A N DY Status First commissioning with colliding beams (p +p at s=500 GeV). L.C.Bland, for AnDY 1 February 2011 Time Meeting, BNL. Schematic of detector for Run-11. Equipment in place: HCal is two existing 9x12 modules from E864 (NIM406,227) - PowerPoint PPT PresentationTRANSCRIPT
ANDY StatusFirst commissioning with colliding beams (p+p at s=500 GeV)
L.C.Bland, for AnDY1 February 2011Time Meeting, BNL
04/22/23 2
Schematic of detector for Run-11Equipment in place:• HCal is two existing 9x12 modules from
E864 (NIM406,227)
• ECal are two small lead-glass modules from BigCal at JLab
• BBC (from PHOBOS) and ZDC
• Preshower is newly constructed scintillator arrays
Goals:• Establish impact of 3IR operation on
PHENIX/STAR luminosity
• Calibrate HCal
• relative gain via cosmic-ray
• absolute energy scale via ,KS…
• Measure hadronic backgrounds to benchmark simulations
• Measure jet analyzing power (Lint~10 / pb, P=50%)
04/22/23 3
IP2 in January, 2011Run-11 Staging of ANDY
See http://hena.lbl.gov/IP2/Business/status/<date> for pictures of progress
Left/right symmetric HCal
Left/right symmetric ECal
Left/right symmetric preshower
Trigger/DAQ electronics
Blue-facing BBC
Beryllium vacuum pipe
04/22/23 4
Commissioning• First data recorded on Weds. 26 January after fixing MVME 2306 and FPGA board (DSM)
• Timed-in beam-beam counter, ECal and HCal phototube signals to ADC
• Commissioned minimum-bias trigger
• Further commissioning on Thurs. 27 January
• HV scan of BBC for gain adjustments
• Align data pipeline timing for ZDC
• Timed-in ZDC, ZDC shower-maximum detector and preshower signals to ADC
• Further commissioning on Sun. 30 January
• Identify reversed logic issue for time-to-amplitude converters (partially fixed on 31 Jan 15-minute access)
• Commission elog, database recording
So far, no impact of collisions at IP2 on IP6,8
04/22/23 5
Event ReconstructionReconstruct 200K minimum-bias events as seen in beam-left ECal via
• Clustering
• Shower-shape analysis
50 MeV/count for all detectors
Fixed vertex position used (TAC issue)
Epair>12 GeV, |E1-E2|/Epair < 0.8
Neutral pion reconstruction from ECal will be part of HCal calibration
Reconstructions concurrent with data acquisition provide critical feedback to experiment
04/22/23 6
Issuesshould be resolved during 20110202 access
• Recover event hit-timing information from BBC detectors
• Single-channel issues
• Increase monitoring feedback to MCR
• … and a long list of small tasks
• After access,
• adjust gains for ECal and selected HCal (mostly good from cosmic-rays)
• start commissioning triggers on HCal, ECal and ZDC
We are ~1 week from physics-quality data