a well balanced temperature flow on the inside decreases the damaging effects … · 2013-12-03 ·...

6
A well balanced temperature flow on the inside decreases the damaging effects on the outside environment Four packages covering all demands for the balancing of heating- and cooling systems. Read more on the following pages.

Upload: others

Post on 03-Feb-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: A well balanced temperature flow on the inside decreases the damaging effects … · 2013-12-03 · A well balanced temperature flow on the inside decreases the damaging effects on

A well balanced temperature flow on the inside decreases the damaging effects on the outside environment

Four packages covering all demands for the balancing of heating- and cooling systems. Read more on the following pages.

Page 2: A well balanced temperature flow on the inside decreases the damaging effects … · 2013-12-03 · A well balanced temperature flow on the inside decreases the damaging effects on

A smarter flow

A new instrument in four packages covering all possible balancing needs for heating and cooling systems.We were the first to introduce wireless balancing in-

struments on the market. Now we take it a step further.

Our new PFM FLEX instrument is the most ergonomic

on the market with a weight of only a third of our previ-

ous instrument. Flexibility was the core value guiding

the development of the instrument and it is sold in four

different packages covering the different needs posed

by its users. The price of the first step package com-

petes directly with the cheapest instruments on the

market. It is easy to upgrade to the next level in order

to cover your extended balancing needs. The work

flows more easily due to PFM FLEX’s ability to com-

municate directly with your mobile hand piece as well

as with your laptop. No balancing assignments are too

great since the instrument is so easy to upgrade to fit

new demands. This increases the economical flow as

well as the profit. PFM FLEX Easy Flow.

Page 3: A well balanced temperature flow on the inside decreases the damaging effects … · 2013-12-03 · A well balanced temperature flow on the inside decreases the damaging effects on

Better communication

The new PFM FLEX measuring sensor communicates wire-lessly via bluetooth, with both your hand device as well as with your laptop. This enables gathered data to be directly transmit-ted to your laptop during the balancing of heating and cooling systems. PFM FLEX also communicates with several Smart Phones. This allows for greater flexibility and a better workflow.

Page 4: A well balanced temperature flow on the inside decreases the damaging effects … · 2013-12-03 · A well balanced temperature flow on the inside decreases the damaging effects on

Contents

Measurement Range

-Total Pressure: max 2500kPa

-Differential Pressure: 0-1000kPa. Optional: 0-2000kPa

-Static pressure: < 1000kPa. Optional: < 2000kPa

-Ambient temp T0: -10°C - +40°C

-System temp T1: -30°C - +120°C

-System temp T2: -30°C - +120°C

Measurement deviation

-Differential Pressure: < 0,1% of Full Scale

-Flow: as for differential pressure + valve deviation

-Temperature: < 0,2°

Battery capacity, operating and charge time

Hand Terminal:

-Battery Capacity: 1200mAh. Extended: 3900mAh

-Operating Time: 8 hours. Extended: 24 hours. Continous Duty

-Charging time: 1,4 hours. Extended: 4,5 hours

Sensor:

-Battery Capacity: 6600mAh

-Operating Time: 35 hours. Continous Duty

-Charging time: >90% 4 hours

Ambient temperature for the instrument

- During operation and charging: 0°C - +40°C

- During storage: -20°C - +60°C

Humidity

Ambient humidity: max 90%RH

Weight

-Sensor: 540gr

-Complete Case: 2,8kg

Open space range:

> 200m. >500m with antenna

IP-class

Sensor: IP65

Technical specification PFM FLEX

Package contents

• Hand terminal

• Sensor

• Hand terminal charger

• USB cable

• Sensor charger

• Tubing x 2

• Measurement needles x 2

• Allen keys

• Manual

• Program license

• Calibration report

• CD with Balance software

• Carrying case

Optional

• External BT Antenna

• Temp probes

• Cable communications

• Use of several Sensors

Grow with

your assignment

in four steps.

Page 5: A well balanced temperature flow on the inside decreases the damaging effects … · 2013-12-03 · A well balanced temperature flow on the inside decreases the damaging effects on

Measuring method 1 & 2Valve library

Measuring method 1 & 2Valve librarySaveSwitch mode

Measuring method 1 & 2Valve librarySaveSwitch modeGraphical presentationSet-Value

Measuring method 1 & 2Valve librarySaveSwitch modeGraphical presentationSet-ValueMediaEnergy & Power Log functionScope presentation

Choose a package PFM FLEX is delivered with one out of four software packages. Pick the one most suitable for your company’s balancing needs. It is easy to upgrade to the next package as your balancing demands increases.

Page 6: A well balanced temperature flow on the inside decreases the damaging effects … · 2013-12-03 · A well balanced temperature flow on the inside decreases the damaging effects on