a protocol for simple, rapid, and direct detection of sars

7
Copyright © 2020 The Authors; exclusive licensee Bio-protocol LLC. 1 www.bio-protocol.org/e3789 Bio-protocol 10(20): e3789. DOI:10.21769/BioProtoc.3789 A Protocol for Simple, Rapid, and Direct Detection of SARS-CoV-2 from clinical samples, using Reverse Transcribed Loop-Mediated Isothermal Amplification (RT-LAMP) Rawi Naddaf 1, # , Nadav Ben-Assa 1, # , Tal Gefen 1 , Tal Capucha 1, 2 , Haitham Hajjo 1, 3, 4 , Noa Mandelbaum 1 , Lilach Elbaum 1 , Shai Kaplan 5 , Assaf Rotem 6 , Michal Chowers 7, 8 , Moran Szwarcwort- Cohen 9 , Mical Paul 10 and Naama Geva-Zatorsky 1, 11, * 1 Department of Cell Biology and Cancer Science, Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Technion Integrated Cancer Center (TICC), Haifa, 3525433, Israel; 2 Oral and Maxillofacial Surgery Department, Rambam Medical Care Center, Haifa, 3525433, Israel; 3 Department of Immunology, Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel; 4 Department of Neuroscience, Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel; 5 Robiotec ltd 9 Aharonwitz st. Rehovot, 7634709, Israel; 6 47 Bow Rd, Newton MA 02459, USA; 7 Infectious Diseases Unit, Meir Medical Center, Kfar Saba, Israel; 8 Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel; 9 Virology Laboratory, Rambam Health Care Campus, Haifa, Israel; 10 Division of Infectious Diseases, Rambam Health Care Center and Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel; 11 Canadian Institute for Advanced Research (CIFAR) Azrieli Global Scholar, MaRS Centre, West Tower 661 University Ave., Suite 505 Toronto, ON M5G 1M1, Canada # Contributed equally to this work *For correspondence: [email protected] [Abstract] SARS-CoV-2 has quickly spread all around the globe causing illness and wide damages. Most countries were unprepared for such a rapid spread and crisis. This led to various strategies for effective control of the new pandemic. A key aspect in all countries was to effectively test the population for the virus. Most countries chose a lockdown strategy in which many workplaces and activities are completely closed, leading to substantial economy costs. Here, we present a protocol we recently developed that allows rapid and simple detection of SARS-CoV-2 for the large population, eliminating costs and involvement of professional teams and laboratories. This protocol is based on Reverse Transcribed Loop-Mediated Isothermal Amplification (RT-LAMP). We tested this protocol directly on patient samples, both nasal and throat clinical swabs as well as saliva. Notably, this protocol is simple, cheap and can be easily applied to other pathogens as well. Keywords: SARS-CoV-2, Covid-19, RT-LAMP, Pandemic, Rapid molecular Detection, Colorimetric, Isothermal, Saliva. [Background] The Covid-19 pandemic, caused by the novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), is affecting large populations, and has been declared a pandemic by the World Health Organization (WHO). Please cite this article as: Naddaf et. al., (2020). A Protocol for Simple, Rapid, and Direct Detection of SARS-CoV-2 from clinical samples, using Reverse Transcribed Loop-Mediated Isothermal Amplification (RT-LAMP),Bio-protocol 10 (20): e3789. DOI: 10.21769/BioProtoc.3789.

Upload: others

Post on 23-May-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: A Protocol for Simple, Rapid, and Direct Detection of SARS

Copyright © 2020 The Authors; exclusive licensee Bio-protocol LLC. 1

www.bio-protocol.org/e3789 Bio-protocol 10(20): e3789. DOI:10.21769/BioProtoc.3789

A Protocol for Simple, Rapid, and Direct Detection of SARS-CoV-2 from clinical samples, using Reverse Transcribed Loop-Mediated Isothermal Amplification (RT-LAMP)

Rawi Naddaf1, #, Nadav Ben-Assa1, #, Tal Gefen1, Tal Capucha1, 2, Haitham Hajjo1, 3, 4, Noa Mandelbaum1, Lilach Elbaum1, Shai Kaplan5, Assaf Rotem6, Michal Chowers7, 8, Moran Szwarcwort-

Cohen9, Mical Paul10 and Naama Geva-Zatorsky1, 11, * 1Department of Cell Biology and Cancer Science, Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Technion Integrated Cancer Center (TICC), Haifa, 3525433, Israel; 2Oral and

Maxillofacial Surgery Department, Rambam Medical Care Center, Haifa, 3525433, Israel; 3Department of Immunology, Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel; 4Department of Neuroscience, Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel; 5Robiotec ltd 9 Aharonwitz st. Rehovot, 7634709, Israel; 647 Bow Rd, Newton MA 02459,

USA; 7Infectious Diseases Unit, Meir Medical Center, Kfar Saba, Israel; 8Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel; 9Virology Laboratory, Rambam Health Care Campus, Haifa, Israel; 10Division of Infectious Diseases, Rambam Health Care Center and Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel; 11Canadian Institute for Advanced Research

(CIFAR) Azrieli Global Scholar, MaRS Centre, West Tower 661 University Ave., Suite 505 Toronto, ON M5G 1M1, Canada #Contributed equally to this work *For correspondence: [email protected]

[Abstract] SARS-CoV-2 has quickly spread all around the globe causing illness and wide damages.

Most countries were unprepared for such a rapid spread and crisis. This led to various strategies for effective control of the new pandemic. A key aspect in all countries was to effectively test the population

for the virus. Most countries chose a lockdown strategy in which many workplaces and activities are completely closed, leading to substantial economy costs. Here, we present a protocol we recently

developed that allows rapid and simple detection of SARS-CoV-2 for the large population, eliminating costs and involvement of professional teams and laboratories. This protocol is based on Reverse

Transcribed Loop-Mediated Isothermal Amplification (RT-LAMP). We tested this protocol directly on patient samples, both nasal and throat clinical swabs as well as saliva. Notably, this protocol is simple,

cheap and can be easily applied to other pathogens as well. Keywords: SARS-CoV-2, Covid-19, RT-LAMP, Pandemic, Rapid molecular Detection, Colorimetric,

Isothermal, Saliva.

[Background] The Covid-19 pandemic, caused by the novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), is affecting large populations, and has been declared a pandemic by the

World Health Organization (WHO).

Please cite this article as: Naddaf et. al., (2020). A Protocol for Simple, Rapid, and Direct Detection of SARS-CoV-2 from clinical samples, using ReverseTranscribed Loop-Mediated Isothermal Amplification (RT-LAMP),Bio-protocol 10 (20): e3789. DOI: 10.21769/BioProtoc.3789.

Page 2: A Protocol for Simple, Rapid, and Direct Detection of SARS

Copyright © 2020 The Authors; exclusive licensee Bio-protocol LLC. 2

www.bio-protocol.org/e3789 Bio-protocol 10(20): e3789. DOI:10.21769/BioProtoc.3789

Mass surveillance of the population and quarantine proved to be effective strategies in dealing with

this crisis. The main key for detection is the reverse transcription quantitative polymerase chain reaction (RT-qPCR) test. While this test is effective, it requires professional experience both in sampling and in

performing the test. Furthermore, the reagents and lab equipment are expensive (Bruce et al., 2020). Altogether, these created a bottleneck for mass scale testing.

Fortunately, to date, alternative molecular biology methods can overcome such limitations. One of these methods is colorimetric Loop-Mediated Isothermal Amplification (LAMP) (Notomi et al., 2000).

LAMP is performed at a single and constant temperature (i.e., isothermal), and allows a one-step reverse transcription. Its results can be visualized by color change with the naked eye. This method is

cheap and requires little to no lab equipment (Wang et al., 2016; Yu et al., 2020; Zhang et al., 2020). It can be widely used in points of care such as the workplace and schools, which can increase the number

of tested subjects tremendously. We see this method as a surveillance tool to markedly increase the total number of tests per day and identify patients for further tests in hospital settings.

Here we present a protocol for applying one step reverse transcribed LAMP (RT-LAMP) detection method on clinical samples from nasal, throat swabs and from saliva. The primers we used were

previously designed by Zhang et al., 2020 on synthetic and purified RNA (Table 1). The protocol we present (Ben-Assa*, Naddaf* et al., 2020), while with these same primers, does not require RNA

purification steps and can be conducted directly on clinical samples. This protocol requires no professional experience and results can be obtained within an hour. The results of this protocol were

compared to the approved RNA purification and quantification RT-qPCR method at the Rambam Health Care Campus (RHCC) hospital. The downside of this method is its detection sensitivity, which is

considerably lower than the standard RT-qPCR method (Ben-Assa*, Naddaf* et al., 2020). Therefore, it is applicable for a large-scale surveillance tool rather than a replacement of the current gold-standard

detection method. While this protocol was validated on SARS-CoV-2, it can be adjusted to other pathogens too (bacteria or viruses).

Material and Reagents

1. Personal protective equipment (PPE) appropriate for working with SARS-CoV-2

2. 0.2 ml PCR tube strips (Labcon, catalogue number: LC 3927-550) 3. Pipette tips

4. WarmStart® Colorimetric LAMP 2x Master Mix (New England BioLabs Inc., catalog number: M1800) (aliquot and store at -20 °C)

5. Proteinase K (Seegene, catalog number: 744300.4.UC384, store at -20 °C) 6. Guanidine hydrochloride (Sigma, catalog number: G4505)

7. DNase RNase free water (Biological Industries, catalog number: 01-869-1B) 8. Primers for SARS-CoV-2 (Table 1) (Zhang et al., 2020)

9. Primers for pop7–positive internal processing and amplification control (Table 2) (Curtis et al., 2018)

Please cite this article as: Naddaf et. al., (2020). A Protocol for Simple, Rapid, and Direct Detection of SARS-CoV-2 from clinical samples, using ReverseTranscribed Loop-Mediated Isothermal Amplification (RT-LAMP),Bio-protocol 10 (20): e3789. DOI: 10.21769/BioProtoc.3789.

Page 3: A Protocol for Simple, Rapid, and Direct Detection of SARS

Copyright © 2020 The Authors; exclusive licensee Bio-protocol LLC. 3

www.bio-protocol.org/e3789 Bio-protocol 10(20): e3789. DOI:10.21769/BioProtoc.3789

10. Primer mix (see Recipes)

11. Proteinase K (see Recipes) 12. Guanidine hydrochloride (see Recipes)

Table 1. SARS-CoV-2 Primers for RT-LAMP

Primer Name Sequence

GeneN-A-F3 TGG CTA CTA CCG AAG AGC T

GeneN-A-B3 TGC AGC ATT GTT AGC AGG AT

GeneN-A-LF (Loop Forward) GGA CTG AGA TCT TTC ATT TTA CCG T

GeneN-A-LB (Loop Backward) ACT GAG GGA GCC TTG AAT ACA

GeneN-A-FIP (Forward Inner Primer) TCT GGC CCA GTT CCT AGG TAG TCC AGA CGA ATT CGT GGT GG

GeneN-A-BIP (Backward Inner Primer) AGA CGG CAT CAT ATG GGT TGC ACG GGT GCC AAT GTG ATC T

Table 2. RNaseP pop7 Primers for RT-LAMP–Positive Control

Primer Name Sequence

pop7-F3 TTG ATG AGC TGG AGC CA

pop7-B3 CAC CCT CAA TGC AGA GTC

pop7-LF (Loop Forward) ATG TGG ATG GCT GAG TTG TT

pop7-LB (Loop Backward) CAT GCT GAG TAC TGG ACC TC

pop7-FIP (Forward Inner Primer) GTG TGA CCC TGA AGA CTC GGT TTT AGC CAC TGA CTC GGA TC

pop7-BIP (Backward Inner Primer) CCT CCG TGA TAT GGC TCT TCG TTT TTT TCT TAC ATG GCT CTG GTC

Equipment

1. 1 µl-10 µl, 10 µl-50 µl, 20 µl-200 µl pipettes 2. PCR Thermocycler as heat source (Biometra, catalog number: T3000)

Procedure

A. Prepare primer mix. (see Recipes)

Prepare two mixes: (1) For SARS-Cov-2 test. (2) For pop7 positive internal processing and amplification control.

Please cite this article as: Naddaf et. al., (2020). A Protocol for Simple, Rapid, and Direct Detection of SARS-CoV-2 from clinical samples, using ReverseTranscribed Loop-Mediated Isothermal Amplification (RT-LAMP),Bio-protocol 10 (20): e3789. DOI: 10.21769/BioProtoc.3789.

Page 4: A Protocol for Simple, Rapid, and Direct Detection of SARS

Copyright © 2020 The Authors; exclusive licensee Bio-protocol LLC. 4

www.bio-protocol.org/e3789 Bio-protocol 10(20): e3789. DOI:10.21769/BioProtoc.3789

B. Sample lysis and preparation (see Figure 1A)

1. For saliva samples: Resuspend in 1 ml of DNase RNase free water (in the same container of the saliva sample). For throat/nasal swab samples: Use the standard universal transfer media

(UTM) for this test. 2. Add 5 µl of the sample (from Step B1) to a PCR tube containing 40 µl of DNase RNase free

water. 3. Include a non-template control. Add 5 µl DNase RNase free water instead of the sample.

4. Add 2 µl proteinase K (final concentration 1.22 mg/ml). 5. Incubate at room temperature for 15 min.

6. Incubate samples at 95 °C for 5 min in a PCR machine or any other heat source. Note: We have successfully used thermal cup and hot water.

7. Cool your sample down to room temperature.

C. RT-LAMP reaction (see Figure 1A) Prepare three mixes: (1) For SARS-CoV-2 test. (2) For pop7 gene as positive control. For each mix

use the relevant primers. (3) For non-template control (see Step B3) using the SARS-CoV-2 primers. 1. Prepare reaction:

LAMP mix 10 µl Primer mix 2 µl

Guanidine hydrochloride 1 µl Sample lysate (product of Procedure B) 7 µl

2. Incubate at 65 °C for 30-40 min. 3. Read results:

If the mix color changes from pink to yellow, the sample has tested positive (see Figure 1B). If the mix maintains its pink color, the sample has tested negative (see Figure 1B).

Please note that the results are binary as positive or negative. Only bright yellow results are considered positive. Pink is considered negative, and any other range or gradient of color is

considered negative. Positive control results were published at Ben-Assa*, Naddaf* et al., 2020 (Figure 3a).

Please cite this article as: Naddaf et. al., (2020). A Protocol for Simple, Rapid, and Direct Detection of SARS-CoV-2 from clinical samples, using ReverseTranscribed Loop-Mediated Isothermal Amplification (RT-LAMP),Bio-protocol 10 (20): e3789. DOI: 10.21769/BioProtoc.3789.

Page 5: A Protocol for Simple, Rapid, and Direct Detection of SARS

Copyright © 2020 The Authors; exclusive licensee Bio-protocol LLC. 5

www.bio-protocol.org/e3789 Bio-protocol 10(20): e3789. DOI:10.21769/BioProtoc.3789

Figure 1. Procedure and results of SARS-CoV-2 RT-LAMP detection test. A. An illustration of the steps of the protocol: this illustration summarizes the main steps of the protocol.

Illustration was created with BioRender.com. B. One negative sample (Neg S.) and one positive sample (Pos S.) before and after incubation. At t = 0 min (left panel), all samples were pink.

After incubation of 30min (right panel), positive samples turned yellow while negative samples retained their pink color. Pictures are representative RT-LAMP test results of clinical diagnostic

nasal and throat swabs of data published in Ben-Assa*, Naddaf* et al., 2020. Results were confirmed by conventional RT-qPCR clinical test for SARS-CoV-2 following RNA extraction and

purification step.

Notes

1. Alternative to a PCR machine, any heating source (e.g., water bath) can be used for Steps B5 and C2. We have successfully used a thermos cup and a thermometer to adjust water

temperature. 2. Longer incubation than 40 min may result in non-specific color change and interpreted as false

positive results. 3. It is very important to use proper personal protective equipment when handling the samples

starting from step B and throughout the rest of the protocol. 4. The color change in the protocol is an indication for a binary positive/negative result and does

not represent any gradient indication of the clinical status of the patient.

Please cite this article as: Naddaf et. al., (2020). A Protocol for Simple, Rapid, and Direct Detection of SARS-CoV-2 from clinical samples, using ReverseTranscribed Loop-Mediated Isothermal Amplification (RT-LAMP),Bio-protocol 10 (20): e3789. DOI: 10.21769/BioProtoc.3789.

Page 6: A Protocol for Simple, Rapid, and Direct Detection of SARS

Copyright © 2020 The Authors; exclusive licensee Bio-protocol LLC. 6

www.bio-protocol.org/e3789 Bio-protocol 10(20): e3789. DOI:10.21769/BioProtoc.3789

Recipes

1. Primer mix

a. Prepare each one of the primers at 100 µM b. Primer mix:

F3 2 µl (2 µM final concentration) B3 2 µl (2 µM final concentration)

LF 4 µl (4 µM final concentration) LB 4 µl (4 µM final concentration)

FIP 16 µl (16 µM final concentration) BIP 16 µl (16 µM final concentration)

c. DNase RNase free water 56 µl d. Aliquot and store at -20 °C

2. Proteinase K at stock concentration 28.67 (mg/ml) Soluble in DNase RNase free water

Store at -20 °C 3. Guanidine hydrochloride

Soluble in DNase RNase free water Stock concentration, 800 mM

Store at room temperature

Acknowledgments

We thank the Geva-Zatorsky lab for fruitful discussions and contributions. We would like to thank the Rambam hospital for their support and for hosting us, especially to the infectious disease and

virology teams. We would also like to thank Dr. Rich Roberts and Dr. Nathan Tanner for their valuable support, as well as Prof. Daniel King, Prof. Yehuda Chowers, Dr. Ronit Almog, Dr. Yuval Geffen, Dr.

Dani Zvi-Bar and Prof. Oded Lewinson for their crucial help. In addition, we would like to thank Dima Abdu for preparing the figure for this paper. The illustration in this in Figure 1B was created with

BioRender.com. This work was supported by the Technion Integrated Cancer Center, the Technion – Israel Institute

of Technology, “Keren Hanasi”, Alon Fellowship for Outstanding Young Researchers, Horev Fellow (Taub Foundation). NGZ is an Azrieli Global Scholar at the Canadian Institute for advanced research

(CIFAR).

Please cite this article as: Naddaf et. al., (2020). A Protocol for Simple, Rapid, and Direct Detection of SARS-CoV-2 from clinical samples, using ReverseTranscribed Loop-Mediated Isothermal Amplification (RT-LAMP),Bio-protocol 10 (20): e3789. DOI: 10.21769/BioProtoc.3789.

Page 7: A Protocol for Simple, Rapid, and Direct Detection of SARS

Copyright © 2020 The Authors; exclusive licensee Bio-protocol LLC. 7

www.bio-protocol.org/e3789 Bio-protocol 10(20): e3789. DOI:10.21769/BioProtoc.3789

Competing interests

The author(s) declared no potential conflicts of interest with respect to the research, authorship,

and/or publication of this article. While performing this research, no company had invested in the research, and no commercialization was intended.

Ethics

This study was granted exemption from IRB approval of the Rambam Health Care Campus (# 0244-

20-RMB) for use of de-identified COVID-19 tests performed for the purpose of the standard testing, and for 4 volunteers.

References

1. Ben-Assa, N., Naddaf, R., Gefen, T., Capucha, T., Hajjo, H., Mandelbaum, N., Elbaum, L.,

Rogov, P., King, D. A., Kaplan, S., Rotem, A., Chowers, M., Szwarcwort-Cohen, M., Paul, M. and Geva-Zatorsky, N. (2020). Direct on-the-spot detection of SARS-CoV-2 in patients. Exp Biol

Med (Maywood) 245(14): 1187-1193. 2. Bruce, E. A., Huang, M. L., Perchetti, G. A., Tighe, S., Laaguiby, P., Hoffman, J. J., Gerrard, D.

L., Nalla, A. K., Wei, Y., Greninger, A. L., Diehl, S. A., Shirley, D. J., Leonard, D. G. B., Huston, C. D., Kirkpatrick, B. D., Dragon, J. A., Crothers, J. W., Jerome, K. R. and Botten, J. W. (2020).

DIRECT RT-qPCR DETECTION OF SARS-CoV-2 RNA FROM PATIENT NASOPHARYNGEAL SWABS WITHOUT AN RNA EXTRACTION STEP. bioRxiv. doi: 10.1101/2020.03.20.001008.

3. Curtis, K. A., Morrison, D., Rudolph, D. L., Shankar, A., Bloomfield, L. S. P., Switzer, W. M. and Owen, S. M. (2018). A multiplexed RT-LAMP assay for detection of group M HIV-1 in plasma or

whole blood. J Virol Methods 255: 91-97. 4. Notomi, T., Okayama, H., Masubuchi, H., Yonekawa, T., Watanabe, K., Amino, N., and Hase, T.

(2000). Loop-mediated isothermal amplification of DNA. Nucleic Acids Res 28(12): e63-e63. 5. Wang, X., Yin, F., Bi, Y., Cheng, G., Li, J., Hou, L., Li, Y., Yang, B., Liu, W. and Yang, L. (2016).

Rapid and sensitive detection of Zika virus by reverse transcription loop-mediated isothermal amplification. J Virol Methods 238: 86-93.

6. Yu, L., Wu, S., Hao, X., Dong, X., Mao, L., Pelechano, V., Chen, W. H. and Yin, X. (2020). Rapid Detection of COVID-19 Coronavirus Using a Reverse Transcriptional Loop-Mediated Isothermal

Amplification (RT-LAMP) Diagnostic Platform. Clin Chem 66(7): 975-977. 7. Zhang, Y., Odiwuor, N., Xiong, J., Sun, L., Nyaruaba, R. O., Wei, H., and Tanner, N. A. (2020).

Rapid Molecular Detection of SARS-CoV-2 (COVID-19) Virus RNA Using Colorimetric LAMP. MedRxiv doi: https://doi.org/10.1101/2020.02.26.20028373.

Please cite this article as: Naddaf et. al., (2020). A Protocol for Simple, Rapid, and Direct Detection of SARS-CoV-2 from clinical samples, using ReverseTranscribed Loop-Mediated Isothermal Amplification (RT-LAMP),Bio-protocol 10 (20): e3789. DOI: 10.21769/BioProtoc.3789.