Page 1: A1...Volume of sandy loam required to fill Strata Cell and Root Director spaces (including root ball volume) = approximately 16.2 Cu. m. Additional allowance needs to be made for settlement
Page 2: A1...Volume of sandy loam required to fill Strata Cell and Root Director spaces (including root ball volume) = approximately 16.2 Cu. m. Additional allowance needs to be made for settlement

PLAN VIEW WITH CANOPY HIDDEN1:33.33

SASLP Arborguy strapped anchorsystem c/w ground anchors

Footpath/road construction

SIDE VIEW1:33.33

ISOMETRIC VIEW WITH CUT-AWAY TO SHOW PRODUCTS1:33.33

A A

PARTIAL SECTION A-A

GLTWGNA twinwall geonetlaid over StrataCells

Drainage to engineers detail

Galvanised tree grille supportframe set on concrete haunch

RD1400A Root Director, large,modular root barrier system

GLSCMA StrataCell structure - 3 modulesdeep x 9 modules square (3 x 3 x 3

void below Root Director) loadedwith topsoil - sandy loam to BS3882

ULLS186A Ullswatervertical steel tree guard

1.8m high x 600mmdiameter secured to grille

Package includes:

RRPREC1C RootRain Precinct single inlet aeration/irrigationsystem with cast inlet

RRARBVDI3C Arborvent double inlet aeration/irrigation systemwith cast inlets

GLSCMA StrataCells, 216 No. 500mm x 500mm x 250mm

GLTWGNA twinwall geonet - 27 Sq. m

ADUR15A Adur 1500mm x 1500mm tree grille, finished in black, with galvanised steel support frame

ULLS186A Ullswater vertical steel tree guard, with rolledangle-section rings, 16mm round vertical bars topped with50mm diameter ball finials, finished in black

RD1400A Root Director

GLGTTA Tree guard tie

SASLP Arborguy strapped anchor system - Large Note: Special drive rod required for SASLP installation Volume of sandy loam required to fill Strata Cell and Root Director spaces (including root ball volume) = approximately 16.2 Cu. m. Additional allowance needs to be made for settlement

RRPREC1C RootRainPrecinct irrigation system

RRARBVDI3C Arborvent doubleinlet aeration/irrigation system

3000Aprx.

1330A

prx.

560

Aprx.

GLGTTA Tree guard tieattached to the top ring

of the tree guard

ADUR15A1500mm x 1500mm

tree grille c/wRootRain Precicnt

irrigation inlet

4500Aprx.

DRAWNCHECKEDENG APPRMGR APPR

UNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN MILLIMETERS

ANGLES ±X.X°2 PL ±X.XX 3 PL ±X.XXX

NAMEAdrian White

DATE21/02/2011

TITLE

GR1022 Tree pit system installationSIZE

A1DWG NO

GRE-101113-DFT-001REVC

GR1022.dftSCALE: WEIGHT: SHEET 1 OF 1

REVISION HISTORYREV DESCRIPTION DATE APPROVED

TREE PRODUCT PACKAGES

FILENAME:

Greenleaf Urban tree and landscape products3 Hayward Way, Ivyhouse Industrial Estate, Hastings, East Sussex TN35 4PL

Tel: +44 (0)1424 717 797 Fax: +44 (0)1424 205 240E-mail: [email protected] Website: www.treesintowns.com