aaview a view b detail c (shown w/out shower) detail c 6 cp-2 gasket 167219-02-cht under wood floor...
TRANSCRIPT
6
A
1
CHKR
DO NOT SCALE DRAWING
4
ONE-PLACE (X.X)
SHEET
7
REV
DWGNO
DFTR
1
MATERIAL:
DSNR
REV
TWO-PLACE (X.XX)
5
ZONE
A
ANGLE
6 5
8
REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES
WHOLE DIM (X)
4
REVISION RECORD
FIRST USEDM.E.
C
B
TITLE:
OF
C
DATE
3
DFTR-ORIG
2
THIRD ANGLE
D
REV
D
P.E.
ORIG. DATE
B
DATE
UNSPECIFIED TOLERANCES ARE:
COPYRIGHT 2014WINNEBAGO
INDUSTRIES, INC.
2 REF:
ALL DIMENSIONS ARE IN MILLIMETERS
8
PROJECTION
7
3
PART NO
A
14 170A
1.50.501
1 4
3
186563
DRAINAGE SYSTEM INSTL
RELEASE
186563
X-X
9 USE SMOOTH PLUMBERS PUTTY 167459-01-000 TO SEAL STRAINER (0.2 PER STRAINERS)
8 NIPPLE TO BE TRIMMED TO LENGTH ON INSTALL.
7 TRIM TO FIT.
6 VENT PIPE MUST PROJECT 51 MIN AND 64 MAX ABOVE ROOF FOR PROPER FIT AND FUNCTION.
5. SEAL AROUND SHOWER WITH SILICONE.
4. SECURE DRAINAGE PIPES TO CABINET USING WIRE TIE 108046-02-000, AND SCREW 000G67-10-12B AT INTERVALS OF NOT MORE THAN 4 FEET APART.
3. ALL PIPE AND FITTINGS TO BE ASSEMBLED WITH SOLVENT 004020-01-000 (USA), 004020-02-000 (CAN)
2. SLOPE OF TRAP ARM MUST BE 6 PER 305 mm.
1. SLOPE OF HORIZONTAL PIPING TO BE MINIMUM OF 3 PER 305 mm.NOTES:
DRAINAGEFOR
CALLOUTSSEE DWG NO
116229-01-000
A
B
*186563 *
AAAA
SECTION AA-AA
300
41
SHOWER PAN
SPRAYER BRKT
CABINET FRAME
*186563 *
24-Nov-2014
A
2
C
DO NOT SCALE DRAWING
D
PART NO
C
DWGNO
1
REV
5
5
A
4
D
16
8
B
3
7
TITLE:
SHEET
8
3 2
7
6
4
B
FIRST USED
14 170A
2
186563
DRAINAGE SYSTEM INSTL
186563
CP-2
G-1
G-1
E-6
E-1
E-1
1650
1935
SINK-LAV151679-01-CHTSEAL091255-03-000 (915)STRAINER163569-01-000
SINK-GALLEY165378-01-CHTSTRAINER163569-01-000
A-9
ARM-WASTE126588-02-000
ARM-WASTE126588-02-000
TRAP-WATERLESS165406-01-000
TRAP-WATERLESS165406-01-000
Y-1
ADAPTER-ANGLE165406-02-000
1130
7
6
1400
SPACER166672-06-CHTSCREW000G39-10-16U (6)
GASKET167219-03-CHT(UNDER WOOD FLOOR)
1185
E-5
155
1100
E-1
VIEW A
VIEW B
DETAIL C(SHOWN W/OUT SHOWER)
DETAIL C
CP-26
GASKET167219-02-CHTUNDER WOOD FLOOR
280
STRAINER066440-01-000SEALANT084456-01-000
SHOWER INSTL180599-01-XXX
G-2
A-15
FLANGE167352-01-000SCREW087721-01-000(6)
GASKET167219-03-CHT(UNDER WOOD FLOOR)
SPACER166672-06-CHTSCREW000G39-10-16U (6)
ADAPTER-ANGLE165406-02-000
DETAIL E
DETAIL E
TRAP-WATERLESS165406-01-000
A-15
A-15
A-9 C-4
C-4
1625
1380
1525
11010
1160
1325
1320
1260
1175
1115
1140
1110
E-6
E-6
E-6
E-1
E-1
E-1
E-1
T-1
B-2 PL-1 155
E-53
S-2
S-2
C-3 A-10
N-1
C-3
155
W-7
7
7
CLAMP062401-02-000
CLAMP062401-02-000
*186563 *
9
9
W-7
TOILET160815-04-CHT
4100
ADAPTER-ANGLE165406-02-000
W-7
W-7
*186563 *
1100
24-Nov-2014
A
2
C
DO NOT SCALE DRAWING
D
PART NO
C
DWGNO
1
REV
5
5
A
4
D
16
8
B
3
7
TITLE:
SHEET
8
3 2
7
6
4
B
FIRST USED
14 170A
3
186563
DRAINAGE SYSTEM INSTL
186563
TANK ASM-HOLDING180500-02-000
TANK ASM-HOLDING180552-02-000
C-2
E-13
2210
2175
N-3
E-3
HANDLE-EXTENTION062419-13-000 (2)HANDLE(USE HANDLE SUPPLIED WITH VALVE)
U-CHANNEL165872-01-CHT
BOLT-J091274-08-000 (6)NUT000D29-06-00U (6)WASHER000E13-18-00U (6)
GASKET167219-01-CHTUNDER WOOD FLOOR
1350
1170
SHIELD-HEAT,EXHAUST166164-07-CHT
VIEW D
SHIELD-HEAT,EXHAUST166164-08-CHTSCREW-SF/DR 10-16X.625 PPH000G39-10-10U (4)
H-1V-12
A-9
A-1
A-4
FOAM100619-B3-003
FOAM100619-B3-002
FOAM100619-B3-001FOAM
100619-B3-001
C-4
CHANNEL ASM-TANK179475-02-CHT
C-2
CP-1
E-11
FITTING-SPINWELD010232-01-000
1244
1009
1209
6
890
1389
DATUM
FRONTAXLE
VEHICLE
CHANNEL ASM-TANK179475-01-CHT
D
HANGLE-W/HOLE156309-05-CHT(2)SCREW000G39-10-10U(8)
CLAMP083610-02-000
275
FOAM100619-C1-001
ANGLE-SUPPORT168448-02-CHT
2220
*186563 *
ANGLE-SUPPORT187647-02-CHTCLAMP083610-02-000
*186563 *
24-Nov-2014
A
2
C
DO NOT SCALE DRAWING
D
PART NO
C
DWGNO
1
REV
5
5
A
4
D
16
8
B
3
7
TITLE:
SHEET
8
3 2
7
6
4
B
FIRST USED
14 170A
4
186563
DRAINAGE SYSTEM INSTL
186563
KK
SECTION K-K
FF
SECTION F-F
JJ
SECTION J-J
123
32
DRILL 19 HOLETHROUGH FRAME MEMBER
DRILL 19 HOLETHROUGH FRAME MEMBER
DRILL 19 HOLETHROUGH FRAME MEMBER
119
25
24
119VIEW H
*186563 *
*186563 *
24-Nov-2014
6
A
1
CHKR
DO NOT SCALE DRAWING
4
ONE-PLACE (X.X)
SHEET
7
REV
DWGNO
DFTR
1
MATERIAL:
DSNR
REV
TWO-PLACE (X.XX)
5
ZONE
A
ANGLE
6 5
8
REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES
WHOLE DIM (X)
4
REVISION RECORD
FIRST USEDM.E.
C
B
TITLE:
OF
C
DATE
3
DFTR-ORIG
2
THIRD ANGLE
D
REV
D
P.E.
ORIG. DATE
B
DATE
UNSPECIFIED TOLERANCES ARE:
COPYRIGHT 2014WINNEBAGO
INDUSTRIES, INC.
2 REF:
ALL DIMENSIONS ARE IN MILLIMETERS
8
PROJECTION
7
3
PART NO
A
14 170A
1.50.501
1 3
3
186564
WATER SYSTEM INSTL
RELEASE
186564
A
FRONTOF
COACH
29B WATER PURIFIER
501 WATER PURIFIER WITHOUT
53F WATER HEATER-ELEC IGNITION
53B WTR HTR-6 GAL ELEC/LP/GAS
CALLOUTSSEE DWG NO
116230-01-000
FORWATER
NOTES:
10 SECURE VALVE HANDLE W/SILICOLN
9 PARTS TO BE ASSEMBLED AND ABLE TO BE REMOVED AND STORED AS A SINGLE ASM.
8. ALL CRIMP FITTINGS TO 1/2" PEX TUBING REQUIRE 1/2" CLAMP 140171-03-000.
7. ALL CRIMP FITTINGS TO 5/8" PEX TUBING REQUIRE 5/8" CLAMP 140171-04-000.
6 LABEL HOT AND COLD SUPPLY TUBES AND TAPE FITTING TO TUBE BEFORE CABINET SET TO PREVENT MOVEMENT.
5 ADD PIPE WRAP (LADDER SCRAP 110157-02-000) INSULATION.
4 ADD TEFLON TAPE 010405-02-000.
3. ALL TUBING TO BE SECURED AT 1200 INTERVALS MAXIMUM WITH CLAMP 010495-01-000 AND SCREW 000G67-10-12B OR EQUIVALENT.
2. TUBING TO BE INSTALLED WITH SUFFICIENT SLOPE TO PROVIDE DRAINAGE TO NEAREST VALVE.
1. PLASTIC FITTINGS TO BE SEALED WITH SEALANT 084456-01-000.X-X
*186564 *
*186564 *
*186564 *
13-Nov-2014
A
2
C
DO NOT SCALE DRAWING
D
PART NO
C
DWGNO
1
REV
5
5
A
4
D
16
8
B
3
7
TITLE:
SHEET
8
3 2
7
6
4
B
FIRST USED
14 170A
2
186564
WATER SYSTEM INSTL
186564
WATER HEATER051391-03-000145541-02-000DOOR125420-06-CHTCABLE076767-03-000SCREW000G39-10-169 (16)FLANGE-WATER HEATER180797-01-CHTADAPTER-BRASS136333-01-000CLOSEOUT ASM180780-01-CHT
FAUCET-LAV148886-02-CHT
S-1
PANEL-WATER PUMP149477-02-CHTSCREWG39-08-16U (4)FOAM140364-01-CHTSCREWG39-08-24U (4)
PW-5F-9
FILTER KIT KIT160946-03-000SCREW000G67-10-12U (2)
R-3
R-5600600
TO TOILET
V-6
501
44
SHOWER-EXTERIOR166291-01-CHTHOSE ASM-W/SPRAYER166291-02-000
TU10260
GROMMET071015-13-000
T-28
53B
TU-8380
53F
A-19
VIEW A
29B
29B
DETAIL B(SHOWN W/OUT SHOWER)
DETAIL B
T-29
E-44E-44
V-22
DETAIL G
DETAIL G
T-28
DETAIL H(SHOWN W/OUT SHOWER)
DETAIL H
T-28
T-29
T-28
T-28
T-28
E-46
E-44
E-44
E-43
E-43
E-43
R-2
A-27
FAUCET-GALLEY165378-02-CHT
R-2
V-11
WASHER-PLASTIC180671-02-CHT
GROMMET071015-13-000 (2)
TU10100
TU1040
TU10135TU10
95
TU10195
TU-980
TU-9245
TU-980
TU-965
TU-91375
TU101250
TU10110
TU-995
TU-9850
TU-8615
TU-91345
TU-9 40
TU-92980
TU103020
TU-8650
TU10330
TU-965
TU1065
TU1085
TU-985
VIEW J
T-28
E-46
T-28
E-43
TU10220
TU-9245
V-22
TU-955
TU10480
TU-9450
*186564 *
E-38
SHOWER-HAND HELD, WALL MOUNT187372-01-CHT
E-43
TU-955
*186564 *
*186564 *
V-72
A-282
13-Nov-2014
A
2
C
DO NOT SCALE DRAWING
D
PART NO
C
DWGNO
1
REV
5
5
A
4
D
16
8
B
3
7
TITLE:
SHEET
8
3 2
7
6
4
B
FIRST USED
14 170A
3
186564
WATER SYSTEM INSTL
186564
TANK ASM-WATER,28 GAL165457-02-000
U-CHANNEL165872-03-CHT (3)BOLT-HOOK091274-08-000 (3)BOLT-HOOK091274-06-000 (3)WASHER000E13-18-00U (6)NUT000D29-06-00U (6)
U-CHANNEL165872-03-CHTBOLT-HOOK091274-08-000BOLT HOOK091274-06-000WASHER000E13-18-00U (2)NUT000D29-06-00U (2)
SHIELD ASM-EXHAUST166164-01-CHT S-1
S-1
E-21
T-29
TU-3230
TU-9855
TU-92100
9
TU-9905
NUT000D39-06-00U (3)TOP SIDE OFCHANNEL
F-13
TU-4800
A-4
NUT000D39-06-00UTOP SIDE OFCHANNEL
TUBE122737-51-088TAPE76322-02-000 (400)(TAPE TUBE TO TOP OF CHANNEL)
CLAMP-HOSE062401-01-000
PANEL-WATER CENTER167283-07-CHT
TU-9 65
TU-9130
GROMMET016188-10-000
GROMMET023942-01-000
DETAIL F
DETAIL F
VIEW C
WATER LINES AND TANKS UNDER FLOOR
F-5
TU-950
FILL-GRAVITY166288-01-CHT
C
VIEW E
T-28T-28
E-21
E-44
E-43E-43
E-43
E-43
E-43
E-43E-43
E-43
A-30
PANEL-GRAVITY FILL166584-03-CHTCLAMP062401-01-000 (2)
V-11
CLAMP010495-04-000 (2)RIVET113133-03-CHT (2)
E-43
TU-995
TU-960
TU-985
TU-995
TU-960
TU-9255
TU-9135
TU-9215
TU-9135
TU-940
TU-940
TU-950
TU-940
TU-945
TU-940
TU-940
E-43
TU-955
TU-945
E
TU-940
10
A-13
CH-5 9
E-35
*186564 *
9
CLAMP010495-04-000RIVET113133-03-CHT
V-233
*186564 *
E-46
TU-940
V-22
TU-940
E-46
*186564 *
13-Nov-2014