aaview a view b detail c (shown w/out shower) detail c 6 cp-2 gasket 167219-02-cht under wood floor...

7
6 A 1 CHKR DO NOT SCALE DRAWING 4 ONE-PLACE (X.X) SHEET 7 REV DWG NO DFTR 1 MATERIAL: DSNR REV TWO-PLACE (X.XX) 5 ZONE A ANGLE 6 5 8 REFER TO ES0018 FOR FASTENER TIGHTENING GUIDELINES WHOLE DIM (X) 4 REVISION RECORD FIRST USED M.E. C B TITLE: OF C DATE 3 DFTR-ORIG 2 THIRD ANGLE D REV D P.E. ORIG. DATE B DATE UNSPECIFIED TOLERANCES ARE: COPYRIGHT 2014 WINNEBAGO INDUSTRIES, INC. 2 REF: ALL DIMENSIONS ARE IN MILLIMETERS 8 PROJECTION 7 3 PART NO A 14 170A 1.5 0.50 1 1 4 3 186563 DRAINAGE SYSTEM INSTL RELEASE 186563 X-X 9 USE SMOOTH PLUMBERS PUTTY 167459-01-000 TO SEAL STRAINER (0.2 PER STRAINERS) 8 NIPPLE TO BE TRIMMED TO LENGTH ON INSTALL. 7 TRIM TO FIT. 6 VENT PIPE MUST PROJECT 51 MIN AND 64 MAX ABOVE ROOF FOR PROPER FIT AND FUNCTION. 5. SEAL AROUND SHOWER WITH SILICONE. 4. SECURE DRAINAGE PIPES TO CABINET USING WIRE TIE 108046-02-000, AND SCREW 000G67-10-12B AT INTERVALS OF NOT MORE THAN 4 FEET APART. 3. ALL PIPE AND FITTINGS TO BE ASSEMBLED WITH SOLVENT 004020-01-000 (USA), 004020-02-000 (CAN) 2. SLOPE OF TRAP ARM MUST BE 6 PER 305 mm. 1. SLOPE OF HORIZONTAL PIPING TO BE MINIMUM OF 3 PER 305 mm. NOTES: DRAINAGE FOR CALLOUTS SEE DWG NO 116229-01-000 A B *186563 * AA AA SECTION AA-AA 300 41 SHOWER PAN SPRAYER BRKT CABINET FRAME *186563 * 24-Nov-2014

Upload: others

Post on 08-Jun-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AAVIEW A VIEW B DETAIL C (SHOWN W/OUT SHOWER) DETAIL C 6 CP-2 GASKET 167219-02-CHT UNDER WOOD FLOOR 2 80 STRAINER 066440-01-000 SEALANT 084456-01-000 SHOWER INSTL 180599-01-XXX G-2

6

A

1

CHKR

DO NOT SCALE DRAWING

4

ONE-PLACE (X.X)

SHEET

7

REV

DWGNO

DFTR

1

MATERIAL:

DSNR

REV

TWO-PLACE (X.XX)

5

ZONE

A

ANGLE

6 5

8

REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES

WHOLE DIM (X)

4

REVISION RECORD

FIRST USEDM.E.

C

B

TITLE:

OF

C

DATE

3

DFTR-ORIG

2

THIRD ANGLE

D

REV

D

P.E.

ORIG. DATE

B

DATE

UNSPECIFIED TOLERANCES ARE:

COPYRIGHT 2014WINNEBAGO

INDUSTRIES, INC.

2 REF:

ALL DIMENSIONS ARE IN MILLIMETERS

8

PROJECTION

7

3

PART NO

A

14 170A

1.50.501

1 4

3

186563

DRAINAGE SYSTEM INSTL

RELEASE

186563

X-X

9 USE SMOOTH PLUMBERS PUTTY 167459-01-000 TO SEAL STRAINER (0.2 PER STRAINERS)

8 NIPPLE TO BE TRIMMED TO LENGTH ON INSTALL.

7 TRIM TO FIT.

6 VENT PIPE MUST PROJECT 51 MIN AND 64 MAX ABOVE ROOF FOR PROPER FIT AND FUNCTION.

5. SEAL AROUND SHOWER WITH SILICONE.

4. SECURE DRAINAGE PIPES TO CABINET USING WIRE TIE 108046-02-000, AND SCREW 000G67-10-12B AT INTERVALS OF NOT MORE THAN 4 FEET APART.

3. ALL PIPE AND FITTINGS TO BE ASSEMBLED WITH SOLVENT 004020-01-000 (USA), 004020-02-000 (CAN)

2. SLOPE OF TRAP ARM MUST BE 6 PER 305 mm.

1. SLOPE OF HORIZONTAL PIPING TO BE MINIMUM OF 3 PER 305 mm.NOTES:

DRAINAGEFOR

CALLOUTSSEE DWG NO

116229-01-000

A

B

*186563 *

AAAA

SECTION AA-AA

300

41

SHOWER PAN

SPRAYER BRKT

CABINET FRAME

*186563 *

24-Nov-2014

Page 2: AAVIEW A VIEW B DETAIL C (SHOWN W/OUT SHOWER) DETAIL C 6 CP-2 GASKET 167219-02-CHT UNDER WOOD FLOOR 2 80 STRAINER 066440-01-000 SEALANT 084456-01-000 SHOWER INSTL 180599-01-XXX G-2

A

2

C

DO NOT SCALE DRAWING

D

PART NO

C

DWGNO

1

REV

5

5

A

4

D

16

8

B

3

7

TITLE:

SHEET

8

3 2

7

6

4

B

FIRST USED

14 170A

2

186563

DRAINAGE SYSTEM INSTL

186563

CP-2

G-1

G-1

E-6

E-1

E-1

1650

1935

SINK-LAV151679-01-CHTSEAL091255-03-000 (915)STRAINER163569-01-000

SINK-GALLEY165378-01-CHTSTRAINER163569-01-000

A-9

ARM-WASTE126588-02-000

ARM-WASTE126588-02-000

TRAP-WATERLESS165406-01-000

TRAP-WATERLESS165406-01-000

Y-1

ADAPTER-ANGLE165406-02-000

1130

7

6

1400

SPACER166672-06-CHTSCREW000G39-10-16U (6)

GASKET167219-03-CHT(UNDER WOOD FLOOR)

1185

E-5

155

1100

E-1

VIEW A

VIEW B

DETAIL C(SHOWN W/OUT SHOWER)

DETAIL C

CP-26

GASKET167219-02-CHTUNDER WOOD FLOOR

280

STRAINER066440-01-000SEALANT084456-01-000

SHOWER INSTL180599-01-XXX

G-2

A-15

FLANGE167352-01-000SCREW087721-01-000(6)

GASKET167219-03-CHT(UNDER WOOD FLOOR)

SPACER166672-06-CHTSCREW000G39-10-16U (6)

ADAPTER-ANGLE165406-02-000

DETAIL E

DETAIL E

TRAP-WATERLESS165406-01-000

A-15

A-15

A-9 C-4

C-4

1625

1380

1525

11010

1160

1325

1320

1260

1175

1115

1140

1110

E-6

E-6

E-6

E-1

E-1

E-1

E-1

T-1

B-2 PL-1 155

E-53

S-2

S-2

C-3 A-10

N-1

C-3

155

W-7

7

7

CLAMP062401-02-000

CLAMP062401-02-000

*186563 *

9

9

W-7

TOILET160815-04-CHT

4100

ADAPTER-ANGLE165406-02-000

W-7

W-7

*186563 *

1100

24-Nov-2014

Page 3: AAVIEW A VIEW B DETAIL C (SHOWN W/OUT SHOWER) DETAIL C 6 CP-2 GASKET 167219-02-CHT UNDER WOOD FLOOR 2 80 STRAINER 066440-01-000 SEALANT 084456-01-000 SHOWER INSTL 180599-01-XXX G-2

A

2

C

DO NOT SCALE DRAWING

D

PART NO

C

DWGNO

1

REV

5

5

A

4

D

16

8

B

3

7

TITLE:

SHEET

8

3 2

7

6

4

B

FIRST USED

14 170A

3

186563

DRAINAGE SYSTEM INSTL

186563

TANK ASM-HOLDING180500-02-000

TANK ASM-HOLDING180552-02-000

C-2

E-13

2210

2175

N-3

E-3

HANDLE-EXTENTION062419-13-000 (2)HANDLE(USE HANDLE SUPPLIED WITH VALVE)

U-CHANNEL165872-01-CHT

BOLT-J091274-08-000 (6)NUT000D29-06-00U (6)WASHER000E13-18-00U (6)

GASKET167219-01-CHTUNDER WOOD FLOOR

1350

1170

SHIELD-HEAT,EXHAUST166164-07-CHT

VIEW D

SHIELD-HEAT,EXHAUST166164-08-CHTSCREW-SF/DR 10-16X.625 PPH000G39-10-10U (4)

H-1V-12

A-9

A-1

A-4

FOAM100619-B3-003

FOAM100619-B3-002

FOAM100619-B3-001FOAM

100619-B3-001

C-4

CHANNEL ASM-TANK179475-02-CHT

C-2

CP-1

E-11

FITTING-SPINWELD010232-01-000

1244

1009

1209

6

890

1389

DATUM

FRONTAXLE

VEHICLE

CHANNEL ASM-TANK179475-01-CHT

D

HANGLE-W/HOLE156309-05-CHT(2)SCREW000G39-10-10U(8)

CLAMP083610-02-000

275

FOAM100619-C1-001

ANGLE-SUPPORT168448-02-CHT

2220

*186563 *

ANGLE-SUPPORT187647-02-CHTCLAMP083610-02-000

*186563 *

24-Nov-2014

Page 4: AAVIEW A VIEW B DETAIL C (SHOWN W/OUT SHOWER) DETAIL C 6 CP-2 GASKET 167219-02-CHT UNDER WOOD FLOOR 2 80 STRAINER 066440-01-000 SEALANT 084456-01-000 SHOWER INSTL 180599-01-XXX G-2

A

2

C

DO NOT SCALE DRAWING

D

PART NO

C

DWGNO

1

REV

5

5

A

4

D

16

8

B

3

7

TITLE:

SHEET

8

3 2

7

6

4

B

FIRST USED

14 170A

4

186563

DRAINAGE SYSTEM INSTL

186563

KK

SECTION K-K

FF

SECTION F-F

JJ

SECTION J-J

123

32

DRILL 19 HOLETHROUGH FRAME MEMBER

DRILL 19 HOLETHROUGH FRAME MEMBER

DRILL 19 HOLETHROUGH FRAME MEMBER

119

25

24

119VIEW H

*186563 *

*186563 *

24-Nov-2014

Page 5: AAVIEW A VIEW B DETAIL C (SHOWN W/OUT SHOWER) DETAIL C 6 CP-2 GASKET 167219-02-CHT UNDER WOOD FLOOR 2 80 STRAINER 066440-01-000 SEALANT 084456-01-000 SHOWER INSTL 180599-01-XXX G-2

6

A

1

CHKR

DO NOT SCALE DRAWING

4

ONE-PLACE (X.X)

SHEET

7

REV

DWGNO

DFTR

1

MATERIAL:

DSNR

REV

TWO-PLACE (X.XX)

5

ZONE

A

ANGLE

6 5

8

REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES

WHOLE DIM (X)

4

REVISION RECORD

FIRST USEDM.E.

C

B

TITLE:

OF

C

DATE

3

DFTR-ORIG

2

THIRD ANGLE

D

REV

D

P.E.

ORIG. DATE

B

DATE

UNSPECIFIED TOLERANCES ARE:

COPYRIGHT 2014WINNEBAGO

INDUSTRIES, INC.

2 REF:

ALL DIMENSIONS ARE IN MILLIMETERS

8

PROJECTION

7

3

PART NO

A

14 170A

1.50.501

1 3

3

186564

WATER SYSTEM INSTL

RELEASE

186564

A

FRONTOF

COACH

29B WATER PURIFIER

501 WATER PURIFIER WITHOUT

53F WATER HEATER-ELEC IGNITION

53B WTR HTR-6 GAL ELEC/LP/GAS

CALLOUTSSEE DWG NO

116230-01-000

FORWATER

NOTES:

10 SECURE VALVE HANDLE W/SILICOLN

9 PARTS TO BE ASSEMBLED AND ABLE TO BE REMOVED AND STORED AS A SINGLE ASM.

8. ALL CRIMP FITTINGS TO 1/2" PEX TUBING REQUIRE 1/2" CLAMP 140171-03-000.

7. ALL CRIMP FITTINGS TO 5/8" PEX TUBING REQUIRE 5/8" CLAMP 140171-04-000.

6 LABEL HOT AND COLD SUPPLY TUBES AND TAPE FITTING TO TUBE BEFORE CABINET SET TO PREVENT MOVEMENT.

5 ADD PIPE WRAP (LADDER SCRAP 110157-02-000) INSULATION.

4 ADD TEFLON TAPE 010405-02-000.

3. ALL TUBING TO BE SECURED AT 1200 INTERVALS MAXIMUM WITH CLAMP 010495-01-000 AND SCREW 000G67-10-12B OR EQUIVALENT.

2. TUBING TO BE INSTALLED WITH SUFFICIENT SLOPE TO PROVIDE DRAINAGE TO NEAREST VALVE.

1. PLASTIC FITTINGS TO BE SEALED WITH SEALANT 084456-01-000.X-X

*186564 *

*186564 *

*186564 *

13-Nov-2014

Page 6: AAVIEW A VIEW B DETAIL C (SHOWN W/OUT SHOWER) DETAIL C 6 CP-2 GASKET 167219-02-CHT UNDER WOOD FLOOR 2 80 STRAINER 066440-01-000 SEALANT 084456-01-000 SHOWER INSTL 180599-01-XXX G-2

A

2

C

DO NOT SCALE DRAWING

D

PART NO

C

DWGNO

1

REV

5

5

A

4

D

16

8

B

3

7

TITLE:

SHEET

8

3 2

7

6

4

B

FIRST USED

14 170A

2

186564

WATER SYSTEM INSTL

186564

WATER HEATER051391-03-000145541-02-000DOOR125420-06-CHTCABLE076767-03-000SCREW000G39-10-169 (16)FLANGE-WATER HEATER180797-01-CHTADAPTER-BRASS136333-01-000CLOSEOUT ASM180780-01-CHT

FAUCET-LAV148886-02-CHT

S-1

PANEL-WATER PUMP149477-02-CHTSCREWG39-08-16U (4)FOAM140364-01-CHTSCREWG39-08-24U (4)

PW-5F-9

FILTER KIT KIT160946-03-000SCREW000G67-10-12U (2)

R-3

R-5600600

TO TOILET

V-6

501

44

SHOWER-EXTERIOR166291-01-CHTHOSE ASM-W/SPRAYER166291-02-000

TU10260

GROMMET071015-13-000

T-28

53B

TU-8380

53F

A-19

VIEW A

29B

29B

DETAIL B(SHOWN W/OUT SHOWER)

DETAIL B

T-29

E-44E-44

V-22

DETAIL G

DETAIL G

T-28

DETAIL H(SHOWN W/OUT SHOWER)

DETAIL H

T-28

T-29

T-28

T-28

T-28

E-46

E-44

E-44

E-43

E-43

E-43

R-2

A-27

FAUCET-GALLEY165378-02-CHT

R-2

V-11

WASHER-PLASTIC180671-02-CHT

GROMMET071015-13-000 (2)

TU10100

TU1040

TU10135TU10

95

TU10195

TU-980

TU-9245

TU-980

TU-965

TU-91375

TU101250

TU10110

TU-995

TU-9850

TU-8615

TU-91345

TU-9 40

TU-92980

TU103020

TU-8650

TU10330

TU-965

TU1065

TU1085

TU-985

VIEW J

T-28

E-46

T-28

E-43

TU10220

TU-9245

V-22

TU-955

TU10480

TU-9450

*186564 *

E-38

SHOWER-HAND HELD, WALL MOUNT187372-01-CHT

E-43

TU-955

*186564 *

*186564 *

V-72

A-282

13-Nov-2014

Page 7: AAVIEW A VIEW B DETAIL C (SHOWN W/OUT SHOWER) DETAIL C 6 CP-2 GASKET 167219-02-CHT UNDER WOOD FLOOR 2 80 STRAINER 066440-01-000 SEALANT 084456-01-000 SHOWER INSTL 180599-01-XXX G-2

A

2

C

DO NOT SCALE DRAWING

D

PART NO

C

DWGNO

1

REV

5

5

A

4

D

16

8

B

3

7

TITLE:

SHEET

8

3 2

7

6

4

B

FIRST USED

14 170A

3

186564

WATER SYSTEM INSTL

186564

TANK ASM-WATER,28 GAL165457-02-000

U-CHANNEL165872-03-CHT (3)BOLT-HOOK091274-08-000 (3)BOLT-HOOK091274-06-000 (3)WASHER000E13-18-00U (6)NUT000D29-06-00U (6)

U-CHANNEL165872-03-CHTBOLT-HOOK091274-08-000BOLT HOOK091274-06-000WASHER000E13-18-00U (2)NUT000D29-06-00U (2)

SHIELD ASM-EXHAUST166164-01-CHT S-1

S-1

E-21

T-29

TU-3230

TU-9855

TU-92100

9

TU-9905

NUT000D39-06-00U (3)TOP SIDE OFCHANNEL

F-13

TU-4800

A-4

NUT000D39-06-00UTOP SIDE OFCHANNEL

TUBE122737-51-088TAPE76322-02-000 (400)(TAPE TUBE TO TOP OF CHANNEL)

CLAMP-HOSE062401-01-000

PANEL-WATER CENTER167283-07-CHT

TU-9 65

TU-9130

GROMMET016188-10-000

GROMMET023942-01-000

DETAIL F

DETAIL F

VIEW C

WATER LINES AND TANKS UNDER FLOOR

F-5

TU-950

FILL-GRAVITY166288-01-CHT

C

VIEW E

T-28T-28

E-21

E-44

E-43E-43

E-43

E-43

E-43

E-43E-43

E-43

A-30

PANEL-GRAVITY FILL166584-03-CHTCLAMP062401-01-000 (2)

V-11

CLAMP010495-04-000 (2)RIVET113133-03-CHT (2)

E-43

TU-995

TU-960

TU-985

TU-995

TU-960

TU-9255

TU-9135

TU-9215

TU-9135

TU-940

TU-940

TU-950

TU-940

TU-945

TU-940

TU-940

E-43

TU-955

TU-945

E

TU-940

10

A-13

CH-5 9

E-35

*186564 *

9

CLAMP010495-04-000RIVET113133-03-CHT

V-233

*186564 *

E-46

TU-940

V-22

TU-940

E-46

*186564 *

13-Nov-2014