a compact granular bed filter for igcc hot gas clean...
TRANSCRIPT
![Page 1: A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN …tu-freiberg.de/sites/default/files/media/professur... · A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN-UP. 4th International](https://reader031.vdocument.in/reader031/viewer/2022011813/5e369dac97a1747eb050b87f/html5/thumbnails/1.jpg)
1
A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN-UP
4th International Freiberg Conference on IGCC & XtL Technologies
May 4th,
2010
Kavitha
Pathmanathan
![Page 2: A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN …tu-freiberg.de/sites/default/files/media/professur... · A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN-UP. 4th International](https://reader031.vdocument.in/reader031/viewer/2022011813/5e369dac97a1747eb050b87f/html5/thumbnails/2.jpg)
2
Presentation Outline•
Motivation
•
Objective•
Introduction-
Working Principle of Panel Bed Filter (PBF)
-
Filtration Mode-
“Puff-back”
Mode
-
New Filter Design
•
Experiment-
Operating Parameters
-
Setup
•
Results and Discussion•
Conclusion
•
Further Work
![Page 3: A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN …tu-freiberg.de/sites/default/files/media/professur... · A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN-UP. 4th International](https://reader031.vdocument.in/reader031/viewer/2022011813/5e369dac97a1747eb050b87f/html5/thumbnails/3.jpg)
3
Motivation
•
To develop a reliable high temperature gas cleaning unit
WHY
high temperature?
•
Efficient conversion of fuel to energy in power plants•
Protection of downstream process equipments
•
Environmental regulations
![Page 4: A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN …tu-freiberg.de/sites/default/files/media/professur... · A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN-UP. 4th International](https://reader031.vdocument.in/reader031/viewer/2022011813/5e369dac97a1747eb050b87f/html5/thumbnails/4.jpg)
4
ObjectiveTo build and test a new Panel Bed Filter design
Improvement aims reducing: 1. Number of gas-entry surfaces per unit module2. Number of modules per unit filter3. Filter footprint4. Initial and residual pressure drop
![Page 5: A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN …tu-freiberg.de/sites/default/files/media/professur... · A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN-UP. 4th International](https://reader031.vdocument.in/reader031/viewer/2022011813/5e369dac97a1747eb050b87f/html5/thumbnails/5.jpg)
5
Filter cakeremoved
Filter cakeremoved
Introduction -
Working principle of PBF
Granular mediumLouver
Clean gas
Filter cake
Dusty gasDusty gas
Gas Pulse
![Page 6: A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN …tu-freiberg.de/sites/default/files/media/professur... · A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN-UP. 4th International](https://reader031.vdocument.in/reader031/viewer/2022011813/5e369dac97a1747eb050b87f/html5/thumbnails/6.jpg)
6
Introduction – Filtration mode
Clean granular medium
Dirty GasClean Gas
Dirty GasClean GasFilter cake
rootsDirty GasClean Gas
Filter cake
Clean Gas Dirty Gas
![Page 7: A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN …tu-freiberg.de/sites/default/files/media/professur... · A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN-UP. 4th International](https://reader031.vdocument.in/reader031/viewer/2022011813/5e369dac97a1747eb050b87f/html5/thumbnails/7.jpg)
7
Introduction – Puff-back mode
Filter cakeOutermost
layersGas pulse
Local failure
Filter cakeOutermost
layers
Gas pulse
Body movement
gap
Gas pulse
Gap closing with new granular
Granular bed settled
Filter-cake roots remain intact
![Page 8: A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN …tu-freiberg.de/sites/default/files/media/professur... · A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN-UP. 4th International](https://reader031.vdocument.in/reader031/viewer/2022011813/5e369dac97a1747eb050b87f/html5/thumbnails/8.jpg)
8
Introduction – New Filter vs. previous design
![Page 9: A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN …tu-freiberg.de/sites/default/files/media/professur... · A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN-UP. 4th International](https://reader031.vdocument.in/reader031/viewer/2022011813/5e369dac97a1747eb050b87f/html5/thumbnails/9.jpg)
9
Introduction – Lab scale rig
Dirty gas compartment
Inlet cone
Feeding container
Outlet cone
Clean gas compartment
Collecting container
40 mm
![Page 10: A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN …tu-freiberg.de/sites/default/files/media/professur... · A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN-UP. 4th International](https://reader031.vdocument.in/reader031/viewer/2022011813/5e369dac97a1747eb050b87f/html5/thumbnails/10.jpg)
10
Experiment –
Operating ParametersFiltration dust:Arizona test dust, A1 & A2• Loose bulk density: 650 g/m3
• Mean diameter: 9 & 4 μm
Filtration medium:Sintered Bauxite• Sphericity: 0.9• Density: 2040 g/m3
• Mean diameter: 0.662 & 0.458 mm
![Page 11: A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN …tu-freiberg.de/sites/default/files/media/professur... · A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN-UP. 4th International](https://reader031.vdocument.in/reader031/viewer/2022011813/5e369dac97a1747eb050b87f/html5/thumbnails/11.jpg)
11
Experiment –
Operating Parameters
Operating Conditions DetailsTemperature 20 °C,120 °CVolume flow 6-35 m3/hFiltration velocity 2.50 to 14.94 cm/sInlet dust concentration 2–18 g/m3
Tank Pressure 7 bar absolutePulse duration 30 -
50 ms
Puff-back pressure drop 650,1500, 2000, 2500 PaSpill during each puff-back 150–200 g
![Page 12: A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN …tu-freiberg.de/sites/default/files/media/professur... · A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN-UP. 4th International](https://reader031.vdocument.in/reader031/viewer/2022011813/5e369dac97a1747eb050b87f/html5/thumbnails/12.jpg)
12
Experiment - Setup
![Page 13: A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN …tu-freiberg.de/sites/default/files/media/professur... · A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN-UP. 4th International](https://reader031.vdocument.in/reader031/viewer/2022011813/5e369dac97a1747eb050b87f/html5/thumbnails/13.jpg)
13
Results – Clean-bed Pressure drop
0
100
200
300
400
500
600
0 2 4 6 8 10 12 14 16Velocity [cm/s]
Cle
an-b
ed P
ress
ure
drop
[Pa]
New design-Filter tray Previous design-L10-56
![Page 14: A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN …tu-freiberg.de/sites/default/files/media/professur... · A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN-UP. 4th International](https://reader031.vdocument.in/reader031/viewer/2022011813/5e369dac97a1747eb050b87f/html5/thumbnails/14.jpg)
14
Results -
short term
0
200
400
600
800
1000
1200
1400
1600
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320
time [min]
Δp
[Pa]
0
1
2
3
4
5
6
Filtr
atio
n ve
loci
ty [c
m/s
]
Pressure drop Filtration velocity
1500 Pa
5 cm/s
150 Pa170 Pa 175 Pa
![Page 15: A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN …tu-freiberg.de/sites/default/files/media/professur... · A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN-UP. 4th International](https://reader031.vdocument.in/reader031/viewer/2022011813/5e369dac97a1747eb050b87f/html5/thumbnails/15.jpg)
15
Results - short term
0
200
400
600
800
1000
1200
1400
1600
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280time [min]
Δp
[Pa]
0
5
10
15
Filtr
atio
n ve
loci
ty [c
m/s
]
9.5 cm/s
1500 Pa
![Page 16: A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN …tu-freiberg.de/sites/default/files/media/professur... · A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN-UP. 4th International](https://reader031.vdocument.in/reader031/viewer/2022011813/5e369dac97a1747eb050b87f/html5/thumbnails/16.jpg)
16
Results – Inadequate cleaning
0
200
400
600
800
1000
1200
1400
1600
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160time [min]
Δp
[Pa]
![Page 17: A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN …tu-freiberg.de/sites/default/files/media/professur... · A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN-UP. 4th International](https://reader031.vdocument.in/reader031/viewer/2022011813/5e369dac97a1747eb050b87f/html5/thumbnails/17.jpg)
17
Results -
long term -
9,4 cm/s, 2 g/m3
0
200
400
600
800
1000
1200
1400
1600
1800
2000
2200
0 1 2 3 4 5 6 7 8 9 10111213141516171819202122232425262728293031323334353637383940414243
Filtration cycle
Δp
[Pa]
Δp after cleaning Δp before cleaning Δp at start-up
2000Pa
![Page 18: A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN …tu-freiberg.de/sites/default/files/media/professur... · A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN-UP. 4th International](https://reader031.vdocument.in/reader031/viewer/2022011813/5e369dac97a1747eb050b87f/html5/thumbnails/18.jpg)
18
Results –
extreme conditions: 3 cm/s, 18 g/m3
0
200
400
600
800
1000
1200
1400
1600
0 100 200 300 400Filtration time [min]
Δp
[Pa]
0
2
4
6
8
Filtr
atio
n ve
loci
ty [c
m/s
]
dP Filtration velocity
1500 Pa
3 cm/s
![Page 19: A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN …tu-freiberg.de/sites/default/files/media/professur... · A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN-UP. 4th International](https://reader031.vdocument.in/reader031/viewer/2022011813/5e369dac97a1747eb050b87f/html5/thumbnails/19.jpg)
19
Results –
PSD -
coarse particles
0
10
20
30
40
50
60
70
80
90
100
0,1 1,0 10,0 100,0Particle Size (µm)
Cum
ulat
ive
Volu
me
(%)
after experiment before experiment
7 μm4 μm
![Page 20: A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN …tu-freiberg.de/sites/default/files/media/professur... · A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN-UP. 4th International](https://reader031.vdocument.in/reader031/viewer/2022011813/5e369dac97a1747eb050b87f/html5/thumbnails/20.jpg)
20
Conclusion↓ number of louvers per unit module by ↑ gas-entry surface area per unit louverConstant residual pressure drop → sufficient pressure pulse transmitted during puff-back mode
Compared to previous panel bed filter designs:Lower initial and residual pressure dropLonger filtration cycles → reduced puff-back frequency
![Page 21: A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN …tu-freiberg.de/sites/default/files/media/professur... · A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN-UP. 4th International](https://reader031.vdocument.in/reader031/viewer/2022011813/5e369dac97a1747eb050b87f/html5/thumbnails/21.jpg)
21
Future work
•
Details
studies with
d50
= 4 μm•
SEM analysis of the filter cake structure
•
Emission/Penetration test•
Higher temperature
![Page 22: A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN …tu-freiberg.de/sites/default/files/media/professur... · A COMPACT GRANULAR BED FILTER FOR IGCC HOT GAS CLEAN-UP. 4th International](https://reader031.vdocument.in/reader031/viewer/2022011813/5e369dac97a1747eb050b87f/html5/thumbnails/22.jpg)