A 2 Four-wire Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators Limit Alarms Gateway, Remote I/O Paperless Recording System PC Recorder Electronic Actuators & Position Sensors Lightning Surge Protectors Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1 Mini-M Series Mini-MW Series M6 Series M5-UNIT Series W5-UNIT Series M3-UNIT Series M3S-UNIT Series Pico-M Series MX-UNIT Series M-UNIT Series W-UNIT Series K-UNIT Series F-UNIT Series H-UNIT Series 10-RACK Series 18-RACK Series 38-RACK Series Rack-mounted A Four-wire Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators Limit Alarms Gateway, Remote I/O Paperless Recording System PC Recorder Electronic Actuators & Position Sensors Lightning Surge Protectors 3 Mini-M Series Mini-MW Series M6 Series M5-UNIT Series W5-UNIT Series M3-UNIT Series M3S-UNIT Series Pico-M Series MX-UNIT Series M-UNIT Series W-UNIT Series K-UNIT Series F-UNIT Series H-UNIT Series 10-RACK Series 18-RACK Series 38-RACK Series Rack-mounted Specifications are subject to change without notice. ISP1-1 Four-wire Signal Conditioners Four-wire Signal Conditioners Four-wire Signal Conditioners Product Selection Guide Four-wire Product Selection Guide Four-wire Product Selection Guide mm (inch) Compact Plug-in Mini-M Series Compact Plug-in Signal Splitters Mini-MW Series Ultra-Slim M6 Series Low Profile M5-UNIT Series Low Profile Signal Splitters W5-UNIT Series Thin Profile M3-UNIT Series Thin Profile M3S-UNIT Series P.8 P.30 P.38 P.56 P.60 P.64 P.68 Construction Plug-in Plug-in Ultra-slim Terminal block Terminal block Front terminal access Front terminal access Connection M3 screw terminal M3 screw terminal Tension-clamp, M3 screw terminal Euro terminal M3.5 screw terminal Input: M3.5 screw terminal Output & power: M3 screw terminal Removable terminal block Removable terminal block Isolation Three ways Four ways Three / four ways Three ways Four ways Three ways Three / Four ways Dielectric Strength 2000V AC 2000V AC 2000V AC DC powered: 2000V AC AC powered: 1500V AC 2000V AC DC powered: 1000V AC AC powered: 1500V AC (M3LU) 2000V AC Range Selectability Specified when ordering or PC / One-Step Cal programming Specified when ordering or PC programming Specified when ordering or PC programming Specified when ordering Specified when ordering or DIP switch programming PC / One-Step Cal programming Specified when ordering or PC programming Dual Output Yes Selected models Yes Selected models Power Input AC / DC AC / DC DC AC / DC AC / DC AC / DC AC / DC (universal) Operating Temperature -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -20 to +55°C (-4 to +131°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -25 to +65°C (-13 to +149°F) -10 to +55°C (14 to 131°F) Mounting Surface or DIN rail Surface or DIN rail DIN rail DIN rail DIN rail DIN rail DIN rail Dimensions W23 [29.5] × H76 × D124 mm (0.91” [1.16”] × 2.99” × 4.88”) W29.5 × H89 × D124 mm (1.16” × 3.51” × 4.88”) M6D/S: W5.9 × H94 × D102 mm (0.23” × 3.70” × 4.02”) M6N: W7.5 × H102 × D102 mm (0.30” × 4.02” × 4.02”) W25 × H97 × D41 mm (0.98” × 3.82” × 1.61”) W45 × H97 × D41 mm (1.77” × 3.82” × 1.61”) W18 × H106 × D110.5 mm (0.71” × 4.17” × 4.35”) W12 × H106 × D110.5 mm (0.47” × 4.17” × 4.35”) Standards & Approvals CE / UL / C-UL CE / UL / C-UL CE (UL / C-UL pending) CE CE CE / UL / C-UL (DC powered only) CE Mini-M Series Mini-MW Series M6 Series M5-UNIT W5-UNIT M3-UNIT M3S-UNIT Input Loop Powered Isolator M2SN M6xSN M5SN Universal Input M2XU, M2XUM M3LU DC Input M2XV2, M2LV, M2VS, M2VF, M2VF2, M2VV W2VS, W2VF M6xYV, M6xXV, M6xVS, M6xWVS M5VS, M5MV, M5VF W5VS, W5FV M3LV M3SYV, M3SXV, M3SVS, M3SWVS High Current Output Thermocouple Input M2XT2, M2TS W2TS M6xXT M5TS W5TS M3LT M3SXT RTD Input M2XR2, M2LR, M2RS, M2RR W2XR, W2RS M6xXR M5RS W5RS M3LR M3SXR, M3SRS Potentiometer Input M2XM2, M2LPM, M2MS W2XM, W2MS M6xXM M5MS W5MS M3LM M3SXM, M3SMS Current Loop Supply M2D, M2D2, M2DYS, M2DY, M2DL, M2DNY, M2DYH, M2DU W2DYS, W2DY, W2DNY, W2DYH M6xDY M5DY W5DY M3LDY, M3DY M3SDY Self-Synch Input Strain Gauge Input M2LCS W5LCS M3LLC AC Input M2TG, M2AC W2TG, W2AC PT Input M2PA, M2PE W2PA, W2PE M5PT CT Input M2CA, M2CE, M2CEC W2CA, W2CE M6xCTC M5CT, M5CTC Power Transducer Frequency Input M2XPA3, M2XPA2, M2SP W2SP M6xPA M5PA W5PA M3LPA Encoder Input M2XRP2 Frequency Output M2AP W2AP Pulse Isolator M2PP W2PP Pulse Scaler M2PRU P/I Transducer M2PV W2PV I/P Transducer Limit Alarm M2AVS, M2SED, M2AS, M2AS1 M6xXAS BCD Transducer Math Function M2ADS, M2SBS, M2MLS, M2DIS M6xXF2 Ratio/Bias M2REB, M2RTS Process Function M2XF2, M2FL, M2FLS, M2LMS, M2UDS2, M2UDS M6xXF1 Filter/Lag M2CDS, M2CRS M6xXF1 Hold M2AMS2, M2AMS, M2PHS2, M2PHS M6xXF3 Signal Selector M2SES2, M2SES, M2MNV M6xXF2 Signal Generator M2MST Valve Positioner Control Backup Others Four-wire Signal Conditioners Product Selection Guide

Upload: others

Post on 29-May-2020

15 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: A Four-wire Signal Conditioners Product Selection Guide ... · Four-wire Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators Limit Alarms Gateway, Remote

A

2

Four-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors Lightning Surge Protectors

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1

Mini-M Series

Mini-MW Series

M6 Series

M5-UNIT Series

W5-UNIT Series

M3-UNIT Series

M3S-UNIT Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

H-UNIT Series

10-RACK Series

18-RACK Series

38-RACK Series Rack

-mou

nted

AFour-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors

Lightning Surge Protectors

3

Mini-M Series

Mini-MW Series

M6 Series

M5-UNIT Series

W5-UNIT Series

M3-UNIT Series

M3S-UNIT Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

H-UNIT Series

10-RACK Series

18-RACK Series

38-RACK SeriesRack

-mou

nted

Specifications are subject to change without notice.ISP1-1

Four

-wire

Sig

nal C

ondi

tione

rs

Four

-wire

Sig

nal C

ondi

tione

rs

Four-wire Signal Conditioners Product Selection Guide

Four-wire Product Selection Guide

Four-wire Product Selection Guide

mm (inch)

Compact Plug-in Mini-M Series

Compact Plug-in Signal Splitters Mini-MW Series

Ultra-Slim M6 Series

Low Profile M5-UNIT Series

Low Profile Signal Splitters W5-UNIT Series

Thin Profile M3-UNIT Series

Thin Profile M3S-UNIT Series

P.8 P.30 P.38 P.56 P.60 P.64 P.68

Construction Plug-in Plug-in Ultra-slim Terminal block Terminal block Front terminal access Front terminal access

Connection M3 screw terminal M3 screw terminal Tension-clamp, M3 screw terminal Euro terminal M3.5 screw terminal Input: M3.5 screw terminal

Output & power: M3 screw terminal Removable terminal block Removable terminal block

Isolation Three ways Four ways Three / four ways Three ways Four ways Three ways Three / Four ways

Dielectric Strength 2000V AC 2000V AC 2000V AC DC powered: 2000V AC AC powered: 1500V AC 2000V AC DC powered: 1000V AC

AC powered: 1500V AC (M3LU) 2000V AC

Range Selectability Specified when ordering or PC / One-Step Cal programming

Specified when ordering or PC programming

Specified when ordering or PC programming Specified when ordering Specified when ordering or

DIP switch programming PC / One-Step Cal programming Specified when ordering or PC programming

Dual Output – Yes Selected models – Yes – Selected models

Power Input AC / DC AC / DC DC AC / DC AC / DC AC / DC AC / DC (universal)

Operating Temperature -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -20 to +55°C (-4 to +131°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -25 to +65°C (-13 to +149°F) -10 to +55°C (14 to 131°F)

Mounting Surface or DIN rail Surface or DIN rail DIN rail DIN rail DIN rail DIN rail DIN rail

Dimensions W23 [29.5] × H76 × D124 mm (0.91” [1.16”] × 2.99” × 4.88”)

W29.5 × H89 × D124 mm (1.16” × 3.51” × 4.88”)

M6D/S: W5.9 × H94 × D102 mm (0.23” × 3.70” × 4.02”) M6N: W7.5 × H102 × D102 mm (0.30” × 4.02” × 4.02”)

W25 × H97 × D41 mm (0.98” × 3.82” × 1.61”)

W45 × H97 × D41 mm (1.77” × 3.82” × 1.61”)

W18 × H106 × D110.5 mm (0.71” × 4.17” × 4.35”)

W12 × H106 × D110.5 mm (0.47” × 4.17” × 4.35”)

Standards & Approvals CE / UL / C-UL CE / UL / C-UL CE (UL / C-UL pending) CE CE CE / UL / C-UL (DC powered only) CE

Mini-M Series Mini-MW Series M6 Series M5-UNIT W5-UNIT M3-UNIT M3S-UNIT

Input Loop Powered Isolator M2SN – M6xSN M5SN – – –Universal Input M2XU, M2XUM – – – – M3LU –

DC Input M2XV2, M2LV, M2VS, M2VF, M2VF2, M2VV W2VS, W2VF M6xYV, M6xXV, M6xVS,

M6xWVS M5VS, M5MV, M5VF W5VS, W5FV M3LV M3SYV, M3SXV, M3SVS, M3SWVS

High Current Output – – – – – – –Thermocouple Input M2XT2, M2TS W2TS M6xXT M5TS W5TS M3LT M3SXT

RTD Input M2XR2, M2LR, M2RS, M2RR W2XR, W2RS M6xXR M5RS W5RS M3LR M3SXR, M3SRSPotentiometer Input M2XM2, M2LPM, M2MS W2XM, W2MS M6xXM M5MS W5MS M3LM M3SXM, M3SMS

Current Loop Supply M2D, M2D2, M2DYS, M2DY, M2DL, M2DNY, M2DYH, M2DU

W2DYS, W2DY, W2DNY, W2DYH M6xDY M5DY W5DY M3LDY, M3DY M3SDY

Self-Synch Input – – – – – – –Strain Gauge Input M2LCS – – – W5LCS M3LLC –

AC Input M2TG, M2AC W2TG, W2AC – – – – –PT Input M2PA, M2PE W2PA, W2PE – M5PT – – –CT Input M2CA, M2CE, M2CEC W2CA, W2CE M6xCTC M5CT, M5CTC – – –

Power Transducer – – – – – – –Frequency Input M2XPA3, M2XPA2, M2SP W2SP M6xPA M5PA W5PA M3LPA –Encoder Input M2XRP2 – – – – – –

Frequency Output M2AP W2AP – – – – –Pulse Isolator M2PP W2PP – – – – –Pulse Scaler M2PRU – – – – – –

P/I Transducer M2PV W2PV – – – – –I/P Transducer – – – – – – –

Limit Alarm M2AVS, M2SED, M2AS, M2AS1 – M6xXAS – – – –BCD Transducer – – – – – – –Math Function M2ADS, M2SBS, M2MLS, M2DIS – M6xXF2 – – – –

Ratio/Bias M2REB, M2RTS – – – – – –

Process Function M2XF2, M2FL, M2FLS, M2LMS, M2UDS2, M2UDS – M6xXF1 – – – –

Filter/Lag M2CDS, M2CRS – M6xXF1 – – – –

Hold M2AMS2, M2AMS, M2PHS2, M2PHS – M6xXF3 – – – –

Signal Selector M2SES2, M2SES, M2MNV – M6xXF2 – – – –Signal Generator M2MST – – – – – –Valve Positioner – – – – – – –Control Backup – – – – – – –

Others – – – – – – –

Four-wire Signal Conditioners Product Selection Guide

Page 2: A Four-wire Signal Conditioners Product Selection Guide ... · Four-wire Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators Limit Alarms Gateway, Remote

A

4

Four-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors Lightning Surge Protectors

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1

Mini-M Series

Mini-MW Series

M6 Series

M5-UNIT Series

W5-UNIT Series

M3-UNIT Series

M3S-UNIT Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

H-UNIT Series

10-RACK Series

18-RACK Series

38-RACK Series Rack

-mou

nted

AFour-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors

Lightning Surge Protectors

5

Mini-M Series

Mini-MW Series

M6 Series

M5-UNIT Series

W5-UNIT Series

M3-UNIT Series

M3S-UNIT Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

H-UNIT Series

10-RACK Series

18-RACK Series

38-RACK SeriesRack

-mou

nted

Specifications are subject to change without notice.ISP1-1

Four

-wire

Sig

nal C

ondi

tione

rs

Four

-wire

Sig

nal C

ondi

tione

rs

Four-wire Signal Conditioners Product Selection Guide

Four-wire Product Selection Guide

Four-wire Product Selection Guide

mm (inch)

Dual Output Super-mini Signal Conditioners

Pico-M SeriesPlug-in Front Configurable

MX-UNIT SeriesPlug-in

M-UNIT SeriesPlug-in Signal Splitters

W-UNIT SeriesPlug-in

K-UNIT SeriesSpace-saving Plug-in

F-UNIT SeriesSpace-saving Plug-in

H-UNIT Series

Construction Connector on the base Plug-in Plug-in Plug-in Plug-in Plug-in Plug-in

Connection M3.5 screw terminal, DCS M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal

Isolation Four ways Three ways Three ways Four ways Three / four ways Three ways Three ways

Dielectric Strength 1500V AC 2000V AC 2000V AC 2000V AC 2000V AC 1000V AC 500V AC

Range Selectability Specified when ordering or PC programming Front key programming Specified when ordering or

PC / Programming unit programmingSpecified when ordering or

PC / Programming unit programming Specified when ordering Specified when ordering or PC / Programming unit programming

Specified when ordering or PC / Programming unit programming

Dual Output Yes – – Yes Selected models – –

Power Input AC / DC AC / DC AC / DC AC / DC AC / DC AC / DC DC

Operating Temperature 0 to 55°C (32 to 131°F) -5 to +55°C (23 to 131°F) -5 to +60°C (23 to 140°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F)

Mounting Installation Base (Surface) Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail

Dimensions W17.5 × H48 × D75 mm (0.69” × 1.89” × 2.95”)

W50 × H80 × D123 [132] mm (1.97” × 3.15” × 4.84” [5.20”] )

W50 × H80 × D127 [136] mm (1.97” × 3.15” × 5” [5.35”] )

W50 × H80 × D136 mm (1.97” × 3.15” × 5.35”)

W50 × H80 × D123 [132] mm (1.97” × 3.15” × 4.84” [5.20”] )

W26 × H100 × D137 mm (1.02” × 3.94” × 5.39”)

W26 × H93 × D137 mm (1.02” × 3.66” × 5.39”)

Standards & Approvals CE CE CE / UL / C-UL for selected models CE for selected models CE for selected models – –

Pico-M Series MX-UNIT M-UNIT W-UNIT K-UNIT F-UNIT H-UNIT

Input Loop Powered Isolator – – SN – KSN FSN HSNUniversal Input – – JUA – – – –

DC Input M8YV1, M8XV3, M8VS1, M8YS1, M8YC1 MXV, MXF JV, SV, SVF, CV, OT2, OR2 WJV, WVS, WVS2, WVF KYV, KVS, KWVS,

KWVS2, KSF, KV FJV, FVS, FVF, FV HJV, HVS, HVF, HV

High Current Output – – VA, SVA, 99SVA – – – –Thermocouple Input M8XT3, M8TS1 MXT JT, TCS, OTT2, OTR2 WJT, WTS KTS, KWTS FJT, FTS HJT, HTS

RTD Input M8XR3, M8RS1 MXR JR, RB, RBS, DR, DRS, CVRTD WJR, WRS, WRS2 KR, KRS, KWRS, KWRS2 FJR, FR, FRS HJR, HR, HRSPotentiometer Input M8XM3, M8MS1 – JM, PM, PMS, CVR1 WJM, WMS, WMS2 KM, KMS, KWMS, KWMS2 FJM, FM, FMS HJM, HM, HMS

Current Loop Supply M8DY1 – DS, DS-48, JDL, YVD, YVDU, FND, FNDS WDY, WDNY KD, KDY, KWDY, KWDNY,

KWLD FD, FJDL, FDY2, FDL, FDU HD, HJDL, HDY2, HDL, HDU

Self-Synch Input – MXS JS WJS – – –Strain Gauge Input M8LCS MXLC, MXLCF LC, LCS, LC2, LCS2, LCF, MLV – KG, KGS FLC, FLCS –

AC Input – – TG, AC WTG, WAC KTG, KAC FTG, FAC –PT Input M8PT – PT, PTPH, PTAF WPT KP, KPE, KPNA, KPNE FPA, FPE HPA, HPE

CT Input M8CT1, M8CTC – CTH, CTC, CTCS, CTS, CT, CTPH,CTAF WCT KCEC, KC, KCE,

KCNA, KCNE, KCEZ FCA, FCE HC, HCE

Power Transducer – – MUWT, MEWT, MEWTF, MERP, MEPF, MEPA, HZ

WEWT, WERP, WEPF, WEPA, WHZ – – –

Frequency Input M8PA1 MXPA JPA, JPA2, MPAU, JPQ2, EP, SP, JTY2 WJPAD, WJPA, WSP KEP, KSP, KPAU FJPA, FSP HJPA, HSPEncoder Input – – JRP2, JRQ2, RPPD, JARP – – – –

Frequency Output M8AP1 MXAP AP, APU, JAPD, JARP, MTD – KAP, KAPU FAP HAP, HAPUPulse Isolator M8PP1 – PP, PPD, YPD, RPPD, MNS WYPD KMT, KYPD, KWYPD FPP HPPPulse Scaler – – JPR2, PRU, JFR2, PDU, JPS3, JPS2 – KPRU – HPR

P/I Transducer – – PV – – – HPVI/P Transducer – – VP – – – HVP, HVPN

Limit Alarm M8SED1 –AS4V, AS4T, AS4R, AS4M, AS4CT,

AS4LC, MSEF, AS, ASW, ASW2, ASL, ASWL, ASWL2, AYAV, AYDV, ASD1, ASD

– KS2V, KS2TR, KSED, KSE, KS, KS2, KSL, KSL2 FAS, FASD HAS

BCD Transducer – – AD3V, AD2LC, DA3 – – – –Math Function – – JF, JFK, ADS, SBS, MLS, DIS WJF, WJFK, WADS KADS, KSBS, KMLS, KDIS FJF HJF

Ratio/Bias – – REB, REBS, RT, RTS – KB, KBS FRT, FRTS, FRTD –

Process Function – MXF JFX, JFX1, FN, FNS, LM, LMS, UD, UDS, MLG WJFX KX, KN, KNS, KL, KLS, KU, KUS FJFX, FFL, FLM, FLMS, FUD,

FUDS HJFX, HN

Filter/Lag M8CD1 – JFT, JFTS, CD, CDS, CR, CRS WJFT KF, KFS FJFT, FCR, FCRS HJFTHold – – AM, AMS, PH, PHS – KA, KAS, KH, KHS – –

Signal Selector – – SE, SES, MNV – – FSE, FSES –Signal Generator – MXMS MS, MFS, MFS2 – – – –

Valve Positioner – – ABM, MP, MEX-B, MEX-C, MEX-D, MEX-E, MEX-F, MEX-M1 – – – –

Control Backup – MXAB, MXCB JB2, AB2, CB2 – – – –Others – – MDC (Excitation Supply) – – – –

Four-wire Signal Conditioners Product Selection Guide

Page 3: A Four-wire Signal Conditioners Product Selection Guide ... · Four-wire Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators Limit Alarms Gateway, Remote

A

6

Four-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors Lightning Surge Protectors

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1

Mini-M Series

Mini-MW Series

M6 Series

M5-UNIT Series

W5-UNIT Series

M3-UNIT Series

M3S-UNIT Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

H-UNIT Series

10-RACK Series

18-RACK Series

38-RACK Series Rack

-mou

nted

AFour-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors

Lightning Surge Protectors

7

Mini-M Series

Mini-MW Series

M6 Series

M5-UNIT Series

W5-UNIT Series

M3-UNIT Series

M3S-UNIT Series

Pico-M Series

MX-UNIT Series

M-UNIT Series

W-UNIT Series

K-UNIT Series

F-UNIT Series

H-UNIT Series

10-RACK Series

18-RACK Series

38-RACK SeriesRack

-mou

nted

Specifications are subject to change without notice.ISP1-1

Four

-wire

Sig

nal C

ondi

tione

rs

Four

-wire

Sig

nal C

ondi

tione

rs

Four-wire Signal Conditioners Product Selection Guide

Four-wire Product Selection Guide

Four-wire Product Selection Guide

mm (inch)

Dual Output 10-RACK Series

DCS Front End 18-RACK Series

Interposing Relays 38-RACK Series

Construction Rack-mounted Rack-mounted Rack-mounted

Connection M3.5 screw terminal, DCS M3.5 screw terminal, DCS M3.5 screw terminal

Isolation Four ways Four ways –

Dielectric Strength 500V AC 1500V AC –

Range Selectability Specified when ordering or PC / Programming unit programming

Specified when ordering or PC / Programming unit programming –

Dual Output Yes Yes –

Power Input AC / DC AC / DC DC

Operating Temperature -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F)

Mounting Standard rack Standard rack Standard rack

Dimensions W25 × H99 × D180 mm (0.98” × 3.90” × 7.09”)

W24 × H110 × D110 mm (0.94” × 4.33” × 4.33”)

W24 × H110 × D110 mm (0.94” × 4.33” × 4.33”)

Standards & Approvals – – –

10-RACK 18-RACK 38-RACK

Input Loop Powered Isolator 10SN 18SNUniversal Input – –

DC Input 10VS4, 10YS, 10YK, 10JV, 10VS, 10VK, 10VF

18YS, 18YK, 18YC, 18JV, 18VS, 18VK

High Current Output – –Thermocouple Input 10JT, 10TS, 10TK 18JT, 18TS, 18TK

RTD Input 10JR, 10JRE, 10RS, 10RK 18JR, 18RS, 18RKPotentiometer Input 10JM, 10MS, 10MK 18JM, 18MS, 18MKCurrent Loop Supply 10D, 10JDL, 10DY, 10DNY, 10DU 18JDL, 18DY, 18JDN, 18DU

Self-Synch Input – –Strain Gauge Input 10LCS, 10LCK –

AC Input 10TG, 10AC 18TG, 18ACPT Input 10PA, 10PE 18PECT Input 10CA, 10CE 18CE

Power Transducer 10EWT, 10ERP, 10EPF, 10EPA, 10EHZ 18WT, 18RP, 18PF, 18PA, 18HZFrequency Input 10JPA, 10SP 18JPAEncoder Input – –

Frequency Output 10AP –Pulse Isolator 10PP 18PPPulse Scaler 10PR 18PR

P/I Transducer 10PV 18PVI/P Transducer 10VP, 10VPN 18VP

Limit Alarm 10AS 18AS2, 18AT, 18ARBCD Transducer – –Math Function 10JF 18JF

Ratio/Bias – –Process Function 10JFX, 10FNS 18JFX, 18JN

Filter/Lag 10JFT –Hold – –

Signal Selector – –Signal Generator – –Valve Positioner – –Control Backup 10ABS –

Others 10BOS 18DI, 18DO, 18APT, 18YVT

Visit M-System Web Site.

Four-wire Signal Conditioners Product Selection Guide

n PC Configurator SoftwareM-System’s PC Configurator programs are packed with advanced features. Not only the I/O ranging, but also linearization, fine calibration, filters, diagnostics are available depending on the signal conditioner’s function. In addition, many configurators are provided with monitoring and simulating functions to help you confirm the module’s proper operation, calibrate it at the field site and commissioning the receiving instrument at the same time.

This type of programming is especially convenient when an identical configuration setting is required for multiple modules. It saves you a considerable time by simply calling a pre-defined setting and downloading it from the PC software.

The PC configuration is available with various signal conditioner series including M2X, M3L, M3SX and M6X Series.

n “One-Step Cal” ConfigurationEven when you do not have a PC at your disposal, a simulator and a multimeter can help you program I/O ranges.

The internal DIP switches are used to configure input and output type. Once the module is configured, precise ranges can be set with the front control buttons using a simulator connected to the input terminals and a multimeter connected to the output terminals as a reference.

For example, suppose that the DIP switches are configured for the J type thermocouple. Turn the power supply to the transmitter on and press MODE button to enter to the Input Calibration Mode. Apply the desired minimum (e.g. 0°C) and maximum (e.g. 400°C) input levels and push the DOWN (zero) and UP (span) respectively to set the input range to 0 to 400°C. Then the output range can be calibrated in a similar manner after moving to the Output Calibration Mode.

The front LED’s colors and flashing patterns help you easily identify the transmitter’s status and confirm the setup actions in each step of Calibration Modes.

“One-Step Cal” configuration is available with the M3L and M2L Series signal conditioners.

n Front Control Buttons with Local DisplayThe MX Series signal conditioners and the AS4 Series limit alarms are provided with two displays on the front face: 4-digit DATA display and 2-digit ITEM display. Using Up/Down buttons, configuration is simple by calling parameters’ ID numbers (ITEM) and choosing values (DATA).

The M7E Series limit alarms are provided with a multi-line LCD display, which shows the parameters and selections in text to guide you through the programming procedure: intuitive, easy programming just like operating your mobile phone. You won’t need to consult the instruction manual.

These displays indicate process values once commissioned at the field site, and the soft-ware’s “programmable” mode can be locked out in order to prevent unwanted changes in the setting.

Configurable Signal Conditioners — Choose your way of configuration.

Basic Setting View Trend Graph View

MODE Button

DOWN Button

UP Button

LCD Display

Mode Button

Set Button

PC ConfiguratorJack

Up Button

Down ButtonITEM No. Display

DATA UP-DOWN Keys

ITEM No. UP-DOWN Keys

DATA Display

ProgrammingError LED

Polarity LED

MX Series Front Panel M7E Series Front Panel

Connect the M3LU to a simulator and a multimeter and to a power source.

SimulatorMultimeter

Power Source

Input Output

M3SX Series

M3L Series Front Panel

Page 4: A Four-wire Signal Conditioners Product Selection Guide ... · Four-wire Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators Limit Alarms Gateway, Remote

B

76

Four-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors Lightning Surge Protectors

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1

Two-wire Product Selection Guide

27-UNIT Series

26-UNIT Series

B6-UNIT Series

B3-UNIT Series

B5-UNIT Series

6-UNIT Series

T-UNIT Series

B-UNIT Series

Two-

wire

Sig

nal C

ondi

tione

rs

Two-wire Signal Conditioners Product Selection Guide BFour-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors

Lightning Surge Protectors

77

Two-wire Product Selection Guide

Two-wire Signal Conditioners Product Selection Guide

27-UNIT Series

26-UNIT Series

B6-UNIT Series

B3-UNIT Series

B5-UNIT Series

6-UNIT Series

T-UNIT Series

B-UNIT Series

Two-

wire

Sig

nal C

ondi

tione

rs

Specifications are subject to change without notice.ISP1-1

Head-mount, Programmable 27-UNIT Series

Head-mount 26-UNIT Series

Field-mount B6-UNIT Series

DIN Rail Mount B3-UNIT Series

Low Profile B5-UNIT Series

Hockey-puck Style 6-UNIT Series

Compact Size T-UNIT Series

Space-saving, Plug-in B-UNIT Series

P.78 P.82 P.84 P.86 P.90

Construction Sensor head-mounting Sensor head-mounting Outdoor enclosure (IP65) Front terminal access Terminal block Hockey-puck style Stand-alone; terminal access at the front Plug-in

Connection M3 screw terminal Terminal block M3.5 screw terminal Removable terminal block M3.5 screw terminal M3 screw terminal DIN terminal block M3.5 screw terminal

Isolation Input to output Input to output Input to output to outdoor enclosure Input to output Input to output Input to output Input to output Input to output

Dielectric Strength 1500V AC 1500V AC 1500V AC 2000V AC 2000V AC 500V AC 500V AC 500V AC

Range Selectability PC or HART programming Specified when ordering HART (PC) programmingSpecified when ordering or HART (PC) / PROFIBUS-PA

(PC) / DIP switch programmingSpecified when ordering Specified when ordering or

DIP switch programming Specified when ordering Specified when ordering

Operating Temperature -40 to +85°C (-40 to +185°F)

-40 to +85°C (-40 to +185°F)

-40 to +85°C (-40 to +185°F)

-40 to +85°C(-40 to +185°F)

-40 to +80°C (-40 to +176°F)

-5 to +70°C (23 to 158°F)

-5 to +60°C (23 to 140°F)

-5 to +55°C (23 to 131°F)

Mounting Head mount or Field mount Head mount Field mount DIN rail DIN rail DIN rail

with mounting plate A-31 Surface or DIN rail Surface or DIN rail

Dimensions 44 dia. × 20.7 mm (1.732 dia. × 0.81”)

43.5 dia. × 26.5 mm (1.71 dia. × 1.04”) 110 (4.33”) dia. W18 × H106 × D110.5 mm

(0.71” × 4.17” × 4.35”)W25 × H97 × D41 mm (0.98” × 3.82” × 1.61”)

W76 × H52.5 × D61 mm(2.99” × 2.07” × 2.40”)

W25 × H60 × D70 mm (0.98” × 2.36” × 2.76”)

W26 × H93 × D137 mm (1.02” × 3.66” × 5.39”)

Standards & Approvals CE / ATEX / FM / SIL2 CE / ATEX CE / ATEX / FM / SIL CE / UL / C-UL / ATEX / FM CE – – –

27-UNIT 26-UNIT B6-UNIT B3-UNIT B5-UNIT 6-UNIT T-UNIT B-UNIT

Input Loop Powered Isolator – – – – B5SN 6SN TSN BSN

DC Input – – – B3VS/1 (single channel) B3VS/2 (dual channel) B5VS – TV, TVS BV, BVS

DC Input (programmable) – – – B3FV – 6VS – –

Universal Temperature Input(HART, outdoor enclosure) 27HU-B – B6U-B – – – – –

Universal Temperature Input (HART) 27HU – B6U B3HU – – – –

Universal Temperature Input (PROFIBUS-PA) – – – B3PU – – – –

Universal Temperature Input 27U – – – – – – –Thermocouple Input – 26TS1 – – B5TS 6TS – BT, BTSThermocouple Input

(programmable) 27TS – – B3FT – 6TS1 – –

RTD Input – 26REX, 26R1, 26RS – – B5RS – TR BRRTD Input

(programmable) 27R, 27RS – – B3FR – 6R – –

Potentiometer Input – – – – B5MS 6M TM BMStrain Gauge Input – – – – – 6LC – BLC

Frequency Input – – – – – – – BSPFrequency Input (programmable) – – – B3FP – 6PA – –

Square Root Extractor – – – – – 6FN – –AC Input – – – – – 6AC – –PT Input – – – – – 6PT – BPTCT Input – – – – – 6CT – BCT

P/I Transducer – – – – – – TPV BPV

6BX-E

Page 5: A Four-wire Signal Conditioners Product Selection Guide ... · Four-wire Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators Limit Alarms Gateway, Remote

C

94

Four-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors Lightning Surge Protectors

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1

Power TransducersProduct Selection Guide

LT-UNIT Series

53U / 52U / 51U

LSMT3

LSMT2

K-UNIT Series

CLS Series

Power Transducers Products Selection Guide

L-UNIT Series

Pow

er T

rans

duce

rs

CFour-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors

Lightning Surge Protectors

95

Power TransducersProduct Selection Guide

Power Transducers Products Selection Guide

LT-UNIT Series

53U / 52U / 51U

L-UNIT Series

LSMT3

K-UNIT Series

LSMT2

Pow

er T

rans

duce

rs

Specifications are subject to change without notice.ISP1-1

Multi Power Transducer LSMT3

Multi Power Transducer LSMT2

Construction Terminal access at the front Terminal access at the front

Connection Connector type screw terminal block

Input and aux. supply: M4 screw terminal,

Output: M3.5 screw terminal

Dielectric Strength 3700V AC 2000V AC

Auxiliary Power AC / DC (universal) AC / DC

Operating Temperature -10 to +55°C (14 to 131°F)

-10 to +55°C (14 to 131°F)

Mounting DIN rail Surface or DIN rail

Dimensions W105 × H69.1 × D112.5 mm(4.13” × 2.72” × 4.43”)

W120 × H100 × D128 mm(4.72” × 3.94” × 5.04”)

Standars & Approvals CE –

Configuration

Single phase 3-phase / 3-wire balanced / Unbalanced load3-phase / 4-wire balanced / Unbalanced load

••

3-phase / 3-wire Single-phase / 2-wireSingle-phase / 3-wire3-phase / 4-wire

••••

Output Analog output, 3 points

Current Voltage

4 – 20mA DC0 – 1mA DC

0 – 10V DC0 – 5V DC1 – 5V DC

Watthours

Multi Power Monitor 53U

P.104

Construction 96-mm square (1/4 DIN size)

Connection;Voltage input Connector type terminal block

Dielectric Strength 2500V AC

Auxiliary Power AC / DC (universal)

Operating Temperature -10 to +55°C (14 to 131°F)

Mounting Panel Flush Mounting

Dimensions W96 × H96 × D115 mm (3.78” × 3.78” × 4.53”)

Degree of protection IP 50 (Front panel)

Standards & Approvals CE

Configuration Single-phase / 2-wire and 3-wire,3-phase / 3-wire and 4-wire

External Interface

Modbus, Do × 1, Di × 14 – 20mA DC × 41 – 5V DC × 44 – 20mA DC × 2, Do × 1, Di × 11 – 5V DC × 2, Do × 1, Di × 14 – 20mA DC × 2, Do × 21 – 5V DC × 2, Do × 2Modbus, Do × 3Do × 4

•••••••••

M4 Screw Connection LT-UNIT Series

M3.5 Screw Connection L-UNIT Series

Plug-in K-UNIT Series

P.96

Construction Terminal access at the front Terminal access at the front Plug-in

Connection M4 screw terminal M3.5 screw terminal M3.5 screw terminal

Dielectric Strength 2000V AC 2000V AC 2000V AC

Auxiliary Power AC / DC AC / DC AC / DC

Self Powered Type Available Available Available

Operating Temperature -10 to +55°C (14 to 131°F)

-10 to +55°C (14 to 131°F)

-10 to +55°C (14 to 131°F)

Mounting Surface or DIN rail Surface or DIN rail Surface or DIN rail

Dimensions W39 [72] × H111 × D143 mm (1.54” [2.83] × 4.37” × 5.63”)

W75 × H80 × D112 mm (2.95” × 3.15” × 4.41”)

W50 [72] × H80 × D123 [132] mm (1.97” [5.20”] × 3.15” × 4.84” [2.83”])

IEC 60688 Yes – –

Standards & Approvals CE – –

LT-UNIT L-UNIT K-UNIT

n PT TransducerAverage – LPNA KP, KPNA

RMS LTPE LPE, LPNE KPE, KPNE2 channels, Average – L2PA, L2PNA –

2 channels, RMS – L2PE, L2PNE –3 channels – L3PK –

n CT TransducerClamp-on Current Sensor;

RMS sensing LTCEC – KCEC

Average – LCNA KC, KCNARMS LTCE, LTCNE LCE, LCNE KCE, KCNE

2 channels, Average – L2CA, L2CNA –2 channels, RMS – L2CE, L2CNE –

3 channels – L3CK –

n PT/CT TransducerAverage – LPCA –

RMS – LPCE –

n Watt / Var / Power Factor / Phase Angle / Frequency / Bidirectional Current Transducer

Watt LTWT, LTWTN LWT, LWTNKEWT, KEWTN,KUWT, KUWTN,KUWE, KUWEN

Var LTRP, LTRPN LRP, LRPN KERP, KERPN,KURE, KUREN

Power Factor LTPF, LTPFN LPF, LPFN KEPF, KEPFNPower Factor

(for unbalanced load) LTPFU, LTPFUN LPFU, LPFUN KEPFU, KEPFUN

Phase Angle(self-powered) LTPA, LTPAN LPA, LPAN KEPA, KEPAN

Phase Angle(for unbalanced load) LTPAU, LTPAUN LPAU, LPAUN KEPAU, KEPAUN

Frequency LTHZ, LTHZN LHZ, LHZN KEHZ, KEHZNBidirectional Current – LCY –

Phase Angle(between two voltages) – LPD –

n ZCT TransmitterZCT

(zero-phase current transformer) – – KCEZ

n Limit AlarmQuad DC Alarm – L4AS –

CLS Series

Clamp-on Current Sensor CLS Series

CLSA / CLSB / CLSC / CLSD / CLSE

P.107

Page 6: A Four-wire Signal Conditioners Product Selection Guide ... · Four-wire Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators Limit Alarms Gateway, Remote

D

110

Bargraph Indicators

Digital Panel Meters

6DV Series

43 Series

Four-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors Lightning Surge Protectors

Indi

cato

rs

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1

D

Bargraph Indicators

Digital Panel Meters

6DV Series

43 Series

Four-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors

Lightning Surge Protectors

Indi

cato

rs

111Specifications are subject to change without notice.ISP1-1

Indicators Products Selection Guide

IndicatorsProduct Selection Guide

IndicatorsProduct Selection Guide

Bargraph Indicator 48NV

Bargraph Indicating Alarm Bargraph Indicating Alarmwith 4-digit digital meter

Bargraph Indicating Alarm(Sensor Input)

Bargraph Indicating Alarm with 4-digit digital meter

(Sensor Input)Bargraph Indicator

48SVBargraph Indicating Alarm

49AV2

P.114 P.114 P.114 P.114 P.114

Bargraph 101-segment LED 101-segment LED 101-segment LED 101-segment LED 101-segment LED 51-segment LED 51-segment LED

Scale Length 100 mm (3.96”) long,3.00 mm (.12”) wide

100 mm (3.96”) long,3.00 mm (.12”) wide

100 mm (3.96”) long,3.00 mm (.12”) wide

100 mm (3.96”) long,3.00 mm (.12”) wide

100 mm (3.96”) long,3.00 mm (.12”) wide 50 mm (1.97”) long 89 mm (3.50”) long,

angle 120°

Scale Custom Custom Custom Custom Custom 0 – 100% 0 – 100%

Bar Color Red, Amber, Green, Blue Red, Amber, Green, Blue, Multi-color

Red, Amber, Green, Blue, Multi-color

Red, Amber, Green, Blue, Multi-color

Red, Amber, Green, Blue, Multi-color Red Multi-color

(Red, Orange and Green)

Digital Meter – – 4 digits, Red LED – 4 digits, Red LED – 4 digits, Red LED

Connection M3 screw terminal M3 screw terminal M3 screw terminal M3 screw terminal M3 screw terminal Connector(leadwires soldered) M4 screw terminal

Direct Sensor Input – – – Yes Yes – –

Excitation Supply – Optional Optional – – – –

Alarm Output – 2 or 4 points 2 or 4 points 2 or 4 points 2 or 4 points – 2 or 4 points

Analog Output – Optional Optional – – – –

Power Input AC / DC AC / DC AC / DC AC / DC AC / DC DC AC / DC

Mounting Direction Vertical / Horizontal Vertical / Horizontal Vertical Vertical / Horizontal Vertical Vertical / Horizontal Vertical

Dimensions W36 × H144 × D103 mm(1.42” × 5.67” × 4.06”)

W36 × H144 × D103 mm(1.42” × 5.67” × 4.06”)

W36 × H144 × D103 mm (1.42” × 5.67” × 4.06”)

W36 × H144 × D103 mm(1.42” × 5.67” × 4.06”)

W36 × H144 × D103 mm(1.42” × 5.67” × 4.06”)

W18 × H72 × D118 mm (0.71” × 2.83” × 4.65”)

W96 × H96 × D116 mm (3.78” × 3.78” × 4.61”)

Degree of Protection IP65 front cover IP65 front cover IP65 front cover IP65 front cover IP65 front cover – –

Standards & Approvals CE CE CE CE CE – –

48NV 48NAVx 48NDVx 48NAx 48NDx 48SV 49AV2

n Bargraph IndicatorDC Input 48NV – – – – 48SV –

n Bargraph Indicating AlarmDC Input – 48NAV – – – – –

Transmitter Output – 48NAVA – – – – –2-wire Transmitter Excitation – 48NAVD – – – – –

Thermocouple Input – – – 48NAT – – –RTD Input – – – 48NAR – – –

Potentiometer Input – – – 48NAM – – –

n Bargraph Indicating Alarm (with 4-digit digital meter)DC Input – – 48NDV – – – 49AV2

Transmitter Output – – 48NDVA – – – –2-wire Transmitter Excitation – – 48NDVD – – – –

Thermocouple Input – – – – 48NDT – –RTD Input – – – – 48NDR – –

Potentiometer Input – – – – 48NDM – –

Indicators Products Selection Guide

Page 7: A Four-wire Signal Conditioners Product Selection Guide ... · Four-wire Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators Limit Alarms Gateway, Remote

D

112

Bargraph Indicators

Digital Panel Meters

6DV Series

43 Series

Four-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors Lightning Surge Protectors

Indi

cato

rs

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1

D

Bargraph Indicators

Digital Panel Meters

6DV Series

43 Series

Four-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors

Lightning Surge Protectors

Indi

cato

rs

113Specifications are subject to change without notice.ISP1-1

Indicators Products Selection Guide

IndicatorsProduct Selection Guide

IndicatorsProduct Selection Guide

LCD Display 47D Series

LED Display 47L Series

46 Series

43DV1

Loop Powered 6DV/6DVI

Loop Powered 6DV-B/6DVI-B

Loop Powered 43AL

Loop Powered 43AL-B

P.122 P.123 P.132 P.130 P.130 P.132 P.132

Display 5 1/2 digitsRed / Green LCD

4 or 4 1/2 digits Red, Orange, Green, Bluegreen, Blue,

White LED(47LYV: Red/Orange only)

4 digitsRed / Green LED

3 1/2 digitsRed LED

4 digitsRed LED

4 digitsRed LED

3 1/2 digitsRed LED

3 1/2 digitsRed LED

Connection M3 screw terminal / Terminal block / 50-pin connector M3 screw terminal M3 screw terminal Connector

(leadwires soldered) Terminal block Terminal block Terminal block Terminal block

Scaling Yes Yes – Yes 4 – 20mA DC 4 – 20mA DC 4 – 20mA DC 4 – 20mA DC

Direct Sensor Input Yes Yes – – – – – –

Alarm Output Optional, 2 or 4 points Optional, 2 or 4 points Optional, 2 or 4 points – – – – –

BCD Output Optional – Optional – – – – –

Network Interface Optional, RS-485 / Modbus RTU – Optional – – – – –

Analog Output Optional Optional Optional – – – – –

Power Input AC / DC AC / DC AC / DC DC None None None None

Dimensions W96 × H48 × D98.5 mm(3.78” × 1.89” × 3.88”)

W96 × H48 × D98.5 mm(3.78” × 1.89” × 3.88”)

W102.5 × H48 × D104 mm(4.04” × 1.89” × 4.09”)

W48 × H24 × D72 mm(1.89” × 0.94” × 2.83”) 70 (2.76”) dia. 110 (4.33”) dia. W48 × H24 × D40 mm

(1.89” × 0.94” × 1.57”) 110 (4.33”) dia.

Degree of Protection IP66 front panel IP66 front panel – – – – – –

Standards & Approvals – CE – – CE / ATEX / FM CE / ATEX / FM CE / UL CE / ATEX / FM

47D Series 47L Series 46 Series 43DV1 6DV Series 6DV-B Series 43AL 43AL-B

DC Input (indicator only) – 47LYV 46DL2 43DV1 – – 43AL –

DC Input (indicator only / intrinsically safe) – – – – 6DV, 6DVI – – –

DC Input (indicator only / explosion-proof) – – – – – 6DV-B, 6DVI-B – 43AL-B

DC Input 47DV 47LV 46DV2 – – – – –Thermocouple Input 47DT 47LT – – – – – –

RTD Input 47DR 47LR – – – – – –Potentiometer Input 47DM 47LM – – – – – –

AC Input – 47LAC – – – – – –Strain Gauge Input – 47LLC – – – – – –

VT Input – 47LPT – – – – – –CT Input – 47LCT – – – – – –

Frequency Input – 47LPA, 47LHZ, 47LPQ – – – – – –

Indicators Products Selection Guide

Page 8: A Four-wire Signal Conditioners Product Selection Guide ... · Four-wire Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators Limit Alarms Gateway, Remote

E

136

Four-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors Lightning Surge Protectors

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1

Limit Alarms Product Selection Guide

Limit AlarmsProduct Selection Guide

EFour-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors

Lightning Surge Protectors

137

Limit Alarms Product Selection Guide

Limit AlarmsProduct Selection Guide

Specifications are subject to change without notice.ISP1-1

Digital Adjustments AS4 Series

LCD Display M7E-UNIT Series

Extra DC Output AE-UNIT Series

Rotary Switch Adj. AL-UNIT Series

Potentiometer Adj. A-UNIT Series

M-PAC Series

Construction Plug-in Plug-in Plug-in Plug-in Plug-in Plug-inConnection M3.5 screw terminal M3 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal

Isolation Input to output to power Input to output to power Input to DC output to relay output to power Input to output to power Input to output to power Input to output to power

Dielectric Strength 2000V AC 2000V AC 2000V AC 2000V AC 2000V AC 1000V AC

Input Range Selectability Front key programming Front control buttons or PC software Specified when ordering Specified when ordering Specified when ordering Specified when ordering

No. of Alarm Point 2, 4 2, 4 2 2 2 1 or 2Relay Form Dual SPDT or Quad NO or NC Dual SPDT or Quad NO or NC SPDT SPDT SPDT SPDT or DPDT

Alarm Setting Front key programming Front control buttons or PC software Thumbwheel switches 10-position rotary switches 270°-turn screwdrivers Three-turn screwdrivers

Alarm Setpoint 0 – 100% 0 – 100% 0 – 99% 0 – 99% 0 – 100% 0 – 100%Deadband (Hysteresis) Adj. FS FS 9% – 1 – 100% 1 – 100%

Latching Output Yes Yes – – – YesSetpoint Accuracy ±0.1% FS ±0.1% FS ±0.5% ±0.5% ±0.5% ±0.2%

Alarm Test – Yes – – – –DC Output – – Yes – – Optional

Power Input AC / DC AC / DC AC / DC AC / DC AC / DC AC / DC

Operating Temperature -5 to +55°C (23 to 131°F)

-5 to +55°C (23 to 131°F)

-5 to +55°C (23 to 131°F)

-5 to +60°C (23 to 140°F)

-5 to +60°C (23 to 140°F)

-5 to +60°C (23 to 140°F)

Mounting Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface (DIN rail available for 11-pin base)

Dimensions W50 × H80 × D132 mm(1.97” × 3.15” × 5.20”)

W29.5 × H83 × D124 mm(1.16” × 3.27” × 4.88”)

W72 × H80 × D132 mm (2.83” × 3.15” × 5.20”)

W50 × H80 × D132 mm (1.97” × 3.15” × 5.20”)

W50 × H80 × D132 mm (1.97” × 3.15” × 5.20”)

W50 × H80 × D132 mm(1.97” × 3.15” × 5.20”)

W80 × H101 × D136 mm (3.15” × 3.98” × 5.35”)

Standards & Approvals CE / UL / C-UL CE – – – –

AS4 Series M7E-UNIT AE-UNIT AL-UNIT A-UNIT M-PAC

DC Input AS4V M7EASV AEV,AEAD (two-input addition) ALV ACV MP1000

Thermocouple Input AS4T – AET ALT ATC MP1200RTD Input AS4R – AER ALR ARB MP1400

Potentiometer Input AS4M – AEM ALM APOT MP1800Two-wire Transmitter – M7EASDY AEDY, AEDN ALDY, ALDN ADY, ADN MP1100Strain Gauge Input AS4LC – – – – –

AC Input – – AETG, AEAC ALTG, ALAC ATG, AAC MP1600PT Input – – AEPT ALPT APTA, APTE –CT Input AS4CT – AECT ALCT ACTA, ACTE –

Frequency Input – – AESP ALSP ASP MP1700Others – – – ALNR (Angle Sensor) ANR (Angle Sensor) –

Front View

L1

L2

L3

L4ALARM

DATA

ITEM

DATAITEM

ITEM No. Display

DATA UP-DOWN KeysITEM No. UP-DOWN Keys

MonitorLEDs

DATA Display

LCD Display

Mode ButtonSet ButtonPC ConfiguratorJack

Up ButtonDown Button Up

Down

Mode

Set

Hysteresis (Deadband)Adj. Thumbwheel SW

Setpoint Adj.Thumbwheel SW

Monitor LED

Monitor LEDHysteresis (Deadband)Adj. Thumbwheel SW

• OUTPUT 2

• OUTPUT 1

Setpoint Adj.Thumbwheel SW

9 99

9 99

Span Adj.Zero Adj.

No.1 SetpointRotary SW (x10%)No.1 SetpointRotary SW (x1%)No.2 SetpointRotary SW (x10%)No.2 SetpointRotary SW (x1%)

No.1 LED

No.2 LED

No.1 LED

No.1 Hysteresis (Deadband) Adj.No.2 Hysteresis (Deadband) Adj.

No.2 LED

No.1 Setpoint Adj.

No.2 Setpoint Adj.

Zero Adj.

Span Adj.No.1 LED

No.1 Hysteresis (Deadband) Adj.No.2 Hysteresis (Deadband) Adj.

No.2 LED

No.1 Setpoint Adj.

No.2 Setpoint Adj.

Zero Adj.

Span Adj.

Page 9: A Four-wire Signal Conditioners Product Selection Guide ... · Four-wire Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators Limit Alarms Gateway, Remote

E

138

Four-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors Lightning Surge Protectors

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1

Limit Alarms Product Selection Guide

Limit AlarmsProduct Selection Guide

EFour-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors

Lightning Surge Protectors

139

Limit Alarms Product Selection Guide

Limit AlarmsProduct Selection Guide

Specifications are subject to change without notice.ISP1-1

n Digital Adjustments n Dial/Potentiometer Adjustments n Thumbwheel Switch Adjustments

MSEF M6SXAS, M6NXAS, M6DXAS KSE L4AS ASD1 KSED

Construction Plug-in Ultra-slim Plug-in Discrete box; terminal access at the front Plug-in Plug-in

Connection M3.5 screw terminal Tension-clamp, M3 screw terminal, Euro terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminalIsolation Input to output to power Input to output to power Input to output to power Input to output to power Input to output to power Input to output to power

Dielectric Strength 2000V AC 2000V AC 2000V AC 2000V AC 2000V AC 2000V ACInput Type DC input DC input DC input DC input DC input DC input

Input Range Selectability Front control buttons Specified when ordering or PC programming Specified when ordering Specified when ordering Specified when ordering Specified when ordering

No. of Alarm Point 2 1 1, 2 2, 4 2 2Relay Form SPDT SPDT SPDT SPDT SPDT SPDT

Alarm Setting Front control buttons PC software Dials Single-turn screwdrivers or dials Thumbwheel switches Thumbwheel switchesAlarm Setpoint -14 to +113.5% -2 to +102% -15 to +120% -15 to +115% 0 – 99% 0 – 99%

Deadband (Hysteresis) Adj. 0.5 – 15% 0 – 99.9999% – – 14% –Latching Output Yes – – – Yes –

Setpoint Accuracy ±0.5% ±0.05% FS ±0.3% ±0.3% ±0.5% ±0.5%Alarm Test – Yes – – – –DC Output – – – – – –

Power Input AC / DC DC AC AC / DC AC AC

Operating Temperature -5 to +55°C (23 to 131°F)

-20 to +55°C (-4 to +131°F)

-5 to +55°C (23 to 131°F)

-5 to +55°C (23 to 131°F)

-5 to +60°C (23 to 140°F)

-5 to +55°C (23 to 131°F)

Mounting Surface or DIN rail DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail

Dimensions W50 × H80 × D136 mm (1.97” × 3.15” × 5.35”)

M6D/S: W5.9 × H94 × D102 mm (0.23” × 3.70” × 4.02”)

M6N: W7.5 × H102 × D102 mm (0.30” × 4.02” × 4.02”)

KSE-x1: W50 × H80 × D136 mm (1.97” × 3.15” × 5.35”) KSE-x2: W50 × H80 × D145 mm (1.97” × 3.15” × 5.71”)

W75 × H80 × D112 mm (2.95” × 3.15” × 4.41”)

D126 mm (4.96”) with dial adjustments

W50 × H80 × D132 mm (1.97” × 3.15” × 5.20”)

W50 × H80 × D132 mm(1.97” × 3.15” × 5.20”)

Standards & Approvals CE / UL / C-UL CE CE – CE / UL / C-UL CE / UL / C-UL

Front View

Monitor LED•Output 1

Setpoint Adj.9 9

Setpoint Adj.•Output 2

9 9

Monitor LED

Deadband & Latching Control

Deadband & Latching Control

Hi Monitor LED

Hi Setpoint Adj.

Lo Setpoint Adj.

Lo Monitor LED

9 9

9 9

MODE Selector

Digital Display

DOWN ControlUP Control

L1 MonitorLED

L2 MonitorLED Status Indicator LED

Alarm Monitor LED

Configurator Jack

Power LEDHi Monitor LED

Hi Setpoint Adj. Dial

100

50 %

0

■ KSE-x1

Lo Monitor LED

Hi Setpoint Adj. Dial

Lo Setpoint Adj. Dial

Hi Monitor LED

100

50 %

SET1

0100

50 %

SET20

■ KSE-x2

1 2 3 4

Monitor LED

Setpoint Adj.

■ Dial Adjustments

1 2 3 4

Monitor LED

Setpoint Adj.

■ Screwdriver Adjustments

1 2 3 4

Monitor LED

Setpoint Adj.

■ Dial Adjustments

1 2 3 4

Monitor LED

Setpoint Adj.

■ Screwdriver Adjustments

Page 10: A Four-wire Signal Conditioners Product Selection Guide ... · Four-wire Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators Limit Alarms Gateway, Remote

E

140

Four-wire Signal Conditioners

Two-wire Signal Conditioners

Power Transducers

Indicators

Limit Alarms

Gateway,Remote I/O

Paperless RecordingSystem

PC Recorder

Electronic Actuators& Position Sensors Lightning Surge Protectors

Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1

Limit Alarms Product Selection Guide

Limit AlarmsProduct Selection Guide

n Thumbwheel Switch Adjustments n Deviation Alarm

M2SED M2AS M2AS1 AYDV

Construction Plug-in Plug-in Plug-in Plug-inConnection M3 screw terminal M3 screw terminal M3 screw terminal M3.5 screw terminal

Isolation Input to output to power Input to output to power Input to output to power Input to output to powerDielectric Strength 2000V AC 2000V AC 2000V AC 2000V AC

Input Type DC input DC input DC input DC inputInput Range Selectability Specified when ordering Specified when ordering Specified when ordering Specified when ordering

No. of Alarm Point 2 1 1 2Relay Form SPDT DPDT SPDT SPDT

Alarm Setting Thumbwheel switches Thumbwheel switches Thumbwheel switches Multi-turn screwdriversAlarm Setpoint 0 – 99% 0 – 99% 0 – 99% -50 to +50%

Deadband (Hysteresis) Adj. – FS FS –Latching Output – Yes Yes –

Setpoint Accuracy ±0.5% ±0.5% ±0.5% ±0.5%Alarm Test – – – –DC Output – – – –

Power Input AC / DC AC / DC AC / DC AC / DC

Operating Temperature -5 to +55°C (23 to 131°F)

-5 to +55°C (23 to 131°F)

-5 to +55°C (23 to 131°F)

-5 to +60°C (23 to 140°F)

Mounting Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail

Dimensions W29.5 × H76 × D124 mm (1.16” × 2.99” × 4.88”)

W29.5 × H76 × D124 mm (1.16” × 2.99” × 4.88”)

W23 × H76 × D124 mm (0.91” × 2.99” × 4.88”)

W50 × H80 × D132 mm (1.97” × 3.15” × 5.20”)

Standards & Approvals CE / UL / C-UL CE CE –

Front View Setpoint 1 Adj. & LED

Setpoint 2 Adj. & LED

Setpoint 2 Monitor

Setpoint 1 Monitor

COM.

Output 1 Setpoint Adj.

Output 2 Setpoint Adj.

Output 1 Monitor LED

Output 2 Monitor LED

9 9

9 9

OutputSetpoint Adj.

Deadband Adj.

OutputMonitor LED

Reset Control

9 9

9 9

OutputSetpoint Adj.

Deadband Adj.

OutputMonitor LED

Reset Control

9 9

9 9