a proof-of principle study of 2d optical streaking for ultra-short e-beam diagnostics using...
TRANSCRIPT
![Page 1: A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization electrons & circular polarized laser Lanfa Wang](https://reader033.vdocument.in/reader033/viewer/2022052603/56649cdb5503460f949a5b6c/html5/thumbnails/1.jpg)
1
A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization
electrons & circular polarized laser
Lanfa WangYuantao Ding and Zhirong Huang
LCLS II Physics Meeting, 5/25/2011
![Page 2: A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization electrons & circular polarized laser Lanfa Wang](https://reader033.vdocument.in/reader033/viewer/2022052603/56649cdb5503460f949a5b6c/html5/thumbnails/2.jpg)
2
From RF (cm) to optical (m) streaking
e-
sz
2.44 m
bd bsD 90°
V(t) sy
RF‘streak’
S-band
LCLS S-band RF deflector (λS_RF = 10cm) gives resolution ~ 10fs; For short e-beam, λRF >> σz, the streaking is not efficient; X-band RF deflector helps(λX_RF = 2.6cm), one after undulator is planned; How about going to optical wavelength(um)?
• > 10 um wavelength;• typically a wiggler is required for interaction with high-E e-beam;• the required laser power ~10s GW.• synchronization is a problem.
We are proposing a new method to overcome the disadvantages (power & synchronization) using a circularly-polarized 10 um laser.
![Page 3: A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization electrons & circular polarized laser Lanfa Wang](https://reader033.vdocument.in/reader033/viewer/2022052603/56649cdb5503460f949a5b6c/html5/thumbnails/3.jpg)
3
THz-driven x-ray streak camera
Nature Photonics, 3, 523. Both x-ray and THz are generated from the same e-beam, phase locked; X-ray and THz co-propagate at the same direction; Photoelectrons are modulated by THz and detected by TOF detector. Very similar to the RF zero-phasing method for e-beam diagnostics.
Phil Bucksbaum suggested to us long time ago about streaking the ionized electrons from high-E electron gas interaction for high-E electron bunch diagnostics. Advantage: The required laser power is lowerA lot of issued to consider, and, most difficult problem is synchronization……
![Page 4: A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization electrons & circular polarized laser Lanfa Wang](https://reader033.vdocument.in/reader033/viewer/2022052603/56649cdb5503460f949a5b6c/html5/thumbnails/4.jpg)
4
synchronization problemLinear polarized Laser, the momentum kick due to the laser is
))(sin()(
)( 0 zzeE
zPL
xx
The whole circle is just one rf period calibration; No Phasing problem.
Deflecting from circular (RF) mode
D. Alesini, DIPAC 09.
Similar as the deflecting cavity
The phase jitter causes the difficulty in the measurement!
![Page 5: A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization electrons & circular polarized laser Lanfa Wang](https://reader033.vdocument.in/reader033/viewer/2022052603/56649cdb5503460f949a5b6c/html5/thumbnails/5.jpg)
5
2D streaking with ionization electrons & circularly-polarized laser
……
…..
……
…..
……
….
-10kV
(2) circularly-polarized laser
(1) gas nozzle
(3) DC field
(4) screen)
Beam ionization
High energy bunch
Laser beam
Ionization electronbunch
![Page 6: A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization electrons & circular polarized laser Lanfa Wang](https://reader033.vdocument.in/reader033/viewer/2022052603/56649cdb5503460f949a5b6c/html5/thumbnails/6.jpg)
6
Interaction of Laser field with ionization electron beam
-1.5 -1 -0.5 0 0.5 1 1.5-20
-15
-10
-5
0
5
10
15
20
t ()
EL
(G
V/m
)(G
V/m
/ps
)
FieldField Gradient
yLLL tttE
tE eex )sin()cos(1
)()(
2
0
With ellipticity . =0 for linear polarized laser and =1 for circular polarized laser
Polarized laser
)(0 )()( zi
L
ezeE
z
P
Z
Zi
Ionization electron beamIonization electron beam(Low energy beam, plasma electron):
It has the same profile as the high energy beamIt doesn’t move longitudinally (very slow), so the laser beam passes the whole low energy and modulates its energy(momentum) according to the electron birth time (z) ;
0/)( czz L
If E(Z) is constant during the short period of bunch pulse, then all electrons receive the same amount transverse kicker with angle linear dependence on their position in z
For a circular polarized laser, the momentum kick due to the laser is
![Page 7: A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization electrons & circular polarized laser Lanfa Wang](https://reader033.vdocument.in/reader033/viewer/2022052603/56649cdb5503460f949a5b6c/html5/thumbnails/7.jpg)
7
Low energy beam on the screen
)(0 )()( zi
L
ezeE
z
P
Z
Zi
Ionization electron beamIonization electron beam(Low energy beam):
The low energy beam is accelerated (longitudinally, Beam direction) by the DC field to the screen
0/)( czz L
On the screen, the low energy electrons form a circle (arc) because:
The kicker strength from the circular laser is constant (approximately);And the angle linearly depends electron birth time(z)
a
H T
(z)
V
H
T
a
R=V*t
The radius of the circle depends on the laser field strength and drift time to the screen
R=tThe profile of the low energy electrons is translated to the angular distribution on the screen
00 2/)(
LL
zcz
2
LhBunchlengt
![Page 8: A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization electrons & circular polarized laser Lanfa Wang](https://reader033.vdocument.in/reader033/viewer/2022052603/56649cdb5503460f949a5b6c/html5/thumbnails/8.jpg)
8
Parameters used in simulation
Gas: Helium, pressure=1E-4Torr, assuming ionization length=1mmThere is no field ionization;Neutralization factor=0.4%, consider ionization length,the density of low energy electrons is much lower (by a factor of 1.0e5) than the density of high energy beam
Laser wave length 10mThe rms size of laser >=3 times of the beam rms sizeLaser FWHM 500fsLaser power: varies
DC voltage ~ keVRequired electron density ~ 3e9/mm2
![Page 9: A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization electrons & circular polarized laser Lanfa Wang](https://reader033.vdocument.in/reader033/viewer/2022052603/56649cdb5503460f949a5b6c/html5/thumbnails/9.jpg)
9
Effect of laser phase
0
90o180o
270o
![Page 10: A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization electrons & circular polarized laser Lanfa Wang](https://reader033.vdocument.in/reader033/viewer/2022052603/56649cdb5503460f949a5b6c/html5/thumbnails/10.jpg)
10
On the screen: Example for 0.5/1 m bunch (Laser field only)
100 200 300 400 500 6000
0.2
0.4
0.6
0.8
1
1.2
1.4
angle(degree)
Ds
trib
uti
on
after shift
100 200 300 400 500 6000
0.1
0.2
0.3
0.4
0.5
0.6
0.7
angle(degree)
Ds
trib
uti
on
after shift
![Page 11: A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization electrons & circular polarized laser Lanfa Wang](https://reader033.vdocument.in/reader033/viewer/2022052603/56649cdb5503460f949a5b6c/html5/thumbnails/11.jpg)
11
Other effects may spoil the distribution
……
…..
……
…..
……
….
-10kV
(2) circularly-polarized laser
(1) gas nozzle
(3) DC field
(4) screen)
Z
Zi
•High energy beam field•Field of Plasma electrons and ions
![Page 12: A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization electrons & circular polarized laser Lanfa Wang](https://reader033.vdocument.in/reader033/viewer/2022052603/56649cdb5503460f949a5b6c/html5/thumbnails/12.jpg)
12
Effect of High energy beam field
0 200 400 600 800 1000 12000
0.005
0.01
0.015
0.02
0.025
0.03
0.035
0.04
0.045
energy (eV) D
str
ibu
tio
n-15 -10 -5 0 5 10 150
2
4
6
8
10
12
14x 10
9
t (fs)
Er (
V/m
)
20pC bunch1 m bunch lengthSigma_r=5 m
E-field of high energy beamEnergy distribution of low energy electrons without laser beam
![Page 13: A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization electrons & circular polarized laser Lanfa Wang](https://reader033.vdocument.in/reader033/viewer/2022052603/56649cdb5503460f949a5b6c/html5/thumbnails/13.jpg)
13
1m bunch; 10pC; r= 5m, peak laser field 19GV/m(0.63GW), peak beam field=7GV/m
100 200 300 400 500 6000
0.1
0.2
0.3
0.4
0.5
0.6
0.7
angle(degree)
Ds
trib
uti
on
after shift
w.o. beam effect
head
tail
10pc bunch
100 200 300 400 500 6000
0.1
0.2
0.3
0.4
0.5
0.6
0.7
angle(degree)
Ds
trib
uti
on
after shift
w.o. beam effect
1m bunch; 20pC; r= 5m, peak laser field 38GV/m (1.25GW), peak beam field=13GV/m
20pc bunch
![Page 14: A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization electrons & circular polarized laser Lanfa Wang](https://reader033.vdocument.in/reader033/viewer/2022052603/56649cdb5503460f949a5b6c/html5/thumbnails/14.jpg)
14
Effect of laser power(r=5m)
100 200 300 400 500 6000
0.1
0.2
0.3
0.4
0.5
0.6
0.7
angle(degree)
Ds
trib
uti
on
after shift
w.o. beam effect
100 200 300 400 500 6000
0.1
0.2
0.3
0.4
0.5
0.6
0.7
angle(degree)
Ds
trib
uti
on
after shift
w.o. beam effectPL=0.9GW
PL=0.45GW
![Page 15: A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization electrons & circular polarized laser Lanfa Wang](https://reader033.vdocument.in/reader033/viewer/2022052603/56649cdb5503460f949a5b6c/html5/thumbnails/15.jpg)
15
Laser power effect (r=5m)vacuum, L=1mm, P=1e-4Torr(Helium) Neutralization factor=0.4%
PL=1.2GW
PL=1.5GW
100 200 300 400 500 6000
0.1
0.2
0.3
0.4
0.5
0.6
0.7
angle(degree)
Ds
trib
uti
on
w.o. beam effect
100 200 300 400 500 6000
0.1
0.2
0.3
0.4
0.5
0.6
0.7
angle(degree)
Ds
trib
uti
on
w.o. beam effect
PL=1.8GW
100 200 300 400 500 6000
0.1
0.2
0.3
0.4
0.5
0.6
0.7
angle(degree)
Ds
trib
uti
on
w.o. beam effect
![Page 16: A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization electrons & circular polarized laser Lanfa Wang](https://reader033.vdocument.in/reader033/viewer/2022052603/56649cdb5503460f949a5b6c/html5/thumbnails/16.jpg)
16
beam size effect (L=0.2m, P=1e-4Torr)
100 200 300 400 500 6000
0.1
0.2
0.3
0.4
0.5
0.6
0.7
angle(degree)
Ds
trib
uti
on
after shift
w.o. beam effect
r=10m, PL=1.8GW
100 200 300 400 500 6000
0.1
0.2
0.3
0.4
0.5
0.6
0.7
angle(degree)
Ds
trib
uti
on
after shift
w.o. beam effect
r=15m, PL=5.0GW
RL=7mm
RL=10mm
sigr15fla25w090
sigr10fla20w060
![Page 17: A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization electrons & circular polarized laser Lanfa Wang](https://reader033.vdocument.in/reader033/viewer/2022052603/56649cdb5503460f949a5b6c/html5/thumbnails/17.jpg)
17
Effect of laser Power & beam size
100 200 300 400 500 6000
0.1
0.2
0.3
0.4
0.5
0.6
0.7
angle(degree)
Ds
trib
uti
on
after shift
w.o. beam effect
100 200 300 400 500 6000
0.1
0.2
0.3
0.4
0.5
0.6
0.7
angle(degree)
Ds
trib
uti
on
after shift
w.o. beam effect
100 200 300 400 500 6000
0.1
0.2
0.3
0.4
0.5
0.6
0.7
angle(degree)
Ds
trib
uti
on
w.o. beam effect
PL=1.2GWPL=0.4GW PL=0.9GW
100 200 300 400 500 6000
0.1
0.2
0.3
0.4
0.5
0.6
0.7
angle(degree)
Ds
trib
uti
on
P=0.9GW
w.o. beam effect
100 200 300 400 500 6000
0.1
0.2
0.3
0.4
0.5
0.6
0.7
angle(degree)
Ds
trib
uti
on
after shift
w.o. beam effect
PL=0.9GWPL=1.8GW
r=5m
r=10m
![Page 18: A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization electrons & circular polarized laser Lanfa Wang](https://reader033.vdocument.in/reader033/viewer/2022052603/56649cdb5503460f949a5b6c/html5/thumbnails/18.jpg)
18
Similar idea may work for x-ray pulse measurement
……
…..
……
…..
……
….
-10kV
(2) circularly-polarized laser
(1) gas nozzle
Laser wavelength >~ xray wavelength
(3) DC field
(4) screen)
Xray- ionization
![Page 19: A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization electrons & circular polarized laser Lanfa Wang](https://reader033.vdocument.in/reader033/viewer/2022052603/56649cdb5503460f949a5b6c/html5/thumbnails/19.jpg)
19
Summary
Circularly-polarized laser, no phase synchronization problem;Interaction in vacuum, no wiggler needed; Streaking the ionized low-E beam, required laser power is lower;
Pros
ConsComplexity : Involved many dynamics
Preliminary conclusion:This method looks promising based on the preliminary studies.Required laser power depends on the beam: 1GW for r=5mGas pressure: 1.0e-4 Torr (mm)Space charge of low energy particles is not included
![Page 20: A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization electrons & circular polarized laser Lanfa Wang](https://reader033.vdocument.in/reader033/viewer/2022052603/56649cdb5503460f949a5b6c/html5/thumbnails/20.jpg)
20
AcknowledgmentThanks very helpful discussions with Eric Colby, Mark Hogan and Weiming An (UCLA)
![Page 21: A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization electrons & circular polarized laser Lanfa Wang](https://reader033.vdocument.in/reader033/viewer/2022052603/56649cdb5503460f949a5b6c/html5/thumbnails/21.jpg)
21
Linear polarized x-ray
(z) V
P0
Need realistic model of the X-ray ionization
Assuming ionized electrons are emitted only in polarization direction (NOT accurate model!)
![Page 22: A Proof-of Principle Study of 2D optical streaking for ultra-short e-beam diagnostics using ionization electrons & circular polarized laser Lanfa Wang](https://reader033.vdocument.in/reader033/viewer/2022052603/56649cdb5503460f949a5b6c/html5/thumbnails/22.jpg)
22