R CALL 1-800-999-3600 THI RD ANGLE PROJ ECTI ON DI MENSI ONS I N MI LLI METRES " ALL DI MENSI ONS AND DESI GN CRI TERI A SUBJ ECT TO CHANGE WI THOUT NOTI CE. " PAGE 1OF 4 (DI MENSI ONS I N I NCHES ) L771528 FI LE NO. 177 - 528 REV. 0 PLAN VIEW 0 0 FRONT VIEW 0 0 0 0 0 SIDE VIEW 0 0 0 0 0 0 0 0 13 (") 13 (") 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1673 ( 64 " ) 0 0 0 0 0 0 0 HEIGHT DEPTH DEPTH HEIGHT DEPTH HEIGHT DEPTH HEIGHT A B C D 0 645 (25") 619 (24") 645 (25") 717 ( 28 " ) 645 (25") A B C D E F G H I OPTIONAL CONSUMER BAR CODE SCANNER (SEE "CAUTION" LABEL) 0 0 0 0 717 (28") 175 (6") 329 (12") 213 (8") 0 0 0 0 0 38 ( 1 " ) 79 ( 3 " ) 25 ( 1 " ) 1089 ( 42 " ) 79 ( 3 " ) 782 ( 30 " ) 866 ( 34 " ) 1648 ( 64 " ) 1670 ( 65 " ) 471 (18") 367 (14") 38 (1") 876 (34") POWER CORD LENGTH 2210mm (87") FROM SIDE OF UNIT 272 (10") BULK CASH RECYCLING MODULE OPENING 1159 (45") 251 (9") CONSUMER KEYPAD 1137 (44") 98 (3") HEADPHONE JACK 1123 (44") 32 (1") TOP FUNCTION KEY HEIGHT DEPTH DEPTH HEIGHT DEPTH HEIGHT DEPTH HEIGHT 1374 (54") 175 (9") 1222 (48") 243 (9") 1183 (46") 1196 (47") RECEIPT PRINTER E F G H HEADPHONE JACK MOTORIZED CARD READER DIP CARD READER DEPTH HEIGHT 938 (36") I CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR ADDITIONAL DETAILS AND INFORMATION. PLEASE SEE PLANNING AND SITE PREPARATION GUIDE TP-820911-001 PD 5761. BAR CODE SCANNER SHELF HEIGHT - FROM BOTTOM OF SAFE DEPTH - FROM FRONT EDGE OF BEZEL 188 (7") 136 (5") 30 (1") AIR INTAKE AIR EXHAUST R 946 (37") 229 (9") OPTEVA 328 BULK CASH RECYCLING TERMINAL FRONT LOAD WITH 40mm ( 1 ") SAFE 946 ( 37 " ) 229 ( 9 " ) 1343 (52") 361 ( 14 " )

Upload: others

Post on 27-Feb-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: A B C D E F G H I service terminals - ATMs...4 6 (3 7 ‡ ") 2 2 9 ... 12 usc 882, and meets the attack test per ul 291-15. the safe door has a positive relocking feature. the safe

R

CALL 1-800-999-3600

THIR

D

AN

GL

E

PR

OJ

EC

TIO

N

DIM

EN

SIO

NS IN

MIL

LIM

ET

RES

"AL

L

DIM

EN

SIO

NS

AN

D

DESIG

N

CRIT

ERIA

SU

BJ

EC

T

TO

CH

AN

GE

WIT

HO

UT

NO

TIC

E."

PA

GE 1 O

F 4

( DIM

EN

SIO

NS IN IN

CH

ES )

L771528

FIL

E

NO. 177-528

RE

V. 0

PLAN VIEW

0

0

FRONT VIEW

0

0

0 0

0

SIDE VIEW

0

0

000 00 0

13 (�") 13 (�")

0

00

0

0 0

0 00

0

00

0

016

73 (6

4�

")

0

0

000

0 0

HEIGHT DEPTHDEPTHHEIGHTDEPTHHEIGHTDEPTHHEIGHT

A B C D

0

645 (25�")

619 (24�")

645 (25�")

717 (2

8�

")

645 (25�")

A

B

C

D

E

F

G

H

I

OPTIONAL CONSUMER

BAR CODE SCANNER

(SEE "CAUTION" LABEL)

0000

717 (28�")

175

(6�")

329 (12�")213 (8�")

0

0

0

0

0

38 (1�

")

79 (3�

")

25 (1")

1089 (4

2�")

79 (3�

")

782 (3

0�

")866 (3

4�

")

1648 (6

4�")

1670 (6

5�

")

471 (18�")367 (14�")

38 (1�")

876 (34�")

POWER CORD LENGTH

2210mm (87") FROM

SIDE OF UNIT

272

(10�")

BULK

CASH

RECYCLING

MODULE

OPENING

1159

(45�")251

(9�")

CONSUMER

KEYPAD

1137

(44�")

98

(3�")

HEADPHONE

JACK

1123

(44�")

32

(1�")

TOP

FUNCTION

KEY

HEIGHT DEPTHDEPTHHEIGHTDEPTHHEIGHTDEPTHHEIGHT

1374

(54�")175

(9�")

1222

(48�")243

(9�")

1183

(46�")

1196

(47�")

RECEIPT

PRINTERE F G H

HEADPHONE

JACK

MOTORIZED

CARD

READER

DIP

CARD

READER

DEPTHHEIGHT

938

(36�")

I

CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR ADDITIONAL

DETAILS AND INFORMATION. PLEASE SEE PLANNING AND SITE PREPARATION

GUIDE TP-820911-001 PD 5761.

BAR CODE

SCANNER

SHELF

HEIGHT - FROM BOTTOM OF SAFE

DEPTH - FROM FRONT EDGE OF BEZEL

188

(7�")

136

(5�")

30

(1�")

AIR INTAKE

AIR EXHAUST

R

946 (37�")

229 (9")

OPTEVA 328 BULK CASH RECYCLING TERMINAL

FRONT LOAD

WITH 40mm ( 1 �") SAFE

946 (3

7�

")

229 (9

")

1343

(52�")

361 (1

4�

")

Page 2: A B C D E F G H I service terminals - ATMs...4 6 (3 7 ‡ ") 2 2 9 ... 12 usc 882, and meets the attack test per ul 291-15. the safe door has a positive relocking feature. the safe

THIR

D

AN

GL

E

PR

OJ

EC

TIO

N

DIM

EN

SIO

NS IN

MIL

LIM

ET

RES

"AL

L

DIM

EN

SIO

NS

AN

D

DESIG

N

CRIT

ERIA

SU

BJ

EC

T

TO

CH

AN

GE

WIT

HO

UT

NO

TIC

E."

PA

GE 2

OF 4

( DIM

EN

SIO

NS IN IN

CH

ES )

FIL

E

NO. 177-528

RE

V. 0

BACK VIEW SIDE VIEW

5

3

1

1

2

4

4

PROVIDE FLAT COVER WITH TAMPER SWITCH.

1

2

3

4

5

mm

mm mm

mm

mm mm

mm mm

mm

mm

mm

E.C. TO SUPPLY COMPATIBLE RECEPTACLE FOR COUNTRY SPECIFIC PLUG-IN

NOTE:

ALARM PROTECTION

PHYSICAL SECURITY

POWER REQUIREMENTS

200-240 VAC (+/-10%) 50Hz (+/-1%) SINGLE PHASE

100-127 VAC (+6%,-10%) 50Hz (+/-1%) SINGLE PHASE

100-127 VAC (+6%,-10%) 60Hz (+/-1%) SINGLE PHASE

200-240 VAC (+/-10%) 60Hz (+/-1%) SINGLE PHASE

RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN CONDUITS. UNLIKE POWER AND

POWER OF ELECTRICAL RUN

TYPE OF ELECTRICAL RUN

UNSHIELDED POWER LINE OR ELECTRICAL EQUIPMENT

LIGHTING CABLE, SIGNAL CABLES HAVE SMALL CONDUCTORS AND LIGHT INSULATION AND WILL NOT

BELOW 2 KVA 2-5 KVA ABOVE 5 KVA

THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS OF THE SIGNAL CABLE RUN

WITH RESPECT TO OTHER POWER AND ELECTRICAL EQUIPMENT CABLE RUN.

127mm (5") 127mm (5") 127mm (5")

305mm (12")

305mm (12")

610mm (2’-0")

64mm (2�") 152mm (6")

152mm (6")76mm (3")30mm (1�")

127mm (5")

FLUORESCENT, NEON OR INCANDESCENT

LIGHTING FIXTURES

POWER LINES IN GROUNDED CONDUIT WITH SIGNAL

CABLES IN GROUNDED CONDUIT

UNSHIELDED POWER LINES OR ELECTRICAL EQUIPMENT

WITH SIGNAL CABLES ENCLOSED IN GROUNDED CONDUIT

CONDUIT AND JUNCTION BOX

REQUIREMENTS

E.C. TO RUN 19 (�") LIQUID TIGHT FLEX METAL CONDUIT OR 19 (�") RIGID

CONDUIT FROM JUNCTION BOX TO CABLE CONNECTING PLATE.

BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR

NEW CONSTRUCTION OR BOXES CAN BE SURFACE MOUNTED

WITH EXPOSED CONDUIT FOR EXISTING CONSTRUCTION.

THE UL-LISTED SAFE IS EQUIPPED WITH A BASIC ALARM SENSOR PACKAGE. THE

BASIC PACKAGE INCLUDES A SAFE DOOR OPEN SWITCH, ALARM SHUNTING SWITCH,

AND RATE-OF-RISE HEAT SENSOR.

THE SECURITY SAFE MEETS THE BANK PROTECTION ACT 82 STAT 295,

12 USC 882, AND MEETS THE ATTACK TEST PER UL 291-15. THE SAFE DOOR

HAS A POSITIVE RELOCKING FEATURE. THE SAFE DOOR IS CONTROLLED BY A

GROUP 2 COMBINATION LOCK WITH OR WITHOUT KEYLOCKING DIAL CAPABILITY

OR OPTIONAL ELECTRONIC LOCK.

25 ( 1") METAL CONDUIT FROM ALARM CONTROL CABINET JUNCTION BOX TO

102 (4") SQ. X 54 (2�") DP. JUNCTION BOX ( ALL BY E.C. ) DIEBOLD TO

100-127 VAC (+6%, -10%) SERVICE, DISCONNECT AT 20 AMPERES

200-240 VAC (~10%) SERVICE, DISCONNECT AT 10 AMPERES

WITHSTAND AS MUCH STRAIN IN INSTALLATION.

0

WHEN "SECUROMATIC" AFTER HOUR DEPOSITORY IS TO BE CONNECTED

TO CASH DISPENSER, E.C. TO RUN 19 (�") METAL CONDUIT FROM 102

(4") SQ. X 54 (2�") DP. JUNCTION BOX TO AFTER HOUR DEPOSITORY.

POWER TO THE CASH DISPENSER MUST BE PROTECTED BY A SAFETY QUICK-

DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A CIRCUIT BREAKER AT

THE ELECTRICAL SERVICE PANEL. THE QUICK-DISCONNECT DEVICE (OR CIRCUIT

BREAKER) MUST TURN OFF THE LINE VOLTAGE AT THE FOLLOWING AMPERAGE.

POWER USAGE

LASER RADIATIONDO NOT STARE INTO BEAM

DIODE LASER1 mW MAX OUTPUT at 635-670 nm

CLASS II LASER PRODUCT

Complies with 21 CFR 1040.10 and 1040.11

Certified in accordance with EIC 60825-1

CAUTION LABEL

SIGNAL CABLE RUN CONSTRAINTS

JUNCTION BOXES MUST BE LOCATED WITHIN 2490mm (98") OF CONNECTING

PLATE. ( LENGTH OF ELECTRICAL POWER CABLE PROVIDED WITH UNIT).

LOCATE IN AN EASILY ACCESSIBLE AREA.

SIGNAL CABLE INSTALLATION CONSTRAINTS

(ALL BY E.C.) (SEE POWER REQUIREMENTS).

0 00 0

00

00

00

0 0 0 0

00

00

00

0

0 00

181

(7�")

325 (12�") 210 (8�")

38 (1�

")79 (3�

")

302 (1

1�")

40 (1�

")

105

(4�

")

79 (3�

")

921 (3

6�

")

79 (3�

")79 (3�

")53 (2�

")

514 (2

0�

")

432 (17") 107

(4�")

107

(4�")

278 (11")140

(5�")

AIR INTAKE

AIR INTAKE

AIR EXHAUST

AIR EXHAUST

THE TERMINAL REQUIRES A SINGLE-PHASE, THREE-WIRE UNSWITCHED POWER

RECEPTACLE. WIRING TO THE RECEPTACLE MUST INCLUDE A THIRD-WIRE EARTH GROUND

(CONDUIT GROUND IS NOT ACCEPTABLE). THE CASH DISPENSER WILL PROVIDE A POWER

CORD WITH A COUNTRY SPECIFIC POWER PLUG. THE POWER SUPPLIED MUST BE AS

SPECIFIED BELOW.

THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY WILL PROVIDE

POWER CONDITIONING TO PREVENT THE TERMINAL FROM MALFUNCTIONING DUE TO

SHORT-TERM AC POWER FLUCTUATIONS AS OUTLINED IN EN6100-4-1 1.

19 (�") METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY TO 102 (4") SQ.

X 54 (2�") DP. JUNCTION BOX WITH RECEPTACLE WITHIN 2210mm (87") OF

SIDE CONNECTING PLATE. BOTTOM CONNECTION MUST BE COMPENSATED ACCORDINGLY

CONNECTOR SUPPLIED WITH UNIT. POWER CORD LENGTH 2210mm (87")

FROM SIDE OF UNIT.

1003 (3

9�

")

WEIGHT OF UNIT

SAFE LOCATION

OPERATING ENVIRONMENT

HEAT OUTPUT

MACHINE STATUS

IDLE (NO TRANSACTION)

1

1

1

10 C TO 38 C (50 F TO 100 F)

RELATIVE HUMIDITY ( NON-CONDENSING )

20 TO 80% AT 32 C (90 F),

20 TO 55% AT 38 C ( 100 F)

CONFIGURATION

CONFIGURATION

TRANSACTION (DISPENSE

IN PROGRESS)

944 kg ( 2,080 LBS.)

300 WATTS

550 WATTS

P4 PROCESSOR, SUNLIGHT VIEWABLE COLOR LCD, CONSUMER DISPLAY,

MOTORIZED CARD READER, JOURNAL PRINTER, RECEIPT PRINTER, UPS,

AND BULD CASH RECYCLING MODULE.

1,878 BTU/HR DISPENSING

1,024 BTU/HR IDLE

Page 3: A B C D E F G H I service terminals - ATMs...4 6 (3 7 ‡ ") 2 2 9 ... 12 usc 882, and meets the attack test per ul 291-15. the safe door has a positive relocking feature. the safe

"AL

L

DIM

EN

SIO

NS

AN

D

DESIG

N

CRIT

ERIA

SU

BJ

EC

T

TO

CH

AN

GE

WIT

HO

UT

NO

TIC

E."

THIR

D

AN

GL

E

PR

OJ

EC

TIO

N

DIM

EN

SIO

NS IN

MIL

LIM

ET

RES

R

CALL 1-800-999-3600

PA

GE 3

OF 4

( DIM

EN

SIO

NS IN IN

CH

ES )

FIL

E

NO. 177-528

RE

V. 0

MINIMUM SERVICE AREA

RECOMMENDED SERVICE AREA

ALL ELECTRICAL AND DATA CABLES

MUST ENTER UNIT IN THIS AREA

0

0

PLAN VIEW( MINIMUM SERVICE AREA )

( MINIMUM SERVICE AREA )

00

00

0 00

0

00

SIDE VIEW

0

0

0

0

INSTALLATION/SERVICE AREA

DIMENSION SHOULD ALLOW FOR A

PERSON STANDING DURING INSTALLATION

AND SERVICING OF UNIT.

VA

RIE

S

VA

RIE

S

R

51

(2")

0

00

00 0 645 (25�")

75 (3")

248

(9�")

1248 (49�")

152

(6")

0

0 00

0

0

0

415 (1

6�

")

51 (2

")

767 (3

0�

")

0

1275 (5

0�

")

2042 (8

0�")

0

0

PLAN VIEW

51

(2")

0

00

00 0 645 (25�")

1349 (53�")

152

(6")

0

0 00

0

0

0

415 (1

6�

")

51 (2

")

767 (3

0�

")

0

1501 (5

9�

")

2268 (8

9�

")

NOTE:

SHOWN IS THE MINIMUM/RECOMMENDED AREA REQUIRED FOR INSTALLATION AND

SERVICE. DIMENSIONS SHOWN MAY BE INCREASED WHEREVER POSSIBLE TO

IMPROVE INSTALLATION AND SERVICE ACCESS. USE OF ANY AREA LESS THAN THE

RECOMMENDED AREA MAY RESULT IN AN INCREASE IN INSTALLATION AND SERVICE

TIME. CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR SPECIAL

BUILDING CONDITIONS.

245

(9�")

213

(8�")

2042 (80�") MINIMUM

1275 (50�") MINIMUM

51 (2")

716 (28�")

38 (1�

")

1686 (6

6�")

OPTEVA 328 BULK CASH RECYCLING TERMINAL

FRONT LOAD

WITH 40mm ( 1�") SAFE

248

(9�")

1648 (6

4�")

279

(11")

( RECOMMENDED SERVICE AREA )

Page 4: A B C D E F G H I service terminals - ATMs...4 6 (3 7 ‡ ") 2 2 9 ... 12 usc 882, and meets the attack test per ul 291-15. the safe door has a positive relocking feature. the safe

"AL

L

DIM

EN

SIO

NS

AN

D

DESIG

N

CRIT

ERIA

SU

BJ

EC

T

TO

CH

AN

GE

WIT

HO

UT

NO

TIC

E."

THIR

D

AN

GL

E

PR

OJ

EC

TIO

N

DIM

EN

SIO

NS IN

MIL

LIM

ET

RES

PA

GE 4

OF 4

( DIM

EN

SIO

NS IN IN

CH

ES )

FIL

E

NO. 177-528

RE

V. 0

0

PLAN VIEW(ADJACENT UNITS)

(MINIMUM SERVICE AREA)

00 645 (25�") 305 (12")0 0 0 0 0 0645 (25�") 305 (12") 645 (25�")

76 (3")

0

279 (11")

0 0 0

0

0570 (22�") 949 (37�") 949 (37�") 678 (26�")

03146 (123�") MINIMUM

0

152

(6")

0

00

0

0

415 (1

6�

")

51 (2

")

767 (3

0�

")

0

1275 (5

0�

")

0

0

2042 (8

0�")

0 0

51

(2")

248

(9�")

51

(2")

51

(2")

3146 (123�") MINIMUM

NOTES:

2.

POWER CABLE PLATE

29 ( 1 �") DIA. HOLE FOR

ALARM CABLES (SIDE ENTRY)

OPENING FOR POWER CORD

AND DATA CABLES

(SIDE ENTRY)

PLAN/SECTION

1 2

00 0 0 0

0

1 1

1 12

0000

0

00000

00

00 0 0

619 (24�") SAFE

480 (18�")

70 (2�") 70 (2�")

472 (1

8�

")

38 (1�

")

370 (1

4�

")

693 (2

7�

")

80 (3�

")106 (4�

")

876 (3

4�

") S

AF

E

83 (3�")83 (3�")

240 (9�") 240 (9�")

(1) 65mm (2�") DIA. RECESS

18mm (�") RECESS DEPTH

22mm (�") DIA. THROUGH-HOLE

(4) 45mm (1�") DIA. RECESS

18mm (�") RECESS DEPTH

22mm (�") DIA. THROUGH-HOLE

ELECTRICAL AND DATA CABLING ENTERS THE TERMINAL THROUGH A CABLE ENTRY

OPENING ON THE SIDE OF THE SAFE. CABLES ENTERING THE TERMINAL PASS THROUGH

THE POWER CABLE PLATE WHICH IS ATTACHED TO THE INSIDE WALL OF THE SAFE OVER

THE CABLE ENTRY OPENING. THE CABLE ENTRY OPENING IS ON THE RIGHT SIDE OF THE

SAFE AS VIEWED FROM THE FRONT OF THE TERMINAL.

1.FOR ADDED SECURITY, IT IS RECOMMENDED THAT THE SAFE BE SECURED TO THE

FLOOR WITH ANCHOR BOLTS (M16 (�") RECOMMENDED - NOT SUPPLIED WITH THE

UNIT). IF THE BOTTOM OF THE SAFE IS NOT FLAT ON THE FLOOR, THE AREA UNDER

THE SAFE MOUNTING HOLES MUST BE FILLED IN FOR ADDITIONAL SUPPORT. A

CONCRETE OR MASONRY FLOOR AT LEAST 152mm (6") THICK IS RECOMMENDED.

MOUNTING HOLES ARE SHOWN IN PLAN/SECTION VIEW FOR SIZE AND LOCATIONS.

RECOMMENDED ANCHOR BOLT SIZE IS FOR REFERENCE ONLY AND THERE MAY BE

REQUIRED INSTITUTION OR COUNTRY SPECIFIC SECURITY NEEDS.