a301 deck sections & details€¦ · deck sections & details e ve se h d s n , s . r...

1
Dynamic Network Services, Inc. 150 Dow Street Manchester New Hampshire teamwork://g5server/Dyn-Inc-2010058_v3 Tuesday, March 22, 2011 2010-058 revisions: A301 date: proj. no.: Deck Sections & Details The material contained in these drawings and the design they are intended to convey are the exclusive property of Dennis B. Mires. Possession and use hereof is granted only confidentially in connection with construction and / or sale of the structure depicted herein as authorized by him, and the recipient agrees to abide by these restrictions. Any use, reproduction or desclosure of any information, in whole or in part, contained herein, without written permission of Dennis B. Mires, is expressly prohibited. ETR 2'-0" 9'-6" 2'-0" 13'-6" 5'-0" 2'-0" 6'-4" V.I.F 9'-3" V.I.F 1'-0" 1'-0" 14'-0" 2'-0" 16'-0" 40kw GENERATOR 7" HIGH RAISED ABOVE GROUND LEVEL, 5" MIN CONCRETE SLAB WITH 12" MIN BELOW GRADE TURNED DOWN EDGES ON 12" CRUSHED GRAVEL & REINFORCING AS REQUIRED TO SUPPORT GENERATOR. CO- ORDINATE EDGE/SLAB DEPTHS WITH ARCHITECT & ENGINEER STRUCTURAL NOTE: "The two post footings should be Bigfoot Systems BF 36. These can accept 18" diameter sonotubes. The sonotubes should have four #4 vertical bars for reinforcement. Column baseplates should be 5/8" x 11" square with holes for four 5/8"ø anchor rods embedded 10" into concrete." VERIFY SLAB DIMENSIONS ONCE GENERATOR IS SELECTED C A301 C A301 A A301 B A301 13'-6" 16'-0" A A301 B A301 DECK EXISTING OPENING TO BE MODIFIED FOR NEW DOOR. PROVIDE & INSTALL ADA COMPLIANT SILL, THRESHOLD & GASKETS FOR NEW DOOR TO ENSURE DOOR IS WATERPROOF. PRESSURE TREATED SOUTHERN YELLOW PINE DENSE SELECT GRADE, 3 1/2" x 6" RECTANGULAR STRUCTURAL DECKING SUPPORTED ON SLEEPERS. DECKING TO BE NAIL SPACED GAPS BETWEEN BOARDS. D127A EXISTING WINDOW TO BE REMOVED & OPENING MODIFIED FOR NEW ALUMINUM EXTERIOR DOOR WITH SIDELITE & TRANSOM AS SHOWN. PROVIDE ADA COMPLIANT EXTERIOR THRESHOLD & WEATHERSTRIPPING NEW 40KW GENERATOR ON RAISED SLAB EXISTING TRANSFORMER TO REMAIN 14'-0" 2'-0" 2'-0" 1'-6" STRUCTURAL NOTE: "The two beams perpendicular to the building wall should be cantilevered over the columns. Beam to column connections should be made with 1/2" cap plates, four 3/4"ø bolts and 3/8" web stiffeners centered on the column. Connections to the wall should be made with 1/2" anchor plates and 3/8" x 4" x 6" shear plates. Anchor plates should be attached to the wall with six 5/8"ø rods embedded 10" with the Hilti HIT HY 20 adhesive system. Shear plates should be welded to the anchor plates with two vertical 3/16" x 6" welds. Beams should be attached to shear plates with two 3/4"ø bolts." STRUCTURAL NOTE: "The two post footings should be Bigfoot Systems BF 36. These can accept 18" diameter sonotubes. The sonotubes should have four #4 vertical bars for reinforcement. Column baseplates should be 5/8" x 11" square with holes for four 5/8"ø anchor rods embedded 10" into concrete." D A301 9'-6" 2'-0" 2'-0" 2'-0" STRUCTURAL NOTES: "Deck beams should be W8x18's. Columns should be HSS5x5x1/4's." "The short, non-structural W8x18 outriggers should be shop connected to W8x18 beams that bear on top of columns with 1/4" partial penetration welds for the full width of top and bottom flanges." "The beam spanning between columns should have braces at each end approximately 2'–0" down and away from beam and column centerlines. Braces should be capable of supporting a 6.0 kips axial force." 2'-0" HIGH CONCRETE PLYNTH, 18" DIA APPROX 13'-6" (V.I.F) 3" 3 1/2" 3'-6" 4" 3/4" 3 1/2" 1/2" 2" 1" PRESSURE TREATED SOUTHERN YELLOW PINE WOOD TOP RAIL. REBATE 1/2" FOR PLACEMENT OVER METAIL TOP RAIL. TOP TO BE SLOPED, ALL EDGES EASED, FINISH BY ARCHITECT METAL GUARDRAIL TO BE HOT DIPPED GALVANIZED AND PAINTED BLACK. TOP & BOTTOM RAILS TO BE 2"W x 3/4"H. POSTS TO BE 2" SQUARE & BALLISTERS TO BE 1" SQUARE. PRESSURE TREATED SOUTHERN YELLOW PINE DENSE SELECT GRADE, 3 1/2" x 6" RECTANGULAR STRUCTURAL DECKING SUPPORTED ON SLEEPERS. DECKING TO BE NAIL SPACED GAPS BETWEEN BOARDS. CO-ORDINATE ATTACHEMENT OF DECKING TO SLEEPER WITH ENGINEER 3/8" GALVINIZED, PTD STEEL PLATES MIN 2 MEMBER WIDTHS IN LENGTH (12" MIN), EITHER SIDE OF WOOD DECKING FOR STEEL POST SUPPORT. THREAD TO BE WELDED TO UNDERSIDE OF TOP PLATE, AND BOLTED FROM UNDERNEATH. PRESSURE TREATED SOUTHERN YELLOW PINE 3"x6" (FINISHED DIMENSIONS) SLEEPERS, FASTENED TO TOP OF STEEL BEAM. SLEEPER TO BE BOLTED FROM UNDERSIDE. NUT TO BE COUNTERSUNK INTO TOP OF WOOD SLEEPER & EXPOSED HEAD TO BE BUTTON HEAD ON BEAM SIDE. ALL FASTENERS TO BE STAINLESS STEEL W BEAM PER STRUCTURAL NOTES, GALVANIZED & PAINTED, COLOR BY ARCHITECT BEAM BEYOND TO SUPPORT PERIMETER HSS BEAM. ALL CANTILEVERED BEAM ENDS TO BE TRIMMED & END PLATE ADDED PER DRAWINGS SCALE: 1/4" = 1'-0" Basement/Foundation SCALE: 1/4" = 1'-0" Partial Enlarged Floor Plan SCALE: 1/4" = 1'-0" A West Deck Elevation SCALE: 1/4" = 1'-0" B Deck Elevation SCALE: 3/16" = 1'-0" Deck 3D View 1 SCALE: 3/16" = 1'-0" Deck 3D View 2 SCALE: 1/4" = 1'-0" C Typical Deck Section SCALE: 1" = 1'-0" D Typical Deck Edge Detail 03/21/11 ALL STRUCTURAL STEEL & STEEL GUARDRAILS/PLATES ARE TO BE HOT DIP GALVINIZED. ALL AREAS OF EXPOSED METAL ARE TO BE TOUCHED-UP IN FIELD WITH ZINC -RICH PRIMER . ALL STEEL IS TO BE PAINTED, COLOR TO BE BLACK

Upload: others

Post on 19-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: A301 Deck Sections & Details€¦ · Deck Sections & Details e ve se h d s n , s . R 2'-0" 9'-6" 2'-0" 13'-6" " " F 9 ... EXTERIOR THRESHOLD & WEATHERSTRIPPING NEW 40KW GENERATOR

Dyn

am

ic N

etw

ork

Se

rvic

es, I

nc.

15

0 D

ow

Str

ee

tM

anc

heste

r N

ew

Ha

mp

shi

re

team

wor

k://g

5ser

ver/D

yn-In

c-20

1005

8_v3

Tue

sday

, Mar

ch 2

2, 2

011

2010-058

revisions:

A301

03/10/11date:proj. no.:

Deck Sections& Details

The

mat

eria

l con

tain

ed in

thes

e dr

awin

gs a

nd th

ede

sign

they

are

inte

nded

to c

onve

y ar

e th

e ex

clus

ive

prop

erty

of D

enni

s B

. Mire

s. P

osse

ssio

n an

d us

ehe

reof

is g

rant

ed o

nly

conf

iden

tially

in c

onne

ctio

n w

ithco

nstru

ctio

n an

d / o

r sal

e of

the

stru

ctur

e de

pict

edhe

rein

as

auth

oriz

ed b

y hi

m, a

nd th

e re

cipi

ent a

gree

sto

abi

de b

y th

ese

rest

rictio

ns.

Any

use

, rep

rodu

ctio

nor

des

clos

ure

of a

ny in

form

atio

n, in

who

le o

r in

part,

cont

aine

d he

rein

, with

out w

ritte

n pe

rmis

sion

of D

enni

sB

. Mire

s, is

exp

ress

ly p

rohi

bite

d.

ETR

2'-0" 9'-6" 2'-0"13'-6"

5'-0

"2'

-0"

6'-4

" V.I.

F

9'-3" V.I.F

1'-0"1'-0"

14'-0

"2'

-0"

16'-0

"

40kwGENERATOR

7" HIGH RAISED ABOVEGROUND LEVEL, 5" MINCONCRETE SLAB WITH12" MIN BELOW GRADETURNED DOWN EDGES

ON 12" CRUSHED GRAVEL& REINFORCING AS

REQUIRED TO SUPPORTGENERATOR. CO-

ORDINATE EDGE/SLABDEPTHS WITH ARCHITECT

& ENGINEERSTRUCTURAL NOTE:"The two post footings

should be Bigfoot SystemsBF 36. These can accept18" diameter sonotubes.The sonotubes should

have four #4 vertical barsfor reinforcement. Columnbaseplates should be 5/8"x 11" square with holes for

four 5/8"ø anchor rodsembedded 10" into

concrete."

VERIFY SLABDIMENSIONS ONCE

GENERATOR ISSELECTED

CA301

CA301

AA301

BA301

13'-6"

16'-0

"

AA301

BA301

DECK

EXISTING OPENING TO BE MODIFIED FORNEW DOOR. PROVIDE & INSTALL ADACOMPLIANT SILL, THRESHOLD & GASKETSFOR NEW DOOR TO ENSURE DOOR ISWATERPROOF.

PRESSURE TREATED SOUTHERN YELLOWPINE DENSE SELECT GRADE, 3 1/2" x 6"RECTANGULAR STRUCTURAL DECKINGSUPPORTED ON SLEEPERS. DECKING TOBE NAIL SPACED GAPS BETWEEN BOARDS.

D127A

EXISTING WINDOW TO BE REMOVED& OPENING MODIFIED FOR NEW

ALUMINUM EXTERIOR DOOR WITHSIDELITE & TRANSOM AS SHOWN.

PROVIDE ADA COMPLIANTEXTERIOR THRESHOLD &

WEATHERSTRIPPING

NEW 40KWGENERATOR ON

RAISED SLAB

EXISTINGTRANSFORMER

TO REMAIN

14'-0" 2'-0"

2'-0

"

1'-6"

STRUCTURAL NOTE:"The two beams perpendicular to thebuilding wall should be cantilevered overthe columns. Beam to columnconnections should be made with 1/2"cap plates, four 3/4"ø bolts and 3/8" webstiffeners centered on the column. Connections to the wall should be madewith 1/2" anchor plates and 3/8" x 4" x 6"shear plates. Anchor plates should beattached to the wall with six 5/8"ø rodsembedded 10" with the Hilti HIT HY 20adhesive system. Shear plates should bewelded to the anchor plates with twovertical 3/16" x 6" welds. Beams shouldbe attached to shear plates with two3/4"ø bolts."

STRUCTURAL NOTE:"The two post footings should be BigfootSystems BF 36. These can accept 18"diameter sonotubes. The sonotubesshould have four #4 vertical bars forreinforcement. Column baseplatesshould be 5/8" x 11" square with holes forfour 5/8"ø anchor rods embedded 10"into concrete."

DA301

9'-6"

2'-0" 2'-0"

2'-0

"

STRUCTURAL NOTES:"Deck beams should be W8x18's. Columns should be HSS5x5x1/4's."

"The short, non-structural W8x18outriggers should be shop connectedto W8x18 beams that bear on top ofcolumns with 1/4" partial penetrationwelds for the full width of top andbottom flanges."

"The beam spanning betweencolumns should have braces at eachend approximately 2'–0" down andaway from beam and columncenterlines. Braces should be capableof supporting a 6.0 kips axial force."

2'-0" HIGH CONCRETEPLYNTH, 18" DIA

AP

PR

OX

13'

-6" (

V.I.F

)

3"3

1/2"

3'-6

"

4"3/

4"

3 1/2"

1/2"

2"

1"

PRESSURE TREATED SOUTHERN YELLOW PINE WOODTOP RAIL. REBATE 1/2" FOR PLACEMENT OVER METAILTOP RAIL. TOP TO BE SLOPED, ALL EDGES EASED,FINISH BY ARCHITECT

METAL GUARDRAIL TO BE HOT DIPPED GALVANIZED ANDPAINTED BLACK. TOP & BOTTOM RAILS TO BE 2"W x3/4"H. POSTS TO BE 2" SQUARE & BALLISTERS TO BE 1"SQUARE.

PRESSURE TREATED SOUTHERN YELLOW PINE DENSESELECT GRADE, 3 1/2" x 6" RECTANGULAR STRUCTURALDECKING SUPPORTED ON SLEEPERS. DECKING TO BENAIL SPACED GAPS BETWEEN BOARDS. CO-ORDINATEATTACHEMENT OF DECKING TO SLEEPER WITHENGINEER

3/8" GALVINIZED, PTD STEEL PLATES MIN 2 MEMBERWIDTHS IN LENGTH (12" MIN), EITHER SIDE OF WOODDECKING FOR STEEL POST SUPPORT. THREAD TO BEWELDED TO UNDERSIDE OF TOP PLATE, AND BOLTEDFROM UNDERNEATH.

PRESSURE TREATED SOUTHERN YELLOW PINE3"x6" (FINISHED DIMENSIONS) SLEEPERS, FASTENED TOTOP OF STEEL BEAM. SLEEPER TO BE BOLTED FROMUNDERSIDE. NUT TO BE COUNTERSUNK INTO TOP OFWOOD SLEEPER & EXPOSED HEAD TO BE BUTTON HEADON BEAM SIDE. ALL FASTENERS TO BE STAINLESSSTEEL

W BEAM PER STRUCTURAL NOTES, GALVANIZED &PAINTED, COLOR BY ARCHITECT

BEAM BEYOND TO SUPPORT PERIMETER HSS BEAM. ALLCANTILEVERED BEAM ENDS TO BE TRIMMED & ENDPLATE ADDED PER DRAWINGS

SCALE: 1/4" = 1'-0"Basement/Foundation

SCALE: 1/4" = 1'-0"Partial Enlarged Floor Plan

SCALE: 1/4" = 1'-0"A West Deck Elevation

SCALE: 1/4" = 1'-0"B Deck Elevation

SCALE: 3/16" = 1'-0"Deck 3D View 1

SCALE: 3/16" = 1'-0"Deck 3D View 2

SCALE: 1/4" = 1'-0"C Typical Deck Section

SCALE: 1" = 1'-0"D Typical Deck Edge Detail

03/21/11

ALL STRUCTURAL STEEL & STEEL GUARDRAILS/PLATESARE TO BE HOT DIP GALVINIZED. ALL AREAS OF

EXPOSED METAL ARE TO BE TOUCHED-UP IN FIELD WITHZINC -RICH PRIMER . ALL STEEL IS TO BE PAINTED, COLOR

TO BE BLACK