    SH NPI BIWEEKLY REPORT 1 (4)

    Prepared (also subject responsible if other) No.

    201108

    Approved Checked Date Rev Reference

    2011-08-11 A

    1.1.1 D68E01A Hight drop rate deal

    Description of the phenomenon: Observed from the statistics,cell D68E01A with high TCHdrop times recently,TCH drop times is more then fifty times at busy hour,drop rate isnear 10%, Cell d68e01a become worst cell more then eight times for one day, This hasseriously affected the performance of the BSC.

    Analysis:From STS analysis ,almost all the TCH drop calls due to sudden lost.Weinitiallysuspectedhardware devicesfailures, butfound nowarningon theOSS system, and replacedmost of the hardwarebase stationequipment, dropped callsproblem remainsunresolved.

    AndresidentialD68E01Acover the same areaofhighresidentialD68354Aalsoremain highrate ofdropped calls and the mainreason fordropped calls is also suddenly droped.droppedcallsduring the daysessionfocused onworking hours, dropped calls, and wedeterminetheinitialdevice-independent, D68E01A statisticalindicators are as follows:

    TIME CELL

    TCHdroptime

    s

    TCHTraffic

    TCHdroprate

    Sudden lostdroptimes

    Sudden lostdrop /Totaldrop times

    2011/8/2 09:00:00D68E01A

    7 8.66 1.11% 7 100.00%

    2011/8/2 10:00:00D68E01A

    14 11.79 1.78% 14 100.00%

    2011/8/2 11:00:00D68E01A

    24 15.01 2.47% 24 100.00%

    2011/8/2 12:00:00D68E01A

    2 8.29 0.41% 2 100.00%

    2011/8/2 13:00:00D68E01A

    22 7.28 4.42% 22 100.00%

    2011/8/2 14:00:00D68E01A

    80 7.97 12.36% 79 98.75%

    2011/8/2 15:00:00D68E01A

    102 9.28 14.96% 101 99.02%

    2011/8/2 16:00:00D68E0

    1A81 10.38 11.46% 76 93.83%

    2011/8/2 17:00:00D68E01A

    69 7.95 12.61% 69 100.00%

    2011/8/2 18:00:00D68E01A

    0 0.14 0.00% 0 0.00%

    2011/8/2 19:00:00D68E01A

    0 2.07 0.00% 0 0.00%

    2011/8/2 20:00:00D68E01A

    2 19.1 0.18% 0 0.00%

    2011/8/2 21:00:00D68E01A

    2 21.21 0.21% 0 0.00%

    CQT test on site Not find problems, Downlink signal level and downlink quality is good.MRR Statistics found that up-110dBm signal level ratio of more, MRR diagram is as follows

  • 8/3/2019 A Case for Tch Drop Analysis

    2/4

    SH NPI BIWEEKLY REPORT 2 (4)

    Prepared (also subject responsible if other) No.

    201108

    Approved Checked Date Rev Reference

    2011-08-11 A

    Figure1UP and down signal distribution

    CTR analysis found that the main cause of dropped calls is the measurement report(Measure Report) lost and dropped calls T200 timeout:

    Time CseCd3TA

    RxLSbUL

    RxQSbUL

    RxLSbDL

    RxQSbDL

    11:01:58

    Too many measurement generations missing1 -110.5 7 -77.5 4

    11:03:55

    T200 expired (N200+1) times~ abnormalrelease 1 -110.5 7 -79.5 0

    11:06:2

    7 Too many measurement generations missing 2 -110.5 7 -69.5 011:16:5

    9Too many measurement generations missing

    2 -110.5 7 -80.5 411:16:5

    0T200 expired (N200+1) times~ abnormal

    release 2 -110.5 7 -79.5 011:16:4

    3T200 expired (N200+1) times~ abnormal

    release 1 -110.5 7 -79.5 411:18:0

    0Too many measurement generations missing

    - -110.5 7 - -11:18:1

    2Too many measurement generations missing

    - -110.5 7 - -11:21:3

    8T200 expired (N200+1) times~ abnormal

    release 2 -110.5 7 -82.5 511:23:2

    0 Too many measurement generations missing 2 -110.5 7 -81.5 011:27:0

    2Too many measurement generations missing

    2 -110.5 7 -78.5 411:40:5

    3Too many measurement generations missing

    2 -110.5 7 -68.5 011:47:3

    5T200 expired (N200+1) times~ abnormal

    release 1 -110.5 7 -79.5 7

  • 8/3/2019 A Case for Tch Drop Analysis

    3/4

    SH NPI BIWEEKLY REPORT 3 (4)

    Prepared (also subject responsible if other) No.

    201108

    Approved Checked Date Rev Reference

    2011-08-11 A

    11:50:4

    1

    T200 expired (N200+1) times~ abnormal

    release 2 -110.5 7 -74.5 611:53:0

    6T200 expired (N200+1) times~ abnormal

    release 2 -110.5 7 -74.5 011:54:0

    8Too many measurement generations missing

    2 -110.5 7 -72.5 0

    Table 2D68E01A CTR dropped calls reanson statistics for a period of time

    2D68E01A DE- _1 CTR

    Through the CTR analysis, the down up signal and quality are good before call drop. then

    the signal suddenly interrupted ,after a timeout until RLT, BSC release the connection,recorded as a sudden dropped calls. If it is not covered by the elevator or into the tunnelsignal should be decreased gradually rather than suddenly interrupted.For traffic restrictions on D68E01A, dropped calls transferred to the same to the district:G68E29A, two residential weekends dropped calls while indicators are normal, ruled out ahardware problem high dropped calls:

    TIME CELLTCHtraffic

    TCHdroptimes

    sudden los

    CELLTCHtraffic

    TCHdroptime

    s

    sudden los

    2011/8/2 11:00:00D68E01A 15.01 24 24

    G68E29A 8.04 0 0

    2011/8/2 12:00:00D68E01A

    8.29 2 2G68E29A

    5.83 2 2

    2011/8/2 13:00:00D68E01A

    7.28 22 22G68E29A

    4.47 1 1

    2011/8/2 14:00:00 D68E0 7.97 80 79 G68E2 6.06 0 0

  • 8/3/2019 A Case for Tch Drop Analysis

    4/4

    SH NPI BIWEEKLY REPORT 4 (4)

    Prepared (also subject responsible if other) No.

    201108

    Approved Checked Date Rev Reference

    2011-08-11 A

    1A 9A

    2011/8/2 15:00:00 D68E01A

    9.28 102 101 G68E29A

    7.98 3 3

    2011/8/2 16:00:00D68E01A

    10.38 81 76G68E29A

    6.76 2 2

    2011/8/2 17:00:00D68E01A

    7.95 69 69G68E29A

    11.82 1 1

    2011/8/2 18:00:00D68E01A

    0.14 0 0G68E29A

    17.12 114 112

    3D68E01A DE-_1GE-_1

    Dropped calls caused by the transfer of traffic restrictions and comprehensive analysis to

    the CTR, we suspected group call equipment problems or mobile terminal stores, mobilephone chip makers abnormal test (Call directly unplug the power) lead to high droppedcalls. After signaling track, we find D68E01A event of dropped calls are almost 10086.According to statistics IMEI, found that more than one terminal replacing the number thatdial 10086 appear constantly dropped calls. Specific statistics are as follows

    D68E01A signaling device to track a call drop event

    Solution: existence of unusual call in the cell, further investigation can go base on the tracked number