with redundancy)boards, which have a common backplane. The block diagram depicts the CORE redun-dancy and the embedding of the active and the passive CORE into the BTS, and theinterrelation of both COREs.
Fig. 2.4 Redundant COREs and their Interfaces
Both COREs (COBA0, COSA0 and COBA1, COSA1) have link interfaces to the Abislines, but only one (the active CORE) can be connected.
Both the active and the passive CORE have links to the carrier units (CU); in reverse,each CU is linked with both COREs. The traffic data are transmitted transparentlythrough the active CORE. Signal processing takes place only within the CUs.
The endpoints of each link are built up by SELIC ASICs (note: one SELIC containsdouble functionality), where on the CU, one SELIC serves two COREs. In the case of aswitch over, the SELICs on the active CORE are disabled by the switch logic and theSELICs on the passive one are enabled.
The RD interface (redundancy interface) is realized as a 2 Mbit/s HDLC link whichprovides a communication interface between the two main processors.
CUSELIC
SELICRDInterf.
SwitchLogic
CORE 0CLK
Route Clock
Redundancy Link
Switch Logic Link
Route Clock(Frame Sync)
ABISCAN
LMT
µP
CUSELIC
CUSELIC
SELIC SELIC SELICRD
Interf.
SwitchLogic
CORE 1CLK
Route Clock
µP
SELICSELIC
PCMSwitch
PCMSwitch
PCMLinkTerm.
PCMLinkTerm.
A30808-X3247-L22-6-7618 19
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
The CLK of the active CORE is connected with the one on the passive CORE. It allowsthe passive CLK to be synchronized to the active one.
NOTE: the redundancy is implemented in a cold-standby mode, i.e., all calls will get lostif a CORE switch over occurs.
2.2 Rack ConfigurationThe BS-240/241 II family, with 8 transceivers per Rack, is expandable up to 24 trans-ceivers in 3 Racks and can be supplied in two versions:– a BS-240 for indoor installation– a BS-241 for outdoor installation
There are 4 different types of Rack:– Base Rack/Shelter (with Core modules)– Extension Rack/Shelter (for more then 8 CU’s)– Service1 Rack/Shelter (with AC/DC modules)– Service2 Rack/Shelter (for LE and batteries)
It is possible to connect up to 3 Racks/Shelters together (1 Base Rack, 2 ExtensionRacks; the more possible Racks/Shelters called Service Rack/Shelter are not part of aRack Extension in the proprietary sense) that realizes then the performance of a 24 TRXBTSE as shown in Fig. 2.5 and Fig. 2.6:
20 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
Fig. 2.5 BS-240 II Base Rack and 2 Extension Racks
ACOM
0
ACOM
1
ACOM
2
ACOM
3
DC-PANELACT-C
CU
2
CU
3
CU
6
CU
7
MU
CO
0
MU
CO
1
CU 0
CU 1
CU 4
CU 5
BS-240SIEMENS
ACOM
0
ACOM
1
ACOM
2
ACOM
3
CU
2
CU
3
CU
6
CU
7
MU
CO
0
MU
CO
1
CU
0
CU
1
CU
4
CU
5
BS-240SIEMENS
CO
BA
0C
OS
A 0
CO
BA
1C
OS
A1
FAN 0 FAN 1
ACOM
0
ACOM
1
ACOM
2
ACOM
3
DC-PANELACT-C
CU
2
CU
3
CU
6
CU
7
MU
CO
0
MU
CO
1
CU 0
CU
1
CU 4
CU 5
BS-240SIEMENS
FAN 0 FAN 1
DC-PANELACT-C
FAN 0 FAN 1
FAN 2 FAN 3
FAN 4 * FAN 5*
FAN 2 FAN 3
FAN 4* FAN 5*
FAN 2 FAN 3
FAN 4* FAN 5*
* not present in case of BTSE with reduced number of fans
A30808-X3247-L22-6-7618 21
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
Fig. 2.6 BS-241 II Base Shelter and 2 Extension Shelters
Fig. 2.9 shows the max possible configurations. The Base Rack and the ExtensionRacks can be located physically in any position.
The Service Rack (see Fig. 2.7 and Fig. 2.8 for possible configuration) satisfies variousapplications depending on number of CU units configured and/or number and kind ofNetwork termination equipment provided and the Battery Backup time required.
CU
2
CU
3
CU
6
CU
7
MU
CO
0
MU
CO
1
CU
0
CU
1
CU
4
CU
5
BS-241SIEMENSC
OB
A 0
CO
SA
0C
OB
A 1
CO
SA
1DC-PANEL
ACT-C
FAN 0 FAN 1
FAN 2 FAN 3
FAN 4* FAN 5*
ACOM
0
ACOM
1
ACOM
2
ACOM
3
CU
2
CU
3
CU
6
CU
7
MU
CO
0
MU
CO
1
CU
0
CU
1
CU
4
CU
5
BS-241SIEMENS
DC-PANELACT-C
FAN 0 FAN 1
FAN 2 FAN 3
FAN 4* FAN 5*
ACOM
0
ACOM
1
ACOM
2
ACOM
3
CU
2
CU
3
CU
6
CU
7
MU
CO
0
MU
CO
1
CU
0
CU
1
CU
4
CU
5
BS-241SIEMENS
DC-PANELACT-C
FAN 0 FAN 1
FAN 2 FAN 3
FAN 4* FAN 5*
ACOM
0
ACOM
1
ACOM
2
ACOM
3
* not present in case of BTSE with reduced number of fans
22 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
Fig. 2.7 Possible Configuration of Service1-Rack
A30808-X3247-L22-6-7618 23
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
Fig. 2.8 Possible Configuration of Service2-Rack
On the digital side there is an extension of the CC links (connection between Core Back-plane and the CU’s not housed in the Base Rack) and the CAN Bus.
24 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
Fig. 2.9 BS-240/241 II Fully Equipped with 24 Carriers
For the BS-241 II outdoor cabinet only one type of the Shelter exists to be used for alloutdoor Base Shelter, Extension Shelters, Service1A and Service2 Shelters.
BS-241 II - DC (DC supplied version of BS-241 II)
The Shelter of this BTS version are externally DC supplied; in this application only usinga Service 2 Rack without Service 1 Rack.
Extension Rack
Base Rack
Service1A Rack
Service2 Rack
Extension Rack
A30808-X3247-L22-6-7618 25
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
3 Module Description
Name Freq.Var.
Remarks
Core modules:COBACOSACOREXT
Core basisCore satelliteCore link extension board
no Up to 8 PCM lines with COBA and COSAequipped (COBA and COSA can beequipped only in the Base Rack/Shelter).
Carrier related modules:CUxECUx
Carrier unit yes Carrier unit and EDGE carrier unit canbe equipped in the Base and ExtensionRacks/Shelters.
Antenna system modules:DUAMCO / FDUAMCO2xDUAMCO / FDUAMCO4xDUAMCO / FDUAMCO8xDIAMCOxFICOMBxFICOMXxTMAxHPDUxCOAMCO8
Duplexer 2:2Duplexer 4:2Duplexer 8:2Diversity multicouplerFilter combiner (base)Filter combiner (extension)Tower mounted amplifierHigh power duplexerCo-Duplexer and Multicou-pler Extension for 8:2
yes Antenna system modules can beequipped in the Base and ExtensionRacks/Shelters.DIAMCO, FICOM and HPDU are notavailable for the GSM 1900 band.DUAMCO / FDUAMCO and HPDUworking in shifted primary GSM 900 bandare available.A Diplexer can be used in all caseswhere GSM 900 and GSM 1800, GSM1900 and GSM 850, Feeder Cableshave to be installed in parallel.
Alarm collection modules:ACTC (part of DC-Panel)ACTMACTP
Alarm Collection Terminals no ACTC is equipped in every Rack/Shelter.ACTM can be equipped in the BaseRack/Shelter. ACTP can be equipped inthe Extension or Service Racks/Shelters.
Power supply modules:AC/DCDCBCTRL
AC/DC converterDC battery controller
no AC/DC controller used for AC power andsupervision of the ACDC converter canbe equipped in the Service Racks/Shel-ters.
OVPTOVPTCOAXABISCON
Over Voltage Protectionand tracerAbis Connection Module
no 100 Ω / 120 Ω balanced line75 Ω coaxial line. The OVTP is anoptional feature.ABISCON can be installed as alternativeto the OVPT
Abis Link Equipment:LE
Link Equipment no Link Equipment can be equipped inService1 and Service2 Racks/Shelters
Cover Parts:CP:ACOMCP:CUCP:ACDCCP:DIAMCOCP:COBA, COSACP:ACT
Cover Parts have to beinserted if the respectiveactive module is notneeded in a configuration
no the air flow inside the Frame or Shelter isnot affected
Tab. 3.1 Units and Modules
26 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
3.1 Core (COBA and COSA)The Core has the following tasks inside of the BTSE:– local controlling of the entire BTSE– generation of system clocks– providing of up to 8 Abis-interfaces to BSC or other BTSEs– routing of Abis-data to up to 24 CUs– providing an interface to the LMT Evolution/OMT– handling and processing of O&M-messages
Therefore, the Core can consist of up to 2 (without redundancy) or up to 4 (with redun-dancy) boards. The following illustration shows the connection of the CU units and Abislines to the CORE units:
Battery Backup Battery systems no up to 4 battery systems can be equipped(only in the Service1A or Service2Racks/Shelters)
Fan Central Fan unit no for forced convection cooling
Heater:MEF Single Heater
no Heater can be equipped in all types ofShelters
Shelter Shelter of the Cabinet no Base, Extension, Service1A andService2 with MEF
Name Freq.Var.
Remarks
Tab. 3.1 Units and Modules
A30808-X3247-L22-6-7618 27
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
Fig. 3.1 Connections of Major Modules
If more then 12 Carrier Units in the Base Rack or an Extension Rack are installed inaddition to the COBA module, a COSA module is mandatory.
Hot Plug-in: A Hot Plug-in of the Core-boards (COBA and COSA) is possible. Thismeans that these boards can be plugged in/out with voltage switched on and no otherHW inside of the Rack is disturbed (no loss of data on other boards) or a board isdestroyed.
After plug-in of a Core-board, this board is in the reset-state and all bus-drivers ofexternal busses are in tristate. These drivers will be enabled not before initialization ofthe devices, which serve the external busses.
3.1.1 Core Basis (COBA)Two COBA boards are developed:• COBA2P8• COBA4P12
The first digit gives the number of Abis-Interfaces, the following letter the kind ofAbis-interface (e.g. P for PCM30/24), and the following digit the number of CU-inter-faces, e.g., COBA2P8 (2 PCM30/24 Abis-interfaces, 8 CU interfaces).
The COBA4P12 board permits to optimise the split of CU-links and Abis interfaces.
The primarily concepts of the COBA2P8 / COBA4P12 cards are:– Low impact on O&M software– Pin compatibility
Abis Abis
COBA COSA COBA red. COSA red.
Abis Abis
Abis
other
interfaces
Extension Racks
CUs
CUOVPT
8/12
8/6
8/6
Base Rack
CU
CC-Link CC-Link CC-Link CC-Link
6/42/4
iA COBA-board can only be pulled out, if before the COSA-board is pulled out
28 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
– Maintenance of the current functionality (same feature, same redundancy concept)– Maintenance of the current LEDs signalling philosophy
The COBA is the central board of the core. The main components of this board are theBase Core Controller (BCC), the Advanced CLock Generation (ACLK), the SErial LinkInterface Controller (SELIC) that manage the external interface towards the CarrierUnits, the PCM30/24 Abis interfaces, the internal system alarm interface and also aninterface to one satellite board (COSA) to expandi the COBA.
The most important functionalities of the COBA are the local controlling of the BTSplus,the generation of the system’s clocks, the management of all the internal/external inter-faces and the routing of data to the CU. In addition the COBA handles all the O&Mmessages and it manages the SW download functionality.
To fulfill the CORE redundancy aspects a redundant COBA can be installed. It works instandby mode. In case of a serious fault to the active COBA, the redundancy algorithmswitches over the redundant one. The redundancy implemented is a "cold" one. Thismeans that when the "cold" COBA goes in service there is no synchronization of datawith the faulty one, the service is interrupted during the transition phase and all theactive calls are therefore lost. In the next "Fig. 3.2 COBA internal architecture." theinternal components of the COBA are represented.
Fig. 3.2 COBA internal architecture.
The Advanced CLock Generation (ACLK) generates also the system specific timingsignals that are distributed to the external Carrier Units (CU).
iA mixed configuration with COBA2P8 and COBA4P12 in the same BTSE is notsupported.
Abis1
Abis2
SA
T-I
nter
face
DC/DC Converter
SRAM
RDLLOGIC
WATCHDOG
EEPROMsA/D-Conv. Mux
CAN-BUS, ALARMS LEDs, Redundancy Control,
Route clock
external CLK sync
CONTROLLER
BASE CORE ADVANCED
CLOCK
GENERATOR
Links to
LMT Interface
to
COSA
AlarmInterface
Flash Memory Input/Output PCM Switch
Internal Core Controller Bus
CUs
SERIALLINK
INTERFACECONTROLLER
A30808-X3247-L22-6-7618 29
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
3.1.2 Core Satellite (COSA)Two COSA boards are developed:• COSA6P16• COSA4P12
The first digit gives the number of Abis-Interfaces, the following letter the kind ofAbis-interface (e.g. P for PCM30/24), and the following digit the number of CU-inter-faces, e.g., COSA4P12 (4 PCM30/24 Abis-interfaces, 12 CU interfaces).
The primarily concepts of the COSA6P16 / COSA4P12 cards are:– Low impact on O&M software– Maintenance of the current functionality (same feature, same redundancy concept)– Pin compatibility– Maintenance of the current LEDs signalling philosophy
The main task of the COSA board is to increase the number of the Abis-interfaces andCC-links of the Core Board (COBA) in order to provide in total up to 8 PCM30/24 portsand up to 24 Carrier Units (CU).
The COSA is controlled via a satellite interface by the COBA and receives theworking-clock from the COBA.
The next "Fig. 3.3 Core Satellite Board (COSA) internal architecture" shows the internalcomponents and interfaces of the COSA board:
Fig. 3.3 Core Satellite Board (COSA) internal architecture
3.1.3 Core Link Extension (COREXT)The COREXT board has to be used inside the COSA slot if no COSA is used and morethan 2 PCM interfaces or 8 CC-links (8 CUs ) shall be used with the COBA4P12.
Internal PCM Bus
Internal Core Controller Bus
SatelliteInterface
To COBA
PCM30/24ports
SerialLinkInterfaceController
To CUs
DC/DC converterRoute ControlPreselector
Bus interface to COBA
PCMSwitch
AbisInterface
30 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
The Core Link Extension board connects 4 CU ports and 2 Abis ports located atCOBA4P12 board via core backplane to the appropriate interfaces.
The COREXT is only a passive board without DC supply interface.
Two external Abis (PCM) lines are connected directly to the COREXT board. These Abis(PCM) lines are routed to the COBA4P12.
If Core redundancy is required, two COREXT boards shall be installed.
To apply the feature cross connect, either COSA4P12 or COREXT board must beinstalled in Base Rack together with COBA4P12.
Fig. 3.4 System with COBA4P12 and COREXT
3.2 Carrier Unit (CU)The Carrier Unit (CU) is composed by an analogue receive and transmit part with aSynthesiser and Power Amplifier (PA), by a SIgnal PROcessing unit (SIPRO) as well asa Power Supply Unit (PSU). It has two receive inputs, one for the normal path, the otherfor the diversity path. The CU contains all the functions that make up one carrier andinclude synthesiser hopping and advanced equalizer functions for high speed applica-tions.Besides it takes care for all carrier oriented tasks. In the uplink (UL) direction twoRF signals (diversity) are received and finally converted into TRAU frames (PCU framesfor GPRS) and signalling data. In the downlink (DL) direction, TRAU frames and signal-ling data are received and converted into a GMSK modulated RF signal, which is ampli-fied to the desired power level.
There are three variants of the CU for the different frequency bands R-GSM 900, GSM1800 and GSM 1900. The differences of the variants arise mainly on the Power Ampli-fier.
A30808-X3247-L22-6-7618 31
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
Fig. 3.5 Internal Components of the Carrier Unit.
Power Amplifier and Transceiver Unit (PATRX)
The Power Amplifier and Transceiver Unit provides the main analog functions of theCU:– It receives the two (diversity) RF signals from the antenna combining equipment and
converts them down to IF. The downconverted RF signals are then transmitted toSignal Processing Unit where they are sampled and digitally downconverted tobaseband.
– It receives the GMSK modulated signal from the Signal Processing Unit. The signalis then I/Q modulated, upconverted, levelled, power amplified, and transmitted to theantenna combining equipment.
– It supports the synthesizer frequency hopping.– It provides an RF loop between downlink and uplink path for the unit test of the CU.
Signal Processing Unit (SIPRO)
The Signal Processing Unit contains all the digital functions of the carrier unit, includingthe following:• Signal Processing in uplink and downlink.• Control of RF on the Power Amplifier.• Baseband and synthesizer hopping.• Channel Control.• Radio Link Control.• O&M parts relevant for the carrier unit.• Link to the Core Board (COBA) via the CC link.
Additionally, also the following analog functions are managed:• Analog to digital conversion (IF).• Digital to analog conversion (baseband).• Management of CU local clock.
Due to the analog functions, the Signal Processing Unit is specific for the differentfrequency variants. (one type for the GSM 900, and one for the GSM 1800, GSM 1900).
Power Supply Unit (PSU)
The Power Supply Unit is the DC/DC converter for the CU for all applications. It gener-ates the voltages +26/28V, +6V (only GSM 1800, GSM 1900), +12V, +5.3V and -5.3V
cc-link
-48V DC
Rx inputs
Tx output
PowerAmplifier
SignalProcessingUnit
Power Supply Unit
32 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
for the analog circuitry and +3.35V for the digital circuitry from a -48V primary inputvoltage. The PSU is mechanically incorporated in the CU.
3.3 EDGE Carrier UnitThe EDGE Carrier Unit (ECU) is a modified CU that uses the same interfaces as theCU but supporting the EDGE functionality in uplink and downlink. In downlink direction,the signalling and traffic data are received from the Core and converted into GMSK or8-PSK modulated signal, which is amplified to the desired power level.With the ECU it is possible to mix EDGE and non EDGE timeslots on the same carrier.
The ECU carries two independent receivers (normal and diversity channel) to providethe antenna diversity function. In uplink direction, the received signal is converted to theIF-band. The IF-band is then converted to a digital GMSK/8PSK-signal.
The mechanical design of ECU is identical to that of CU versions.
The ECU and CU modules may be installed in any kind of mixed configurations. Further,any cell/sector configuration with a mixture of EDGE CU and “normal CUs” can be imple-mented.
The EDGE Carrier Unit (ECU) takes care for all carrier oriented tasks of the BTS. Inuplink (UL) direction, two RF signals (diversity) are received and finally converted intoTRAU or PCU frames and signalling data. In downlink (DL) direction, TRAU or PCUframes and signalling data are received and converted into a GMSK or 8-PSK modu-lated RF signal, which is amplified to the desired power level.
Functional Structure of the EDGE Carrier Unit
The ECU consists of following functional subunits:
EDGE Power Amplifier and Transceiver Unit (EPATRX).
EDGE Signal Processing Unit (ESIPRO).
EDGE Power Supply Unit (EPSU).
EDGE Power Amplifier and Transceiver Unit ( EPATRX)
The EDGE Power Amplifier and Transceiver Unit provides the main analogic functionsof the CU. In uplink direction, two (diversity) preamplified and filtered RF signals arereceived from the antenna combining equipment. These signals are down converted toIF and channel filtered in the RXFE stage. The IF signals are then transmitted toESIPRO, where they are sampled and digitally down converted to baseband. In down-link direction, the GMSK or 8PSK modulated signal is received from the ESIPRO, I/Qmodulated and up converted by the MODUP stage, which also provides the levelling ofthe output power.
The obtained RF signal is then power amplified by the module EPWRST and transmittedto the antenna combining equipment. A part of the transmitted power is fed to themodule PWRDET, which performs the power detection. This signal is used to close thedigital power loop.
The Predistortion Receiver (PDRX) down converts the transmit signal to the TX-IF forthe I/Q-Demodulation and adjusting the predistortion values. The transmitter is linear-ized by means of an adaptive digital predistortion which is applied to the basebandsignals. For the introduction of the ECU,a static predistortion was choosen for lineariza-tion of the transmit path. The HW is able to do adaptive predistortion, which can beinstalled by SW update. EPATRX is able to support synthesizer frequency hopping by
A30808-X3247-L22-6-7618 33
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
the implementation of the synthesizer modules RXLO and TXLO. The unit test of theECU is supported by the module LTL, which provides an RF loop between downlink anduplink path, tested ECU/GCU sends on the chosen test frequency with maximum poweron one timeslot.
EDGE Signal Processing Unit (ESIPRO)
The Signal Processing Unit board of the BTSplus is a part of the EDGE Carrier Unit. Itcontains the following functions of the EDGE Carrier Unit:– Signal Processing in uplink and downlink– Control of RF on EPATRX– Baseband and synthesizer frequency hopping– Channel Control– Radio Link Control– O&M parts relevant for carrier unit– Link to Core via ASIC SELIC– Digital Modulation– Predistortion signal processing– Digital part of Power control– Analog to digital conversion (RXIF)– Digital to analog conversion (TX-baseband, TX-ramping)– Analog to digital conversion (PDRX)– Analog to digital conversion of Diode voltage– Analog to digital conversion of temperature– Local clock of CU
EDGE Power Supply Unit (EPSU)
The EPSU is the DC/DC converter for the ECU for all applications. The EPSU generatesthe voltages +26V/+28V, +12V, +5,3V and -5,3V for the analog circuitry and +3.3V forthe digital circuitry from a -48V primary input voltage.The EPSU is mechanically incor-porated in the ECU.
The EPSU is a slightly modified version of the PSU of the GSM CU. In this document,not all Interface names are changed to EPSU. Therefore, PSU can be seen as asynchronym for EPSU in this document.
34 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
3.4 GMSK Carrier Units (GCU)The GCU is a resembled ECU (the main sub-units are similar) which supports GMSKmodulation only, like the CU.
GCUs and CUs differ in the RF output power value for the GSM 1800 frequency band:
GCU: 54 W; CU: 37 W.
There are different variants of GCUs for the frequency bands GSM 900 and GSM 1800.
The types of GCU are the following:• GCUGV2 GMSK Carrier Unit for GSM 900 MHz• GCUDV2 GMSK Carrier Unit for GSM 1800 MHz
A30808-X3247-L22-6-7618 35
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
3.5 Carrier Unit Output Power LevelThe typical and guaranteed values of RF output power level are listed below for CUs,GCUs and ECUs, dependent on its frequency bands and modulation types (GMSK and8PSK).
3.6 Duplexer Amplifier Multicoupler (DUAMCO)The DUAMCO consists of two identical modules. Each module contains a duplex filter,which combines the RX and the TX path together, to be fed to a common antenna. TheDUAMCO combines 1 (see Fig. 4.2), up to 2 (see Fig. 4.3) or up to 4 (see Fig. 4.4)Carriers to one antenna and consists of two branches with the following elements:• a LNA (Low Noise Amplifier) which takes care of a low system noise figure• an attenuator (in case of installed TMAs, additional gains greater than the cable
losses must be adjusted by means of the attenuator)• a second low noise amplifier• a power splitter which distributes the received band to the CUs (Carrier Units)• a transmit path which consists of:
– an isolator which protects the PAs (Power Amplifiers) inside the CUs from eachother in order to assure the required intermodulation suppression
– a hybrid coupler which provides the reference signal for dynamic and static powercontrol. The corresponding not transmitted power is terminated in a load includinga heat sink (for DUAMCO 4:2 and DUAMCO 8:2)
– an ASU (Antenna Supervision Unit) which is responsible for detecting certainreflection factors at the antenna connector. The ASU detects the VSWR failure
FrequencyBand
Carrier Unit Type TypicalRF Output Power
GuaranteedRF Output Power
GMSK 8PSK GMSK 8PSK
dBm Watt dBm Watt dBm Watt dBm Watt
CU/GCU GSM 900 CUGV3 / V4 47.3 54 -- -- 47.0 50 -- --
GCUGV2 47.3 54 -- -- 47.0 50 -- --
GSM 1800 CUDV3 / V4 45.7 37 -- -- 45.4 35 -- --
GCUDV2 47.3 54 -- -- 47.0 50 -- --
GSM 1900 CUPV4 45.7 37 -- -- 45.4 35 -- --
ECU GSM 850 ECU850HPV2 48.3 68 46.3 43 48.0 63 46.0 40
ECU850V3 / V3A 48.3 68 46.3 43 48.0 63 46.0 40
GSM 900 ECUGV3 / V3A 48.3 68 46.3 43 48.0 63 46.0 40
GSM 1800 ECUDV2 47.3 54 45.3 34 47.0 50 45.0 32
ECUDHPV3 / V3A 48.3 68 45.3 34 48.0 63 45.0 32
GSM 1900 ECUPV2 47.3 54 45.3 34 47.0 50 45.0 32
ECUPHPV2 48.3 68 45.3 34 48.0 63 45.0 32
ECUPHPV3 / V3A 48.3 68 45.3 34 48.0 63 45.0 32
Tab. 3.2 Carrier Unit Output Power Level (Typic. and Guarant. Values) per TRX
36 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
and generates a failure information towards the O&M (CAN bus interface). Thisinformation is subdivided in several levels with the following characteristics:- VSWR < 2 neither generation of warning nor of an alarm- 2 ≤ VSWR ≤ 3 generation of warning 'Antenna not Adjusted'- VSWR > 3 generation of VSWR alarm 'Antenna Faulty'.
and a common part consisting of:• a PDU (Power Distribution Unit) for two TMAs (Tower mounted Amplifier) connected
to the TMAs by means of an antenna feeder cable• an O&M interface which transmits error messages to the BTS core via a slow O&M
bus (CAN bus)
The DUAMCO amplifier has two different operation modes:– the AMCO mode where no TMA is used– in case a TMA is used the DUAMCO is configured in the MUCO mode
The PDU provides the DC power supply and the alarm supervision of the TMAs. Alarmmonitoring is done with a signalling interface between DUAMCO and TMA, modulatedonto a IF carrier at 7.86 MHz.
3.7 Flexible Duplexer Amplifier Multicoupler (FDUAMCO)The combining module FDUAMCO used for CUs, GCUs, ECUs and FCUs wasdesigned for the following configurations:– two cells with one carrier– one cell with up to 2 Carriers– one cell with up to 4 Carriers– one cell with up to 8 Carriers (with COAMCO module)
For each system GSM 850, GSM 900, GSM 1800 and GSM 1900 one type ofFDUAMCO is available.
The types of FDUAMCO are the following:• FDUAMCO850VX Flexible Duplexer Amplifier Multicoupler for GSM 850 MHz
(allows the integration of the SMR filter functionality)• FDUAMCOPGVx Flexible Duplexer Amplifier Multicoupler for P-GSM 900 MHz• FDUAMCOPS5Vx Flexible Duplexer Amplifier Multicoupler for PS-GSM 900 MHz• FDUAMCOEGVx Flexible Duplexer Amplifier Multicoupler for E-GSM 900 MHz• FDUAMCODVx Flexible Duplexer Amplifier Multicoupler for GSM 1800 MHz• FDUAMCOPVx Flexible Duplexer Amplifier Multicoupler for GSM 1900 MHz
Up to BR 7.0 max. 4 TRX can be connected to the FDUAMCO, or 8 TRX withFDUAMCO/COAMCO8 8:2. Each half of the FDUAMCO can be configured in“One-To-One” mode (like DUAMCO 2:2) and “Two-To-One” mode (like DUAMCO 4:2)by means of jumper cables, which bypass the 3 dB hybrid or not. ”One-To-One” meansthat the hybrid is bypassed, “Two-To-One” means that the hybrid is used.
The FDUAMCO has a CAN bus interface and supports one frequency band. (seeFig. 3.6)A mix of 2 frequency bands within one FDUAMCO is not possible. The compatibility ofthe frequency bands of the combiner and the carrier units must be checked by thecustomer.
The FDUAMCO provides identical VSWR alarms and CAN bus connection as knownfrom the DUAMCO modules.
The integrated TMA interface is identical to the interface like in the DUAMCO modules.
A30808-X3247-L22-6-7618 37
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
The use of the integrated hybrid is optional (use of jumper cables).
For more information about the FDUAMCO please refer to page 49.
Fig. 3.6 FDUAMCO Block Diagram
FDUAMCO
Tri-plexer
VSWRPROC
ANT1Testout1
RXout1
RXin1
Tri-plexer
VSWRPROC
ANT0Testout0
RXout0
RXin0
RXCA1RX0 RX2RX1 RX3
RXCA0 RX3RX1RX2RX0
TMASignall.
TMADC/DCConvert.
DC/DCConvert.
PID
CANControl.
DIPSwitch0
DIPSwitch1
Module0 Module1
1 ACOM Slot
TX1 TX0 TX1 TX02 1 4 3 2 1 4 3
3 dB Hybrid3 dB Hybrid
CAN Bus
RX TXFilter Filter
TX RXFilter Filter
LNA LNA
LNALNA
38 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
3.8 Co-Duplexer and Multicoupler Extension for 8:2(COAMCO8)A COAMCO8 unit consist of two identical Modules (0/1), each having a transmit and areceive path. The COAMCO8 is used in conjunction with a FDUAMCO in 4:2 configura-tion to provide an 8:2 configuration. (see Fig. 4.16)
The COAMCO8 combines 2 additional Carriers per module with the 2 Carriers from thefour output of the FDUAMCO.
3.9 Dual Integrated Amplifier Multicoupler (DIAMCO)The installation of a DIAMCO Unit is required to implement two cells/sectors with RXdiversity in a Base or Extension Rack.
For the uplink direction, the DIAMCO module is used to split the RX antenna signal toseveral receiver inputs.Therefore it filters and distributes the received signals to theCarrier Units in one Rack. The DIAMCO consists of two branches constituted by:– a receive filter– a low noise amplifier (LNA) which takes care of a low system noise figure– an attenuator– a second low noise amplifier– a power splitter which distributes the received band to the CUs (Carrier Units)
and a common part constituted by:– a PDU (Power Distribution Unit) for two TMAs (Tower mounted Amplifier) connected
to the TMAs by means of an antenna feeder cable– an O&M interface which transmits error messages to the BTS core via a slow O&M
bus (CAN bus)
The DIAMCO RX amplifier has two different operation modes:– the AMCO mode where no TMA is used– in case a TMA is used the DIAMCO is configured in the MUCO mode
3.10 Filter Combiner (FICOM)With the FICOM, it is possible to combine up to 8 frequencies in downlink direction (TX)in one Rack. For the uplink direction (RX), the DIAMCO has to be used to filter anddistribute the received signals to the Carrier Units. The FICOM consists of remotetunable narrowband filters (TNF). The advantage of this filter combining technique is thevery low insertion loss, if e.g., 8 transmitters are combined to one antenna.
In principle, the FICOM offers the following functions:• RF Functions:
– RF Power Combining– Transmitter Spurious Signal Suppression– Isolation between inputs– Isolation output to input
• Control / Monitoring Functions:– Antenna VSWR alarm thresholds setting and status reporting– Internal Performance Monitoring– Interfacing with BTSE
• LED Display:– Antenna VSWR alarms
A30808-X3247-L22-6-7618 39
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
– Tuning alarms– Presence of DC
• Lightning Protection at the RF output connector (7/16)
3.11 Tower Mounted Amplifier (TMA)The TMA connects the antenna with the BTSE in order to amplify the receive signal andpass through the transmit signal. The TMA contains two duplex filters, each on one RFconnector, to separate and combine the receive and transmit path inside of the TMA.The TMA consists of the following:– RX parts of the duplex filter and– LNA (Low Noise Amplifier) that takes care of a low system noise figure of the RX part– TX parts of the duplex filter
The DC power for the TMA is feed into the triplexer by the PDU (Power Distribution Unit)functionality of the DUAMCO or FDUAMCO or DIAMCO.
The Encoder/Decoder units of the TMA signalling interface generate an alarm for eachTMA separately by supervising the DC current consumption of each unit.
Note: When the TMA is used the DUAMCO or FDUAMCO or DIAMCO works in the socalled MUCO (multicoupler) mode. In the MUCO mode, the DUAMCO or FDUAMCO orDIAMCO mainly works as multicoupler to split the receive signal for the following CUs.
3.12 High Power Duplexer Unit (HPDU)The High Power Duplexer has the task of combining the TX- and the RX-path into oneantenna, in order to minimize the number of antennas when FICOM is used. The HPDUcontains a duplex filter for the transmit frequency band and for the receive frequencyband, but no Low Noise Amplifier in the RX path.
If the TMA shall be used together with a HPDU a so called BIAS-T (DUBIAS) forpowering and signalling of the TMA is required. Up to two HPDU can be integrated ontop of the Rack below the cover and also up to two HPDU could be fit in the gap betweenthe inner side wall and the Frame in the Shelter.
Note: HPDU is available for working in the P-GSM 900, GSM 1800 and GSM-PS 900.
3.13 DC Panel (DCP)The DC Panel contains the circuit breakers to protect the DC power lines for themodules, the ACTP, FAN units, LE units. The LMT Evolution connector is integrated intothe front of the DC panel located in the Base Rack.The DC Mains Supply Unit is located at the EMI-Panel of the BS-240/241 II Base Rack,Extension Rack, and Service 2 Rack.
The DC Mains Supply Unit comprises the lightning protection (optional feature), theEMI-filter, and the terminal clamps for external DC supply cable (-48V, 0V).
The lightning protection element indicates a fault condition at an alarm output (LightningProtection Alarm - LPA). The LPA signal is linked to the Alarm Collection Terminal.
40 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
3.14 DC Link Equipment PanelThe DC Link Equipment Panel provides the distribution of the –48 V supply voltage tothe modules within the BS-240/241 II Service 2 Racks and integrates the required DCbreakers for the different circuits.
If link equipment is installed into Service 1A and Service 2 cabinets then the associatedDC:LE-panel can be equipped with breakers. The LE breakers can be plug-in duringinstallation of link equipment at the BTSE site.
At the front of panel, the high-current clamp terminals are located for connecting the DCsupply lines (-48V, 0V).
The Alarm Collection Terminal module (ACT-C) is also integrated into the DC:LE-Panelassigned to Service 2 cabinet. The ACT-C module is capable for collecting up to 8cabinet alarms, and the alarms generated by fan units, battery temperature sensors,lightning protection alarm (LPA / OVP), and Rack door open sensor.
3.15 Alarm Collection Terminal (ACT)The physical function of the ACT is to transfer the alarm and command signals from thealarm / command connectors of the BTSE subsystem via the CAN BUS to the CoreController. The interface of operator specific alarms (site inputs / outputs) is located inthe Base cabinet. For this purpose, an optional ACT master module (ACTM) is installedinto the Base cabinet.
The ACT functionality is realized by a set of modules:• Processor module -ACTP• Processor module with interface board for external signals -ACTM• Interface module for internal signals -ACTC
The tasks of the ACTP are:• Interface to CAN Bus for alarms collected by ACTC• Rack address adjustment
The ACTM module consists of a processor board and an interface board (ACTA) and isapplied for following tasks:• Iinterface to CAN Bus• Collection of so-called operator available alarms (48 site inputs)• Indoor lightning protection
ACTC is installed once in each cabinet to collect all internal alarms. It has inputs for 16discrete alarm lines: rack door alarm, fan alarms, temperature alarms and internalcabinet alarms, which can be defined by the operator. In the base cabinet, the ACTC isdirectly connected to the COBA.
For input of rack alarms, a 24-Pin spring pressure terminal clamp is used on the ACTC.The ACTC board provides 4-pin connectors for DC output (-48 V) / alarm interface and2-pin connectors for alarm interface only to following units:• Fan units• Smoke sensor• Rack Door Open sensor• Temperature sensor• Lightning Protection Alarm
A30808-X3247-L22-6-7618 41
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
3.16 AC/DC Converter (AC/DC)Up to 6 AC/DC converters (only one Frame) can be equipped in the Service1 Rackwhich provide n+1 redundancy. AC/DC converters work in load sharing, but n AC/DCare able to supply the whole BS-240/241 II .Each AC/DC rectifier has an integrated fan to force airflow through the module forcooling purposes.A local AC/DC supervision and management system has been implemented which isaccessible via RS232 interface and external PC.The AC/DC system has external alarms outputs to be connected to the ACTC.
The AC/DC tasks are:– output supplying all -48V consumers within the BS-240/241 II; input supplying of
230V AC 1 phase system for the world market and 208V AC 2 phase system (208Vphase to phase) for the US market.
– supplying external equipment with -48V.– charging and supervising of different battery backup types with different capacities.– supervising rectifiers, batteries and alarm messaging.– switching off DC outputs (rectifiers as well as battery) in case of under and over
temperature.– hot plug in/out.– operation of two Frames in parallel.
The AC/DC and the backup batteries work as an Uninterruptable Power Supply System(UPS).
The nominal DC output power of one AC/DC converter module is:
1600 W for +50˚C ambient temperature environment (+122˚F).
Two AC/DC converter modules shall be installed into the AC/DC Frame of the
BS-240/241-II Service1 Rack at least (minimum configuration).
Up to six AC/DC Converters may be installed into the AC/DC Frame depending on theeffective DC power consumption required by the BTSplus subsystem.
3.16.1 DC and Battery Controller (DCBCTRL)The DC and Battery Controller is the supervision unit for the AC/DC Converters installedin the Frame AC/DC and for the Batteries charging of this set of AC/DCs.A serial data link (RS-232) is provided for downloading the DCBCTRL set-up data (likethe nominal battery capacity of the connected battery systems).
3.17 Overvoltage Protection and Tracer (OVPT)The OVPT is responsible for lightning protection of the PCM24/PCM30 ports of the Abisinterface and the external synchronization clock input of the BS-240/241 II against overvoltage. Additionally, the OVPT provides interfaces to connect PCM tracers withoutinterruption for monitoring the Abis lines. The OVPT is located outside the EMI shield inorder to terminate possible overvoltages before it enters the EMI protected area insidethe Rack.
The board performs the following tasks:– lightning protection of PCM lines
42 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
– provision to connect external monitoring equipment without interruption. The linesare de-coupled by resistors in order to prevent distortions.
– supporting 75 Ω coax or 100 Ω/120 Ω balanced lines– for 75 Ω coax only a second version of the OVPT is available– provides grounding facility for the external cable shielding– provides stress relief for the external cables
3.18 Abis Connection Module (ABISCON)The Abis Connection module provides the interface between the base cabinet and theperipheral Abis-cables. The Abis Connection module also provides the feature for moni-toring the Abis lines.
The type of Abis Connector depends on the used cable for the Abis interface• symmetrical lines with 100/120 Ohm impedance• coaxial lines 75 Ohm impedance
The ABISCON module can be installed only as alternative to the Over Voltage Protec-tion and Tracer module (OVPT).
3.19 Abis Link Equipment (LE)The Link Equipment acts as front end to provide the Abis interface. Different equipmentcan be used for wire or radio transmission depending on customer requirements. If aLink Equipment is available at the telecommunications site, no additional Link Equip-ment is necessary inside the BTSE. If the BS-240/241 II is installed away from a tele-communications site, the Link Equipment can be installed inside the ServiceRack/Shelter. If radio transmission is required, microwave equipment can be used.Direct connections of the PCM24/30 links are also possible.
3.20 Cover PartsAll unequipped slots in the Frames of a Rack/Shelter must be equipped with CoverParts, to reach a balanced airflow. If the complete Frame is empty, it is not necessary tocover all the empty slots.
3.21 Backup Battery (BATTERY)The BTS-240/241 II can be equipped with Backup Batteries that have to be installed inthe Service Racks/Shelters only. The backup time of each BTS-240/241 II can beincreased by additional batteries installed in the Service2 rack(s)/shelter(s) and/or usingthe feature "Emergency Configuration". When the AC mains breaks down the batterytakes over the supply of the BTESplus. To hold the system in operation mode for anextended time it is necessary to switch to this configuration after a predefined timeinterval. In this operation mode only the TRX configured by the user remains in opera-tion. All the other TRX(s) of the installed CUs are switched off. The core modules andthe optional transmission equipments are supplied with DC voltage until the backupbattery is disconnected from the system load by the Low Voltage Detection Circuit.
iIn the BS-240/241 II system, the Over-Voltage Protection of the Abis Interface is anoptional feature.
A30808-X3247-L22-6-7618 43
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
One frame AC/DC can be connected to two battery systems with two independentconnecting leads. One battery system can consist of up to three battery groups (onegroup can consist of up to four batteries) which are always in the same Rack/Shelter dueto temperature control issues.
Fig. 3.7 Example of Battery Backup Systems Connected to the AC/DC
The maximum DC-Output-Power of one Frame AC/DC is limited to 7800W. Themaximum current out of one battery system is limited to 50A (respectively 2400W at48V). All battery systems connected to frame AC/DC should have the same batterycapacity.
3.22 FanThe Fan Unit is responsible for creating a sufficient airflow in order to cool the inner elec-tronics using all the effects of forced convection cooling.
In order to keep both the acoustic noise and the power consumption of all fans at thelowest level possible, the fan speeds are (independently of each other) temperaturecontrolled via integrated sensors that monitor the critical hotspots to keep them in anacceptable range.
Furthermore, each fan delivers a fan good/fan bad signal that is processed by the COBAboard (routed via ACTC board in case of a Base Rack/Shelter or the ACTC board andCAN Bus in case of an Extension-/Service Rack/Shelter).
Mandatory fan units:
Six fan units shall be installed into
- BS-240-II Base Rack,
- BS-240-II Extension Rack,
- BS-241-II Base Shelter
- BS-241-II Extension Shelter.
Two fan units shall be installed into
Battery 0
Base Frame for AC/DC Converter
DCBCTRL
AC
DC-
AC
DC-
AC
DC-
AC
DC-
AC
DC-
AC
DC-
Battery System 0
DC line
DC line
Battery System 1
Battery 1 Battery 2
Battery 0 Battery 1 Battery 2
Module
Module
Module
Module
Module
Module
44 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
-- BS-240-II Service 1A Rack,
- BS-241-II Service 1A Shelter.
- BS-241-II Service 2 Shelter.
Optional fan units:
Two additional fan units shall be installed into
- BS-240-II Service 1A Rack if more than 6 HU for LE (> 600 W) are provided there.
Two fan units shall be installed into
- BS-240-II Service 2 Rack if any HU for LE is provided there.
Four fan units shall be installed into
- BS-240-II Service 2 Rack if more than 12 HU for LE (> 1 kW) is provided there.
A30808-X3247-L22-6-7618 45
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
3.23 Heater UnitThe operating range of the BS-241 II is from –33˚C to +50˚C ambient temperature.
The task of the heater is to warm up the BTSEplus, if the temperature inside the shelteris below the specified operating temperature range of the integrated modules.
The heater is an optional unit. The utilisation of heater unit depends on the climaticconditions at the BTSE site if low temperature operation is expected.
For ambient temperatures below –5˚C, each Rack needs one heater unit.
If the heater is faulty, the BTSEplus will operate as long as the temperature inside theshelter stays within defined operating range. If the temperature falls below the lowerthreshold of the defined range, all AC/DC converters will be switched off and the BTSE-plus Carriers go down. If the internal temperature rises into the defined operating rangeagain, the system starts automatically with operation.
In case of Shelter:The membrane filter, and its integral frame which is made of a corrosion resistant mate-rial, is fitted to the inside of the door to prevent dust particles or water from being drawnin, and which may accumulate at the exposed exterior. The current design of the filter issuch that an accumulation of particles may reduce the cooling effects but only to a levelwithin the BTS environmental specification.
46 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
4 Antenna Combiners and Receiving Paths
4.1 Methods of CombiningIn order to serve cells with different carrier numbers, certain combinations of combiningmodules are required. These configurations provide the necessary performance in aneffective way.
For the UL (Up Link) path, antenna diversity is always considered. The required splittingfactor only depends on the maximum carrier number per cell without yielding a reason-able technical penality.
With respect to the DL (Down Link), a trade off exists between the number of antennasand the insertion loss for a given carrier number. Increasing the antenna numberdecreases the DL insertion loss introduced by hybrid combining of Carriers to oneantenna port. For high carrier numbers per cell (≥5) filter combining becomes advanta-geous with respect to insertion loss but suffering from incompatibility to synthesizerfrequency hopping.
Nevertheless, for urban sites where the cell sites are usually small a configuration witha DUAMCO 8:2 supports synthesizer frequency hopping and there is no need for addi-tional antennas. Fig. 4.1 the different combining options are shown. The relationshipbetween labels and components is shown in Fig. 2.3.
Fig. 4.1 Overview of Combining Options
2:2
2x
4:2
4x
8:2
8x
TMA
Tower Mounted
2:1
RX
High Power Duplexer
Duplex Combining
Filter Combining
HPDU2:1
TX8x 8x
2x8DUBIAS
and BIAS-T
Amplifier
A30808-X3247-L22-6-7618 47
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
DUAMCO (Duplexer Amplifier Multicoupler)
The DUAMCO x:y modules contain duplex filters in order to combine the transmit andreceive path to one antenna connector. The receive and transmit part of the duplex filter,respectively, provide the substantial part of the receive and transmit band filteringrequired by GSM 05.05, 11.21 and JTC J-STD-007.
The receive path consists of a LNA (Low Noise Amplifier) and a power splitter. The LNAtakes care of a low system noise figure and consists of two branches. In case ofmalfunction of one amplifier, the RX gain of the DUAMCO decreases by about 6 dB. Thepower splitter distributes the received band to the CUs (Carrier Units). A splitting factorof 4 (or 8 in case of DUAMCO 8:2) is implemented in order to feed 4 (8) CUs.
The DUAMCO amplifier has two different operation modes which can be selected bye.g. DIP switches. In the following, mode 1 is called AMCO mode and the second modeis called MUCO mode. In the AMCO mode where no TMA (Tower mounted Amplifier) isused, the DUAMCO gain is around 19 dB. In case a TMA is used, the DUAMCO isconfigured in the MUCO mode. In the MUCO mode, the gain is reduced to about 0 dB.This adjustment is only done once during the installation of the BTSE by the servicepersonal. The selected mode can be read by O&M SW via CAN bus interface.
The transmit path consists of isolators, a hybrid coupler with load (for some modules)and an ASU (Antenna Supervision Unit). The isolators have to protect the PAs (PowerAmplifiers) inside the CUs from each other in order to assure the required intermodula-tion suppression. Two different hybrid couplers (2:1, 4:1) combine up to 4 Carriers to oneantenna. The corresponding not transmitted power is terminated in a load includingcooler. The ASU is responsible for detecting certain reflection factors at the antennaconnector and is connected to the O&M interface.
The O&M interface of the DUAMCO transmits error messages to the BTS core via aslow O&M bus (CAN bus).
The DUAMCOs x:y are named depending on the number x of transmit connectors fedby the CUs and the number y of antenna connectors. The following figures show thedifferent DUAMCOs implemented by a set of equal sub-modules.
The DUAMCOs are implemented for seven different frequency bands: GSM 850,P-GSM 900, GSM 1800 (DUAMCO 2:2 , DUAMCO 4:2 and DUAMCO 8:2); E-GSM 900,R-GSM 900, GSM-RE 900, GSM 1900 ( DUAMCO 2:2 and DUAMCO 4:2). The divisionof the GSM 900 band (39 MHz) in two interleaved sub-bands (25 MHz each, P-GSM andGSM-RE) results from the required filter volume for the whole band.(see Tab. 1.2)
48 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
Fig. 4.2 DUAMCO 2:2
Fig. 4.3 DUAMCO 4:2
Rx Tx
ASU
LNA
RXCA to Rx fromTx
Control
CAN
DC interf.
TMA
DC/DC
TMA
Signall.
Rx Tx
ASU
LNA
RXCAto Rx from
Tx
AMCO
MUCO
AMCO
MUCO
LNALNA
bus
BiasTEE
BiasTEE
Module 0 Module 1
Antenna 0 Antenna 1
Antenna 0
Rx Tx
ASU
LNA
RXCAto Rx
fromTx
Control
CAN busDC interf.
TMA
DC/DC
TMA
Signall.
Rx Tx
LNA
RXCA
to RxfromTx
Antenna 1
Coupler
to/from core
ASU
CouplerAMCO
MUCO
AMCO
MUCO
LNA LNA
BIASTEE
BIASTEE
Module 0 Module 1
A30808-X3247-L22-6-7618 49
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
Fig. 4.4 DUAMCO 8:2
FDUAMCO (Flexible Duplexer Amplifier Multicoupler) / DUAMCO
The FDUAMCO modules contain duplex filters in order to combine the transmit andreceive path to one antenna connector. The receive and transmit part of the duplex filter,respectively, provide the substantial part of the receive and transmit band filteringrequired by GSM 05.05, 11.21 and JTC J-STD-007.
The receive path consists of a LNA (Low Noise Amplifier) and a power splitter. The LNAensures a low system noise figure and consists of two branches. In case of malfunctionof one amplifier, the RX gain of the FDUAMCO decreases by about 6 dB. The powersplitter distributes the received band to the carrier units. A splitting factor of 4 is imple-mented in order to feed up to 4 Carriers. Additionally, the FDUAMCO has a cascadeoutput.
The FDUAMCO amplifier has two different operation modes which can be selected byDIP switches. One mode is called AMCO mode and the other is called MUCO mode. Inthe AMCO mode where no TMA is used, the FDUAMCO gain is around 19 dB. In casea TMA is used, the FDUAMCO is configured in the MUCO mode. In the MUCO mode,the gain is reduced to about 0 dB. The exact gain of the FDUAMCO to compensate thecable losses can be adjusted for this mode with a DIP switch. This adjustment is onlydone once during the installation of the BTSE by the service personal. The selectedmode can be read by O&M software via CAN bus interface.
The transmit path consists of isolators, a hybrid coupler depending on jumper settingand an ASU (Antenna Supervision Unit). The isolators have to protect the PAs (PowerAmplifiers) inside the carrier units from each other in order to assure the required inter-modulation suppression. By usage of a hybrid coupler up to 4 Carriers are combined toone antenna. The corresponding not transmitted power is terminated in a load including
Rx Tx
ASU
LNA
RXCAto Rx
fromTx
Control
CAN busDC interf.
TMA
DC/DC
TMA
Signall.
Rx Tx
LNA
RXCAto Rx
fromTx
Coupler
to/from core
ASU
CouplerAMCO
MUCO
AMCO
MUCO
LNA LNA
BIASTEE
BIASTEE
Module 0 Module 1
Antenna 0 Antenna 1
50 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
cooler. The ASU is responsible for detecting certain reflection factors at the antennaconnector and is connected to the O&M interface.
The O&M interface of the FDUAMCO transmits error messages to the BTS Core viaCAN bus.
FICOM (Filter Combiner)
The filter combiner consists of a band pass filter for filtering the transmit frequency band,the VSWR supervision unit, as well as remotely tunable narrowband filters (TNF) withtheir control logic and the isolators for every TX input.
The low loss power addition is carried out by combining the outputs of TNFs inside theFICOM. These TNFs are remotely tuned to the channel frequency of the correspondingcarrier. The minimum number of inputs to be combined is 2. It is possible to combine amaximum number of 8 inputs by adding 'expansion modules' to the 'base module'.
A TNF is first coarse tuned to the desired channel. If RF power is supplied to the TNF itautomatically performs a fine tuning to ensure the best RF behavior. With this automatictuning process, the drift of the passband filter center frequency is compensated.
Therefore, the filter combiner can only be used with baseband frequency hopping, asretuning of the TNF frequency requires up to 5 seconds. But for a large number ofCarriers (6 or 8), baseband frequency hopping has only a negligible disadvantagecompared to synthesizer frequency hopping.
The FICOM functions are carried out by two different types of modules. These are:– Base module 2:1– Expansion module 2:1
Each type of module is able to combine 2 Carriers. But only the base module has anoutput for the completely combined signal (antenna output with 7/16 connector). Addi-tional there is a test output at every base module. Also, the reporting of the antennaVSWR status is only done by a base module. The different modules are connectedtogether by a special RF connection cable.
Therefore, the number of base modules is equal to the number of cells the FICOM hasto support. The number of expansion modules per cell depends on the total number ofCarriers per cell (2,4,6 or 8).
A FICOM Expansion module 1:1 doesn't exist any more. In case an odd number ofCarriers is recommended in one cell, only one half of the expansion module 2:1 is used.For this application, one TX port remains open.
The FICOMs are implemented for two different frequency bands: GSM-R 900 and GSM1800.
A30808-X3247-L22-6-7618 51
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
Fig. 4.5 FICOM 8:1
DIAMCO (Dual Integrated Amplifier Multicoupler)
The DIAMCO contains two sub-modules with receive filters, low noise amplifiers andpower splitters.
For the uplink direction, the DIAMCO has to be used to filter and distribute the receivedsignals to the Carrier Units. With the FICOM, it is possible to combine 8 frequencies indownlink direction (TX) in one Rack.The receive filters provide the substantial part of thereceive band filtering required by GSM 05.05, 11.21 and JTC J-STD-007.
The LNA takes care of a low system noise figure and consists of two branches. In caseof malfunction of one amplifier the RX gain of the DIAMCO decreases by about 6 dB.The power splitter distributes the received band to the CUs (Carrier Units). A splittingfactor of 8 is implemented in order to feed 8 CUs. Additionally, the DIAMCO has acascade output which is used for Rack Extension.
In addition, the functionality of a PDU (Power Distribution Unit) for two TMAs is inte-grated in the DIAMCO. This is the DC power supply and the alarm supervision of theTMAs. Alarm monitoring is done with a signalling interface between DIAMCO and TMA,modulated onto a IF carrier at 7.86 MHz: This interface is identical to the interfacebetween DUAMCO and TMA.
The DIAMCO RX amplifier has two different operation modes, depending on the exist-ence of TMAs. The first mode is called AMCO mode, the second one is called MUCOmode. In the AMCO mode where no TMA is used, the DIAMCO gain is around 19 dB.In case a TMA is used, the DIAMCO is configured in the MUCO mode. In the MUCOmode, the gain is reduced to about 0 dB. This adjustment is only done once during theinstallation of the BTSE by the service personnel. The selected mode can be read byO&M SW via CAN bus interface.
TNF TNF
ESN
Control
CAN busDC interf.
VS WRsupervision
Antenna
fromTx
fromTx
TNF TNF
ESN
Control
CAN busDC interf.
fromTx
fromTx
TNF TNF
ESN
Control
CAN busDC interf.
fromTx
fromTx
TNF TNF
ESN
Control
CAN busDC interf.
fromTx
fromTx
Base 2:1 Exp 2:1 Exp 2:1 Exp 2:1
52 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
Due to the fact that TMA status information is available for the DIAMCO processor, theDIAMCO itself has to switch the RX mode according to the TMA status. Each TMA canbe switched on or off by a separate switch. This cannot be configured via O&M SW!
For Rack Extension the first DIAMCO works in the AMCO mode and the followingDIAMCO sub-modules in the MUCO mode.
The O&M interface of the DIAMCO transmits error messages to the BTS core only viathe CAN bus.
The DIAMCOs are implemented for two different frequency bands: E-GSM 900 andGSM 1800.
Fig. 4.6 DIAMCO
Antenna 0
Rx
RXCA
to Rx
Control
CAN busDC interf.
TMA
DC/DC
TMA
Signall.
Antenna 1
to/from core
Rx
RXCA
to Rx
LNA
AMCO
MUCO
LNA
LNA
AMCO
MUCO
LNA
BIASTEE
BIASTEE
Module 0 Module 1
A30808-X3247-L22-6-7618 53
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
High Power Duplexer (HPDU2)
The High Power Duplexer has the task of combining the TX and the RX paths into oneantenna, in order to minimize the number of antennas when FICOM is used. The HPDUcontains a duplex filter for the transmit frequency band and for the receive frequencyband, but no Low Noise Amplifier in the RX path. If the TMA is used together with aHPDU, the BIAS-T (DUBIAS) for powering and signalling of the TMA is required. Up totwo HPDU can be integrated on top of the Rack below the cover and also up to twoHPDU can be fit in the gap between the inner side wall and the Frame in the Shelter.For the main RX path, one HPDU per cell is installed. For diversity operation, a secondreceive path has to be installed. In one Base or Extension Rack/Shelter, one or twoHPDUs can be installed and a maximum of 8 Carriers can be connected to one HPDU.
Fig. 4.7 shows the standard configuration for one cell using HPDU, FICOM andDIAMCO for up to 8 Carriers in one Rack.
The HPDUs are implemented for three different frequency bands: P-GSM 900, GSM1800 and GSM-PS 900 (P-GSM shifted to E-GSM).
Fig. 4.7 HPDU
BIAS-T (DUBIAS)
If the TMA is to be used together with a HPDU, a BIAS-T (DUBIAS) for powering andsignalling of the TMA is required.
The DUBIASs are implemented for two different frequency bands: R-GSM 900 andGSM 1800 .
FICOM
TX-Filter
TX-Filter RX-Filter
HPDU
DIAMCO
RX-Filter RX-Filter
0 1 2 7TX
0 1 2 7RX
0 1 2 7RX
54 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
Fig. 4.8 Configuration with HPDU, DUBIAS and TMA
TMA TMA
DUBIAS
HPDU
TX/RX RX
FICOM
CU0 CU1 CU7
DIAMCO
RX0 RX1 RX7
Antenna Antenna
A30808-X3247-L22-6-7618 55
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
Diplexer
The Diplexer gives the possibility to use one Antenna Feeder Cable for both GSM 850with GSM 1900 and GSM 900 with GSM 1800 frequencies. One Diplexer is needed tocombine the 2 different frequencies at the BTSs side and the other one to separate thefrequencies near the antennas. The diplexer offers the possibility to reduce the numberof Antenna Feeder Cables in all cases where GSM 900 and GSM 1800, GSM 1900 orGSM 850 and GSM 1900 Feeder Cables have to be installed in parallel. This is e.g. thecase where an existing GSM 900 network will be extended by a GSM 1800 or GSM 1900network to implement a Dual Band Network.
Fig. 4.9 Configuration with Diplexer (Example)
Antenna Dual Band
900 MHz1800 MHz
Diplexer
DUAMCO 2:2
(1800 MHz)
DUAMCO 2:2
(900 MHz)
Diplexer
f1 f2
f1 + f2
f1 f2
56 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
4.1.1 TX Attenuation of Combiner UnitsGuaranteed combiner TX attenuation: full frequency range, full temperature range.
Typical combiner TX attenuatio: mid band, room temperature.
Type GSM 900 (dB) GSM 1800 (dB)
typical guaranteed typical guaranteed
FICOM 2:1 2.3 2.7 2.5 3.7
FICOM 4:1 2.5 3.2 3.0 4.2
FICOM 6:1 3.0 3.7 3.5 4.8
FICOM 8:1 3.5 4.2 4.0 5.8
Tab. 4.1 Insertion loss of FICOMs
Type GSM 850 (dB) GSM 900/1800/1900 (dB)
typical guaranteed typical guaranteed
FDUAMCO 2:2 1.2 2.4 1.2 2.2
FDUAMCO 4:2 4.3 5.6 4.3 5.4
FDUAMCO 8:2(+COAMCO)
7.8 9.1 7.8 8.9
Tab. 4.2 Insertion loss of FDUAMCOs
Type GSM 850/900/1800/1900 (dB)
typical guaranteed
DUAMCO 2:2 1.2 2.5
DUAMCO 4:2 4.3 5.7
DUAMCO 8:2 7.4 8.9
Tab. 4.3 Insertion loss of DUAMCOs
Type GSM 900 (dB) GSM 1800 (dB)
typical guaranteed typical guaranteed
HPDU 0.4 0.6 0.5 0.75
TMA 0.5 0.8 0.5 0.8
Tab. 4.4 Insertion loss of HPDU and TMA
A30808-X3247-L22-6-7618 57
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
4.1.2DUAMCO - DIAMCO GAIN (RX Path)
DUAMCO - DIAMCO gain
DUAMCO gain GSM 850, GSM,P-GSM,GSM-RE, GSM-PS
GSM 1800, GSM1900
AMCO characteristics
Gain (ANT-RX) 20 dB +/-1.5 dB 22 dB +/-1.5 dB
MUCO characteristics
Gain (ANT-RX) 2 dB +/-1 dB 3 dB +/-1 dB
Attenuator characteristics
Attenuator range 0+6 dB +/-0.5 dB 0+6dB +/-0.5 dB
Step size 1 dB +/-0.3 dB 1 dB +/-0.3 dB
DIAMCO gain E-GSM GSM 1800
AMCO characteristics
Gain (ANT-RX) 20 dB +/-1.5 dB 22 dB +/-1.5 dB
MUCO characteristics
Gain (ANT-RX) 2 dB +/-1 dB 3 dB +/-1 dB
Attenuator characteristics
Attenuator range 0+6 dB +/-0.5 dB 0+6dB +/-0.5 dB
Step size 1 dB +/-0.3 dB 1 dB +/-0.3 dB
Tab. 4.5 Parameters of DUAMCO - DIAMCO
58 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
4.1.3FDUAMCO GAIN (RX Path)
FDUAMCO gain
FDUAMCO gain GSM 850, GSM, P-GSM,GSM-RE,GSM-PS
GSM 1800, GSM 1900
80% BW 100% BW 80% BW 100% BW
AMCO characteristics
Gain (ANT-RX) 20.0 dB +/-1.3 dB 20.0 dB +/-1.5 dB 22.0 dB +/-1.3 dB 22.0 dB +/-1.5 dB
MUCO characteristics
Gain (ANT-RX) 2.0 dB +/-0.8 dB 2.0 dB +/-1 dB 3.0 dB +/-0.8 dB 3.0 dB +/-1 dB
Attenuator characteristics
Attenuator range 0+6 dB +/-0.5 dB 0+6 dB +/-0.5 dB 0+6 dB +/-0.5 dB 0+6 dB +/-0.5 dB
Step size 1 dB +/-0.3 dB 1 dB +/-0.3 dB 1 dB +/-0.3 dB 1 dB +/-0.3 dB
Tab. 4.6 Parameters of FDUAMCO
A30808-X3247-L22-6-7618 59
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
4.1.4 Parameters of Tower Mounted Amplifier (TMA)
E-GSM TMA Characteristic
-25˚C / +45˚C -45˚C / +60˚C
UPLINK
Gain (ANT-COM) 24 dB +/-2 dB 24 dB +/-2.5 dB
Attenuation Failsafe <=4 dB <=4.2 dB
RF input VSWR (COM port) <=1.5 <=1.5
RF input VSWR Failsafe (COM port) <=2.3 <=2.3
DOWNLINK
Max input RF power 50W max GMSK30W RMS, 420 W PEP 8-PSK
Insertion Loss TX Path (COM-ANT) <=0.8 dB <=0.8 dB
RF output VSWR (COM port) <=1.5 <=1.5
RF output VSWR Failsafe (ANT port) <=2.3 <=2.3 B
GENERAL
Consumption <=6 W
Size W x H x D 175 x 282 x 95 mm
Weight <=7 Kg
Supply Voltage Range +12 V +/-8%
Antenna connector 7/16
BTS connector 7/16
Alarm functions alarming via sub-carrier to DUAMCO or DIAMCO
Tab. 4.7 Parameters of 900 MHz Tower Mounted Amplifier
60 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
The TMAs are implemented for four different frequency bands: P-GSM 900, GSM-RE900 (RE: Railway Extension; DUAMCO 2:2 and DUAMCO 4:2), GSM 1800 and GSM1900 (DUAMCO 2:2 and DUAMCO 4:2). The division of the GSM 900 band (39 MHz) intwo interleaved sub-bands (25 MHz each, P-GSM and GSM-RE) results from therequired filter volume for the whole band.(see Tab. 1.2)
GSM 1800 TMA Characteristic
-25˚C / +45˚C -45˚C / +60˚C
UPLINK
Gain (ANT-COM) 25 dB +/-2 dB 25 dB +/-2.5 dB
Attenuation Failsafe <=4 dB <=4.2 dB
RF input VSWR (COM port) <=1.5 <=1.5
RF input VSWR Failsafe (COM port) <=2.3 <=2.3
DOWNLINK
Max input RF power 50W max GMSK30W RMS, 420 W PEP 8-PSK
Insertion Loss TX Path (COM-ANT) <=0.8 dB <=0.8 dB
RF output VSWR (COM port) <=1.5 <=1.5
RF output VSWR Failsafe (ANT port) <=2.3 <=2.3
GENERAL
Consumption <=6 W
Size W x H x D 175 x 282 x 95 mm
Weight <=7 Kg
Supply Voltage Range +12 V +/-8%
Antenna connector 7/16
BTS connector 7/16
Alarm functions alarming via sub-carrier to DUAMCO or DIAMCO
Tab. 4.8 Parameters of 1800 MHz Tower Mounted Amplifier
A30808-X3247-L22-6-7618 61
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
4.1.5 Examples for BTSE ConfigurationsMost frequently used configurations:– 3/3/2 with duplex combining– 8/0/0 with filter and duplex combining– 2/2/2 with duplex combining– FDUAMCO 2:2 and 4:2 configuration– FDUAMCO / COAMCO8 8:2 configuration
Fig. 4.10 Multi-cell (3,3,2): with 3 DUAMCO 4:2
Fig. 4.11 Multi-cell (3,3,2): with 2 DUAMCO 4:2 and 1 DUAMCO 2:2
RX TX RX
DUAMCO 4:2
TX
CU2CU0 CU1
CELL 0
RX TX RX
DUAMCO 4:2
TX
CU6 CU7
CELL 2
RX TX RX
DUAMCO 4:2
TX
CU5CU3 CU4
CELL 1
RX TX RX
DUAMCO 4:2
TX
CU2CU0 CU1
CELL 0
RX TX RX
DUAMCO 2:2
TX
CU6 CU7
CELL 2
RX TX RX
DUAMCO 4:2
TX
CU5CU3 CU4
CELL 1
62 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
Fig. 4.12 Single-cell (8,0,0): with FICOM and DIAMCO
Fig. 4.13 Single-cell (8,0,0): with 2 DUAMCO 4:2
CU4 CU5 CU6 CU7CU2 CU3
FICOMBase
Module
FICOMExpansion
Module
TX
FICOMExpansion
Module
FICOMExpansion
Module
CU0 CU1
RX RX
DIAMCO DIAMCO
RX TX RX
DUAMCO 4:2
TX RX TX RX
DUAMCO 4:2
TX
CU4 CU5 CU6 CU7CU2 CU3CU0 CU1
CELL 0
A30808-X3247-L22-6-7618 63
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
Fig. 4.14 Multi-cell (2,2,2): with 3 DUAMCO 2:2
Fig. 4.15 FDUAMCO Configuration 2:2 or 4:2
RX TX RX
DUAMCO 2:2
TX
CU0 CU1
CELL 0
RX TX RX
DUAMCO 2:2
TX
CU2 CU3
CELL 1
RX TX RX
DUAMCO 2:2
TX
CU4 CU5
CELL 2
64 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
Fig. 4.16 Configuration of FDUAMCO / COAMCO8
A30808-X3247-L22-6-7618 65
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
Fig. 4.17 Single-cell (11...16,0,0): FICOMs, DIAMCOs and HPDUs in 2 Racks
CU4 CU5 CU6 CU7CU2 CU3
FICOMBase
Module
FICOMExpansion
Module
TX
FICOMExpansion
Module
FICOMExpansion
Module
CU0 CU1
RX RX
HPDU
DIAMCO
CU12CU13CU14 CU15CU10CU11
FICOMBase
Module
FICOMExpansion
Module
TX
FICOMExpansion
Module
FICOMExpansion
Module
CU8 CU9
RX RX
DIAMCO DIAMCO
RACK 0
RACK 1
TX - Filter RX - Filter
TX- Filter RX - Filter
HPDU
DIAMCO
66 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
4.2 FCC Issues (for US Market Only)In this chapter you find the maximum output power at the antenna connector of theBTS.These values are only relevant for the US market.
Revised FCC Certification for ECU 850
For ECUs with 869.2 and 893.8 MHz frequencies, in order to fulfil the FCC requirementsin the USA, the maximum transmitting power of the corner frequencies of the GSM 850band (channel numbers 128 and 251, i.e. 869.2 MHz and 893.8 MHz, respectively) isdecreased for all carrier units available for the U.S. market. This feature is realized persoftware.The BTS evaluates the mobile country code (MCC) provided by the BSC via the attribute"cellGlobalIdentity". If the MCC indicates “USA“, the BTS reduces the output power ofthe corner frequencies dependent on the hardware type of the carrier unit. The followingtable represents the maximum RF power output values for GMSK and 8PSK modula-tion.
Revised FCC Certification for ECU 1900
For ECUs with 1930.2 and 1989.8 MHz frequencies, in order to fulfil the FCC require-ments in the USA, the maximum transmitting power of the corner frequencies of theGSM 1900 band (channel numbers 512 and 810, i.e. 1930.2 MHz and 1989.8 MHz,respectively) is decreased for all carrier units available for the U.S. market. This featureis realized per software.The BTS evaluates the mobile country code (MCC) provided by the BSC via the attribute"cellGlobalIdentity". If the MCC indicates “USA“, the BTS reduces the output power ofthe corner frequencies dependent on the hardware type of the carrier unit. The followingtable represents the maximum RF power output values for GMSK and 8PSK modula-tion.
CU Type CarrierFrequency
[MHz]
ChannelNo.
Maximum RFPower Output
GMSK
Maximum RFPower Output
8PSK
ECU850V3(A) 869.2 128 42.3 dBm = 17.0 W 45.6 dBm = 36.3 W
ECU850V3(A) 893.8 251 44.4 dBm = 27.5 W 47.2 dBm = 52.5 W
ECU850HPV2 869.2 128 42.2 dBm = 16.6 W 45.2 dBm = 33.1 W
ECU850HPV2 893.8 251 44.3 dBm = 26.9 W 46.9 dBm = 49.0 W
ECU850V2 869.2 128 40.7 dBm = 11.7 W 43.4 dBm = 21.9 W
ECU850V2 893.8 251 44.4 dBm = 27.5 W 47.2 dBm = 52.5 W
Tab. 4.9 Maximum RF Power Output Values at Antenna Port
A30808-X3247-L22-6-7618 67
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
CU Type CarrierFrequency
[MHz]
ChannelNo.
Maximum RFPower Output
GMSK
Maximum RFPower Output
8PSK
ECUPHPV3(A) 1930.2 512 39.9 dBm = 9.8 W 43.3 dBm = 21.4 W
ECUPHPV3(A) 1989.8 810 42.1 dBm = 16.2 W 45.7 dBm = 37.2 W
ECUPHPV2 1930.2 512 39.3 dBm = 8.5 W 42.2 dBm = 16.6 W
ECUPHPV2 1989.8 810 41.6 dBm = 14.5 W 44.3 dBm = 26.9 W
ECUPV2 1930.2 512 42.1 dBm = 16.2 W 44.7 dBm = 29.5 W
ECUPV2 1989.8 810 44.4 dBm = 27.5 W 47.1 dBm = 51.3 W
Tab. 4.10 Maximum RF Power Output Values at Antenna Port
68 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
5 Power Supply and Battery BackupThe AC/DC is used in the Service Rack/Shelter. It contains one Frame with AC/DC recti-fier modules, one controller board and one LVD relays. Up to 6 rectifier Modules can beinserted in one Frame; thus, the number of modules can be adapted to the actual needfor specific loads.
The AC/DC tasks are:• supplying all -48V consumers within the BTSE out of 230V AC 1 phase system for
the world market and 208V AC 2 phase system (208V phase to phase) for the USmarket
• supplying external equipment with -48V• charging and supervising of different battery types with different capacities of battery
backup systems.• supervising rectifiers, batteries and alarm messaging• switching off DC outputs (rectifiers as well as battery) in case of under and over
temperature• hot plug in/out
The AC/DC and the backup batteries work as an Uninterruptable Power Supply System(UPS).
The AC/DC system consists of:• Frame with AC distribution, DC Distribution, EMI-filter, signal distribution between
rectifiers and controller board via backplane• controller board with battery supervision, rectifier supervision, alarm interface.• up to 6 rectifier modules per Frame each 1560W -48VDC (N+1 redundancy to
achieve 7800W+1560W).• One LVD-Relays per AC/DC Frame
The Backup Battery guarantees continuous operation for a certain time in case of apower main breakdown or AC/DC failure. Four types of Backup Battery with nominalcapacities of 85Ah, 92Ah and 100Ah are available.
The capacity of the Backup Battery can be increased further by having additionalbatteries in separate Service Racks / Shelters.
Note: The Battery Backup Time can also be extended using the feature emergencyconfiguration.
5.1 Support of Emergency Operation for 3rd Party BBUSystemIn the BS-240/241 II implementation the switch into emergency configuration (due to abattery discharge alarm) is triggered by an "ALARM STATUS" CAN bus message thathas been received from the CAN node located in the Service 1A cabinet.
A special setting of the attribute "associatedString" in the command "CREATEENVABTSE" for the corresponding site input allows the operator to indicate that thesupport of emergency configuration is required for the 3rd party battery backup unitsystem.
A30808-X3247-L22-6-7618 69
InformationBase Station System
Technical Description (TED:BSS)BS-240/241 II
6 AbbreviationsACP AC Panel
ACTC Alarm Collection Terminal Connection module
ACTM Alarm Collection Terminal for Master Rack
ACTP Alarm Collection Terminal for Slave Rack
AMCO Amplifier Multicoupler
AMCO Amplifier Multicoupler (mode)
AMR Adaptive Multi Rate Codec
ASIC Application Specific Integrated Circuit
ASU Antenna Supervision Unit
COAMCO8 Co-Duplex and Multicoupler Extension
COBA Core Basis
COSA Core Satellite
CU Carrier Unit
DIAMCO Diversity Amplifier Multicoupler
DL Downlink
DUAMCO Duplex Amplifier Multicoupler
ECU EDGE Carrier Unit
EDGE Enhanced Data Rates for GSM Evolution
EFR Enhanced Full-Rate
FDUAMCO Flexible Duplexer Amplifier Multicoupler
FICOM Filter Combiner
FR Full-Rate
GPRS General Packet Radio Services
GSMK Gaussian Minimum Shift Keying
HDLC High Level Data Link Control
HPDU High Power Duplexer Unit
HR Half-Rate
HSCSD High Speed Circuit Switched Data
LE Link Equipment
LMT Local Maintenance Terminal
LNA Low Noise Amplifier
LVD Low Voltage Detect
MUCO Multicoupler
MUCO Multicoupler (mode)
NTC Negative Thermal Coefficient
OMT Operation and Maintenance Terminal
OVPT Overvoltage Protection and Tracer
PCM Pulse Code Modulation
PDU Power Distribution Unit
PID Product Identification Data
70 A30808-X3247-L22-6-7618
Technical Description (TED:BSS)BS-240/241 II
InformationBase Station System
RF Radio Frequency
SELIC Serial Link Interface Controller (ASIC)
TMA Tower Mounted Amplifier
TNF Tunable Narrowband Filter
TRAU Transcoding and Rate Adaption Unit
TRX Transceiver (Transmitter + Receiver)
UL Uplink
UPS Uninterruptable Power Supply System